passive infrared 0-10 volt dimming wall switch occupancy

advertisement
WATTSTOPPER
SENSORS OCCUPANCY AND VACANCY
PASSIVE INFRARED 0-10 VOLT DIMMING WALL SWITCH
OCCUPANCY SENSOR
Defaults to Manual-ON operation for
maximum energy savings
PW-311
Supports Partial-ON operation for energy
code compliance or incentives
Neutral Sense™ connection option with
break off tab to expose neutral terminals
120/277VAC and 347VAC models
Color-matched lens and
low profile for appealing design
Allows fully functional multi-way control
from up to four switch locations
Description
Partial-ON Option
­­­­­­­­ he PW-311 passive infrared (PIR) dimming wall switch sensor
T
can turn lights OFF and ON based on occupancy and allow the
user to increase or decrease the lighting level. It works with
0-10 VDC dimming drivers and ballasts to control lighting loads
including LEDs.
When set for Automatic-ON operation, the PW-311 typically
comes ON to the last non-zero light level for occupant comfort
and convenience. However, this default setting may be changed
to a fixed light level value of 50%, 75% or 100%. The dimmed
level options (Preset On Level) support new state and federal
energy code requirements.
Operation
The PW-311 installs in a single gang junction box with or
without neutral wiring. Factory default operation is for ManualON, so that users turn lights on only when needed. It uses PIR
technology to detect occupancy. Once the space is vacated
and the time delay elapses, lights automatically turn OFF. DIP
switch settings enable a variety of control options such as
Auto-ON operation, high and low trim, ramp up and fade down
times, power loss mode, smart light level, walk-through and
test modes. Multiple sensors may be used to dim a lighting load
from up to four locations.
Applications
The PW-311 sensor is ideal for enclosed spaces with clear line
of sight of the occupant. Common applications include small
offices, small conference rooms and lunch/break rooms. It
can be used for a two-wire or three-wire installation, either to
work with existing wiring, or to meet recent local or national
electrical code requirements. An easy-to-break plastic tab
covers neutral screw terminals. Once the sensor is connected
to neutral it complies with all codes that restrict current
leakage to ground.
Features
• Neutral Sense™ and optional neutral wiring simplifies 2011
NEC-compliant installation
• Test mode allows quick and easy verification of coverage
• Vandal resistant lens combines precise coverage with
durability
• LED indicates occupancy detection
• Presentation mode may be deactivated to allow Auto-ON
operation after 15 second time delay
• Optional Smart Light Level adapts ambient light hold off
threshold to meet user needs
• Selectable walk-through mode turns lights off three minutes
after the room is initially occupied if no motion is detected
after the first 30 seconds
WWW.LEGRAND.US/WATTSTOPPER
• Selectable audible and/or visual alerts for impending shutoff
• Service mode allows sensor to operate as a service switch in
the unlikely event of a failure
• Zero-crossing for long relay life
• No derating required for multi-gang applications
• Sensor coverage tested to NEMA Guide Publication WD 7-2000
• Compatible with decorator wall plates
• This product meets the material restrictions of RoHS
Specifications
• PW-311: 120/277VAC; 50/60Hz
• PW-311-347: 347VAC; 50/60Hz
• Dimming control signal: 0-10VDC, sinks up to 50mA for
