Product Code Index C P 4 0 4 D E F 1 / F F 1 0 F 1 2 F 2 3 F R T 1 G 1 0 G A M 3 H 1 0 H 1 E L A 5 L P 1 L P 2 L P 3 L V 1 L V C 1 M 1 S P S R 1 P S U R 1 E R 2 U R R P 1 S F 1 S S F 2 T 1 0 T 1 I T 1 I / P T 1 P T 1 R T 2 D T 2 M T 3 M T H C 1 T N E T P 2 T P 4 0 4 T P R 1 V 1 C V 1 E V 3 E V 3 E / N W A 5 6 1 3 3 3 7 3 3 4 4 5 5 5 6 1 2 2 7 6 7 1 2 3 6 7 7 7 1 2 7 1 6 2 4 3 4 4 5 4 7 1 1 1 1 3 5 7 9 1 5 8 1 9 1 3 2 8 5 1 5 7 9 3 4 6 3 7 7 3 5 0 9 5 6 9 5 9 1 3 3 1 Product Description Index 3 P H A S E + N E U T R A L O V E R / U N D E R V O L T A 3 P H A S E O V E R / U N D E R V O L T A G E M O N I T O A L A R M M O D U L E C A P A C I T I V E L E V E L C O N T R O L L E R C U R R E N T M O N I T O R C U R R E N T W I N D O W C O M P A R A T O R D E F R O S T T I M E R D E L A Y O N R E L E A S E D I G I T A L T I M E R ( M U L T I - F U N C T I O N ) E Q U A L R E P E A T I N G F L I P - F L O P R E L A Y S F O R W A R D / R E V E R S E T I M E R F R E Q U E N C Y M O N I T O R F R E Q U E N C Y W I N D O W C O M P A R A T O R I N T E R V A L T I M E R L I Q U I D L E V E L C O N T R O L L E R M U L T I - S T A R T A T T E M P T M U L T I - F U N C T I O N M U L T I - R A N G E T I M E R M U L T I - R A N G E I N S T A N T A N E O U S N A M U R S E N S O R R E L A Y O N - D E L A Y T I M E R O N E - S H O T T I M E R P H A S E - F A I L U R E / P H A S E S E Q U E N C E M O N I P O W E R S U P P L Y U N I T P R E - S E L E C T C O U N T E R P U L S E C O N T R O L L E D I N T E R V A L T I M E R P U M P P R O T E C T I O N R E L A Y ( S I N G L E P H A S E P U M P P R O T E C T I O N R E L A Y ( S I N G L E P H A S E P U M P P R O T E C T I O N R E L A Y ( T H R E E P H A S E ) P U M P S E Q U E N C E R E L A Y S I N G L E P H A S E O V E R / U N D E R V O L T A G E M S O L I D S T A T E F L A S H E R S T A R D E L T A T A C H O M E T E R R E L A Y T E M P E R A T U R E C O N T R O L L E R T H E R M I S T O R M O T O R P R O T E C T I O N R E L A Y T W O - S H O T T I M E R T W O H A N D C O N T R O L M O D U L E U N E Q U A L R E P E A T I N G V O L T A G E M O N I T O R G E M O N I T O R R T O R ) ) O N I T O R 43 41 35 21 51 53 17 7 66 75 31 71 47 49 74 19 33 3 5 23 73 13 37 68 64 76 55 58 61 72 39 69 9 25 27 29 15 70 11 45 2 T2M Multi-Function Multi-Range Timer Description Microprocessor based Multi-function timer with four select able modes of operation and time range from 0.3sec - 60hrs. Extens ive applications due to combinati on of functions and time ranges. Due to the advanced design of the unit a high accuracy can be achieved. Al l commonly used functions are incorporated in the unit. Any adjustment on the front potentiometer after the supply is applied is not acknowledged. This prevents unwanted changes of the time range. For a unit with a instantaneous contact the T3M can be used. FEATURES Microprocessor based design Time range 0.3sec - 60hrs Rear DIP switch selection of 4 function Rear DIP switch selection of 8 timer ranges Potentiometer adjustable time setting Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Pulse Duration Output Specifications A Pins 5 & 6 open 0.3 - 6sec 3 - 60 sec 0.3 - 6min 3 - 6 min B Pins 5 & 6 closed 0.3 - 6min 3 - 60 min 0.3 - 6 hrs 3 - 6 hrs (Galvanic) Isolation Consumption Rated Isolation Voltage DPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.5% 5% Nominal Rate in AC1 1500 VA ( Ag-Ni ) 0.2% 0.05% / V 0.2% / oC Rated Current 5A Rated Voltage 250V Mechanical Life 500 ms 500 ms (pins 6 & 7) Supply Specifications Power Supply AC Type Output Specifications Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 3 T2M Multi-Function Multi-Range Timer Mode of Operations Function 1: Delay On Operate Function 2: Interval When applying supply the relay is de-energized and timing starts. The relay only energizes after the set time is elapsed and will remain so until the supply is removed. Example Delaying energization of a load on applying power. Function 3: Pulse Controlled Interval When applying the supply the relay is energized and remains so until the set time is elapsed. The relay will then de-energize until the supply is removed and reapplied. Example Function 4: Equal Repeating Permanent supply is applied to the unit. When closing contacts 6 & 7 the relay energises for the set time period. The relay then de-energizes until contacts 6 & 7 are closed again. Example Delaying release after limit switch operation. Energization of a load for a set time period. When applying supply the set OF time period is activated where after an equal ON time begins. This cycle is repeated until the supply is removed. Example Switching a load on and off repetitively in equal intervals. Wiring Diagram Operations Diagram 4 T3M Multi-Range Instantaneous Description Microprocessor based Multi -function timer with four s electable modes of operati on and time range from 0.3sec - 60hrs. Extensive appli cations due to combinations of functions and time ranges. Due to the advanced design of the unit a high accuracy can be achieved. All commonly used functions are incorporated in the unit. Any adjustment on the front potentiometer after the supply is applied is not acknowledged. This prevents unwanted changes of the time range. The instantaneous contact in the unit can be used in a hold-in circuit or where an output is needed immediately when the supply is applied. For a unit without an instantaneous con tact the T2M can be used. FEATURES Microprocessor based design Time range 0.3sec - 60hrs Rear DIP switch selection of 4 function Rear DIP switch selection of 8 timer ranges Potentiometer adjustable time setting Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Delay output 10A SPDT Instantaneous output 10A SPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Pulse Duration Output Specifications A Pins 5 & 6 open 0.3 - 6sec 3 - 60 sec 0.3 - 6min 3 - 6 min B Pins 5 & 6 closed 0.3 - 6min 3 - 60 min 0.3 - 6 hrs 3 - 6 hrs (Galvanic) Isolation Consumption Rated Isolation Voltage SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.5% Nominal Rate in AC1 5% 1500 VA ( Ag-Ni ) 0.2% 0.05% / V o 0.2% / C Rated Current 10A Rated Voltage 250V Mechanical Life 500 ms 500 ms (pins 6 & 7) Supply Specifications Power Supply AC Type Output Specifications Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 5 T3M Multi-Range Instantaneous Mode of Operations Function 1: Delay On Operate Function 2: Interval When applying supply the relay is de-energized and timing starts. The relay only energizes after the set time is elapsed and will remain so until the supply is removed. Example Delaying energization of a load on applying power. Function 3: Pulse Controlled Interval When applying the supply the relay is energized and remains so until the set time is elapsed. The relay will then de-energize until the supply is removed and reapplied. Example Function 4: Equal Repeating Permanent supply is applied to the unit. When closing contacts 6 & 7 the relay energises for the set time period. The relay then de-energizes until contacts 6 & 7 are closed again. Example Delaying release after limit switch operation. Energization of a load for a set time period. When applying supply the set OF time period is activated where after an equal ON time begins. This cycle is repeated until the supply is removed. Example Switching a load on and off repetitively in equal intervals. WIRING DIAGRAM Operations Diagram 6 T2D Delay On Release Description The unit provides delayed release of relay after the supply has been removed. Time ranges from 10 - 180min are supplied with internal battery which has to be charg ed for 24 hours before it is first used. Power must be supplied for ± 30% of time range before removed to charge internal retaining circuit. In applications where supply voltage is present the pulse controlled interval timer (T2M or T1I/P) should be used. FEATURES Time range 3 - 360sec without battery Time range 10 - 180min with battery Potentiometer adjustable time setting Oscillator control time circuit Repeatable deviation: < 1% LED indication for power supply ON Output 5A DPDT Time Specifications Time Ranges Range Accuracy Output Specifications Without battery 3 sec 10 sec 30 sec 60 sec 180 sec 360 sec With battery 10 min 30 min 60 min 180 min 0.5% Scale Accuracy 5% Repeat Accuracy 1% Time Variation within rated power supply and ambient temperature Reset Time (Galvanic) Isolation Consumption Rated Isolation Voltage Nominal Rate in AC1 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA Rated Current 5A Rated Voltage 250V Mechanical Life 0.2% / oC Electrical Life 500 ms DPDT ( Ag-Ni ) 0.05% / V Supply Specifications Power Supply AC Type Output Specifications Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 7 T2D Delay On Release Mode of Operations Function: Delay on Release Applying supply energizes relay. When removing the supply, the relay remains energized for the set time period and then de-energizes. Example - Prevention of unnecessary generator set initiation due to brief supply failure. - Prevention of unnecessary equipment shut-down due to brief supply failure. - Power supply failure alarm timing. Wiring Diagram Operations Diagram 8 TNE Star Delta Description The unit is designed to enable star-delta starters to switch between star and delta safely. The star-make period can be adjusted with the front potentiometer. A set pause time of ± 80ms prev ent contractors operating simultaneously. FEATURES Oscillator control time circuit Potentiometer adjustable time setting Failsafe operation Repeatable deviation: < 1% LED indication for STAR and DELTA outputs Output 10A SPDT Time Specifications Time Ranges Delay between Star & Delta Output Specifications 1 - 30 sec 3 - 60 sc 10 - 180 secs Output Specifications Rated Isolation Voltage ± 80ms SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) Outputs Range Accuracy 5% Scale Accuracy 5% Repeat Accuracy 1% within rated power supply and ambient temperature Mechanical Life 0.2% / oC Electrical Life Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption Rated Current 0.05% / V 500 ms 1500 VA ( Ag-Ni ) Rated Voltage Time Variation Reset Time Nominal Rate in AC1 Operation Frequency 10A 250V 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Star ON Delta ON LED green LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 9 TNE Star Delta Mode of Operations Function: Star Delta On applying supply, contact 1 & 4 is made and the set STAR time period begins. On expiry of time period contacts 1 & 4 opens and remains in a neutral position for ± 80ms, after which DELTA connection is made between contacts 1 &3. The relay remains in this position until supply is removed at which time it will de-energize to a center-off position. Example Timed switching on a Star/Delta starter to prevent simultaneous operating of the contactors. Wiring Diagram Operations Diagram 10 R2U Unequal Repeating Description Microprocessor based unequal repeating timer with two selectable modes of operation and eight separately