TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal Sheet VA, VF, and VS Series Direct Mounted Globe Valve Assemblies The Invensys VA, VF, and VS-XXXX-5XX series direct mounted, two-way and three-way globe valve assemblies are complete actuator/valve assemblies that accept two position, floating, or proportional control, respectively, from a DDC system or from a thermostat, for control of hot water, chilled water, and steam applications. These valve assemblies consist of spring return linear actuators direct mounted to 1-1/ 4" through 4" (32 mm through 100 mm) two-way and three-way globe valve bodies. An integrated rack and pinion translates the rotary motion of the actuator into the linear motion of the valve stem. Application Typical applications include hot and chilled water coils in air handling units, and unit ventilators. VX-7XXX-5XX Features • • • • ISO 9001 Certification Thermal isolation 3 ft. (91 cm) appliance cables, 1/2” conduit connectors NEMA 1 actuator enclosure. NEMA 2, UL Type 2 (IEC IP54) with customer supplied water tight conduit connectors • Overload protection throughout rotation • Visual position indicator • 250 psig valve body static pressure rating per ANSI Standards (B16.15—1985) for bronze bodies • 125 psig valve body static pressure rating per ANSI Standards (B16.15—1985) for cast iron flanged bodies • Tight close-off to ANSI III (0.1% of rated Cv) or ANSI IV (0.01% of rated Cv) • Valve sizes 1-1/4” to 4” • Spring-loaded TFE packing • Manual override mechanism VX-9XXX-5XX Printed in U.S.A. 3-03 F-27167 Specifications Valve Valve Application Valve Assembly Series Type of End Fitting Sizes Available 2-Way Valves 3-Way Valves Chilled water, hot water, steam Chilled water, hot water ❒ VX-7213-59X-4-P ❒ VX-7223-59X-4-P ❒ VX-7253-59X-4-P ❒ VX-7263-59X-4-P ❒ VX-7273-59X-4-P ❒ VX-7283-59X-4-P ❒ VX-9213-59X-4-P ❒ VX-9223-59X-4-P ❒ VX-9213-59X-5-P ❒ VX-9223-59X-5-P ❒ VX-7313-59X-4-P ❒ VX-7323-59X-4-P ❒ VX-9313-59X-4-P ❒ VX-9313-59X-5-P NPT NPT Flanged NPT NPT Flanged 1-1/4" to 2" 2-1/2" to 3" 2-1/2" to 4" 1-1/4" to 2" 2-1/2" to 3" 2-1/2" to 4" Action Stem up open, stem up closed Mixing, Diverting Material Body Bronze Cast iron Bronze Cast Iron Stem 316 stainless steel 303 stainless steel 316 stainless steel 303 stainless steel Packing Seat VX-7213, 7223, 9213, 9223, 93X3 VX-7253, 7263, 7273, 7283 Plug Disc Spring-loaded TFE Spring-loaded TFE Bronze Bronze Stainless steel VX-7213, 7223, 9213, 9223, 93X3 N/A Brass N/A N/A Bronze VX-7253, 7263, 7273, 7283 Stainless steel N/A N/A N/A VX-7213, 7223, 9213, 9223 Composition N/A N/A N/A N/A N/A VX-7253, 7263 Teflon N/A N/A VX-7273, 7283, 93X3 None N/A N/A ANSI Pressure Class 125 psig (862 kPa) up to 200 psig (1379 kPa) below 150 q F (66 q C) 250 psig (1727 kPa) up to 400 psig (2757 kPa) below 150 q F (66 q C) N/A None 250 psig (1727 kPa) up to 400 psig (2757 kPa) below 150 q F (66 q C) 125 psig (862 kPa) up to 200 psig (1379 kPa) below 150 q F (66 q C) Seat Leakage Class VX-7213, 7223, 7253, 7263, 9213, 9223 ANSI IV (0.01% of Rated Cv) VA-7273, 7283, 93X3 ANSI III (0.1% of Rated Cv) N/A N/A N/A ANSI III (0.1% of Rated Cv) Allowable Fluid Temperaturea 40 to 281 q F (4 to 138 q C) 20 to 300 q F (-7 to 149 q C) 40 to 300 q F (4 to 149 q C) VX-7213, 7223, 9213, 9223, 93X3 20 to 281q F (-7 to 138 q C) VX-7253-7263 20 to 340 q F (-7to 171 q C) N/A N/A N/A N/A VX-7273, 7283 20 to 