SERIES CL - CK - Contactors

advertisement
SERIES CL - CK - Contactors
Contactors Series CL
�
�
�
�
�
A=AC
D=DC
E=DC/AC with electronic module
�
�
Type
identification
�
�
➀ Contactor (see K.11)
➁ Auxiliary contacts side-mounted (see K.15)
➂ Mechanical interlock (see K.15)
➃ Auxiliary contacts front-mounted (see K.15)
➄ Electronic timer block (see K.16)
➅ Transient voltage suppressor block (see ie K.16)
➆ Mechanical latch block (see K.15)
➇ Pneumatic timer block (see K.15)
➈ Thermal overload relay (see K.22)
�
C
Housing
00 05
01 06
02 07
25 08
03 09
04 10
45
Auxiliary
contacts NO
Auxiliary
contacts NC
Control voltage
L
3 = 3-pole
4 = 4-pole NO
B = 4-pole 2NO + 2NC
T = screw terminal
M = double clamp
terminal
Contactors Series CK
Type
identification
C
A=AC
E=DC/AC with electronic module
Housing
07 10
75 11
08 12
85 13
09
95
Auxiliary
contacts NO
Auxiliary
contacts NC
Control voltage
K
Version
(B, C)
3 = 3-pole
4 = 4-pole (4NO)
Thermal overload relay RT
Type
identification
R
Setting range (A...W)
T
Housing
2
= class 10A (RT1)
class 10 (RT2, RT3, RT4, RT5, RT6)
= class 20 (RT1. RT2. RT3)
L
= class 30
–
(RT4, RT5, RT6)
K
5
SERIES CL - Contactors
Three-pole contactors
from 9 to 105A (AC3)
– Power circuit (AC): up to 690V
– Control circuit:
Alternating current up to 690V AC
– Terminal numbering in accordance with
EN 50005 and EN 50012
– Fixing by clipping onto 35 mm DIN rail
EN 50022-35 or by screws
– Degree of protection CL00... to CL02... : IP20
CL25... to CL10... : IP10
– Screws protected against accidental contact in
accordance with VDE 0106.
– Three coil terminals.
– Accessories:
Mounting possibilities of front/side
instantaneous auxiliary contact blocks, timed
auxiliary contact blocks, mechanical latch,
transient suppressor block and interface
modules
– Maximum number of auxiliary contacts:
four for CL00...CL25
six for CL03...CL45
eight for CL06...CL10
CL00A310TN
CL45A300MN
Control circuit: alternating current
Max. operat. current
Noninductive
load
Elec. endur. Aux. contacts Cat. no.(1)