selectable ON and OFF time ranges from 0.3sec - 60hrs. The ON and OFF times can only be selected from the A or B range and not both. Extensive applications due to combination of functions and time ranges. Due to the advance design of the unit a high accuracy can be achieved. Any adjustable on the front potentiometer after the supply is applied is not acknowledged. This prevents unwanted changes of the time range. The ON and OFF times can be adjusted independently. FEATURES Microprocessor based design Time range 0.3sec - 60hrs Rear DIP switch selection of 8 separate ON and OFF timer ranges Separate potentiometer adjustable time settings for ON and OFF period Selectable ON or OFF time first Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Output Specifications A Pins 5 & 6 open 0.3 - 6sec 3 - 60 sec 0.3 - 6min 3 - 6 min B Pins 5 & 6 closed 0.3 - 6min 3 - 60 min 0.3 - 6 hrs 3 - 6 hrs 0.5% 5% 0.2% 0.05% / V 0.2% / oC Output Specifications Rated Isolation Voltage Nominal Rate in AC1 500 ms Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Rated Current 5A Rated Voltage 250V Mechanical Life Electrical Life Reset Time DPDT Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption None ± 100 mA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 11 R2U Unequal Repeating Mode of Operations Function ON First Applying the supply activates the set ON period, where after the separately selectable OFF time is activated. This cycle continues until the supply is removed. Example Function OFF First Applying the supply activates the set OFF period, where after the separately selectable ON time is activated. This cycle continues until the supply is removed. - Chemical dosing and mixing. - Periodic lubrication control for equipment. Wiring Diagram Operations Diagram 12 T1P One Shot Timer Description Single function non-adjustable timer to initiate a 0.5sec pulse on energization and/or de-energization. By bridging contracts 5 & 6 the relay will only pulse on application of the supply and by bridging out contract 6 & 7 the relay will only pulse when the supply is removed. The supply has to remain on for at least 3 seconds for the pulse on removing of power to function correctly. A 1 second pulse can be supplied on demand. FEATURES Selectable pulse on energization and/or de-energization Non-adjustable pulse length of 0.5 seconds (1s on demand) LED indication for power supply ON Output 10A SPDT Time Specifications Time Ranges Output Specifications 0.5 sec pulse Range Accuracy 0.5% Repeat Accuracy 0.2% Time Variation within rated power supply and ambient temperature Reset Time Output Specifications Rated Isolation Voltage 0.05% / V 0.2% / oC Nominal Rate in AC1 1s Rated Current 10A 250V 6 10x10 cycles 3 110x10 cycles (at max load) Electrical Life Supply Specifications 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms Consumption ± 3VA 12,24,48 V ± 10% (Non-galvanic) Consumption General Specifications Power ON Delay None Isolation 1800 cycles/h 110, 230, 400V, 525V ± 10% Isolation Power Supply DC Types 1500 VA Rated Voltage Operation Frequency (Non-galvanic) 6000 VAC (contact / electric) 1000 VAC (contact / contact) ( Ag-Ni ) Mechanical Life Power Supply AC Type DPDT None ± 100 mA Indication for Power Supply ON LED red Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 13 T1P One Shot Timer Mode of Operations One-shot Provides a 0.5sec pulse when relay is energized and/or de-energized. Bridging pins 5 & 6 the relay will pulse on application of supply only. Bridging pins 6 & 7 the relay will pulse on disconnection of supply only. Example - Change of state at power up or down - Power up or down indication Wiring Diagram Operations Diagram 14 TP2 Two-Shot Timer Description Microprocessor based two-shot timer with two selectable modes of operation and eight separately selectable ON and OFF time ranges from 0.3sec - 60hrs. The ON and OFF ti mes can only be selected from the A or B range and not both. Extensive applications due to combination of functions and time ranges. Due to the advanced design of the unit a high accuracy can be achieved. Any adjustment on the front potentiometers after the supply is applied is not acknowledged. This prevents unwanted changes of the time range. The ON and OFF times can be adjusted independently. FEATURES Microprocessor based design Time range 0.3sec - 60hrs Rear DIP switch selection of 8 separate ON and OFF timer ranges Separate potentiometer adjustable time settings for ON and OFF period Selectable ON or OFF time first Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Pulse Duration Output Specifications A Pins 5 & 6 open 0.3 - 6sec 3 - 60 sec 0.3 - 6min 3 - 6 min B Pins 5 & 6 closed 0.3 - 6min 3 - 60 min 0.3 - 6 hrs 3 - 6 hrs (Galvanic) Isolation Consumption Rated Isolation Voltage DPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.5% 5% Nominal Rate in AC1 1500 VA ( Ag-Ni ) 0.2% 0.05% / V 0.2% / oC Rated Current 5A Rated Voltage 250V Mechanical Life 500 ms 500 ms (pins 6 & 7) Supply Specifications Power Supply AC Type Output Specifications Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption None ± 100 mA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 15 Tp2 Two-Shot Timer Mode of Operations Function OFF First Applying supply activates the set OFF period, where after the separately set ON time is activated. On expiry of the ON period the relay energizes until the supply is removed. Example Function ON First Applying supply activates the set ON period, where after the separately set OFF time is activated. On expiry of the OFF period the relay energizes until the supply is removed. - Activating a siren after a specific time period. - Chemical dosing. Wiring Diagram Operations Diagram 16 DEF1/F Defrost Timer Description Microprocessor based defrost timer with four selectable cycle times and separately adjustable fan delay of 3 - 60 seconds and defrost time range from 0.3 - 60 minutes. The defrost time can be overridden, starting the cooling time first when contact 5 & 6 are bridged permanently. Contact 5 & 6 can also be used as a temperature override. Closing contact 5 & 6 during the defrost cycle will start the cooling cycle. Any adjustment on the front potentiometers after the supply is applied is not acknowledged. This prevents unwanted changes of the time range. FEATURES Microprocessor based design Cycle time ranges 4, 6, 8, 12 hours via rear DIP switch Separate potentiometer adjustable time settings for DEFROST and FAN DELAY period Selectable defrost time ON or OFF first Temperature override input Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Time Specifications Cycle Time Ranges Output Specifications 4, 6, 8, 12 hours Output Specifications Defrost Time Ranges 3 - 60 minutes Rated Isolation Fan Delay Time Range 0.3 - 6 minutes Voltage Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time 0.5% 0.2% Nominal Rate in AC1 Consumption 500 ms Rated Current 5A Rated Voltage 250V Mechanical Life Consumption 1800 cycles/h General Specifications Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA 12,24,48 V ± 10% (Non-galvanic) Isolation 6 10x10 cycles 3 110x10 cycles (at max load) 110, 230, 400V, 525V ± 10% ± 6VA 525 V Power Supply DC Types 1500 VA 0.05% / V 0.2% / oC Supply Specifications Isolation (contact / electric) 1000 VAC (contact / contact) ( Ag-Ni ) Electrical Life (Galvanic) 6000 VAC 5% Operation Frequency Power Supply AC Type SPDT Indication for Power Supply ON Defrost ON Cooling Fan Delay LED red Defrost LED green (flashing) Defrost LED green Fan LED green (flashing) Environment None ± 100 mA Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 17 DEF1/F Defrost Timer Mode of Operations Defrost Timer Applying supply activates the set defrost time, where after the cooling time continues. At the beginning of the cooling time the set fan delay time starts to prevent hot air from blowing into the cool room, after which the fan starts. The cycle time consists of both the cooling and the defrost time. Bridging pins 5 & 6 permanently activates the cooling time when the supply is applied. If pins 5 & 6 are only pulsed in the defrost time the cooling time starts. This function can be used to cut short the defrost time if a thermostat is connected to pins 5 & 6 and closes at the set temperature. Wiring Diagram Operations Diagram 18 LV1 Liquid Level Controller Description Level control unit of conductive liquids which can be configured for FILLING or EMPTYING. The unit can be used as a two probe system for alarm purposes or a three probe system to control HIGH and LOW levels of a reservoir. Up to four LV1 can be utilized in the same reservoir by connecting all commons (pin 7). The sensitivity of the unit can also be adjusted. FEATURES Fail-safe control feature Rear DIP switch selectable FILLING / EMPTYING Adjustable sensitivity Modulated AC probe signal to prevent electrolytic corrosion Low voltage probe signal Power supply ON and Relay ON LEDs Output 10A SPDT Level Sensing Input Specifications Output Specifications Probe Voltage 4 VAC Output Specifications Probe Current 2.5mA Rated Isolation Voltage Probe Frequency 100Hz Sensitivity 4 - 50k Response Time Max. Probe Cable Length 400 m Nominal Rate in AC1 Rated Current 10A Rated Voltage 250V Electrical Life Operation Frequency Supply Specifications Isolation Consumption 1500 VA ( Ag-Ni ) Mechanical Life (Galvanic) 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1 sec 2.5 twin and earth screened Power Supply AC Type SPDT 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 19 LV1 Liquid Level Controller Mode of Operations Filling Emptying When the level of the reservoir drops below the low level probe the relay will energize. The relay remain energized until the level of the reservoir rises to the high level probe. The relay de-energizes when the high level probe is submerged and will remain off until the level drops below the low level probe. Example Level control for conductive liquids Filling a reservoir. When the level of the reservoir rises to the high level probe the relay energizes. The relay remains energized until the low level probe is no longer submerged. When the level passes below the low level probe the relay de-energizes and remains of until the level reaches the high level probe again. Example Emptying a reservoir 2 wire control over long distance. Wiring Diagram Operations Diagram 20 LVC1 Capacitive Level Controller Description Level control unit for any liquids or granules which can be configured for FILLING or EMPTYING. The unit can be used as a one probe system for alarm purposes or a two probe system to control HIGH and LOW levels or a reservoir. A power supply for the two NPN capacitive proximity sensors is built in to the unit. FEATURES Fail-safe control feature Rear DIP switch selectable FILLING / EMPTYING Power supply for two 3 wire NPN proximity switch Power supply ON and Relay ON LEDs Output 10A SPDT Sensor Specifications Probe Type NPN 3 wire proximity switch Pin 7 - supply Pin 9 + supply Pin 6 Low level