For Con-Tech Lighting 6" LED IC Rated Recessed Downlight: RA6LIC Series JOIST: 2" x 8" INSTALLATION PROCEDURES • Housing can be installed in direct contact with insulation. (Figure 1) • Install hanger bars to fixture; ensure end tab is facing outward. (Figure 2) • Extend bar hangers to fit between joists and position fixture temporarily by hammering nail on bars into the joists. Hangers should be level with bottom of the joists. • Use T-Bar slot in the bottom bars for suspended (T-Bar) ceilings, bending the tabs to hold T-Bar tightly. • Make all necessary electrical connections (See “Electrical Connection”). • When using 0-10V dimming drivers, Class I wiring (300V wiring inside conduit) is required. INSULATION CEILING MATERIAL Nail In Tabs ELECTRICAL CONNECTION: • Housing junction box contains two wires: a black (hot) and a white (neutral). Wires must be spliced to the current feed wires. ALWAYS SPLICE WHITE TO WHITE AND BLACK TO BLACK. • Insert wires carefully into junction box. Connect the green ground wire to the green grounding pigtail in junction box (Figure 3). Replace cover. • For Romex or 3-wire BX, flexible metal cable installations attach supply ground lead (green) to bare copper ground lead or ground screw in wiring box mounted on plaster frame. Local electrical codes should be consulted to determine acceptable installation: conduit, Romex or flexible metal cable. • For 700 Series Dimming, the 12D1 driver option can be dimmed with many standard 120V incandescent and electronic low voltage dimmers. White to White Black to Black TRIM AND LED MODULE INSTALLATION: • Remove protective cover from LED Module. • For decorative trim assemblies with separate trim ring, place ring on reflector prior to assembly. • Attach reflector to LED Module with (2) screws (Figure 4). For trim assemblies with lenses and/or two piece reflectors; complete the trim assembly by positioning the lens and lower reflector in place. • Make the LED Module electrical connection with the connectors (Figure 5). • Carefully route excess wire out of the way; align tab in conduit base to recess in heat-sink (Figure 5A) and snap into place making sure the tabs are engaged with the recessed grooves. (Figure 5B) • Push LED Module with assembled reflector through the hole in plaster frame until flush with ceiling. Spring clip tension can be adjusted by bending spring clips. Ground Wire Screws REPLACEMENT OF LED DRIVER: NOTE: LED Driver should be replaced by a qualified electrician. Turn off power at fuse or circuit breaker box before replacing the LED Driver. • Pull and drop the trim and LED Module from the frame. • Remove the conduit base from the LED Module by squeezing the sides with the tabs and pull apart (Figure 5). Disconnect the electrical connection. • Remove LED Driver/Bracket from the housing by unscrewing the (2) wing nuts (Figure 6). • Pull the LED Driver/Bracket assembly out of the housing and disconnect it from the line voltage input wiring and remove the driver assembly. • Reinstall Factory Approved LED Driver Assembly by reversing above procedure. IMPORTANT SAFETY INSTRUCTIONS: • Read all the instructions before installation. Save instructions for later use. • Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work. • Product must be grounded to avoid potential electric shock and any other potential hazards. • Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National Electrical Code and local codes. Use of accessory equipment is not recommended. • Installing contrary to instructions may cause unsafe conditions. • Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions. • Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation. • To avoid hazards to children, account for all parts and properly dispose of all packing materials. • Call the Technical Support department at Con-Tech Lighting with any installation questions: 847.559.5500. 1-847-559-5500 www.con-techlighting.com Tab A B Wing Nuts All specifications subject to change without notice. This document can be recycled. RA6LIC INST