HUBBELL LIGHTING The Mariner Stainless Steel Floodlight

advertisement
HUBBELL LIGHTING
The Mariner™ Stainless Steel Floodlight
UL LISTED AND CSA CERTIFIED
FOR MARINE AND HAZARDOUS ENVIRONMENTS
®
features &
benefits
FEATURES & BENEFITS
• Elevated Ambient Suitability
Meets requirements in high temperature environments
• “Restricted Breathing” listed
Provides lower, safer T-Ratings
• Superior Lighting Performance and High Wattage
Capability up to 1000W
Lowers installation and maintenance costs and improves
lighting with asymmetric distribution and higher efficiencies
• Marine Listed for hosedown capability and reliability,
American Bureau of Shipping (ABS) listed for
shipboard use
Multiple listings support broader range of applications
• Remote ballast 316 SS housing
Delivers high ambient capability (up to 65°C), high wattage,
minimal pole loading, reduced installed cost, and
performance reliability
• Universal Remote Head with adjustable lamp socket
Accepts various HID lamps, reducing inventory costs
• 800W MH Remote Ballast drives 2x400W MH
Remote Heads
Why Mariner?
Reduces installed cost
• Low EPA of 2.9 ft2
Minimizes pole loading, reducing installed cost
• Electro-Reg® and Pulse Start metal halide ballast systems
Rugged and tough.
Reduces installation, maintenance and operating costs
• Type 316 Stainless Steel Housing – 16 gauge
All 316 stainless steel.
Ensures low corrosion, long life, and durability,
reducing maintenance costs
• Rugged, quick release 316 SS Lens Latches
Versatile.
No hardware seizing or disassembly during relamping,
saving maintenance time and money
Only a screwdriver or blunt tool is needed
• 316 SS Safety Lens Door Chains
High ambient.
Enables hands-free relamping during electrical maintenance
Saves time, money, and provides safety
• 316 SS Mounting Yoke
Reliable, safe installation
Lower T-Ratings.
• Highly efficient (above 85%) photometrics
Excellent asymmetric/forward throw distribution
Minimizes number of required fixtures to deliver desired
Marine and Shipboard listed.
light levels, better uniformity and savings in energy costs
• 316 SS Cord Grip 1⁄ 2 " Connector (SFMM)
Provides watertight seal, corrosion resistant
Corrosion resistant.
• 316 SS Conduit Hub 3 ⁄ 4 " (SFM2/SFMH2/SSRB)
Lower costs.
• Hot-Dipped Galvanized Steel Mounting Accessories
Maintains grounding continuity
Provides watertight seal, corrosion resistant
Corrosion resistant in marine and corrosive environments
assuring reliable installation
The Mariner™
THE MOST VERSATILE, COMPLETE STAINLESS STEEL FLOODLIGHT IN THE INDUSTRY
Available in three styles:
SFMM for marine and non-hazardous environments
SFM2 for marine/Class I, Division 2 / Class I, Zone 2 environments
SFMH2/SSRB remote ballast box/remote head system
Each delivers:
• High ambient capability for improved performance and increased reliability in high
temperature applications
• Electro-Reg® and Pulse Start metal halide lamp source options – proven ballast technology
for reduced operating costs
• American Bureau of Shipping (ABS) listing – rated and ready for shipboard use
• High wattages and increased light levels – universal remote ballast capability provides
minimal pole loading, ease of installation
• Global voltages – floodlights for use almost anywhere in the world
• “Restricted Breathing” – means lower T-Ratings to meet hazardous location applications
• Superior optical performance
APPLICATIONS
applications
The Hubbell Lighting Mariner Flood
• Offshore production platforms
• FPSOs
•
• Refineries
•
• Offshore drilling rigs
•
• Barges
•
• Pulp and paper
•
• Ocean going vessels
• Commercial fishing vessels
is ideal for the following marine applications:
Jetties
Ports
Wharfs
Waste water and sewage treatment
Any type of marine, washdown, corrosive,
abrasive, or dirty environment where
dependable afloodlighting is needed
The Mariner is manufactured
under the ISO 9002 Quality
System Certification Program
More
LISTINGS
Rugged, yet
easy-to-open
316 SS
Latches.
No hardware
involved.
Two 316 SS
Lens Chains
allow
hands-free
maintenance
SFMM comes
with 316 SS
Cord Grip.
SFM2 comes
with 316 SS
Conduit Hub.
