Quick selector reference guide Frequently used distribution and control products available from distributor stock Table of contents Pow-R-Stock panelboards Questions to ask...................................... 5 Catalog numbering................................... 6 Interiors, EZ Boxes and EZ Trims.............. 8 Branch circuit breakers............................. 10 Main circuit breakers................................ 11 Lug kits and accessories.......................... 14 Safety switches/ disconnects Questions to ask....................................15 Catalog numbering.................................16 General-duty safety switches.................17 Heavy-duty safety switches...................18 Safety switch kits...................................19 Transformers Questions to ask................................... 20 Catalog numbering................................ 21 General-purpose transformers............... 23 Sizing tables.......................................... 25 2 EATON www.eaton.com Enclosed control Questions to ask........................................ 26 Catalog numbering..................................... 27 NEMA non-combination, non-reversing starters, Type 1.................... 27 NEMA combination, non-reversing starters, non-fusible disconnect, Type 1..... 27 NEMA accessories...................................... 28 Lighting contactors..................................... 29 Pushbutton stations and pushbuttons Questions to ask...................................... 30 30 mm pushbutton stations..................... 31 22 mm pushbutton stations..................... 31 Individually packaged 30 mm pushbuttons and operators...................... 32 EATON www.eaton.com 3 Manual starters Questions to ask................................................................ 33 Manual motor switches without overload.......................... 34 Single-phase manual starter with overload protection....... 34 Single- and three-phase manual starters with overload protection...................................................... 34 Surge protection Questions to ask...................................... 35 Catalog numbering................................... 36 Distribution panel surge protection.......... 37 CVX accessories....................................... 37 Control panel surge protection................. 37 SP1 accessories....................................... 37 4 EATON www.eaton.com Questions to ask Step 1 Q Select an interior What is your voltage? A —120/240 V single-phase, three-wire —208Y/120 V three-phase, four-wire —240 V three-phase, three-wire —480Y/277 V three-phase, four-wire Q What is your busbar rating? Q What is the number of branch circuits/poles? A A —100 A (aluminum or copper) —225 A (aluminum or copper) —400 A (aluminum or copper) —18 —30 —42 Step 2 Q Step 3 Q Step 4 Q Step 5 Q Enclosure type What enclosure is required? A —NEMAT 1 indoor —NEMA 3R outdoor Trim type For NEMA 1 indoor panels, will the panel be mounted recessed in the wall or mounted directly to the wall? A —Flush —Surface What is the cable entry locations for the incoming feeder? A —Top —Bottom Main device Main lugs only (MLO) or main circuit breaker? A —MLO —MCB (choose amperage and top or bottom) Pow-R-Stock panelboards (unassembled) EATON www.eaton.com 5 Catalog numbering system— Pow-R-Stock panelboard interiors PRL1A 1 225 X 42 A S Panel type PRL1A = PRL1a PRL2A = PRL2a Main device Phase 1 = Single-phase 3 = Three-phase X indicates no main/ use main breaker or main lug kit Number of circuits 18, 30 and 42 Bus amperes 100 = 100 A 225 = 225 A 400 = 400 A Bus type A = Aluminum bus C = Copper bus Option S = Short—no TFL or SFB provisions Special note: This option applies only to 42 circuit 225 A interiors. Note: Top-feed provision for main lugs or main breaker, no provision for through-feed lugs or sub-feed breaker. 6 EATON www.eaton.com Catalog numbering system— EZ Panel factory-assembled stock panelboards A P1 3 225 T E T 30 C S Assembled A=Assembled completely by factory Trim type F =Flush A S =Surface W =Weatherproof (NEMA 3R) Panel type Bus type P1 = PRL1a P2 = PRL2a A = Aluminum C = Copper Phase 3 = Three-phase Number of circuits 30 = 30 circuits 42 = 42 circuits Main lug/breaker amperes 100 = 100 A A 225 = 225 A 150 = 150 A 400 = 400 A 200 = 200 A Incoming location B=Bottom A T=Top Sub-feed device F =Sub-feed breaker provision T=Through-feed lugs Main device E=Main breaker ED F =Main breaker FD H=Main breaker HFD H=Main breaker HKD at 400 A K=Main breaker KD L =Main lug A These items are not part of the initial launch. Please consult VISTA or your Eaton sales engineer for product availability. NNotes: Not all combinations may be valid. Please verify availability of catalog number created. Refer to PA014007EN for more information on the EZ Panel. EATON www.eaton.com 7 Pow-R-Stock panelboards—EZE