Details Drawings Collection

advertisement
details
Details
Individual drawings are available for download and insertion
into working drawings from our website, and from
www.caddetails.com (search: greenscreen).
Details
5132R WALL MOUNTED – PLAN & SECTION VIEW
5132R STEEL MOUNTED – PLAN & SECTION VIEW
5132G WALL MOUNTED – PLAN & SECTION VIEW
5132G STEEL MOUNTED – PLAN & SECTION VIEW
5159 STANDOFF BRACKET - PLAN & SECTION VIEW
CONTENTS
3-D BIM and SketchUp files are also available.
CORNER DETAIL - WALL MOUNTED
5133X POST MOUNTED
5141 C-CLIP TO POST OR SLAB
FREESTANDING HORIZONTAL
FREESTANDING VERTICAL
FREESTANDING CURVED
OVERHEAD PANEL - SURFACE MOUNT
OVERHEAD PANEL - INSET
COLUMN TRELLIS - STANDARD
COLUMN TRELLIS - WITH PLANTER
HEDGE-A-MATIC CURVED RECTANGULAR PLANTER
HEDGE-A-MATIC RECTANGULAR PLANTER
HEDGE-A-MATIC SQUARE PLANTER
FALL 2015
FIBERGLASS PLANTER
5135R PLANTER STRAPS
g re e n s creen ®
1743 S. La Cienega Blvd. Los Angeles CA 90035 T - 800.450.3494 www.greenscreen.com
*Fasteners and expansion anchors
by others.
5132R
Wall Mounted, Plan & Section MOUNTING CLIP
EXISTING CONCRETE OR
MASONRY WALL
At stucco and plaster locations clips
should be mounted into solid
blocking, sheathing or wall studs.
EXPANSION ANCHOR BY
OTHERS.
MINIMUM 480 LBS.
PULL OUT.
CLIP SIZED FOR 3/8” DIA.
FASTENER, TYP.
CL
NOTE: Mounting hole in clip is
sized for maximum 3/8” diameter
fastener.
#5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC,
TYP.
#5132R MOUNTING CLIP,
TYP.
3”
VARIES
3/4”2-1/4”
3” THICK greenscreen® PANEL,
TYP.
3-3/4” — 5-1/4”
#5132R MOUNTING CLIP - WALL MOUNTED
PLAN
EXISTING CONCRETE OR
MASONRY WALL
CL
EXPANSION ANCHOR BY
OTHERS.
MINIMUM 480 LBS.
PULL OUT.
CLIP SIZED FOR 3/8” DIA.
FASTENER, TYP.
#5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC,
TYP.
#5132R MOUNTING CLIP,
TYP.
3”
VARIES
3/4”2-1/4”
3” THICK greenscreen® PANEL,
TYP.
FALL 2015
3-3/4” — 5-1/4”
#5132R MOUNTING CLIP - WALL MOUNTED
SECTION
g re e n s c reen ®1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
SELF-TAPPING STAINLESS STEEL
TEK SCREW - 1/4” DIA. TYP.
CL
*Used for surface mounting panels to
steel support structures.
#5132R MOUNTING CLIP, TYP.
NOTE: Mounting hole in clip is sized
for maximum 3/8” diameter fastener,
1//4” diameter fastener is OK.
3”
VARIES
1/4”1-3/4”
3” THICK greenscreen®
PANEL, TYP.
3-1/4” — 4-3/4”
#5132R MOUNTING CLIP - STEEL MOUNTED
PLAN
EXISTING STEEL SUPPORT
STRUCTURE BY OTHERS
5132R
Steel Mounted, Plan & Section MOUNTING CLIP
EXISTING STEEL SUPPORT
STRUCTURE BY OTHERS
SELF-TAPPING STAINLESS STEEL
TEK SCREW - 1/4” DIA. TYP.
#5132R MOUNTING CLIP, TYP.
3”
VARIES
1/4”1-3/4”
3” THICK greenscreen®
PANEL, TYP.
#5132R MOUNTING CLIP - STEEL MOUNTED
SECTION
g re e n s c reen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
FALL 2015
3-1/4” — 4-3/4”
T - 800.450.3494 www.greenscreen.com
5132G
Wall Mounted, Plan & Section MOUNTING CLIP
EXISTING CONCRETE OR
MASONRY WALL
EXPANSION ANCHOR BY
OTHERS.
MINIMUM 480 LBS.
PULL OUT.
CLIP SIZED FOR 3/8” DIA.
FASTENER, TYP.
CL
#5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC,
TYP.
#5132G MOUNTING CLIP,
W/ BENT STEEL GUSSET @
ONE SIDE, TYP.