Admissible power AC3
Motors
220V 380V 415V 500V
≤ 440V
230V 400V 440V
3-phase
50/60 Hz
AC3
Category
AC3
A
A
kW
kW
kW
kW
# ops.
25
9
2.2
4
4
5.5
25
12
3
5.5
5.5
32
18
4
7.5
45
25
7.5
45
25
60
•3
•1
•4
•2
2 x 106
0
1
0
0
0
1
CL00A300T ◆
CL00A310T ◆
CL00A301T ◆
10
10
10
0.280
0.295
0.295
7.5
2 x 106
0
1
0
0
0
1
CL01A300T ◆
CL01A310T ◆
CL01A301T ◆
10
10
10
0.280
0.295
0.295
7.5
10
1.7 x 106
0
1
0
0
0
1
CL02A300T ◆
CL02A310T ◆
CL02A301T ◆
10
10
10
0.280
0.295
0.295
11
11
15
2 x 106
0
1
0
0
0
1
CL25A300T ◆ 10
CL25A310T ◆(2) 10
CL25A301T ◆(2) 10
0.270
0.285
0.285
7.5
12
12
15
2 x 106
1
0
0
1
CL03A310M ◆
CL03A301M ◆
10
10
0.490
0.490
32
9
16
16
18.5
2 x 106
0
1
0
0
0
1
CL04A300M ◆
CL04A310M ◆
CL04A301M ◆
10
10
10
0.500
0.520
0.520
60
40
11
18.5
22
25
2 x 106
0
1
0
1
CL45A300M ◆ 10
CL45A311M ◆(3) 10
0.490
0.540
90
50
15
22
25
30
1.8 x 106
0
1
0
1
CL06A300M ◆ 1
CL06A311M ◆(3) 1
1.075
1.105
110
65
18.5
30
37
40
1.7 x 106
0
1
0
1
CL07A300M ◆ 1
CL07A311M ◆(3) 1
1.090
1.120
110
80
22
37
45
45
1.5 x 106
0
1
0
1
CL08A300M ◆ 1
CL08A311M ◆(3) 1
1.110
1.130
140
95
25
45
50
55
1.7 x 106
0
1
0
1
CL09A300M ◆ 1
CL09A311M ◆(3) 1
1.000
1.450
140
105
30
55
55
65
1.5 x 106
0
1
0
1
CL10A300M ◆ 1
CL10A311M ◆(3) 1
1.440
1.470
LB1A◆
LB3A◆
LB4A ◆
0.063
0.102
0.145
AC1
Spare coils
Alternating current
CL00 - CL25
CL03 - CL45
CL06 - CL10
Available coil voltages (1)
Alternating current (V)
CL07A300MN
◆
C
50Hz
60Hz
D
F
G
J
K
M
24 42 48 110 127
24
48
120
N
R
U
220 240 380
230
400
220 277
V
W
X
480 440 460
◆
1
50/60Hz
24 42 110 120 220 230 240 440 48
115
2
3
4
5
6
7
8
Y
Z
415 440 500 660
690
Alternating current (V) Dual-frequency coil
9(4)
(1) To complete the catalogue number, replace the symbol ◆ by the code
corresponding to the voltage and frequency of the control circuit.
(2) Equipped with one block BCLF (see K.16)
(3) Equipped with two blocks BCLF (see K.16)
(4) Only for CL00 to CL45
Thermal overload relay, see K.22
Technical specifications, see K.35
Dimensions, see K.45
Pack Weight
600
5
5
5
SERIES CL - Contactors
Three-pole contactors
from 9 to 105A (AC3)
– Control circuit :
Direct current up to 440V
– Terminal numbering in accordance with
EN 50005 and EN 50012
– Fixing by clipping onto 35 mm DIN rail
EN 50022-35 or by screws
– Degree of protection CL00... to CL02... : IP20
CL25... to CL10... : IP10
– Screws protected against accidental contact in
accordance with VDE 0106.
– Three coil terminals.
– The types CL...E are also suitable for AC
control.
– Accessories:
Mounting possibilities of front/side
instantaneous auxiliary contact blocks, timed
auxiliary contact blocks, mechanical latch,
transient suppressor block and interface
modules
– Maximum number of auxiliary contacts:
four for CL00...CL25
six for CL03...CL45
eight for CL06...CL10
CL00D310TD
Control circuit: direct current
Max. operat. current
Noninductive
load
Elec. endur. Aux. contacts Cat. no.(1)
Admissible power AC3
Motors
220V 380V 415V 500V
≤ 440V
230V 400V 440V
3-phase
50/60 Hz
AC3
Category
AC3
A
A
kW
kW
kW
