GE Installation Guide Lighting Infusion LED Module TM 1000 Lumens 1500 Lumens 2000 Lumens 3000 Lumens SKU Product Description SKU Product Description SKU Product Description SKU Product Description 97184 M1000/827/W/N 97185 M1500/827/W/N 97192 M2000/827/W/N 97200 M3000/827/W/N 97186 M1000/830/W/N 97189 M1500/830/W/N 97193 M2000/830/W/N 97201 M3000/830/W/N 97187 M1000/930/W/N 97190 M1500/930/W/N 97194 M2000/930/W/N 97202 M3000/930/W/N 97188 M1000/840/W/N 97191 M1500/840/W/N 97199 M2000/840/W/N 97203 M3000/840/W/N SKU Product Description SKU Product Description 97204 OP1000/SP/W 64994 OP2000/3000/VWFL/W 97205 OP1500/SP/W 64995 OP2000/WFL/W 97206 OP1000/1500/WFL/W 64996 OP2000/3000/FL/W 97207 OP1000/1500/VWFL/W 97208 OP1000/1500/FL/W, OP3000/WFL/W Optics NOTE: LED Module 60 VDC, 1.4 amp maximum input. Only to be used with SELV driver. Wiring should not be put under excessive strain. BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING Risk of electrical shock. Disconnect power before servicing or installing product. A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out / tag out safety procedures. FOR YOUR SAFETY Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. Conforms to the following: imagination at work WARNING Risk of injury. While performing installations described, gloves, and safety glasses or goggles should be worn. PREPARE ELECTRICAL WIRING Electrical Requirements • DO NOT connect the LED Module directly to bench top power supplies without carefully considering the inrush current as this can damage the LED Module. • Only use a GE approved Class 2 (US/Canada) or SELV (Europe) driver that has been specified for use with the LED Module. • Wiring must be 2 wire with ground and rated for 75°C (176°F). • All electrical wiring should be preformed by qualified personnel and in accordance with local, state/province, and federal regulations. • The final fixture metal housing must be connected to earth ground. Components 1 LED fixture with InfusionTM module collar (may vary from illustration) 2 3 4 InfusionTM LED module InfusionTM module collar 1 2 3 4 InfusionTM optic LED fixture cover Installation GE Infu sion™ LED Module M 1 00 0/ 830/ W / N Lumen level on InfusionTM module (shown here in bold) 1 Remove the LED fixture cover from the LED fixture (if applicable). 2 Confirm the lumen level of the InfusionTM module matches the lumen level of the LED fixture. NOTE: The lumen level for the LED fixture will be listed on the product label or in the instructions. 3 Align the four tabs of the InfusionTM module with the corresponding grooves in the module collar. Insert and rotate the module clockwise 20 degrees to ensure proper engagement and seating of the module. NOTE: Risk of Breakage. Do not use excessive force to insert the module. Excessive force can cause the module to break. 1.5 Nm of torque typical to install. Do not exceed 5 Nm. 4 Attach the InfusionTM optic (if applicable) by aligning the three tabs of the optic with the corresponding grooves in the Infusion™ module. Insert and rotate clockwise until the optic is seated. (Process may vary for specialty optics supplied by the fixture manufacturer.) GE Lighting General Electric Company Nela Park Cleveland, OH 44112 Installation Instructions 5 Replace the LED fixture cover (if applicable). For additional product and application information, please visit www.gelighting.com/infusion 7/2011 Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. © 2011 GE