3”
5” — 6-1/2” (VARIES)
3” THICK greenscreen® PANEL,
TYP.
*Fasteners and expansion anchors by others.
VARIES 8” — 9-1/2”
FACE OF PANEL TO FACE OF WALL
*Used to hold panels off
face of wall or structure a
maximum of 9-1/2”.
#5132G MOUNTING CLIP - WALL MOUNTED
PLAN
EXISTING CONCRETE OR
MASONRY WALL
*At stucco and plaster
locations clips should be
mounted into solid
blocking, sheathing or
wall studs.
EXPANSION ANCHOR BY
OTHERS.
MINIMUM 480 LBS.
PULL OUT.
CLIP SIZED FOR 3/8” DIA.
FASTENER, TYP.
NOTE: Mounting hole in
clip is sized for
maximum 3/8” diameter
fastener.
CL
#5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC,
TYP.
#5132G MOUNTING CLIP,
W/ BENT STEEL GUSSET @
ONE SIDE, TYP.
3”
5” — 6-1/2” (VARIES)
3” THICK greenscreen® PANEL,
TYP.
VARIES 8” — 9-1/2”
FALL 2015
FACE OF PANEL TO FACE OF WALL
#5132G MOUNTING CLIP - WALL MOUNTED
SECTION
g re e n s c reen ®1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
* Used to hold panels off steel support or structure a maximum of 9”.
EXISTING STEEL SUPPORT
STRUCTURE BY OTHERS
SELF-TAPPING STAINLESS STEEL
TEK SCREW
1/4” DIA. @ STEEL, TYP.
CLIP HOLE SIZED FOR 3/8” DIA.
MAXIMUM
CL
#5132G MOUNTING CLIP,
W/ BENT STEEL GUSSET @
ONE SIDE, TYP.
3”
4-1/2” — 6” (VARIES)
3” THICK greenscreen® PANEL,
TYP.
VARIES 7- 1/2” — 9”
FACE OF PANEL TO FACE OF STRUCTURE
#5132G MOUNTING CLIP - STEEL MOUNTED
PLAN
EXISTING STEEL SUPPORT
STRUCTURE BY OTHERS
CL
5132G
Steel Mounted, Plan & Section MOUNTING CLIP
NOTE: Mounting hole in clip is sized for maximum 3/8” diameter
fastener, 1/4” diameter fastener is OK.
SELF-TAPPING STAINLESS STEEL
TEK SCREW
1/4” DIA. @ STEEL, TYP.
CLIP HOLE SIZED FOR 3/8” DIA.
MAXIMUM
#5132G MOUNTING CLIP,
W/ BENT STEEL GUSSET @
ONE SIDE, TYP.
3” THICK greenscreen® PANEL,
TYP.
4-1/2” — 6” (VARIES)
3”
#5132G MOUNTING CLIP - STEEL MOUNTED
FALL 2015
VARIES 7- 1/2” — 9”
FACE OF PANEL TO FACE OF STRUCTURE
SECTION
g re e n screen ®1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
*Used to hold panels off face of wall or structure a maximum of 18"
NOTE: Mounting hole in clip is sized for maximum 3/8” diameter fastener.
EXISTING CONCRETE OR
MASONRY WALL
1-1/2”
CL
(2) #5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC, TYP.
#5159 STANDOFF BRACKET,
W/ (2) 1/4” DIA. RODS WELDED TO
STEEL “L”, TYP.
WITH (2) MOUNTING HOLES
SIZED FOR 3/8” DIA. FASTENERS
3” THICK greenscreen® PANEL, TYP.
3”
6 -1/2” — 15”
(SPECIFY)
18” MAXIMUM
FACE OF PANEL TO FACE OF WALL
#5159 STANDOFF BRACKET - WALL MOUNTED
PLAN
4 - 1/2”
CL
(2) #5136 SPACER
1/2” X 1-1/2” DIA.
BLACK UHMW PLASTIC, TYP.
CL
6”
(2) 3/8” DIA. EXPANSION
ANCHORS BY OTHERS.
MINIMUM 480 LBS. PULL OUT
3/4”
EXISTING CONCRETE OR
MASONRY WALL
3/4”
5159
Standoff Bracket, Wall Mounted, Plan & Section MOUNTING CLIP
(2) 3/8” DIA. EXPANSION
ANCHORS BY OTHERS.
MINIMUM 480 LBS. PULL OUT
#5159 STANDOFF BRACKET,
W/ (2) 1/4” DIA. RODS WELDED TO
STEEL “L”, TYP.
WITH (2) MOUNTING HOLES
SIZED FOR 3/8” DIA. FASTENERS
3” THICK greenscreen® PANEL, TYP.
