2: 5: SYS19: BASE2 50: 95: 98: 100: JOB: CH62318A-0459-1 Name: 4C-379 DATE: JUL 19 2002 EDS and EDSC Single and Multi-Gang Device Bodies and EFS and EFSC Single Gang Device Bodies Both EFS and EFSC single gang body family and EDS and EDSC single and two-gang standard, two or three-gang tandem device bodies are designed for use with the DS covers listed below, and the DSD covers shown on pages 376 through 378. Time: 10:09:20 AM Operator: CP COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 4C Cl. I, Div. 1 & 2, Groups B,C,Dɍ Explosionproof Cl. II, Div. 1, Groups E,F,G Dust-Ignitionproof Cl. II, Div. 2, Groups F,G Raintight Cl. III Wet Locations NEMA 3,7BɍCD,9EFG,12 Single and two-gang standard bodies have external dead end or thru-feed conduit hubs, with integral bushings, in sizes 1⁄2⍯, 3⁄4⍯ and 1⍯. Tandem bodies have thru-feed 1⍯ hubs. Each body contains 1 internal ground screw and boss per gang and external mounting feet. Order bodies and covers separately. Single Gang Feraloy Hub Size 1⁄2⍯ 3⁄4⍯ 1⍯ Dead End Cat. # EDS171 EDS271 EDS371 Through Feed Cat. # EDSC171 EDSC271 EDSC371 Dead End Cat. # EFS171 EFS271 EFS371 Through Feed Cat. # EFSC171 EFSC271 EFSC371 Three Gang Tandem Copper-free Aluminum Hub Size 1⍯ Cat. # EDSC378 Common Cover Assemblies These covers may be used with the above bodies or as replacements for the cover portions of the control device assemblies listed on pages 374, 414, 417 & 418. Description Two Gang Feraloy Hub Size 1⁄2⍯ 3⁄4⍯ 1⍯ Dead End Cat. # EDS172 EDS272 EDS372 Through Feed Cat. # EDSC172 EDSC272 EDSC372 Diagram Cat. # With one pilot light DS455-J† With one pilot light and transformer DS476-J†-T‡ With two pilot lights DS456-J†-J† With one push button DS429§ With two push buttons DS454§ With one push button and one pilot light DS510-J†§ ɍ Subject to compliance limitations of device covers selected. Only EFS & EFSC bodies with the appropriate covers are for use in Div. 1, Group B areas. † Insert color symbol. See table on page 378. ‡ Insert symbol for transformer primary voltage. See tables on page 378. Example: DS476 with red pilot light and 440 volt transformer is DS476-J1-T4. § See marking requirements on page 377. Copyright 2002 Cooper Industries, Inc. STIBOINFO((CRH:MAIN:4C:379)) PDFINFO CH0 4 C- 1 2 379 Zoom: 100 5 Steps To make component selection simple we have developed the following five-step process. A worksheet that can be completed and used as a reference when pulling components from stock is available from the Resources area of the Cooper Crouse-Hinds website. Step 1 Select a Cover Cover only – No Device Operators or Contact Blocks Cat. # Single gang (Iron cover with single hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS441 Single gang (Iron cover with 2 holes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS442 11⁄2 gang (Aluminum cover with 3 holes, to be used with EFD1491-SA series of back boxes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS443-SA Replacement cover plug for unused device operator openings . . . . . . . . . . . . . . . . DS: 0206765 Options Suffix to be added to cat. # Aluminum cover (mandatory suffix on DS443) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA Exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752 Interior & exterior epoxy powder coat finish. Not available on three-operator cover (DS443-SA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753 Step 2 Select a Back Box DEAD END Back Box Arrangement Single gang back box Single gang back box Single gang back box Two gang back box Two gang back box Two gang back box 11⁄2 gang back box 11⁄2 gang back box 11⁄2 gang back box Hub Size 1⁄2" 3⁄4" 1" 1⁄2" 3⁄4" 1" Cat. # EDS171* EDS271* EDS371* EDS172* EDS272* EDS372* Use with Cover DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 1⁄2" 3⁄4" 1" EFD1491-SA EFD2491-SA EFD3491-SA DS443-SA DS443-SA DS443-SA Hub Size 1⁄2" 3⁄4" 1" 1⁄2" 3⁄4" 1" Cat. # EDSC171* EDSC271* EDSC371* EDSC172* EDSC272* EDSC372* Use with Cover DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 DS441 or DS442 1⁄2" 3⁄4" EFDC1491-SA EFDC2491-SA EFDC3491-SA DS443-SA DS443-SA DS443-SA THROUGH FEED Back Box Arrangement Single gang back box Single gang back box Single gang back box Two gang back box Two gang back box Two gang back box 11⁄2 gang back box 11⁄2 gang back box 11⁄2 gang back box 1" Options Suffix to be added to cat. # Aluminum body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA * Exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752 Interior & exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753 2 GET CUSTOM-BUILT CONTROL STATIONS WITH off-the-shelf turnaround times. The FlexStation offering is a complete system of interchangeable control station devices that can be quickly and easily assembled on-site into hundreds of configurations, to meet your specific application requirements. Applications FlexStation factory-sealed