SFMM
•ANSI/UL 1572 HID Fixtures for
Marine Outdoor and Wet Locations
•CSA C22.2 9.0-96 General Requirements
•Type Approval American Bureau of Shipping (ABS)
•IP66/67
•NEMA 4X
SFM2/SFMH2/SSRB
•ANSI/UL 844 Hazardous Locations
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Groups IIC, IIB, IIA*
•CSA C22.2 137-M1981 Hazardous
Locations Class I, Division 2, Groups
A, B, C, D
Class I, Zone 2, Groups IIC, IIB, IIA*
ExnR, AxnR Restricted Breathing
(SFM2/SFMH2)
•ANSI/UL 1572 HID Fixtures for
Marine Outdoor and Wet Locations
•Type Approval American Bureau of Shipping (ABS)
•IP66/67
•NEMA 4X
listin
* Safe installation of light fixtures in Class I, Division 2/Zone 2
classified areas depends on many factors, including operating
temperature ratings. See T-Rating charts.
e Power. More Perf
DIMENSIONS: SFMM, SFM2, SFMH2
18.3"
(465mm)
CATALOG LOGIC (INTEGRAL BALLAST 150W - 400W)
8.6"
(220mm)
19.7"
(500mm)
25.2"
(640mm)
11.0"
(279.4mm)
4.2"
(106.3mm)
10.16"(258.06mm)
Center Hole
0.88"
(22.2mm)
1.5"
(39.75mm)
10.8"
(274.3mm)
2 Holes
0 56"
(14.3mm)
2.0"
(50.8mm)
3.1"
(79.5mm)
ENTRY
SFMM: 1/2" CORD GRIP
SFM2: 3/4" CONDUIT HUB
X
X
XX
Series
Wattage
Lamp Type
Voltage
Options
SERIES
SFMM Stainless Flood Marine
SFM2
Stainless Flood Marine
Class I, Division 2
VOLTAGE
55
480V
6
Tri-Tap® (120/277/347V)
8
Quad-Tap®
(120/208/240/277V)
E
220/240V, 50 Hz
P
220V, 60 Hz
WATTAGE
15
150W HPS, PS
17
175W MH, MV
5
25
250W HPS, MH, MV, PS
40
400W HPS, MH, MV, PS
OPTIONS
F(X)1,2,3 Fusing (X indicates voltage)
RS
Hot Re-Strike (150W HPS)
QS4
Quartz Standby
PCR(X)1,2,3,4 Photo Control
EA6
Elevated Ambient (40°C, 55°C,
65°C) capabilities, see chart
for applicable wattages
RB
Restricted Breathing Housing
allowing lower T-Ratings
for SFM2 Series only. Fixture
provided with test port entry
on side.
1 To specify correct voltage, replace X with
1-120V, 2-208V, 3-240V, 4-277V, 5-480V,
6-347V.
2 Not UL 1572 Marine Outdoor Listed.
3 Fixture not CSA listed with these options.
4 Available in SFMM only. Not suitable for
hazardous locations.
5 250W Pulse Start not available in 480 volt.
6 See table for Supply Wire Ratings
SFMM/SFM2
INTEGRAL BALLAST SUPPLY WIRE RATINGS
(SUFFIX “EA”)
SFMM/SFM2*
INTEGRAL BALLAST AMBIENT SUITABILITIES & T-RATINGS*
(SUFFIX “EA”)
175W MH
250W MH, PS
400W MH, PS
AMBIENT TEMPERATURE
40°C
55°C
65°C
90°C
110°C
90°C
110°C
110°C
—
110°C
—
—
150W HPS
250W HPS
400W HPS
90°C
90°C
110°C
90°C
110°C
—
110°C
—
—
175W MV
250W MV
400W MV
90°C
90°C
110°C
110°C
110°C
—
110°C
—
—
WATTAGE/LAMP TYPE
XX
LAMP TYPE
H
Metal Halide
S
High Pressure Sodium
C
Mercury Vapor
W
Pulse Start (PS) Metal
Halide (lamp included)
2.0"
(50.8mm)
20.2"
(513mm)
SFMM
WATTAGE/
LAMP TYPE
T-RATINGS & AMBIENT TEMPERATURE
40°C
55°C
65°C
CLASS I
DIV 2/
ZONE 2
CLASS I
ZONE 2
ExnR
AExnR
CLASS I
DIV 2/
ZONE 2
CLASS I
ZONE 2
ExnR
AExnR
CLASS1
DIV 2/
ZONE 2
CLASS I
ZONE 2
ExnR
AExnR
T1
T1
T1
T1
T4
T4
T3
T3
T1
T1
T1
—
T3
T3
T1
—
T1
T1
—
—
T3
T3
—
—
150W HPS
250W HPS
400W HPS
T2A/T2
T1
T1
T4
T3
T3
T2
T1
—
T4
T3
—
T2
—
—
T3
—
—
175W MV
250W MV
400W MV
T1
T1
T1
T4
T3
T3
T1
T1
—
T4
T3
—
T1
—
—
T3
—
—
150W
175W
250W
400W
PS
MH
MH, PS
MH, PS
* For standard SFM2 (less suffix EA), apply T-Ratings from 40°C column above.
