Vault Style Solid Dielectric Switchgear Catalog p G&W headquarters in Bolingbrook, IL USA Company Profile Since 1905, G&W Electric has helped energize the world with innovative power system solutions. With the introduction of the first disconnecting cable terminating device, G&W began to build a reputation for engineering custom solutions to meet the needs of system designers. Solutions which today have extended far beyond cable accessory products and into the latest in load and fault interrupting switchgear, reclosers, system protection equipment and distribution automation. Headquarters G&W headquarters is located in Bolingbrook, IL, USA, a suburb of Chicago. G&W also has manufacturing facilities or sales offices in China, Mexico, Canada, India, Singapore and Brazil. G&W covers the globe with product installations and sales representation in over 100 countries and all seven continents. G&W Electric Facilities: G&W Electric Co. Headquarters (Bolingbrook, IL, USA) G&W China (Shanghai) G&W Canada (Mississauga, Ontario) G&W Mexico (San Luis Potosí) G&W do Brasil (Salvador) G&W sales office (Dubai) G&W sales office (Delhi, India) G&W ELECTRIC G&W Manufacturing Facility G&W sales office (Singapore) G&W Sales Office Manufacturer’s Brass and Aluminum Foundry (Blue Island, IL, USA) PA G E 2 Over 110 Years Serving our Markets G&W Product Overview Single and Three Phase Solid Dielectric Reclosers Solid Dielectric Underground Distribution Switchgear SF6 Underground Distribution Switchgear System Automation and Smart Grid Solutions System Protection Equipment Transmission and Distribution Cable Accessories G&W ELECTRIC PA G E 3 Table of Contents Technology Solid Dielectric Insulation......................................................................................................... 5 Trident with SafeVu................................................................................................................. 5 Multi-way Trident Solid Dielectric Switch Overview................................................................... 6 Multi-way Three Phase Front Access 8 Three Phase Load Break and Three Phase Tripping (VLS-FA).................................................... Three Phase Load Break Ways and Fault Interrupter Ways with Single Phase Tripping (VLT-FA)..........10 Two-way Trident Solid Dielectric Switch Overview....................................................................12 Components for Three Phase Switches.....................................................................................16 Overcurrent Protection Options..................................................................................................17 Single Phase Single Phase Load Break and Fault Interrupting........................................................................18 G&W ELECTRIC PA G E 4 Technology What is solid dielectric insulation? G&W’s solid dielectric insulation is a field proven epoxy which is used to insulate the high voltage connections of a vacuum switch. The load break and fault interrupting vacuum bottle and bushing conductors are fully over molded creating a single phase module. Each module is then coated with a semi-conductive paint creating a continuous grounding surface for a truly dead front design. For three phase switches, three modules are combined together to create one way of the switch. Drive rod Each module can also include an integral current transformer fully protected by the solid dielectric epoxy. This ensures that the transformer is impervious to environmental conditions and insulated from extreme temperatures. Encapsulated current transformer G&W’s molding expertise allows for various options including 200A bushing wells or 600A apparatus bushings. The rugged epoxy surface minimizes the force required for removing elbow connections compared to rubber-to-rubber junctions. Different module orientations are available which permit cable entry from the front, back, or bottom of the unit. Vacuum bottle The solid dielectric insulations and vacuum bottle combination make the Trident switchgear suitable for wet and corrosive environments, vertical or horizontal mounting and use in any altitude. When you need visible break ... Trident with SafeVu™ Trident switches are available with the SafeVu™ option. These switches include an innovative visible break feature built into the switch, which eliminates the need to remove elbows or use externally mounted components to provide a visible open. p Close up of integrated visible The SafeVu operating break in the open position handle is operable via hook stick or rope rigging, making it ideal for subsurface applications where space or safety practices prevent the operator from entering the vault to create a visible break. Description The visible break is achieved with a blade type switch incorporated within the solid dielectric module. The blade is in series with the vacuum interrupter and provides a clear visible open. The blade is easily visible through a viewing window molded as an integral part of each module. p Internal components are shown outside the module as reference. G&W ELECTRIC PA G E 5 Multi-way Trident Solid Dielectric Switches Trident solid dielectric insulated switches provide the total life cycle cost and operational benefits of fuseless, electronically controlled, resettable overcurrent protection, with the safety and maintenance benefits of an environmentally friendly dead-front design. The Trident utilizes G&W’s time proven, submersible epoxy insulation to fully encapsulate load and fault interrupting vacuum interrupters. This solid dielectric insulation eliminates the degradation of dielectric integrity commonly associated with oil and air insulated switchgear. VLS Switch Series The Trident VLS Series is available in two through six way configurations, in any combination of