CLASS J600 Volt Fuse Blocks - MT

advertisement
CLASS J 600 Volt Fuse Blocks
Mersen Class J fuse blocks accommodate all Class J fuses.
A choice of screw, pressure plate, box and special order stud connectors it a wide
range of stranded or solid copper or aluminum conductors. Insulators are either
molded glass-illed polycarbonate (GFPC) or phenolic with veriied dielectric strength
in excess of 2500V. 30A, 60A and the new 100A SJ fuse blocks feature a unique
adder block coniguration which can be snapped onto 1-, 2-, or 3-pole blocks to form
multi-pole segmented blocks of as many poles as desired. All fuse clips are made
of high conductivity tin-plated copper, with a choice of spring-reinforced or nonspring reinforced clips. Space saving options are now available in the 30A and 100A
conigurations which are noted in the product selection tables.
Recommended Fuse Usage:
• Class J Blocks (600V) use with AJT, A4J, HSJ
Ratings:
30A & 60A Clips
Connectors
Connectors
Connectors
Connectors
Spring Reinforced
Non-spring Reinforced
Spring Reinforced
Spring Reinforced
Spring Reinforced
30A & 60A Box
30A & 60A Box
100A Box
400A Box Side Clip
Non-spring Reinforced
Spring Reinforced 30A
Spring Reinforced
Spring Reinforced
30A Screw
Screw
100A Box Side Clip
400A Box In-line Clip
Non-spring Reinforced
Spring Reinforced 30A
Spring Reinforced
Spring Reinforced
30A Pressure Plate
Pressure Plate
200A Box Side Clip
600A Box In-line Clip
Non-spring Reinforced
Volts
: 600VAC / DC
Amps
: 30A, 60A, 100A,
: 200A, 400A, 600A
SCCR: : 200kA
H
Clip & Connector Types:
Approvals:
• All class J fuse blocks meet
the requirements of UL4248
(formerly UL512)
• UL listed Guide IZLT, File
E52283
• CSA certiied class 6225,
File 32169
H17
CLASS J 600 Volt Fuse Blocks
600 Volt, 30 & 60 Ampere Class J Fuse Blocks
Ampere
Rating
Connectors
Poles
Types
Catalog Number
Wire
Non-Spring
Spring
Range
Reinforced
Reinforced
60300J
60305SJ
Al/Cu
60301J
60306SJ
#2-14
60302J
60307SJ
60303J
60308SJ
ADDER
1
2
BOX
3
60310J
60315SJ
Cu*
60311J
60316SJ
#4-14
60312J
60317SJ
60313J
60318SJ
ADDER
1
2
30
GFPC
Insulator
SCREW
3
ADDER
60320J
60325SJ
1
PRESSURE
Cu*
60321J
60326SJ
2
PLATE
#4-14
60322J
60327SJ
60323J
60328SJ
-
60355SJ
Cu*
-
60356SJ
#4-14
-
60357SJ
-
60358SJ
60600J
60605J
Al/Cu
60601J
60606J
#2-14
60602J
60607J
60603J
60608J
-
60655J
Cu*
-
60656J
#4-14
-
60657J
-
60658J
3
ADDER
1
2
BOX
3
ADDER
1
2
60
GFPC
Insulator
BOX
3
ADDER
1
2
BOX
3
H18
1-Pole
2-Pole
Torque
In - lb
35
20
20
35
45
Note: To convert 30A “SJ” adder pole to single pole use
end barrier cat # U09372. To convert 30A or 60A standard J
adder pole to single use pole use end barrier cat # U09617.
Recommended mounting screws for all 30A and 60A fuse
blocks: 1/4” (0.250” dia).
45
*Fuses have copper box connectors and clips and are for
copper wires only. These are specifically designed with the
same coefficient of expansion as copper wire for improved heat
cycling and meet or exceed OEM “no aluminum” specifications.
Dimensions for 30A and 60A Standard
Class J Style Fuse Blocks
Dimensions for 30A Space Saving
“SJ” Style Fuse Blocks
Adder
Connector
3-Pole
Adder
1-Pole
2-Pole
3-Pole
CLASS J 600 Volt Fuse Blocks
600 Volt, 200, 400 & 600 Ampere Class J Fuse Blocks
Connectors
Ampere
Poles
Rating
1
Box
Al/Cu
61006SJ
100 (Al)
2
Side Clip
2/0-#6
61007SJ
60 (Cu)
61005SJ
61008SJ
1
2
Insulator
Torque In - lb
Wire Range
3
GFCP
Box
3
1
2
Spring Reinforced
Connector
Type
Adder
100
Catalog Number
Box
3
Al/Cu
2/0-#6
61036J
61037J
120
61038J
61006J
Cu*
2/0-#12
61007J
50
61008J
H
Dimensions for 100A Space Saving “SJ” Style Fuse Blocks
Adder
2-Pole
1-Pole
3-Pole
Dimensions for 100A Standard Class J Style Fuse Blocks
1-Pole
2-Pole
3-Pole
For the most current product performance data visit ep.mersen.com and use catalog search.