366 q F (-7 to 186 q C) N/A N/A N/A N/A Maximum Steam Inlet Pressure VX-7213, 7223, 9213, 9223, 93X3 N/A N/A N/A VX-7253, 7263 100 psig (690 kPa) 35 psig (241 kPa) N/A N/A N/A N/A N/A VX-7273, 7283 150 psig (1034 kPa) N/A N/A N/A N/A N/A Allowable Differential Pressureb Water 35 psi (241 kPa) for normal life VX-7213, 7223, 9213, 9223, 93X3 Steam 35 psi (241 kPa) for normal life 20 psi (138 kPa) N/A N/A N/A VX-7253, 7263 35 psi (241 kPa) N/A N/A N/A N/A N/A VX-7273, 7283 50 psi (345 kPa) N/A N/A N/A N/A N/A a Do not apply above valve pressure rating to the piping system. b Maximum recommended differential pressure. Do not exceed the recommended differential pressure (pressure drop) or the integrity of valve parts may be affected. Exceeding the maximum recommended differential pressure voids the product warranty. 2 Specifications Actuator Inputs Control Signal Power Requirements ❒ MAX1-720X—On-off, SPST control contacts or Triacs (500 mA rated). ❒ MFX1-7203—Floating point control, 24 Vac. ❒ MSX1-7203—Proportional, 2 to 10 Vdc or 4 to 20 mAdc with 500: resistor. All 24 Vac circuits are Class 2. Circuits 30 Vac and above are Class 1. Running Part Number Connections Motor Type Mechanical Voltage 50/60 Hz 50 Hz Holding 60 Hz VA W VA W DC Amps 9.8 7.5 9.7 7.5 50 Hz 60 Hz W W 0.29 2.8 2.8 ❒ MAX1-7203 24 Vac ± 20% 22-30 Vdc ❒ MSX1-7203 24 Vac ± 20% 22-30 Vdc 9.8 7.4 9.7 7.4 0.28 2.9 2.9 ❒ MFX1-7203 24 Vac ± 20% 22-30 Vdc 9.8 7.7 9.7 7.7 0.30 3.3 3.3 ❒ MAX1-7200 120 Vac ± 10% 11.7 8.8 10.0 8.4 ❒ MAX1-7201 230 Vac ± 10% 15.5 9.5 10.6 8.5 — 3.6 5.0 4.6 3.3 3 ft. (91 cm) long, appliance cable. Brushless DC Linear Stroke: MX51-720X—5/8" (16mm). MX61-720X—1-1/16" (27 mm). Approx. Stroke Timing: 100 seconds for 5/8" stroke. 190 seconds for 1-1/16" stroke. Manual Override: Allows positioning of valve and preload using manual crank. Right/Left Switch: Permits reverse acting/direct acting linear motion (MSX1 only). Environment Ambient Temperature Limits Shipping & Storage: -40 to 160 q F (-40 to 71 q C). Operating: 0 to 140 q F (-18 to 60 q C) Temperature Restrictions: Actuator MX51-720X MX61-720X Max. Allowable Ambient @ Max. Fluid Temperatures Valve body 140 q F (60 q C)@ 281q F (138 q C) VB-721X, 722X 120 q F (49 q C) @ 300 q F (149 q C) VB-73XX 100 q F (38 q C)@ 340 q F (171 q C) VB-725X, 726X 90 q F (32 q C)@ 366q F (186 q C) VB-727X, 728X 140 q F (60 q C)@ 300q F (149 q C) VB-9XXX 2-1/2"-4" current production Humidity 15 to 95% RH, non-condensing Location NEMA 1, NEMA 2, UL Type 2 (IEC IP54) with customer supplied water tight conduit and connectors. Agency Listings UL 873: Underwriters Laboratories (File #E9429 Category Temperature-Indicating and Regulating Equipment). CUL: UL Listed for use in Canada by Underwriters Laboratories. Canadian Standards C22.2 No. 24-93. European Community: EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC) Australia: This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. 