REN2LED LED Retrofit Kit Technical Specifications R LED The REN2LED is an energy efficient LED retrofit kit designed to convert existing fluorescent vaportight fixtures using SLP’s Citadel II enclosures. Easily update parking garage, canopy, food processing, cold storage, and other fixtures to efcient, long-lasting LED technology. Add years of maintenance-free life to the installation and restore their new look with replacement lenses. Pr ojec t C at alog N um ber Ty pe D at e Standard Distribution • Energy efficient – up to 28% energy savings vs. fluorescent • 72,000 hour operating life (L70) for maintenance savings • Control friendy, 0-10V dimming, standard LEDS 4' kits available in 3 light levels (delivered): 3600 lumens (46W), 4900 lumens (56W), and 7600 lumens (92W). 8' kits are available in 2 light levels (delivered): 7200 lumens (92W), and 9700 lumens (125W). LEDs are 4100K CCT, >80 CRI standard. Other color temperatures available; consult factory for lead times. LED operating life is up to 85,000 hours (L70). LEDs are LM-80 tested. Light engines consist of 128, 256, or 512 LED multi chip packages mounted to metal core PC boards. GEAR TRAY Gear tray to be die-formed, heavy gauge steel with high-gloss, baked white polyester finish over rust inhibiting phosphate coat. REN2 LED units are standard with LED boards mounted to flat gear tray. Angled gear trays for wide-angle distribution are available. Gear tray functions as heat sink. Wide Distribution WARRANTY 5 year limited warranty when installed in SLP CT2 housings. ELECTRICAL High efficiency LED power supply 120V-277V operation. Power factor >0.9. 0-10V dimmable. One power supply used in 46W and 56W kits. Two power supplies used in 92W and 125W kits. Power supply output current is 1500 mA (46W and 92W kits) and 2100 mA (56W and 125W kits). RoHS LED COMPLIANT FLUORESCENT HID CFL INDUCTION MADE IN THE UNITED STATES REN2 LED Retrofit Kit Ordering Information SERIES REN2LED SIZE 4 = 4' 8 = 8' GEAR TRAY/DISTRIBUTION F = Standard P = Wide WATTAGE/OUTPUT COLOR 4' UNITS ONLY 35 = 3500K 46 = 46W / 3600 Lumens* 41 = 4100K (standard) 56 = 56W / 4900 Lumens* 50 = 5000K 4' AND 8' UNITS 92 = 92W / 7200 Lumens* 8' UNITS 125 = 125W / 9700 Lumens* VOLTAGE U1 = 120-277 ACCESSORIES RFA4 = 4' ribbed frosted acrylic lens (for F geartray) RFA8 = 8' ribbed frosted acrylic lens (for F geartray) DFA4 = 4' deep frosted acrylic lens (for P geartray) DFA8 = 8' deep frosted acrylic lens (for P geartray) ELS = Emergency Power Supply (Consult factory) *Estimated delivered lumens are with new lens, will vary with condition of existing fixture lens. FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 01292015 REV 2.0 (800) 523-3602 • www.simkar.com LED REN2LED LED Retrofit Kit Technical Specifications Dimensions 53⁄64” DIA 27⁄32” 4 13⁄32” 5 ¾” 1 13⁄32” 6 ¾”; with latches 7 11⁄32” (RFA) Deep Lens (DFA) 5 13⁄32 ” 5 13⁄32” Reference - 8' models 1 13⁄16” LED Board LED Board 43 5⁄16” CL Slot - CL Slot 98” 50 13⁄64” 50” 37 13⁄32” CL Slot - CL Slot 37 13⁄32” CL Slot - CL Slot 46 ½” 43 5⁄16” CL Slot - CL Slot 1” Edge - Edge of Slot 5 45⁄64” Edge - CL Slot 1” Edge - Edge of Slot 1” Edge - Edge of Slot Distance 2 45⁄64” CL Slot - Edge 5.3 6 5⁄16” Edge - CL Slot 6 13⁄32” Edge - CL Slot 1 51⁄64” 2 11⁄16” Distance from CL of Slot to Edge FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 01292015 REV 2.0 2 5⁄8” Distance from CL of Slot to edge (800) 523-3602 • www.simkar.com REN2LED LED Retrofit Kit Technical Specifications REN2 LED Retrofit Kit Performance Model Fixture Length Input Power Light Output* Equivalent Fluorescent/HID1 Lumens / Watt Lens REN2LED4F4641U1 4' 46W 3600 Lumens 78.2 (2) 32WT8 or (2) 28WT5 Fluorescent Ribbed Frosted Acrylic REN2LED4F5641U1 4' 56W 4900 Lumens 87.5 (2) 32WT8, (2) 28WT5 or 150-175W Metal Halide Ribbed Frosted Acrylic REN2LED4F9241U1 4' 92W 7600 Lumens 78.2 (2) 54WT5HO Fluorescent Ribbed Frosted Acrylic REN2LED8F9241U1 8' 92W 7600 Lumens 78.2 (4) 32WT8 Fluorescent Ribbed Frosted Acrylic REN2LED8F12541U1 8' 125W 9700 Lumens 77.6 (4) 54WT5HO Fluorescent Ribbed Frosted Acrylic *Estimated delivered lumens with ribbed frosted acrylic lens and standard gear tray and will vary with condition of existing fixture lens. 1 Consult a lighting engineer to meet specific requirements. Projected LED Lumen Maintenance Operating Hours Lumen Maintenance Factor 0 25,000 50,000 85,000 1.0 0.93 0.83 0.72 Projected Lumen Maintenance data refers to extrapolated performance projections for REN2 LED platform in a 25˚ C ambient environment based on 10,000 hours of LED testing per IESNA LM80-08 and projected per IESNA TM-21-11. Photometric Data REN2LED4F5641U1 180 150 LUMINANCE SUMMARY CD./SQ.M. ZONAL LUMENS AND PERCENTAGES 120 ACROSS 45 ALONG 90 450 60 ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LUMENS 1144 1941 3614 4701 2760 1087 275 4976 % LUMINAIRE 22.99 39.01 72.64 94.48 55.47 21.84 5.52 100.00 ANGLE 45 55 65 75 85 ALONG 6077 5655 4503 2952 1816 45 6628 7241 4463 3732 2625 ACROSS 7889 5499 4463 3272 2451 S/MH: 1.7 SC Along: 1.2 SC Across 1.7 EFFICACY (LUMENS PER WATT): 89.5 900 1350 0 30 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 01292015 REV 2.0 (800) 523-3602 • www.simkar.com