NEMA 48 thru 213T Applications: Pumps, fans and other applications where only 50 hertz power is available. Features: CE certified. Windings tied each end at every slot for rigidity. Ball bearings, high temperature insulation, copper windings. Hp RPM 50 Hz. NEMA Frame Catalog Number List Price 1500 3000 56 56 48 56 56 56 56 56 56 56 145T 56 182T 184T 213T L3501-50 L3503-50 L3409-50 L3504-50 L3506-50 L3507-50 L3509-50 L3510-50 L3513-50 L3514-50 L3514T-50 L3515-50 L3605T-50 L3609T-50 L3708T-50 418 409 476 476 456 565 531 650 699 734 734 909 1,039 1,223 1,462 48 48 48 48 56 56 56 56 56 56 56 56 182T 184T 213T L1205-50 L1206-50 L1208-50 L1209-50 L1304-50 L1306-50 L1307-50 L1309-50 L1318-50 L1313-50 L1319-50 L1317-50 L1405T-50 L1408T-50 L1508T-50 309 376 340 472 428 414 529 436 645 612 744 815 865 934 1,462 Mult. Sym. “C” Dim. Aprx. Wt. (lb) Full Load Efficiency Voltage Full Load Amps 25 27 31 32 35 38 40 47 48 46 51 53 76 95 119 59 68 62 62 62 66 68 68 68 73 73 77 81 84.5 84 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 220 3.2 3.3 3.6 3.6 4.6 5 6.3 6.2 9 8 8 9.7 10 12.5 22 22 24 25 28 29 28 38 34 41 43 41 47 66 91 112 64.9 62 68 62 62 64 66 66 68 68 68 70 69 75.5 82.5 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 220 2.6 2.3 3.3 3.7 3.7 5.3 5 6 6.5 9.2 11.5 12 14 16 21.6 Notes (a) Definite Purpose Motors 1/3 thru 5 Hp Unit Handling Motors Single Phase, NEMA Frame, TEFC and ODP, Foot Mounted Brake Motors 50 Hertz Motors 2 3 5 1500 3000 1500 1500 1500 1 1 2 2 Open Drip Proof, IP22 1/3 1/2 3/4 1 1 1/2 2 3 5 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 1500 1500 K K K K K K K K K K K K L1 L1 L1 9.13 9.38 9.75 10.63 11.01 11.01 12.07 11.51 12.07 12.07 12.07 12.94 15.00 16.50 16.32 IEC Frame Motors 1 1/2 2 2 2 2 2 50 Hertz Motors 1 3000 1500 3000 1500 3000 1 Inverter/Vector Motors & Controls 3/4 1500 11.34 11.35 12.22 12.84 12.23 13.25 13.23 14.12 14.11 14.13 14.18 14.11 16.56 18.06 17.89 DC Motors and Controls 1/2 K K K K K K K K K K L1 K L1 L1 L1 200 & 575 Volt Motors Totally Enclosed Fan Cooled, IP54 1/3 (a) See notes on inside back flap. Gearmotors and Gear Products Soft Starters IP22 = Open Drip Proof, IP54 = Totally Enclosed Fan Cooled. All motors listed above are specifically designed for operation with 50 Hz. power. ­189 Definite Purpose Motors 50 Hertz Motors Unit Handling Motors Three Phase, NEMA Frame, TEFC and ODP, Foot Mounted 1/2 thru 60 Hp NEMA 56 thru 364T Applications: Pumps, fans and other applications where only 50 hertz power is available. Features: CE certified. Windings tied each end at every slot for rigidity. Ball bearings, high temperature insulation, copper windings. Brake Motors Hp RPM 50 Hz. NEMA Frame Catalog Number List Price Mult. Sym. “C” Dim. Aprx. Wt. (lb) Full Load Efficiency Voltage Full Load Amps 26 25 32 27 33 37 39 44 46 66 71 76 96 113 130 160 158 245 305 397 417 554 614 904 73 75.5 75.5 78.5 80 80 81.5 81.5 82.8 84 85 86 87.5 87.5 87.7 88.5 89.5 90.2 91.2 91.2 91.6 92.3 92.7 94.1 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 400 400 400 400 400 400 400 400 400 400 400 1 1.4 1.8 1.7 1.8 2.4 2.5 3 3.4 4.2 4.9 6.6 7.5 10.7 11.2 13.8 14.7 22 28 35 42 56 67 80.5 26 26 20 20 25 32 58 92 105 117 187 235 73 70 80 81 81.5 82.8 