Boxes and EZ Trims Capability Max. Ampere number rating of poles Main lugs Catalog numbers Sub-feed Main Through- breaker breaker feed lugs (225 A max.) Interiors (less main device) Boxes Trims (NEMA 1) Aluminum bus Copper bus NEMA 1 Surface Flush NEMA 3R enclosures Single-phase, three-wire 120/240 Vac 100 18 n n n N/A PRL1A1100X18A PRL1A1100X18C EZB2036R EZT2036S EZT2036F GWPBQ2036PR 100 30 n n n 100 PRL1A1100X30A PRL1A1100X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 100 42 n n n N/A PRL1A1100X42A PRL1A1100X42C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 30 n n n 100, 125, 150, 175, 200, 225 PRL1A1225X30A PRL1A1225X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n n N/A N/A PRL1A1225X42AS A PRL1A1225X42CS A EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n n n 100, 125, 150, 175, 200, 225 PRL1A1225X42A PRL1A1225X42C EZB2060R EZT2060S EZT2060F GWPBQ2060PR 400 42 n n n 100, 125, 150, 175, 200, 225 PRL1A1400X42A PRL1A1400X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n N/A PRL1A1600X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 PRL1A1600X42CL EZB2090R EZT2090S EZT2090F GWPBQ2090PR Three-phase, four-wire 208Y/120 Vac 100 18 n n n N/A PRL1A3100X18A PRL1A3100X18C EZB2036R EZT2036S EZT2036F GWPBQ2036PR 100 30 n n n 100 PRL1A3100X30A PRL1A3100X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 100 42 n n n N/A PRL1A3100X42A PRL1A3100X42C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 30 n n n 100, 125, 150, 175, 200, 225 PRL1A3225X30A PRL1A3225X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n N/A N/A N/A PRL1A3225L42AS PRL1A3225L42CS EZB2042R EZT2042S EZT2042F GWPBQ2042PR 225 42 n n N/A N/A PRL1A3225X42AS A PRL1A3225X42CS A EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n n n 100, 125, 150, 175, 200, 225 PRL1A3225X42A PRL1A3225X42C EZB2060R EZT2060S EZT2060F GWPBQ2060PR 400 42 n n n 100, 125, 150, 175, 200, 225 PRL1A3400X42A PRL1A3400X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n N/A PRL1A3600X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 PRL1A3600X42CL EZB2090R EZT2090S EZT2090F GWPBQ2090PR Three-phase, four-wire 480Y/277 Vac 100 18 n n n N/A PRL2A3100X18A PRL2A3100X18C EZB2036R EZT2036S EZT2036F GWPBQ2036PR 100 30 n n n 100 PRL2A3100X30A PRL2A3100X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 100 42 n n n N/A PRL2A3100X42A PRL2A3100X42C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 30 n n n 100, 125, 150, 175, 200, 225 PRL2A3225X30A PRL2A3225X30C EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n N/A N/A N/A PRL2A3225L42AS PRL2A3225L42CS EZB2042R EZT2042S EZT2042F GWPBQ2042PR 225 42 n n N/A N/A PRL2A3225X42AS A PRL2A3225X42CS A EZB2048R EZT2048S EZT2048F GWPBQ2048PR 225 42 n n n 100, 125, 150, 175, 200, 225 PRL2A3225X42A PRL2A3225X42C EZB2060R EZT2060S EZT2060F GWPBQ2060PR 400 42 n n n 100, 125, 150, 175, 200, 225 PRL2A3400X42A PRL2A3400X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n N/A PRL2A3600X42C EZB2072R EZT2072S EZT2072F GWPBQ2072PR 600 42 n n n 100, 125, 150, 175, 200, 225, 250, 300, 350, 400 PRL2A3600X42CL EZB2090R EZT2090S EZT2090F GWPBQ2090PR A S = Short—no TFL or SFB provisions. NNote: The colors shown in the tables correspond to the color coding on the trim, interior and box product packaging labels. Be sure that all three parts match when delivering to your customer. NNote: Distributors can purchase boxes in quantities via the Distributor toolbox. 8 EATON www.eaton.com EATON www.eaton.com 9 Branch circuit breakers Summary of branch breakers available No. of Breaker poles Ampere rating Voltage kAIC rating Example Panel type BAB AB 1 2 2 3 QBAF 1 QBHAF 1 QBCAF 1 QBHCAF 1 QBGFT 1 2 QBHGFT 1 2 QBGFEP 1 2 QBHGFEP 1 2 QBHW A 1 2 2 3 GHQ A 1 GHB AB 1 2 3 15–70 15–100 15–100 15–100 15–20 15–20 15–20 15–20 15–40 15–50 15–30 15–30 15–40 15–50 15–30 15–30 15–70 15–100 15–100 15–100 15–20 15–100 15–100 15–100 10 10 10 10 10 22 10 22 10 10 22 22 10 10 22 22 22 22 22 22 14 14 14 14 BAB1020 BAB2020 BAB2040H BAB3030H QBAF1020 QBHAF1020 QBCAF1020 QBHCAF1020 QBGFT1020 QBGFT2040 QBHGFT1020 QBHGFT2020 QBGFEP1020 QBGFEP2020 QBHGFEP1020 QBHGFEP2020 QBHW1020 QBHW2020 QBHW2040H QBHW3030H GHQ1020 GHB1020 GHB2040 GHB3060 PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL2a PRL2a PRL2a PRL2a 120 120/240 240 240 120 120 120 120 120 120/240 120 120/240 120 120/240 120 120/240 120 120/240 240 240 277 277 480Y/277 480Y/277 A BAB, QBHW, GHQ and GHB breakers installed in PRL1a and PRL2a are available with shunt trip, i.e., BAB1020S. B BAB-H and GHB 70–100 A available as chassis-mounted main device. 