ISI - ABC “ALL BASES COVERED” INVERTER Mini Emergency Power Source for LED, Incandescent, and Fluorescent Cover the Bases A pure sine wave inverter delivers a waveform identical to the output of a utility, in some cases even superior to it because of reduced THD (total harmonic distortion). By replicating utility power, pure sine wave inverters guarantee compatibility for all LED, fluorescent, and incandescent loads. Three Models to Choose From ABC Mini The ABC Mini packs exceptional functionality into a compact housing, available in 100, 125, 200 and 250 watt capacities. This unit is LED compatible and features code-compliant self-testing and self diagnostic capabilities. Fully Featured ISI’s ABC Mini is packed with cutting edge features that include three distinct output types, UL924 approved self-testing and self-diagnostics, battery low level indication, power-up diagnostics to check for common wiring errors and 16 distinct major and minor alarms just to name a few. Coupled with options like infrared receiver for remote testing, time delay for HID applications and a sonic alarm, the ABC Mini is unlike any inverter in its class. Unlike self-contained battery packs which install within the luminaires, the ABC is installed remotely for ease of maintenance, testing and battery longevity. Full light output also results in higher illumination levels and increased spacing. ABC Mini Recessed Delivers all the features offered by the ABC Mini 100 and 125 can be installed in areas where low-profile functionality is required. ISI ABC Mini T-Line Cover them all! The ABC Mini T-Line matches the Mini 100 and 125 on features and has been specifically designed for use with T-bar ceilings—blending in beautifully. Don’t take chances! Pure sine wave technology is 100% LED compatible; modified sine wave technology is not. www.invertersystemsinc.com 329 Otter Street, Bristol, PA 19007 • Tele: (215) 788-8870 • Fax: (215) 788-8873 ISI ISI - ABC “ALL BASES COVERED” INVERTER Mini Emergency Power Source for LED, Incandescent, and Fluorescent Specifications OUTPUT Voltage: 120 or 277 VAC model dependant INPUT Voltage: 120 or 277 VAC Model dependant Current: 1.4A(120V), 0.6A(277V) for 100/125 Watt Model 2.7A(120V), 1.2(277V) for 200/250 Watt Model Current: 0.84A (120V), 0.36A (277V) for 100 Watt 1.04A (120V), 0.45A (277V) for 125 Watt 1.67A (120V), 0.73A (277V) for 200 Watt 2.08A (120V), 0.9A (277V) for 250 Watt Frequency: 60Hz +/- 2 Hz Frequency: 60Hz +/- 0.02 Hz crystal controlled during emergency mode Power Factor: 0.5 Lead to 0.5 Lag Overload: 110 per cent will generate overload fault Transfer Time: 50 msec BATTERY Type: Valve-Regulated Sealed Lead Calcium, upgrade options available Output Distortion: Less than 3% THD Crest Factor: 2.5 for 125 and 250W model Charger: 3 rate with Temperature Compensation Load Power Factor: 0.5 lead to 0.5 lag Recharge Time: 24 Hour recharge standard Output Types: Normally On, Normally Off and Switched Maintained Outputs Runtime: 90 Minutes, initial margin of 125 percent at 25 deg. C ENVIRONMENTAL Operating Temp: 20 to 30 degrees centigrade Storage Temp: -20 to 70 degrees Centigrade (Batteries) Relative Humidity: <95 % non-condensing Protection: Automatic Low Voltage Disconnect (LVD) set at 1.67 VPC DC Voltage: 12/24 VDC Nominal, 2.27 VPC .oat, temperature compensated PHYSICAL Cooling: Natural convection-No fans Cabinet: NEMA Type 1 enclosure, 18 ga, powder coated CRS Ordering Guide ABC-125-120 ABC-250-120 DC Current: 12.5A nominal for 125/250 Watt model respectively 250W 125W 125 watt, 120/120 VAC 250 watt, 120/120 VAC ABC-125-277 ABC-250-277 125 watt, 277/277 VAC 250 watt, 277/277 VAC *Replace 100 or 200 in place of the 125 and 250 for smaller capacities Options AA CL IR RT TLRT RE TB TD 2H UP Audible Alarm Listed to CAS C22.2 No. 141-10 Infrared Receiver for remote testing Remote test switch and monitor Infrared remote hand held transmitter Recessed frame for wall recessed (100W only) T-bar mount housing (100W only) 15 minute time delay Two hour run time Pre-shipped, less battery WARRANTY: Electronics Assembly Inverter Systems, Inc. warrants the ISI-ABC electronics assembly (except batteries) against defects in material and workmanship for a period of three years from date of shipment. Inverter Systems, Inc. will either repair or replace any properly installed ISI-ABC system which fails under normal operating conditions provided that it is returned to the factory, transportation prepaid, and our inspection determines it to be defective under the terms of this warranty. The warranty covers only equipment other than batteries manufactured by Inverter Systems, Inc. and does not extend to transportation, installation or replacement charges, nor does it apply to any other equipment of another manufacturer used in conjunction with ISI equipment. No other warranty expressed or implied exists beyond that included in this statement. Battery Warranty Sealed lead calcium batteries carry a 1 year full, 9 year pro-rated limited warranty. Important note: Battery warranty is limited to certain environmental, operational and installation limitations. www.invertersystemsinc.com 329 Otter Street, Bristol, PA 19007 • Tele: (215) 788-8870 • Fax: (215) 788-8873 IS ISII