85 87.5 87.7 88.7 89.8 90.6 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 400 400 400 400 1 1.9 1.8 1.8 2.5 3.4 4.9 7.5 11.5 15.1 21.4 28 Notes (a) Totally Enclosed Fan Cooled, IP54 200 & 575 Volt Motors 15 20 25 30 40 50 60 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 1500 1500 1500 1500 1500 1500 1500 56 56 56 56 143T 143T 145T 145T 145T 182T 182T 184T 184T 213T 213T 215T 215T 254T 256T 284T 286T 324T 326T 364T M3538-57 M3541-57 M3542-57 M3545-57 M3546T-57 M3550T-57 M3554T-57 M3555T-57 M3558T-57 M3610T-57 M3611T-57 M3613T-57 M3615T-57 M3709T-58 M3710T-58 M3711T-58 M3714T-58 M2333T-58 M2334T-58 M4103T-58 M4104T-58 M4110T-58 M4115T-58 M4314T-58 446 446 477 543 555 630 565 692 596 882 700 1,014 808 1,493 1,027 1,563 1,249 2,193 2,646 3,725 4,403 5,759 6,252 8,129 1/2 3/4 1500 1500 1 1500 1 1/2 2 3 5 7 1/2 10 15 20 1500 1500 1500 1500 1500 1500 1500 1500 56 56 56 143T 145T 145T 182T 184T 213T 215T 254T 256T M3108-57 M3112-57 M3116-57 M3116T-57 M3154T-57 M3157T-57 M3211T-57 M3218T-57 M3311T-58 M3313T-58 M2513T-58 M2515T-58 393 437 494 497 528 543 621 687 972 1,189 1,797 2,314 1/2 3/4 1 1 1/2 IEC Frame Motors 2 3 5 7 1/2 50 Hertz Motors Inverter/Vector Motors & Controls DC Motors and Controls Soft Starters Gearmotors and Gear Products ­190 10 K K K K L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 11.35 11.35 12.85 11.35 12.31 12.31 13.31 13.31 14.19 16.52 16.54 16.54 18.04 17.89 19.01 19.76 19.76 21.07 23.35 27.76 27.76 30.28 30.28 33.44 Open Drip Proof, IP22 K K K L1 L1 L1 L1 L1 L1 L1 L1 L1 10.12 10.12 11.07 11.12 12.13 13.00 15.00 16.50 16.32 17.45 20.51 21.69 (a) See notes on inside back flap. IP22 = Open Drip Proof, IP54 = Totally Enclosed Fan Cooled. All motors listed above are specifically designed for operation with 50 Hz. power. Three phase, 50 Hz. motors shown in this catalog are suitable for use on 400 volt or 415 volt 50 Hz. power supplies. ■ Cast Iron Frame NEMA 56C thru 145TC Applications: Pumps, fans, gear reducers, conveyors and many other applications with 50 Hz power supply. Features: CE certified. Heavy gauge steel frame construction, pressure-cast aluminum endplates with machined steel bearing inserts for extended bearing life. Hp RPM 50 Hz. NEMA Frame 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 56C 56C 56C 56C 56C 56C 56C 56C 56C 56C Catalog Number List Price Mult. Sym. “C” Dim. Aprx. Wt. (lb) Full Load Efficiency Voltage Full Load Amps 17 25 31 35 39 40 47 48 51 52 59 68 62 62 66 68 68 68 73 77 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 110/220 3.2 3.3 3.6 4.6 5 6.3 6.2 9 8 9.7 20 21 22 25 26 32 26 35 34 36 38 44 43 46 64 68 72 73 75.5 75.5 78.5 80 80 80 81.5 81.5 81.5 82.8 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 0.7 1 1.1 1 1.4 1.8 1.7 1.8 1.8 2.4 2.5 3 3 3.4 Notes (a) Definite Purpose Motors 1/4 thru 2 Hp Unit Handling Motors Single and Three Phase, NEMA Frame, TEFC, C-Face, Footless Brake Motors 50 Hertz Motors 1 1/2 2 11.35 11.35 12.85 12.25 13.25 13.25 14.12 14.12 14.12 14.12 Three Phase, IP54 1/4 1/3 1/2 3/4 1 1 1/2 2 1500 1500 3000 1500 3000 1500 3000 1500 3000 1500 3000 1500 56C 56C 56C 56C 56C 56C 56C 56C 143TC 143TC 145TC 56C 143TC 145TC KM3454-57 VM3534-57 VM3537-57 VM3538-57 VM3541-57 VM3542-57 