Master Switch - Ashdown

advertisement
B-Safe
The
Master Switch
The B-Safe series (ACX3493HD &
ACX3492HD) are designed to fulfil the duties
of a battery master switch, connecting and
disconnecting a vehicles batteries from
it’s electrical systems. The ACX3492HD is
suited to applications that require switching
of both positive and negative, where the
ACX3493HD is positive isolation only.
Safe working voltages for both units are from
9 to 32 Volt, and the unit will automatically
adapt to the systems voltage (12 or 24V).
Each unit is rated at 300 amps continuous
per contact, making 600 amps and a peak
rating of 1500 amps for 5 seconds.
The B-Safe units not only isolate batteries
through the mechanical handle, but can
control connection and disconnection
through external means including, rollover
protection inputs, emergency stop push
button signals, low voltage monitoring and
the local activation button also providing
fault diagnosis through flashing LED codes.
Other internal and external signals include
positive and negative supply for vehicles
ECM and field isolation control.
The B-Safe units are a lighter, more compact
unit compared to other product on the
market, and will provide a base for your
vehicles future isolation requirements.
4
10
9
5
2
8
7
6
3
1
ID
Description
Qty Note
1
B-Safe Main Body
1
2
Protection Cover
1
3
Support for Padlocks
1
4
Handle
1
For safety reasons, to be inserted and removed
only in off position.
5
Fixing Inserts
4
They can be orientated to match different
interaxis distance.
6
Plain Washer
4
7
Spring Washer
4
8
M10 Nut
4
9
Curve Washer
2
10
M4 Screw
2
Isolating barries are removeable to adapt cab
orientation.
Specifications
Features
• Ex Certification
• IROS (and other rollover protection systems)
compatibility and testing simulation
• IP69K body protection
• Low Voltage Monitoring and threshold deactivation
• ECM supply and delayed deactivation from B-Safe
shutdown
• Direct Lucas replacement with matching mounting pattern
• Lockout function
• LED troubleshooting illumination and self diagnosis
• Stand alone function ability without external inputs
• Field Isolation and D+ deactivation
Weight
2.6kg
Dimensions
150D x 126W x 166H (mm)
Mounting Centres
127L x 104W (mm) M8
Protection class
IP69K (B-Safe body)
IP54 (Contact protection)
EX Compliant
(ll2GExibllCT6)
CE Compliant
0080
Temperature range
- 40 to 70°C
Vibration rating
10G to ICE 60068-2-6
Main Terminal size
M10
Working Voltage
(auto adapt 9 - 32 Volt)
Continuous amp rating
2 x 300A contacts (@23ºC)
Peak amp rating
1500A for 5 sec (@23ºC)
Lockout option
3 lockout points standard
Cable protection
Top cover provides cable entry protection
Copyright © 2013 Ashdown-Ingram ABN 97 097 993 283
Replacing a Lucas Master Switch with a B-Safe (ACX3492HD & ACX3493HD)
Lucas Master Switch
B-Safe Master Switch
Circuit
Description
Lucas
Master Switch
B-Safe
Master Switch
B-Safe
Additional Notes
Battery Positive
TERMINAL 7
BAT +
Connect Battery Positive On "Bat +" Stud and Load Positive On
"Load+" Stud.
Battery Negative
TERMINAL 9
BAT
For Double Positive Versions, 2nd Battery Positive Cable On "Bat" Stud
and 2nd Load Positive On "Load" Stud
Vehicle Positive
TERMINAL 8
LOAD +
For Bipolar Versions, Battery Negative Cable On "Bat" Stud and Load
Negative On "Load" Stud
Vehicle Negative
TERMINAL 10
LOAD
PIN 5
N/A
PIN 6
N/A
PIN 2
C1:7
PIN 4
C1:3
Auxiliary Contacts
External Shutdown
(Pos Switching)
C1:7
The B-Safe Units have no Auxiliary Contacts Internally. To Replicate.
A Relay Can Be Switched From C1:1 and C1:2 (Note, this circuit has a
1Amp rating)
Remote Off Control Switch, Command Active when at Battery Positive
Remote On Control Switch, Command Active when at Battery Positive
C1:4
External Shutdown
(Neg Switching *Iros)
PIN 2
C2:1
PIN 4
C2:2
PIN 1
C1:5
True field isolation (American style) is recommended. If European style
field isolation is used through D+ on the alternator. Only C1:5 connection
is required. Ensure the alternator ceases charging during testing.
PIN 3
C1:6
C1:5 (field isolation will occur ~140 msec before main circuit opens)
Field Isolation
This is a Negative Switching Circuit. C2:1 is Neg Supply Output for Iros
or other Rollover Device (1A Continious Rating)
When main bridges are closed. C1:5 is (internally) connected to C1;6.
When main bridges are open, C1:5 is (internally) connected to battery
negative, which on Pos/Pos versions comes internally from C2:6 and
which on bipolar versions comes internally from “Bat” stud.
