Softswitch128® Switching Systems Power Equipment ne-xps-1 12.05.08 Combination Normal/Emergency Softswitch128® Panel – Feed-Through Only Standard-size Softswitch128 feed-through panels are available with internal separation allowing normal and emergency circuits to be wired into the same enclosure. Normal circuits are wired into the top section of the enclosure. Emergency circuits are wired into the bottom section of the enclosure. Each section is controlled by its own Softswitch128 controller, and the sections are considered as separate panels during system programming. Normal section Emergency section Panel with cover Combination Normal/Emergency Softswitch128 panel R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 1 Softswitch128® Switching Systems Power Equipment ne-xps-2 12.05.08 How to Build a Model Number for Combination Normal/Emergency Softswitch128® Panel X P S 2 8 - E M 8 - FT - C G P _ _ _ _ Prefix Number of Emerg. Circuits Number of Normal Circuits Custom Panel Suffix Feed Prefix XPS for Softswitch128 panels Number of Normal Circuits Total number of normal circuits (switch legs) in the panel Number of Emergency Circuits Total number of emergency circuits (switch legs) in the panel Feed FT for feed-through panels. Custom Panel Suffix Indicates panel with special options. Combination Normal/Emergency Softswitch128® Panel Models Combination Normal/Emergency Softswitch128 Feed-Through Panels for 120/277 V Normal Switch Legs Emergency Switch Legs Feed Type Maximum Feed 8 12 16 20 24 28 4 4 4 4 4 4 FeedThrough 20 A R or or or or or or 8 8 8 8 8 8 S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 2 Softswitch128® Switching Systems Power Equipment ne-xps-3 12.05.08 Combination Normal/Emergency Softswitch128® Panel Dimensions 14.375 (365) Suggested Mounting Height: Mount Standard Softswitch128 panel at a height of 26 in (660 mm), measured from floor to bottom of panel, for optimal LCD viewing. Top View 15.875 (403) 4.21 (107) 2.43 (62) 8.00 (203) 0.150 (4) 2.69 (68) 41.75 (1060) Cover 59.50 (1511) 59.00 (1499) Left Side View 2.43 (62) 11.00 (279) Right Side View 15.125 (394) Front View Bottom View 4.15 (105) Dimensions in inches (mm). R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 3 Softswitch128® Switching Systems Power Equipment ne-xps-4 12.05.08 Combination Normal/Emergency Softswitch128® Panel Wiring Overview Wire as shown. Use a trough when the Softswitch128 panel is not adjacent to a distribution panel. Splice Neutrals in trough. Do not remove bypass jumpers until load wiring is verified. Circuit Breaker Hot H SH H Switched load Wiring: Normal power section SH H SH Each switched circuit requires a dedicated 20 A circuit breaker and feed wiring to/from a normal power distribution panel, by others. Load H SH XP switching module (4 circuits) Neutral Ground bus Wire Sizes • 14 AWG (2.5 mm2) to 10 AWG (4.0 mm2) for feed wiring and switched load wiring • Power (Hot/Live) and switched Hot/Live connect directly to terminal block for switch legs Normal Softswitch128 controller Ground bus Switched load Wiring: Emergency power section Circuit breaker Each switched circuit requires a dedicated 20 A circuit breaker and feed wiring to/from an emergency power distribution panel, by others. Hot H SH Emergency Softswitch128 controller H SH H SH Load H SH Neutral R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 4 Softswitch128® Switching Systems Power Equipment ne-xps-5 12.05.08 Combination Normal/Emergency Softswitch128® Panel Dual-Voltage Control Feed Wiring Combination Normal/Emergency Softswitch128 panels are dual-voltage type and may be fed with either 120 V or 277 V . Wire to either the 120 V or the 277 V control feed terminals, not both. The terminals for the unused voltage will remain empty. Ground 277 V control feed 277 V 277 V 277 V Neutral OR 120 V control feed N N Neutral N Normal Feed Wiring { Do not wire to these terminals Ground 120 V * 120 V Ground 277 V control feed 277 V 277 V 277 V Neutral OR 120 V control feed N N Neutral N Emergency Feed Wiring { Do not wire to these terminals Ground 120 V * 120 V * Note: 120 V Hot terminal is protected by an internal fuse in case 277 V A spare fuse is also supplied in the panel. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: is mistakenly applied. Page 5 Softswitch128® Switching Systems Power Equipment ne-xps-6 12.05.08 Low-Voltage PELV (Class 2: USA) Wiring Overview for Combination Normal/Emergency Softswitch128® Panel • Connect low-voltage PELV (Class 2: USA) wiring to each of the two Softswitch128 controllers in the panel. • PELV (Class 2: USA) wiring between the two controllers must be run outside the panel. • The normal section and the emergency section each counts as a single panel on the control link. (Combination Normal/Emergency panel counts as 2 out of 16 allowable panels in the system). Combination Normal/Emergency Softswitch128 panel OMX-AV FOMX-1B OMX-CCO-8 SO-7B Up to 32 control stations Up to 16 panels PELV (Class 2: USA) wiring link requires: • Two 12 AWG (2.5 mm2) conductors for control wiring. • One shielded, twisted pair 18 AWG (1.0 mm2) for data link. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 6