10 EATON www.eaton.com Main circuit breaker kits Kits—main circuit breaker (includes circuit breaker and terminals) Max. Ampere volt. rating Service 240 Vac 100 125 150 175 200 225 240 Vac 100 125 150 175 200 225 480 Vac 100 110 125 150 175 200 225 480 Vac 100 110 125 150 175 200 225 Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Wire range Breaker Mounting AI/Cu Catalog frame location (in kcmil) number ED Top (1) #14–1/0 BKED100T ED Top (1) #4–4/0 BKED125T ED Top (1) #4–4/0 BKED150T ED Top (1) #4–4/0 A BKED175T ED Top (1) #4–4/0 A BKED200T ED Top (1) #4–4/0 A BKED225T ED Bottom (1) #14–1/0 BKED100B ED Bottom (1) #4–4/0 BKED125B ED Bottom 1) #4–4/0 BKED150B ED Bottom (1) #4–4/0 A BKED175B ED Bottom (1) #4–4/0 A BKED200B ED Bottom (1) #4–4/0 A BKED225B FD Top (1) #14–1/0 BKFD100T FD Top (1) #4–4/0 BKFD110T FD Top (1) #4–4/0 BKFD125T FD Top (1) #4–4/0 BKFD150T FD Top (1) #4–4/0 A BKFD175T FD Top (1) #4–4/0 A BKFD200T FD Top (1) #4–4/0 A BKFD225T FD Bottom (1) #14–1/0 BKFD100B FD Bottom (1) #4–1/0 BKFD110B FD Bottom (1) #4–4/0 BKFD125B FD Bottom (1) #4–4/0 BKFD150B FD Bottom (1) #4–4/0 A BKFD175B FD Bottom (1) #4–4/0 A BKFD200B FD Bottom (1) #4–4/0 A BKFD225B A Order optional lug kit catalog no. 3TA225FDK for 175–225 A ED- and FD-Frame three-pole circuit breakers to provide terminations for (1) #6–300 kcmil. EATON www.eaton.com 11 Main circuit breaker kits Kits—main circuit breaker (includes circuit breaker and terminals) Max. Ampere volt. rating Service 480 Vac 100 110 125 150 175 200 225 480 Vac 100 110 125 150 175 200 225 480 Vac 250 300 350 400 480 Vac 250 300 350 400 Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Wire range Breaker Mounting AI/Cu frame location (in kcmil) Catalog number HFD Top (1) #14–1/0 BKHFD100T HFD Top (2) #4–4/0 BKHFD110T HFD Top (2) #4–4/0 BKHFD125T HFD Top (2) #4–4/0 BKHFD150T HFD Top (2) #4–4/0 BKHFD175T HFD Top (2) #4–4/0 BKHFD200T HFD Top (2) #4–4/0 BKHFD225T HFD Bottom (1) #14–1/0 BKHFD100B HFD Bottom (2) #4–4/0 BKHFD110B HFD Bottom (2) #4–4/0 BKHFD125B HFD Bottom (2) #4–4/0 BKHFD150B HFD Bottom (2) #4–4/0 BKHFD175B HFD Bottom (2) #4–4/0 BKHFD200B HFD Bottom (2) #4–4/0 BKHFD225B KD Top (1) 250–500 BKKD250T KD Top (1) 250–500 BKKD300T KD Top (1) 250–500 BKKD350T KD Top KD Bottom (2) 3/0–250 BKKD400T or (1) 3/0–500 (1) 250–500 BKKD250B KD Bottom (1) 250–500 BKKD300B KD Bottom (1) 250–500 BKKD350B KD Bottom (2) 3/0–250 BKKD400B or (1) 3/0–500 NNote: KD kits are to be used on 400 A panels only. 12 EATON www.eaton.com Main circuit breaker kits Kits—main circuit breaker (includes circuit breaker and terminals) Max. Ampere volt. rating Service 480 Vac 250 300 350 400 480 Vac 250 300 350 400 480 Vac 400 500 600 480 Vac 400 500 600 Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Single- or three-phase Wire range Breaker Mounting AI/Cu frame location (in kcmil) Catalog number HKD Top (1) 250–500 BKHKD250T HKD Top (1) 250–500 BKHKD300T HKD Top (1) 250–500 BKHKD350T HKD Top (1) 250–500 BKHKD400T HKD Bottom (1) 250–500 BKHKD250B HKD Bottom (1) 250–500 BKHKD300B HKD Bottom (1) 250–500 BKHKD350B HKD Bottom (1) 250–500 BKHKD400B LG Top (1) #2–500 BKLGE400T LG Top (2) #2–500 BKLGE500T LG Top (2) #2–500 BKLGE600T LG Bottom (1) #2–500 BKLGE400B LG Bottom (2) #2–500 BKLGE500B LG Bottom (2) #2–500 BKLGE600B EATON www.eaton.com 13 Lug kits and accessories Standard main/sub-feed breaker lug capacities Ampere rating Lug wire range Al/Cu 100 125–225 250–350 400 (1) #14–1/0 (1) #4–4/0 (1) 250–500 kcmil (2) 3/0–250 kcmil or (1) 3/0–500 kcmil Main/through-feed lug kits Ampere rating Wire range Al/Cu Catalog number 100 225 400 600 (1) #14–1/0 (1) #6–300 kcmil (2) #2–500 kcmil (2) #2–500 kcmil LUGKIT100 LUGKIT225 LUGKIT400 LUGKIT600 Kits Catalog number Description 100 A 225 A 400/600 A Service entrance kit 200% neutral kit Sub-feed breaker adapter (used to mount 225 A sub-feed breaker in 400 A panels) Sub-feed breaker adapter (used to mount 225 A sub-feed breaker in 600 A panels) Sub-feed breaker adapter (used to mount 400 A sub-feed breaker in 600 A panels) SEK1/2 2NK100 — SEK1.2 2NK225 — SEK4/6 1NK400 225ASFBKIT — — 225BSFBKIT — — 400ASFBKIT Accessories Description Catalog number Isolated ground bar kit Copper ground bar kit 1P filler plate A Series rating kit B ISOGROUND CUGROUND 5155C62H01 SRK A Each PRS panel comes with 50% filler plates, e.g., 18 circuit interior contains 9 filler plates. B Series rating kit includes series rating book and adhesive sleeve and series rating sticker. If panelboard is being series rated higher than the base rating, an SRK is required. 