PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controlleris easy to program, using the familiar ladder diagram format. Functional capabilities include relay logic, timers, counters, sequencers, and shift registers. The controller can be used in a wide variety of applications, including: 0 The PrOC@SSOr Unit Machine tools Material handling 0 0 Assembly machines Molding and casting machines Contains the processor (CPU and battery-backedCMOS RAM memory), a power supply, and16 I/O circuits. It is available in four versions to meet various application requirements. Peripheral devices: EEPROM Memory Module - Plugs into the processor unit for program loading and storage. Pocket Programmer - Connect the programmerto the processor-unit to program, monitor, edit, and troubleshoot. The nine operating modes selected withthe programmer: 1: Clear Memory 2: Program 3: Run 4: Test-Single Scan 5: Test-Continuous Scan 6: Store Program in EEPROM 7: Load Program from EEPROM 8: EnteriChange Access Code 9: DiagnosticTest-Programmer Personal Computer Software- Allows you to use an IBM or IBMcompatible personal computer in place of the pocket programmer. With the software,you can select functions equivalent to the modes defined above. Additional capabilities: off-line programming and program library development; ladder diagram display and enhancements; data display and cross reference table generation; program print-out. An RS232-CIRS-422 interface converter is required for communication between the processor and computer. Timer CounterAccess Terminal (TCAT)- Allows production, supervisory, and maintenance people tomonitor programmed timer, counter, and sequencer data "on-line". Connected by cable to the processor unit. I/O Expansion Units - There are threeSLC 100 I/O expansion unitsthe basic expansion unit, the relay output expansion unit, and the analog input expansion unit. These units can be interconnected with the processor unit to expand the number and type of I/O circuits. You can also connect theSLC 150 I/O expansion unit to the SLC 100 processor unit. The maximum numberof I/O circuits is112. Publication 1745-2.1 -October, 1987 Supersedes Publication 1745-2.1 Dated August,1985 40065-230-01 (D) 2 Processor Unit - SLC 100 The following features are pointed out in the illustration on 3.Page 1. Incoming line wiring terminals. Self-lifting pressure plates allow for easy wire insertion and secure connections. Terminals accept two #14 AWG wires. A hingedcover is provided (but not illustrated). The cover needn’t be removed to gain access to the terminals. 2. Wiring terminalsfor 10 inputs. Same constructiona s line terminals. The hinged cover (not illustrated) has write-on areas for identification of external circuits. Cover is color-coded to identify the circuit voltage level. The cover needn’t be removed to gain access to the terminals. 3. Wiring terminalsfor 6 outputs. Same constructionas line terminals. Hinged cover (not illustrated) has write-on areas to identify external circuits. The coverneedn’t be removed to gain access to the terminals. The processor unit has relay (hard contact) output circuits. 4. Five LED diagnostic indicators: DC POWER (green) - Indicates that the processor unit is energized and DC power is being supplied. PC RUN (green) - Indicates the processor unit is in the Run mode. CPU FAULT (red) - Indicates the processor has detected an error in either the CPU or memory. Operation is automatically stopped. BATTERY LOW (red) - A batteryprovides back-up powerfor the CMOS RAM memory. This LED alerts you when the battery voltage level has fallen below a threshold level. FORCED I/O (amber) - Indicates that one or more input or output addresses have been forced to an ON or OFF state. 5 . Input power fuse (behind front cover). If line terminal voltage is present but theDC POWER LED is not lit, the fuse may blown. be Refer tothe User’s Manualfor fuse replacement procedure. 6. Input status indicators. Ten red LEDs, identified with address numbers 1 thru 10, corresponding to numbers1 thru 10 on the input device wiring terminals. Whenan input circuit is energized, the corresponding status indicator will be lit. 7. Output status indicators. Six red LEDs, identified with address numbers 11 thru 16, corresponding to numbers 11 thru 16 on the output contact wiring terminals. When a programmed output instruction is TRUE, the corresponding output status indicator will be lit, and the corresponding output contact will close. 8. Auto/Manual switch. This switch controls restarting of the processor unit after power a loss,brown-out, or correction of a CPU fault. Auto - On power-up, the processor runs thru its normal diagnostic tests and then automatically enters the Run mode (ifit was in the Run mode at the last power-down). Manual - On power-up, the processor runs thru its diagnostic tests but will not enter the Runmode. To enter the Run mode,you must move the switchto the autoposition or use thepocket programmer (or personal computer). 