Angelantoni Industrie S.p.A. - Steril Division Export Office Via Achille Grandi 16, 20017 Mazzo di Rho (MI) – ITALY +39 02 939 701 43 / +39 02 939 701 21 Head Quarter Località Cimacolle 464 – 06056 Massa Martana (PG) - ITALY +39 075 489551 +39 075 8955200 MVF LAF MODULAR SYSTEM ARTICLE DESCRIPTION MVF2 basic module HMVF2 half module MVF3 module CODE 00260000000 00276000000 00284900000 Introduction The MVF modules can be variously assembled together to build-up small to room size clean work areas. The basic module is a self-contained unit including HEPA filter and fan for delivering class ISO 5 air quality, accordiing to norm ISO EN 14644-1 and can be assembled according to the needs of the clean area configuration. The modules bolted together form a network structure to get a stiff assembling. Composition of the system The dimensions of the unit are the following: HMVF 680 mm 680 mm 500 mm Depth Length Height MVF2 1360 mm 680 mm 500 mm Depth Length Height MVF3 Depth Length Height 985 mm 985 mm 500 mm Main characteristics • • • • • TD_MVF_08.doc Rev. January 08 Made of Stainless Steel AISI 304 L with scotch brite finishing; Diffusion and Protection Grid for pre-filter and HEPA Filter in anodised aluminium; Modules MVF2 and MVF3 have a double intake fan rated to deliver 1.200 Nm³/h at air velocity of 0,45 m/s and at max. pressure of 320 Pascal; Module HMVF has a double intake fan rated to deliver 550 Nm³/h at air velocity of 0,45 m/s and at max. pressure of 320 Pascal; Improved design plenum in negative pressure to prevent risk that contaminated air might escape Pag. 1 • • • • • • • • • by-passing filter and to reduce pressure transition losses, noise level and uneven air velocity profile; Outlet for D.O.P. testing; Differential manometer outlet; Differential pressure switch in each module; Module MVF2 has a HEPA filter rated at 99,995% MPPS (0.3 micron) efficiency (H14 according to EN 1822), with dimensions 610x1220x66 mm; Module HMVF has a HEPA filter rated at 99,995% MPPS (0.3 micron) efficiency (H14 according to EN 1822), with dimensions 610x610x66 mm; Module MVF3 has a HEPA filter rated at 99,995% MPPS (0.3 micron) efficiency (H14 according to EN 1822), with dimensions 915x915x66 mm; All MVF modules are provided of prefilter G 3 according EN 779. Electrical supply 230 V/50 Hz monophase; Maximum power consumption for each module 620W; Control panels Remote control panel • AISI 304 stainless steel • IP 55 protection degree • Overall dimensions 600 x 600 x 250 (WxDxH) • General switch with door lock device; • “ON” (LAF) press button; • “OFF” (LAF) press button; • ON/OFF push button for the fluorescent lamp; • Alarm mute press button; • Green light of the laminar air flow (if green light flashes the air flow is irregular); Jolly control set (ABS material) • Ventilation (LAF) On/Off • Light On/Off • Fan velocity manual adjusting trimmer • Available on the panel remote Norms and directive The MVF Modules are designed according to the following standards and directives: • EN 60204-1 • LVD-Directive 72/23/EEC-93/68/EEC IMPORTANT !! The system we produce, according to the above statements, are manufactured in compliance with the laws on safety into force. Particularly, it is manufactured in compliance with Art. 6 Dlgs 626/94 and its modification (Italian law in compliance with European Directive EEC 89/391) on the DUTY OF DESIGNERS, OF MANUFACTURERS, OF SUPPLIERS AND INSTALLATORS. The system is NOT submitted to the directive EEC 93/42 on Medical Devices, as indicated in the definition of “Medical Devices” reported in art. 1 point 2a of the Directive mentioned. STERIL IS NOT responsible for damages to people and objects due to a non proper use of the system, and due to a fail to comply with the user instructions and maintenance that is always supplied with the system. Performances • • Air velocity measured at a distance of 300 mm: 0.45 m/s ± 10%; Contamination Class of the area under the laminar airflow: ISO 5 in “as built” conditions, according to norm ISO EN 14644-1. TD_MVF_08.doc Rev. January 2004 Pag. 2 Tests control In our Quality Control Dept., according to our procedure WI-MFG-006 included in the Quality manual of Steril Equipment Division. The Quality System of Steril S.p.A. Equipment Division is certified in compliance to EN ISO 90012000 with a Certificate n° CERT-00669-95-AQ-MIL-SINCERT/B released by “DNV – Det Norske Veritas”. On request, validation tests at site with IQ/OQ protocols are available. COMISSIONING (on request) STERIL will carry out the start-up at Client’s site with the following controls: • check of the laminar air flow velocity; • check of the air cleanliness according to norm ISO EN 14644-1; • DOS test on HEPA filters(inerti gas like nitrogen at customer charge); UTILITIES BATTERY LIMIT Power lines at Client’s charge. DOCUMENTATION • • • Electric diagram; Maintenance and operator’s manual; Warranty certificate. TD_MVF_08.doc Rev. January 2004 Pag. 3 MVF2 DRAWING 680 1360 40 40 40 500 VISTA FRONTALE 90 112.5 380 VISTA LATERALE 330 DWG N 600 30 1280 57.5 2600.000 40 340 680 89 340 502 89 502 178 502 89 340 340 89 680 40 600 40 1360 480 30 500 1300 30 30 VISTA / SEZIONE FRONTALE 620 680 20 N^ 4 GOLFARI M12 VISTA DALL'ALTO A LETTER 15-4-94 PTIMA EMISSIONE DATE SC DESCRIPTION AB BY CHD APP. REVISIONS APPROVED FOR CONSTRUCTION PASSACAVO A MEMBRANA PER ALIM. ELETTR. MODULO MVF2 DWG. REV. DATE SIGNATURE 30 100 NOT SPECIFIED TOLLERANCE : DIMENSIONI D' INGOMBRO cod.= 00260000000 rif. SP.TEC. TOLL-001 PAINTING: rif. SP.TEC. PAINT-001 THIS DWG.SUPERSEDED BY SCALE THIS DRAWING IS THE PROPERTY OF STERIL AND IS LENT WITHOUT CONSIDERATION OTHER THAN THE BORROWER 'S AGREEMENT THAT IT SHALL NOT BE REPRODUCED 100 TD_MVF_08.doc Rev. January 08 THIS DWG. SUPERSEDES 1:5 COPIED LENT OR DISPOSED OF DIRECTLY OR INDIRECTLY , NOR USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SPECIFICALLY FURNISHED. THE APPARATUS SHOWN IN THE DRAWING IS COVERED BY PATENTS . Pag. 4 DWG.N 2600.000 REV. A MVF3 DRAWING 40 40 905 40 30 905 VISTA FRONTALE 90 112.5 380 VISTA LATERALE 330 DWG N 2849.000 57.5 40 492.5 492.5 492.5 492.5 985 985 925 30 40 905 40 30 30 480 VISTA / SEZIONE FRONTALE 20 925 985 500 n^4 fori M12 A VISTA DALL'ALTO 24-10-97 LETTER PRIMA EMISSIONE DATE SC DESCRIPTION AB BY CHD APP. REVISIONS APPROVED FOR CONSTRUCTION MODULO MVF3 passacavo a membrana per alimentazione elettrica DWG. REV. DATE SIGNATURE TOLLERANZE NON SPECIFICATE: DIMENSIONI D' INGOMBRO 100 rif. SP.TEC. TOLL-001 VERNICIATURA: cod.= 00284900000 rif. SP.TEC. PAINT-001 THIS DWG.SUPERSEDED BY SCALE THIS DRAWING IS THE PROPERTY OF STERIL AND IS LENT WITHOUT CONSIDERATION OTHER THAN THE BORROWER 'S AGREEMENT THAT IT SHALL NOT BE REPRODUCED THIS DWG. SUPERSEDES 1:5 30 COPIED LENT OR DISPOSED OF DIRECTLY OR INDIRECTLY , NOR USED FOR ANY TD_MVF_08.doc Rev. January 2004 100 PURPOSE OTHER THAN THAT FOR WHICH IT IS SPECIFICALLY FURNISHED. THE APPARATUS SHOWN IN THE DRAWING IS COVERED BY PATENTS . Pag. 5 DWG.N 2849.000 REV. A HMVF2 DRAWING 680 680 40 40 40 500 VISTA FRONTALE 90 112.5 380 VISTA LATERALE 330 DWG N 600 30 600 57.5 2760.000 40 89 89 502 502 89 89 680 40 600 40 680 480 30 500 600 30 30 VISTA / SEZIONE FRONTALE 620 680 20 N^ 4 GOLFARI M12 VISTA DALL'ALTO A LETTER 31-01-95 EMESSO DATE SC DESCRIPTION BY CHD APP. REVISIONS APPROVED FOR CONSTRUCTION PASSACAVO A MEMBRANA PER ALIM. ELETTR. MODULO HMVF2 DWG. REV. DATE SIGNATURE 30 100 NOT SPECIFIED TOLLERANCE : DIMENSIONI D' INGOMBRO rif. SP.TEC. TOLL-001 PAINTING: cod.= 00276000000 rif. SP.TEC. PAINT-001 THIS DWG.SUPERSEDED BY SCALE THIS DRAWING IS THE PROPERTY OF STERIL AND IS LENT WITHOUT CONSIDERATION OTHER THAN THE BORROWER 'S AGREEMENT THAT IT SHALL NOT BE REPRODUCED 100 PURPOSE OTHER THAN THAT FOR WHICH IT IS SPECIFICALLY FURNISHED. TD_MVF_08.doc Rev. January 2004 THIS DWG. SUPERSEDES 1:5 COPIED LENT OR DISPOSED OF DIRECTLY OR INDIRECTLY , NOR USED FOR ANY THE APPARATUS SHOWN IN THE DRAWING IS COVERED BY PATENTS . Pag. 6 DWG.N 2760.000 REV. A 1360 1280 40 40 340 330 PANNELLO MAGNEHELIC (MAGNAHELIK PANEL) 40 20 92.5 480 540 100 57.5 B B VISTA FRONTALE (FRONT VIEW) VITE AUTOFIL. TCTCr n4.2x19 (TCTCr SELF-THREADING SCREW) 1360 MAGNEHELIC H1 L0 (libero) (FREE) TUBETTO EXTRAFLEX n4/6 680 (EXTRAFLEX BAROMETRIC PIPE) PORTAGOMMA PK5 (CONNECTOR) PANNELLO MAGNEHELIC (MAGNAHELIK PANEL) SEZIONE "B-B" (SECTION) TD_MVF_08.doc Rev. January 2004 Pag. 7 TD_MVF_08.doc Rev. January 2004 - L.= 680 mm. - COD: 05260000701 2 - L.= 1330 mm. - COD: 05260000702 3 - L.= 1360 mm. - COD: 05260000703 PART. "X" 3 RONDELLA 10 (WASHER) 2 40 2 89 20 89 21.5 1 89 1360 17.5 MVF2 MVF2 (TE SCREW) VITE TE M10x20 DADO IN GABBIA M10 (FASTENING NUT) PART. "X" 3 680 680 1360 PARTICOLARE UNIONE MODULI PART. "X" (MODULES FASTENING DETAIL) Pag. 8