gs
formance. More Ve
CATALOG LOGIC (REMOTE HEAD 350W - 1000W)
ADJUSTABLE LAMP SOCKET
SFMH2
XX
XX
Series
Entries
SERIES
SFMH2 Stainless Steel Remote Head,
Class I, Div. 2 Marine
ENTRIES
3/4" Conduit Hub
C1
C2
20mm Conduit Hub
3/4" Conduit Hub
C3
Restricted Breathing
C4
20mm Conduit Hub
Restricted Breathing
Lamp Type
LAMP TYPE*
UH
Universal Head
350W Pulse Start
400W HPS, MH,
Electro-Reg,® Pulse Start
1000W HPS
HH
1000W MH
* Mandatory to designate for listed light
sources. Lamps not included.
Universal head provides adjustable lamp socket which allows
multiple lamp flexibility
CATALOG LOGIC (REMOTE BALLAST 350W - 1000W)
SSRB
XX
XXXX
X
X
XX
Series
Entries
Wattage
Lamp Type
Voltage
Options
SERIES
SSRB
Stainless Steel Remote Box,
Class I, Div. 2 Marine
Class I, Div 2/Zone 2 Marine
ENTRIES
3/4" Conduit Hub
C1
C2
20mm Conduit Hub
WATTAGE
0350
350W Pulse Start only
0400
400W HPS. MH, PS, E-Reg
0800
One ballast for two
400W MH remote heads
(120/277V, 480V only)
1000
1000W HPS, MH
LAMP TYPE
E
Electro-Reg® Metal Halide
(400W only)
H
Metal Halide
S
High Pressure Sodium
W
Pulse Start (PS) 350/400W
SSRB 316SS remote ballast
box with reversible door
DIMENSIONS: SSRB
20.0"
(508mm)
1 To specify correct voltage, replace X with
1-120V, 2-208V, 3-240V, 4-277V, 5-480V,
6-347V. Fixtures with Fusing option will not
be UL 1572 Marine Outdoor certified, as
the UL 1572 spec does not allow marine
listing of fixtures with fusing. Fixtures with
Fusing not CSA listed.
WATTAGE
350W PS*
400W MH
0.62" diameter
(16mm)
9.25
(235mm)
6.0
(152mm)
11.25
(286mm)
OPTIONS
F(X)1
Fusing (X indicates voltage)
SSRB MOUNTING DISTANCES
6.63"
(168mm)
15.25"
(387mm)
VOLTAGE
1
120V (for Electro-Reg only)
2
208V (for Electro-Reg only)
3
240V (for Electro-Reg only)
4
277V (for Electro-Reg only)
5
480V
6
Tri-Tap® (120/277/347V)
8
Quad-Tap®
(120/208/240/277V)
9
120/277V 60 Hz
(for Dual 400W MH only)
E
220/240V, 50 Hz
F
347V (for Electro-Reg only)
P
220V, 60 Hz
400W
400W
400W
800W
PS*
E-REG
HPS
MH
1000W MH
Supply wire rating is 90°C
1.5"
(38mm)
1000W HPS
* Consult factory for mounting distances longer than 15'
MAX. DIST. (ft.)
15*
75
(#14 wire)
125
(#12 wire)
15*
15
50
75
(#14 wire)
125
(#12 wire)
125
(#14 wire)
205
(#12 wire)
75
PHOTOMETRICS
WATTAGE/
LAMP TYPE
T-RATINGS & AMBIENT TEMPERATURE
40°C
55°C
65°C
CLASS I
DIV 2/
ZONE 2
350W PS
400W MH, PS
400W E-REG
1000W MH*
400W HPS
1000W HPS
T1
T1
T1
T1
T1
T1
CLASS I
ZONE 2
ExnR
AExnR
T3
T3
T3
T2
T3
T2
CLASS I
DIV 2/
ZONE 2
T1
T1
T1
T1*
T1
T1
CLASS I
ZONE 2
ExnR
AExnR
T3
T3
T3
T2*
T3
T2
CLASS1
DIV 2/
ZONE 2
T1
T1
T1
—
CLASS I
ZONE 2
ExnR
AExnR
T3
T3
T3
—
T1
T1
T3
T2
* 1000W MH has maximum ambient capability of 50°C.