FALL 2015
3”
6 -1/2” — 15”
(SPECIFY)
18” MAXIMUM
FACE OF PANEL TO FACE OF WALL
#5159 STANDOFF BRACKET - WALL MOUNTED
SECTION
g re e n s c reen ®1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
* Most common panel to corner
configuration
EXISTING WALL, TYP.
#5132R OR #5132G MOUNTING CLIPS
W/ 5136 SPACER AND FASTENERS.
VERIFY TYPE AND QUANTITY
3”
+ 8”
Corner Detail
3” THICK greenscreen®
PANEL, TYP.
WALL MOUNTED
3/4” - 2-1/4” @ “R” CLIP LOCATIONS
5” - 6-1/2” @ “G” CLIP LOCATIONS
5105 TRIM @
OUTSIDE CORNER ONLY,
TYP.
3/4” - 2-1/4” @ “R” CLIP LOCATIONS
5” - 6-1/2” @ “G” CLIP LOCATIONS
+- 7” TYP.
CORNER DETAIL - WALL MOUNTED
FALL 2015
PLAN
g re e n screen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
*Only requires access to one face of panel
*Consult Mounting Options/ Freestanding Horizontal for maximum spans.
5133X
Snap Clip, Post Mounted MOUNTING CLIP
NOTE: Mounting hole in clip is sized for 1/4” diameter fastener.
5104 OR 5105 EDGE TRIM OPTIONAL
C
L
3” ROUND OR SQUARE STEEL POST
STAINLESS STEEL SELF-TAPPING
TEK SCREWS (2)
CLIP SIZED FOR 1/4” DIA. FASTENER,
TYP.
3” THICK greenscreen®
PANEL, TYP.
ADDITIONAL PANEL WHERE OCCURS,
TYP.
PLAN / SECTION
#5133X SNAP CLIP HOOK CLIP ON PANEL WIRE +
ROTATE UNTIL IT “SNAPS” INTO POSITION
5104 OR 5105 EDGE TRIM
OPTIONAL
#5137 ROUND / #5139 SQUARE POST
CAP/ WELDED FLAT CAP
1-3/4”
5”
#5104 CHANNEL TRIM
OR #5105 EDGE TRIM
OPTIONAL @ TOP EDGE
AND SIDES OF PANEL
#5133X SNAP CLIP
STAINLESS STEEL SELF-TAPPING
TEK SCREWS (2) PER CLIP
CLIP SIZED FOR 1/4” DIA. FASTENER,
TYP.
3” ROUND OR SQUARE STEEL POST
+- 1/2”
ELEVATION
FALL 2015
#5133X SNAP CLIP - POST MOUNTED
g re e n s c re en ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
#5105 STEEL EDGE TRIM REQUIRED
@ VERTICAL PANEL EDGES, TYP.
STAINLESS STEEL TEK SCREW OR
THRU-BOLT.
CLIPS SIZED FOR MAXIMUM 3/8” DIA.
FASTENER, TYP. - 1/4” DIA. OK.
CL
ADDITIONAL PANEL WHERE OCCURS
PLAN / SECTION
3” STEEL POST, OR LARGER
3” THICK greenscreen®
PANEL, TYP.
#5141 “C” CLIP
W/ STAINLESS STEEL TEK
SCREW OR THRU BOLT
#5104 CHANNEL TRIM OR
#5105 EDGE TRIM OPTIONAL
@ TOP EDGE OF PANEL
#5139 POST CAP
1 - 3/4”
(2) #5136.25 SPACERS 1/4” THICK X 1 -1/2” DIAMETER
BLACK UHMW PLASTIC, TYP.
STAINLESS STEEL TEK SCREW OR
THRU-BOLT.
CL
CLIPS SIZED FOR MAXIMUM 3/8” DIA.
FASTENER, TYP. - 1/4” DIA. OK.
1/2” TYP.
#5142 SPACER. 1/2” X 2-5/8” X 1-3/4”
BLACK UHMW PLASTIC, TYP.
#5105 STEEL EDGE TRIM REQUIRED @
VERTICAL PANEL EDGES, TYP.
ELEVATION
#5141 “C” CLIP - POST MOUNTED
3” THICK greenscreen® PANEL, TYP.
#5141 “C” CLIP W/ EXPANSION
ANCHOR BY OTHERS - MINIMUM
480 LBS. PULL OUT.
CLIPS SIZED FOR MAXIMUM 3/8”
DIA. FASTENER, TYP.
#5105 STEEL EDGE TRIM @ PANEL
EDGES (REQUIRED) WITH
MOUNTING CLIPS, TYP.
3” SQUARE STEEL POST, OR LARGER
5141
Wall Mounted, Plan & Section MOUNTING CLIP
#5142 SPACER. 1/2” X 2-5/8” X 1-3/4”
BLACK UHMW PLASTIC, TYP.