kW
operations
25
9
2.2
4
4
5.5
25
12
3
5.5
5.5
32
18
4
7.5
45
25
7.5
45
25
60
Pack Weight
•3
•1
•4
•2
2 x 106
1
0
0
1
CL00D310T ◆
CL00D301T ◆
5
5
0.490
0.490
7.5
2 x 106
1
0
0
1
CL01D310T ◆
CL01D301T ◆
5
5
0.490
0.490
7.5
10
1.7 x 106
1
0
0
1
CL02D310T ◆
CL02D301T ◆
5
5
0.490
0.490
11
11
15
2 x 106
0
0
CL25D300T ◆
5
0.480
7.5
12
12
15
2 x 106
1
0
0
1
CL03D310M ◆
CL03D301M ◆
10
10
0.480
0.480
32
9
16
16
18.5
2 x 106
1
0
0
1
CL04D310M ◆
CL04D301M ◆
10
10
0.835
0.835
60
40
11
18.5
22
25
2 x 106
0
0
CL45D300M ◆
10
0.825
90
50
15
22
25
30
1.8 x 106
0
0
CL06E300M ◆
1
1.095
110
65
18.5
30
37
40
1.7 x 106
0
0
CL07E300M ◆
1
1.110
110
80
22
37
45
45
1.5 x 106
0
0
CL08E300M ◆
1
1.120
140
95
25
45
50
55
1.7 x 106
0
0
CL09E300M ◆
1
1.440
140
105
30
55
55
65
1.5 x 106
0
0
CL10E300M ◆
1
1.460
LB1D ◆
LB3D ◆
LB4E ◆
5
5
1
0.205
0.276
0.610
AC1
Spare coils
(pure DC coil)
(pure DC coil)
(coil + electronic module)
CL00 - CL25
CL03 - CL45
CL06 - CL10
Available coil voltages (1)
Direct current (V). For contactors type CL...D / Operating limits: 0.80 ... 1.10 x Us
◆
B
Voltage
12 24 36 42 48 60 72 110 120 220 230 240
125
440
D
E
F
G
H
I
J
K
N
P
R
X
Direct current (V). Coil with electronic module for contactors CL...E (˝) / Operating limits: 0.80 ... 1.10 x Us
For contactors with WIDE VOLTAGE RANGE
only (0.70 ... 1.30 x Us)
◆
D
Voltage
24 42 60 110 220 440
28 48 72 125 250
Thermal overload relay, see K.22
Technical specifications, see K.35
Dimensions, see K.45
H
J
N
Y
Direct current (V) - WIDE VOLTAGE RANGE. For contactors type CL...D / Operating limits: 0.70 ... 1.30 x Us
◆
Maximum number of add-on auxiliary contact
blocks :
CL00D...CL02D : 2NO or 1NC
CL03D...CL45D : 1NO and 1NC
CL05E...CL10E : 4 auxiliary contacts
Different auxiliary contact configurations :
on request
F
WB WD WE WG WI WJ WN
Voltage
12 24 33 48 72 110 220
Note : CL25 not suitable for wide voltage range operations.
Direct current (V) - WIDE VOLTAGE RANGE.
Coil with electronic module for contactors CL...E / Operating limits: 0.70 ... 1.30 x Us
◆
WD WE WF WH WJ WN
Voltage
24 33 48 72 110 220
(1) To complete the catalogue number, replace the symbol ◆ by the code
corresponding to the voltage and frequency of the control circuit.
(2) Can also be used with alternating current.
SERIES CL - Contactors
Four-pole contactors (4NO)
from 25 to 140A (AC1)
– Power circuit (AC): up to 690V
– Control circuit:
Alternating current up to 690V AC
Direct current up to 440V DC
– Terminal numbering in accordance with
EN 50005 and EN 50012
– Fixing by clipping onto 35 mm DIN rail
(EN 50022-35) or by screws.
– Degree of protection CL01... to CL02... : IP20
CL03... to CL09... : IP10
– Screws protected against accidental contact in
accordance with VDE 0106.
– Three coil terminals.
– The types CL...E are also suitable for AC
control.
– Accessories:
Mounting possibilities of front/side
instantaneous auxiliary contact blocks, timed
auxiliary contact blocks, mechanical latch,
transient suppressor block and interface
modules.
