Infusion LED Module Installation Guide | GE Lighting

advertisement
GE
Installation Guide
Lighting
Infusion LED Module
TM
1000 Lumens
1500 Lumens
2000 Lumens
3000 Lumens
SKU
Product Description
SKU
Product Description
SKU
Product Description
SKU
Product Description
97184
M1000/827/W/N
97185
M1500/827/W/N
97192
M2000/827/W/N
97200
M3000/827/W/N
97186
M1000/830/W/N
97189
M1500/830/W/N
97193
M2000/830/W/N
97201
M3000/830/W/N
97187
M1000/930/W/N
97190
M1500/930/W/N
97194
M2000/930/W/N
97202
M3000/930/W/N
97188
M1000/840/W/N
97191
M1500/840/W/N
97199
M2000/840/W/N
97203
M3000/840/W/N
SKU
Product Description
SKU
Product Description
97204
OP1000/SP/W
64994
OP2000/3000/VWFL/W
97205
OP1500/SP/W
64995
OP2000/WFL/W
97206
OP1000/1500/WFL/W
64996
OP2000/3000/FL/W
97207
OP1000/1500/VWFL/W
97208
OP1000/1500/FL/W,
OP3000/WFL/W
Optics
NOTE: LED Module 60 VDC, 1.4 amp maximum input. Only to be used with SELV driver. Wiring should not be put under excessive strain.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
Risk of electrical shock. Disconnect power before servicing or
installing product.
A. Use this unit only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at the service
panel and follow appropriate lock out / tag out safety procedures.
FOR YOUR SAFETY
Read and observe all CAUTIONS and WARNINGS shown throughout
these instructions.
Conforms to the following:
imagination at work
WARNING
Risk of injury. While performing installations described, gloves,
and safety glasses or goggles should be worn.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• DO NOT connect the LED Module directly to bench top power supplies without carefully considering the inrush current as this can damage the LED Module.
• Only use a GE approved Class 2 (US/Canada) or SELV (Europe) driver that has been specified for use with the LED Module.
• Wiring must be 2 wire with ground and rated for 75°C (176°F).
• All electrical wiring should be preformed by qualified personnel and in accordance with local, state/province, and federal regulations.
• The final fixture metal housing must be connected to earth ground.
Components
1
LED fixture with InfusionTM module collar
(may vary from illustration)
2
3
4
InfusionTM LED module
InfusionTM module collar
1
2
3
4
InfusionTM optic
LED fixture cover
Installation
GE Infu
sion™ LED Module
M 1 00 0/ 830/ W / N
Lumen level on InfusionTM module
(shown here in bold)
1
Remove the LED fixture cover from
the LED fixture (if applicable).
2
Confirm the lumen level of the
InfusionTM module matches the
lumen level of the LED fixture.
NOTE: The lumen level for the LED
fixture will be listed on the product
label or in the instructions.
3
Align the four tabs of the InfusionTM
module with the corresponding
grooves in the module collar. Insert
and rotate the module clockwise
20 degrees to ensure proper
engagement and seating of the module.
NOTE: Risk of Breakage. Do not
use excessive force to insert the
module. Excessive force can cause
the module to break. 1.5 Nm of
torque typical to install. Do not
exceed 5 Nm.
4
Attach the InfusionTM optic (if applicable)
by aligning the three tabs of the optic
with the corresponding grooves in the
Infusion™ module. Insert and rotate
clockwise until the optic is seated.
(Process may vary for specialty optics
supplied by the fixture manufacturer.)
GE Lighting
General Electric Company
Nela Park
Cleveland, OH 44112
Installation Instructions
5
Replace the LED fixture cover
(if applicable).
For additional product and
application information, please visit
www.gelighting.com/infusion
7/2011
Information provided is subject to change without notice. Please verify all
details with GE. All values are design or typical values when measured under
laboratory conditions, and GE makes no warranty or guarantee, express or
implied, that such performance will be obtained under end-use conditions.
© 2011 GE