probe input Pin 5 High level probe input Probe Voltage Short Circuit Current Response Time 24 VDC Output Specifications Output Specifications Rated Isolation Voltage Nominal Rate in AC1 Rated Current 10A Rated Voltage 250V Operation Frequency Supply Specifications Isolation Consumption 1500 VA 25mA max 1 sec Electrical Life (Galvanic) 6000 VAC (contact / electric) 1000 VAC (contact / contact) ( Ag-Ni ) Mechanical Life Power Supply AC Type SPDT 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED green LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption None ± 100 mA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 21 LVC1 Capacitive Level Controller Mode of Operations Filling Emptying When the liquid is not in contact with the HIGH and LOW probe the relay is energized. If the level reaches the HIGH probe the relay will deenergize and will remain OFF until the level falls below the LOW level probe. Example Controlling a pump to fill a reservoir. When the liquid is not in contact with the HIGH and LOW probe the relay is de-energized. If the level reaches the HIGH probe the relay will energize and will remain ON until the level falls below the LOW level probe. Example Controlling the draining of a reservoir. Wiring Diagram Operations Diagram 22 M1S Namur Sensor Relay Description Control unit for two wire Namur sensors. The unit monitors current flow through the Namur sensor and can be configured for target response and space response by connecting the sensor to either 5 & 6 or 6 & 7 respectively. FEATURES Fail-safe control feature Direct connection for Namur two wire proximity sensor Selectable to energize or de-energize when sensor is activated Low power sensor signal LED indication for relay ON Output 10A SPDT Sensor Specifications Probe Type 2 wire Namur Pin 6 Common Pin 5 Target sensing input Pin 7 Probe Voltage Short Circuit Current Maximum Sensing Speed Output Specifications Output Specifications Rated Isolation Voltage Space sensing input 10mA max Nominal Rate in AC1 25 Hz Rated Current 10A Rated Voltage 250V Operation Frequency Supply Specifications Isolation Consumption 1500 VA ( Ag-Ni ) Electrical Life (Galvanic) 6000 VAC (contact / electric) 1000 VAC (contact / contact) 8.2 VDC Mechanical Life Power Supply AC Type SPDT 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% Environment Degree Of Protection IP 20 (Non-galvanic) Operating Temperature -10 to + 50oC Isolation Storage Temperature -50 to + 85oC Consumption None ± 100 mA Weight 200g 23 M1S Namur Sensor Relay Mode of Operations Target Sensing The relay will energize when the Namur Sensor is activated. When the Namur sensor is not activated, the relay is de-energized Example Space Sensing The relay will de-energize when the Namur sensor is active. When the Namur sensor is not activated, the relay is energized. Sensing in hostile environment Long distance sensing (between sensor and amplifier). Wiring Diagram Operations Diagram 24 RRP1 Tachometer Relay Description Microprocess or based Multi-function tachometer relay with four selectable speeds. The unit can be selected for OVER and UNDER speeds and interfaces directly with a Namur two wire proximity sensor or limit switch. FEATURES Microprocessor based design Programmable speed ranges: 1-10000 RPM Rear DIP switch selection of UNDER / OVER speed Rear DIP switch selection for 10sec start-up delay Potentiometer adjustable speed setting Oscillator controlled measurement circuit Power supply ON and Relay ON LEDs Output 5A DPDT Speed Specifications Speed Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Speed RPM 1 - 10 10 - 100 100 - 1000 1000 - 10000 Output Specifications Response Time 60 sec 10 sec 6 sec 1 sec Output Specifications Rated Isolation Voltage 5% Nominal Rate in AC1 0.05% / V 0.2% / oC Rated Current 5A Rated Voltage 250V Mechanical Life 500 ms Electrical Life Consumption General Specifications Power ON Delay 300 ms Power OFF Delay 200 ms 4kV Indication for Power Supply ON Output ON 12,24,48 V ± 10% (Non-galvanic) Consumption LED red LED green ± 3VA Environment Degree Of Protection Isolation 1800 cycles/h 110, 230, 400V ± 6VA 525 V Power Supply DC Types 6 10x10 cycles 3 110x10 cycles (at max load) 525V ± 10% 50 / 60 Hz ± 5Hz Isolation 1500 VA ( Ag-Ni ) 0.2% Supply Specifications (Galvanic) 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.5% Operation Frequency Power Supply AC Type SPDT None IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g ± 100 mA 25 RRP1 Tachometer Relay Mode of Operations Over Speed Under Speed The relay will de-energize if the speed exceeds the set limit. If the speed reduces by 5% of the set value the relay will energize. Example Starter motor disabling on generator. The relay will de-energize if the speed drops below the set limit. If the speed increases by 5% of the set value the relay will energize. Example Example Detection of conveyor belt break. Wiring Diagram Operations Diagram 26 T1R Temperature Controller Description Temperature control unit for a standard three wire PT100 resistive temperature sensor with two selectable temperature ranges. The unit can be configured for OVER or UNDER temperature and has an adjustment for temperature and hysteresis. FEATURES Fail-safe control feature Direct connection to PT100 temperature sensor Rear DIP switch selection of 2 temperature ranges Potentiometer adjustable temperature setting Potentiometer adjustable hysteresis setting Power supply ON and Relay ON LEDs Output 10A SPDT Sensor Specifications Probe Type Pt100 3 wire (bridge 6 & 7 for 2 wire) Probe Voltage Output Specifications Output Specifications Rated Isolation Voltage 200mV Short Circuit Current 1mA max Standard Temperature -20 - 80ºC Ranges 80 - 180ºC Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V 6 10x10 cycles 3 110x10 cycles (at max load) Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 27 T1R Temperature Controller Mode of Operations Over Temperature Under Speed The relay will de-energize if the temperature exceeds the set limit If the temperature reduces by the percentage hysteresis of the set value the relay will energize. Example - Protection for over heating of equipment The relay will de-energize if the temperature drops below the set limit. If the temperature increases by the percentage hysteresis of the set value the relay will energize. Example - Cooling plant installation Wiring Diagram Operations Diagram 28 TPR1 Thermistor Motor Protection Relay Description Thermistor motor protection unit which interfaces directly to a PTC sensor to provide protection of motors, alternators, transformers, etc. The unit will trip if the nominal trip temperature fo the sensor is exceeded. The fault latching facility is incorporated which can be reset via the front panel membrane switch or opening contacts 7 & 8. A test facility to simulate fault conditions is also incorporated on the front panel membrane switch. FEATURES Fail-safe control feature Direct connection to PTC sensor Connect up to six thermistors Latching facility Test / reset button to simulate fault condition and reset latch Cable or sensor fault detection Power supply ON and Relay ON LEDs Output 10A SPDT Sensor Specifications Sensor Type PTC Input Impedance 2200 Short-Circuit Current 1 mA Open Circuit Voltage Response Time Output Specifications Output Specifications Rated Isolation Voltage > 2.5mV SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) .05 sec 1500 Nominal Rate in AC1 Trip Threshold 3100 Rated Current 10A Recovery Threshold 1600 Rated Voltage 250V Short-Circuit Detection < 20 Repetitive Accuracy 0.5% Max Cold Resistance of 1500 VA ( Ag-Ni ) PTC Sensor Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption Consumption General Specifications Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON Cable fault LED red LED green Power LED (flashing) 12,24,48 V ± 10% Environment (Non-galvanic) Isolation 1800 cycles/h 110, 230, 400V, 525V ± 10% ± 6VA 525 V Power Supply DC Types 6 10x10 cycles 3 110x10 cycles (at max load) Degree Of Protection None ± 100 mA IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 29 TPR1 Thermistor Motor Protection Relay Mode of Operations Thermistor Motor Protection Under normal conditions the relay is energized. If one of the thermistors reaches nominal trip temperature the relay will de-energize. If the latch is connected between 8 & 9 the relay will only re-energize if the latch is opened or the front panel membrane switch is pressed and the temperature falls at least 5% below trip value. Under normal running conditions the front panel membrane switch can be pressed to imitate a trip condition. The relay will de-energize and re-energize after a set time period. Example A thermistor imbedded in the windings of a motor will reach the trip temperature to protect the motor from overheating. Wiring Diagram Operations Diagram 30 F10 / F12 / F23 Flip-Flop Relays Description Flip-flop relays to control many applications such as spreading workload and controlling conveyor direction. Main controlled flip-flop with memory has to be energized for at least 30 seconds before the supply is removed. A delay of at least 10 seconds has to be complied to ensure proper functioning. FEATURES F10: Pulse controlled flip-flop with memory F12: Pulse controlled flip-flop without memory F23: Mains controlled flip-flop with memory Power supply ON LED Output 10A SPDT Time Specifications Output Specifications 500 ms Output Specifications Minimum ON Time 30 sec Rated Isolation Voltage Pulse Duration 0.5 sec Delay Between Pulses 10 sec Reset Time Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% Environment (Non-galvanic) Isolation Consumption Degree Of Protection None ± 100 mA IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 31 F10 / F12 / F23 Flip-Flop Relays Mode of Operations Function F10 Function F12 Pulse-controlled flip-flop with memory. With supply connected closure of contacts 5 & 7 will change the state of the relay and will remain in that state even if power supply os removed. Example Changing direction on a conveyor line. Pulse-controlled flip-flop without memory. With supply connected closure of contacts 5 & 7 will change the relay state. If supply is removed the relay will de-energize. Example Emptying a reservoir 2 wire control over long distance. Function F23 Mains controlled flip-flop with memory. Applying power 30 sec and removing it changes the relay state. Example Change over control for duty cycling of pumps Wiring Diagram Operations Diagram 32 G10 Multi-Start Attempt Description Multi-start attempt unit to control repetitive starting on stand-by generating sets with a separate alarm relay output. With its extended power supply range it is ideal for 12 and 24 VDC systems. The crank time, which is equal to the pause time can be adjusted via the front potentiometer. FEATURES Time range 1 - 30 sec Potentiometer adjustable cranking setting Oscillator control time circuit Extended power supply range (9 - 30VDC) Power supply ON and Alarm relay ON