H19
CLASS J 600 Volt Fuse Blocks
600 Volt, 200, 400 & 600 Ampere Class J Fuse Blocks
Ampere
Rating
200
Phenolic
Insulator
400
Phenolic
Insulator
600
Phenolic
Insulator
Connector
Poles
Catalog No.
Spring
Fig.
Type
Wire Range
1
Box
Al/Cu
62001J
1
3
Side-Clip
350kcmil-#6
62003J
2
1
Box
Cu**
62051J
1
3
Side-Clip
350kcmil-#6
62053J
2
1
Box*
AL/Cu
64001J
3
3
Side-Clip
1000-250kcmil
64003J
4
1
Box
AL/Cu
64031J
5
3
In-Line Clip
(2) 350kcmil-#4
64033J
6
1
Box*
Cu**
64051J
3
3
Side-Clip
1000-250kcmil
64053J
4
1
Box
Cu**
64061J
5
3
In-Line Clip
(2) 350kcmil-#6
64063J
6
1
Box
Al/Cu
6631J
7
3
In-Line Clip
(2) 500kcmil-#4
6633J
8
1
Box
Cu**
6661J
7
3
In-Line Clip
(2) 500kcmil-#4
6663J
8
Reinforced
Connector
Torque In - lb
375
275
375
* Not UL Listed or CSA
Certified
275
** Fuse blocks have copper
box connectors and clips
and are for copper wires
only. These are specifically
designed with the same coefficient of expansion as copper
wire for improved heat cycling
and meet or exceed OEM “no
aluminum” specifications.
375
275
500
375
Recommended mounting
screws:
All 200A, 400A & 600A 5/16” (.313” dia.)
Dimensions
Figure 1
Figure 5
Figure 2
Figure 3
Figure 6
Figure 7
H20
Figure 4
Figure 8
MIDGET & CLASS CC
600 Volt Fuse Blocks
600 Volt midget and Class CC fuse blocks
Mersen midget fuse blocks accommodate all 30 ampere 1-1/2” x 13/32” midget fuses.
Class CC fuse blocks accommodate all 30 ampere Class CC fuses. A choice of box,
screw, or pressure-plate connectors it a wide range of stranded or solid copper wire.
Insulators are glass-illed polycarbonate (GFPC) with veriied dielectric strength in
excess of 2500V. Fuse blocks feature a unique adder block which can be snapped
onto 1-, 2- or 3-pole blocks to form multi-pole segmented blocks of as many poles as
desired. All fuse clips are made of high conductivity tin-plated copper alloy.
Recommended Fuse Usage:
Midget Fuse Block use with ATQ, ATM, A6Y-2B, A25Z-2,
TRM, OTM, A15QS-2, GFN, GGU, A60Q-2, DCT
Clip & Connector Types
30A MIDGET/CC
COPPER BOX
SCREW WITH DOUBLE
PRESSURE PLATE
PRESSURE PLATE WITH
CONNECTOR
QUICK-CONNECTS
WITH DOUBLE QUICK-
DOUBLE QUICK- CONNECTS
CONNECTS
(CLASS CC REJECTION END)
Midget Block
Volts
: 600VAC / DC
Amps : 30A Maximum
SCCR : 100kA (depending on
fuse I.R.)
: 10kA (when using quick
connect terminal)
Class CC Block
Volts
: 600VAC / DC
Amps : 30A Maximum
SCCR : 200kA
: 10kA (when using quick
connect terminal)
Temperature/lammability GFPC
insulators rated 1250C, 94V-0
lammability.
H
Ratings:
Class CC Fuse Block use with ATDR, ATMR, ATQR
Approvals:
All fuse blocks meet the
requirements of UL 4248
Midget Block
• UL recognized component
guide IZLT2, File E52283
• CSA certiied class 6225,
File 32169
Class CC Block
• UL listed, guide IZLT, File
E52283
• CSA certiied class 6225,
File 32169
H21
MIDGET & CLASS CC
600 Volt Fuse Blocks
600 Volt, 30A Midget and Class CC Fuse Blocks
Connector
Type
Catalog No.
Wire Range
Screw w/
double quick
Cu
connects at
#10-14
both ends
Poles*
Midget
Listing
Class CC
Torque
Listing
ADDER
30310
1
30311
UL Rec.