14 EATON www.eaton.com Questions to ask Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Q Which type of switch do you need? Q What current (ampere) rating do you need? Q Should it be fused, non-fused or fusible with neutral? Q How many poles? Q Choose the maximum circuit voltage. Q What type of enclosure do you need? A A A A A A —Heavy-duty (DH) —General-duty (DG) —Double-throw (DT) —30, 60, 100, 200, 400, 600, 800, 1200 —F = Fusible without neutral —U = Non-fusible —N = Fusible with neutral —1, 2, 3, 4, 6 — 240 Vac — 600 Vac —NEMA 1 —NEMA 3R —NEMA 12 —NEMA 4 painted steel —NEMA 4X stainless steel —NEMA 4X non-metallic Safety switches/ disconnects EATON www.eaton.com 15 Catalog numbering system—safety switches DH 3 6 1 N D K Switch type DG = Generalduty DH = Heavy-duty DT = Double-throw Fusible/non-fusible or neutral F = Fusible without neutral U = Non-fusible N = Fusible with neutral Poles/blades 1 = 1 pole 2 = 2 poles 3 = 3 poles 4 = 4 poles 6 = 6 poles NEMA enclosure ratings C = NEMA 4X Non-metallic G = NEMA 1 P = NEMA 4 Painted steel R = NEMA 3R W = NEMA 4X Stainless steel Voltage 1 = 120 Vac 2 = 240 Vac 6 = 600 Vac Amperes 1 = 30 A 2 = 60 A 3 = 100 A 4 = 200 A 5 = 400 A 6 = 600 A 7 = 800 A 8 = 1200 A 16 Series K = Design all general-duty switches above 200 A and all heavy-duty switches incorporate K-Series switch design B = Design general-duty 30–100 A EATON www.eaton.com General-duty safety switches (disconnects) Two-pole—240 Vac (suitable for service entrance use with a neutral or ground kit) Max. hp ratings Current rating (amps) Type Single-phase Enclosure Catalog type 120 Vac 240 Vac number 30 30 30 30 60 60 60 60 100 100 100 100 Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 3R NEMA 3R 2 2 3 1 1.5–3 3 1.5–3 3 3–10 10 3–10 10 7.5–15 15 7.5–15 15 DG221NGB DG221UGB DG221NRB DG221URB DG222NGB DG222UGB DG222NRB DG222URB DG223NGB DG223UGB DG223NRB DG223URB Three-pole—240 Vac (suitable for service entrance use with a neutral or ground lug kit) Max. hp ratings A Current rating (amps) 30 30 30 30 60 60 60 60 100 100 100 100 Type Single- Threephase phase Enclosure 240 Vac 240 Vac type Catalog number Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible Fusible with neutral Non-fusible NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 1 NEMA 1 NEMA 3R NEMA 3R DG321NGB DG321UGB DG321NRB DG321URB DG322NGB DG322UGB DG322NRB DG322URB DG323NGB DG323UGB DG323NRB DG323URB 1.5–3 3 1.5–3 3 3–10 10 3–10 10 7.5–15 15 7.5–15 15 3–7.5 7.5 3–7.5 7.5 7.5–15 15 7.5–15 15 15–30 30 15–30 30 A Maximum hp ratings for fusible units apply only when dual element time-delay fuses are used. Neutral and ground lug kits Description Catalog number Neutral kit for 30 A switches Neutral kit for 60–100 A switches Ground lug kit for 30–100 A switches DG030NB DG100NB DG030GB Class R fuse adapter kits Ampere rating Type Voltage Catalog number 30 60 100 General-duty General-duty General-duty 240 240 240 DG30RB DS16FK DG100RB EATON www.eaton.com 17 Heavy-duty safety switches (disconnects) Three-pole—480–600 Vac (suitable for service entrance use with a neutral or ground lug kit below) Max. hp ratings Current rating (amps) Type SingleThreephase phase Enclosure Catalog type 480 V 600 V 480 V 600 V number 30 30 30 30 30 30 60 60 60 60 60 60 100 100 100 100 100 100 200 200 200 200 200 200 NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 4X NEMA 4X NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 4X NEMA 4X NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 4X NEMA 4X NEMA 1 NEMA 1 NEMA 3R NEMA 3R NEMA 4X NEMA 4X Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible Fusible Non-fusible 7.5 7.5 7.5 7.5 7.5 7.5 20 20 20 20 20 20 30 30 30 30 30 40 50 50 50 50 50 50 15 15 15 15 10 10 30 30 30 30 25 25 60 60 60 60 40 50 125 125 125 125 50 50 10 10 10 10 15 20 25 25 25 25 30 50 40 40 40 40 60 75 50 50 50 50 125 125 20 20 20 20 20 30 50 50 50 50 50 60 75 75 75 75 75 100 150 150 150 150 150 125 DH361FGK A DH361UGK DH361FRK A DH361URK DH361FWK A DH361UWK DH362FGK DH362UGK DH362FRK DH362URK DH362FWK DH362UWK DH363FGK DH363UGK DH363FRK DH363URK DH363FWK DH363UWK DH364FGK DH364UGK DH364FRK DH364URK DH364FWK DH364UWK A For 30 A switches requiring Class J fusing, switch must be ordered with the Class J clips from the factory by adding a suffix “J” on the end. 18 EATON www.eaton.com Safety switch kits Neutral and ground lug kits A Description Catalog number Neutral kit for 30–60 A switches Neutral kit for 100 A switches Neutral kit for 200 A switches Ground lug kit for 30–100 A switches Ground lug kit for 200 A switches DH030NK DH100NK DG200NK DS100GK DS200GK A A factory-installed ground lug is supplied on all NEMA 4, 4X and 12 safety switches, as well as all 400 A and higher NEMA 1 and 3R safety switches. A factory-installed ground lug is also supplied on all heavy-duty NEMA 1 and 3R 30–200 A switches that do not have a factory installed neutral. Class R fuse adapter kits Ampere rating Type Voltage Catalog number 30 60 100 200 Heavy-duty Heavy-duty Heavy-duty Heavy-duty 600 600 600 600 DS16FK DS26FK DS36FK DS346FK Class J fuse adapter kit A Ampere rating Type Voltage Catalog number 60 Heavy-duty 600 DS26JK A 30 A switches must be ordered from the factory with Class J fuse provisions by adding suffix “J” at the end of the switch catalog number. 