Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Acute Sales Limited Issue No: 012 0811 Accredited to ISO/IEC 17025:2005 Issue date: 10 May 2016 Century Road Contact: James Chinnock High Carr Business Park Tel: +44 (0)1782 563030 Ext 204 Newcastle-under-Lyme Fax: +44 (0)1782 563131 Staffordshire E-Mail: James.Chinnock@acutesales.co.uk ST5 7UG Website: www.acutest.net Calibration performed at the above address only DETAIL OF ACCREDITATION Measured Quantity Instrument or Gauge Range Calibration and Measurement Capability (CMC) Expressed as an Expanded Uncertainty (k = 2) Remarks ELECTRICAL DC Resistance 0 to 33 33 to 330 330 to 3.3 k 3.3 k to 33 k 33 k to 330 k 330 k to 3.3 M 3.3 M to 33 M 2.8 m 8.1 m 54 m 0.59 5.7 77 3.3 k 0 Ω to 10 Ω 10 Ω to 100 Ω 0.1 kΩ to 1 kΩ 1 kΩ to 10 kΩ 10 kΩ to 100 kΩ 0.1 MΩ to 1 MΩ 1 MΩ to 10 MΩ 0.67 mΩ 1.8 mΩ 11 mΩ 0.13Ω 1.8 Ω 19 Ω 0.58 kΩ Generation 0 mV to 330 mV 330 mV to 3.3 V 3.3 V to 33 V 33 V to 330 V 330 V to 1020 V 4.0 V 19 V 0.25 mV 3.1 mV 19mV Measurement 0 mV to 100 mV 0.1 V to 1 V 1 V to 10 V 10 V to 100 V 100 V to 1000 V 2.8 µV 5.9 µV 0.11 mV 1.4 mV 9.2 mV 0 A to 3.3 mA 3.3 mA to 33 mA 33 mA to 330 mA 330 mA to 2.2 A 2.2 A to 11 A 0.11 µA 1.1 A 7.8 A 0.15 mA 1.6 mA Generation Measurement Four wire connections used Up to 10 kΩ, 2 wire above. DC Voltage DC Current Generation Assessment Manager: GM Page 1 of 3 S c he dul e of Ac c r e di ta ti on issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 0811 Acute Sales Limited Accredited to Issue No: 012 ISO/IEC 17025:2005 Issue date: 10 May 2016 Calibration performed at main address only Measured Quantity Instrument or Gauge Range Calibration and Measurement Capability (CMC) Expressed as an Expanded Uncertainty (k = 2) Remarks DC Current (cont’d) Measurement 0 µA to 100 µA 0.1 mA to 1 mA 1 mA to 10 mA 10 mA to 100 mA 0.1 A to 1 A 1 A to 10 A 17 nA 51 nA 1.7 µA 11 µA 0.10 mA 3.4 mA At 45 Hz to 1.0 kHz: 1.0 mV to 33 mV 33 mV to 330 mV 0.33 V to 3.3 V 3.3 V to 33 V 33 V to 330 V 330 V to 700 V 3.8 V 11 V 94 V 2.1 mV 23 mV 77 mV At 60 Hz: 10 mV to 100 mV 0.1 V to 1 V 1 V to 10 V 10 V to 100 V 100 V to 1000 V 16 µV 0.11 mV 3.6 mV 36 mV 0.38 V 45 Hz to 1.0 kHz: 29 A to 330 A 0.33 mA to 3.3 mA 3.3 mA to 33 mA 33 mA to 330 mA 0.33 A to 2.2 A 2.2 to 11 A 55 nA 0.75 A 2.5 A 30 A 0.47 mA 6.5 mA At 60 Hz: 10 µA to 100 µA 0.1 mA to 1 mA 1 mA to 10 mA 10 mA to 100 mA 0.1 A to 1 A 1 A to 10 A 34 nA 0.15 µA 2.0 µA 19 µA 0.33 mA 4.7 mA AC Voltage Generation Measurement AC Current Generation Measurement Assessment Manager: GM Page 2 of 3 S c he dul e of Ac c r e di ta ti on issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 0811 Acute Sales Limited Accredited to Issue No: 012 ISO/IEC 17025:2005 Issue date: 10 May 2016 Calibration performed at main address only Measured Quantity Instrument or Gauge Range Calibration and Measurement Capability (CMC) Expressed as an Expanded Uncertainty (k = 2) Remarks Frequency Generation 100 Hz to 1.0 kHz 60 mHz 100 kHz 6.0 Hz Electrical simulation and Measurement of thermocouples At 3.0 V With or without automatic cold junction correction E J K N - 250 °C to + 1000 °C - 210 °C to + 1200 °C - 200 °C to + 1372 °C - 200 °C to + 1300 °C 0.28 °C 0.27 °C 0.23 °C 0.22 °C T - 250 °C to + 400 °C 0.23 °C 80 kPa to 115 kPa 24 Pa Calibration of pressure devices with an electrical output 0 Pa to 20 kPa 20 kPa to 70 kPa 70 kPa to 270 kPa 270 kPa to 3.5 MPa 3.5 MPa to 7 MPa 7 MPa to 70 MPa 4.9 Pa 40 Pa 0.013 % + 15 Pa 0.012 % 1.8 kPa 21 kPa Absolute pressure calibrations can be undertaken using associated barometric pressure measurement correction. The uncertainties quoted will be increased by 24 Pa 0 Pa to 7 MPa 7 MPa to 70 MPa 2.1 kPa 21 kPa PRESSURE Gas pressure Barometric (Absolute) Calibration of pressure indicating instruments and gauges Pneumatic (gauge) Calibration of pressure indicating instruments and gauges Hydraulic pressure (gauge) Calibration of pressure indicating instruments and gauges END Assessment Manager: GM Page 3 of 3