Use 10A external fuse on field isolation circuit
Vehicle Pos Output
PIN 12
C1:2
C1:2 Max continuous output is 1.5A
Vehicle Neg Output
PIN 11
C1:1
C1:1 Max continuous output is 1.5A
C:1 is Connector One, C:2 is Connector Two.
Copyright © 2013 Ashdown-Ingram ABN 97 097 993 283
B-Safe Key Circuits
2
3
1
4
7
5
6
3
2
C1
C2
(RED)
1
4
5
7
6
C1-1 Supply Ground Output for Ecm, Max Continuous Rating 1.5A
C1-2 Supply Positive Output for Ecm, Max Continuous Rating 1.5A
C1-3 Input for Remote Off Control Command, Momentry Activation
C1-4 Input for Remote On Control Command, Momentry Activation
C1-5 Field Winding Isolation, will occur approximently 140msec before Main Circuit Opens
C1-6 Field Winding Isolation (Please Ensure True Isolation when Testing)
C1-7 Output for Remote Control Command (C1-3, C1-4)
C2-1 Supply Ground for Roll Over Device, Max Continuous Rating 100mA
C2-2 B-Safe Input for Emergency Off Command (Roll Over Device) Momentry Activation, Multiple Switches must be
Active Low and, when Inactive Open State
C2-3 Supply Positive Output for Roll Over Device, Max Continious Rating 100mA
C2-4Input for Test / Diagnosis Lamp for Roll Over System (Connect to Roll Over Device Warning Light Output)
C2-5 Output for Test Activation (Connect to Roll Over Device Test Input)
C2-6 Supply Ground for Double Positive Versions (Pin not included on ACX3492HD)
C2-7Input Disabling LVM (Low Voltage Monitoring) and Electrical Switch-Off Triggered by handle
(Recommended to use Ignition Feed here). Do Not Use Permanent Postive, This Will Prevent Handle Activated
Switching. More Details are Listed in the Product Manual.
LVM function (Low Voltage Monitoring)
This function automatically opens the main contact in the case of low battery power.
This function must be activated during the installation if requested.
To activate:
• Handle in ready
• Main contact open
• Turn the handle from Ready to Off and within one second press and hold the local On button for 10 seconds
• There will be blinking from the local On button to confirm LVM is activated.
Turn handle from Off to Ready.
Voltage thresholds are;
• In the case of 24 volt systems, the B-Safe will detect low battery with a voltage below 21 volt.
• In the case of 12 volt systems, the B-Safe will detect low battery with a voltage below 9 volt.
Copyright © 2013 Ashdown-Ingram ABN 97 097 993 283
Branch Listing
HEAD OFFICE
Cairns
Molendinar
5 Viola Place, Export Park
Brisbane Airport
QLD 4007
P: 07 3358 9400
102 Lyons Street
Cairns 4870
P: 07 4031 3816
cairns@ashdown-ingram.com.au
Unit 2, 26 Expo Court
Ashmore 4214
P: 07 5528 1266
molendinar@ashdown-ingram.com.au
QUEENSLAND
Emerald
Mt Isa
Archerfield
Unit 2, 124 Beatty Road
Archerfield 4108
P: 07 3277 8633
archerfield@ashdown-ingram.com.au
Bundaberg
Unit 16, 96 Mount Perry Rd,
North Bundaberg 4670
P: 07 5522 1377
bundaberg@ashdown-ingram.com.au
Burleigh
Unit 3, 2 John Duncan Court
Burleigh Heads 4220
P: 07 5522 1377
burleigh@ashdown-ingram.com.au
Caboolture
Unit 2, 84-86 Learjet Drive
Caboolture QLD 4510
P: 07 5495 1311
caboolture@ashdown-ingram.com.au
55 Industrial Drive
Emerald 4720
P: 07 4987 4388
emerald@ashdown-ingram.com.au
Gladstone
116 Hanson Road
Gladstone 4680
P: 07 4972 1677
gladstone@ashdown-ingram.com.au
Ipswich
Unit 3B, 2 Pound St
West Ipswich 4305
P: 07 3202 1309
ipswich@ashdown-ingram.com.au
15 Isa Street
Mt Isa 4825
P: 07 4743 1633
mtisa@ashdown-ingram.com.au
Rockhampton
223 Denison Street
Rockhampton 4700
P: 07 4921 3799
rockhampton@ashdown-ingram.com.au
Springwood
44 Parramatta Road
Underwood 4119
P: 07 3208 4244
springwood@ashdown-ingram.com.au
Mackay
Sunshine Coast
8 Platinum Court
Mackay 4740
