4C EDS and EDSC Single and Multi

advertisement
2:
5:
SYS19: BASE2
50:
95:
98:
100:
JOB: CH62318A-0459-1 Name: 4C-379
DATE: JUL 19 2002
EDS and EDSC Single and
Multi-Gang Device Bodies
and EFS and EFSC Single
Gang Device Bodies
Both EFS and EFSC single gang body family
and EDS and EDSC single and two-gang
standard, two or three-gang tandem device
bodies are designed for use with the DS
covers listed below, and the DSD covers
shown on pages 376 through 378.
Time: 10:09:20 AM Operator: CP COLOR: CMYK
TCP: 15001
Typedriver Name: TS name csm no.: 100
4C
Cl. I, Div. 1 & 2, Groups B,C,Dɍ Explosionproof
Cl. II, Div. 1, Groups E,F,G
Dust-Ignitionproof
Cl. II, Div. 2, Groups F,G
Raintight
Cl. III
Wet Locations
NEMA 3,7BɍCD,9EFG,12
Single and two-gang standard bodies have
external dead end or thru-feed conduit hubs,
with integral bushings, in sizes 1⁄2⍯, 3⁄4⍯ and 1⍯.
Tandem bodies have thru-feed 1⍯ hubs.
Each body contains 1 internal ground screw
and boss per gang and external mounting
feet.
Order bodies and covers separately.
Single Gang
Feraloy
Hub
Size
1⁄2⍯
3⁄4⍯
1⍯
Dead End
Cat. #
EDS171
EDS271
EDS371
Through Feed
Cat. #
EDSC171
EDSC271
EDSC371
Dead End
Cat. #
EFS171
EFS271
EFS371
Through Feed
Cat. #
EFSC171
EFSC271
EFSC371
Three Gang
Tandem
Copper-free
Aluminum
Hub
Size
1⍯
Cat. #
EDSC378
Common Cover Assemblies
These covers may be used with the above bodies or as replacements
for the cover portions of the control device assemblies listed on
pages 374, 414, 417 & 418.
Description
Two Gang
Feraloy
Hub
Size
1⁄2⍯
3⁄4⍯
1⍯
Dead End
Cat. #
EDS172
EDS272
EDS372
Through Feed
Cat. #
EDSC172
EDSC272
EDSC372
Diagram
Cat. #
With one pilot light
DS455-J†
With one pilot light and
transformer
DS476-J†-T‡
With two pilot lights
DS456-J†-J†
With one push button
DS429§
With two push buttons
DS454§
With one push button and
one pilot light
DS510-J†§
ɍ Subject to compliance limitations of device covers selected. Only EFS & EFSC bodies with the appropriate covers are for use in Div. 1, Group B areas.
† Insert color symbol. See table on page 378.
‡ Insert symbol for transformer primary voltage.
See tables on page 378. Example: DS476 with red pilot light and 440 volt transformer is DS476-J1-T4.
§ See marking requirements on page 377.
Copyright 2002 Cooper Industries, Inc.
STIBOINFO((CRH:MAIN:4C:379))
PDFINFO
CH0 4 C- 1 2
379
Zoom: 100
5 Steps
To make component selection simple we have developed the following five-step process.
A worksheet that can be completed and used as a reference when pulling components
from stock is available from the Resources area of the Cooper Crouse-Hinds website.