CL01A400TN
Control circuit: alternating current
Maximum operating
current
Admissible
power AC1
Electrical Control Power
endurance circuit contacts
Noninductive
load
AC1
AC3
220V 380V 415V 500V Category
230V 400V 440V
AC1
kW kW
Cat. no.(1)
Pack Weight
A
A
kW
kW
25
12
9.5
16.5 18
21.5 1.5 x 106
AC
4
0
CL01A400T ◆
5
0.280
32
18
12
22
27.5 1.5 x 106
AC
4
0
CL02A400T ◆
5
0.280
23
operations
45
25
17
32
39
2 x 10
AC
4
0
CL03A400M ◆
10
0.490
60
32
22.5 39.5 43
52
1.5 x 106
AC
4
0
CL04A400M ◆
10
0.500
90
50
34
59
64
78
1.5 x 106
AC
4
0
CL05A400M ◆
1
1.240
110
65
42
72.5 79
95
1.8 x 106
AC
4
0
CL07A400M ◆
1
1.270
140
95
53
92
1.8 x 106
AC
4
0
CL09A400M ◆
1
1.450
LB1A ◆
LB3A ◆
LB4A ◆
5
5
5
0.063
0.102
0.145
29
100 121
6
Spare coils
CL01 - CL02
CL03 - CL04
CL05 - CL09
Control circuit: direct current
25
12
9.5
16.5 18
21.5 1.5 x 106
DC
4
0
CL01D400T ◆
10
0.490
32
18
12
22
23
27.5 1.5 x 106
DC
4
0
CL02D400T ◆
10
0.490
45
25
17
29
32
39
2 x 106
DC
4
0
CL03D400M ◆
10
0.825
60
32
22.5 39.5 43
52
1.5 x 106
DC
4
0
CL04D400M ◆
10
0.835
90
50
34
78
1.5 x 106
AC/DC
4
0
CL05E400M ◆
1
1.290
95
6
AC/DC
4
0
CL07E400M ◆
1
1.290
1.8 x 106
AC/DC
4
0
CL09E400M ◆
1
1.500
LB1D ◆
LB3D ◆
LB4E ◆
5
5
1
0.205
0.276
0.610
59
64
110
65
42
72.5 79
140
95
53
92
1.8 x 10
100 121
Spare coils
(pure DC coil)
(pure DC coil)
(coil + electronic module)
CL05A400MN
CL00 - CL02
CL03 - CL04
CL05 - CL09
Available coil voltages (1)
Alternating current (V)
◆
C
50Hz
60Hz
D
F
G
H
24 42 48
24
48
J
K
M
110 127
110 120
N
R
S
T
220 240
230
220 277
U
380
400
V
W
X
Y
Z
415 440 500 660
690
240 380 480 440 460
600
Alternating current (V). Dual frequency coil
CL09E400MJ
◆
1
50/60Hz
24 42 110 120 220 230 240 440 48
115
2
3
4
5
6
7
8
9(2)
Direct current (V). For contactors type CL...D / 0.80 ... 1.10 x Us (4)
◆
B
Voltage
12 24 36 42 48 60 72 110 120 220 230 240
125
440
D
E
F
G
H
I
J
K
N
P
R
X
Direct current (V). Coil with electronic module for contactors type CL...E (3) / 0.80 ... 1.10 x Us (4)
◆
D
Voltage
24 42 60 110 220 440
28 48 72 125 250
F
H
J
N
Y
(1) To complete the catalogue number, replace the symbol ◆ by the code
corresponding to the voltage and frequency of the control circuit.
(2) Only for CL00 to CL45.
(3) Can also be used with alternating current.
(4) Wide voltage range 0.70 ... 1.30 x Us, see page K.12
Thermal overload relay, see K.22
Technical specifications, see K.35
Dimensions, see K.45
SERIES CL - Contactors
Four-pole contactors
Control circuit: alternating current
(2NO + 2NC)
Max. operat. current
from 12 to 80A (AC3)
Noninductive
load
– Power circuit (AC): up to 690V
– Control circuit:
Alternating current up to 690V AC
Direct current up to 440V DC
– Terminal numbering in accordance with
EN 50005 and EN 50012
– Fixing by clipping onto 35 mm DIN rail
(EN 50022-35) or by screws.
– Degree of protection CL01... to CL02...: IP20
CL03... to CL09...: IP10
– Screws protected against accidental contact in
accordance with VDE 0106.
