Installation Instructions CENTERLINE Motor Control Centers External Auxiliary Contact Kit for 0.5 Space Factor Circuit Breaker Units Catalog Numbers 2100H-N18A, 2100H-N18B Topic Additional Resources Page Additional Resources 1 About The Auxiliary Contact Adapter 2 Required Tools 2 Install the Auxiliary Contact Adapter 2 These documents contain additional information concerning related products from Rockwell Automation. Resource Description CENTERLINE 2100 Motor Control Centers, publication 2100-IN012 Provides General Instructions for CENTERLINE® 2100 MCC Units. Product Certifications website, http://www.ab.com Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation® sales representative. CENTERLINE Motor Control Centers External Auxiliary Contact Kit for 0.5 Space Factor Circuit Breaker Units About The Auxiliary Contact Adapter Kits 2100H-N18A and 2100H-N18B contain parts to install external auxiliary contacts in units that are the following: • 0.5 space factor. • Have one of the following Cutler-Hammer Westinghouse circuit breakers(1): GCH, GHC, GMCP, HMCP, FD, FDB, FDB-LFD, FDC, HFD, HMCP250, JD, JDC, HJD. • Bulletin 2100 Series P…Y. ATTENTION: De-energize all power sources before installing auxiliary contact. Failure to de-energize all power sources can result in severe injury or death. Required Tools You need a Phillips head screwdriver and a flat head screwdriver to complete the installation. Install the Auxiliary Contact Adapter Follow these steps and refer to Assembly of External Auxiliary Contact Parts to install the auxiliary contact adapter. TIP These external auxiliary contacts are actuated by the unit operating handle only, and will not reflect a circuit breaker trip 1. Remove the unit from the section before attempting to install the auxiliary contacts. For instructions on removing the unit, refer to Installing Units With Horizontal Operating Handles, publication 2100-IN060, and reverse the order of the steps. 2. Verify the parts list, see Assembly of External Auxiliary Contact Parts. 3. Attach the external auxiliary contact assembly to the handle mounting plate using two #8-32 x 0.38 thread forming screw. 4. Torque to 20 lb•in (2.2 N•m). 5. Turn the operator handle to the ON/I position to ensure that the auxiliary contacts change state. 6. Check continuity to ensure proper operation of the auxiliary contacts. (1) These circuit breakers are available for Bulletin 2100 Series Y and earlier motor control centers. 2 Rockwell Automation Publication 2100-IN001C-EN-P - April 2014 CENTERLINE Motor Control Centers External Auxiliary Contact Kit for 0.5 Space Factor Circuit Breaker Units Figure 1 - Assembly of External Auxiliary Contact Parts Auxiliary Contact Assembly Parts List (1) Auxiliary Contact Assembly (1) Actuator Arm (3) #8-32 x 0.38 screw #8-32 x 0.38 screw Actuator Arm Mounting Location ‘G’ Circuit Breakers Mounting Location ‘F’, ‘J’ Circuit Breakers Handle Mounting Plate Handle Operator Link Note: Unit mounting plate and devices have been omitted in this drawing for clarity. Rockwell Automation Publication 2100-IN001C-EN-P - April 2014 3 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support you can find technical and application notes, sample code, and links to software service packs. You can also visit our Support Center at https://rockwellautomation.custhelp.com/ for software updates, support chats and forums, technical information, FAQs, and to sign up for product notification updates. In addition, we offer multiple support programs for installation, configuration, and troubleshooting. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/services/online-phone. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/rockwellautomation/support/overview.page, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Software, Rockwell Automation, and CENTERLINE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 2100-IN001C-EN-P - April 2014 Supersedes Publication 2100-IN001B-EN-P - March 2014 Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.