* Can be used with any size post.
* Requires #5105 edge trim @ panel
edges with clips.
NOTE: Mounting hole in clip is sized
for maximum 3/8” dia. fastener 1/4” dia. OK, with washer.
CONCRETE SLAB
SECTION
FALL 2015
(2) #5142 SPACERS for slab.
1/2” X 2-5/8” X 1-3/4”
BLACK UHMW PLASTIC, TYP.
#5141 “C” CLIP - SLAB MOUNTED
g re e n s c reen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
CL
3” THICK greenscreen®
PANEL, TYP.
PLAN
CL
POST TO POST CENTERS = PANEL LENGTH + 4”, TYP.
CL
HORIZONTAL PANEL MAXIMUM 96” IN 2’ INCREMENTS
POST TO POST CLEAR = PANEL LENGTH + 1”, TYP.
3” ROUND OR SQUARE
STEEL POST W/POST CAP,
TYP.
#5104 CHANNEL TRIM OR
#5105 STEEL EDGE TRIM,
RECOMMENDED AT TOP
EDGE OF PANEL, TYP.
48” MAXIMUM
PANEL HEIGHT
#5133X SNAP CLIPS W/
STAINLESS STEEL SCREW,
TYP.
PANEL TRIM OPTIONAL
WITH #5133X
OPTIONAL: 5141 “C” CLIP
W/ #5105 EDGE TRIM
REQUIRED @ VERTICAL EDGES
USE #5142 + #5136.25
SPACER
48” MAXIMUM
PANEL HEIGHT
FLEX “C” RINGS @ PANEL
TO PANEL SEAM @ 12” O.C.
OPTIONAL
3” THICK greenscreen®
PANEL, TYP.
#5105 STEEL EDGE TRIM
RECOMMENDED @
BOTTOM EDGE OF PANEL
VERIFY
FINISH GRADE
POST IMBED LENGTH &
FOOTING SIZE SHOULD BE
VERIFIED BASED ON OVERALL HEIGHT, WINDLOADS &
SOIL CONDITIONS.
VERIFY
+- 6”
VERIFY HEIGHT - PANELS SIZED IN 2” INCREMENTS
FENCE / SCREEN
Freestanding, Horizontal
CL
ELEVATION
FALL 2015
FREESTANDING HORIZONTAL — FENCE / SCREEN
g re e n s c re en ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
NOTE: SPECIFIC
ENGINEERING MAY BE
REQUIRED BASED ON SITE
SPECIFIC SOIL CONDITIONS,
LOCAL WIND LOADS, AND
VERTICAL HEIGHT OF
FENCE/SCREEN.
NOTE: VERIFY PANEL SPAN
AND CLIP SPACING FOR ALL
ROOFTOP INSTALLATIONS
AND ALL INSTALLATIONS
20’ ABOVE GRADE.
T - 800.450.3494 www.greenscreen.com
CL
CL
CL
POST TO POST CENTERS = PANEL LENGTH + 4”, TYP.
VERTICAL PANEL MAXIMUM 48” IN 2’ INCREMENTS
POST TO POST CLEAR = PANEL LENGTH + 1”, TYP.
+ / - EQUAL
#5104 CHANNEL TRIM OR #5105
EDGE TRIM RECOMMENDED AT TOP
EDGE OF PANEL
#5133X SNAP CLIPS W/ (2)
STAINLESS STEEL SCREW, TYP.
PANEL EDGE TRIM OPTIONAL WITH
#5133X SNAP CLIP
+ / - EQUAL
OPTIONAL: 5141 “C” CLIP
W/ #5105 EDGE TRIM REQUIRED
@ VERTICAL EDGES
USE #5142 + #5136.25 SPACER
3” THICK greenscreen® PANEL,
TYP.
+ / - EQUAL
#5105 STEEL EDGE TRIM
RECOMMENDED @ BOTTOM
EDGE OF PANEL
VERIFY
FINISH GRADE
POST IMBED LENGTH &
FOOTING SIZE SHOULD BE
VERIFIED BASED ON OVERALL HEIGHT, WINDLOADS &
SOIL CONDITIONS.
VERIFY
+- 6”
VERIFY VERTICAL HEIGHT
PANELS SIZED IN 2” INCREMENTS TO 168” MAXIMUM
3” ROUND OR SQUARE STEEL POST
W/POST CAP, TYP.
Freestanding, Vertical
3” THICK greenscreen® PANEL, TYP.
