Excel Life™ Programmable Time Delay Switch Mechanism (3

advertisement
Data Sheet
Excel Life™
Programmable Time Delay Switch
Mechanism (3-Wire), All Load
CAT NO.
EM803TDUG, EM803TDWE
Cat No
EM803TDWE
Description
Colour
Supply voltage
Max Load
EM803TDUG
1 Gang Programmable Time Delay Mechanism
White
Urban Grey
240V a.c.
5A (Refer to load chart back page)
LED Colour
Programmable - Blue or Red (Default)
Time Delay
Programmable from 1 to 60 min (5min Default)
Screw Terminal Size
Size
Compatible with
Compliance
1 x 2.5mm2 or 2 x 1.5mm2
21mm W x 21mm H x 50mm D
Excel LifeTM Plates or Panel Mount Adaptors (Available in WE only)
AS/NZS 3100
Excel Life™
All Load Programmable Time Delay
Switch Mechanism (3-Wire)
CAT NO.
EM803TDUG, EM803TDWE
Single product
Cat No
Dimensions
Weight
Barcode
EM803TDWE
145W x 90H x 25Dmm
0.03kg
9321001434030
EM803TDUG
145W x 90H x 25Dmm
0.03kg
9321001434559
Inner box (QTY 10)
■S
uitable for all commercial and domestic applications.
ie. passage lights, common area lighting
■ Compatible with all loads (including LED devices)
■ 3 Wire technology soft touch electronic push button
■ Time delay from 1 to 60 min (5 min Default)
■ Can be controlled from Slave (Cat No EM800SLAVEWE/UG)
■ Programmable LED indicator, Blue or Red (Default)
■ Programmable LED indicator intensity (see chart below)
■ Program parameters stored in a non-volatile memory
■ Easy screw terminal connection
■ Complies to Australian Standards AS/NZS 3100
■ Available in White and Urban Grey
Cat No
Dimensions
Weight
Barcode
EM803TDWE
162W x 126H x 83Dmm
0.35kg
9321001434047
EM803TDUG
162W x 126H x 83Dmm
0.35kg
9321001434566
Outer box (QTY 120)
Cat No
Dimensions
Weight
Barcode
EM803TDWE
350W x 270H x 270Dmm
4.7kg
9321001434054
EM803TDUG
350W x 270H x 270Dmm
4.7kg
9321001434573
Wiring
Connect optional Secondary Control Buttons (EM800SLAVE)
to enable switching from multiple locations.
ACTIVE
EM803TD
LOAD
ACTIVE
NEUTRAL
REMOTE
LOAD
NEUTRAL
LED Indicator
Status of LED indicator
Mode
Switch on
Switch off
1 (default)
Bright red
Faint red
2
Bright blue
Faint blue
3
Bright red
Off
4
Bright blue
Off
Important:
An unlimited number of EM800SLAVE can be
connected to an EM803TD. However, the total
length of the remote wire used to interconnect all
of the EM800SLAVE should not exceed 50 metres.
EM800SLAVE
ACTIVE
REMOTE
LOOP
Important:
Power factor correction capacitors must be either
removed or placed on the line side of the EM803TD.
EM800SLAVE
Load Chart
+ 50°C
Incandescent
Halogen
Fluorescent tube
Wirewound
transformer
Electronic
transformer
Compact
fluorescent
LED
Fan
motor
1200W
1200W
500VA
500VA
500VA
500VA
500VA
500VA
+ 0°C
1 x 2.5 mm²
2 x 1.5 mm²
Max load
HPM Legrand - AUS
1300 369 777
www.legrand.com.au
ABN 31 000 102 661
HPM Legrand - NZ
0800 476 009
www.legrand.co.nz
Refer to your group buying office, HPM Legrand Sales Representative or
HPM Legrand Sales Office for pricing.
Please note: specifications are subject to change without prior notice.
06_2014
230 - 240V a.c.
50Hz
Download