three phase load break switch ways and three phase fault interrupter ways. The fault interrupter utilizes a trip-free mechanism, which provides interruption independent of the operating handle when closing into a fault. Viewing windows provide visible indication of the contact position. VLT Switch Series The Trident VLT Series is available in two through six way configurations, in any combination of three phase load break switch ways and single phase fault interrupter ways. Each fault interrupting mechanism incorporates a tripfree design which permits interruption independent of the operating handle if closing into a fault. Each phase of the fault interrupting mechanism can be independently tripped and reset, providing the ability to maintain energization of the other phases in the case of a single phase fault. Viewing windows permit visible indication of the contact position of all phases. Applications Trident load and fault interrupting combination switches provide a direct replacement for power fused and vacuumin-oil switchgear. Some ideal applications include: Transformer and Motor Protection — The three phase trip feature and high continuous current make the VLS switches ideal for protecting three phase motors and transformer loads. Loop Switching — Standard 600A loop switching is accomplished using field proven vacuum switching and solid dielectric insulation. Switching through 630A provides up to 12.5kA symmetric fault protection using resettable, electronically controlled vacuum interrupters. The vacuum interrupters also function as load break switches. Residential and Fuse Replacement — The single phase trip feature of the VLT switches makes them ideal for protecting single phase motors and transformer loads. G&W ELECTRIC PA G E 6 p Trident VLS Switch Series p Trident VLT Switch Series Additional Features Visible Break — The load break and three phase fault interrupter ways are available with G&W’s SafeVu feature, which provides an integrated visible break disconnect switch in series with the vacuum interrupter. This eliminates the need to remove elbows or use externally mounted linkage systems to provide a visible open. Switches equipped with the SafeVu feature incorporate redundant mechanical interlocks to ensure the load break switch is open prior to the operation of the visible break switch. Testing Trident switches are designed and tested to applicable standards including IEEE C37.74 (IEEE C37.71 and C37.72), IEEE 386, IEC 60265, IEEE 592,. All fault interrupter devices have passed IEEE C37.60. Trident switches are RUS accepted. Fully encapsulated current transformers provide power and sensing for G&W’s Vacuum Interrupter controls. The controls emulate the most common time current curves (TCC) for power fuses, mechanical relays, and fuse links. Control options include Ground Fault (Phase Imbalance), Time Delays, and Inrush Restraint (Cold Load Pickup). Submersibility G&W VLS and VLT solid dielectric switchgear is completely submersible. Units have remained fully operable after withstanding years of submersion at depths of up to 10 feet (3m). Multi-way Trident Solid Dielectric Switches Features and Benefits Features Benefits No maintenance or monitoring system necessary, lowest total life cycle costs Epoxy Insulation (No oil or SF6 gas, and dead-front design) Dead-front design provides increased operator safety by eliminating all exposed live parts Epoxy is inert, environmentally friendly, with no EPA usage restrictions Resettable Vacuum Interrupter Mechanism No fuses or fuse links to stock and replace Integral self-powered overcurrent protection available Integrated solution with fully encapsulated current transformers and no external power source or PT required Ratings The switch is designed, tested and built per IEEE C37.74 for load break switching, IEEE C37.60 for fault interrupting, IEEE 386 for bushing specification, and IEC 60529 for environmental protection rating. Certified test reports are available. Load Break Ratings Fault Interrupting Ratings Voltage Class 15kV *, † 25kV † Voltage Class 15kV *, † 25kV † Max System Voltage 15.5kV 27kV Max System Voltage 15.5kV 27kV BIL Impulse 110kV ‡ 125kV BIL Impulse 110kV ‡ 125kV Continuous Current 630A 630A Continuous Current 630A 630A Load Break Current 630A 630A AC Withstand, 1 minute 35kV 60kV AC Withstand, 1 minute 35kV 60kV AC Withstand, Production, 1 minute 34kV 40kV 34kV 40kV AC Withstand, Production, 1 minute DC Withstand, 15 minutes 53kV 78kV 53kV 78kV Momentary Current, RMS, asym 20kA 20kA 12.5kA 12.5kA Fault-Close 3-times, asym 20kA 20kA 2,000 2,000 1 Second Current, sym 12.5kA 12.5kA Load Break Switch Mechanical Operations 2,000 2,000 (*) SafeVu available on 15kV load break and three phase fault interrupters. (VLS-FA configurations.) (†) 15kV and 25kV class available for single phase fault interrupters (VLT-FA configurations) (‡) BIL impulse rating is 95kV when using SafeVu feature. DC Withstand, 15 minutes Fault Interrupting Current, sym Vacuum Interrupter Mechanical Operations IEEE C37.60 Fault Interrupting Duty Percent of Maximum Interrupting Rating Approximate Interrupting Current, Amps Number of Fault Interruptions 15-20% 2,000 44 45-55% 6,000 56 90-100% 12,500 16 Total Number of Fault Interruptions: 116 G&W ELECTRIC PA G E 7 Front Access VLS-FA Switch Series Model One-line Diagram Voltage (kv) WIDTH 15 6 Width Inches (mm) Weight lbs (kg) VLS32-376-12-6FA 78 (1990) 1400 (700) VLS32-376-12-6FAVU* 90 (2290) 1600 (800) VLS32-386-12-6FA 78 (1990) 1400 (700) VLS31-376-12-7FA 78 (1990) 1400 (700) VLS31-376-12-7FAVU* 90 (2290) 1600 (800) VLS31-386-12-7FA 78 (1990) 1400 (700) VLS42-376-12-9FA 103 (2620) 1500 (700) VLS42-376-12-9FAVU* 120 (3050) 1900 (900) VLS42-386-12-9FA 103 (2620) 1500 (700) VL44-376-20-10FA 103 (2620) 1500 (700) VL44-376-20-10FAVU* 120 (3050) 1900 (900) VL44-386-20-10FA 103 (2620) 1500 (700) VLS43-376-12-11FA 103 (2620) 1500 (700) VLS43-376-12-11FAVU* 120 (3050) 1900 (900) VLS43-386-12-11FA 103 (2620) 1500 (700) VLS41-376-12-12FA 103 (2620) 1500 (700) VLS41-376-12-12FAVU* 120 (3050) 1900 (900) VLS41-386-12-12FA 103 (2620) 1500 (700) VL33-376-20-13FA 78 (1990) 1400 (700) VL33-376-20-13FAVU* 90 (2290) 1600 (800) VL33-386-20-13FA 78 (1990) 1400 (700) VS40-376-12-40FA 103 (2620) 1500 (700) VS40-376-12-40FAVU* 120 (3050) 1900 (900) VS40-386-12-40FA 103 (2620) 1500 (700) VS50-376-12-50FA 128 (3260) 1800 (900) VS50-376-12-50FAVU* 150 (3810) 2100 (1000) VS50-386-12-50FA 128 (3260) 1800 (900) VLS51-376-12-51FA 128 (3260) 1800 (900) VLS51-376-12-51FAVU* 150 (3810) 2100 (1000) VLS51-386-12-51FA 128 (3260) 1800 (900) VLS52-376-12-52FA 128 (3260) 1800 (900) VLS52-376-12-52FAVU* 150 (3810) 2100 (1000) VLS52-386-12-52FA 128 (3260) 1800 (900) 25 HEIGHT 53” (1347mm) 15 7 25 FRONT This drawing and the information the ENCLOSURE .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" OVAL SUPPLIED BY G&W 2.19 [56] 3D MODEL MC ERRORS 0 DRAWING MC ERRORS 0 3D MODEL LAST CHECKED Wed Nov 09 2011 18:25:06 GMT-0600 3_PHASE_TRID_S_SIDE_HANDLE_CUST DRAWING LAST CHECKED Wed Nov 09 2011 20:14:59 GMT-0600 STANDARD SHEET 1 of 2 0.86 76] BOTTOM VIEW SHOWING ELECTRONIC CABLE OUTPUT SEE NOTES FOR LIMITATIONS MAXIMUM DESIGN VOLTAGE IMPULSE LEVEL 1 BIL AC 1 MIN. WITHSTAND DC 15 MIN. WITHSTAND CURRENT CONTINUOUS CURRENT INTERRUPTING MOMENTARY CURRENT RMS ASYM. MAKING CURRENT RMS ASYM. 1 SEC. RATING RMS SYM. 15.5 110 34 53 630 630 20 20 12.5 ALL WAYS KV KV KV KV AMP AMP KA KA KA ELECTRONIC CABLE OUTPUT WAYS 3 & 4 (CABLE CUT TO LENGTH) ENCLOSURE MOUNTING DETAIL "A" NOTES: 9 10.86 [276] 84.0 [2135] ADJUSTABLE ENCLOSURE MOUNTING 2.19 56MM TYP. 44.00 [1118] 92.13 [2340] 37.8 [960] ADJUSTABLE ENCLOSURE MOUNTING 2200 LBS/ 1000 KG 4.00 [102] CABLE TRAINING OUTLINE 3. SWITCH ELECTRICAL RATINGS MAY BE REDUCED BY THE CHOICE OF ENTRANCES. 10 101.59 [2580] ENCLOSURE MOUNTING 50.38 [1280] 4. GALVANIZED STEEL ENCLOSURE FINISHED MUNSELL 7GY3.29/1.5 PADMOUNT GREEN. SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN 8. SWITCH IS EQUIPPED WITH 2 FORM C AUXILIARY CONTACTS ON ALL WAYS. BOTH FORM C CONTACTS FROM ALL 4 WAYS ARE TERMINATED INTO THE NEMA 4X JUNCTION BOX FOR CUSTOMER USE. SIDE ITEM NO. FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED 3.00 [76] ELECTRONICS WAY2: WAY1: 2.19 [56] TYP. WAY3: 15 TYPE 2 15-300A TYPE 2 15-300A WAY4: * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. 25 ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. PA13-SL1SL1S21S21 FOUR WAY SOLID DIELECTRIC SWITCH G&W ELECTRIC Co. CAT. NO.: DRAWN BY: PA13-SL1SL1S21S21 N.A. REV DRAWING NO. DATE: DATE: Nov-09-11 D97LL FF00 L00 SCALE: 15 SHEET: 1 of 2 ENTRANCES 1 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 2 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** 3 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** 4 12 ** ELBOWS AND INSERTS PROVIDED BY OTHERS AND MAY HAVE REDUCED ELECTRICAL RATINGS. 15 PRINT IDENTIFICATION G&W NO. 25 CUSTOMER ORDER NO. Depth= 32in (813 mm) 34in (864mm) with SafeVu feature ITEM NO. FOR RECORD FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED 3.00 [76] ELECTRONICS 2.19 [56] TYP. WAY3: 13 WAY2: WAY1: TYPE 2 15-300A Height = 53 in (1347 mm) with standard 24” Bushing height. WAY4: TYPE 2 15-300A 15 25 * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. ALL DOORS EQUIPPED WITH PENTA HEAD BOLT AND THREE POINT LATCHING ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. PA13-SL1SL1S21S21 FOUR WAY SOLID DIELECTRIC SWITCH PLAN VIEW SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN 25 G&W NO. ORDER NO. APPR BY: DATE 22.00 [559] 101.59 [2580] ENCLOSURE MOUNTING PRINT IDENTIFICATION CUSTOMER 25 SEE ENCLOSURE MOUNTING DETAIL "A" 8.27 [210] 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** DATE PLAN VIEW 7. 200 AMP RATED DEEPWELL BUSHINGS WILL REDUCE THE ELECTRICAL RATINGS TO 200 AMP CONTINUOUS AND 15 KA ASYM. FOR 10 CYCLES. WAY CABLE TRAINING OUTLINE 8.27 [210] ALL DOORS EQUIPPED WITH PENTA HEAD BOLT AND THREE POINT LATCHING DEPTH 92.13 [2340] 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** FOR RECORD 94.38 [2397] 2. UNFINISHED 304 STAINLESS STEEL MOUNTING PLATE WITH BOLTED STAINLESS MECHANISM COVER FINISHED ASA 70 LIGHT GRAY. 11 84.0 [2135] ADJUSTABLE ENCLOSURE MOUNTING 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** ** ELBOWS AND INSERTS PROVIDED BY OTHERS AND MAY HAVE REDUCED ELECTRICAL RATINGS. 1. ALL SWITCHED WAYS EQUIPPED WITH INTERNAL SPRING OPERATOR AND EXTERNAL PROVISIONS FOR PADLOCKING IN ALL POSITIONS 6. SWITCH IS EQUIPPED WITH NEMA 4X TYPE 2, 15-300 AMP ELECTRONIC CONTROLS ON WAYS 3 & 4. SWITCH WEIGHT 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 2 4 SEE ENCLOSURE MOUNTING DETAIL "A" 22.00 [559] 5. ENCLOSURE IS DESIGNED PER APPLICABLE SECTIONS OF ANSI/IEEE C37.72 AND ANSI C57.12.28. DRAWING IS TYPICAL AND SHOWS OVERALL DIMENSIONS ONLY. CONSTRUCTION DETAILS MAY VARY FROM THOSE DEPICTED. THREE LINE DIAGRAM ENTRANCES 1 3 1.50 38MM MIN. CONCRETE PAD SWITCH ELECTRICAL INFORMATION 15 WAY .625" DIA. HARDWARE (4)-SUPPLIED BY USER Approximate Catalog Number G&W ELECTRIC Co. CAT. NO.: DRAWN BY: PA13-SL1SL1S21S21 N.A. APPR BY: REV DRAWING NO. DATE: Nov-09-11 DATE: D97LL FF00 L00 SCALE: Dimensions are approximate. Do not use for construction. SHEET: 1 of 2 40 15 25 50 15 25 51 15 25 Visit gwelec.com/specs.html for electronic versions of guide specifications. G&W ELECTRIC PA G E 8 52 15 25 *VU indicates the switch includes the SafeVu integrated visible break. Front Access VLS-FA Switch Series Model One-line Diagram Voltage (kv) Width Inches (mm) Weight lbs (kg) VLS53-376-12-53FA 128 (3260) 1800 (900) VLS53-376-12-53FAVU* 150 (3810) 2100 (1000) VLS53-386-12-53FA 128 (3260) 1800 (900 VLS54-376-12-54FA 128 (3260) 