10–120 Three-Phase Energy Analyzer, Three-Phase Power Logger Fluke Three-Phase Energy Analyzer Part No. Features 0721102 Measurement range Volt Vrms (ac+dc) 1 V to 1000 V phase to neutral Voltage Crest Factor (CF) 1.0 > 2.8 Amps (accuracy excluding clamp accuracy) Amps (ac +dc) 5 A to 6000 A 0.5 A to 600 A A Crest Factor (CF) 1 to 10 Hz @ 50 Hz nominal 42.50 Hz to 57.50 Hz @ 60 Hz nominal 51.00 Hz to 69.00 Hz Power Watts (VA, var) max 6000 MW Power factor 0 to 1 Energy kWh (kVAh, kvarh) Energy loss Harmonics Harmonic order (n) ElEctrical Phase Angle Unbalance Volts Amps Depends on clamp scaling and V nominal Depends on clamp scaling and V nominal Accuracy ± 0.5% of nominal voltage ±5% ± 0.5% ± 5 counts ± 0.5% ± 5 counts ±5% ± 0.01 Hz ± 0.01 Hz ± 1% ± 10 counts ± 0.1% @ nominal load ± 1% ± 10 counts Part No. Input Characteristics Input impedance Voltage rating Volt/Amps/Hertz True-rms voltage (AC+DC) True-rms current (AC+DC) Frequency CF Crest Factor Power W, VA, VAR Reactive Power 1-phase and 3-phase, 3 conductor balanced loads PF Power Factor DPF Displacement Power Factor Hz Frequency fundamental Harmonics Volts, Amps, Watts ± 0.1 % ±1% 0712553 Ranges 1 MΩ, 20 pF 600 Vrms, CAT III Accuracy 5.000 V, 50.00 V, 500.0 V, 1250 V* 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA 10.0 Hz to 15.0 kHz 1.0 to 10.0 ± (1 % + 10 counts) ± (0.5 % + 2 counts) ± (5 % + 1 count) 250 W 2.50 kW, 25.0 kW, 250kW, 2.50 MW, 25 MW, 250 MW, 625 MW, 1.56 GW 0.00 to 1.00 0.00 to 0.25 0.25 to 0.90 0.90 to 1.00 40.0 to 70.0 Hz ± (2 % + 6 counts) Total Power 1-phase and 3-phase, 3 ± (4 % + 4 counts) Fundamental Power ± 0.04 not specified ± 0.04 ± 0.03 ± (0.5 % + 2 counts) Fundamental V, A ± (3 % + 2 counts), W ± (5 % + 2 counts) V, A ± (5 % + 3 counts), W ± (10 % + 10 counts) V, A ± (15 % + 5 counts), W ± (30 % + 5 counts) ± 0.25 Hz 2nd (± 3°) … 51st (± 15°) ± (1 % + 10 counts) 32 to 51st Harmonic Frequency of fundamental Phase K-Factor(Amps&Watts) THD Sags & Swells Recording times (selectable) Vrms actual, Vrms max, Arms actual, Arms max, min (AC + DC) If you can’t find it on our shelves or in our catalog, we’ll make it for you at one of our manufacturing locations 43B 2 to 31st Harmonic ± 1% ± 10 counts Excluding line resistance accuracy DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7 0.0 % to 100 % ±5% -360° to +0° ± n x 1° 0.0 % to 20.0 % 0.0 % to 20.0 % Fluke Three-Phase Power Logger 434-II Recording Recording times (selectable) Parameters V/A/Hz Power Harmonics Ohms Temperature Scope Transients Minimum pulse width Useful bandwidth input Number of transients Voltage threshold settings 40 Hz to 70 Hz Volt&Amps(betweenFund.& Harmonic) Watts(betweenVoltFund.& Amps Harmonic ) 1.0 to 30.0 0.00 to 99.99 Fund (± 5°) … 51st (± 15°) ± 10 % ± (3% + 8 counts) 4 min to 16 days 5.000 V, 50.00 V 500.0 V, 1250 V* 50.00 A, 500.0 A, 5.000 kA, 50,00 kA Readings ± (2 % +10 counts) min (AC + DC) Cursor readings ± (2 % + 12 counts) Cursor Readings Average ± (2 % +10 counts) 4 min to 16 days Choose one or two parameters from one of the groups below Line Voltage, Current, Frequency Watts, VA, VAR, PF, DPF, Frequency THD,Volts(Fund.&Harmonic),Amps(F&H)Watts(F&H)Freq.(H), %(H) of total, Phase(H), KF Ohms, Diode, Continuity, Capacitance °C or °F DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor 40 ns DC to 1 MHz (with test leads TL24) 40 20 %, 50 %, 100 %, 200 % above or below reference signal For pricing and availability, contact your local Fastenal store or visit fastenal.com