LEDs Output 10A SPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Output Specifications 1 - 30 sec 0.5% Output Specifications Rated Isolation Voltage 5% 0.2% SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.05% / V 0.2% / oC Nominal Rate in AC1 1500 VA ( Ag-Ni ) 500 ms Rated Current 10A Rated Voltage 250V 6 10x10 cycles 3 110x10 cycles (at max load) Mechanical Life Electrical Life Operation Frequency Supply Specifications General Specifications Power ON Delay 300 ms (Non-galvanic) Power OFF Delay 200 ms Isolation Indication for Power Supply AC Type Consumption 9 - 30 VDC 1800 cycles/h None ± 100 mA Power Supply ON Alarm ON LED red LED green Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 33 G10 Multi-Start Attempt Mode of Operations Three Start Attempt Applying supply initiates the first start attempt. If this start is successful supply should be removed. As long as the supply remains, the relay will start again after an equal dwell period. If the generator fails to start within three attempts the starting sequence will terminate and a separate alarm relay will energize. Example Repetitive starting of stand-by generator set. Wiring Diagram Operations Diagram 34 GAM3 Alarm Module Description Alarm module to control alarm signals and generate the appropriate output for simple annunciator panels. The system can be expanded by bridging all common terminals of the modules. A flasher nit (R1F) is used to initiate the flashing alarm outputs before accepting them. FEATURES Three normally open alarm inputs Three normally open alarm outputs Common lamp test facility Alarm accept facility Hooter output Flasher input Expandable Output 10A SPDT Input Specifications Alarm Inputs 3 N/O Output Specifications Alarm Outputs (Positive Common) Alarm Accept N/O (Negative Common) Hooter Outputs (Positive Common) Lamp Test 3 N/O N/O (Negative Common) N/O (Positive Common) Flasher 30 flashes per minute Supply Specifications Power Supply DC Type 12, 24 ± 10% Isolation Environment Degree Of Protection (Non-galvanic) Consumption General Specifications None ± 100 mA IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 35 GAM3 Alarm Module Mode of Operations Alarm Module Closure of any alarm contact energizes an alarm output through a common flasher unit (supplied separately) causing the lamp to flash. On acceptance of the alarm, via a common alarm accept input, the flashing lamp steadies and remains so until alarm contact is reset. The module facilities a common lamp test facility which will energize all alarm outputs. The system can be expanded by combining the modules with their only restriction being the size of the power supply. Example Example Annunciator panel control. Wiring Diagram Operations Diagram 36 SF1 Phase-Failure / Phase Sequence Monitor Description The SF1 Monitors negative phase sequence (NPS) voltage to detect phase failure, phase reversal and phase imbalance. The NPS voltage of the unit is fixed at 7%. When any of these faults occur the unit will de-energize. The relay will only re-energize if the supply voltage corrects itself. The unit will not react to a balanced voltage variation FEATURES Monitoring relay for 3 - phase voltage control Measures if all 3 phases present and in sequence Detection of phase asymmetry Insusceptible to balanced supply voltage variation Insensitive to regenerated EMF Fast response to reverse phase sequence Relay ON LED Output 10A SPDT Input Specifications Output Specifications Input Pin 5 Phase L1 Pin 6 Phase L2 Pin 7 Phase L3 Voltage Interruption Dielectric Voltage Output Specifications Rated Isolation Voltage SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) < 40ms None (supply / electronics) Nominal Rate in AC1 1500 VA ( Ag-Ni ) Rated Impulse withstand 4kV (1.2/50ms line/line) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Output ON LED green ± 6VA 525VA Environment Degree Of Protection Operating Temperature Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 37 SF1 Phase-Failure / Phase Sequence Monitor Mode of Operations Phase Failure The relay will only operate while all three phases are present, in sequence and balanced. The unit provides effective protection of phase failure / phase reversal / excessive phase imbalance and phase angle error. The units detect all the above faults by measuring the NPS voltage of the supply. The NPS voltage is fixed at 7% and can be calculated by the following formula: NPS voltage = 71 / V average (V high - ¼ V middle - ¾ V low) Example - Protects motors from single phasing and subsequently burning out - Detects phase failure and reversal on voltage transformers. - Protects forward and reverse operating machines. Wiring Diagram Operations Diagram 38 SF1/K Adjustable Phase-Failure / Phase Sequence Monitor Description The SF1 Monitors negative phase sequence (NPS) voltage to detect phase failure, phase reversal and phase imbalance. The NPS voltage of the unit can be djusted from 7-15%. When any of these faults occur the unit will de-energize. The relay will only re-energize if the supply voltage corrects itself. The unit will not react to a balanced voltage variation FEATURES Monitoring relay for 3 - phase voltage control Measures if all 3 phases present and in sequence Detection of phase asymmetry Insusceptible to balanced supply voltage variation Insensitive to regenerated EMF Fast response to reverse phase sequence Relay ON LED Output 10A SPDT Input Specifications Output Specifications Input Pin 5 Phase L1 Pin 6 Phase L2 Pin 7 Phase L3 Voltage Interruption Dielectric Voltage Output Specifications Rated Isolation Voltage SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) < 40ms None (supply / electronics) Nominal Rate in AC1 1500 VA ( Ag-Ni ) Rated Impulse withstand 4kV (1.2/50ms line/line) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Output ON LED green ± 6VA 525VA Environment Degree Of Protection Operating Temperature Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 39 V1E Single Phase Over / Under Voltage Monitor Description Single phase monitoring plug-in relay for separate upper and lower voltage control. Often used where the generated electrical power is unstable in order to secure the equipment. FEATURES Monitoring relay and measuring relay for upper / lower phase to neutral voltage control Measures if phase to neutral voltage are within set limits, present and in sequence Measures on own power supply Upper and lower limits separately adjustable LED indication for over / under volts Latch facility incorporated 10 second start-up delay 180 second response delay Output 10A SPDT Input Specifications Output Specifications Input Pin 2,10 Output Specifications L&N Rated Isolation Voltage Measuring Ranges (VAC) Range Upper Limit Lower Limit Scale Voltage Interruption Dielectric Voltage Rated Impulse Withstand 230V 241.5 - 276V ± 5 - 20% < 40ms None (supply/electronics) 4kV (1.2/50 µs line/line) Supply Specifications (Galvanic) Isolation Consumption 6000 VAC (contact / electric) 1000 VAC (contact / contact) 184 - 276V Nominal Rate in AC1 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V 6 10x10 cycles 3 110x10 cycles (at max load) Mechanical Life Electrical Life Operation Frequency Power Supply AC Type SPDT 1800 cycles/h General Specifications 1110, 230, 400V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA ± 6VA 525VA Indication for Power Supply ON Over Voltage Under Voltage LED red LED yellow LED yellow Environment Degree Of Protection Operating Temperature Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 39 V1E Single Phase Over / Under Voltage Monitor Mode of Operations Voltage Monitoring Connected to a supply, the V1E measures sinusoidal voltage. The relay operates as long as the phase - neutral voltage is within the set upper and lower limits. The two limits can be adjusted separately. If the voltage rises above the upper limit or drops below the lower limit the relay releases immediately. The relay operates again when the voltage is within set limits. Hysteresis on operate is 5% (e.g. If the unit has tripped at 260VAC it will recover at 247 VAC). Example Protecting sensitive equipment to over/under voltage fluctuations. Wiring Diagram Operations Diagram 40 V3E 3 Phase Over / Under Voltage Monitor (Incorporating Phase Reversal Detection) Description 3 - Phase monitoring plug-in relay for separate upper and lower voltage control as well as phase failure / sequence. Often used where the generated electrical power is unstable (or incorrect) in order to secure the equipment. FEATURES Monitoring relay and3 - phased measuring relay for upper / lower phase to neutral voltage control Measures if all 3 phase to phase voltages are within set limits, present and in sequence Measures on own power supply Upper and lower limits separately adjustable LED indication for over / under volts Latch facility incorporated 10 second start-up delay 180 second response delay Output 10A SPDT Input Specifications Output Specifications Pin 5 Phase L1 Output Specifications Pin 6 Phase L2 Rated Isolation Voltage Pin 7 Phase L3 Power Supply Range SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 400V 320 - 400V Nominal Rate in AC1 1500 VA ( Ag-Ni ) Upper Limit 420 - 480V Lower Limit 320 - 380V Scale Voltage Interruption Dielectric Voltage Rated Impulse Withstand ± 5 - 20% < 40ms None (supply/electronics) 4kV (1.2/50 µs line/line) Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA ± 6VA 525VA Indication for Power Supply ON Over Voltage Under Voltage LED red LED yellow LED yellow Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 41 V3E 3 Phase Over / Under Voltage Monitor (Incorporating Phase Reversal Detection) Mode of Operations Voltage Monitoring Connected to 3 phases, the V3E measures sinusoidal voltages as well as the phase failure sequence. The relay operates as long as all 3 phase to phase voltages are within the set upper and lower limits and if all phases are present and in proper sequence. The two limits can be adjusted separately. If one or more of the phase to phase voltages rises above the upper limit or drops below the lower limit, or if one phase is disconnected or out of sequence, the relay releases immediately. The relay operates again when all 3 phase to phase voltages are within set limits. Hysteresis on operate is 5% (e.g. If the unit has tripped at 440VAC it will recover at 418VAC). Example - Protects motors from single phasing and subsequently burning out. - Protects motors from reverse phase sequence on forward and reverse operating machines. Wiring Diagram Operations Diagram 42 V3E/N 3 Phase + Neutral Over / Under Voltage Monitor (Incorporating Phase Reversal Detection) Description 3 - Phase + Neutral monitoring plug-in relay for separate upper and lower voltage control as well as phase failure / sequence. Often used where the generated electrical power is unstable (or incorrect) in order to secure the equipment. FEATURES Monitoring relay and3 - phased measuring relay for upper / lower phase to neutral voltage