1800 (900) VLS54-376-12-54FAVU* 150 (3810) 2100 (1000) VLS54-386-12-54FA 128 (3260) 1800 (900) VL55-376-20-55FA 128 (3260) 1800 (900) VL55-376-20-55FAVU* 150 (3810) 2100 (1000) VL55-386-20-55FA 128 (3260) 1800 (900) VS60-376-12-60FA 153 (3900) 2000 (1000) VS60-376-12-60FAVU* 180 (4580) 2400 (1100) VS60-386-12-60FA 153 (3900) 2000 (1000) VLS61-376-12-61FA 153 (3900) 2000 (1000) VLS61-376-12-61FAVU* 180 (4580) 2400 (1100) VLS61-386-12-61FA 153 (3900) 2000 (1000) VLS62-376-12-62FA 153 (3900) 2000 (1000) VLS62-376-12-62FAVU* 180 (4580) 2400 (1100) VLS62-386-12-62FA 153 (3900) 2000 (1000) VLS63-376-12-63FA 153 (3900) 2000 (1000) VLS63-376-12-63FAVU* 180 (4580) 2400 (1100) VLS63-386-12-63FA 153 (3900) 2000 (1000) VLS64-376-12-64FA 153 (3900) 2000 (1000 VLS64-376-12-64FAVU* 180 (4580) 2400 (1100) VLS64-386-12-64FA 153 (3900) 2000 (1000) VLS65-376-12-65FA 153 (3900) 2000 (1000) VLS65-376-12-65FAVU* 180 (4580) 2400 (1100) VLS65-386-12-65FA 153 (3900) 2000 (1000) VL66-376-20-66FA 153 (3900) 2000 (1000) VL66-376-20-66FAVU* 180 (4580) 2400 (1100) VL66-386-20-66FA 153 (3900) 2000 (1000) WIDTH 15 53 25 HEIGHT 53” (1347mm) 15 54 25 FRONT This drawing and the information the ENCLOSURE .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" OVAL SUPPLIED BY G&W 2.19 [56] 3D MODEL MC ERRORS 0 DRAWING MC ERRORS 0 3D MODEL LAST CHECKED Wed Nov 09 2011 18:25:06 GMT-0600 3_PHASE_TRID_S_SIDE_HANDLE_CUST DRAWING LAST CHECKED Wed Nov 09 2011 20:14:59 GMT-0600 STANDARD SHEET 1 of 2 BOTTOM VIEW SHOWING ELECTRONIC CABLE OUTPUT SEE NOTES FOR LIMITATIONS MAXIMUM DESIGN VOLTAGE IMPULSE LEVEL 1 BIL AC 1 MIN. WITHSTAND DC 15 MIN. WITHSTAND CURRENT CONTINUOUS CURRENT INTERRUPTING MOMENTARY CURRENT RMS ASYM. MAKING CURRENT RMS ASYM. 1 SEC. RATING RMS SYM. 15.5 110 34 53 630 630 20 20 12.5 ALL WAYS KV KV KV KV AMP AMP KA KA KA ELECTRONIC CABLE OUTPUT WAYS 3 & 4 (CABLE CUT TO LENGTH) ENCLOSURE MOUNTING DETAIL "A" NOTES: 55 10.86 [276] 84.0 [2135] ADJUSTABLE ENCLOSURE MOUNTING 2.19 56MM TYP. 44.00 [1118] 92.13 [2340] 37.8 [960] ADJUSTABLE ENCLOSURE MOUNTING 2200 LBS/ 1000 KG 4.00 [102] CABLE TRAINING OUTLINE 60 3. SWITCH ELECTRICAL RATINGS MAY BE REDUCED BY THE CHOICE OF ENTRANCES. 101.59 [2580] ENCLOSURE MOUNTING 50.38 [1280] 4. GALVANIZED STEEL ENCLOSURE FINISHED MUNSELL 7GY3.29/1.5 PADMOUNT GREEN. 37.8 [960] DJUSTABLE NCLOSURE MOUNTING 92.13 [2340] 8. SWITCH IS EQUIPPED WITH 2 FORM C AUXILIARY CONTACTS ON ALL WAYS. BOTH FORM C CONTACTS FROM ALL 4 WAYS ARE TERMINATED INTO THE NEMA 4X JUNCTION BOX FOR CUSTOMER USE. SIDE 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 2 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 3 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** 4 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** 62 ** ELBOWS AND INSERTS PROVIDED BY OTHERS AND MAY HAVE REDUCED ELECTRICAL RATINGS. G&W NO. WAY3: ITEM NO. WAY2: WAY1: 2.19 [56] TYP. 15 TYPE 2 15-300A TYPE 2 15-300A WAY4: * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. 25 ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. PA13-SL1SL1S21S21 FOUR WAY SOLID DIELECTRIC SWITCH G&W ELECTRIC Co. CAT. NO.: DRAWN BY: PA13-SL1SL1S21S21 N.A. REV DRAWING NO. DATE: DATE: Nov-09-11 D97LL FF00 L00 15 SCALE: 15 25 CUSTOMER SHEET: 1 of 2 ORDER NO. ITEM NO. FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED 3.00 [76] ELECTRONICS 2.19 [56] TYP. WAY3: 63 WAY2: WAY1: TYPE 2 15-300A WAY4: Height = 53 in (1347 mm) with standard 24” Bushing height. TYPE 2 15-300A 15 25 * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. ALL DOORS EQUIPPED WITH PENTA HEAD BOLT AND THREE POINT LATCHING ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. PA13-SL1SL1S21S21 FOUR WAY SOLID DIELECTRIC SWITCH PLAN VIEW SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN ELECTRONICS PRINT IDENTIFICATION Depth= 32in (813 mm) 34in (864mm) with SafeVu feature 101.59 [2580] ENCLOSURE MOUNTING FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED 3.00 [76] ENTRANCES 1 DATE 22.00 [559] CABLE TRAINING OUTLINE ORDER NO. 25 SEE ENCLOSURE MOUNTING DETAIL "A" 8.27 [210] 25 G&W NO. CUSTOMER APPR BY: FOR RECORD 4.00 [102] PRINT IDENTIFICATION DATE PLAN VIEW SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN WAY 84.0 [2135] ADJUSTABLE ENCLOSURE MOUNTING 8.27 [210] ALL DOORS EQUIPPED WITH PENTA HEAD BOLT AND THREE POINT LATCHING 7. 200 AMP RATED DEEPWELL BUSHINGS WILL REDUCE THE ELECTRICAL RATINGS TO 200 AMP CONTINUOUS AND 15 KA ASYM. FOR 10 CYCLES. DEPTH 10.86 [276] 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** 15.5KV 200AMP 110KV BIL DEEPWELL BUSHING ** ** ELBOWS AND INSERTS PROVIDED BY OTHERS AND MAY HAVE REDUCED ELECTRICAL RATINGS. FOR RECORD 94.38 [2397] 2. UNFINISHED 304 STAINLESS STEEL MOUNTING PLATE WITH BOLTED STAINLESS MECHANISM COVER FINISHED ASA 70 LIGHT GRAY. 61 2.19 [56] 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 4 1. ALL SWITCHED WAYS EQUIPPED WITH INTERNAL SPRING OPERATOR AND EXTERNAL PROVISIONS FOR PADLOCKING IN ALL POSITIONS 6. SWITCH IS EQUIPPED WITH NEMA 4X TYPE 2, 15-300 AMP ELECTRONIC CONTROLS ON WAYS 3 & 4. SWITCH WEIGHT 15.5KV 630AMP 110KV BIL APPARATUS BUSHING ** 2 3 SEE ENCLOSURE MOUNTING DETAIL "A" 22.00 [559] 5. ENCLOSURE IS DESIGNED PER APPLICABLE SECTIONS OF ANSI/IEEE C37.72 AND ANSI C57.12.28. DRAWING IS TYPICAL AND SHOWS OVERALL DIMENSIONS ONLY. CONSTRUCTION DETAILS MAY VARY FROM THOSE DEPICTED. THREE LINE DIAGRAM ENTRANCES 1 1.50 38MM MIN. CONCRETE PAD SWITCH ELECTRICAL INFORMATION 15 WAY .625" DIA. HARDWARE (4)-SUPPLIED BY USER Approximate Catalog Number G&W ELECTRIC Co. CAT. NO.: DRAWN BY: APPR BY: PA13-SL1SL1S21S21 N.A. REV DRAWING NO. DATE: Nov-09-11 DATE: Dimensions are approximate. Do not use for construction. D97LL FF00 L00 SCALE: SHEET: 1 of 2 64 15 25 65 15 25 66 15 25 *VU indicates the switch includes the SafeVu integrated visible break. Visit gwelec.com/specs.html for