PLAN
FENCE / SCREEN
CL
ELEVATION
NOTE: SPECIFIC
ENGINEERING MAY BE
REQUIRED BASED ON SITE
SPECIFIC SOIL CONDITIONS,
LOCAL WIND LOADS, AND
VERTICAL HEIGHT OF
FENCE/SCREEN.
FALL 2015
NOTE: VERIFY PANEL SPAN
AND CLIP SPACING FOR ALL
ROOFTOP INSTALLATIONS
AND ALL INSTALLATIONS
20’ ABOVE GRADE.
FREESTANDING VERTICAL — FENCE / SCREEN
g re e n s creen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
3" THICK greenscreen®
PANEL, TYP.
#5105 STEEL EDGE TRIM
@ TOP & BOTTOM EDGE
OF EACH PANEL REQUIRED,
TYP.
PLAN
3" ROUND TUBE STEEL
w/POST CAP TYP.
#5105 STEEL EDGE TRIM
@ TOP & BOTTOM EDGE
OF EACH PANEL REQUIRED,
TYP.
HORIZONTAL CURVED PANEL SPAN
#5133X SNAP CLIPS
OPTIONAL: 5141 "C" CLIP
w/5105 EDGE TRIM (REQUIRED)
@ VERTICAL EDGES
USE 5142 + 5136.25 SPACER
3" THICK greenscreen®
PANEL, TYP.
PANEL HEIGHT
48" MAX.
48" MAX
PANEL HEIGHT
PANEL EDGE TRIM OPTIONAL
AT VERTICAL EDGE WITH
5133X SNAP CLIP
(2) PAIR #5141 "C" CLIPS @
PANEL TO PANEL SEAMS
OPTIONAL
3" ROUND TUBE STEEL POST
w/POST CAP, TYP.
VERIFY
VERIFY HEIGHT - PANELS SIZED IN 2” INCREMENTS
96” MAXIMUM IN 4” INCREMENTS
FINISH GRADE
POST IMBED LENGTH &
FOOTING SIZE SHOULD BE
VERIFIED BASED ON OVERALL HEIGHT, WINDLOADS &
SOIL CONDITIONS.
VERIFY
+- 6"
Freestanding, Curved
FENCE / SCREEN
STANDARD RADIUS
4', 5', 6', 8', 10', OR 12'
SPECIFY
FALL 2015
(2) #5141 “C” CLIP W/ STAINLESS
STEEL THRU-BOLT AND (2) 5142
SPACERS, TYP. @ PANEL SEAM
WITH #5105 TRIM CONNECTION
NOTE: SPECIFIC
ENGINEERING MAY BE
REQUIRED BASED ON SITE
SPECIFIC SOIL CONDITIONS,
LOCAL WIND LOADS, AND
VERTICAL HEIGHT OF
FENCE/SCREEN.
NOTE: VERIFY PANEL SPAN
AND CLIP SPACING FOR ALL
ROOFTOP INSTALLATIONS
AND ALL INSTALLATIONS
20’ ABOVE GRADE.
FREESTANDING CURVED — FENCE / SCREEN
g re e n s c re e n ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
5132R MOUNTING CLIP, TYP.
3” THICK greenscreen® PANEL, TYP.
CL
CL
Surface Mount
CL
3”
3 - 1/4”
CL
OVERHEAD PANEL
#5104 CHANNEL TRIM OR #5105
EDGE TRIM RECOMMENDED @
EXPOSED PANEL EDGE.
1/4”
1/4” STAINLESS STEEL
SELF-TAPPING SCREW, TYP.
EXISTING STEEL SUPPORT
STRUCTURE BY OTHERS
48” MAXIMUM HORIZONTAL SPAN TO NEXT SUPPORT
*Used to mount panels on top of horizontal overhead structure for
continuous plant coverage
g re e n screen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
FALL 2015
OVERHEAD PANEL - SURFACE MOUNT
T - 800.450.3494 www.greenscreen.com
STAINLESS STEEL SELF-TAPPING
TEK SCREW, TYP,
8” CLIP @ DBL PANEL
2” X 8” X 10 GAUGE THICK CUSTOM
CLIP. FINISH TO MATCH PANEL, W/
5/16” DIA. HOLE CENTERED.
48” O.C. MAXIMUM, TYP.
3 - 1/8”
OVERHEAD PANEL
Inset
5” CLIP @ SINGLE PANEL
3” THICK greenscreen® PANEL W/ #5105
EDGE TRIM @ FULL PERIMETER, OPTIONAL
+
_ 5/16”
2” X 2” STEEL ANGLE WELDED TO
STEEL STRUCTURE BY OTHERS, TYP.