3 Processor Unit - SLC 100 (*) Auto’manua1 switch. Features (continued) (9) EEPROM memory module compartment. \ (3) Wiring terminals for 6 outputs. indicators. 9. EEPROM memorymodulecompartment. The optional memory module can be plugged into the processor. The pocket programmer or personal computer software allows you tostore your processorRAM program in the EEPROM.You can also loada program from the EEPROM into theDrocessor RAM. We recommend that you install an EEPROM memory module. This will provide maximum protection against user program loss or program alteration due to battery back-up drain, processor malfunction, or excessive noise. 10. Communication port. Thepocket programmer, interface converter, or TCAT cableis plugged into this socket. 11. Expansion unit connection. The expansion unit cable is plugged in . this socket. SLC 100 and SLC 150 expansion units can be interconnected to increase the I/O capacity of the controller. 12. Battery compartment. Back-up power for the CMOS RAM is provided by a replaceable battery assembly, accessible from the front of the processor unit. The lithium battery provides back-up power for approx. 2-3 years. Battery replacement: See the User’s Manual. 4 Processor Unit - SLC 100 The enclosure should be adequate (NEMA approved) for the environmental conditionsof the particular application. The processor unit, expansion units, and inputloutput device circuits should havethe samepower source. Theprocessor and expansion units should be properly grounded. Include a n electrical disconnect in the enclosure. An isolation transformer may alsobe required. A master control relay circuit should be included to permit disabling of the I10 devices independentof the processor and expansion unit power circuit. One or more emergency-stop switches should also be included. Follow recommendations for component spacing within the enclosure, to help keepthe controller temperature within the specified limits. Wiring should be routed to minimize electrical noise effects. Surge suppressors should beused forinductive loads in series with hard contacts and for other noise-generating equipment. to protect loads and wiring from short Fusing should be provided circuits or overloading. sslnting 1. Screw mounting: Theprocessor unit canbe mounted directlyto the #10 screws. Hole locationsare back panelof your enclosure using four shown in the dimension drawing below. 2. DIN rail mounting: The processor unit can be mounted in your enclosure ona 35 mm by 7.5 mm DIN mounting rail (Catalog No. 199-1DR). Two DIN rail fasteners are provided on the processor unit, The DIN rail canbe screwed, bolted,or welded tothe enclosure back panel. Install the processor unit by hanging the unit on the top of edge the DIN rail, then pressing the unit toward the rail ituntil snaps into place. To remove theprocessor unit, pry open the fasteners. 5 Processor Unit - SLC 100 Line Wiring Connections Makelineconnections as follows: CAUTION: Incorrect wire connections can cause damage to the processor unitpower supply. Do not jumper115VAC NEUT and 230VAC NEUT together. Do notjumper unused 115VAC NEUT or unused 230VAC NEUT to the CHASSIS GND terminal. 6 Processor Unit - SLC 100 put Wiring connections SLC 100 input circuitry is current sinking, compatible with current sourcing (PNP) input devices. Circuitryincludesopticalisolationand surge suppression to guard against damage by transients from user input devices. A direct interface to solid state sensing devices and SLC 100 controller output circuitsis possible because of the 2 mA OFF state leakage current specification, indicatedin thefollowing table. Note that the 2 mA value applies only to inputs 1and 2 in someunits. You can achievea 2 mA current valuefor inputs 3 thru 10by adding a resistor, as indicated. Catalog Number 1745-LP101 1745-LP102 1745-LP103 1745-LP104 Maximum OFF State Leakage Current To achieve a 2 mA OFF state leakage currentfor inputs 3 thru 10, connect a resistor input toterminal the from the COM terminal as shown the in wiring diagram. 2 mA, inputs 1 only and 2 0 @ Input terminal coverplates are color coded according to voltage: 115VAC -red, 230VAC -black, 24VDC -blue. I COM 1 4 I 2 3 I 4 5 COM 6 7 8 9 COM 10 4 4 COM terminals are connected together internally COM terminals are connected together internally 1745-LP103, -LP104 (DC input devices) 1745-LP101, -LPI02 To achieve a 2 mA OFF state leakage currentfor inputs3 thru 10, connect a resistor from the inputterminal to COM. 5.6K ohms, 112 watt min. I I COM terminalsare connected together internally 1745-LP103, -LP104 (AC input devices) I 7 Processor Unit - SLC 100 Output Wiring Connections Wiring connections for output devices are shown below. Note that the diagram shows the internally-connected output contacts and parallelRC networks. The RC networks guard against possible damageby transients from