control Measures if all 3 phase to phase voltages are within set limits, present and in sequence Measures on own power supply Upper and lower limits separately adjustable LED indication for over / under volts / phase reversal Latch facility incorporated 10 second start-up delay 180 second response delay Output 10A SPDT Input Specifications Output Specifications Pin 5 Phase L1 Output Specifications Pin 6 Phase L2 Rated Isolation Voltage Pin 7 Pin 11 Power Supply Phase L3 Neutral (phase neutral) 230V Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Range Upper Limit Lower Limit Scale Voltage Interruption Dielectric Voltage Rated Impulse Withstand 184 - 276V 241.5 - 276V Rated Current 10A 281.5 - 184V Rated Voltage 250V ± 5 - 20% < 40ms None (supply/electronics) (Galvanic) Isolation Consumption Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h 4kV (1.2/50 µs line/line) Supply Specifications Power Supply AC Type Mechanical Life General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA ± 6VA 525VA Indication for Power Supply ON Over Voltage Under Voltage LED red LED yellow LED yellow Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 43 V3E/N 3 Phase + Neutral Over / Under Voltage Monitor (Incorporating Phase Reversal Detection) Mode of Operation Voltage Monitoring Connected to 3 phases and neutral, the V3E measures sinusoidal voltages as well as the phase failure sequence. The relay operates as long as all 3 phase to neutral voltages are within the set upper and lower limits and if all phases are present and in proper sequence. The two limits can be adjusted separately. If one or more of the phase to neutral voltages rises above the upper limit or drops below the lower limit, or if one phase or neutral is disconnected or out of sequence, the relay releases immediately. The relay operates again when all 3 phase to neutral voltages are within set limits. Hysteresis on operate is 5% (e.g. If the unit has tripped at 260VAC it will recover at247VAC). Example - Protects motors from single phasing and subsequently burning out. - Protects motors from reverse phase sequence on forward and reverse operating machines. - Protects against neutral loss. Wiring Diagram Operations Diagram 44 V1C Voltage Monitor Description The V1C is a precise UNDER / OVER voltage monitoring relay. The unit can be ordered in many AC / DC voltage ranges, making it ideal for many voltage monitoring applications. The set point and hysteresis can be adjusted with separate potentiometers. The unit also incorporates a latch facility to prevent undetected failures. FEATURES Monitoring relay for voltage control Measures separate voltage input Rear DIP switch selection of UNDER / OVER voltage Rear DIP switch selection for 10 sec start-up delay Potentiometer adjustable voltage limits Potentiometer adjustable hysteresis limits Power supply ON and Relay ON LEDs Latch facility incorporated Output 10A SPDT relay Input Specifications Input Standard Measuring Ranges Internal Impedance Pin 5 & 7 4, 40, 400 VAC/DC Output Specifications Rated Isolation Voltage 500k Measurement Accuracy 1% Maximum Over Voltage + 50% Hysteresis Output Specifications 5 - 50% Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Repeat Accuracy Response Time Start-up Delay Latch Input <1% 1 sec Rated Current 10A 10 sec Rated Voltage 250V Pin 8& 9 Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption None ± 100 mA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 45 V1C Voltage Monitor Mode of Operation Over Voltage Under Voltage The relay will de-energize if the voltage drops below the set limit. IF the voltage increases by the percentage hysteresis of the set value the relay will energize. The relay will de-energize if the voltage exceeds the set limit. If the voltage reduces by the percentage hysteresis of the set value the relay will energize. Example Protection for over voltage of equipment. Example Battery charging installation. Wiring Diagram Operations Diagram 46 H10 Frequency Monitor Description The H10 is a precise UNDER/ OVER frequency monitoring relay with adjustable set point and hysteresis. The unit also incorporates a latch facility to prevent undetected failures. FEATURES Monitoring relay for upper and lower frequency control Measures if the frequency is within set limits Measures on own power supply LED indication for over / under frequency Latch facility incorporated 10 second start-up delay Output 10A SPDT Input Specifications Pin 2, 10 L&N Measuring Ranges (Hz) Output Specifications Rated Isolation Voltage Nominal Frequency 50 Hz Upper Limit 56 Hz Lower Limit 45 Hz Hysteresis Output Specifications 5% Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Repeat Accuracy < 1 sec Response Time 1 sec Start-up Delay 10 sec Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525VA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 47 H10 Frequency Monitor Mode of Operation Frequency Monitoring When a supply is applied to the unit the 10 seconds start-up delay activates energizing the relay for 10 seconds. After this time period the relay starts monitoring its own supply. If the frequency rises above 55 Hz or below 45 Hz the relay will de-energize. The relay will only re-energize if the frequency rises above 44 Hz or below 54 Hz. If the latch is activated (pin 8 & 9) the relay will not recover from a trip condition unless the latch is opened or the supply is removed. During the start-up time the latch is disabled. Example - Protection of frequency sensitive equipment - Frequency monitoring on generator sets Wiring Diagram Operations Diagram 48 H1E Frequency Window Comparator Description The H1E is a precise UNDER / OVER frequency monitoring relay. The over and under set points can be adjusted with separate potentiometers. The unit also incorporates a latch facility to prevent undetected failures. FEATURES Monitoring relay for upper and lower frequency control Measures if the frequency is within set limits Measures on own power supply Upper and lower limits separately adjustable LED indication for over / under frequency Latch facility incorporated 10 second start-up delay Output 10A SPDT Input Specifications Pin 2, 10 L&N Measuring Ranges (Hz) Output Specifications Rated Isolation Voltage Nominal Frequency 50 Hz Upper Limit 56 Hz Lower Limit 45 Hz Hysteresis Output Specifications 5% Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Repeat Accuracy Response Time Start-up Delay < 1 sec 1 sec Rated Current 10A 10 sec Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 1110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED yellow LED yellow ± 6VA 525VA Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 49 H1E Frequency Window Comparator Mode of Operation Frequency Monitoring When a supply is applied to the unit the 10 seconds start-up delay activates energizing the relay for 10 seconds. After this time period the relay starts monitoring its own supply. If the frequency rises above the set upper level or below the set lower level the relay will de-energize. The relay will only re-energize if the frequency rises 5% above the set lower level or 5% below the set upper level. If the latch is activated (pin 8 & 9) the relay will not recover from a trip condition unless the latch is opened or the supply is removed. During the start-up time the latch is disabled. Example - Protection of frequency sensitive equipment - Frequency monitoring on generator sets Wiring Diagram Operations Diagram 50 LA5 Current Monitor Description The LA5 is a precise UNDER / OVER current monitoring relay. The unit can be ordered in many AC / DC current ranges, making it ideal for many current monitoring applications. The set point and hysteresis can be adjusted with separate potentiometers. The unit also incorporates a latch facility to prevent undetected failures. For applications which necessitate a CT, all units are supplied with a terminating resistor to prevent open circuit. FEATURES Monitoring relay for current control Measures separate current input Rear DIP switch selection of UNDER / OVER current Rear DIP switch selection for 10 sec start-up delay Potentiometer adjustable current limits Potentiometer adjustable hysteresis limits Power supply ON and Relay ON LEDs Latch facility incorporated Output 10A SPDT relay Input Specifications Input Measuring Ranges (5A) Internal Resistance Maximum Overload Current Measuring Ranges (1A) Internal Resistance Pin 5 & 7 1-5A Output Specifications Output Specifications Rated Isolation Voltage 0.1 10 A (30 sec) SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.2 - 1A 5.6 Nominal Rate in AC1 1500 VA ( Ag-Ni ) Maximum Overload Current 5 A (30 sec) 5 - 50% Rated Current 10A Repeat Accuracy < 1% Rated Voltage 250V Response Time 1 sec Mechanical Life Start-up Delay 10 sec Hysteresis Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 51 LA5 Current Monitor Mode of Operation Over Current Under Current The relay will energize if the current exceeds the set limit. If the current reduces by the percentage hysteresis of the set value the relay will energize. If the latch is activated (pins 8 & 9) the relay will not recover from a trip condition unless the latch is opened or the supply is removed. During the start-up time the latch is disabled. The relay will de-energize if the current exceeds the set limit. If the current reduces by the percentage hysteresis of the set value the relay will energize. If the latch is activated (pins 8 & 9) the relay will not recover from a trip condition unless the latch is opened or the supply is removed. During the start-up time the latch is disabled. Example Protection of pumps Example Detection of conveyor belt break. Wiring Diagram Operations Diagram 52 LA5/P Pivot Monitoring Relay Description The LA5 is a precise UNDER current monitoring relay. The unit is specifically designed to monitor the motors on pivot irrigation. The trip point and response delay can be adjusted with separate potentiometers. The unit also incorporates a latch facility to prevent undetected failures and can be rest by the front mounted push button. FEATURES Monitoring relay for pivot shutdown Measures separate current input Potentiometer adjustable current limits Potentiometer adjustable response delay Power supply ON and Relay ON LEDs Latch facility incorporated with front mounted reset button Output 10A SPDT relay Input Specifications Input Measuring Ranges (5A) Internal Resistance Maximum Overload Current Pin 5 & 7 1-5A Output Specifications Output Specifications Rated Isolation Voltage 0.1 10 A (30 sec) Hysteresis 5% Repeat Accuracy 1% Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Response Time 0.5 - 10min Start-up Delay 10 sec Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED red ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 55 LA5/P Current Monitor Mode of Operation Under Current The relay will energize for the adjustable response delay. If the motor current falls below the set value and remain there for the adjustable response delay, the