XP Switching Panels GRAFIK Systems Power Equipment ne-xp-1 12.05.08 Combination Normal/Emergency Softswitch® Panel – Feed-Through Only Standard-size Softswitch feed-through panels are available with internal separation allowing normal and emergency circuits to be wired into the same enclosure. Normal circuits are wired into the top section of the enclosure. Emergency circuits are wired into the bottom section of the enclosure. Each section is controlled by its own Softswitch controller, and the sections are considered as separate panels during system programming. Normal Section Emergency Section Panel with cover Combination Normal/Emergency Softswitch Panel R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 1 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-2 12.05.08 How to Build a Model Number for Combination Normal/Emergency Softswitch® Panel X P 2 8 - E M 8 - FT - C G P _ _ _ _ Prefix Number of Emerg. Circuits Number of Normal Circuits Custom Panel Suffix Feed Prefix XP for Softswitch panels Number of Normal Circuits Total number of normal circuits (switch legs) in the panel Number of Emergency Circuits Total number of emergency circuits (switch legs) in the panel Feed FT for feed-through panels Custom Panel Suffix Indicates panel with special options Combination Normal/Emergency Softswitch® Panel Models Combination Normal/Emergency Softswitch Feed-Through Panels for 120/277 V Normal Switch Legs Emergency Switch Legs 4 8 12 16 20 24 28 4 4 4 4 4 4 4 R or or or or or or or 8 8 8 8 8 8 8 Feed Type Maximum Feed Feedthrough 20 A S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 2 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-3 12.05.08 Combination Normal/Emergency Softswitch® Panel Dimensions 14.375 (365) Top View 15.875 (403) 4.21 (107) 2.43 (62) 8.00 (203) 0.150 (4) 2.69 (68) 41.75 (1060) Cover 59.50 (1511) 59.00 (1499) Left Side View 2.43 (62) 11.00 (279) Right Side View 15.125 (394) Front View Bottom View 4.15 (105) All dimensions in inches (mm). R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 3 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-4 12.05.08 Combination Normal/Emergency Softswitch® Panel Wiring Overview Wire as shown. Use a trough when the Softswitch panel is not adjacent to a distribution panel. Splice Neutrals in trough. Do not remove bypass jumpers until load wiring is verified. Circuit breaker Hot H SH H Switched load Wiring: Normal power section SH H SH Each switched circuit requires a dedicated 20 A circuit breaker and feed wiring to/from a normal power distribution panel, by others. Load H SH XP Switching Module (4 circuits) Neutral Ground bus Wire Sizes • 14 AWG (2.5 mm2) to 10 AWG (4.0 mm2) for feed wiring and switched load wiring • Power (Hot/Live) and switched Hot/Live connect directly to terminal block for switch legs Normal circuit selector Ground bus Switched load Wiring: Emergency power section Each switched circuit requires a dedicated 20 A circuit breaker and feed wiring to/from an emergency power distribution panel, by others. Circuit breaker Hot H SH Emergency circuit selector H SH H SH Load H SH Neutral R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 4 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-5 12.05.08 Combination Normal/Emergency Softswitch® Panel Dual-Voltage Control Feed Wiring Combination Normal/Emergency Softswitch Panels are dual-voltage type and may be fed with either 120 V or 277 V . Wire to either the 120 V or the 277 V control feed terminals, not both. The terminals for the unused voltage will remain empty. Ground 277 V control feed 277 V 277 V 277 V Neutral OR 120 V control feed N N Neutral N Normal Feed Wiring { Do not wire to these terminals Ground 120 V * 120 V Ground 277 V control feed 277 V 277 V 277 V Neutral OR 120 V control feed N N Neutral N Emergency Feed Wiring { Do not wire to these terminals Ground 120 V * 120 V * Note: 120 V Hot terminal is protected by an internal fuse in case 277 V spare fuse is also supplied in the panel. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: is mistakenly applied. A Page 5 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-6 12.05.08 PELV (Class 2: USA) Wiring Overview for Combination Normal/Emergency Softswitch® Panel System communications use low-voltage PELV (Class 2: USA) wiring. Wiring must be daisy-chained. Wiring must run separately from line (mains) voltage. GRAFIK Eye® 4000 System PELV (Class 2: USA) wiring link requires: Two 12 AWG (2.5 mm2) conductors for control power. One twisted, shielded pair of 18 AWG (1.0 mm2) for data link. One 18 AWG (1.0 mm2) conductor for Emergency (Essential) sense line, from panel to panel. Total length of control link may be no more than 2,000 ft. (610 m). Approved low-voltage cable is available from Lutron,1 Belden, and Liberty. These are approved with 22 AWG data link wires. XP Panel Control Interface Wallstations Control Unit GRAFIK 5000TM/6000®/7000® System PELV (Class 2: USA) wiring link requires: Two 12 AWG (2.5 mm2) conductors for control power. One twisted, shielded pair of 18 AWG (1.0 mm2) for data link. One 18 AWG (1.0 mm2) conductor for emergency (essential) sense line, from panel to panel. Total length of control link may be no more than 2,000 ft. (600 m). If MUX-RPTR interface and GRX-CBL-46L cable1 is used, length may be up to 4,000 ft. (1200 m). XP Panel Processor Panel Control Interface Control Unit Power Panel Link 1 Wallstations Refer to GRAFIK 5000/6000/7000 Specification GRX-CBL-46L PELV (Class 2: USA) wiring cable is available from Lutron and contains: Two 12 AWG (2.5 mm2) conductors for control power. One twisted, shielded pair of 22 AWG (0.625 mm2) for data link. One 18 AWG (1.0 mm2) conductor for emergency (essential) sense line. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 6 XP Switching Panels GRAFIK Systems Power Equipment ne-xp-7 12.05.08 PELV (Class 2: USA) Panel-to-Panel Wiring for Combination Normal/Emergency Softswitch® Panel Data link (1) shielded, twisted pair 18 AWG (1.0 mm2) 3: MUX 4: MUX Control wiring (2) 12 AWG (2.5 mm2) 1: Common 2: 24 V To additional 1 power panels 2 (1) 18 AWG (1.0 mm2) 5: Sense line 1 2 3,4 To lighting controls or processors 3,4 Shield/Drain Shield/Drain 1 2 3 4 D 5 1 2 3 4 D 5 C D SELECT CIRCUIT 1 2 3 4 D 5 MUX Link MUX Link A B Drain Data B OK Power Common MUX +24VFW Data A OK MUX MUX Link MUX Link A B Drain Data B OK Power Common MUX Drain Sense +24VFW MUX Common Data A OK Drain Sense 1 2 3 4 D 5 Common 5 C D SELECT CIRCUIT 1 1 2 2 Circuit XP Panel Normal section Circuit XP Panel Emergency section (4) 12 AWG (2.5 mm2) Notes: Each low-voltage PELV (Class 2: USA) terminal can accept only two 18 AWG (1.0 mm2) wires. Two 12 AWG (2.5 mm2) conductors will not fit. Connect as shown. 1 2 3 4 D 5 A BC Drain Link Comm Link MUX Data B OK Power MUX Drain Sense MUX Data A OK 24VFW MUX PELV (Class 2: USA) Terminal Connections 1 2 3 4 D 5 Common • Emergency power: The additional 18 AWG (1.0 mm2) wire is a “sense” line from terminal 5 of another panel. This sense line allows an Emergency (Essential) lighting panel to “sense” when Normal (Non-Essential) power is lost. If more than one Emergency lighting panel needs to sense from a specific normal panel, a dedicated wire between each pair of Normal (Non-Essential) and Emergency (Essential) panels may be required. • Shield/Drain: Connect shielding as shown. Do not connect to Ground (Earth) or circuit selector. Connect the bare drain wires and cut off the outside shield. D S ELECT CIRCUIT 1 2 Circuit R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 7