control stations are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled. They are used: ■ in conjunction with magnetic starters or contactors for remote control of motors ■ to prevent arcing of an enclosed device from causing ignition of hazardous atmosphere(s) outside the enclosure ■ in industrial areas where the atmosphere may contain hazardous gases and/or dusts, such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, and metal handling or finishing areas ■ in nonhazardous areas where sturdy, durable enclosures are required A COMPLETE SYSTEM OF DEPENDABLE DEVICES AND COMPONENTS ■ Device operators - Pushbuttons, including single and double maintained and momentary buttons (red/green/black) - Pilot lights in five colors with and without transformers - Selector switches including keyed and spring return to center options ■ ■ Covers - Iron or aluminum - One, two or three device holes - Cover subassemblies with various combinations of operators on a single cover Back boxes - Iron or aluminum ■ ■ ■ Contact blocks - Factory sealed Device legend plates including premarked and blank Hinged and open-front environmental control station covers The FlexStation line also includes a three-operator cover. The following combinations may be used on the three-operator cover; order by components. ■ Hinged and open-front environmental covers are available. See page 5 for ordering information. ■ Two pilot lights plus single pushbutton Triple pushbutton ■ Triple pilot light ■ Two pushbuttons plus single pilot light ■ Plus any other combination of pushbuttons, pilot lights and selector switches, limited to one contact block per device Standard Materials Standard Finishes ■ Back boxes and covers – ■ Feraloy – electrogalvanized and ® Feraloy or copper-free aluminum aluminum acrylic paint ■ Copper-free aluminum – natural ■ Device operators ■ Stainless steel – natural - guard – nylon - operator bearing – stainless steel Electrical Ratings - operating shaft – stainless steel ■ Pushbuttons – 600 VAC heavy-duty - mounting block – iron with zinc plate finish (NEMA A600) - pushbutton button – nylon ■ Pilot lights – 120 V (higher voltages - pilot light jewel – tempered glass available, see options) ■ Legend plate – aluminum ■ Contact blocks – thermoplastic with brass contacts Compliances Class I, Division 1, Groups* C, D Class I, Division 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G 1 Class III Zone 1 & 2 Groups IIB* UL/cUL Listed * For Class I, Division 1, Group B or Zone 1 Hydrogen applications, use the EFS(C) complete control station catalog numbers listed in Product Catalog. Dimensions* (inches) ONE- AND TWO-OPERATOR CONTROL STATIONS – SINGLE AND TWO GANG BACK BOX SIDE VIEW BACK BOX FRONT VIEW single gang h 11/32 15/32 1 5/16 11/32 DIM. “h” DIM. “i” 1/2 3/4 1 3/4 7/8 1 13/16 13/16 15/16 Inside Depth 2 11/16 5 3/32 X MAINTAINED MUSHROOM HEAD PUSHBUTTON — DEV11-S769 = 3 1/2 MOMENTARY MUSHROOM HEAD PUSHBUTTON — DEV11 OR DEV12 WITH SUFFIX S111 = 3 11/32 5 3/32 5 7/8 DIM. “X” PUSHBUTTON — DEV11, DEV12 = 2 11/16 two gang 1 5/16 i HUB SIZE † COVERS DOUBLE PUSHBUTTON — DEV22 = 2 13/16 (EDS) PILOT LIGHT — DEV30 = 3 11/32 SELECTOR SWITCH = 2 1/2 1 1 5/16 3 1/16 KEYED SELECTOR SWITCH: WITH KEY = 4 1/8 WITHOUT KEY = 3 1/8 5/16 2 Gang 7 3/16 3 1/2 THREE-OPERATOR CONTROL STATIONS BACK BOX SIDE VIEW h BACK BOX FRONT VIEW 11/32 15/32 HUB SIZE DIM. “h” DIM. “i” 1/2 3/4 1 3/4 7/8 1 13/16 13/16 15/16 † COVERS 1 5/16 PUSHBUTTON — DEV11, DEV12 = 2 7/32 X i Inside Depth 2 11/16 DIM. “X” 7 1/4 MAINTAINED MUSHROOM HEAD PUSHBUTTON — DEV11-S769 = 3 MOMENTARY MUSHROOM HEAD PUSHBUTTON — DEV11 OR DEV12 WITH SUFFIX S111 = 2 7/8 8 1/32 (EFD) DOUBLE PUSHBUTTON — DEV22 = 2 11/32 PILOT LIGHT — DEV30 = 2 7/8 SELECTOR SWITCH = 2 1 5/16 3 1/8 KEYED SELECTOR SWITCH: WITH KEY = 3 5/8 WITHOUT KEY = 2 5/8 3 1/2 * Dimensions are approximate, not for construction purposes. † Covers have same length and width as back boxes. Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 (315) 477-5531 FAX: (315) 477-5179 crouse.customerctr@crouse-hinds.com Cooper Electrical Australia 61-29-743-7000 FAX: 61-29-743-7069 sales@cooperelectrical.com.au In Canada: Cooper Crouse-Hinds Canada (905) 507-4187 FAX: (905) 568-7048 In Mexico: Crouse-Hinds Domex, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4078 In Latin America/Caribbean: Cooper Crouse-Hinds (954) 764-3853 FAX: (954) 764-3854 In Asia (Singapore): CEAG Crouse-Hinds Asia Pacific Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 sales@cchspore.com.sg In Middle East (Dubai): CEAG Middle East LLC 971-4-324-1519 FAX: 971-4-324-1640 For the latest in new products and services,visit our website at: www.crouse-hinds.com In Europe (Germany): CEAG Sicherheitstechnik GmbH 49-6271-81524 FAX: 49-6271-81329 Solutions.Worldwide. TM 4750-1203 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2003 Cooper Industries, Inc. Printed in U.S.A.