DALUME L I G H T I N G DRL11_RM - Sheet Rock Ceiling Recessed Mount FIG. A Framing Opening 12" x 12" R LIGHTING GROUP LOS ANGELES, CA SAVE THESE INSTRUCTIONS INSTALL AND USE THIS LUMINAIRE FOLLOWING THE NATIONAL ELECTRICAL CODE, YOUR LOCAL ELECTRICAL CODE AND REGULATIONS. 1 PREPARATION: 4x Wood Screw Recessed Frame EEMA 1). Read and understand instructions completely before installing this luminaire. If you are unfamiliar with electrical wiring have a qualified licensed electrician installs this luminaire. 2). Before proceeding the installation, be sure that the ceiling construction follows the proper requirements. 3). Custom Framing is required, Installer may build a wood joist framing as specified in FIG. A. Framing clearance and Sheet-rock (ceiling) Opening must be 12" x 12" x 6" Height. CAUTION! FIG. B (1x) 3/4" K.O. Recessed Luminaire FIG. C Wood Screws @ 1.75" Height FIG. D FINAL INSTALLATION 1-3/4" CEILING MOUNTED FIG. E WIRING DIAGRAM POWER SUPPLY Ground Wire Ground Wire Line (-) Wire NON-IC LUMINAIRES: Ceiling insulation must be kept a minimum of 3" away from the sides of the framing. No insulation allowed on the top. Install housing at a minimum of 1/2" away from combustible material such as sub-flooring or roofing. 2 INSTALLING LUMINAIRE RECESSED FRAME: NOTE: Ceiling (sheet-rock) must be installed prior to Luminaire Recessed Frame installation. 1). Place Recessed Frame into Ceiling Opening. Make sure the frame flanges are flush (level) with ceiling surface, then install Frame using Wood Screws (by others) as shown in illustration (see FIG. A). 2). In order to be able to install the Recessed Luminiare into the Frame, pass Electrical Supply through Frame and connect to Luminaire Electrical Box to make electrical connection (see FIG. E). 3 ELECTRICAL CONNECTIONS: 1). WARNING- Before starting the wire connections, disconnect the power by turning off the circuit breaker or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to prevent electrical shock. 2). This luminaire must be connected with supply wire rated at 90o C. Most dwellings built before 1985 have supply wire rated at 60o C; consult a qualified electrician before installing. 3). Connect the power source to the luminaire junction box. Connect the line (-) wire to the black wire of the power source, the neutral (+) wire to the white wire of the power source and connect the ground wire to the green ground wire of the power source using twist type wire connectors (by others) suitable for the size, type and number of wires; see wiring diagram (see FIG. E). 4). After completing the wiring (be sure the wires are placed within the electrical box), replace J-Box cover. 4 INSTALLING RECESSED LUMINAIRE: 1). Tilt Recessed Luminaire and insert it all away into the Frame in diagonal angle. Lens facing down (see FIG. B). 2). Let the Recessed Luminaire come down and rest on the Frame Flanges as shown in illustration (see FIG. C & D). WARNING-DO NOT REPLACE ANY ELECTRICAL COMPONENT for this Luminaire without consulting a qualified Electrician or Luminaire Manufacturer. * Consult factory for Remote LED driver ordering and installation. Black Wire White Wire Neutral (+) Wire DALUME R DALUME L EEMA I G H T I N G DRL11_RM - TEE BAR Ceiling Recessed Mount FIG. A 12" x 12" T-Bar spacing Luminaire Opening R LIGHTING GROUP LOS ANGELES, CA SAVE THESE INSTRUCTIONS INSTALL AND USE THIS LUMINAIRE FOLLOWING THE NATIONAL ELECTRICAL CODE, YOUR LOCAL ELECTRICAL CODE AND REGULATIONS. 1 PREPARATION: FIG. B 1). Read and understand instructions completely before installing this luminaire. If you are unfamiliar with electrical wiring have a qualified licensed electrician installs this luminaire. 2). Before proceeding the installation, be sure that the ceiling construction follows the proper requirements. 3). 12in x 12in T-Bar Framing is required, as specified in FIG. A. Framing clearance (ceiling) Opening must be 12" x 12" x 10" Height. CAUTION! NON-IC LUMINAIRES: Ceiling insulation must be kept a minimum of 3" away from the sides of the framing. No insulation allowed on the top. Install housing at a minimum of 1/2" away from combustible material such as sub-flooring or roofing. 2 INSTALLING POWER SUPPLY: Recessed Luminaire FIG. C NOTE: Ceiling Suspension Cables must be installed prior to Recessed Luminaire installation. 1). In order to be able to install the Recessed Luminiare into the Framing, pass Electrical Supply through Ceiling Opening and connect to Luminaire Electrical Box to make electrical connection (see FIG. E). 