30311R
UL
2
30312
&
30312R
&
3
30313
CSA
30313R
CSA
30310R
4
30314
Pressure plate
ADDER
30320
(sems) w/
1
30321
UL Rec.
30321R
UL
2
30322
&
30322R
&
3
30323
CSA
30323R
CSA
4
30324
30324R
ADDER
30350
30350R
1
30351
UL Rec.
30351R
UL
2
30352
&
30352R
&
3
30353
CSA
30353R
CSA
4
30354
double quick
connects at
Cu
#10-14
both ends
Copper box
Cu
#6-14
In - Ib
20
30314R
30320R
20
35
30354R
Note: To convert Midget or Class CC adder pole to single pole, use end barrier #U09301.
* Available in any number of poles. Replace last digit in Catalog Number with number of poles needed.
Example: 303112 is a 12-pole screw/double QC connector Midget Fuse Block. Total width of N poles = (N x .76) + .08
inches. 12 poles = (12 x .76”) + .08” = 9.20”.
Recommended mounting screws for all Midget and Class CC fuse blocks: #8 (.164” dia.)
Dimensions
Adder
H22
1 Pole
2 Pole
3 Pole
CLASS G 480 & 600 Volt Fuse Blocks
480 & 600V Class G Fuse Blocks
Mersen Class G fuse blocks accommodate all 15, 20, 30 and 60 ampere Class G
fuses. A choice of box, screw or pressure-plate connectors it a wide range of stranded
or solid copper wire. Insulators are glass-illed polycarbonate (GFPC) with veriied
dielectric strength in excess of 2500V. Fuse blocks feature a unique adder block which
can be snapped onto 1-, 2-, or 3-pole blocks to form multi-pole segmented blocks
of as many poles as desired. All fuse clips are made of high conductivity tin-plated
copper alloy.
Features/Benefits:
• Unique integral DIN-rail adapters for 15, 20 & 30A blocks
• Unique adder-block design (all ampere ratings) for design lexibility
• Spring reinforcing standard for 60A clips
• Features high conductivity copper alloy fuse clips
Ratings:
Recommended Fuse Usage:
Volts
Class G Blocks use with AG
: 600VAC (15, 20A)
: 480VAC (30, 60A)
: 15A, 20A, 30A, 60A
SCCR: : 100kA
: 10kA (when using quick
Clip & Connector Types
connects)
15, 20, 30, 60A
15, 20, 30A
15, 20, 30A
COPPER BOX CONNECTOR OR
SCREW WITH DOUBLE QUICK-
PRESSURE PLATE WITH DOUBLE-
Temperature/Flammability:
ALUMINUM BOX
CONNECTS
QUICK CONNECTS
GFPC insulators rated 1250C RTI,
CONNECTOR
H
Amps
94V-0 lammability
Approvals:
All fuse blocks meet the
requirements of UL 4248
• UL Listed guide IZLT,
File E52283
• CSA Certiied class 6225,
File 32169
H35
CLASS G 480 & 600 Volt Fuse Blocks
600 Volt, 15 & 20 Ampere; 480 Volt 30 & 60 Ampere Class G Fuse Blocks
Ampere
Rating
Connector
Poles
Type
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
15
GFPC
Insulator
20
GFPC
Insulator
30
GFPC
Insulator
60
GFPC
Insulator
Wire Range
Screw w Double
Quick Connects at
Both Ends
Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends
Screw w Double
Quick Connects at
Both Ends
Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends
Screw w Double
Quick Connects at
Both Ends
Cu
#10-14
Cu
#10-14
Cu
#10-14
Cu
#10-14
Cu
#10-14
Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends
Cu
#10-14
Copper
Box
Cu
#6-14
Aluminum
Box
Al/Cu
#2-14
Copper
Box
Cu
#4-14
Catalog No.
Fig.
40110G
40111G
40112G
40113G
40120G
40121G
40122G
40123G
40210G
40211G
40212G
40213G
40220G
40221G
40222G
40223G
40310G
40311G
40312G
40313G
40320G
40321G
40322G
40323G
40350G
40351G
40352G
40353G
40605G
40606G
40607G
40608G
40655G
40656G
40657G
40658G
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
Torque
(In - Lbs)
20
20
20
20
20
20
35
45
45
Dimensions
.17x.10 DP
.17x.10 DP
3.05
1.53
.17
.34
1.45
3.78
1.89
.25
.77
1.11
1.62
1.88
2.39
.16
.76
1.40
.64
Figure 1
H36
.85
Figure 2
Figure 3
Figure 4
.35
.26
.86
1.11
1.62
1.87
2.38
.52
Figure 5
Figure 6 Figure 7
Figure 8
NH DIMENSION Fuse Bases
690V Ceramic fuse bases for NH fuses
• Ceramic insulating bases
• Silver plated contacts
• High spring contact pressure
• Screw mounting
Single-Pole Fuse Bases
Size
Rated
Current (A)
Discontinued
Catalog No.