100 A and 200 A switches can be field modified by moving the load side fuse base. EATON www.eaton.com 19 Questions to ask Step 1 Step 2 Step 3 Step 4 Q How many phases? Q What type of enclosure is required? Q What is the primary voltage? (input voltage) Q What is the secondary voltage? (output voltage) A A A A —Single-phase —Three-phase —Ventilated —Encapsulated —Single-phase is 240 V x 480 V —Three-phase is 480 V delta (three-phase, three-wire) —Single-phase —120/240 —Three-phase —208Y/120 (three-phase, four-wire) or 240 V delta Step 5 Step 6 Q What kVA transformer is required? Q If a ventilated transformer was selected A A —If single-phase encapsulated, kVAs are: 0.05, 0.075, 0.1, 0.15, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 25, 37.5 —If single-phase ventilated, kVAs are: 15, 25, 37.5, 50, 75, 100, 167 —If three-phase encapsulated, kVAs are: 3, 6, 9, 15, 30, 45, 75 —If three-phase ventilated, kVAs are: 15, 30, 45, 75, 112.5, 150, 225, 300 —Field kits: lug kits or weathershields —Select from selection tables Transformers 20 EATON www.eaton.com Catalog numbering system—DOE 2016 ventilated transformers V 48 M 28 T 75 16 Type T=DS-3 (single-phase ventilated) V=DT-3 (three-phase ventilated) Primary voltage 20 = 240 x 480 A 48 = 480 Taps Phase S = Single-phase T = Three-phase kVA 15 = 15 25 = 25 A 30 = 30 37 = 37.5 A 45 = 45 D = 2@+2.5%, 2@–2.5% G = 2@–5% L = 2@–5%X 4@–2.5% M = 2@+2.5%,4@–2.5% N = None P = 1@+5%, 2@–5%X A 2@+2.5%,4@–2.5% 50 = 50 A 75 = 75 99 = 100 A 12 = 112.5 49 = 150 67 = 167 A 22 = 225 33 = 300 DOE 10 CFR 431.2016 16 = DOE 2016 efficiency Suffix options Blank=Aluminum windings CU =Copper windings ES =Shielded Secondary voltage 11 = 120/240 A 28 = 208Y/120 22 = 240 V delta with 120 V lighting tap A Typically used with single-phase transformers. EATON www.eaton.com 21 Catalog numbering system—encapsulated transformers S 20 N 11 S 05 A Type S=EP (single-phase encapsulated) Y=EPT (three-phase encapsulated) Phase and shield S = Single-phase T = Three-phase P = Epoxy potted B E = Shielded Primary voltage 20 = 240 x 480 A 48 = 480 Taps D = 2@+2.5%, 2@–2.5% G = 2@–5% L = 2@–5%X 4@–2.5% M = 2@+2.5%,4@–2.5% N = None P = 1@+5%, 2@–5%X A 2@+2.5%,4@–2.5% kVA 81 = 0.05 A 85 = 0.075 A 82 = 0.10 A 83 = 0.15 A 26 = 0.25 A 51 = 0.50 A 76 = 0.75 A 01 = 1 A 16 = 1.5 A 02 = 2 A 03 = 3 Secondary voltage 11 = 120/240 A 28 = 208Y/120 22 = 240 V delta with 120 V lighting tap 05 = 5 A 06 = 6 07 = 7.5 A 09 = 9 10 = 10 A 15 = 15 25 = 25 A 30 = 30 37 = 37.5 A 45 = 45 75 = 75 Model number Model number (A–Z) omitted when additional suffixes are used Suffix options Blank=Aluminum windings B =80 °C temperature rise CU =Copper windings A Typically used with single-phase transformers. B Single-phase 0.25–2 kVA encapsulated transformers only. 22 EATON www.eaton.com General-purpose transformers Three-phase ventilated, 480 delta—208 Y/120, 150 °C rise, aluminum windings, DOE 2016 kVA Frame number Wiring diagram Typical Weathershield lug kit Catalog number 15 30 45 75 112.5 150 225 300 939 940 940 942 943 943 944 945 280B 280B 280B 280B 280B 280B 280B 280B WS57 WS58 WS58 WS59 WS60 WS60 WS61 WS62 V48M28T1516 A V48M28T3016 A V48M28T4516 A V48M28T7516 B V48M28T1216 B V48M28T4916 B V48M28T2216 V48M28T3316 LKS1 LKS1 LKS1 LKS2 LKS2 LKS3 LKS3 LKS3 A Suitable for use with wall-mounted bracket WMB05. B Suitable for use with wall-mounted bracket WMB04. Three-phase ventilated, 480 delta—240/120 lighting tap, 150 °C rise, aluminum windings, DOE 2016 kVA Frame number Wiring diagram Typical Weathershield lug kit Catalog number 15 30 45 75 112.5 150 225 300 939 940 940 942 943 943 944 945 282B 282B 282B 282B 282B 282B 282B 282B WS57 WS58 WS58 WS59 WS60 WS60 WS61 WS62 V48M22T1516 A V48M22T3016 A V48M22T4516 A V48M22T7516 B V48M22T1216 B V48M22T4916 B V48M22T2216 V48M22T3316 LKS1 LKS1 LKS1 LKS2 LKS2 LKS3 LKS3 LKS3 A Suitable for use with wall-mounted bracket WMB05. B Suitable for use with wall-mounted bracket WMB04. Three-phase encapsulated, 480 delta—208 Y/120, 115 °C rise kVA Frame number Wiring diagram Catalog number 3 6 9 15 30 45 75 201 200 103 95 243 244 245 70A 70A 70A 72B 84A 84A 84A Y48G28T03N Y48G28T06N Y48G28T09N Y48D28T15N Y48M28T30N Y48M28T45N Y48M28T75N NNote: For frame drawings and wiring diagrams, refer to www.eaton.com/transformers. EATON www.eaton.com 23 General-purpose transformers Single-phase ventilated, 240 x 480—120/240, 150 °C rise, aluminum windings, DOE 2016 kVA Frame number Wiring diagram Weathershield Typical Catalog lug kit number 15 25 37.5 50 75 100 167 842 842 843 843 844 844 814 3XA 3XA 3XA 3XA 3XA 3XA 288A WS45 WS45 WS43 WS43 WS44 WS44 WS13 LKS1 LKS1 LKS1 LKS2 LKS2 LKS3 LKS3 T20P11S1516 A T20P11S2516 A T20P11S3716 T20P11S5016 T20P11S7516 T20P11S9916 T48P11S6716 B A Suitable for use with wall-mounted bracket WMB01. B 480 V primary only. Single-phase encapsulated 240 x 480—120/240, 115 °C rise kVA Frame number Wiring diagram Catalog number 0.05 0.075 0.1 0.15 0.25 0.5 0.75 1 1.5 2 3 5 7.5 10 15 25 37.5 52 53 54 55 57P 57P 58P 67P 67P 68P 176 177 178 179 180 182 300A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 23A 248A S20N11S81N S20N11S85N S20N11S82N S20N11S83N S20N11P26P S20N11P51P S20N11P76P S20N11P01P S20N11P16P S20N11P02P S20N11S03N S20N11S05N S20N11S07N S20N11S10N S20N11S15N S20L11S25N S20L11S37 NNote: For frame drawings and wiring diagrams, refer to www.eaton.com/transformers. 