SIDACtor Device SIDACtor Device The modified TO-220 Type 61 SIDACtor solid state protection device can be used in telecommunication protection applications that do not reference earth ground. SIDACtor devices are used to enable equipment to meet various regulatory requirements including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A (formerly known as FCC Part 68). Electrical Parameters Part Number * VDRM Volts VS Volts VT Volts IDRM µAmps IS mAmps IT Amps IH mAmps CO pF P2000AA61 180 220 4 5 800 2.2 150 30 P2200AA61 200 240 4 5 800 2.2 150 30 P2400AA61 220 260 4 5 800 2.2 150 30 P2500AA61 240 290 4 5 800 2.2 150 30 P3000AA61 270 330 4 5 800 2.2 150 30 P3300AA61 300 360 4 5 800 2.2 150 30 * For surge ratings, see table below. General Notes: • All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range. • IPP is a repetitive surge rating and is guaranteed for the life of the product. • Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities. • VDRM is measured at IDRM. • VS is measured at 100 V/µs. • Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request. • Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value. Surge Ratings Series IPP 0.2x310 µs Amps IPP 2x10 µs Amps IPP 8x20 µs Amps IPP 10x160 µs Amps IPP 10x560 µs Amps IPP 5x320 µs Amps IPP 10x1000 µs Amps ITSM 60 Hz Amps di/dt Amps/µs A 20 150 150 90 50 75 45 20 500 http://www.littelfuse.com +1 972-580-7777 2 - 28 © 2004 Littelfuse, Inc. SIDACtor® Data Book and Design Guide SIDACtor Device Thermal Considerations Package Symbol Modified TO-220 Type 61 Parameter Value Unit TJ Operating Junction Temperature Range -40 to +150 °C TS Storage Temperature Range -65 to +150 °C 50 °C/W Thermal Resistance: Junction to Ambient Data Sheets RθJA IPP – Peak Pulse Current – %IPP +I +I IITT ISS IH I DRM -V -V +V +V V VTT V VDRM DRM V VS S Peak Value 100 tr = rise time to peak value td = decay time to half value Waveform = tr x td 50 Half Value 0 0 tr td t – Time (µs) -I -I V-I Characteristics tr x td Pulse Wave-form IH 8 6 25 ˚C 4 2 IH (TC = 25 ˚C) 10 Ratio of Percent of VS Change – % 14 12 0 -4 2.0 1.8 1.6 1.4 25 ˚C 1.2 1.0 0.8 0.6 0.4 -40 -20 0 -6 -8 -40 -20 0 20 40 60 80 100 120 140 160 Case Temperature (TC) – ˚C 20 40 60 80 100 120 140 160 Junction Temperature (TJ) – ˚C Normalized VS Change versus Junction Temperature © 2004 Littelfuse, Inc. SIDACtor® Data Book and Design Guide Normalized DC Holding Current versus Case Temperature 2 - 29 http://www.littelfuse.com +1 972-580-7777 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Littelfuse: P3300AA61RP P2000AA61RP