New Ref.
No.
New Catalog
No.
Std.
Pack
00-E
160
40002-G
Z217211
BB001E
12
00-EB
160
40003-G
E217722
EB001
12
0-E
160
40004-G
P218237
BB01E
4
0-P
160
40006-G
C218755
BB01P
4
1-P
250
40008-G
R219274
BB11P
3
2-P
400
40010-G
S219804
BB21P
3
3-P
630
40012-G
D222482
BB31P
3
Ratings:
4-P
1250
40014-G
W223004
BB41P
1
Volts
: 690VAC
Amps
: 160-1250A
Rated
Current (A)
Discontinued
Catalog No.
New Ref.
No.
New Catalog
No.
Std.
Pack
00-E
160
40502-G
D201851
BB003E
3
00-EB
160
40503-G
A211071
BB003EB
3
0-E
160
40504-G
Q211591
BB03E
1
1-P
250
40508-G
T213641
BB13P
1
2-P
400
40510-G
Y214151
BB23P
1
3-P
630
40512-G
B214660
BB33P
1
Notes:
H
BB01P
Three-Pole Fuse Bases
Size
BB001E
BB23P
Size 1 fuse base will accept size 0 fuses.
Size 2 fuse base will accept size 1 fuses.
Size 3 fuse base will accept size 1 & 2 fuses.
Size 4 has a special nut to assure contact pressure.
Type E has square contacts.
Type P has pincer contacts.
Type EB has pressure-plate cable connection.
Approvals:
Designed to meet standards:
• IEC 60269-2
• DIN, VDE 0636
Insulating Barriers for Ceramic NH Fuse Bases
Size
Rated
Current (A)
Discontinued
Catalog No.
New Ref.
No.
New Catalog
No.
• DIN 43620
• NFC 63210, 63211, 60200
Std.
Pack
Friction Fit
00
100
45102-G
A201365
NH00CERAMWALLP
10
0
160
45104-G
M201882
NH0CERAMWALLP
10
1-2
400
45110-G
K211103
NH12CERAMWALLP
4
3
630
45112-G
Z211622
NH3CERAMWALLP
2
Friction Fit
NH12CERAMWALLP
Tab Fastened
00
100
45202-G
G214182
NH00CERAMWALLE
10
0
160
45204-G
L214692
NH0CERAMWALLE
10
1-2
400
45210-G
Q215202
NH12CERAMWALLE
4
Tab Fastened
NH3CERAMWALLE
3
630
45212-G
S215710
NH3CERAMWALLE
2
4
1250
45214-G
Y216221
NH4CERAMWALLE
2
H55
NH DIMENSION Fuse Bases
Dimensions of Ceramic Fuse Bases for NH Fuses
00-E, EB
0-E
0-P
1-P
2-P
3-P
4-P
33
32
32
55
55
55
80
B
20
20
25
32
35
40
45
C
118.5
269
166
210
227
241
312
D
100
151
150
175
200
210
262
E*
8
8.5
8.5
11
11
11
11
F
-
-
-
30
30
30
45
G
14.5
14
14
22
22
22
-
H
25
25
25
25
25
25
30
I
145
185
185
250
250
250
-
J
21.5
29
29
35
35
35
45
16
A
K
8
8
8
10
10
12
L
55
72
74
84
84
84
111
M
52.5
60
60
71
89
103
145
N
80
85
85
100
100
127
-
O
84
120
120
148
148
148
192
P
34
47
47
62
69
82
-
Q
1
2
2
2
2
2
-
R
101
126
126
177
190
213
-
* 8mm for all multiple pole bases; dimensions in chart for single pole bases.
H56
NH DIMENSION Fuse Bases
690V plastic fuse bases for NH fuses
• Polyester insulating bases
• Silver plated contacts
• High pressure spring contacts
• Screw or rail mount
Type 00-EP* – Fuse Bases for NH-00 Fuses without striker
Screw Connector
Rail Mt.
Poles
Discontinued
Catalog No.
New Ref.
No.
New Catalog
No.
Catalog
No.
New Ref.
No.
New Catalog
No.
Std.