24 EATON www.eaton.com General-purpose transformers sizing tables Three-phase transformer full load current Rated line–line voltage kVA 208 240 480 600 2400 4160 4800 3 6 9 15 30 45 75 112.5 150 225 300 500 750 1000 8.3 16.7 25.0 41.6 83.3 124.9 208.2 312.3 416.4 624.6 832.7 1387.9 2081.9 2775.8 7.2 14.4 21.7 36.1 72.2 108.3 180.4 270.6 360.9 541.3 721.7 1202.8 1804.3 2405.7 3.6 7.2 10.8 18.0 36.1 54.1 90.2 135.3 180.4 270.6 360.9 601.4 902.1 1202.8 2.9 5.8 8.7 14.4 28.9 43.3 72.2 108.3 144.3 216.5 288.7 481.1 721.7 962.3 0.7 1.4 2.2 3.6 7.2 10.8 18.0 27.1 36.1 54.1 72.2 120.3 180.4 240.6 0.4 0.8 1.2 2.1 4.2 6.2 10.4 15.6 20.8 31.2 41.6 69.4 104.1 138.8 0.4 0.7 1.1 1.8 3.6 5.4 9.0 13.5 18.0 27.1 36.1 60.1 90.2 120.3 NNote: Line current = (kVA x 1000) / (line voltage x 1.732). Single-phase transformer full load current Rated line–line voltage kVA 120 208 240 277 480 600 2400 4160 4800 0.5 1 1.5 2 3 5 7.5 10 15 25 37.5 50 75 100 167 250 333 4.2 8.3 12.5 16.7 25.0 41.7 62.5 83.3 125.0 208.3 312.5 416.7 625.0 833.3 1391.7 2083.3 2775.0 2.4 4.8 7.2 9.6 14.4 24.0 36.1 48.1 72.1 120.2 180.3 240.4 360.6 480.8 802.9 1201.9 1601.0 2.1 4.2 6.3 8.3 12.5 20.8 31.3 41.7 62.5 104.2 156.3 208.3 312.5 416.7 695.8 1041.7 1387.5 1.8 3.6 5.4 7.2 10.8 18.1 27.1 36.1 54.2 90.3 135.4 180.5 270.8 361.0 602.9 902.5 1202.2 1.0 2.1 3.1 4.2 6.3 10.4 15.6 20.8 31.3 52.1 78.1 104.2 156.3 208.3 347.9 520.8 693.8 0.8 1.7 2.5 3.3 5.0 8.3 12.5 16.7 25.0 41.7 62.5 83.3 125.0 166.7 278.3 416.7 555.0 0.2 0.4 0.6 0.8 1.3 2.1 3.1 4.2 6.3 10.4 15.6 20.8 31.3 41.7 69.6 104.2 138.8 0.1 0.2 0.4 0.5 0.7 1.2 1.8 2.4 3.6 6.0 9.0 12.0 18.0 24.0 40.1 60.1 80.0 0.1 0.2 0.3 0.4 0.6 1.0 1.6 2.1 3.1 5.2 7.8 10.4 15.6 20.8 34.8 52.1 69.4 NNote: Line current = (kVA x 1000) / line voltage. EATON www.eaton.com 25 Questions to ask Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Q What type of enclosure do you need? Q What type of starter do you need? Q A A —NEMA 1 (general-duty) —NEMA 3R (rain-tight) —NEMA 12 (dust-tight) —NEMA 4X (wash-down) —NEMA non-combination —NEMA combination, non-fusible or fusible —NEMA combination, breaker —Lighting contactor What is the horsepower and voltage of the motor? (Note: this will determine the NEMA starter size) A —Horsepower: 1, 5, 10, 25 hp etc. —Motor voltage: 200, 230, 460, 575 V Q What is the control voltage for the coil? Q What size overload relay is needed? Q What additional accessories do you need? A A A —120 Vac —240 Vac —480 Vac —1–5 FLA —4–20 FLA —9–45 FLA —Cover control kits, such as HAND/OFF/AUTO selector switch or STOP/START pushbuttons —CPT kits —Fuse kits Enclosed control 26 EATON www.eaton.com Catalog numbering system—non-combination and combination NEMA enclosed starters ECN 05 1 1 A A A - R63/C SSOL rating NEMA size A =00 0–9=0–9 R63/B=1–5 FLA R63/C=4–20 FLA R63/D=9–45 FLA Coil voltage Enclosure type 1 =Type 1 2 =Type 3R 4 =Type 4X 8 =Type 12 A= 120 V B= 240 V C=480 V Disconnect fuse clip rating A= None—non-fusible B=30 A / 250 V C=30 A / 600 V D=60 A / 250 V E=60 A / 600 V Class 05= Non-combination, non-reversing 16=Combination, non-fusible or fusible, non-reversing 22=Combination, breaker, non-reversing Cover control A=None B=Start/stop pushbuttons H=HOA selector switch Starters NEMA non-combination, non-reversing starters, Type 1 NEMA size Motor voltage Magnet Maximum coil hp rating voltage SSOL range Catalog number 00 200, 230 460 200, 230 460 200, 230 460 200, 230 460 200, 230 460 1-1/2 2 3 5 3 5 7-1/2 10 10 25 1–5 1–5 1–5 1–5 4–20 4–20 4–20 4–20 9–45 9–45 ECN05A1AAA-R63/B ECN05A1AAA-R63/B ECN0501AAA-R63/B ECN0501AAA-R63/B ECN0501AAA-R63/C ECN0501AAA-R63/C ECN0511AAA-R63/C ECN0511AAA-R63/C ECN0521AAA-R63/D ECN0521AAA-R63/D 0 1 2 120 120 120 120 120 120 120 120 120 120 NEMA combination, non-reversing starters, non-fusible disconnect Type 1 NEMA size Motor voltage Magnet Maximum coil hp rating voltage SSOL range Catalog number 00 200, 230 460 200, 230 460 200, 230 460 200, 230 460 200, 230 460 1-1/2 2 3 5 3 5 7-1/2 10 10 25 1–5 1–5 1–5 1–5 4–20 4–20 4–20 4–20 9–45 9–45 ECN16A1AAA-R63/B ECN16A1AAA-R63/B ECN1601AAA-R63/B ECN1601AAA-R63/B ECN1601AAA-R63/C ECN1601AAA-R63/C ECN1611AAA-R63/C ECN1611AAA-R63/C ECN1621AAA-R63/D ECN1621AAA-R63/D 0 1 2 120 120 120 120 120 120 120 120 120 120 EATON www.eaton.com 27 Starters NEMA enclosures with CPT modifications To order an enclosure with CPT: 1. Change ECN05 to ECN07 for non-combination units, and ECN16 to ECN18 for combination units. 