electronic versions of guide specifications. G&W ELECTRIC PA G E 9 Front Access VLT-FA Switch Series Model One-line Diagram Voltage (kv) WIDTH 15 6 25 HEIGHT 56” (1423mm) 15 7 25 15 9 FRONT DRAWING REVIEW TEAM 25 REVISIONS DATE 15 11 BOTTOM VIEW (WAY 1) 25 SHOWING CABLE FEEDTHRU SWITCH ELECTRICAL INFORMATION Approximate Catalog Number Width Inches (mm) VLT32-376-12-6FA 78 (1990) 1400 (700) VLT32-376-12-6FAVU* 90 (2290) 1600 (800) VLT32-386-12-6FA 78 (1990) 1400 (700) VLT31-376-12-7FA 78 (1990) 1600 (800) VLT31-376-12-7FAVU* 90 (2290) 1600 (800) VLT31-386-12-7FA 78 (1990) 1600 (800) VLT42-376-12-9FA 103 (2620) 1700 (800) VLT42-376-12-9FAVU* 120 (3050) 1900 (900) VLT42-386-12-9FA 103 (2620) 1700 (800) VLT43-376-12-11FA 103 (2620) 1600 (800) VLT43-376-12-11FAVU* 120 (3050) 1900 (900) VLT43-386-12-11FA 103 (2620) 1600 (800) SEE NOTES FOR LIMITATIONS WAY 1 MAXIMUM DESIGN VOLTAGE IMPULSE LEVEL 1 BIL AC 1 MIN. WITHSTAND DC 15 MIN. WITHSTAND CURRENT CONTINUOUS CURRENT INTERRUPTING MOMENTARY CURRENT RMS ASYM. MAKING CURRENT RMS ASYM. 1 SEC. RATING RMS SYM. 15.5 110 34 53 630 630 20 25.6 12.5 KV KV KV KV AMP AMP KA KA KA WAYS 2 & 3 15.5 KV 110 KV 34 KV 53 KV 630 AMP 16 KA BOTTOM VIEW (WAYS 2 & 3) .625" DIA. HARDWARE (4)-SUPPLIED BY USER 15 12 ENCLOSURE PLAN VIEW .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" SLOTTED HOLE SUPPLIED BY G&W 25 SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN VLT41-376-12-12FA 103 (2620) VLT41-376-12-12FAVU* ORDER NO. 120 (3050) FOR RECORD FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED VLT41-386-12-12FA 103 (2620) VT40-376-12-40FA 103 (2620) ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. SWITCH WEIGHT 2200 LBS/ 998 KG DEPTH ENCLOSURE MOUNTING DETAIL "A" WAY 2.19 56MM TYP. 40 15 ENTRANCES 1 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 2 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 3 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 PA13-SL1T11T11 VT40-376-12-40FAVU* CAT. NO.: 25 50 Depth= 32in (813 mm) 34in (864mm) with SafeVu feature 25 PRINT IDENTIFICATION Height = 53 in (1347 mm) with standard 24” Bushing height. DATE G&W NO. 51 CUSTOMER ORDER NO. FOR RECORD EW 15 25 * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. Dimensions are approximate. Do not use for construction. PA13-SL1T11T11 ENTRANCES THREE WAY SOLID DIELECTRIC SWITCH PAD 0649A 0KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 0KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 CAT. NO.: 10KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 DRAWN BY: PA13-SL1T11T11 NMD APPR BY: DATE: 9-26-14 DATE: G&W ELECTRIC Co. REV DRAWING NO. D97LF F000 R00 SCALE: SHEET: 52 1 of 2 15 25 53 15 25 1900 (900) 1800 (900) 1900 (900) DRAWN BY: PA13-SL1T11T11 NMD 120 (3050) 1900 (900) D97LF F000 R00 G&W ELECTRIC Co. DRAWING NO. DATE: DATE: REV 9-26-14 SCALE: SHEET: 1 of 2 VT40-386-12-40FA 103 (2620) 1900 (900) VT50-376-12-50FA 128 (3260) 2200 (1000) VT50-376-12-50FAVU* 150 (3810) 2300 (1100) VT50-386-12-50FA 128 (3260) 2200 (1000) VLT51-376-12-51FA 128 (3260) 2100 (1000) VLT51-376-12-51FAVU* 150 (3810) 2200 (1000) VLT51-386-12-51FA 128 (3260) 2100 (1000) VLT52-376-12-52FA 128 (3260) 2000 (1000) VLT52-376-12-52FAVU* 150 (3810) 2200 (1000) VLT52-386-12-52FA 128 (3260) 2000 (1000) VLT53-376-12-53FA 128 (3260) 1900 (900) VLT53-376-12-53FAVU* 150 (3810) 2100 (1000) VLT53-386-12-53FA 128 (3260) 1900 (900) *VU indicates the switch includes the SafeVu integrated visible break. Visit gwelec.com/specs.html for electronic versions of guide specifications. G&W ELECTRIC ITEM NO. ITEM NO. FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED NS AND MAXIMUM OORS ARE OPEN 15 1800 (900) THREE WAY SOLID DIELECTRIC SWITCH PAD 0649A APPR BY: SIDE DATE G&W NO. CUSTOMER * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. 1.50 38MM MIN. CONCRETE PAD REVISIONS PRINT IDENTIFICATION DATE SHOWING CABLE FEEDTHRU Weight lbs (kg) DRAWING REVIEW TEAM PA G E 1 0 Front Access D97LF F000 R00 VLT-FA Switch Series Model One-line Diagram Voltage (kv) VLT54-376-12-54FA 128 (3260) 1900 (900) VLT54-376-12-54FAVU* 150 (3810) 2100 (1000) VLT54-386-12-54FA 128 (3260) 2200 (1000) VT60-376-12-60FA 153 (3900) 2500 (1200) VT60-376-12-60FAVU* 180 (4580) 2600 (1200) VT60-386-12-60FA 153 (3900) 2500 (1200) VLT61-376-12-61FA 153 (3900) 2400 (1100) VLT61-376-12-61FAVU* 180 (4580) 2600 (1200) VLT61-386-12-61FA 153 (3900) 2400 (1100) VLT62-376-12-62FA 153 (3900) 2300 (1000) VLT62-376-12-62FAVU* 180 (4580) 2600 (1200) VLT62-386-12-62FA 153 (3900) 2300 (1000) DWG. NO.: 15 &W. expressed written consent of G 25 d or diclosed to others without the HEIGHT 56” (1423mm) 15 60 property of G &W and are not to be copied, reproduce 25 reon are and remain the FRONT 15 61 DRAWING REVIEW TEAM Weight lbs (kg) DRAWING REVIEW TEAM REVISIONS DATE REVISIONS DATE This drawing and the information the 25 62 BOTTOM VIEW (WAY 1) SHEET 1 of 2 15 SHOWING CABLE FEEDTHRU 25 SWITCH ELECTRICAL INFORMATION SEE NOTES FOR LIMITATIONS MAXIMUM DESIGN VOLTAGE IMPULSE LEVEL 1 BIL AC 1 MIN. WITHSTAND DC 15 MIN. WITHSTAND CURRENT CONTINUOUS CURRENT INTERRUPTING MOMENTARY CURRENT RMS ASYM. MAKING CURRENT RMS ASYM. 1 SEC. RATING RMS SYM. 3D MODEL MC ERRORS 0 DRAWING MC ERRORS 0 WAY 1 15.5 KV 110 KV 34 KV 53 KV 630 AMP 630 AMP 20 KA 25.6 KA 12.5 KA WAYS 2 & 3 15.5 KV 110 KV 34 KV 53 KV 630 AMP 16 KA BOTTOM VIEW (WAYS 2 & 3) SHOWING CABLE FEEDTHRU .625" DIA. HARDWARE (4)-SUPPLIED BY USER 63 ENCLOSURE .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" SLOTTED HOLE SUPPLIED BY G&W CONCRETE PAD PRINT IDENTIFICATION DATE 15 PLAN VIEW SHOWING OVERALL DIMENSIONS AND MAXIMUM DIMENSIONS WHEN ENCLOSURE DOORS ARE OPEN 25 1.50 38MM MIN. 3D MODEL LAST CHECKED Fri Sep 26 2014 15:43:14 GMT-0600 STANDARD DRAWING LAST CHECKED Fri Sep 26 2014 15:44:31 GMT-0600 STANDARD Width Inches (mm) WIDTH 54 Approximate Catalog Number VLT63-376-12-63FA G&W NO. CUSTOMER ORDER NO. VLT63-376-12-63FAVU* VLT63-386-12-63FA 153 (3900) FOR RECORD 180 (4580) 2100 (1000) ITEM NO. FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED 153 (3900) * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. 