Pack
1
41002-G
F215170
BB001EP
42002-G
R216192
BB001EPR
3
2
41012-G
A217212
BB002EP
42012-G
F218758
BB002EPR
2
3
41016-G
W229122
BB003EPVBLOC
42016-G
V229121
BB003EPRBLOC
1
4
41019-G
S219275
BB004EP
42019-G
Z223007
BB004EPR
1
Pressure Plate Connector
Screw Mt.
New Ref.
No.
Rail Mt.
Poles
Discontinued
Catalog No.
New Catalog
No.
Catalog
No.
New Ref.
No.
New Catalog
No.
1
41102-G
T219805
BB00EPBT
42102-G
F200795
BB001EPBR
3
2
41112-G
D200793
BB002EPB
42112-G
T211594
BB002EPBR
2
3
41114-G
W201338
BB003EPB
42114-G
C212108
BB003EPBR
1
4
41119-G
R211592
BB004EPB
42119-G
M215682
BB004EPBR
1
Ratings:
Volts
: 690VAC
Amps
: 160 to 1250A
Std.
Pack
H
Screw Mt.
* EP bases have square contacts.
Connection Detail
Approvals:
Designed to meet standards:
BB001EP
Screw
Clamp
• IEC 60269
• DIN VDE 0636-21 & 201
• DIN 43620
Dimensions
00-EP
00-EP
A
32
J
21.5
B
20
K
8
C
117
L
56
D
100
M
52
E
8
N
85
F
2
0
84
G
14
P
34
H
25
Q
1
I
145
R
104
H57
NH DIMENSION Fuse Bases
Type 0-EP* – Fuse Bases for NH-0 Fuses without striker
BB01EPR
BB12PP
BB23PP
Mounting Style
Screw
DIN-Rail
Poles
Discontinued Cat. No.
New Reference No.
New Catalog No.
Discontinued Cat. No.
New Reference No.
New Catalog No.
1
41202-G
B213142
BB01EP
42202-G
S216193
BB01EPR
2
41212-G
C214661
BB02EP
42212-G
P216696
BB02EPR
3
41214-G
G215171
BB03EP
42214-G
C217214
BB03EPR
4
41219-G
Q216191
BB04EP
42219-G
J217726
BB04EPR
* EP bases have square contacts. PP bases have pincer contacts.
Type 0-PP – Fuse Bases for NH-0 Fuses w/o striker
Poles
Discontinued Cat. No.
New Reference No.
New Catalog No.
Discontinued Cat. No.
New Reference No.
New Catalog No.
1
41302-G
N216695
BB01PP
42302-G
T218241
BB01PPR
2
41312-G
B217213
BB02PP
42312-G
G218759
BB02PPR
3
41314-G
G217724
BB03PP
42314-G
W219278
BB03PPR
4
41319-G
R218239
BB04PP
42319-G
H222486
BB04PPR
Type 1-PP – Fuse Bases for NH-1 Fuses w/o striker
Poles
Discontinued Cat. No.
New Reference No.
New Catalog No.
Discontinued Cat. No.
New Reference No.
New Catalog No.
1
41402-G
E218757
BB11PP
42402-G
A223008
BB11PPR
2
41412-G
F222484
BB12PP
42412-G
G200796
BB12PPR
3
41414-G
Y223006
BB13PP
42414-G
Y201340
BB13PPR
4
41419-G
X201339
BB14PP
42419-G
H201855
BB14PPR
Type 2-PP – Fuse Bases for NH-2 Fuses w/o striker
Poles
Discontinued Cat. No.
New Reference No.
New Catalog No.
Discontinued Cat. No.
New Reference No.
New Catalog No.
1
41502-G
F201853
BB21PP
42502-G
E211075
BB21PPR
2
41512-G
S211593
BB22PP
42512-G
V211595
BB22PPR
3
41514-G
B212107
BB23PP
42514-G
D212109
BB23PPR
4
41519-G
C213143
BB24PP
42519-G
R212627
BB24PPR
Type 3-PP – Fuse Bases for NH-3 Fuses w/o striker
Poles
Discontinued Cat. No.
New Reference No.
New Catalog No.
Discontinued Cat. No.
New Reference No.
New Catalog No.