2. Change the “A” in the 7th catalog string to the correct letter based on the below table: Catalog string letter Primary Secondary E B C 208/60 240/480–220/440 wired for 240 V 240/480–220/440 wired for 480 V 120/60 120/60–110/50 120/60–110/50 NEMA accessories—CPT and fuse kits Description Catalog number 100 VA CPT kit (208/277 V primary, 120 V secondary) 100 VA CPT kit (240/480 V primary, 120 V secondary) Fuse clip kit for combination starter—30 A / 250 V Fuse clip kit for combination starter—30 A / 600 V and 60 A / 250 V C341CE C341CC C351KC21 C351KD22-61 NEMA accessories—cover control kits Catalog number Description STOP/START pushbuttons STOP/START pushbuttons with red RUN light (85–264 Vac) HAND/OFF/AUTO selector switch HAND/OFF/AUTO selector switch with red RUN light (85–264 Vac) 28 Noncombination Type 1, size 00–2 Noncombination Type 1, size 3–5 Combination Type 1 and all Type 3R, 12, 4X C600M1 C600M101A C400GK1 C400GK12 C400T1 — C600M12 C400GK3 C400T12 C600M121A C400GK32 — EATON www.eaton.com Catalog numbering system—enclosed lighting contactors ECL 03 C 1 A 2 A Contactor type C=C30CN L =CN35 and A202 Enclosure type 1 =Type 1 2 =Type 3R 4 =Type 4X 8 =Type 12 Class 03= Non-combination, electrically held contactors 04= Non-combination, mechanically held contactors Coil voltage A=120 V B=240 V C=480 V Amperes A=10 A B=20 A C=30 A D=60 A E=100 A Poles 2–9 = A = B = D = 2–9 poles required 10 poles required 12 poles required 20 poles required Disconnect ratings A = None Lighting contactors Lighting non-combination contactors, Type 1 Contactor type Number Ampere of poles rating Coil voltage Catalog number C30CN, electrically held C30CN, electrically held C30CN, electrically held CN35, electrically held CN35, electrically held CN35, electrically held 2 4 6 2 4 6 120 120 120 120 120 120 ECC03C1A2A ECC03C1A4A ECC03C1A6A ECL03B1A2A ECL03B1A4A ECL03B1A6A 30 30 30 20 20 20 EATON www.eaton.com 29 Questions to ask Step 1 Q Step 2 Do you need an assembled pushbutton station or loose components in clam-shell packaging? A —Assembled pushbutton station —Loose components in clam-shell package For pushbutton stations Q What size of pushbutton station do you need? Q How many elements (operators) do you want? A A —22 mm —30 mm —1 —2 —3 Step 3 For loose components Q What type of operator do you need? A —Emergency stop operator —Momentary pushbutton —Indicating light —Illuminated pushbutton —Selector switches Pushbutton stations and pushbuttons 30 EATON www.eaton.com Pushbutton stations 30 mm pushbutton stations Catalog number Description Single-element Emergency Off—break glass pushbutton station, NC Man-Off-Auto selector switch pushbutton station, 2NO Stop mushroom head pushbutton station, 1NC 10250TGR 10250T3524 10250T3519 Two-element Start-Stop pushbutton station, 1NO-2NC Start-Stop rectangular pushbutton station, 1NO-1NC 10250T3525 10250H5200 Three-element Open-Close-Stop pushbutton station, 2NO-3NC 10250T3614 Up-Down-Stop rectangular pushbutton station, 2NO-1NC 10250H5301 22 mm pushbutton stations Catalog number Description Single-element 40 mm mushroom head push-pull emergency M22-C1-M1H stop operator, NC 40 mm illuminated mushroom head push-pull emergency M22-C1-M2H stop operator, 85–264 Vac, NO-NC Two-element Flush pushbutton, Start-Stop, NO-NC Flush pushbutton, Forward-Reverse, 2NO M22-C2-M2V M22-C2-M3V Three-element Flush pushbutton, Open-Stop-Close, 2NO-1NC Flush pushbutton, Forward-Stop-Reverse, 2NO-1NC Flush pushbutton, Up-Stop-Down, 2NO-NC M22-C3-M4V M22-C3-M5V M22-C3-M6V EATON www.eaton.com 31 Pushbutton components Individually packaged 30 mm pushbuttons and operators NEMA 4, 4X, 12 13 Catalog number Description Emergency stop operator Red non-illuminated push-pull, 1NO-1NC, includes 2 legend plates: EMERG. STOP and STOP Jumbo mushroom pushbutton, 1NO-1NC, button engraved EMERG. STOP (button is engraved— no legend plate provided) Red mushroom pushbutton engraved EMERG. STOP, 1NO-1NC, includes 2 legend plates: EMERG. STOP and STOP 10250T5B62-1-POP 10250T33-POP 10250T32R-POP Momentary pushbutton Black flush pushbutton, 1NO-1NC, includes 1 legend 10250T30B-POP plate: START and JOG Red extended pushbutton, 1NO-1NC, includes 1 legend 10250T31R-POP plate: STOP Indicating light Red indicating light transformer 120 Vac with two extra 10250T34R-POP lenses (green and amber), 1NO-1NC, includes 2 legend plates: RUN and JOG Illuminated pushbutton Red illuminated pushbutton (120 Vac/Vdc),with 2 extra lenses (green and amber), 1NO-1NC, includes 1 legend plate: Power On 10250T411C21-1-POP Selector switches Two-position selector switch, 1NO-1NC, includes 3 legend plates: Off/On, Hand/Auto and Run/Jog Three-position selector switch, 2NO-2NC, includes 1 legend plate: Hand/Off/Auto Three-position selector switch, 1NO-1NC, includes 1 legend plate: Hand/Off/Auto 32 EATON www.eaton.com 10250T20KB-POP 10250T22KB-POP 10250T21KB-POP Questions to ask Step 1 Step 2 Step 3 Step 4 Q What is the motor nameplate