VM3545-57 VM3546-57 VM3546T-57 VM3550T-57 VM3554T-57 VM3555-57 VM3555T-57 VM3558T-57 361 408 443 477 462 512 548 543 543 596 564 592 651 598 K K K K K K K K L1 L1 L1 K L1 L1 11.35 11.35 11.35 11.35 11.35 12.85 11.35 12.23 12.29 12.29 13.29 13.23 13.29 14.17 1 1 1 IEC Frame Motors 1 K K K K K K K K K K 50 Hertz Motors 3/4 459 416 532 480 630 564 721 726 815 921 Inverter/Vector Motors & Controls 1/2 VL3501-50 VL3503-50 VL3504-50 VL3506-50 VL3507-50 VL3509-50 VL3510-50 VL3513-50 VL3514-50 VL3515-50 200 & 575 Volt Motors Single Phase, IP54 1/3 Soft Starters Gearmotors and Gear Products IP54 = Totally Enclosed Fan Cooled. All motors listed above are specifically designed for operation with 50 Hz. power. Three phase, 50 Hz. motors shown in this catalog are suitable for use on 400 volt or 415 volt 50 Hz. power supplies. DC Motors and Controls (a) See notes on inside back flap. ­191 Definite Purpose Motors 50 Hertz Motors Unit Handling Motors Single and Three Phase, NEMA Frame, Explosion Proof, C-Face, Foot Mounted 1/3 thru 2 Hp Applications: Ideal for use on pumps, blowers, valves, and gearboxes where hazardous fumes and dust are present requiring Div 1 UL listed and/or CSA approved enclosures. Brake Motors Features: UL & CSA approved for Class I, Group D; Class I, Group D, Class II, Group F & G. Totally enclosed heavy gauge steel construction with locked drive end bearing. Corrosion resistant epoxy finish. Single or Three Phase design. 1.0 Service Factor. Fixed speed sine wave operation only. No Drip Cover. 200 & 575 Volt Motors IEC Frame Motors Hp RPM NEMA Frame Catalog Number 1/3 1/2 3/4 1 2 1500 1500 1500 1500 1500 56C 56C 56C 56C 182TC CL5001A-50 CL5004A-50 CL5007A-50 CL5023-50 CL5027T-50 ➁ ➁ ➁ ➀ ➀ T3C T3C T4 T3C T2C 1/2 3/4 1500 1500 3000 1500 3000 1500 3000 1500 56C 56C 56C 56C 143TC 143TC 145TC 145TC CM7006-57 CM7010-57 CM7013-57 CM7014-57 CM7018T-57 CM7034T-57 CM7071T-57 CM7037T-57 ➁ ➁ ➁ ➁ ➁ ➁ ➁ ➁ T3C T3C T3C T3C T3C T3C T3C T3C 1 1 1/2 50 Hertz Motors 2 NEMA 56C thru 182TC XP Temp Cls/Grp Code List Price Mult. Sym. Single Phase 911 K 912 K 1,061 K 1,122 K 2,485 L1 Three Phase 994 K 1,017 K 1,028 K 1,087 K 1,169 L1 1,198 L1 1,209 L1 1,293 L1 “C” Dim. Aprx. Full Load Wt. (lb) Efficiency Voltage Full Load Notes (a) Amps 14.22 15.22 15.17 16.05 20.36 35 45 52 56 121 59.5 62 70 68 77 110/220 110/220 110/220 110/220 110/220 2.6 3.6 4.8 6.2 11.5 2 2 2 2 2 14.22 15.22 14.22 15.22 14.36 15.23 15.23 16.10 36 42 34 45 47 49 50 59 73 75.5 78.5 74 80 81.5 78.5 84 230/400 230/400 230/400 230/400 230/400 230/400 230/400 230/400 1 1.7 1.7 2 2.4 2.5 3.2 3.4 2 2 2 2 2 (a) See notes on inside back flap. ➀ = Class I, Group D; ➁ = Class I, Group D, Class II, Group F & G Inverter/Vector Motors & Controls DC Motors and Controls Soft Starters Gearmotors and Gear Products ­192 Caution: Explosion-proof motors have a tight fit between mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of moisture inside the motors due to condensation. Care should be used when selecting an explosion-proof motor, especially when installed outdoors and on intermittent duty. These explosion proof motors are not suitable for use with adjustable speed drives. Inverter Duty explosion proof motors must be used. See pages 88-90.