Step 1
Select a Cover
Cover only – No Device Operators or Contact Blocks
Cat. #
Single gang (Iron cover with single hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS441
Single gang (Iron cover with 2 holes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS442
11⁄2 gang (Aluminum cover with 3 holes, to be used with EFD1491-SA
series of back boxes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS443-SA
Replacement cover plug for unused device operator openings . . . . . . . . . . . . . . . . DS: 0206765
Options
Suffix to be added to cat. #
Aluminum cover (mandatory suffix on DS443) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA
Exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752
Interior & exterior epoxy powder coat finish. Not available
on three-operator cover (DS443-SA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753
Step 2
Select a Back Box
DEAD END
Back Box Arrangement
Single gang back box
Single gang back box
Single gang back box
Two gang back box
Two gang back box
Two gang back box
11⁄2 gang back box
11⁄2 gang back box
11⁄2 gang back box
Hub Size
1⁄2"
3⁄4"
1"
1⁄2"
3⁄4"
1"
Cat. #
EDS171*
EDS271*
EDS371*
EDS172*
EDS272*
EDS372*
Use with Cover
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
1⁄2"
3⁄4"
1"
EFD1491-SA
EFD2491-SA
EFD3491-SA
DS443-SA
DS443-SA
DS443-SA
Hub Size
1⁄2"
3⁄4"
1"
1⁄2"
3⁄4"
1"
Cat. #
EDSC171*
EDSC271*
EDSC371*
EDSC172*
EDSC272*
EDSC372*
Use with Cover
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
DS441 or DS442
1⁄2"
3⁄4"
EFDC1491-SA
EFDC2491-SA
EFDC3491-SA
DS443-SA
DS443-SA
DS443-SA
THROUGH FEED
Back Box Arrangement
Single gang back box
Single gang back box
Single gang back box
Two gang back box
Two gang back box
Two gang back box
11⁄2 gang back box
11⁄2 gang back box
11⁄2 gang back box
1"
Options
Suffix to be added to cat. #
Aluminum
body
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA
*
Exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752
Interior & exterior epoxy powder coat finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753
2
GET CUSTOM-BUILT CONTROL STATIONS WITH
off-the-shelf turnaround times.
The FlexStation offering is a complete system of interchangeable control
station devices that can be quickly and easily assembled on-site into
hundreds of configurations, to meet your specific application requirements.
Applications
FlexStation factory-sealed control stations are installed in a rigid metallic conduit
system for surface mounting adjacent to or remote from equipment being
controlled. They are used:
■ in conjunction with magnetic starters or contactors for remote control of motors
■ to prevent arcing of an enclosed device from causing ignition of hazardous
atmosphere(s) outside the enclosure
■ in industrial areas where the atmosphere may contain hazardous gases and/or
dusts, such as chemical plants, oil and gas refineries, paint and varnish
manufacturing plants, gasoline bulk loading terminals, grain elevators, grain
processing industries, coal processing or handling areas, and metal handling
or finishing areas
■ in nonhazardous areas where sturdy, durable enclosures are required
A COMPLETE SYSTEM OF DEPENDABLE DEVICES AND COMPONENTS
■
Device operators
- Pushbuttons, including
single and double maintained and momentary
buttons (red/green/black)
- Pilot lights in five colors
with and without
transformers
- Selector switches including keyed and spring
return to center options
■
■
Covers
- Iron or aluminum
- One, two or three
device holes
- Cover subassemblies
with various combinations of operators on a
single cover
Back boxes
- Iron or aluminum
■
■
■
Contact blocks
- Factory sealed
Device legend plates
including premarked
and blank
Hinged and open-front
environmental control
station covers
The FlexStation line also includes a three-operator cover. The following combinations
may be used on the three-operator cover; order by components.
■
Hinged and open-front environmental
covers are available. See page 5 for
ordering information.
■ Two pilot lights plus single pushbutton
Triple pushbutton
■ Triple pilot light
■ Two pushbuttons plus single pilot light
■ Plus any other combination of pushbuttons, pilot lights and selector switches,
limited to one contact block per device
Standard Materials
Standard Finishes
■ Back boxes and covers –
■ Feraloy – electrogalvanized and
®
Feraloy or copper-free aluminum
aluminum acrylic paint
■ Copper-free aluminum – natural
■ Device operators
■ Stainless steel – natural
- guard – nylon
- operator bearing – stainless steel
Electrical Ratings
- operating shaft – stainless steel
■ Pushbuttons – 600 VAC heavy-duty
- mounting block – iron with zinc plate finish
(NEMA A600)
- pushbutton button – nylon
■ Pilot lights – 120 V (higher voltages
- pilot light jewel – tempered glass
available, see options)
■ Legend plate – aluminum
■ Contact blocks – thermoplastic with brass contacts
Compliances
Class I, Division 1, Groups* C, D
Class I, Division 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
1
Class III
Zone 1 & 2 Groups IIB*
UL/cUL Listed
* For Class I, Division 1, Group B or Zone 1 Hydrogen applications, use the EFS(C) complete control station catalog numbers
listed in Product Catalog.