3 ( ) ( )( ) ( ) ( ) Direct Mounted Globe Valve Assembly Part Numbering System VX-XXXX-XXX-X-XX Control Signal Type A = Two Position F = Floating S = Proportional Connection Pattern Code 1 = Union Straightway 4 = Straightway 3 = Thread NPT or Flanged 5 = Globe Flanged Port Code Configuration 1 721, 921 = 2-Way, Stem Up Open 722, 922 = 2- Way, Stem Up Closed 2-Way 725 = 2-Way, NO (Stem Up Open) Stainless Steel Trim w/disc Size Cv 726 = 2-Way, NC (Stem Up Closed) Stainless Steel Trim w/disc 3-Way P Code Cv (Kvs) P Code 727 = 2-Way, NO (Stem Up Open) Stainless Steel Trim 1-1/4" (Kvs) 20 (17) 728 = 2-Way, NC (Stem Up Closed) Stainless Steel Trim 1-1/2" 28 (24) 731, 931 = 3-Way, Mixing 2" 40 (35) 11 41 (36) 732 = 3-Way, Diverting 2-1/2" 56 (48) 12 67 (58) - 65 (56) 12 74 b (64) - 12 85 (73) 13 91 (78) - 13 85 (73) 13 101 b (87) - 13 145 (125) 14 170 (147) - 14 3" Actuator Two Position MA51-7203=593 MA51-7200=592 MA51-7201=591 MA61-7203=596 MA61-7200=595 MA61-7201=594 Proportional MS51-7203=593 MS61-7203=596 4" Floating Mixing Diverting 9 20 (17) 20 9 10 28 (24) 28 10 40 11 a Threaded valve body b Flanged valve body a a 12 MF51-7203=593 MF61-7203=596 1 The configuration of the valve assembly determines the valve stem position and flow, as shipped from the factory. See the table below. Table-1 Valve Configuration Chart. Normal Position Valve Body Valve Body Action Action Valve Stem Flow VB-721X VB-7253 VB-7263 Two-Way Stem Up Open Up Open Port A to AB flow decreases as actuator extends VB-722X VB-7273 VB-7283 Two-Way Stem Up Closed Up Closed Port A to AB flow increases as actuator extends VB-731X VB-931X Three-Way Mixing Up B to AB Port A to AB flow increases as actuator extends Port B to AB flow deceases as actuator extends VB-732X Three-Way Diverting Up B to AB Port B to A flow increases as actuator extends Port B to AB flow decreases as actuator extends 4 Spring Return Models Note: Choose a valve assembly having a close-off pressure capability sufficient for the application. Table-2 Two-Way Direct Mounted Globe Valve Assemblies with Spring-Return Actuators — Selection Chart. Spring-Return Two-Way Direct Mounted Globe Valve Assemblies Actuator Torque Rating (minimum) 220 lbf (979 N) Two-Position MAX1-720X (591) (592) (593) (594) (595) (596) Floating MFX1-7203 (593) (596) Proportional MSX1-7203 (593) (596) Valve Assembly Part Number a VX-72X1-XXX-4-P VX-72X3-XXX-4-P VX-72X3-XXX-4-P VX-9213-XXX-4-P VX-9223-XXX-4-P VX-9213-XXX-5-P VX-9223-XXX-5-P P Code Valve Size in. Cv b kvsb Close-off Pressure psigcd 9 1-1/4 20 17 150 10 12 13 12 13 14 1-1/2 2-1/2 3 2-1/2 3 4 28 56 85 65 85 145 24 48 73 56 73 125 100 33 22 33 22 12 a To determine a specific part number, see the Direct Mounted Globe Valve Assembly Part Numbering System, kvs = m3/h ('P = 100 kPa) kvs = Cv / 1.156 Cv = kvs x 1.156 c Close-off ANSI IV (.01%) for soft seats. d Close-off pressure ratings describe only the differential pressure which the actuator can close-off with adequate seating force. Consult valve body specifications for other limitations. The rating value is the pressure difference between the inlet and outlet ports. b Table-3 Three-Way Globe Valve Assemblies with Spring-Return Actuators — Selection Chart. Spring-Return Three-Way Linked Globe Valve Assemblies Actuator Torque Rating (minimum) 220 lbf (979 N) Two-Position MAX1-720X (591) (592) (593) (594) (595) (596) Floating MFX1-7203 (593) (596) Proportional MSX1-7203 (593) (596) Valve Assembly Part Number a P Code VX-73X3-2XX-4-P 11 2 9 1-1/4 10 1-1/2 11 2 12 2-1/2 13 3 12 2-1/2 13 3 14 4 VX-73X3-XXX-4-P VX-9313-XXX-4-P VX-9313-XXX-5-P Valve Size in. Cvb kvsb Close-off Pressure psic 9 1-1/4 1-1/2 20 28 41 20 28 40 67 91 74 101 145 17 24 36 17.3 24.2 34.6 58 79 64 87 125 150 10 a 100 65 250 250 250 33 22 33 22 12 To determine a specific part number, see the Direct Mounted