control of compatible ballasts (12 if each sources 2mA);
Class 1 wiring
• Time delays: 3, 5, 15 or 30 minutes, walk-through, test-mode
• Power up after power loss: On, Off or last state
• Coverage: Major motion 35’ x 30’
Minor motion 20’ x 15’
• Sensitivity adjustment: PIR (high/low)
• Dimensions (L x W x D): 2.73” x 1.75” x 1.81” (69mm x 44mm
x 46mm)
• UL and cUL listed (E101196)
• Five year warranty
Installation and Wiring
Product Controls
DELAY
ADDITIONAL
FEATURES
Up Button
Down Button
MODE
Coverage Patterns
DIP Switch Settings
Dip Switches
Button
Hinges
Tabs
Detection LED
PIR Lens
Time
Additional
Time
Additional
Time
Additional
Delay
Features
Time
Additional
Delay
Features
Time
Additional
Time Delay
Additional
Features
Delay
Features
Delay
Features
Delay
Features
Exit Programming
Mode
ExitProgramming
Programming
Mode
Exit
Mode
Visual
Alert
Exit Programming
Mode
Visual
Alert
Visual
Alert
Visual
Alert
Visual
Alert
Audio
Alert
Visual
Audio
Alert
Audio
Alert
Audio
Alert
9
Audio
Alert
Walk-Thru
Audio
Alert
Walk-Thru
Walk-Thru
Walk-Thru
Mode
Walk-Thru
Mode
PIR
Sensitivity
Walk-Thru
Unused
PIR
Sensitivity
Unused
Mode Mode
PIR Sensitivity
Mode
PIRSensitivity
Sensitivity
Unused
Unused
Mode Unused
PIR
HighTrim
Trim
PIR Sensitivity
High
Unused
High
Trim
High
Trim
High
Trim
Mode 11
Low
Trim
High
Mode
Low
Trim
Mode
Low
Trim
1
Mode
Low
Trim
1
Mode
Low
Trim
1
Manual
-On
On 1
Ramp
UpTime
Time
Mode
Low
Trim
Manual
Ramp
Up
Manual
Up Time
Manual
On - On
RampRamp
UpTime
Time
Manual
- -On
Ramp
Up
Manual
-- -On
Auto
On
Fade
Down
Time
Ramp
Up Time
Time
Auto
On
Fade
Down
Auto
On
Fade
Down
Time
Auto- -On
On
Fade
Down
Time
Auto
Fade
Down
Time
Light
Level
Adjust
Auto - On
Fade
Down
Time
Light
Level
Adjust
Light
Level
Adjust
LightLevel
LevelAdjust
Adjust
Light
Light Level
Adjust
TimeDelay
Delay 22 33
Time
Time
PowerLoss
LossMode
Mode
TimeDelay
DelayDelay
Power
223332 3
Time
2
Time
Delay
Test/3
min
Power
Loss
PowerLoss
LossMode
ModeMode
Test/3
min
Power
Test/3
Power Loss
Mode
Test/3
min min
Test/3
min
5minutes
minutes
min
5Test/3
Presentation
Mode
5
minutes
Presentation
Mode
5
minutes
515
minutes
Presentation
Mode
minutes
5
minutes
Presentation
Mode
15
minutes
Presentation
Mode
ServiceMode
Mode
Presentation
15 minutes
Service
15
minutes
15
minutes
Service
Mode
30
minutes
15
minutes
Service
Mode
30
minutes
Service
Mode
Preset
On
Level
Service
Mode
30
minutes
Preset
On Level
30
minutes
30
minutes
Preset
On
Level
30
minutes
Preset
On
Level
Preset
OnOn
Level
Preset
Level
=ON =OFF
=OFF
=ON
=ON
=OFF
=ON
=OFF
=ON
Non-DimMode
Mode
Non-Dim
=ON =OFF
=OFF
Non-Dim
DefaultValues
ValuesShown
Shown
Non-Dim
ModeMode
Default
Non-Dim
Mode
ResetToTo
Default
Non-Dim
Mode
Default
Values
Shown
Reset
Default
Default
Values
Shown
Default
Values
Shown
inBold
Bold
To Default
Default
Values
Shown
ResetReset
Default
in
Reset
ToTo
Default
in Bold
Reset
To
Default
Bold
ininin
Bold
Bold
ONON
ON
ONON
ON
1 12 23 34 45 56 67 78 89 9
1 2 3 4 5 6 7 8
1 12 23 34 45 56 67 78 89 9
1 2 3 4 5 6 7 8 9
Major motion
AdditionalFeatures
Features 66 77 88 99 Green
GreenLED
LED# #ofofBlinks
Blinks
Additional
Additional
Features
# of Blinks
9 Green
Additional
Features
Green
LED##LED
ofBlinks
Blinks
Additional
Features
Green
LED
666777868897998
Exit
Programming
Mode
Additional
Features
Green
LED of
# of
Blinks
Exit
Programming
Mode
Minor motion
1=OFF,2=ON
2=ON
PIR
1=OFF,
1=OFF,
1=OFF,
2=ON2=ON
1=OFF,
2=ON
Coverage
1=ON,
2=OFF
1=OFF,
2=ON
1=ON,
2=OFF
2=OFF
