ISI - Inverter Systems, Inc.

advertisement
ISI - ABC
“ALL BASES COVERED” INVERTER
Mini Emergency Power Source for LED, Incandescent, and Fluorescent
Cover the Bases
A pure sine wave inverter delivers a waveform
identical to the output of a utility, in some cases
even superior to it because of reduced THD (total
harmonic distortion). By replicating utility power,
pure sine wave inverters guarantee compatibility
for all LED, fluorescent, and incandescent loads.
Three Models to Choose From
ABC Mini
The ABC Mini packs exceptional functionality into a
compact housing, available in 100, 125, 200 and 250
watt capacities. This unit is LED compatible and
features code-compliant self-testing and self
diagnostic capabilities.
Fully Featured
ISI’s ABC Mini is packed with cutting edge features that include three distinct output types, UL924 approved self-testing and self-diagnostics,
battery low level indication, power-up diagnostics
to check for common wiring errors and 16 distinct
major and minor alarms just to name a few. Coupled with options like infrared receiver for remote
testing, time delay for HID applications and a
sonic alarm, the ABC Mini is unlike any inverter
in its class.
Unlike self-contained battery packs which install
within the luminaires, the ABC is installed remotely for ease of maintenance, testing and battery
longevity. Full light output also results in higher
illumination levels and increased spacing.
ABC Mini Recessed
Delivers all the features offered by the ABC Mini 100
and 125 can be installed in areas where low-profile
functionality is required.
ISI
ABC Mini T-Line
Cover them all!
The ABC Mini T-Line matches the Mini 100 and 125
on features and has been specifically designed for use
with T-bar ceilings—blending in beautifully.
Don’t take chances! Pure sine wave technology is
100% LED compatible; modified sine wave technology is not.
www.invertersystemsinc.com
329 Otter Street, Bristol, PA 19007 • Tele: (215) 788-8870 • Fax: (215) 788-8873
ISI
ISI - ABC
“ALL BASES COVERED” INVERTER
Mini Emergency Power Source for LED, Incandescent, and Fluorescent
Specifications
OUTPUT
Voltage: 120 or 277 VAC model dependant
INPUT
Voltage: 120 or 277 VAC Model dependant
Current: 1.4A(120V), 0.6A(277V) for 100/125 Watt Model
2.7A(120V), 1.2(277V) for 200/250 Watt Model
Current: 0.84A (120V), 0.36A (277V) for 100 Watt
1.04A (120V), 0.45A (277V) for 125 Watt
1.67A (120V), 0.73A (277V) for 200 Watt
2.08A (120V), 0.9A (277V) for 250 Watt
Frequency: 60Hz +/- 2 Hz
Frequency: 60Hz +/- 0.02 Hz crystal controlled during
emergency mode
Power Factor: 0.5 Lead to 0.5 Lag
Overload: 110 per cent will generate overload fault
Transfer Time: 50 msec
BATTERY
Type: Valve-Regulated Sealed Lead Calcium,
upgrade options available
Output Distortion: Less than 3% THD
Crest Factor: 2.5 for 125 and 250W model
Charger: 3 rate with Temperature Compensation
Load Power Factor: 0.5 lead to 0.5 lag
Recharge Time: 24 Hour recharge standard
Output Types: Normally On, Normally Off and Switched
Maintained Outputs
Runtime: 90 Minutes, initial margin of 125
percent at 25 deg. C
ENVIRONMENTAL
Operating Temp: 20 to 30 degrees centigrade
Storage Temp: -20 to 70 degrees Centigrade (Batteries)
Relative Humidity: <95 % non-condensing
Protection: Automatic Low Voltage Disconnect
(LVD) set at 1.67 VPC
DC Voltage: 12/24 VDC Nominal, 2.27 VPC .oat,
temperature compensated
PHYSICAL
Cooling: Natural convection-No fans
Cabinet: NEMA Type 1 enclosure, 18 ga, powder coated CRS
Ordering Guide
ABC-125-120 ABC-250-120
DC Current: 12.5A nominal for 125/250 Watt model
respectively
250W
125W
125 watt, 120/120 VAC
250 watt, 120/120 VAC
ABC-125-277
ABC-250-277
125 watt, 277/277 VAC
250 watt, 277/277 VAC
*Replace 100 or 200 in place of the 125 and 250 for smaller capacities
Options
AA
CL
IR
RT
TLRT
RE
TB
TD
2H
UP
Audible Alarm
Listed to CAS C22.2 No. 141-10
Infrared Receiver for remote testing
Remote test switch and monitor
Infrared remote hand held transmitter
Recessed frame for wall recessed (100W only)
T-bar mount housing (100W only)
15 minute time delay
Two hour run time
Pre-shipped, less battery
WARRANTY:
Electronics Assembly
Inverter Systems, Inc. warrants the ISI-ABC electronics assembly (except batteries) against defects in material and
workmanship for a period of three years from date of shipment. Inverter Systems, Inc. will either repair or replace
any properly installed ISI-ABC system which fails under normal operating conditions provided that it is returned to
the factory, transportation prepaid, and our inspection
determines it to be defective under the terms of this warranty.
The warranty covers only equipment other than batteries manufactured by Inverter Systems, Inc.
and does not extend to transportation, installation or replacement charges, nor does it apply to any
other equipment of another manufacturer used in conjunction with ISI equipment. No other warranty expressed or
implied exists beyond that included in this statement.
Battery Warranty
Sealed lead calcium batteries carry a 1 year full, 9 year pro-rated limited warranty.
Important note: Battery warranty is limited to certain environmental, operational and installation limitations.
www.invertersystemsinc.com
329 Otter Street, Bristol, PA 19007 • Tele: (215) 788-8870 • Fax: (215) 788-8873
IS
ISII