2600 (1200) 2100 (1000) PA13-SL1T11T11 SWITCH WEIGHT 2200 LBS/ 998 KG DEPTH ENCLOSURE MOUNTING DETAIL "A" WAY 2.19 56MM TYP. SIDE 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 2 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 15 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 25 Depth= 32in (813 mm) 34in (864mm) with SafeVu feature 65 DATE G&W NO. CAT. NO.: DRAWN BY: THREE WAY SOLID DIELECTRIC SWITCH PAD 0649A PA13-SL1T11T11 NMD VLT64-376-12-64FAVU* 153 (3900) DRAWING NO. DATE: 9-26-14 2000 (1000) G&W ELECTRIC Co. REV D97LF F000 R00 180 (4580) 2600 (1200) VLT64-386-12-64FA 153 (3900) 2000 (1000) VLT65-376-12-65FA 153 (3900) 1900 (900) VLT65-376-12-65FAVU* 180 (4580) 2600 (1200) VLT65-386-12-65FA 153 (3900) 1900 (900) APPR BY: DATE: SCALE: SHEET: 1 of 2 *VU indicates the switch includes the SafeVu integrated visible break. CUSTOMER ORDER NO. FOR RECORD PLAN VIEW 15 25 PRINT IDENTIFICATION Height = 53 in (1347 mm) with standard 24” Bushing height. VLT64-376-12-64FA 1 3 64 ENTRANCES ITEM NO. FOR APPROVAL-NO MORE WORK TO BE DONE UNTIL APPROVAL IS RECEIVED RALL DIMENSIONS AND MAXIMUM EN ENCLOSURE DOORS ARE OPEN * ALL PRIMARY DIMENSIONS ARE IN INCHES. ALL SECONDARY DIMENSIONS ARE IN MILLIMETERS. ALL DRAWING CHANGES MUST BE MADE ON CAD. ANY MANUAL CHANGES WILL VOID DRAWING. Dimensions are approximate. Do not use for construction. PA13-SL1T11T11 WAY ENTRANCES 1 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 2 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 3 15.5KV 110KV BIL 200A BUSHING WELL PER IEEE 386 FIGURE 3 THREE WAY SOLID DIELECTRIC SWITCH PAD 0649A CAT. NO.: DRAWN BY: APPR BY: PA13-SL1T11T11 NMD DATE: 9-26-14 DATE: G&W ELECTRIC Co. REV DRAWING NO. D97LF F000 R00 SCALE: SHEET: 1 of 2 Visit gwelec.com/specs.html for electronic versions of guide specifications. G&W ELECTRIC PA G E 1 1 Two-way Trident Solid Dielectric Switches Trident solid dielectric insulated switches provide the total life cycle cost and operational benefits of fuseless, electronically controlled, resettable overcurrent protection, with the safety and maintenance benefits of an environmentally friendly dead-front design. The Trident utilizes G&W’s time proven, submersible epoxy insulation to fully encapsulate load and fault interrupting vacuum interrupters. This solid dielectric insulation eliminates the degradation of dielectric integrity commonly associated with oil and air insulated switchgear. Configurations The two way Trident is available as a loadbreak switch or a fault interrupter. The fault interrupter utilizes a trip-free mechanism, which provides interruption independent of the operating handle when closing into a fault. Viewing windows provide visible indication of the contact position. Applications Trident load and fault interrupting switches provide a direct replacement for vacuum-in-oil switchgear. Some ideal applications include: Transformer and Motor Protection — The three phase trip feature and high continuous current make the two way Trident fault interrupters switches ideal for protecting three phase motors and transformer loads. Oil Fuse Cutout Replacement — Eliminate the need to replace fuse links or maintain insulating oil. The Trident with SafeVu does not require any maintenance and features compact size, lightweight, integral visible break, and fault interrupting capability. It is the perfect solution to replace obsolete oil fuse cutouts. Additional Features Visible Break — The Front Access two way Trident is available with G&W’s SafeVu feature, which provides an integrated visible break disconnect switch in series with the vacuum interrupter. This eliminates the need to remove elbows or use externally mounted linkage systems to provide a visible open. Switches equipped with the SafeVu G&W ELECTRIC PA G E 1 2 p Front Access Design feature incorporate redundant mechanical interlocks to ensure the load break switch is open prior to the operation of the visible break switch. Testing Trident switches are designed and tested to applicable standards including IEEE C37.74 (IEEE C37.71 and C37.72), IEEE 386, IEC 60265, and IEEE 592, All fault interrupter devices have passed IEEE C37.60. Trident switches are RUS accepted. Fully encapsulated current transformers provide power and sensing for G&W’s Vacuum Interrupter controls. The controls emulate the most common time current curves (TCC) for power fuses, mechanical relays, and fuse links. Control options include Ground Fault (Phase Imbalance), Time Delays, and Inrush Restraint (Cold Load Pickup). Submersibility G&W solid dielectric switchgear is completely submersible. Units have remained fully operable after withstanding years of submersion at depths of up to 10 feet (3m). Two-way Trident Solid Dielectric Switches Features and Benefits Features Benefits No maintenance or monitoring system necessary, lowest total life cycle costs Epoxy Insulation (No oil or SF6 gas, and dead-front design) Dead-front design provides increased operator safety by eliminating all exposed live parts Epoxy is inert, environmentally friendly, with no EPA usage restrictions Resettable Vacuum Interrupter Mechanism No fuses or fuse links to stock and replace Integral self-powered overcurrent protection available Integrated solution with fully encapsulated current transformers and no external power source or PT required Ratings The switch is designed, tested and built per IEEE C37.74 for load break switching, IEEE C37.60 for fault interrupting, IEEE 386 for bushing specification, and IEC 60529 for environmental protection rating. Certified test reports are available. Load