Globe Valve Assembly Part Numbering System. kvs = m3/h ('P = 100 kPa) kvs = Cv / 1.156 Cv = kvs x 1.156 c Close-off ANSI III (0.1%) for metal-to-metal seats with pressure at inlet (port A). For seat leakage ratings see “Applicable Literature” section for the list of literature on specific valve bodies. b 5 Dimensions Valve Dimensions in inches (millimetres) Valve Assembly Part Number 2-Way A VX-721X-59X-4-9 VX-722X-59X-4-9 VX-721X-59X-4-10 VX-722X-59X-4-10 VX-721X-59X-4-11 VX-722X-59X-4-11 4-5/8 (117) 5-3/8 (137) 6-1/8 (156) C E 1-3/8 (35) 8-11/16 (221) H 1-3/4 (44) 8-3/8 (213) 1-1/2 (38) 8-7/8 (225) 1-13/16 (46) 8-1/5 (216) 1-9/16 (40) 9-1/16 (230) 2-1/4 (57) 8-9/16 (217) 11-11/16 (297) 12-1/16 (306) 12-7/16 (316) Valve Dimensions in inches (millimetres) Valve Assembly Part Number 3-Way A C E H VX-731X-59X-4-9 4-5/8 (117) 1-7/8 (48) 8-3/8 (213) 11-11/16 (297) VX-731X-59X-4-10 5-3/8 (137) 1-5/8 (41) 8-1/2 (216) 12-1/16 (306) VX-731X-59X-4-11 6-1/8 (156) 1-15/16 (49) 8-9/16 (217) 12-7/16 (316) 10 9/16 (268) 2 9/16 (65) 4 1/16 (103) 6 15/16 (176) E C A H Minimum clearance: 5 inches for removal of the actuator. Figure-1 MX51-720X Spring Return Valve Actuator Dimensions. 6 Valve Dimensions in inches (millimetres) Valve Assembly Part Number 2-Way A C E H VX-92XX-59X-4-12 8-1/2 (216) 3-13/16 (97) 13-15/16 (354) 13-9/16 (344) VX-92XX-59X-4-13 9-1/2 (241) 4-1/4 (108) 14-1/4 (362) 13-5/8 (346) Valve Dimensions in inches (millimetres) Valve Assembly Part Number 3-Way A C E H VX-93XX-59X-4-12 8-1/2 (216) 4-5/8 (117) 13-15/16 (354) 13-9/16 (344) VX-93XX-59X-4-13 9-1/2 (241) 5 (127) 14-1/4 (362) 13-5/8 (346) 2 9/16 (65) 10 9/16 (268) 4 1/16 (103) 9 9/16 (243) E C A H Minimum clearance: 5 inches for removal of the actuator. Figure-2 MX61-720X Spring Return Valve Actuator Dimensions. 7 Valve Dimensions in inches (millimetres) Valve Assembly Part Number VX-9213-59X-5-12 2-Way Stem-Up Open Flanged Valve A C E F G H 8-1/2 (216) 3-1/2 (89) 13 (330) 7 (178) 5-1/2 (140) 13-5/8 (346) VX-9213-59X-5-13 9-1/2 (241) 3-3/4 (95) 14-1/2 (368) 7-1/2 (191) 6 (152) 14-1/8 (359) VX-9213-59X-5-14 11-1/2 (292) 4-1/2 (114) 15-3/8 (391) 9 (229) 7-1/2 (191) 15-1/8 (384) Valve Dimensions in inches (millimetres) Valve Assembly Part Number VX-9223-59X-5-12 2-Way Stem-Up Closed Flanged Valve A C E F G H 8-1/2 (216) 4 (107) 12-3/8 (314) 7 (178) 5-1/2 (140) 13-5/8 (346) VX-9223-59X-5-13 9-1/2 (241) 5 (127) 12-5/8 (320) 7-1/2 (191) 6 (152) 14-1/8 (359) VX-9223-59X-5-14 11-1/2 (292) 7-1/8 (181) 13-3/8 (340) 9 (229) 7-1/2 (191) 15-1/8 (384) Valve Dimensions in inches (millimetres) Valve Assembly Part Number VX-9313-59X-5-12 3-Way Stem-Up Open Flanged Valve A C E F G H 8-1/2 (216) 5-3/8 (137) 13-3/4 (349) 7 (178) 5-1/2 (140) 13-5/8 (346) VX-9313-59X-5-13 9-1/2 (241) 6-3/8 (162) 14 (356) 7-1/2 (191) 6 (152) 14-1/8 (359) VX-9313-59X-5-14 11-1/2 (292) 8-1/2 (216) 14-3/4 (375) 9 (229) 7-1/2 (191) 15-1/8 (384) 2 9/16 (65) 10 9/16 (268) 4 1/16 (103) 9 9/16 (243) E C G A F H Minimum clearance: 5 inches for removal of the actuator. Figure-3 MX61-720X Spring Return Flanged Valve Actuator Dimensions. All specifications are nominal and may change as design improvements are introduced. Invensys Building Systems shall not be liable for damages resulting from misapplication or misuse of its products. The following trademarks are the property of Invensys: Invensys DuraDrive F-27167 Printed in U.S.A.