information? Q What type of enclosure is needed? Q Is overload protection required? Q What type of operator does the customer want? A A A A —System (AC or DC) and voltage? —If AC, is the motor single-phase or three-phase? —What is the motor horsepower? —No enclosure (will be mounted in separate enclosure) —NEMA 1 enclosure —No —Yes. If yes, what is the motor full load amperes (FLA)? —Button —Toggle Manual starters EATON www.eaton.com 33 Manual starters Manual motor switches without overload Type Maximum motor (hp) Pole config. Catalog number 120 V 240 V 480 V 230 V Open B230A Two-pole 2 B230B Two-pole 2 Three-pole 3 5 5 7.5 — 10 15 — 15 20 Enclosed B230AN B230AG B230BND B230BGD B330AND B330AGD Single-phase manual starters with overload protection— Type MS series starters A Maximum motor (hp) AC voltage Pole config. Single-pole Two-pole Catalog number 120 Vac 240 Vac 277 Vac Open Enclosed B 1 1 1 1 1 1 MST01 MST02 MST01SN1P MST02SN1P Maximum motor (hp) DC voltage Pole config. Single-pole Two-pole Catalog number 120 Vdc 240 Vdc 32 Vdc Open Enclosed B ¼ ¼ ¼ ¼ ¼ ¼ MST01 MST02 MST01SN1P MST02SN1P A Use MSH heaters for MS series starters. B With pilot light. Single- and three-phase manual starters with overload protection— Type B100 A Maximum motor (hp) AC voltage Pole config. NEMA 120 size Vac Two-pole 0 (single-phase) 1 Three-pole 0 (three-phase) 1 1 2 2 3 Catalog number 208– 480– 240 Vac 600 Vac Open Enclosed B 2 3 3 7½ B100M0B B100M1B B100M0C B100M1C B100S0B B100S1B B100S0C B100S1C — — 5 10 Maximum motor (hp) Pole config. DC voltage NEMA size 115 Vdc Two-pole 0 (single-phase) 1 Three-pole 0 (three-phase) 1 1 1½ — — Catalog number 230 Vdc Open Enclosed B 1½ 2 — — B100M0B B100M1B B100M0C B100M1C B100S0B B100S1B B100S0C B100S1C A Use FH heaters for Type B100 starters. B NEMA 1. 34 EATON www.eaton.com Questions to ask Step 1 Step 2 Step 3 Step 4 Q Application? Q kA rating per phase? Q How many phases? Q System voltage? A A A A —Service entrance (contact Eaton) —Distribution panel —Control panel —50 kA —100 kA —Greater than 100 kA —Single-phase —Three-phase —See voltage codes in unit configuration tables Surge protection EATON www.eaton.com 35 Catalog numbering system—SP1 SP1 XXXX Series SP1 Voltage code 240S = 120/240 V single split-phase 208Y = 120/208 wye 480Y = 277/480 wye 600Y = 347/600Y wye 240D = 240 delta 480D = 480 delta 600D = 600 delta NNote: SP1MNTGKIT = optional wall or DIN rail mounting kit (order separately—not included with SP1 unit) Catalog numbering system—CVX CVX 050 – 240S Per phase peak surge current 050= 50 kA 100= 100 kA 36 Configuration and voltage ranges 230L =Single-phase—480 Vac 240S =Split-phase—100/200, 110/220, 120/240 Vac 240H =Three-phase high leg delta—120/240 Vac 208Y =Three-phase wye (star)—100/174, 110/190, 120/208, 127/220 Vac 480Y =Three-phase wye (star)—220/380, 230/400, 240/415, 277/480 Vac 600Y =Three-phase wye (star)—305/525, 347/600 Vac 240D =Three-phase delta—320, 208, 220, 230, 240 Vac 480D =Three-phase delta—380, 400, 415, 480 Vac 600D =Three-phase delta—525, 600 Vac 048DC=Direct current—48 Vdc 125DC=Direct current—125 Vdc EATON www.eaton.com Distribution panel surge protection Peak surge current (kA) Phase Voltage Catalog number 50 100 50 100 50 100 50 100 50 100 Single Single Three Three Three Three Three Three Three Three 120/240 120/240 208Y/120 208Y/120 240 delta 240 delta 480 delta 480 delta 480Y/277 480Y/277 CVX050-240S CVX100-240S CVX050-208Y CVX100-208Y CVX050-240D CVX100-240D CVX050-480D CVX100-480D CVX050-480Y CVX100-480Y CVX accessories Description Catalog number External mounting feet MNTGFTX Control panel surge protection Peak surge current (kA) Phase Voltage Catalog number 50 50 50 50 50 Single Three Three Three Three 120/240 208Y/120 240 delta 480 delta 480Y/277 SP1-240S SP1-208Y SP1-240D SP1-480D SP1-480Y SP1 accessories Description Catalog number Optional wall or DIN rail mounting kit SP1MNTGKIT EATON www.eaton.com 37 Product contact information Call 877-ETN-CARE (877-386-2273) Notes: _______________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ 38 EATON www.eaton.com EATON www.eaton.com 39 At Eaton, we’re energized by the challenge of powering a world that demands more. With over 100 years experience in electrical power management, we have the expertise to see beyond today. From ground­breaking products to turnkey design and engineering services, critical industries around the globe count on Eaton. We power businesses with reliable, efficient and safe electrical power management solutions. Combined with our personal service, support and bold thinking, we are answering tomorrow’s needs today. Follow the charge with Eaton. Visit eaton.com/electrical. For more information, visit Eaton.com/powrstock Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2016 Eaton All Rights Reserved Printed in USA Publication No. CA08307001E / Z18522 August 2016