ADDITIONAL PANEL WHERE OCCURS
48” MAXIMUM HORIZONTAL SPAN
CLEAR DIMENSION = PANEL WIDTH + CLEARANCES
FALL 2015
OVERHEAD PANEL - INSET
*Allows horizontal overhead panels to be mounted between structural
members.
g re e n s c re en ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
+
_ 12”
1” TRIM BAND @ TOP + BOTTOM OF
COLUMN TRELLIS, TYP.
ADJUSTABLE MOUNTING CLIP COLUMN TRELLIS TO POST
CLR.
+
_ 4”
FINISH GRADE / SLAB
ELEVATION
CL
SQUARE STEEL POST - VERIFY SIZE
FOR MOUNTING CLIP FABRICATION +
PANEL CLEARANCE, TYP.
ADJUSTABLE MOUNTING CLIPS W/
SELF TAPPING SCREW TO COLUMN.
MINIMUM (8) CLIPS PER COLUMN.
(4) CLIPS @ TOP + (4) CLIPS @
BOTTOM, TYP.
* Can also be mounted to
cylindrical fiberglass planter.
NOTE: Panels can be shipped
flat without 1” trim bands top &
bottom & can be opened and
closed around structure in field
adding #5131 flex “C” rings @
6” o.c. or dropped over the top
of structure as drawn if site
conditions allow.
Standard
3” THICK greenscreen® COLUMN
TRELLIS
COLUMN TRELLIS
* Requires center structural
support.
+
_ 12”
COLUMN TRELLIS HEIGHT
UP TO 168” IN 2” INCREMENTS
CL
ADD MINIMUM (4) CLIPS @
PLAN
MID-SPAN FOR TRELLIS UNITS OVER
96” LENGTH.
COLUMN TRELLIS HEIGHT
UP TO 168” IN 2” INCREMENTS
15 - 1/2”
STANDARD DIA.
CL
SQUARE STEEL POST - VERIFY SIZE
FOR MOUNTING CLIP FABRICATION +
PANEL CLEARANCE, TYP.
3” THICK greenscreen® COLUMN
TRELLIS
ADJUSTABLE MOUNTING CLIP COLUMN TRELLIS TO POST
1” TRIM BAND @ TOP + BOTTOM OF
COLUMN TRELLIS, TYP.
CLR.
POST IMBED LENGTH & FOOTING
SHOULD BE VERIFIED BASED ON
OVERALL HEIGHT, WIND LOADS &
SOIL CONDITIONS.
SITE SPECIFIC ENGINEERING MAY
BE REQUIRED.
SECTION
FALL 2015
+ 4”
FINISH GRADE / SLAB
CL
STANDARD COLUMN TRELLIS
g re e n s creen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
Planter mounted
COLUMN TRELLIS HEIGHT
UP TO 72” IN 2” INCREMENTS
1” TRIM BAND @ TOP OF COLUMN
TRELLIS, TYP.
3” THICK greenscreen® COLUMN
TRELLIS
1” TRIM BAND @ BOTTOM
W/ (4) 1” X 1” MOUNTING ANGLES,
W/ (4) NEOPRENE WELL NUTS W/
STAINLESS STEEL BOLTS +
WASHERS
PLANTER
22”
CL
18” DIAMETER X 22” TALL
FIBERGLASS PLANTER W/ (4) OPTIONAL ROLLING CASTERS
FINISH GRADE / SLAB
* Requires no center
structural support
+
_ 2”
COLUMN TRELLIS
CL
ELEVATION
18”
PLANTER
3” THICK greenscreen® COLUMN
TRELLIS
1” X 1” MOUNTING ANGLE,
W/ NEOPRENE WELL NUT +
STAINLESS STEEL BOLT + WASHER
PLAN
NOTE:
Soil volume = 2.4 cu.ft.
Planter, screen, hardware
without soil = 40 lbs.
Total approximate weight
w/ soil + plants = 110 lbs.
FIBERGLASS PLANTER
15 - 1/2”
STANDARD DIA.
CL
COLUMN TRELLIS HEIGHT
UP TO 72” IN 2” INCREMENTS
1” TRIM BAND @ TOP OF COLUMN
TRELLIS, TYP.
3” THICK greenscreen® COLUMN
TRELLIS
PLANTER
22”
CL
1” TRIM BAND @ BOTTOM
W/ (4) 1” X 1” MOUNTING ANGLES,
W/ (4) NEOPRENE WELL NUTS W/
STAINLESS STEEL BOLTS +
WASHERS
18” DIAMETER X 22” TALL
FIBERGLASS PLANTER W/ (4) OPTIONAL ROLLING CASTERS
+
_ 2”
FALL 2015
FINISH GRADE / SLAB
SECTION
STANDARD COLUMN TRELLIS
g re e n s c reen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
42” CURVED PANEL
FIBERGLASS PLANTER, TYP.