Dimensions* (inches)
ONE- AND TWO-OPERATOR CONTROL STATIONS – SINGLE AND TWO GANG
BACK BOX
SIDE VIEW
BACK BOX
FRONT VIEW
single gang
h
11/32
15/32
1 5/16
11/32
DIM.
“h”
DIM.
“i”
1/2
3/4
1
3/4
7/8
1
13/16
13/16
15/16
Inside
Depth
2 11/16
5 3/32
X
MAINTAINED MUSHROOM HEAD
PUSHBUTTON — DEV11-S769 = 3 1/2
MOMENTARY MUSHROOM HEAD
PUSHBUTTON — DEV11 OR DEV12
WITH SUFFIX S111 = 3 11/32
5 3/32
5 7/8
DIM. “X”
PUSHBUTTON — DEV11, DEV12 = 2 11/16
two gang
1 5/16
i
HUB
SIZE
†
COVERS
DOUBLE PUSHBUTTON — DEV22 = 2 13/16
(EDS)
PILOT LIGHT — DEV30 = 3 11/32
SELECTOR SWITCH = 2 1/2
1
1 5/16
3 1/16
KEYED SELECTOR SWITCH:
WITH KEY = 4 1/8
WITHOUT KEY = 3 1/8
5/16
2 Gang 7 3/16
3 1/2
THREE-OPERATOR CONTROL STATIONS
BACK BOX
SIDE VIEW
h
BACK BOX
FRONT VIEW 11/32
15/32
HUB
SIZE
DIM.
“h”
DIM.
“i”
1/2
3/4
1
3/4
7/8
1
13/16
13/16
15/16
†
COVERS
1 5/16
PUSHBUTTON — DEV11, DEV12 = 2 7/32
X
i
Inside
Depth
2 11/16
DIM. “X”
7 1/4
MAINTAINED MUSHROOM HEAD
PUSHBUTTON — DEV11-S769 = 3
MOMENTARY MUSHROOM HEAD
PUSHBUTTON — DEV11 OR DEV12
WITH SUFFIX S111 = 2 7/8
8 1/32
(EFD)
DOUBLE PUSHBUTTON — DEV22 = 2 11/32
PILOT LIGHT — DEV30 = 2 7/8
SELECTOR SWITCH = 2
1 5/16
3 1/8
KEYED SELECTOR SWITCH:
WITH KEY = 3 5/8
WITHOUT KEY = 2 5/8
3 1/2
* Dimensions are approximate, not for construction purposes.
† Covers have same length and width as back boxes.
Distributed by:
For more information:
If further assistance is required, please contact an authorized Cooper
Crouse-Hinds Distributor, Sales Office or Customer Service Department:
In the U.S.:
In Australia:
Cooper Crouse-Hinds
P.O. Box 4999
Syracuse, NY 13221
(315) 477-5531
FAX: (315) 477-5179
crouse.customerctr@crouse-hinds.com
Cooper Electrical Australia
61-29-743-7000
FAX: 61-29-743-7069
sales@cooperelectrical.com.au
In Canada:
Cooper Crouse-Hinds Canada
(905) 507-4187
FAX: (905) 568-7048
In Mexico:
Crouse-Hinds Domex, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4078
In Latin America/Caribbean:
Cooper Crouse-Hinds
(954) 764-3853
FAX: (954) 764-3854
In Asia (Singapore):
CEAG Crouse-Hinds Asia Pacific Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
sales@cchspore.com.sg
In Middle East (Dubai):
CEAG Middle East LLC
971-4-324-1519
FAX: 971-4-324-1640
For the latest in new products and
services,visit our website at:
www.crouse-hinds.com
In Europe (Germany):
CEAG Sicherheitstechnik GmbH
49-6271-81524
FAX: 49-6271-81329
Solutions.Worldwide.
TM
4750-1203
Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
© 2003 Cooper Industries, Inc.
Printed in U.S.A.
Download