Break Ratings Fault Interrupting Ratings Voltage Class 15kV * 25kV 35kV Voltage Class 15kV * 25kV 35kV Max System Voltage 15.5kV 27kV 38kV Max System Voltage 15.5kV 27kV 38kV BIL Impulse 110kV † 125kV 150kV BIL Impulse 110kV † 125kV 150kV Continuous Current 630A 630A 630A Continuous Current 630A 630A 630A Load Break Current 630A 630A 630A AC Withstand, 1 minute 35kV 60kV 70kV AC Withstand, 1 minute 35kV 60kV 70kV AC Withstand, Production, 1 minute 34kV 40kV 50kV 34kV 40kV 50kV AC Withstand, Production, 1 minute 53kV 78kV 103kV 53kV 78kV 103kV 12.5kA 12.5kA 12.5kA 20kA 20kA 20kA Fault-Close 3-times, asym 2,000 2,000 2,000 20kA 20kA 20kA 1 Second Current, sym 12.5kA 12.5kA 12.5kA Load Break Switch Mechanical Operations 2,000 2,000 2,000 DC Withstand, 15 minutes Momentary Current, RMS, asym (*) SafeVu available on 15kV load break and three phase fault interrupters. (†) BIL impulse rating is 95kV when using SafeVu feature. DC Withstand, 15 minutes Fault Interrupting Current, sym Vacuum Interrupter Mechanical Operations IEEE C37.60 Fault Interrupting Duty Percent of Maximum Interrupting Rating Approximate Interrupting Current, Amps Number of Fault Interruptions 15-20% 2,000 44 45-55% 6,000 56 90-100% 12,500 16 Total Number of Fault Interruptions: 116 G&W ELECTRIC PA G E 1 3 Two-way Trident Solid Dielectric Switches Front Access Switch Series DRAWING REVIEW TEAM A DEPTH 15” (382mm) WIDTH 24” (610mm) Model One-line Diagram CHANGE 204309 CL REV. A Catalog Number 15 [787] VL21-376-20-3FA 25 VL21-386-20-3FA 35 VL21-396-20-3FA 3 15 25.00 [635] 4 25 35 ADJUSTABLE ENCLOSURE MOUNTING UP TO 21.75 [552] VS20-386-12-4FA VS20-396-12-4FA 3.00 [76] 53.75 [1365] 26.63 [676] ENCLOSURE MOUNTING 26.00 [660] 26.00 [660] SIDE PLAN VIEW SHOWING MAXIMUM DIMENSIONS WHEN ENCLOSURE DOOR IS OPEN PLAN VIEW SHOWING MAXIMUM DIMENSIONS WHEN ENCLOSURE DOOR IS OPEN .625" DIA. HARDWARE (4)-SUPPLIED BY USER SWITCH ELECTRICAL INFORMATION SEE NOTES FOR LIMITATIONS 15.5 110 34 53 630 12.5 KV KV KV KV AMP KA G&W ELECTRIC PA G E 1 4 ENCLOSURE .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" SLOTTED HOLE SUPPLIED BY G&W ENCLOSURE MOUNTING DETAIL "A" 1.50 38MM MIN. 2.19 56MM TYP. WAY 1 2 PRINT IDENTIFICATION CONCRETE PAD ENCLOSURE MOUNTING DETAIL "A" ENTRANCES 1.50 38MM MIN. .25" STAINLESS STEEL ANCHOR BRACKET WITH .875" X 1.125" SLOTTED HOLE SUPPLIED BY G&W CONCRETE PAD MUM DESIGN VOLTAGE LSE LEVEL ( BIL ) MIN. WITHSTAND 5 MIN. WITHSTAND ENT CONTINUOUS ENT INTERRUPTING SYM. .625" DIA. HARDWARE (4)-SUPPLIED BY USER ENCLOSURE 2.19 56MM TYP. WAY ENTRANCES 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 1 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 2 15.5KV 110KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 PRINT IDENTIFICATION 6 25.00 [635] VS20-376-12-4FA ADJUSTABLE ENCLOSURE MOUNTING UP TO 21.75 [552] 26.63 [676] ENCLOSURE MOUNTING Dimensions are approximate. Do not use for construction. CHANGE 204309 CL 31.00 3.00 [76] FRONT REVISIONS DATE 6-5-14 Voltage (kv) 31.00 [787] HEIGHT 43” (1078mm) DRAWING REVIEW TEAM REVISIONS REV. 53. [136 Two-way Trident Solid Dielectric Switches Front Access with SafeVu Switch Series DRAWING REVIEW TEAM SH JQ REVISIONS VX REV. CHANGE A B C 187586 BSN 189834 JXU 195152 SH DATE 1-15-14 2-13-14 3-20-14 SWITCH ELECTRICAL INFORMATION SEE NOTES FOR LIMITATIONS WIDTH 26” (658mm) DEPTH 24” (603mm) One-line Diagram Model 15.5 95 34 53 630 630 20 20 12.5 MAXIMUM DESIGN VOLTAGE IMPULSE LEVEL ( BIL ) AC 1 MIN. WITHSTAND DC 15 MIN. WITHSTAND CURRENT CONTINUOUS CURRENT INTERRUPTING SYM. MOMENTARY CURRENT RMS ASYM. MAKING CURRENT RMS ASYM. 1 SEC. RATING RMS SYM. Voltage (kv) KV KV KV KV AMP AMP KA KA KA Catalog Number 3 VL21-376-20-3FAVU 15THREE LINE DIAGRAM HEIGHT 34” (861mm) SWITCH WEIGHT 750 LBS / 340 KG 4 VS20-376-12-4FAVU ENTRANCES WAY 1 15.5KV 95KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 2 15.5KV 95KV BIL 600A DEADBREAK APPARATUS BUSHING PER IEEE 386 FIGURE 11 61.26 [1556] 39.00 [991] FRONT SIDE 3.81 [97] 33.00 [838] Dimensions are approximate. Do not use for construction. 82.00 [2083] 3.00 [76] TYP. 3.00 [76] TYP. 2.19 [56] TYP. 34.63 [879] ENCLOSURE MOUNTING G & W E L34.00 ECTRIC [864] PA G E 1 5 2.19 [56] TYP. Components for Three Phase Switches Overcurrent Protection Fault interrupters are equipped with an encapsulated 500:1 or 1000:1 current transformer and a G&W self powered Vacuum Interrupter Control. Alternately, a wide variety of protective relay packages are available, including relays from SEL and other leading relay suppliers. Motor Actuator Automation begins with the addition of motor actuators to a manual switch. These actuators can be factory installed for new equipment or retrofitted to switchgear installed in the field. (Refer to the Motor Operator catalog, MO11, for motor control options.) External CTs and External PTs Metering or relaying accuracy current and potential transformers are available for use with protective relay packages. Operating Handle G&W will select the appropriate handle based on the application. Handles are operable via hook stick or rope rigging. Key Interlocks Key interlocks may be used to ensure safe coordination of equipment. All Trident ways can be equipped with provisions for key interlocks. Key interlocks can be provided, and factory installed if required. p Key interlock Auxiliary Contacts Auxiliary contacts are mounted internal to the mechanism housing to provide remote indication of switch contact position. One normally open and one normally closed Form C contact is provided. A junction box is available with terminal strip connections for up to four auxiliary contacts. G&W ELECTRIC PA G E 1 6 p Side mounted motor actuator Overcurrent Protection Options Type Trip Selection Enclosure Rating User Interface Settings Available Type 1.0 Single or Three Phase NEMA 4X* Knobs Phase Only Type 2.0 Three Phase