SMARTBLO OCK 16 dataa sheet high h efficiency‐‐chpp Operatio onal mode Ma ains paralle el operation Fuel Natural gas s, LPG Electric output (Pel) Thermal output (Pth) 16 kW 37,5 kW m min. 8 kW m min. 25,1 kW incl. integ grated calorific value v use2) Fuel con nsumption CHPP coefficient 51,3 kW1) 0,43 cy Efficienc Total e efficiency Electric y c efficiency Therma al efficiency y DIN ISO 3046-1 actual value 104,3 % 32,2 % 73,1 % 101,1% Primary y energy sav vings3) Primary y energy facttor fPE,WV6) Total an nnual use effficiency3) 33,1 % 0,40 104,3 % 31,0 % Gas-con nnection pre essure Gas-flow w pressure Flow ratte with natural gaas 20-50 mbarr Ɓ 16 PEDU 5,0 Nm³/h (1 0,0 kWh/m³) Flow tem mperature Return ttemperature e max. 85°C max. 65°C Combus stion air req quirement min. 58 m³/ h (65kg/h) Ambient temperature 5°C to max.. 35 °C Exhaustt gas emissiions CO (ca arbon monoxide) NOx (n nitrogen oxide e) Exhaustt gas temperature Exhaus gas volume e flow Exhaus gas mass fllow dry p Exhaustt gas back pressure at 5 Vol% remaininng oxygen ~ 63 m³/h ~ 70 kg/h ar max. 5 mba Sound p pressure lev vel CHPP ~ 56 dB(A) (1 m distance)5) Output cu urve sb16 [kW Wth to kWel] 30,2 % 70,9 % 0,44 55 101,1 % 50 <100 mg/m³³ <100 mg/m³³ ~ 50 °C2) (<50% TA-air) (<50% TA-air) 45 40 35 30 11 after CS 75 70 65 60 55 50 45 40 CHPP: D Dimensions,, weights an nd connectio ons L x W x H CHPP w//o handles 1,27 x 0,82 x 0,98 m Weightt CHPP incl. oi + water 740 kg 0,30 x 1,52 m (w/o flanges) ø x H CS4) Weightt CS4) 30 kg Colourr CHPP Pantone 551 7C Heating R 3/4“ Flow ((warm) g connections (VL) R 3/4“ Returrn (cold) Exhausst gas connections CS4) DN100 (Jeremiias ew-kl) Gas co onnection R 3/4“ Hevac ltd unit A 1 Young g Place Kelvin Ind Est East Kiilbride G75 0TD 1355 242746 Email dmac@hevaac.ltd.uk .TEL 013555 248664 FAX 01 www.hevacc.ltd.uk 14 15 16 17 18 19 20 21 22 Consum mption curve sb16 [Nm³/h too kWel] 12 13 14 15 16 17 18 19 20 21 22 Efficiency E cu urves sb16 [% to kWel] total therm mal 50 electtric 0 8 9 10 11 12 13 14 15 16 50 So ound pressu ure level currve [dB(A) to Hz]]5) 40 30 K18 Straight engi ne (Otto) 4-stroke 3 1,8 litres 1500 1/min 13 11 12 100 4) Motor Type Operattion Cylinde er Displaccement Nomina al engine spe eed Continuoous modulation ra ange 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 According to t DIN ISO 3046-11, tolerance 5% Return-temperature 40°C 3) According to t EU RL 2004/8/E EG at 100% interna al use 4) Combinatio on silencer 5) Test stand measuring withoutt liability 6) According to t EnEVÄndV 20099: fPE -current = 2,6 6 1) 2) data sheet sm martblock 16 1 1/2 SMARTBLO OCK 16 dataa sheet high h efficiency‐‐chpp Cabinett: Dimension n and weight (Wall mo ounting, connecttions at the botto om, standard caable set 6m) LxWxH Weight Colour 0,40 x 0,19 x 0, 52 m 21 kg Pan ntone 5517C C Asynchrronous gene erator Cooling Powerr Voltage Nomina al current Freque ency Operatting mode We eier DKASGM M Water cooled 16 kW 400 0V 29 A 50 Hz S1 Electrica al data sma artblock 16 max. efffective powe er PAmax: max. apparent power SAmax: cos ij Nomina al voltage UN N: Rated ccurrent Ir: Grid inp put: 16 kW W 16,6 kkVA 0,97 400 V 24 A Three phase curren nt Isolated d operation in ntended? No Motor-d driven start in ntended? No Starting g current IA: 0,17 kkA Short ccircuit currentt I"K: Short ccircuit stabilityy of the comp plete 10 kA A system IK: Reactivve power com mpensation: existinng Numbe er of compensation steps:: 1 7,3 kV Reactivve power perr step: VAr Detunin ng factorrespectively 0 resonance frequenccy: 0,045 kVA Own re equirement: Connec ction to low voltage v grid d Version according to o VDE-AR-N 4105 "Produ uction systemss on low volta age grid – Te echnical minim mum requirem ments for the e connection to t low voltagee grid and parallel operation of production systems" s smart s block k 16 control BR06 Freely progra ammable SP PS control sysstem to control, adju ust, calculate,, measure an nd display results. The control systeem is equippe ed with a full graphics dis splay and all ffunction butto ons, required d to operate th he combinedd heat and po ower plant. Th he 5,7“ LCD dis splay shows information about a the system and its current sttatus. The BR06 can optionallyy be expande ed by a heatin ng control syste em, requirem ment peak loa ad boiler (up to t 2 boilers), da ata transfer vvia LAN and Internet with an a error notifica ation via emaiil (only with DSL) D and an interface con nnection to eexternal syste ems (Etherne et UDP, Mod-B Bus RTU/TCP P, RK512, 39 964R). Additionally, the CHPP ccan be conne ected to virtua al power plantts using VHP--Ready and net.storm. n Settings s grid protec ction (VDE-A AR-N 4105) Voltage e drop protecction U< 0,8 Un (100 ms) Voltage e increase pro otection U> 1,1 Un (100 ms) Voltage e increase pro otection U>> > 1,15 U n (100 ms) Frequency drop pro otection f< 47,5 H Hz (100 ms) Frequency increse protection p f> 51,5 H Hz (100 ms) Integratted grid prottection Circuit breaker 35 A Typ: K Standard refference conditionss according to DIN N ISO 3046-1: Thee technical data are based on naturral gas H with a heeating value of 10,0 kWh/Nm3 (Totaal air pressure 100 0 kPa, air tempera ature 25 °C, relative e humidity 30 %, 1100m above sea le evel). Power adjusttment at ambient cconditions accordin ng to DIN ISO 304 461 respectivelly DIN 6271-3. Th he tolerance of the e specific fuel con sumption is +5% at nominal power and the tolerancee of the usable the ermal output is 7% % at nominal pow wer. We reserve the t right to change data and cha racteristics withou ut prior notice in accordance with our business policy and the ongo oing development process. Hevac ltd unit A 1 Young g Place Kelvin Ind Est East Kiilbride G75 0TD 1355 242746 Email dmac@hevaac.ltd.uk .TEL 013555 248664 FAX 01 www.hevacc.ltd.uk data sheet sm martblock 16 1 2/2