1
41602-G
W213643
BB31PP
42602-G
X213644
BB31PPR
2
41612-G
D214662
BB32PP
42612-G
B214154
BB32PPR
3
41614-G
H215172
BB33PP
42614-G
F214664
BB33PPR
4
41619-G
L215681
BB34PP
42619-G
K215174
BB34PPR
Dimensions of Polyester Fuse Bases for NH Fuses
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
H58
0-EP
46
20
168
150.5
7.5
14.5
25
185
29
M8
74
59
95
122
48.5
94
142
190
O-PP
46
25
168
150.5
7.5
14.5
25
185
29
M8
75
61
95
122
48.5
94
142
190
1-PP
60
32
209
176
10.5
30
20.5
25
250
35
M10
81
71
122.5
146
65.5
125.5
191
256.5
2-PP
60
35
225
201
10.5
30
20.5
25
250
35
M10
81
89
122.5
146
65.5
125.5
191
256.5
3-PP
60
40
241
210
10.5
30
20.5
25
270
35
M12
81
103
142.5
146
81.5
141.5
223
304.5
NH DIMENSION Fuse Bases
Insulating Barriers for Plastic NH Fuse Bases
Size
Rated
Current (A)
Discontinued
Catalog No.
New Ref.
No.
New Cat.
No.
Std.
Pack
00
100
44502-G
W212654
BB00CL
2
0
160
44504-G
Z213669
BB0CL
2
1-2
400
44510-G
J214690
BB1-2PPCL
2
3
630
44512-G
Q215708
BB3PPCL
2
BB00CL
BB1-2PPCL
*Not for use with W229122 and V229121. Use B233865.
Separators
Size
Rated
Current (A)
Discontinued
Catalog No.
New Ref.
No.
New Cat.
No.
Std.
Pack
0
160
44604-G
V216724
BBPAK0
2
1-2
400
44610-G
N217753
BBPAK1-2
2
BBT0TS
BBPAK1-2
Fuse Shields
Size
Rated Current (A)
Discontinued Catalog No.
New Ref. No.
New Cat. No.
Std. Pack
00
100
44802-G
G213170
BB00COV
3
0
160
44804-G
F214181
BB0COV
3
1-2
400
44810-G
K214691
BB1-2COV
3
3
630
44812-G
R215709
BB3COV
2
BB00COV
Size
Rated Current (A)
Discontinued Catalog No.
New Ref. No.
New Cat. No.
Std. Pack
00
100
44702-G
M222513
BB00TS
6
0
160
44704-G
K200822
BB0TS
6
1-2
400
44710-G
Y211621
BB2TS
6
Discontinued Catalog No.
New Ref. No.
New Cat.
No.
Std.
Pack
H
Terminal Shields
One Cable – Terminal for NH Bases
Cable Size (mm)
Base
Size
Max.
Min.
00
50
6
45421-G
Q217755
BORNEABF50
60
00-0
95
10
45423-G
A218270
BORNEABF95
50
1
150
16
45425-G
N218788
BORNEABF150
30
2-3
240
50
45427-G
A219305
BORNEABF240
15
BORNEABF150
Two Cable – Terminal for NH Bases
Base
Size
Cable 1 (Size mm)
Cable 2 (Size mm)
Max.
Min.
Max.
Min.
Discontinued
Catalog No.
New Ref.
No.
New Cat.
No.
Std.
Pack
00
50
6
50
6
45431-G
B219835
BORNEABF50D
60
00-0
95
10
95
10
45433-G
P222515
BORNEABF95D
30
1
150
25
150
16
45435-G
F223036
BORNEABF150D
20
2-3
240
95
240
50
45437-G
B201366
BORNEABF240D
5
Dimensions of Terminals
Discontinued Catalog No.
New Cat. No.
A
B
C
M
45421-G
BORNEABF50
18
26
34
6
45423-G
BORNEABF95
24
35
52
8
45425-G
BORNEABF150
26
41
58
10
45427-G
BORNEABF240
36
53
68
12
45431-G
BORNEABF50D
18
26
39
6
45433-G
BORNEABF95D
24
35
82
8
45435-G
BORNEABF150D
26
41
84
10
45437-G
BORNEABF240D
36
53
98
12
For the most current product performance data visit ep.mersen.com and use catalog search.
BORNEABF150D
H59
HPBB 1000V DC Size NH Open Style Fuse Blocks
Mersen size NH fuse blocks for use with HP10NH
HelioProtection® Photovoltaic series fuses
1000VDC rated and designed speciically for Mersen’s HP10NH series of
photovoltaic fuses. These polyester fuse blocks are available in single pole
conigurations with or without inger-safe covers. Fuse blocks come standard with
M10 stud connectors for ease of wire termination. All fuse clips are silver-plated
copper and fuse clips are spring re-enforced for superior conductivity. Select
Mersen’s brand of innovative HelioProtection® products to meet your stringent
photovoltaic application requirements.