P: 07 4952 3172
mackay@ashdown-ingram.com.au
sunshinecoast@ashdown-ingram.com.au
Copyright © 2013 Ashdown-Ingram ABN 97 097 993 283
Unit 3, 18 Technology Drive
Warana 4575
P: 07 5493 9022
Toowoomba
Launceston
117 Galvin Street
South Launceston 7249
P: 03 6344 7042
launceston@ashdown-ingram.com.au
Wollongong
Unit 2, 101 Mort Street
Toowoomba 4350
P: 07 4632 9384
toowoomba@ashdown-ingram.com.au
Townsville
NORTHERN TERRITORY
VICTORIA
Darwin
Bendigo
502-508 Woolcock Street
Townsville 4814
P: 07 4728 6222
townsville@ashdown-ingram.com.au
Virginia
2095 Sandgate Road
(Off Radley Street)
Virginia 4014
P: 07 3633 0309
virginia@ashdown-ingram.com.au
WESTERN AUSTRALIA
Bunbury
8 Smokebush Drive
Bunbury 6230
P: 08 9725 6734
bunbury@ashdown-ingram.com.au
Geraldton
319 Place Road
Webberton 6230
P: 08 9921 1338
geralton@ashdown-ingram.com.au
Kalgoorlie
200 Boulder Road
Kalgoorlie 6430
P: 08 9021 5211
kalgoorlie@ashdown-ingram.com.au
Karratha
Unit 1, Lot 991
Croydon Road
Karratha 6714
P: 08 9183 8117
karratha@ashdown-ingram.com.au
Kewdale
499 Abernethy Road
Kewdale 6105
P: 08 9376 2544
kewdale@ashdown-ingram.com.au
Osborne Park
Unit 2, 3 McDonald Street
Osborne Park 6017
P: 08 9444 8644
osbornepark@ashdown-ingram.com.au
SOUTH AUSTRALIA
Regency Park
1 Pambula Street
Regency Park 5010
P: 08 8347 1637
regencypark@ashdown-ingram.com.au
Thebarton
36-38 Cawthorne Street
Thebarton 5031
P: 08 8257 2345
thebarton@ashdown-ingram.com.au
Unit 10, Winnellie Central
Hickman Street
Winnellie 0820
P: 08 8984 4222
darwin@ashdown-ingram.com.au
NEW SOUTH WALES
Albury
130 North Street
Albury 2640
P: 02 6041 4443
albury@ashdown-ingram.com.au
Alexandria
Unit E8
46 Maddox Street
Alexandria 2015
P: 02 9516 3022
alexandria@ashdown-ingram.com.au
Canberra
Unit 1,
168 Gladstone Street
Fyshwick 2609
P: 02 6280 6154
canberra@ashdown-ingram.com.au
Coffs Harbour
Unit 1, 201 Breen Street
Golden Square 3555
P: 03 5443 1900
bendigo@ashdown-ingram.com.au
North Geelong
470 Melbourne Road
North Geelong 3215
P: 03 5224 2266
geelong@ashdown-ingram.com.au
Sandown
13-15 Brough Street
Sandown 3171
P: 03 9548 2266
sandown@ashdown-ingram.com.au
Sunshine West
Unit 6, 42-48 Vella Drive
Sunshine 3020
P: 03 9364 7466
sunshinewest@ashdown-ingram.com.au
Traralgon
5 Rocla Road
Traralgon East 3844
P: 03 5174 9492
traralgon@ashdown-ingram.com.au
Unit 1, 19 Forge Drive
North Boambee Valley
Coffs Harbour 2450
P: 02 6652 2932
coffsharbour@ashdown-ingram.com.au
Tullamarine
Dubbo
NEW ZEALAND
2 McKenzie Street
Dubbo 2830
P: 02 6885 2766
dubbo@ashdown-ingram.com.au
Lidcombe
Unit 2, 9 Parramatta Road
Lidcombe 2141
P: 02 9648 1900
lidcombe@ashdown-ingram.com.au
Newcastle
14 Broadmeadow Road
Broadmeadow 2292
P: 02 4961 3988
newcastle@ashdown-ingram.com.au
Tamworth
67 Gunnedah Road
Tamworth 2340
P: 02 6765 3199
tamworth@ashdown-ingram.com.au
Wagga Wagga
TASMANIA
Unit 1, 12 Mortimer Place
Wagga Wagga 2650
P: 02 6925 5266
waggawagga@ashdown-ingram.com.au
Hobart
Wetherill Park
2A Pierce Street
Moonah 7009
P: 03 6228 0200
hobart@ashdown-ingram.com.au
30B Industrial Road
Unanderra 2526
P: 02 4271 2611
wollongong@ashdown-ingram.com.au
Unit 1, 42 Newton Road
Wetherill Park 2164
P: 02 9616 0100
wetherillpark@ashdown-ingram.com.au
Copyright © 2013 Ashdown-Ingram ABN 97 097 993 283
9 Tullamarine Park Road
Tullamarine 3043
P: 03 8336 6444
tullamarine@ashdown-ingram.com.au
Auckland
22 Sylvia Park Road
Mt. Wellington 1060
P: +64 9 5730 680
auckland@ashdown-ingram.co.nz
Hamilton
126 Ellis Street
Frankton 3204
P: +64 7 8471 400
hamilton@ashdown-ingram.co.nz
Christchurch
48 Wordsworth Street
Sydenham 8023
P: +64 3 3712 770
christchurch@ashdown-ingram.co.nz
Download