10
60
3
12
1
1
1
34
6
2
1
213 203 177 144 78
28
3
1
847
405 391 352 277 146 56
10
1
1638
2927
33
465
50
40
750 718 647 485 234 75
17
1
950 957 893 642 279 87
22
1
889 937 883 627 255 85
25
1
81
26
1
319 314 283 223 146 79
26
1
258 243 207 170 125 72
24
1
297 283 223 159 107 61
19
228 214 186 140 91
49
13
1
922
188 187 105 101 50
35
7
1
674
32
56
16
20
10
16
2
1
153
22
18
16
8
4
4
1
73
7
8
5
3
3
1
1
28
30
20
32045
10
23490
0
17219 573 592 556 403 186
12622
9253
10
20
9253
30
3645
40
60
70
80
WATTAGE
150/175W HPS, MH, PS
250W MH, PS
250W HPS
400W MH, PS
400W HPS
—
350 PS
400 MH, PS
400 HPS
400 E-REG
800W MH
1000W MH
1000W HPS
WEIGHT
42 lbs.
44 lbs.
46 lbs.
47 lbs.
49 lbs.
35 lbs.
32 lbs.
32 lbs.
34 lbs.
47 lbs.
49 lbs.
41 lbs.
48 lbs.
5286 5223 4668 3478 1749 736 199 12
VERTICAL TOTALS
80 70 60 50 40 30 20 10 0 10 20 30 43 50 60 70 80 90
TEST NO.:
SOURCE:
LAMP:
LAMP WATTS:
LCL:
BEAM
FIELD
HP-07477
HPS
ED-18 clear
400
5.75"
2418
1391
1100
1149
21,351
LUMENS:
IES/NEMA TYPE:
MAX. BEAM CANDLEPOWER:
AVG. MAX. CANDLEPOWER:
TOTAL EFFICIENCY:
50,000
6H X 6V
36,447
32,045
85%
HORIZONTALLY
VERTICALLY
LUMENS
EFFICIENCY
81.8
118.4
41.0
118.6
22,196
40,591
44%
81%
AXIAL CANDELA TRACES
31999
28799
25600
LUMINOUS INTENSITY - CANDELA
1 Not UL 1572 Marine Outdoor listed.
2 Available in SFMM only. Not suitable for hazardous locations.
3702
ANGLE FROM BEAM AXIS (DEGREES HORIZONTAL)
ACCESSORIES
Catalog No. Description
4024C-M38 Hot-Dipped Galvanized Steel Slipfitter for 2" pipe (23⁄8" O.D.) tenon,
includes hardware
4040-M38 Hot-Dipped Galvanized Steel Wall/Pole Bracket, includes hardware
4090-M38 Hot-Dipped Galvanized Cross Arm Fitting for horizontal trunnion,
includes hardware
PTL11,2
Photocontrol - Twist-Lock® Cell 120V
1,2
PTL8
Photocontrol - Twist-Lock Cell 120-277V
PTL51,2
Photocontrol - Twist-Lock Cell 480V
PTL61,2
Photocontrol - Twist-Lock Cell 347V
PSC1,2
Photocontrol Shorting Cap -Twist-Lock Mount (completes circuit)
1
SFM-LR
⁄8" diameter, 3' Steel Safety Cable, Hot-Dipped Galvanized
3831
6783
4972
50
WEIGHTS
DESCRIPTION
SFMM/SFM2
SFMM/SFM2
SFMM/SFM2
SFMM/SFM2
SFMM/SFM2
SFMH2 Remote Head
SSRB
SSRB
SSRB
SSRB
SSRB
SSRB
SSRB
5
145 99 107 71
70
HORIZONTAL TOTALS
SFMH2
REMOTE HEAD AMBIENT SUITABILITIES & T-RATINGS
LUMEN DISTRIBUTION
80
ANGLE FROM BEAM AXIS (DEGREES VERTICAL)
ersatility.
AVERAGE OF RIGHT-LEFT SIDES
ISO CANDELA CURVES
22400
19200
16000
12800
9600
6400
4024C-M38
(includes hardware)
4040-M38
(includes hardware)
4090-M38
(includes hardware)
3200
0
90
70
50
30
LEFT/DOWN
VERTICAL - HEAVY LINE
PTL
PSC
10
10
DEGREES
30
50
70
90
UP/RIGHT
HORIZONTAL - THIN LINE
HUBBELL LIGHTING’S FULL LINE OF
ENVIRONMENTAL LIGHTING
EWL
SSHZ
HLF
PERFORMER
N4E
N4E
KEMLUX
KEMLUX
HLEZ
NVQ
HLMB
HLE
HUBBELL LIGHTING, INC.
2000 Electric Way
Christiansburg, VA 24073-2500
PHONE: (540) 382-6111
FAX: (540) 382-1526
VISIT OUR WEB SITE:
HUBBELL CANADA, INC.
870 Brock Road South
Pickering, Ontario L1W 1Z8
PHONE: (905) 839-1138
FAX: (905) 839-9108
www.hubbell-ltg.com
© HUBBELL INCORPORATED
Printed in USA DECEMBER 2000
HAZ-030 R