Data Sheet Excel Life™ Programmable Time Delay Switch Mechanism (3-Wire), All Load CAT NO. EM803TDUG, EM803TDWE Cat No EM803TDWE Description Colour Supply voltage Max Load EM803TDUG 1 Gang Programmable Time Delay Mechanism White Urban Grey 240V a.c. 5A (Refer to load chart back page) LED Colour Programmable - Blue or Red (Default) Time Delay Programmable from 1 to 60 min (5min Default) Screw Terminal Size Size Compatible with Compliance 1 x 2.5mm2 or 2 x 1.5mm2 21mm W x 21mm H x 50mm D Excel LifeTM Plates or Panel Mount Adaptors (Available in WE only) AS/NZS 3100 Excel Life™ All Load Programmable Time Delay Switch Mechanism (3-Wire) CAT NO. EM803TDUG, EM803TDWE Single product Cat No Dimensions Weight Barcode EM803TDWE 145W x 90H x 25Dmm 0.03kg 9321001434030 EM803TDUG 145W x 90H x 25Dmm 0.03kg 9321001434559 Inner box (QTY 10) ■S uitable for all commercial and domestic applications. ie. passage lights, common area lighting ■ Compatible with all loads (including LED devices) ■ 3 Wire technology soft touch electronic push button ■ Time delay from 1 to 60 min (5 min Default) ■ Can be controlled from Slave (Cat No EM800SLAVEWE/UG) ■ Programmable LED indicator, Blue or Red (Default) ■ Programmable LED indicator intensity (see chart below) ■ Program parameters stored in a non-volatile memory ■ Easy screw terminal connection ■ Complies to Australian Standards AS/NZS 3100 ■ Available in White and Urban Grey Cat No Dimensions Weight Barcode EM803TDWE 162W x 126H x 83Dmm 0.35kg 9321001434047 EM803TDUG 162W x 126H x 83Dmm 0.35kg 9321001434566 Outer box (QTY 120) Cat No Dimensions Weight Barcode EM803TDWE 350W x 270H x 270Dmm 4.7kg 9321001434054 EM803TDUG 350W x 270H x 270Dmm 4.7kg 9321001434573 Wiring Connect optional Secondary Control Buttons (EM800SLAVE) to enable switching from multiple locations. ACTIVE EM803TD LOAD ACTIVE NEUTRAL REMOTE LOAD NEUTRAL LED Indicator Status of LED indicator Mode Switch on Switch off 1 (default) Bright red Faint red 2 Bright blue Faint blue 3 Bright red Off 4 Bright blue Off Important: An unlimited number of EM800SLAVE can be connected to an EM803TD. However, the total length of the remote wire used to interconnect all of the EM800SLAVE should not exceed 50 metres. EM800SLAVE ACTIVE REMOTE LOOP Important: Power factor correction capacitors must be either removed or placed on the line side of the EM803TD. EM800SLAVE Load Chart + 50°C Incandescent Halogen Fluorescent tube Wirewound transformer Electronic transformer Compact fluorescent LED Fan motor 1200W 1200W 500VA 500VA 500VA 500VA 500VA 500VA + 0°C 1 x 2.5 mm² 2 x 1.5 mm² Max load HPM Legrand - AUS 1300 369 777 www.legrand.com.au ABN 31 000 102 661 HPM Legrand - NZ 0800 476 009 www.legrand.co.nz Refer to your group buying office, HPM Legrand Sales Representative or HPM Legrand Sales Office for pricing. Please note: specifications are subject to change without prior notice. 06_2014 230 - 240V a.c. 50Hz