relay will de-energize. To restart the pump the front mounted push button has to be pressed or the unit has to be power down and up again. Example Prevention of over watering Wiring Diagram 1 3 4 2 S u p p ly 10 9 8 + M o n it o rin g Cu rre n t - 5 6 7 Operations Diagram M o n it o rin g Cu rre n t U n d e r-c u rre n t S e tp o in t Hy s t e re s is S S Re la y On 56 WA5 Current Window Comparator Description The WA5 is a precise UNDER / OVER current window monitoring relay. The unit can be ordered in many AC / DC current ranges, making it ideal for many current monitoring applications. The over and under set points can be adjusted with separate potentiometers. The unit also incorporates a latch facility to prevent undetected failures. For applications which necessitate a CT, all units are supplied with a terminating resistor to prevent open circuit. FEATURES Monitoring relay for current control Measures separate current input Rear DIP switch selection of relay On in or outside limits Rear DIP switch selection for 10 sec start-up delay Upper and lower limits separately adjustable LED indication for over / under frequency Latch facility incorporated Output 10A SPDT relay Input Specifications Input Pin 5 & 7 Measuring Ranges (5A 1-5A Lower limit 1-5A Internal Resistance Output Specifications Rated Isolation Voltage Upper limit Maximum Overload Current Output Specifications SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.1 10 A (30 sec) Nominal Rate in AC1 1500 VA ( Ag-Ni ) Measuring Ranges (1A Upper limit 0.2 - 1A Rated Current 10A Lower limit) 0.2 - 1A Rated Voltage 250V Internal Resistance Maximum Overload Current Hysteresis 5.6 5 A (30 sec) 5% Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption Mechanical Life Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED yellow LED yellow ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 53 WA5 Current Window Comparator Mode of Operation Under Limits Over Limits The relay will de-energize if the current drops below the set upper limit or exceeds the set lower limit. If the current increases by 5% of the set upper limit or decreases by 5% of the set lower limit the relay will de-energize. The relay will de-energize if the current exceeds the set upper limit or drops below the set lower limit. If the current reduces by 5% of the set upper limit or increases by 5% of the set lower limit the relay will energize, Example Protection for over current of equipment Example Detection of conveyor belt break. Wiring Diagram Operations Diagram 54 LP1 Pump Protection Relay (Single Phase) Description Microprocessor based pump protection relay capable of protecting a submersible pump against all major power line faults. The unit calibrates itself under normal running conditions and stores these parameters in non-volatile memory. The unit also incorporates a reset delay for under current situations to enable the borehole to replenish itself. In an over current situation the unit will retry three times to prevent permanent tripping with temporary blockages. FEATURES Microprocessor based protection relay Over / Under Current Protection Over / Under Voltage Protection Selectable Under Current Reset Delay Three retries for Over current Automatic Self Diagnosis of Pump Input Specifications Current Input Measuring Ranges Over Current Limit Recovery Time Pin 6 & 10 1 - 5A Output Specifications Output Specifications Rated Isolation Voltage 12% (17% extended 15 sec SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) (3attempts then permanent OFF) Under Current Limit Recovery Time Maximum Overload Current Voltage Input Measuring Range Over / Under Voltage Limit Hysteresis 8% (12% extended) 6hrs (Galvanic) Isolation Consumption 1500 VA ( Ag-Ni ) 10A (30sec Rated Current 10A Pin 1 & 2 Rated Voltage 250V 160 - 260VAC ± 15% (20% extended) 5% Supply Specifications Power Supply AC Type Nominal Rate in AC1 Mechanical Life Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA ± 6VA 525 V Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 55 LP1 Pump Protection Relay (Single Phase) Mode of Operation Voltage Monitoring Current Monitoring The unit starts monitoring current after the 6 sec start-up delay. If the current drops below the set parameter the unit will trip the pump for the DIP switch selectable recovery time. If the current rises above the set parameter, the unit will trip for ± 10 sec, after which the pump will restart. If an over current condition is detected three consecutive times the unit will trip permanently until the power is removed and reapplied. The unit monitors voltage continuously and will trip the pump if the voltage rises or drops below the set parameters. After the fault has corrected itself the unit will automatically restart the pump and resume normal operation. Example - Unit calibrated at 230 VAC without extending the parameters will trip at 258V and 202V. - The unit is calibrated at 225V with extended parameters. The unit will trip at 270V and 180V. Security Switch Trip The security switch should control all manual pump operations. Any monitoring equipment i.e. level controllers, pressure switches or time switches would be connected in series between contact 7 & 8. The pumps ON/OF control switch should also be connected in series to above contacts. Example - Unit calibrated at 25A with a 30/5 CT with extended parameters will trip at 29A and 22A. - A unit calibrated at 4.5A connected directly to the motor (no CT) without extending the parameters will trip at 5.27A and 3.96A. Star / Delta Connection If the pump connected to the Lp3 is a star/delta, contacts 8 & 9 must be closed until the delta contact comes in, after which the unit will start up as normal. This prevents any nuisance tripping in the transition between star and delta. Wiring Diagram 56 LP1 Pump Protection Relay (Single Phase) Operation Diagram 57 LP2 Pump Protection Relay (Single Phase) Description Microprocessor based pump protection relay capable of protecting a submersible pump against all major power lin faults. The unit calibrates itself under normal running conditions and stores these parameters in non-volatile memory. The unit also incorporates a reset delay for under current situations to enable the borehole to replenish itself. In an over current situation the unit will retry three times to prevent permanent tripping with temporary blockages. FEATURES Microprocessor based protection relay Over / Under Current Protection Over / Under Voltage Protection Selectable Under Current Reset Delay Three retries for Over Current Automatic Self Diagnosis of Pump LED indication for all faults Input Specifications Current Input Pin 6 & 10 Measuring Ranges 1 - 5A Over Current Limit 12% Recovery Time Output Specifications Output Specifications Rated Isolation Voltage 15 sec (17% extended) SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) (3attempts then permanent OFF) Under Current Limit Recovery Time Maximum Overload Current Voltage Input Measuring Range Over / Under Voltage Limit Hysteresis 8% (12% extended) 1, 2, 4, 8hrs 10A (30sec) Pin 1 & 2 160 - 260VAC ± 15% (20% extended) 5% Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 110, 230, 400V, 525V ± 10% 50 / 60 Hz ± 5Hz 4kV ± 3VA ± 6VA 525 V Nominal Rate in AC1 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications Power ON Delay 300 ms Power OFF Delay 200 ms Indication for Relay ON Power ON Over Voltage Under Voltage Over Current Under Current Security switch open LED green LED red ----------- Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 58 LP2 Pump Protection Relay (Single Phase) Mode of Operation Voltage Monitoring Current Monitoring The unit starts monitoring current after the 6 sec start-up delay. If the current drops below the set parameter the unit will trip the pump for the DIP switch selectable recovery time. If the current rises above the set parameter, the unit will trip for ± 10 sec, after which the pump will restart. If an over current condition is detected three consecutive times the unit will trip permanently until the power is removed and reapplied. The unit monitors voltage continuously and will trip the pump if the voltage rises or drops below the set parameters. After the fault has corrected itself the unit will automatically restart the pump and resume normal operation. Example - Unit calibrated at 230 VAC without extending the parameters will trip at 258V and 202V. - The unit is calibrated at 225V with extended parameters. The unit will trip at 270V and 180V. Security Switch Trip The security switch should control all manual pump operations. Any monitoring equipment i.e. level controllers, pressure switches or time switches would be connected in series between contact 7 & 8. The pumps ON/OF control switch should also be connected in series to above contacts. Example - Unit calibrated at 25A with a 30/5 CT with extended parameters will trip at 29A and 22A. - A unit calibrated at 4.5A connected directly to the motor (no CT) without extending the parameters will trip at 5.27A and 3.96A. Star / Delta Connection If the pump connected to the Lp3 is a star/delta, contacts 8 & 9 must be closed until the delta contact comes in, after which the unit will start up as normal. This prevents any nuisance tripping in the transition between star and delta. Wiring Diagram 59 LP2 Pump Protection Relay (Single Phase) Operation Diagram 60 LP3 Pump Protection Relay (Three Phase) Description Microprocessor based pump protection relay capable of protecting a submersible pump against all major power line faults. The unit calibrates itself under normal running conditions and stores these parameters in non-volatile memory. The unit also in corporate a reset delay for under current situations to enable the borehole to replenish itself. In an over current situation the unit will retry three times to prevent permanent tripping with temporary blockages. FEATURES Microprocessor based protection relay Over / Under Current Protection Over / Under Voltage Protection Phase Failure / Phase Reversal Protection Selectable Under Current Reset Delay Three retries for Over Current Automatic Self Diagnosis of Pump LED indication for all faults Input Specifications Current Input Pin 6 & 10 Measuring Ranges 1 - 5A Over Current Limit 12% (17% extended) Recovery Time Output Specifications Output Specifications Rated Isolation Voltage 15 sec SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) (3attempts then permanent OFF) Under Current Limit Recovery Time Maximum Overload Current Voltage Input Measuring Range Over / Under Voltage Limit Hysteresis 8% (12% extended) 1, 2, 4, 8hrs 10A (30sec) Pin 1, 2, 11 320 - 460VAC ± 15% (20% extended) 5% Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 110, 230, 400V, 525V ± 10% 50 / 60 Hz ± 5Hz 4kV ± 3VA ± 6VA 525 V Nominal Rate in AC1 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications Power ON Delay 300 ms Power OFF Delay 200 ms Indication for Relay ON Power ON Over Voltage Under Voltage Over Current Under