AMIG-221 SmartPoint™ Actaris Adapter Mounting Instructions Adapting Actaris Large Diaphragm Top Mount Gas Meters to 600G-FL SmartPoint Transmitter APPLICABLE M E T E RS 4. Clear any debris from the top surface of the meter index plate. Actaris A-Series Meters: 675A, 800A, 1000A COMPONENT S Verify all the required components for the installation are available: I N STA L L S M A RT P O I N T O N M E T ER 1. Place one (1) of the white plastic clearance spacers in each of the four (4) mounting holes on the underside of the 600G-FL SmartPoint. 80 0G-FL ADA P T E R P L AT E K I T • 600G-FL SmartPoint transmitter • Adapter Plate • 4x long Phillips head screws • 4x white plastic clearance spacers • 2x short Phillips head screws • 2x red tamper seals • 1x wriggler extension TOOLS • Flat blade screwdriver (1/4” blade) • #3 Phillips screwdriver • ¼” Nut driver 2. Position the 600G-FL SmartPoint on the top of the meter. Be sure the Sensus logo is facing the front of the meter and the shaft is aligned properly. REMOVING I N D E X A N D C OV E R 1. Remove and properly dispose of the red tamper seals, if present. 2. Remove and dispose of the four (4) index cover attachment screws using the flat blade screwdriver. Set aside the index cover for reinstallation. 3. Remove the two (2) mechanical index attachment screws using the flat blade screw driver. Set index aside for reinstallation. WARNING: Substitution of components may impair suitability for Class I Division 2. AVERTISSEMENT: Risque d’explosion - la substitution de composants peut rendre ce matériel inacceptable pour les emplacements de Classe I, Division 2. Page 1 of 2 AMIG-221 3. Position and press-fit the wriggler extension onto the SmartPoint transmitter shaft. 6. Place the Actaris index cover on top of the adaptor plate. Drop the four (4) long Phillips head screws through the index cover holes. Carefully place this assembly on top of the meter. 4. Lay the adapter plate on a flat surface. Mount the mechanical index to the adapter plate with the two short Phillips head screws. Tighten the screws to 20-25 in-lbs of torque. Be sure the dials and Sensus logo face the front. 7. Tighten the screws in a cross pattern to reach 3035 in-lbs of torque using the Philips screwdriver. 5. Position the adapter plate assembly on top of the SmartPoint transmitter. Be sure the index drive dog fits into the slots of the wriggler extension. This is critical for proper operation of the mechanical index. 8. Install the two red tamper seals fully with the aid of the ¼” nut driver. Align the end of the nut driver on the seal and tap the end of the nut driver handle until the seal is fully seated. P RO G R A M M I N G S M A RT P O I N T T R A N S M I TT E R Refer to AMIG-301 for programming instructions. Page 2 of 2 AUTHORIZED SENSUS DISTRIBUTOR 805 Liberty Boulevard DuBois, PA 15801 USA T: 1-800-375-8875 F: 1-814-375-8460 www.sensus.com/gas