18” PLANTER
48” PLANTER
ELEVATION - TALL
SECTION
18”
PLAN
TER
2” LIP
PLAN
PLANTER BRACKET W/
BACKING PLATE AND
STAINLESS STEEL BOLTS,
NUTS & WASHERS @
PLANTER NOTCH
3” THICK greenscreen® Panel
W/ #5104 TRIM @
MOUNTING BRACKET AND
#5105 TRIM @ TOP AND
PARTIAL SIDES
3D VIEW
_ 2”
20” PLANTER +
42”
20” PANEL
42” CURVED PANEL
48” PLANTER
1/2” DRAIN
CONFIRM LOCATION
ELEVATION - SHORT
CURVED RECTANGULAR PLANTER WITH PANEL OPTIONS
ELEVATION, SECTION & PLAN
g re e n s c reen ®
(2) PANEL OPTIONS:
• 36” TALL W/ FLAT TOP
• 20” SHORT W/ FLAT TOP
FALL 2015
PLANTER RADIUS 93”
NOTE:
Soil volume = 5.5 cu.ft.
Planter, screen, hardware
without soil = 40 lbs.
Total approximate weight
w/ soil + plants = 144 lbs.
Flat Screen Top
+
_ 2”
1-1/2”
NOTE: FRONT AND BACK OF
PLANTER ARE CURVED,
SIDES ARE FLAT
HEDGE - A - MATIC
CURVED RECTANGULAR PLANTER
PLANTER BRACKET W/
BACKING PLATE AND
STAINLESS STEEL BOLTS,
NUTS & WASHERS @
PLANTER NOTCH
12”
58”
36” PANEL
3” THICK greenscreen® Panel
W/ #5104 TRIM @
MOUNTING BRACKET AND
#5105 TRIM @ TOP AND
PARTIAL SIDES
46” PANEL (46-1/4” ACTUAL)
3” THICK greenscreen® Panel
W/ #5104 TRIM @
MOUNTING BRACKET AND
#5105 TRIM @ TOP AND
PARTIAL SIDES
36” PANEL
+
_ 2”
12”
58”
PLANTER BRACKET W/
BACKING PLATE AND
STAINLESS STEEL BOLTS,
NUTS & WASHERS @
PLANTER NOTCH
NOTE: FRONT AND BACK OF
PLANTER ARE CURVED,
SIDES ARE FLAT
1-1/2”
48” RADIUS
@ CURVED TOP
FIBERGLASS PLANTER, TYP.
18” PLANTER
48” PLANTER
ELEVATION - TALL
18” PLANTER
2” LIP
Flat or Curved Screen Top
PLAN
SECTION
PLANTER BRACKET W/
BACKING PLATE AND
STAINLESS STEEL BOLTS,
NUTS & WASHERS @
PLANTER NOTCH
3” THICK greenscreen® Panel
W/ #5104 TRIM @
MOUNTING BRACKET AND
#5105 TRIM @ TOP AND
PARTIAL SIDES
46” PANEL (46-1/4” ACTUAL)
42”
20” PANEL
W/ FLAT OR CURVED TOP
_ 2”
20” PLANTER +
HEDGE - A - MATIC
RECTANGULAR PLANTER
W/ FLAT OR CURVED TOP
3D VIEW
48” RADIUS
@ CURVED TOP
48” PLANTER
1/2” DRAIN
CONFIRM LOCATION
FALL 2015
ELEVATION - SHORT
RECTANGULAR PLANTER WITH PANEL OPTIONS
ELEVATION, SECTION & PLAN
g re e n s c re en ®
NOTE:
Soil volume = 6.2 cu.ft.
Planter, screen, hardware
without soil = 41 lbs.
Total approximate weight
w/ soil + plants = 196 lbs.
(4) PANEL OPTIONS:
• 36” TALL W/ FLAT TOP
• 36“ TALL W/ CURVED TOP
• 20” SHORT W/ FLAT TOP
• 20” SHORT W/ CURVED TOP
15 -1/2’ DIA.
COLUMN
REMOVABLE TOP W/ SET
SCREWS
HEDGE - A - MATIC
SQUARE PLANTER
36” PANEL
3” THICK greenscreen® PANEL
W/ #5105 STEEL EDGE TRIM
W/ RADIUS .
TYP. @ TOP & BOTTOM
+
_ 2”
58”
(4) MOUNTING ANGLES PER
COLUMN W/ STAINLESS
STEEL BOLTS, NUTS &
WASHERS
1 -1/2”
NOTE: FRONT AND BACK OF
PLANTER ARE CURVED, SIDES
ARE FLAT
18” PLANTER
(2) PANEL OPTIONS:
• 36” TALL COLUMN TRELLIS
• 20“ SHORT COLUMN TRELLIS
14” DIA.