Features:
Applications:
• 1000VDC rated
• Re-combiner box (sub-combiner,
• Polyester insulating base
array combiner, master combiner)
• Silver plated contacts
applications
• M10 stud wire terminals
• Inverter DC input
Ratings:
• Optional inger-safe covers
• Battery charge controllers
Volts
: 1000VDC
Amps
: 315A max
SCCR
: 50kA
• DIN-rail or screw mounting
Recommended Fuse Usage:
• Mersen HP10NH series HelioProtection Photovoltaic Fuses
Catalog Numbers - Fuse Block
Catalog
Reference
No. of
Number
Number
Poles
HPBB11PPR
A1030607
HPBB11PPRFS
K1032916
HPBB21PPR
C1037509
HPBB21PPRFS
D1037510
For
use
Description
with
1
NH1
1
NH2
Open Style
Open Style with Protective Cover
Open Style
Approvals:
Open Style with Protective Cover
• IEC 60269-2-1 Certiication
Dimensions (mm)
• Pending: UL Listed to Standard
4248-18, File E347822
*
H60
Size
NH1
NH2
A
32
35
B
176
201
*87mm for base with protective cover
C
209
225
M10 torque recommendation: 230 in-lbs (26 Nm)
D
80
89
DFC SERIES Dead-Front Fuse Covers
Mersen DFC dead-front fuse covers snap on to individual fuses installed in fuse
blocks, covering exposed live clips and terminals and reducing accidental contact by
personnel. They are sized to it Class G, H, J, K, R, CC or midget fuses for increased
safety and (optional) open-fuse indication. All DFC dead-front fuse covers are
reusable when a fuse is replaced – simply detach from the open fuse and re-attach to
the new replacement fuse. On indicator models an orange indicator light will illuminate
to indicate an open fuse. DFC fuse cover ends can be easily cut to accommodate
existing wiring, safety switches or special installations. A blank label is provided with
each DFC to write in circuit or fuse information.
Features/Benefits:
• Innovative design provides dead-front electrical safety to personnel
• Optional orange indicator light shows open fuse
• Many sizes to it virtually all popular fuses/fuse blocks
• Reusable with no changes or additional cost
Ratings:
• Labels provided for write-in identiication
• Low leakage current <0.6 mA at 600V
Nonindicating
indicating
Volts
Amps
: Fits fuses rated 0 to
Indicating
Fuses Accomodated
Amps
: 0 to 600VAC / DC
200A
Catalog Numbers & Dimensions
Catalog Numbers
Volts
Dimensions (inches)
Class
A
B
Volts
: 90 to 600VAC
: 115 to 600VDC
C
Amps
: Fits fuses rated 0 to
DFC-1
DFC-1I
0-30
600
J
4.68
1.36
1.97
DFC-2
DFC-2I
0-30
600
R, K, H
7.45
1.35
1.80
DFC-3
DFC-3I
65-100
600
J
7.57
1.30
2.20
DFC-4
DFC-4I
65-100
250
R, K, H
8.73
1.40
2.02
DFC-5
DFC-5I
35-60
600
R, K, H
7.46
1.35
2.00
DFC-6
DFC-6I
35-60
600
J
4.64
1.40
2.17
Approvals:
DFC-7
DFC-7I
0-30
600
Midget, CC, G
3.71
0.69
1.37
DFC-8
DFC-8I
65-100
600
R, K, H
10.55
1.55
2.26
• UL Listed (All except midget
DFC-9
DFC-9I
0-30
250
R, K, H
3.71
0.85
1.55
DFC-10
DFC-10I
0-30
600
SJ
4.56
1.06
2.02
DFC-11
DFC-11I
65-100
600
SJ
5.52
1.7
2.04
DFC-12
DFC-12I
110-200
600
J
6.63
3.03
2.86
DFC-13
DFC-13I
35-60
250
R, K, H
5.20
1.12
1.92
WARNING: To avoid electrical shock, TURN POWER OFF before installing, removing or servicing.
