® Electrical - Power Fuses Bussmann Low-Peak® Dual-Element, Time-Delay, Class J Fuses LPJ_SP 600A 400A 125A 200A 250A 60A 80A 100A 30A 15A 10A 6A 3A AMPERE RATING TIME IN SECONDS 1A Time-Current Classification Curves—Average Melt Dual-Element, Time-Delay – 300 10 seconds (minimum) at 200 500% rated current 100 Ampere Ratings: 1-600A Voltage Rating: 600Vac (or less), 300Vdc (or less) 10 Current Limiting Interrupting Rating: ac – 300,000A RMS Sym. dc – 100,000A Agency Information: UL Listed - Special Purpose**, Guide JFHR, File E56412 1 CSA Certified (200,000 AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class J dimensional data. Catalog Numbers LPJ-200SP LPJ-2SP LPJ-7SP LPJ-45SP LPJ-225SP LPJ-2⁄Ω¢SP LPJ-8SP LPJ-50SP LPJ-250SP LPJ-2⁄Ω™SP LPJ-9SP LPJ-60SP LPJ-300SP LPJ-2°Ω¡ºSP LPJ-10SP LPJ-70SP LPJ-350SP LPJ-3SP LPJ-12SP LPJ-80SP LPJ-400SP .01 CURRENT IN AMPERES Current Limitation Curves LPJ-15SP LPJ-90SP LPJ-450SP LPJ-3⁄Ω™SP LPJ-17⁄Ω™SP LPJ-100SP LPJ-500SP LPJ Current Limitation Curves LPJ-4SP LPJ-20SP LPJ-110SP LPJ-600SP 100,000 Lbs. Kg. 10 1.09 0.49 35-60 10 1.78 0.81 70-100 5 1.69 0.77 110-200 5 4.21 1.91 225-400 1 1.67 0.76 450-600 1 2.80 0.27 *Weight per carton. Recommended fuseblocks/fuseholders for Class J 600V fuses • Open fuseblocks - see pages 53-55 • Finger-safe fuseholders for 30A & 60Asee pages 57-58 • Modular fuseblocks - see page 67 200A 100A 60A 10,000 30A 15A AMPERE RATING 0-30 Weight* Carton Qty. 1,000 A 100 1,000 Ampere Ratings B 600A 400A 100 Carton Quantity and Weight INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS LPJ-3¤Ω¡ºSP **Meets all performance requirements of UL Standard 248-8 for Class J fuses. Available with silver plated terminals. Add SP/ in front of part number. 10,000 LPJ-175SP LPJ-40SP 200,000 LPJ-35SP LPJ-6SP 300,000 LPJ-5flΩ¡ºSP LPJ-1°Ω¡ºSP 100,000 LPJ-1flΩ¡ºSP .1 1,000 LPJ-150SP 10,000 LPJ-125SP LPJ-30SP 100 LPJ-25SP LPJ-5SP 10 LPJ-4⁄Ω™SP LPJ-1⁄Ω¢SP 1 LPJ-1SP PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1006 (0-60) and 1007 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 17 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com ® Bussmann General Data – Dimensions (Inches) CLASS T CLASS J CLASS RK5 & RK1 T-Tron™ Fuses JJN (300V) JJS (600V) Low-Peak® & Limitron® Fuses LPJ & JKS (600V) Fusetron®, Low-Peak® & Limitron® Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLAG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. A B 250V Ampere ⁄Ω¡º-30 35-60 A 2∑ 3∑ 600V B .56∑ .81∑ A 5∑ 5.5∑ B .81∑ 1.06∑ A B Fusetron & Limitron 250V Ampere 70-100 110-200 225-400 450-600 A 5.88∑ 7.13∑ 8.63∑ 10.38∑ B 1.06∑ 1.56∑ 2.06∑ 2.59∑ 600V A 7.88∑ 9.63∑ 11.63∑ 13.38∑ B 1.34∑ 1.84∑ 2.59∑ 3.13∑ Low-Peak 250V Ampere 70-100 110-200 225-400 450-600 A 5.88∑ 7.13∑ 8.63∑ 10.38∑ B 1.16∑ 1.66∑ 2.38∑ 2.88∑ 600V A 7.88∑ 9.63∑ 11.63∑ 13.38∑ B 1.16∑ 1.66∑ 2.38∑ 2.88∑ CLASS L Low-Peak® & Limitron® Fuses KRP-C, KTU, & KLU (601 - 6000A) (600V) NOTE: KRP-CL (150A to 600A) fuses have same dimensions as 601A to 800A case size. KTU (200A to 600A) have same dimensions, except tube 3∑ lgth. ≈ 2∑ dia.; terminal 1fi/•∑ width ≈ 1⁄/¢∑ thick. 2 ® Bussmann General Data – Dimensions (Millimeters) CLASS T CLASS J CLASS RK5 & RK1 T-Tron™ Fuses JJN (300V) JJS (600V) Low-Peak® & Limitron® Fuses LPJ & JKS (600V) Fusetron®, Low-Peak® & Limitron® Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLAG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. A B 250V Ampere ⁄Ω¡º-30 35-60 A 50.8 76.2 B 14.3 20.6 600V A 127.0 139.7 B 20.6 27.0 A B Fusetron & Limitron 250V Ampere 70-100 110-200 225-400 450-600 A 149.2 181.0 219.1 263.5 B 26.9 39.6 52.3 65.8 600V A 200.0 244.5 295.3 339.7 B 34.0 46.7 65.8 79.5 Low-Peak 250V Ampere 70-100 110-200 225-400 450-600 A 149.2 181.0 219.1 263.5 B 29.5 42.2 60.5 73.2 600V A 200.0 244.5 295.3 339.7 B 29.5 42.2 60.5 73.2 CLASS L Low-Peak® & Limitron® Fuses KRP-C, KTU, & KLU (601 - 6000A) (600V) NOTE: KRP-CL (150A to 600A) fuses have same dimensions as 601A to 800A case size. KTU (200A to 600A) have same dimensions, except tube 76.2mm lgth. x 50.8mm dia.; terminal 41,3mm width x 31.8mm thick. 3