HC706 CONTACT OUTPUT UNIT
INFRARED
SENSOR
INDICATORS
When the battery becomes low, the green light
will turn off but will blink on every two and a
half seconds. When the battery becomes
exhausted, the unit will fail to operate.
TEST BUTTON
To use this button to manually turn an output
on or off, proceed as follows:-
The HC706 will have been set up to suit the
programming of your main controller (Compact,
Companion or Freeway).
To control the device(s) connected to the
HC706, simply select the appropriate position
from your controller menu.
The outputs of the HC706 may be set up to
operate in many different ways. The engineer
will have explained how your system works at
the time of installation.
• Hold the button in. After a short delay,
any outputs which are on will be turned off.
• After a second or so, Channel A will turn
on.
• Next, Channel A will turn off and Channel B
will turn on.
• Finally after a further delay, both channels
will turn on.
There are 3 indicator lights on the front panel.
The 2 orange Channel lights show when the
outputs are activated.
The green Status light indicates when mains
power is present and the state of the internal
battery.
When the mains power is on, the green light
should be on all the time.
When the mains power is removed and the unit
is operating from its internal battery, the green
light will blink off every two and a half seconds.
If the green Status light is on continuously, go
to step 2.
1.
Check that the mains plug has not been
removed from the wall socket and that
power is present at the socket. If the
green Status light is still not on, contact
Possum Controls Ltd.
2.
Press and hold in the TEST BUTTON,
as already described. If the orange
Channel lights do NOT operate correctly,
contact Possum Controls Ltd.
3.
Check that there is nothing between your
controller and the sensor on the HC706
unit, which could stop the infrared
signals from being picked up by the unit.
4.
If your installation includes a remote
infrared sensor, ensure that the remote
sensor is still mounted where the
engineer installed it and has not fallen
down or turned away.
5.
Check that the path between your
controller and the remote sensor is clear.
There is a button located in the recess on
the underside of the unit which may be used
to manually operate the outputs and to test
the unit.
MANUAL
BUTTON
INDICATOR LIGHTS
IF YOU HAVE A PROBLEM
If the button is still held, both outputs will be
turned off after 1 second and the sequence
will then repeat at 1 second intervals while
the button is held in.
To set the unit to a particular output state,
just release the button when the orange
Channel indicator lights show the required
states.
BUZZER
The HC706 unit contains a buzzer which may
have been set up to sound when one or more
outputs are operated. This buzzer may also
be set up to warn of a mains failure.
NOTE: If a remote sensor is installed,
there will be a cable fitted in the third
hole from the right, on the underside.
If you are still unable to solve the problem,
please contact Possum Controls Ltd. at the
address overleaf for assistance.
HC706
POSSUM CONTROLS LIMITED
8, FARMBROUGH CLOSE
STOCKLAKE PARK INDUSTRIAL ESTATE
AYLESBURY
BUCKS.
HP20 1DQ
SCOPE OF USE
The HC706 Contact Output Unit is classified as a Class 1 (low
risk) medical device, intended for use by physically disabled
persons to control appliances or equipments in a domestic
environment. The unit may also be used within nursing homes
and hospitals, providing adequate care is taken to ensure the
safety of each particular installation.
Possum Controls Limited products are not authorised for use
as critical components in life support devices or systems which
sustain life and whose failure to perform, when properly used
in accordance with the instructions for use provided, can
reasonably be expected to result in significant injury or death.
A critical component is any component of a life support device
or system whose failure to perform can reasonably be expected
to cause the failure of the life support device or system or to
affect its safety or effectiveness.
APPROVALS
TELEPHONE
FAX
email
WEBSITE
01296 461000
01296 461001
sales@possum.co.uk
http://www.possum.co.uk
Notice
Possum Controls Limited reserves the right to make
improvements to this guide or the products it describes
at any time and without further notice. This guide is
copyright in the U.K. and all rights are reserved. No
part of this guide or the product it describes may be
reproduced by any means or in any forms, without prior
consent in writing from Possum Controls Limited.
HC706 User Guide - part number: 034-122 Iss:3
 Possum Controls Limited, November 2003
CONTROLS LIMITED
The Possum HC706 Infrared Controlled Contact Output
Switching Unit is CE marked under the Medical Devices
Directive 93/94/EEC (as an accessory to a Possum
Compact, Companion or Freeway Controller)and has been
tested and approved to the following standards:
EN60601-1-1 (electrical safety)
EN60601-1-2 (electro-magnetic compatibility)
This equipment does generate, use and can radiate radio
frequency energy and if not installed correctly, may cause
interference with radio and television receivers or other
sensitive equipment. This equipment may be susceptible to
radio frequency energy or mains conducted interference
generated by other nearby equipment. Interference is
unlikely to be a problem in a typical domestic environment
but if you have any queries please contact Possum Controls
Limited for advice.
SERVICING
There are no user-serviceable parts within the Possum
HC706. Refer all faults to Possum Controls Limited or their
authorised service agents.
Note that under the Medical Devices Directive, only service
personnel trained and approved by Possum Controls Limited
are permitted to install, maintain and repair this product.
WARNING! Hazardous mains voltages and exposed live
parts exist within the HC706 unit when in use. Never attempt
to open the unit or remove the case cover.
INTERNAL BATTERY PACK
The HC706 contains a Nickel-Cadmium battery pack.
Cadmium is a highly toxic substance.Do not mutilate or short
circuit the battery pack. All battery packs should be returned to
Possum Controls Limited for controlled disposal.
CONNECTING EXTERNAL EQUIPMENT
Only service engineers or electricians trained and approved by
Possum Controls Limited are permitted to connect any wiring or
other equipment to the HC706 or its accessories.
1.
2.
3.
4.
5.
6.
PRODUCT CARE
Switch off or disconnect the mains supply to the HC706
unit before attempting to clean the product.
The Possum HC706 should be cleaned only with a soft,
lint-free cloth slightly moistened with clean water.
Do not use abrasive or solvent-based cleaning products.
Do not allow moisture to enter the HC706 unit. Ensure
that the product is dry before re-connecting to the mains
supply.
The Possum HC706 is intended for indoor use only and is
not drip proof, splash proof or waterproof.
The Possum HC706 is not anaesthetic proof and cannot
be sterilised.
SPECIFICATIONS
POWER REQUIREMENTS
The Possum HC706 is designed to operate from a domestic
mains supply of 216V to 253VAC 50Hz, 25mA maximum.
OPERATING ENVIRONMENT
Operating Temperature Range:
Operating Humidity Range:
Operating Altitude Range:
5°C to 40°C
(41°F to 104°F)
30% to 75%
(non-condensing)
0m to 2,000m
STORAGE ENVIRONMENT
Storage Temperature Range:
Storage Humidity Range:
Storage Altitude Range:
0°C to 40°C
(32°F to 104°F)
30% to 75%
(non-condensing)
0m to 2,000m
WEIGHT AND PHYSICAL DIMENSIONS
Width:
Height:
Depth:
Weight:
180mm
116mm
48mm
1.15kilogrammes
Download