3 ELECTRICAL CONNECTIONS: 1). WARNING- Before starting the wire connections, disconnect the power by turning off the circuit breaker or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to prevent electrical shock. 2). This luminaire must be connected with supply wire rated at 90o C. Most dwellings built before 1985 have supply wire rated at 60o C; consult a qualified electrician before installing. 3). Connect the power source to the luminaire junction box. Connect the line (-) wire to the black wire of the power source, the neutral (+) wire to the white wire of the power source and connect the ground wire to the green ground wire of the power source using twist type wire connectors (by others) suitable for the size, type and number of wires; see wiring diagram (see FIG. E). 4). After completing the wiring (be sure the wires are placed within the electrical box), replace J-Box cover. FIG. D FINAL INSTALLATION (1x) 3/4" K.O. Suspension Cables FIG. E WIRING DIAGRAM POWER SUPPLY Ground Wire 1). Tilt Recessed Luminaire and insert it all away into the Frame in diagonal angle. Lens facing down (see FIG. B). 2). Let the Recessed Luminaire come down and rest on the Frame Flanges as shown in illustration (see FIG. C & D). NOTE: When Installing with Suspension Cables, access above ceiling is required (see FIG. D). T-BAR CEILING MOUNTED Ground Wire 4 INSTALLING RECESSED LUMINAIRE: Line (-) Wire WARNING-DO NOT REPLACE ANY ELECTRICAL COMPONENT for this Luminaire without consulting a qualified Electrician or Luminaire Manufacturer. * Consult factory for Remote LED driver ordering and installation. Black Wire White Wire Neutral (+) Wire DALUME R DALUME L I G H T I N G DRL11_SM - Ceiling / Wall Surface Mount - LIGHTING GROUP LOS ANGELES, CA SAVE THESE INSTRUCTIONS 1 PREPARATION: 4x Mounting Screw Surface Frame R INSTALL AND USE THIS LUMINAIRE FOLLOWING THE NATIONAL ELECTRICAL CODE, YOUR LOCAL ELECTRICAL CODE AND REGULATIONS. 4x Screw Anchor FIG. A 1). Read and understand instructions completely before installing this luminaire. If you are unfamiliar with electrical wiring have a qualified licensed electrician installs this luminaire. 2). Before proceeding the installation, be sure that the ceiling construction follows the proper requirements . 2 INSTALLING LUMINAIRE SURFACE FRAME: NOTE: Ceiling / Wall (sheet-rock) must be installed prior to Luminaire Surface Frame installation. 1). Choose desire location, place Surface Frame on mounting surface and trace the holes. 4 mounting holes minimum required (see FIG. A). 2). Insert Screw Anchors (by others) into sheet-rock openings. Make sure the Screw Anchors are flush with mounting surface and install the Surface Frame using Mounting Screws (by others) as shown (see FIG. A). 3). In order to be able to install the Surface Luminiare into the Frame, pass Electrical Supply through Frame and connect to Luminaire Electrical Box to make electrical connection (see FIG. E). Surface Luminaire FIG. B 4x Machine Screw FIG. C FIG. D FINAL INSTALLATION WALL MOUNTED FIG. E WIRING DIAGRAM Ground Wire Ground Wire 3 MAKE ELECTRICAL CONNECTIONS: 1). WARNING- Before starting the wire connections, disconnect the power by turning off the circuit breaker or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to prevent electrical shock. o 2). This luminaire must be connected with supply wire rated at 90 C. Most dwellings built before o 1985 have supply wire rated at 60 C; consult a qualified electrician before installing. 3). Connect the power supply to the Luminaire Junction Box. Connect the line (-) wire to the black wire of the power supply, the neutral (+) wire to the white wire of the power supply and connect the ground wire to the green ground wire of the power supply using twist type wire connectors (by others) suitable for the size, type and number of wires; see wiring diagram (see FIG. E). 4). After completing the wiring (be sure the wires are placed within the electrical box), replace J-Box cover. 4 INSTALLING SURFACE LUMINAIRE: CEILING MOUNTED POWER SUPPLY EEMA Line (-) Wire 1). Place Surface Luminaire into the Frame and install using the four Machine screws provided (see FIG. B & C). WARNING-DO NOT REPLACE ANY ELECTRICAL COMPONENT for this Luminaire without consulting a qualified Electrician or Luminaire Manufacturer. * Consult factory for Remote LED driver ordering and installation. Black Wire White Wire Neutral (+) Wire DALUME R