1=ON,1=ON,
2=OFF
1=ON,
2=OFF
1=OFF,
2=ON
1=ON,
2=OFF
1=OFF,
2=ON
1=OFF,
1=OFF,
2=ON2=ON
1=OFF,
2=ON
1=100%,
2=50%
1=OFF,
2=ON
35’
1=100%,
2=50%
1=100%,
2=50%
(10.6m)
1=100%,
2=50%
1=100%,
1=10V,2=50%
2=Manual
Adjustment
1=100%,
2=50% Adjustment
1=10V,
2=Manual
1=10V,
2=Manual
Adjustment
1=10V,
2=Manual
Adjustment
1=10V,
2=Manual
Adjustment
1=0V,
1=10V,
2=Manual
Adjustment
1=0V,
2=Manual
Adjustment
1=0V,
2=Manual
Adjustment
1=0V,2=Manual
2=Manual
Adjustment
1=0V,
Adjustment
1=1,2=2.5,
2=2.5,3=5,
3=5,
4=10seconds
seconds
1=0V,
2=Manual
Adjustment
1=1,
4=10
1=1, 2=2.5,
3=5,
4=10
seconds
1=1,2=2.5,
2=2.5,
3=5,4=10
4=10
seconds
1=1,
3=5,
seconds
1=1,
2=2.5,
3=5,
4=10
seconds
1=2.5,
2=5,
3=15,
4=30
seconds
1=2.5,
2=5,
3=15,
4=30
seconds
1=2.5,
2=5,
3=15,
4=30
seconds
1=2.5,2=5,
2=5,3=15,
3=15,4=30
4=30seconds
seconds
1=2.5,
1=2.5,
2=5,
3=15,
4=30
seconds
1=Disable,
2=Enable,
1=Disable,
2=Enable,
1=Disable,
2=Enable,
1=Disable,
2=Enable,
1=Disable,
2=Enable,
3=SmartLight
Light
Level
3=Smart
Level
1=Disable,
2=Enable,
20’
3=Smart
Light
3=Smart
LightLevel
Level Level
3=Smart
Light
(6.1m)
3=Smart
Light
Level
1=KeepLast
LastState,
State,
1=Keep
1=Keep
Last
State, Off
1=Keep
Last
State,
1=Keep
Last
State,
2=Default
On,
3=Default
2=Default
On,
3=Default
Off
1=Keep
Last
State,
2=Default
On, 3=Default
2=Default
On,3=Default
3=Default
Off Off
2=Default
On,
Off
2=Default
On, 3=Default
Off
1=ON,2=OFF
2=OFF
1=ON,
1=ON,
2=OFF
1=ON,
2=OFF
1=ON,
2=OFF
1=OFF,
2=ON
1=ON,
2=OFF
1=OFF,
2=ON
1=OFF,
2=ON
1=OFF,
2=ON
1=OFF,
2=ON
1=Last
Non-Zero
Value,
1=OFF,
2=ON
1=Last
Non-Zero
Value,
1=Last
Non-Zero
Value,
1=Last
Non-Zero
Value,
1=Last
Non-Zero
Value,
2=50%,
3=75%,
4=100%
2=50%,
3=75%,
4=100%
1=Last
Non-Zero
Value,
2=50%,
3=75%,
4=100%
2=50%,
3=75%,
4=100%
2=50%,
3=75%,
4=100%
15’
2=50%,
3=75%,
1=OFF,2=ON
2=ON 4=100%
1=OFF,
(4.5m)
1=OFF,
1=OFF,
2=ON2=ON
1=OFF,
1=OFF,
2=ON
Press2=ON
and
HoldUP
UPoror
Press
and
Hold
4’
Press
and
Hold
UP
or
Press
andHold
Hold
UPoror
Press
and
UP
DOWN
for
5seconds
seconds
DOWN
for
5 for
Press
and
Hold
or
(1.2m)
DOWN
5UP
seconds
DOWN
for5 5seconds
seconds
DOWN
for
DOWN
for 5 seconds
7.5’
(2.2m)
For best performance, Legrand recommends using
this sensor in spaces no larger than 15’ x 12’.
8" flying leads for
line, load, ground
and multi-way
connections
0-10V
Dimming
Grey
Violet
Yellow
Red
Black
Line
Breakaway
tab
Green
Simple optional neutral connection for
2-wire or 3-wire installation
Black
Green
Yellow
Optional neutral
terminals behind
breakaway tab
35’
(10.6m)
20’
(6.1m)
0
Wiring Diagrams
Violet
Gray
Red
Driver
or Ballast
Neutral
(optional)
Ground
Violet
Gray
Black
Yellow
traveler
Yellow
Red
Black
Green
Neutral
(optional)
Ground
Neutral
Connect 0-10V
leads to dimming
ballast from one
PW-311 only
Line
Violet
Gray
Red
Green
Driver
or Ballast
Neutral
(optional)
Ground
Neutral
Note: Requires Class 1 wiring for 0-10V dimming.
Multi-way wiring
Ordering Information
Catalog #
Color
Voltage
Load Rating
PW-311-W
White
120VAC; 50/60Hz
PW-311-LA
Lt. Almond
@ 120VAC: 0-1000W ballast, E-ballast, LED,
tungsten; 1/4hp motor
PW-311-I
Ivory
PW-311-G
Grey
PW-311-B
Black
PW-311-R
Red
PW-311-347-W
White
PW-311-347-LA
Lt. Almond
PW-311-347-I
Ivory
PW-311-347-G
Grey
PW-311-347-B
Black
PW-311-347-R
Red
or
277VAC; 50/60Hz
347VAC; 50/60Hz
or
@ 277VAC: 0-1200W ballast, E-ballast, LED;
1/4hp motor
0-1500W ballast, LED; 1/4hp motor
Order wall plate separately.
WWW.LEGRAND.US/WATTSTOPPER
Pub. No. 44302 Rev. 5/2016