H
Non-Indicating
• Thermoplastic lammability rating of UL 94-V2
200A
size) guide JDVS, File E90426
• UL Recognized Component
(midget) guide JDVS2, File
E90426
• CSA Certiied class 6228, File
70159
H61
DFC SERIES Dead-Front Fuse Covers
Fuses and Fuse Blocks for use with DFC
Fuse
Fuse Block
AG(0-30)
Fuse
Fuse Block
40xxxG
-7I, -7
DFC
A6K(35-60)R
606xxR
DFC
AJT(1-30)
603xxJ
-1I, -1
A6K(70-100)R
610xxR
-8I, -8
AJT(1-30)
603xxSJ
10I, -10
A6Y(0-30)-2B
303xx
-7I, -7
AJT(35-60)
606xxJ
-6I, -6
A60Q(0-30)-2
303xx
-7I, -7
AJT(70-100)
610xxJ
-3I, -3
A60X(0-30)-1
603xx
-1I, -1
AJT(70-100)
6100xxSJ
-11I, -11
A70P(10-30)-1
203xx
-9I, -9
AJT(110-200)
620xxJ
-12I, -12
GFN(0-30)
303xx
-7I, -7
ATDR(0-30)
303xxR
-7I, -7
GGU(0-30)
303xx
-7I, -7
ATM(0-30)
303xx
-7I, -7
HSJ(15-30)
603xxSJ
-10I, -10
ATMR(0-30)
303xxR
-7I, -7
HSJ(70-100)
6100xxSJ
-11I, -11
ATQ(0-30)
303xx
-7I, -7
HSJ(110-200)
620xxJ
-12I, -12
ATQR(0-30)
303xxR
-7I, -7
OT(0-30)
203xx
-9I, -9
A13X(1-30)-2
303xx
-7I, -7
OT(35-60)
206xx
-13I, -13
A2D(0-30)R
203xxR
-9I, -9
OT(65-100)
210xx
-4I, -4
A2D(35-60)R
206xxR
-13I, -13
OTM(0-30)
303xx
-7I, -7
A2D(65-100)R
210xxR
-4I, -4
OTS(0-30)
603xx
-2I, -2
A2K(0-30)R
203xxR
-9I, -9
OTS(35-60)
606xx
-5I, -5
A2K(35-60)R
206xxR
-13I, -13
OTS(65-100)
610xx
-8I, -8
A2K(70-100)R
210xxR
-4I, -4
RF(0-30)
203xx
-9I, -9
A2Y(0-30)
203xx
-9I, -9
RF(35-60)
206xx
-13I, -13
A2Y(35-60)
206xx
-13I, -13
RF(65-100)
210xx
-4I, -4
A2Y(70-100)
210xx
-4I, -4
RFS(0-30)
603xx
-2I, -2
A25X(1-30)-1
203xx
-9I, -9
RFS(35-60)
606xx
-5I, -5
-5I, -5
A25Z(1-30)-2
303xx
-7I, -7
RFS(65-100)
610xx
-8I, -8
A4J(1-30)
603xxJ
-1I, -1
TR(0-30)R
203xx
-9I, -9
A4J(1-30)
603xxSJ
-10I, -10
TR(35-60)R
206xx
-13I, -13
A4J(35-60)
606xxJ
-6I, -6
TR(70-100)R
210xx
-4I, -4
A4J(70-100)
610xxJ
-3I, -3
TRM(0-30)
303xx
-7I, -7
A4J(70-100)
6100xxSJ
-11I, -11
TRS(0-30)R
603xxR
-2I, -2
A4J(110-200)
620xxJ
-12I, -12
TRS(35-60)R
606xxR
-5I, -5
A50P(10-30)
203xx
-9I, -9
TRS(65-100)R
610xxR
-8I, -8
A6D(0-30)R
603xxR
-2I, -2
TRS(35-60)RDC
606xxR
-5I, -5
A6D(35-60)R
606xxR
-5I, -5
TRS(70-100)RDC
610xxR
-8I, -8
A6D(70-100)R
610xxR
-8I, -8
A6K(0-30)R
603xxR
-2I, -2
Note: DFC Covers fit single pole blocks and each pole of multi-pole blocks. Consult factory for data
sheets of DFC trim instructions for safety switches.
WARNING: To avoid electrical shock, TURN POWER OFF before installing, removing or servicing.
H62
DFC3M/DFC3LP/DRM
Fuse Block Accessories
DFC3M safety puller protects personnel, covers live parts
The DFC3M safety puller is intended to hold and safely enclose 1-1/2” x 13/32” midget
or Class CC fuses for insertion or removal from fuse clips, making fuse installation
easy and safe without the use of a standard fuse puller. The DFC3M is made of clear
polycarbonate, so the fuse can be identiied when installed in a 303 series fuse block.
DFC3LP safety puller holds fuse, protects personnel, and
saves space
The DFC3LP holds and safely encloses 1-1/2” x 13/32” midget or class CC fuse,
similar to the DFC3M, but with a lower proile in height so it takes less room where
space is restricted. The DFC3LP is made of clear polycarbonate so the fuse can be
seen after installation in a fuse block such as the Mersen 303 series.
DRM adapts 303 series midget and class CC fuse blocks to
DIN-rail
and class CC fuse blocks to all symmetrical 35mm DIN or asymmetrical 32mm “G”
rail. A DRM adapter is attached to each pole with the screw provided. The DRM is
H
The DIN-rail adapter, DRM, provides quick mounting for all Mersen 303 series midget
molded of black polycarbonate and is mounted or dismounted from the rail simply by
depressing the inger pull.
H63
Download