Model VLF-90CM AC Hipot/Burner 0-90 kVac, with 0.1 to 0.02 Hz Output Frequency Control Layout �������������������� �������� ���������������� ���������� ���������������� �������� ���������������� ���������� ���������������� �������� ��������������� �������� ����������������� ��������� ����������������� ��������� ����������������� VLF-4022CM AT LAST: A Powerful VLF AC Testing Solution for medium voltage, 44, 69 and 115 kV class XLPE, PE, EPR, RL and PILC cables, splices, transition joints and T joints. The High Voltage, INC. VLF series of AC Hipots finally enables utilities and industry to economically AC field test cables and electrical apparatus instead of DC testing (*VLF - Very Low Frequency). VLF-25CM What is VLF? A VLF unit is an AC hipot with a 0.1 Hz or lower output frequency, used for AC testing high capacitance loads. At 0.1 Hz, it requires 600 times less power to test a cable, generator, etc., than at 60 Hz and 500 times less power than at 50 Hz. A VLF test is a go/no-go stress test. The load either holds the test voltage or breaks down. It is the surest and easiest way to expose defects in cables and generators. Why VLF Hipot? “Because DC testing can be harmful to cables and deleteriously cause faults within the solid dielectric insulation of cables!” VLF testing exposes cable defects while not harming good insulation. A VLF test can detect cable defects at a much lower voltage than a DC hipot/ proof test. Also, voltage transients are much smaller with a VLF AC hipot test during cable failure or flashover than with a DC hipot/proof test. There are no travelling waves generated during VLF testing. The VLF AC hipot also burns, breaks-down and conditions a cable fault much quicker than conventional DC burners. Therefore, fault locating time is reduced with existing thumpers and radar devices. HIGH VOLTAGE, INC. 31 Rt. 7A: P.O. Box 408 • Copake, NY 12516 • (518) 329-3275 • Fax: (518) 329-3271 E-Mail: sales@hvinc.com • Web: www.hvinc.com High Voltage, Inc. designs and manufactures high voltage test equipment for utility and industrial applications. Also available are Very Low Frequency (VLF) high voltage AC test sets, DC power packs, AC and DC instrumented test sets, cable fault locators and other products. Specifications, sizes, weights and features may vary slightly in the interest of continuous product improvement. Model VLF-90CM AC Hipot/Burner Description The VLF-90CM is a continuously adjustable 0-90 kilovolt continuous duty AC hipot with a 0.1/0.05/0.02 Hz sinusoidal output. The waveshape is independent of capacitive loading and can test cables up to 25,000 feet in length. The two piece design is suitable for test van or trolley mounting and operates from a 230 volt electrical service. Control Layout Meets NEW IEEE 400.2 Standard ���������������������������������� • Smallest, lightest weight for a 90 kV peak AC-VLF Hipot available with the largest test load ratings • Two-piece portability • Simple and easy operation Controls are elementary: Power ON and Raise/Lower switches, HV ON and OFF, Fault Reset, and Start Timer pushbuttons, single range 100kV peak kilovoltmeter and 100mA peak charging current meter. In addition, a capacitance measurement circuit for pre-determining cable/load capacitance is provided. For waveform viewing, a BNC output jack for oscilloscope connection is included. Specifications Input: 230 V, 50/60 Hz, 20A peak, 15A average Output: Sinusoidal, 0-90 kVac peak, 0.1/0.05/0.02 Hz frequency Continuous duty. 20 ft. shielded x-ray output cable Load: .55 �F (approx 5,000 ft of cable) @ 0.1 Hz 1.1 �F (approx 10,000 ft of cable) @ 0.05 Hz 2.75 �F (approx 25,000 ft of cable) @ 0.02 Hz Metering: Voltmeter: 0-100 kVac peak Current Meter: 0 – 100 mA peak Load capacitance: 0–6 microfarads Sizes: Control: 25��w x 13��d x 16��h, 635 mm w x 330 mm d x 406 mm h HV Tank: 15��w x 21��d x 27��h, 381 mm w x 533 mm d x 686 mm h Weights: Control: 75 lbs. (34 kg) HV Tank: 293 lbs. (133 kg) • 230Vac, 50/60Hz input line required • The VLF AC Hipot does NOT generate harmful voids in the insulation through treeing • Harmful space charges are NOT injected into the dielectric during testing • A true-sinusoidal output voltage waveform is used • No traveling waves are generated during testing • Waveshape independent of capacitive loading between 0.01�f and maximum load ���������������������������� • Rotating machinery-IEEE-433 • Shielded power cable-IEEE-400.2 • Capacitors • Full reel cable • Bushings & insulators • Transformers HIGH VOLTAGE, INC. 31 Rt. 7A: P.O. Box 408 • Copake, NY 12516 • (518) 329-3275 • Fax: (518) 329-3271 E-Mail: sales@hvinc.com • Web: www.hvinc.com High Voltage, Inc. designs and manufactures high voltage test equipment for utility and industrial applications. Also available are Very Low Frequency (VLF) high voltage AC test sets, DC power packs, AC and DC instrumented test sets, cable fault locators and other products. Specifications, sizes, weights and features may vary slightly in the interest of continuous product improvement. 500VLF90/11/04