Current Security switch open LED green LED red ----------- Environment Degree Of Protection IP 20 Operating Temperature -10 to + 50oC Storage Temperature -50 to + 85oC Weight 200g 61 LP3 Pump Protection Relay (Three Phase) Mode of Operation Voltage Monitoring Current Monitoring The unit starts monitoring current after the 6 sec start-up delay. If the current drops below the set parameter the unit will trip the pump for the DIP switch selectable recovery time. If the current rises above the set parameter, the unit will trip for ± 10 sec, after which the pump will restart. If an over current condition is detected three consecutive times the unit will trip permanently until the power is removed and reapplied. The unit monitors voltage continuously and will trip the pump if the voltage rises or drops below the set parameters. After the fault has corrected itself the unit will automatically restart the pump and resume normal operation. Example - Unit calibrated at 230 VAC without extending the parameters will trip at 258V and 202V. - The unit is calibrated at 225V with extended parameters. The unit will trip at 270V and 180V. Security Switch Trip The security switch should control all manual pump operations. Any monitoring equipment i.e. level controllers, pressure switches or time switches would be connected in series between contact 7 & 8. The pumps ON/OF control switch should also be connected in series to above contacts. Example - Unit calibrated at 25A with a 30/5 CT with extended parameters will trip at 29A and 22A. - A unit calibrated at 4.5A connected directly to the motor (no CT) without extending the parameters will trip at 5.27A and 3.96A. Star / Delta Connection If the pump connected to the Lp3 is a star/delta, contacts 8 & 9 must be closed until the delta contact comes in, after which the unit will start up as normal. This prevents any nuisance tripping in the transition between star and delta. Wiring Diagram 62 LP3 Pump Protection Relay (Three Phase) Operation Diagram 63 CP404 Pre-Select Counter Description The CP404 is a fully programmable microprocessor controlled four digit counter. The set value can be entered via the front membrane switch and the relay action and UP or DOWN count is set via rear DIP switches. The unit also incorporates a supply for a NPN proximity switch which can be used to pulse the counter. FEATURES Microprocessor based design Rear DIP switch selection of UP / DOWN count Rear DIP switch selection for relay ON when reaching count / relay PULSE when reaching count Front mounted membrane switch to select count 4 Seven segment displays (max. Count 9999) Power supply for 3 wire NPN proximity switch Permanent memory for selected count Reset facility incorporated Output 10A SPDT relay Input Specifications Probe Type NPN 3 wire proximity switch Pin 7 + supply Pin 8 - supply Pin 11 Probe Voltage Output Specifications Output Specifications Rated Isolation Voltage Probe input 24 VDC Nominal Rate in AC1 SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Short Circuit Current Response Time Reset Time Rest Input 25mA max 0.1 sec Rated Current 10A 1 sec Rated Voltage 250V Pin 8 & 9 Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Counter display Output ON 4 * 7 - segment red LED yellow ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 64 CP404 Pre-Select Counter Mode of Operation Setting Pre-Select Count Press the SET button once where after the first digit will flash. Adjust the value with the UP and DOWN button. When the correct value is displayed, press the SET button to move to the next digit. Repeat these steps until the last digit is set and press the SET button again to store the pre-select count. Counting UP When the supply is applied or the unit is reset, the display starts at 0000. The displayed will increment every time the input is activated until the pre-selected count is reach. Counting DOWN When the supply is applied or the unit is reset, the display starts at the pre-select count. The displayed will decrement every time the input is activated until the pre-selected count reaches 0000. Relay ON on reaching count This function energizes the relay on reaching count and remains ON until the supply is removed or the unit is reset. Relay Pulse on reaching count This function pulses the relay for 0.5 seconds on reaching count and resets the unit. More than one unit can be cascaded in this mode by pulsing the next unit. Example - Batch counting on conveyor belt - Total number of operations. Wiring Diagram Operations Diagram 65 TP404 Digital Timer (Multi-Function) Description The TP404 is a fully programmable microprocessor controlled four digit timer. The set value can be entered via the front membrane switch and the relay action and UP or DOWN timing is set via rear DIP switches. The unit can also be supplied in minute and hour ranges. FEATURES Microprocessor based design Rear DIP switch selection of Lapsed / Remaining time display Rear DIP switch selection for 999.9 / 9999 seconds Front mounted membrane switch to select count 4 Seven segment displays (max. Time 9999) Permanent memory for selected count Reset facility incorporated Output 10A SPDT relay Input Specifications Time Ranges Repeat Accuracy Time Variation within rated power Output Specifications 0 - 999.9 seconds Output Specifications 0 - 9999 seconds Rated Isolation Voltage ± 0.2% < 0.05% / V SPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) < 0.2% ºC supply and ambient Nominal Rate in AC1 temperature 1500 VA ( Ag-Ni ) Reset Time 500ms Rated Current 10A Reset Input Pin 8 & 9 Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Counter display Output ON 4 * 7 - segment red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 66 TP404 Digital Timer (Multi-Function) Mode of Operation Setting Pre-Select Count Press the SET button once where after the first digit will flash. Adjust the value with the UP and DOWN button. When the correct value is displayed, press the SET button to move to the next digit. Repeat these steps until the last digit is set and press the SET button again to store the pre-select time. This value is stored permanently in the unit, even after a power failure. Counting UP When the supply is applied or the unit is reset, the display starts at 0000. The displayed will increment every time the input is activated until the pre-selected count is reach. Counting DOWN When the supply is applied or the unit is reset, the display starts at the pre-select count. The displayed will decrement every time the input is activated until the pre-selected count reaches 0000. Relay ON on reaching count This function energizes the relay on reaching count and remains ON until the supply is removed or the unit is reset. Relay Pulse on reaching count This function pulses the relay for 0.5 seconds on reaching count and resets the unit. More than one unit can be cascaded in this mode by pulsing the next unit. Example - Precision timing Wiring Diagram Operations Diagram 67 PSU Power Supply Unit Description Power supply for low current DC regulated supplies. FEATURES Overload Protection Short-circuit Protection Over Temperature shut down Stable supply with low ripple factor Power supply ON LED Output Specifications General Specifications 5, 9, 10, 12, 24 VDC Power ON Delay 300 ms Output Power 2VA 10VA Power OFF Delay 200 ms Ripple Voltage < 2% < 2% Standard Output Voltage Overload Protection Indication for Power Supply ON yes LED red yes Environment Degree Of Protection -10 to + 50oC Storage Temperature -50 to + 85oC Weight Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption IP 20 Operating Temperature 200g Wiring Diagram 110, 230, 400V, 525V ± 10% 50 / 60 Hz ± 5Hz 4kV ± 3VA ± 6VA 525 V 68 SSF2 Solid State Flasher Description The solid state flasher is designed to eliminate mechanical wear and tear and arcing when switching incandescent lamps continuously. The unit also has selectable interval timing for warning signals. FEATURES Microprocessor based design 90 Flashes per second Triac output 5A 1000W/250V Selectable Internal timing Two complementary output 95 - 230VAC supply Input Specifications Time Ranges Range Accuracy Repeat Accuracy 90 pulses per second < 1% Output Specifications Output Specifications Rated Isolation Voltage ± 0.2% ± 0.2% Rated Current Time Variation < 0.5% / V within rated power < 0.5% / ºC supply and ambient 90 pulses per second < 1% < 0.5% / V Rated Voltage Mechanical Life < 0.5% / ºC Electrical Life temperature Operation Frequency Reset Time Supply Specifications Power Supply AC Type (Galvanic) Isolation Consumption 800ms 800ms 110, 230, 400V, 525V ± 10% 50 / 60 Hz ± 5Hz 4kV ± 3VA General Specifications Environment Degree Of Protection Operating Temperature Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g ± 6VA 525 V Wiring Diagram 69 THC1 Two Hand Control Modules Description The unit is designed for machines where the operator has to push two buttons to activate the machine itself (two hand control). A latch facility is incorporated to use with a foot switch. FEATURES Two normal open inputs for two hand control Latch input for foot control Fixed time to activate both hand control Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation Two hand control modular Both buttons (No contacts) must be pushed within a fixed time (0.5s) to activate the output relay. If one is released, the relay de-energizes instantaneously. To activate the relay is necessary to release also the other button and then push both contemporary. When both buttons are pushed, the output relay can be latched by closing an external contact (terminals 4-7), in this case the output relay de-energizes only by opening the latch or pushing one of the buttons. If both buttons are closed when the unit is powered up, the relay energizes instantaneously. Example - Two hand control for safety reasons Wiring Diagram Operation Diagram 70 FRT1 Forward / Reverse Timer Description Forward reverse timer controls two circuits which are activated separately and are switched after a adjustable pause time. FEATURES Separate Forward and Reverse outputs Separate adjustable ON and OFF time Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation Pump Sequence module When power is applied to the unit contacts 1 & 4 close for the preset ON time range. After the ON time has expired an adjustable OFF time is activated where both contacts 1, 3 & 4 are open. After this contacts 1 & 3 are closed for the adjustable ON time and the cycle continues with the adjustable OFF time. Example - Controlling washing machine cycles (forward and reverse) Wiring Diagram Operation Diagram 71 PSR1 Pump Sequence Relay Description Pump sequence module is designed to optimize the wear on pumps, compressors or generators. The first input energizes the first pump and stores this in non-volatile memory. Subsequent inputs will energize the next output. The number of inputs correspond to the number of outputs. After power down or no inputs activated and an input is activated, the next