NEMA 4X* Knobs Phase and Ground NEMA 4X* Via computer using a programming port, or manually via the pushbuttons on the front panel Phase and Ground Available as EZset or Plus Phase and Ground Available as EZset or Plus Notes Type 3.1 Single or Three Phase Type 4.1 NEMA 4X Single or Three Phase NEMA 4X Computer using a Programming Port Type 4.1 IP68 Single or Three Phase IP68 (submerged in 20’ of water for 20 days) Computer using a Programming Port Phase and Ground Available as EZset or Plus Type 7.1 Single or Three Phase IP68 (located within the mechanism housing) Computer using a Programming Port Phase and Ground Available as EZset or Plus * Optional clear lid enclosure available (shown above on Type 2) G&W ELECTRIC PA G E 1 7 Single Phase Trident solid dielectric insulated switches provide the total life cycle cost and operational benefits of fuseless, electronically controlled, resettable overcurrent protection, with the safety and maintenance benefits of an environmentally friendly dead-front design. The Trident utilizes G&W’s time proven, submersible epoxy insulation to fully encapsulate load and fault interrupting vacuum interrupters. This solid dielectric insulation eliminates the degradation of dielectric integrity commonly associated with oil insulated switchgear. Single Phase Trident single phase, spring-assisted switchgear is available for load break or fault interrupting switching. The compact units are ideal for switching residential loops and for oil fuse cutout replacements. Fault protection can be provided using a vacuum interrupter with an integral current transformer and a variety of overcurrent controls. The Single Phase Trident is available in a Front Access design, with operating handles and bushings on the same side of the switch. The switch can be mounted in any orientation to best meet the requirements of the application. Additional Features Visible Break — The single phase Trident is available with G&W’s SafeVu feature at 15kV, which provides an integrated visible break disconnect switch in series with the vacuum interrupter. This eliminates the need to remove elbows or use externally mounted linkage systems to provide a visible open. Switches equipped with the SafeVu feature incorporate redundant mechanical interlocks to ensure the load break switch is open prior to the operation of the visible break switch. p Single phase Trident switch Testing Trident switches are designed and tested to applicable standards including IEEE C37.74 (IEEE C37.71 and C37.72), IEEE 386, IEC 60265, and IEEE 592. All fault interrupter devices have passed IEEE C37.60. Trident switches are RUS accepted. Fully encapsulated current transformers provide power and sensing for G&W’s solid state electronic controls. The controls emulate the most common time current curves (TCC) for power fuses, mechanical relays, and fuse links. Features and Benefits Features Benefits No maintenance or monitoring system, lowest total life cycle costs Epoxy Insulation (No oil or SF6, and true dead-front design) Dead-front design provides increased operator safety by eliminating all exposed live parts Epoxy is inert, environmentally friendly, with no EPA usage restrictions Resettable Vacuum Interrupter Mechanism No fuses or fuse links to stock and replace Integral self-powered overcurrent protection available Integrated solution with fully encapsulated current transformers and no external power source or PT required G&W ELECTRIC PA G E 1 8 n 20 [510] NIMUM SIZE 4) Single Phase Single Phase Trident Switch Series Ratings 12” (305mm) 10” (254mm) Load Break & Fault Interrupting Ratings Voltage Class 15kV * 25kV Max System Voltage 15.5kV 27kV BIL Impulse 110kV † 125kV Continuous Current 630A 630A Load Break Current 630A 630A AC Withstand, 1 minute 35kV 60kV AC Withstand, Production, 1 minute 34kV 40kV DC Withstand, 15 minutes 53kV 78kV Momentary Current, RMS, asym 20kA 20kA Fault-Close 3-times, asym 20kA 20kA Fault Interrupting Current, sym 12.5kA 12.5kA 1 Second Current, sym 12.5kA 12.5kA Load Break Switch Mechanical Operations 2,000 2,000 35” (889mm) 7.5” (191mm) 13” (312mm) SIDE FRONT Single Phase Trident with SafeVu (*) SafeVu available on 15kV load break and single phase fault interrupters. (†) BIL impulse rating is 95kV when using SafeVu feature. 25” (614mm) 15” (381mm) Catalog Numbering Model One-line Diagram 3 36” (909mm) 4 Voltage (kv) Catalog Number 15 VL21-176-20-3FA 25 VL21-186-20-3FA 15 VS20-176-12-4FA 25 VS20-186-12-4FA Catalog Numbering with SafeVu Feature 8.6” (219mm) Model One-line Diagram Voltage (kv) 3 SIDE FRONT Catalog Number VL21-176-20-3FAVU 15 4 Approximate Weight = 75 lbs. (34 kg) CHARGING VALVE with SafeVu feature = 150 lbs. (68 kg) VS20-176-12-4FAVU CHARGING VALVE Dimensions are approximate. Do not use for construction. PRINT IDENTIFICATION DATE OVERCURRENT CONTROL OVERCURRENT CONTROL CONNECTORIZED CONNECTORIZED CABLE FEEDTHRU CABLE FEEDTHRU CUSTOMER (15 FEET OF CABLE) DATE CUSTOMER PRINT IDENTIFICATION G&W NO. G&W NO. G&W ELECTRIC PA G E 1 9 G&W offers Technical Support and Services: Custom Engineering Our engineers can tailor our products to meet the needs of any application. Custom Programming Our automation engineers can provide tailored relay programs to meet any specified needs. Factory Acceptance Testing G&W’s Factory Acceptance Testing ensures customers’ automation solutions are certified to operate properly and meet all requirements prior to being installed in the field. Training Services G&W offers a range of training solutions at both G&W facilities and on site. 24 Hour Technical Support Technical support for G&W products is available 24 hours a day, 7 days a week. For more information: gwelec.com General inquiries by email: info@gwelec.com Find your local sales representative: gwelec.com Tel 708.388.5010 Fax 708.388.0755 Catalog S-vsd16 January, 2016