Combination Normal/Emergency Softswitch® Panel –
Feed-Through Only
Standard-size Softswitch feed-through panels are available with internal separation allowing normal and
emergency circuits to be wired into the same enclosure. Normal circuits are wired into the top section of the
enclosure. Emergency circuits are wired into the bottom section of the enclosure. Each section is controlled by
its own Softswitch controller, and the sections are considered as separate panels during system programming.
Normal Section
Emergency Section
Panel with cover
Combination
Normal/Emergency
Softswitch Panel
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 1
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-2 12.05.08
How to Build a Model Number for Combination Normal/Emergency
Softswitch® Panel
X P 2 8 - E M 8 - FT - C G P _ _ _ _
Prefix
Number
of Emerg.
Circuits
Number
of Normal
Circuits
Custom Panel
Suffix
Feed
Prefix
XP for Softswitch panels
Number of Normal Circuits
Total number of normal circuits (switch legs) in the panel
Number of Emergency Circuits
Total number of emergency circuits (switch legs) in the panel
Feed
FT for feed-through panels
Custom Panel Suffix
Indicates panel with special options
Combination Normal/Emergency Softswitch® Panel Models
Combination Normal/Emergency Softswitch
Feed-Through Panels for 120/277 V
Normal
Switch Legs
Emergency
Switch Legs
4
8
12
16
20
24
28
4
4
4
4
4
4
4
R
or
or
or
or
or
or
or
8
8
8
8
8
8
8
Feed
Type
Maximum
Feed
Feedthrough
20 A
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 2
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-3 12.05.08
Combination Normal/Emergency Softswitch® Panel Dimensions
14.375
(365)
Top View
15.875
(403)
4.21
(107)
2.43 (62)
8.00
(203)
0.150
(4)
2.69 (68)
41.75 (1060)
Cover
59.50 (1511)
59.00
(1499)
Left Side View
2.43 (62)
11.00
(279)
Right Side View
15.125
(394)
Front View
Bottom View
4.15 (105)
All dimensions in inches (mm).
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 3
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-4 12.05.08
Combination Normal/Emergency Softswitch® Panel
Wiring Overview
Wire as shown. Use a trough when the Softswitch panel is not adjacent to a distribution panel.
Splice Neutrals in trough.
Do not remove bypass jumpers until load wiring is verified.
Circuit breaker
Hot
H
SH
H
Switched load
Wiring: Normal
power section
SH
H
SH
Each switched
circuit requires a
dedicated 20 A
circuit breaker and
feed wiring to/from a
normal power
distribution panel, by
others.
Load
H
SH
XP Switching
Module
(4 circuits)
Neutral
Ground bus
Wire Sizes
• 14 AWG (2.5 mm2) to 10 AWG (4.0 mm2) for feed
wiring and switched load wiring
• Power (Hot/Live) and switched Hot/Live connect
directly to terminal block for switch legs
Normal
circuit
selector
Ground bus
Switched load
Wiring: Emergency
power section
Each switched
circuit requires a
dedicated 20 A
circuit breaker and
feed wiring to/from
an emergency
power distribution
panel, by others.
Circuit breaker
Hot
H
SH
Emergency
circuit
selector
H
SH
H
SH
Load
H
SH
Neutral
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 4
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-5 12.05.08
Combination Normal/Emergency Softswitch® Panel
Dual-Voltage Control Feed Wiring
Combination Normal/Emergency Softswitch Panels are dual-voltage type and may be fed with either
120 V
or 277 V
.
Wire to either the 120 V
or the 277 V
control feed terminals, not both. The terminals for the unused
voltage will remain empty.
Ground
277 V
control
feed
277 V
277 V
277 V
Neutral
OR
120 V
control
feed
N
N
Neutral
N
Normal
Feed
Wiring
{
Do not wire to
these terminals
Ground
120 V
*
120 V
Ground
277 V
control
feed
277 V
277 V
277 V
Neutral
OR
120 V
control
feed
N
N
Neutral
N
Emergency
Feed
Wiring
{
Do not wire to
these terminals
Ground
120 V
*
120 V
* Note: 120 V
Hot terminal is protected by an internal fuse in case 277 V
spare fuse is also supplied in the panel.
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
is mistakenly applied. A
Page 5
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-6 12.05.08
PELV (Class 2: USA) Wiring Overview for Combination
Normal/Emergency Softswitch® Panel
System communications use low-voltage PELV (Class 2: USA) wiring.