external output devices. External connectionsare shown for outputs11,15, and 16. We’ve added a suppressor in parallel with two of the external devices for the purposeof contact protection. Contact protectionis discussed on Page8. Since the output contacts are isolated from each other, each output circuit can be wired independently, with own its ground return. You can applya different voltage in each output circuit, as your application might require. Power or ground wires can be jumpered betweenof sets terminals if desired. You should provide appropriate fusing to protect the output devices and wiring from short circuits and overload conditions. I Solenoid 15VAC 1 L l (Hi) r I To limit theeffects of leakage current, use a loading resistor across the load as shown at the right. k L2 (Lo) 5VAC 1 1 L1 (Hi) Resistor 115VAC: 1 5 K o h r n , 2 w a t t 230VAC: 15K ohm, 5 w a t t I I 8 Processor Unit - S l C 100 Output Contact Protection Inductive output devices suchas motor starters andsolenoids may require thatyou use some type of surge suppression to protect the output contacts. Examples are shownbelow. These surge suppression circuits are connected directly across the output can device. The effect is to reduce arcingof the output contacts (arcing be voltage which occurs whenan inductive caused by the high transient device is switched offp. Suitable surge suppression methods for inductive AC output devices include a varistor, anRC network, and an Allen-Bradley surge suppressor. These components must be appropriately rated to suppress the switching transient characteristic of the particular inductive device. For inductive DC output devices,a diode is suitable.A 1N4004 diode is acceptable for most applications. A surge suppressor can also be used (refer to the User’s Manual). We recommend that you locate the suppression deviceas close as possible to the outputdevice. Suppressors recommended for use with Allen-Bradley relays, contactors, and motor starters are listed in the User’s Manual. 9 Processor Unit - SLC 100 General Specifications Shift Register: 8-bit groups. Noise Immunity: NEMA Standard ICs 2-230. Vibration: DIN Rail Mounting: 0.006 inch peak t o peak displacement, 1 .Og peak (max) acceleration, 1 Hr/axis. Screw Fastener Mounting: 0.01 5 inch peak t o peak displacement, 2.59 peak(max) acceleration,1 Hr/axis. Ambient Temperature Rating: 0" t o 60" C (operating). - 40"o 85" Humidity Rating: 5 t o 95% (without condensation). Wiring: #14 - #24 AWG stranded. 3/64" insulation (max). C (storage). 10 Processor Unit - SLC 100 Input SpeCifkatiOnS Input specifications for the various processor unit versionsare shown below. to The 2 mA OFF state leakage current specification allows direct interface solid state sensing devices. Note that the mA 2 OFF state leakage current for 24VAC circuits applies to inputs 1and 2 only. When required, you can also achieve 2a mA OFF state leakage currentfor inputs 3 thru 10, as indicated in the specifications. All input circuits include optical isolationwell as as filtering and surge by transients from external input suppression to guard against damage devices. ON State Voltage Range and Frequency: 1745-LP101: 85-1 32VAC, 50/60 HZ. 1745-LP102: 170-265 VAC, 50/60 HZ. 1745-LP103, -LP104: 10-30V, AUDC. Maximum OFF State Voltage: 1745-LP101:35V. 1745-LP102: 50V. 1745-LP103, -LP104: 5V. ' Maximum OFF State Leakage Current: 1745-LP101,-LP102: 2 mA. 1745-LP103, -LP104: ZmA, inputs 1 and 2 only. To achieve a 2 mA 0,FF state leakage current for inputs 3 thru 10, connect a 5.6KO, 1/2 watt (min) resistor from the input terminal to the common terminal. Nominal Input Current: 1745-LP101, -LP102: 8 mA. 1745-LP103, -LP104: Inputs 1 and 2- 8 mA a t 12V, 18 mA a t 24V. Inputs 3 thru 10- 6 mA a t 12V, 14 mA at 24V. Specifications applying t o all Catalog Numbers: input Filter Time Delay: 10-25 msec. Electrical-Optical Isolation: 1500 volts between input voltage and control logic. 11 Processor Unit - SLC 100 eationS Output specifications for all versionsof the processor unit are shown below. Internal output circuitry includes surge suppression to guard against possible damage by transients from external outputdevices. We of contact protection when recommend that you also use some type switching inductive load devices. Refer to Pages 7 and 8. Voltage Range and Frequency: 10-250 VAC (50/60 HZ), 10-125 VDC. Contact Ratings: 240VAC l2OVAC 0.75A 7.5A 2,5A 1.5A 15A 1800VA 180VA 125VDC 0.22A 1 .OA 28VA 24VDC 1.2A 2.5A 28VA Contact Resistance: 20 mR (typical). Electrical Isolation: 2000 volts. OFF State Leakage Current: 2 mA (AC voltage only). To limit leakage current use a loading resistor across the loadas shown on Page7. Output Fusing for OverloadProtection: Bussman 3A, 250VACslow blow or equivalent. Internal RC Network Values: R = 120 ohms, C = 0.022 microfarad. ALLEN-BRADLEY A ROCKWELL INTERNATIONAL COMPANY industrial Control Group Milwaukee, Wisconsin 53204