600G-FL - Itron Commercial Meters(AMIG-221)

advertisement
AMIG-221
SmartPoint™
Actaris Adapter Mounting Instructions
Adapting Actaris Large Diaphragm Top Mount Gas Meters to 600G-FL SmartPoint Transmitter
APPLICABLE M E T E RS
4. Clear any debris from the top surface of the meter
index plate.
Actaris A-Series Meters: 675A, 800A, 1000A
COMPONENT S
Verify all the required components for the installation
are available:
I N STA L L S M A RT P O I N T O N M E T ER
1. Place one (1) of the white plastic clearance spacers
in each of the four (4) mounting holes on the
underside of the 600G-FL SmartPoint.
80 0G-FL ADA P T E R P L AT E K I T
• 600G-FL SmartPoint transmitter
• Adapter Plate
• 4x long Phillips head screws
• 4x white plastic clearance spacers
• 2x short Phillips head screws
• 2x red tamper seals
• 1x wriggler extension
TOOLS
• Flat blade screwdriver (1/4” blade)
• #3 Phillips screwdriver
• ¼” Nut driver
2. Position the 600G-FL SmartPoint on the top of the
meter. Be sure the Sensus logo is facing the front
of the meter and the shaft is aligned properly.
REMOVING I N D E X A N D C OV E R
1. Remove and properly dispose of the red tamper
seals, if present.
2. Remove and dispose of the four (4) index
cover attachment screws using the flat blade
screwdriver. Set aside the index cover for
reinstallation.
3. Remove the two (2) mechanical index attachment
screws using the flat blade screw driver. Set index
aside for reinstallation.
WARNING: Substitution of components may impair suitability for Class I Division 2.
AVERTISSEMENT: Risque d’explosion - la substitution de composants peut rendre
ce matériel inacceptable pour les emplacements de Classe I, Division 2.
Page 1 of 2
AMIG-221
3. Position and press-fit the wriggler extension onto
the SmartPoint transmitter shaft.
6. Place the Actaris index cover on top of the adaptor
plate. Drop the four (4) long Phillips head screws
through the index cover holes. Carefully place this
assembly on top of the meter.
4. Lay the adapter plate on a flat surface. Mount the
mechanical index to the adapter plate with the
two short Phillips head screws. Tighten the screws
to 20-25 in-lbs of torque. Be sure the dials and
Sensus logo face the front.
7. Tighten the screws in a cross pattern to reach 3035 in-lbs of torque using the Philips screwdriver.
5. Position the adapter plate assembly on top of the
SmartPoint transmitter. Be sure the index drive
dog fits into the slots of the wriggler extension.
This is critical for proper operation of the
mechanical index.
8. Install the two red tamper seals fully with the
aid of the ¼” nut driver. Align the end of the nut
driver on the seal and tap the end of the nut driver
handle until the seal is fully seated.
P RO G R A M M I N G S M A RT P O I N T
T R A N S M I TT E R
Refer to AMIG-301 for programming instructions.
Page 2 of 2
AUTHORIZED SENSUS DISTRIBUTOR
805 Liberty Boulevard
DuBois, PA 15801 USA
T: 1-800-375-8875
F: 1-814-375-8460