Wiring must be daisy-chained.
Wiring must run separately from line (mains) voltage.
GRAFIK Eye® 4000 System
PELV (Class 2: USA) wiring link requires:
Two 12 AWG (2.5 mm2) conductors for control power.
One twisted, shielded pair of 18 AWG (1.0 mm2) for data link.
One 18 AWG (1.0 mm2) conductor for Emergency (Essential) sense line, from panel to panel.
Total length of control link may be no more than 2,000 ft. (610 m).
Approved low-voltage cable is available from Lutron,1 Belden, and Liberty. These are approved with 22
AWG data link wires.
XP Panel
Control Interface
Wallstations
Control Unit
GRAFIK 5000TM/6000®/7000® System
PELV (Class 2: USA) wiring link requires:
Two 12 AWG (2.5 mm2) conductors for control power.
One twisted, shielded pair of 18 AWG (1.0 mm2) for data link.
One 18 AWG (1.0 mm2) conductor for emergency (essential) sense line, from panel to panel.
Total length of control link may be no more than 2,000 ft. (600 m).
If MUX-RPTR interface and GRX-CBL-46L cable1 is used, length may be up to 4,000 ft. (1200 m).
XP Panel
Processor
Panel
Control Interface
Control Unit
Power Panel Link
1
Wallstations
Refer to GRAFIK 5000/6000/7000 Specification
GRX-CBL-46L PELV (Class 2: USA) wiring cable is available from Lutron and contains:
Two 12 AWG (2.5 mm2) conductors for control power.
One twisted, shielded pair of 22 AWG (0.625 mm2) for data link.
One 18 AWG (1.0 mm2) conductor for emergency (essential) sense line.
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 6
XP Switching Panels
GRAFIK Systems
Power Equipment
ne-xp-7 12.05.08
PELV (Class 2: USA) Panel-to-Panel Wiring for
Combination Normal/Emergency Softswitch® Panel
Data link
(1) shielded,
twisted pair 18
AWG (1.0 mm2)
3: MUX
4: MUX
Control
wiring
(2) 12 AWG
(2.5 mm2)
1: Common
2: 24 V
To additional 1
power panels 2
(1) 18 AWG
(1.0 mm2)
5: Sense line
1
2
3,4
To lighting
controls or
processors
3,4
Shield/Drain
Shield/Drain
1 2 3 4 D 5
1 2 3 4 D 5
C
D
SELECT CIRCUIT
1 2 3 4 D 5
MUX
Link
MUX
Link
A B
Drain
Data B OK
Power
Common
MUX
+24VFW
Data A OK
MUX
MUX
Link
MUX
Link
A B
Drain
Data B OK
Power
Common
MUX
Drain
Sense
+24VFW
MUX
Common
Data A OK
Drain
Sense
1 2 3 4 D 5
Common
5
C
D
SELECT CIRCUIT
1
1
2
2
Circuit
XP Panel Normal section
Circuit
XP Panel Emergency section
(4) 12 AWG (2.5 mm2)
Notes:
Each low-voltage PELV (Class 2: USA) terminal can accept
only two 18 AWG (1.0 mm2) wires. Two 12 AWG (2.5 mm2)
conductors will not fit. Connect as shown.
1 2 3 4 D 5
A BC
Drain
Link
Comm
Link
MUX
Data B OK
Power
MUX
Drain
Sense
MUX
Data A OK
24VFW
MUX
PELV (Class 2: USA) Terminal Connections
1 2 3 4 D 5
Common
• Emergency power: The additional 18 AWG (1.0 mm2) wire is
a “sense” line from terminal 5 of another panel. This sense
line allows an Emergency (Essential) lighting panel to “sense”
when Normal (Non-Essential) power is lost. If more than one
Emergency lighting panel needs to sense from a specific
normal panel, a dedicated wire between each pair of Normal
(Non-Essential) and Emergency (Essential) panels may be
required.
• Shield/Drain: Connect shielding as shown. Do not connect to
Ground (Earth) or circuit selector. Connect the bare drain
wires and cut off the outside shield.
D
S ELECT CIRCUIT
1
2
Circuit
R
S P E C I F I C AT I O N S U B M I T TA L
Job Name:
Job Number:
Model Numbers:
Page 7
Download