18” SQUARE
PLANTER
OPENING
WITH COLUMN
SIDE ELEVATION - TALL
FIBERGLSS PLANTER, TYP.
(4) MOUNTING ANGLES PER
COLUMN W/ STAINLESS
STEEL BOLTS, NUTS &
WASHERS
REMOVABLE TOP W/ SET
SCREWS
PLAN
15 -1/2” DIA.
3“ THICK greenscreen®
COLUMN PANEL W/ CURVED
#5105 TRIM TOP & BOTTOM
COLUMN
NOTE: SIDES OF PLANTER
ARE FLAT
1/2” DIA. DRAIN. CONFIRM
LOCATION
18” PLANTER
FRONT ELEVATION - SHORT
SQUARE PLANTER WITH COLUMN OPTIONS
ELEVATION & PLAN
g re e n s c reen ®
3D VIEW
NOTE:
Soil volume = 2.4 cu.ft.
Planter, screen, hardware
without soil = 25 lbs.
Total approximate weight
w/ soil + plants = 85 lbs.
FALL 2015
20” PLANTER 2”
42”
20” PANEL
NOTE: FRONT AND BACK OF
PLANTER ARE CURVED
23 -1/2”
FIBERGLASS PLANTER, TYP.
#5135 PLANTER STRAPS W/ BACKING
PLATE & STAINLESS STEEL BOLTS,
NUTS AND WASHERS, TYP.
3” THICK greenscreen® PANEL W/
#5105 STEEL EDGE TRIM @ TOP AND
(2) VERTICAL EDGES, TYP.
PLAN
NOTE: PANEL CAN BE MOUNTED AT
ANY LOCATION ALONG THE SIDE OF
THE PLANTER
48”
PLANTER + PANEL
3” THICK greenscreen® PANEL W/
#5105 STEEL EDGE TRIM @ TOP AND
(2) VERTICAL EDGES, TYP.
TALLER PANELS REQUIRE
ADDITIONAL SUPPORT
#5135R PLANTER STRAPS W/
BACKING PLATE & STAINLESS STEEL
BOLTS, NUTS AND WASHERS, TYP.
VERIFY
FIBERGLASS PLANTER, TYP.
TOP OF PLANTER TAPERS INWARD
1/4” FROM THE BASE/BOTTM.
30”
48”
+
_ 2”
VERIFY VERTICAL HEIGHT
PANELS ARE SIZED IN 2” INCREMENTS
UP TO 72” MAX.
FIBERGLASS PLANTER
* For use on rooftop gardens or other venues that
require containers or a changeable layout
NOTE:
Soil volume = 16 cu.ft.
Planter, screen, hardware without soil = 95 lbs.
Total approximate weight w/ soil + plants = 495 lbs.
DRAIN PLUG.
4”
FINISH GRADE OR SLAB
ELEVATION — FRONT
SIDE
FALL 2015
FIBERGLASS PLANTER
g re e n s c reen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
8”
21”
8”
3” THICK greenscreen® PANEL
W/ #5105 STEEL EDGE TRIM @
TOP & (2) VERTICAL EDGES, TYP.
5135R
Planter STRAPS
2”
NOTE:
See “FIBERGLASS PLANTER”
detail for more info.
Top of planter tapers inward
+/- 1/4” from bottom.
3” X 48” X 10GA. #5135R
PLANTER STRAP W/ (6)
MOUNTING HOLES
3”
2”
3”
2 -1/2” X 21” X 10GA. BACKING
PLATE.
SLIDE BACKING PLATE UP
INSIDE EDGE OF PANEL + BOLT
THRU TO PLANTER STRAP W/
(3) 1” X 3/8” DIA. STAINLESS
STEEL BOLTS, TYP.
25”
3”
10”
48”
BOLT PLANTER STRAPS TO SIDE
OF FIBERGLASS PLANTER W/(3)
2-1/2” X 3/8” DIA. STAINLESS
STEEL BOLTS SET IN BED OF
SILICONE CAULK, TYP.
#5136.25 SPACER BETWEEN
SIDE OF PLANTER + PLANTER
STRAP, TYP.
8-1/2”
REINFORCED SIDE OF
FIBERGLASS PLANTER
1” 3-1/2”
PLANTING SOIL BY OTHERS,
TYP.
FINISH GRADE/ SLAB
SIDE ELEVATION
FALL 2015
SECTION
5135R PLANTER STRAPS
g re e n s creen ® 1743 S. La Cienega Blvd. Los Angeles CA 90035
T - 800.450.3494 www.greenscreen.com
Download