in the sequence of outputs is activated. This ensure balanced usesage of the pumps because the same pump is not activated at the beginning of a sequence. FEATURES Three normally open pressure switch inputs (voltage free) Three normally open pump outputs Permanent memory for next pump activated after power off Output 10A SPDT Mode of Operation Pump Sequence Module Closure of the first pressure switch the first pump will be energized. The second and third pressure switch will energize the second and third pump. The number of pumps activated correspond to the number of pressure switches closed. If switch 2 opens the second pump will de-activate. The position of the switches does not matter, just the number. If all switches are open no pump is activated, and the next switch closed will activate the second pump. The next switch will activate the third pump. This ensures a spread of the work load between pumps. Example - Controlling washing machine cycles (forward and reverse) Wiring Diagram Operation Diagram 72 PSP1 Pump Seal Protection Relay Description Microprocessor based monitoring relay to measure moistur e in a submersible pump. Due to the advanced design of the unit a high accuracy and safety is achieved. Respons e delay are incorpor ated to prevent nuisance tri pping. The unit energi ses on application of supply. If the current thro ugh the probes is more than 20uA or the resistance is smaller then 1Mohm, the relay will de-energise after 10 sec. The relay will energi se if the current is less the 15uA and the resistance is more then 1.4Mohm. FEATURES Microprocessor based design High accuracy analogue converter Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Sensor Input Specifications Sensitivity (A) Sensitivity (Ohm) Response time 15uA - 20uA 1Mohm - 1.4Mohm 10Sec Output Specifications Output Specifications Rated Isolation Voltage Supply Specifications Power Supply AC Type 110, 230, 400V, 525V ± 10% (Galvanic) 50 / 60 Hz ± 5Hz 4kV Isolation ± 3VA Consumption ± 6VA 525 V 12,24,48 V ± 10% Power Supply DC Types 6000 VAC (contact / electric) 1000 VAC (contact / contact) 1500 VA ( Ag-Ni ) Rated Current 10A Rated Voltage 250V Mechanical Life Electrical Life Operation Frequency (Non-galvanic) 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h None Isolation ± 100 mA Consumption Wiring Diagram General Specifications Power ON Delay 300 ms Power OFF Delay 200 ms 1 Indication for 3 Power Supply ON Output ON 4 Supply Nominal Rate in AC1 DPDT 2 10 5 LED red LED green Environment Degree Of Protection Operating Temperature Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 7 PSP1 77 SC120 Signal Converters Description Compact signal convert er with built-in 24VDC power supply for the output. The unit is designed for low amplitude signals where isolation is not needed (use SI100 for isolat ion). A variety of inputs and outputs are avail able to suit most applications. FEATURES High linearity Sink or Source On-board PSU Choice of Inputs and Outputs Low cost Versatile Power supply ON LEDs Input Specifications Input Signals Output Specifications 4-20mA 0-20mA 0-5Vdc 0-10Vdc Output Specifications 4-20mA 0-20mA 0-5Vdc 0-10Vdc Input loading Input dependent Tracking accuracy ±0.5% Supply Specifications Output Impedance Power Supply AC Type (Galvanic) Isolation Consumption 110, 230, 400V, 525V ± 10% 50 / 60 Hz ± 5Hz 4kV 250ohm for 20mA/5V 500ohm for 20mA/10V Output Drive voltage Tracking accuracy 24Vdc (30mA) <0.5% FS ± 3VA ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Wiring Diagram 1 None ± 100 mA General Specifications Power ON Delay 300 ms Power OFF Delay 200 ms Indication for Power Supply ON LED red Environment 3 + 4 - Volt out Degree Of Protection Operating Temperature 5 Storage Temperature Input 6 Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 7 2 Supply 10 11 9 - 8 + I out 78 SI100 Signal Isolator Description Compact signal isol ator with buil t-in 24VDC power supply for the output. The unit is designed for high isolationbetween input, output and supply. A variety of inputs and outputs are avail able to suit most applications. FEATURES High linearity Sink or Source On-board PSU Choice of Inputs and Outputs Low cost Versatile Power supply ON LEDs Input Specifications Output Specifications SC120A 0-1A 0-5A 4-20mA 0-20mA Input Signals SC120V 0-600Vac 0-300Vac 0-10Vdc 0-5Vdc Output Specifications 4-20mA 0-20mA 0-5Vdc 0-10Vdc Input loading Input dependent Tracking accuracy ±0.5% Supply Specifications Output Impedance Power Supply AC Type 110, 230, 400V, 525V ± 10% (Galvanic) 50 / 60 Hz ± 5Hz 4kV Isolation 250ohm for 20mA/5V 500ohm for 20mA/10V Output Drive voltage Tracking accuracy 24Vdc (30mA) <0.5% FS ± 3VA Consumption ± 6VA 525 V 12,24,48 V ± 10% Power Supply DC Types (Non-galvanic) None Isolation ± 100 mA Consumption 1 300 ms 200 ms Indication for LED red Environment 3 + 4 - 5 + Volt out Degree Of Protection Operating Temperature Storage Temperature Input 6 7 Supply Power ON Delay Power OFF Delay Power Supply ON Wiring Diagram +24 Vout General Specifications Weight IP 20 -10 to + 50oC -50 to + 85oC 200g Common 2 10 11 9 - 8 + I out 79 ECONO RANGE T10 On-Delay Timer Description The T10 is an economical single function, single time range timer. FEATURES Single function / single time range / single voltage Potentiometer adjustable time setting Repeatable deviation: < 1% Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation On Delay When applying supply the relay is de-energized and timing starts. The relay only energizes after the set time is elapsed and will remain so until the supply is removed. Example - Delaying energization of a load on applying power. Wiring Diagram Operation Diagram 73 ECONO RANGE T1I Interval Timer Description FEATURES Single function / single time range / single voltage Potentiometer adjustable time setting Repeatable deviation: < 1% Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation Interval When applying the supply the relay is energized and remains so until the set time is elapsed. The relay will then de-energize until the supply is removed and re-applied. Example - Energization of a load for a set time period. Wiring Diagram Operation Diagram 74 ECONO RANGE R1E Equal Repeating Description FEATURES Single function / single time range / single voltage Potentiometer adjustable time setting Repeatable deviation: < 1% Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation Interval When applying supply the set OFF time period is activated where after an equal ON time begins. This cycle is repeated until the supply is removed. Example - Switching a load on and off repetitively in equal intervals. Wiring Diagram Operation Diagram 75 ECONO RANGE T1I/P Pulse Controlled Interval Timer Description FEATURES Single function / single time range / single voltage Potentiometer adjustable time setting Repeatable deviation: < 1% Power supply ON and Relay ON LEDs Output 10A SPDT Mode of Operation Pulse Controlled Interval Permanent supply is applied to the unit. When closing contacts 6 & 7 the relay energizes for the set time period. The relay then de-energizes until contacts 6 & 7 are closed again. Example - Delaying release after limit switch operation. Wiring Diagram Operation Diagram 76 PT11 / PT13 Electronic Reset Timer Description Microprocessor based Multi-function timer with four selectable functions and time ranges from 0.3sec - 60hrs. The unit interfaces with standard NPN (PT11) or PNP (PT13) proximity sensors. Extensive applications due to combination of functions and time ranges. Due to the advanced design of the unit a high accuracy can be achieved. All commonly used functions are incorporated in the unit. FEATURES Microprocessor based design Time range 0.3sec - 60hrs Interfaces with NPN (PT11) or PNP (PT13) proxy Rear DIP switch selection of 4 function Rear DIP switch selection of 4 timer ranges Potentiometer adjustable time setting Repeatable deviation: < 0.2% Power supply ON and Relay ON LEDs Output 5A DPDT Time Specifications Time Ranges Range Accuracy Scale Accuracy Repeat Accuracy Time Variation within rated power supply and ambient temperature Reset Time Pulse Duration Output Specifications 0.3 - 6sec 3 - 60 sec 0.3 - 6min 3 - 60 min (Galvanic) Isolation Consumption Rated Isolation Voltage DPDT 6000 VAC (contact / electric) 1000 VAC (contact / contact) 0.5% 5% Nominal Rate in AC1 1500 VA ( Ag-Ni ) 0.2% 0.05% / V 0.2% / oC Rated Current 5A Rated Voltage 250V Mechanical Life 500 ms 100 ms (pin 5) Supply Specifications Power Supply AC Type Output Specifications Electrical Life Operation Frequency 6 10x10 cycles 3 110x10 cycles (at max load) 1800 cycles/h General Specifications 110, 230, 400V, 525V ± 10% Power ON Delay 300 ms 50 / 60 Hz ± 5Hz Power OFF Delay 200 ms 4kV ± 3VA Indication for Power Supply ON Output ON LED red LED green ± 6VA 525 V Power Supply DC Types 12,24,48 V ± 10% (Non-galvanic) Isolation Consumption Environment Degree Of Protection Operating Temperature None ± 100 mA Storage Temperature Weight IP 20 -10 to + 50oC -50 to + 85oC 200g 84 PT11 / PT13 Electronic Reset Timer Mode of Operations Function 1: Delay On Operate, Hold Reset Function 2: Delay On, Pulse Reset When applying supply the relay remains de-energized until reset occurs. When the reset contact is released, the timer starts running and the relay energises when the set time has elapsed. When the reset contact closes again, the relay release and the timer assumes a “ reset and hold” mode. When the reset contact releases, the timer starts running and the relay remains off until the set time has elapsed when the relay will energise. Example When applying supply, the relay remains de-energised until the reset occurs. When the reset contact closes, the timer starts running and the relay energises when the set time has elapsed. When the reset contact closes again, the relay de-energises and the timing starts immediately regardless of pulse duration.The relay energises after the set time has elapsed. Example Safety operation on door closure Function 3: Interval, Hold Reset Access boom control Function 4: Interval, Pulse Reset When applying supply the relay remains de-energised until the reset occurs at which point the relay energises and the timer assumes a “reset and hold” mode. When the reset contact Example When applying supply the relay remains de-energised until the reset occurs at which point the relay energises and the timer starts running regardless of the pulse duration. The relay deenergises when the set time has elapsed. Example Automatic start of backup systems Conveyor belt break detection Wiring Diagram 1 1 3 3 4 4 11 11 9 9 8 8 2 2 Supply Supply 10 10 5 5 PNP Proxy + - NPN Proxy + 6 PT11 - 7 6 PT13 7 Operations Diagram Function 1: Delay On Operate, Hold Reset Function 2: Delay On, Pulse Reset Power supply Power supply Pulse 5 Pulse 5 t t Relay On Function 3: Interval, Hold Reset Function 4: Interval, Pulse Reset Power supply Power supply Pulse 5 Relay On t t t Relay On Pulse 5 t t t Relay On t t t t 85