– Three coil terminals.
– The types CL...E are also suitable for AC
control.
– Accessories:
Mounting possibilities of front/side
instantaneous auxiliary contact blocks, timed
auxiliary contact blocks, mechanical latch,
transient suppressor block and interface
modules.
CL01AB00TN
AC1
Admissible power AC3
Power contacts Cat. no.(1)
Control
Motors
220V 380V 415V 500V
≤ 440V, 230V 400V 440V
3-phase
50/60 Hz
AC3
A
A
kW
kW
kW
kW
25
12
3
5.5
5.5
7.5
AC
2
2
CL01AB00T ◆
5
32
18
4
7.5
7.5
10
AC
2
2
CL02AB00T ◆
5
0.280
45
25
7.5
12
12
15
AC
2
2
CL03AB00M ◆
10
0.490
60
32
9
16
16
18.5
AC
2
2
CL04AB00M ◆
10
0.500
90
40
11
18.5
22
25
AC
2
2
CL05AB00M ◆
1
1.240
110
65
18.5
30
37
40
AC
2
2
CL07AB00M ◆
1
1.270
110
80
22
37
45
45
AC
2
2
CL08AB00M ◆
1
1.270
LB1A ◆
LB3A ◆
LB4A ◆
5
5
5
0.063
0.102
0.145
Spare coils
CL01 - CL02
CL03 - CL04
CL05 - CL08
0.280
Control circuit: direct current
25
12
3
5.5
5.5
7.5
DC
2
2
CL01DB00T ◆
5
0.490
32
18
4
7.5
7.5
10
DC
2
2
CL02DB00T ◆
5
0.490
45
25
7.5
12
12
15
DC
2
2
CL03DB00M ◆
10
0.825
60
32
9
16
16
18.5
DC
2
2
CL04DB00M ◆
10
0.835
90
40
11
18.5
22
25
DC/AC
2
2
CL05EB00M ◆
1
1.290
110
65
18.5
30
37
40
DC/AC
2
2
CL07EB00M ◆
1
1.320
110
80
22
37
45
45
DC/AC
2
2
CL08EB00M ◆
1
1.320
LB1D ◆
LB3D ◆
LB4E ◆
5
5
1
0.205
0.276
0.610
Spare coils
(pure DC coil)
(pure DC coil)
(coil + electronic module)
CL00 - CL02
CL03 - CL04
CL05 - CL08
CL05EB00MJ
Available coil voltages (1)
Alternative current (V)
◆
C
50Hz
60Hz
D
F
G
H
24 42 48
24
48
J
K
M
110 127
110 120
N
R
S
T
220 240
230
220 277
U
380
400
V
W
◆
1
50/60Hz
24 42 110 120 220 230 240 440 48
115
2
3
4
5
6
7
8
240 380 480 440 460
9(2)
Direct current (V). For contactors type CL...D
◆
B
Voltage
12 24 36 42 48 60 72 110 120 220 230 240 440
125
D
E
F
G
H
I
J
K
N
P
R
X
Direct current (V). Coil with electronic module for contactors type CL...E ( )
◆
D
Voltage
24 42 60 110 220 440
28 48 72 125 250
F
H
J
N
Y
(1) To complete the catalogue number, replace the symbol ◆ by the code
corresponding to the voltage and frequency of the control circuit.
(2) Only for CL00 to CL45.
(3) Can also be used with alternating current.
X
Y
Z
415 440 500 660
690
Alternative current (V). Dual-frequency coil
Technical specifications, see K.35
Dimensions, see K.45
Pack Weight
600
SERIES CL - Accessories
BCLF10
Instantaneous auxiliary contact blocks
– Terminal numbering in accordance with EN 50005 and EN 50012
– Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 : IP20.
– Combinations for contactors and front/side mounted auxiliary contact blocks, see pages K.42 and K.43
For use with
Mounting
Type
Contacts
•3
•4
BCLL11
CL00...CL10
Front
one pole
CL00...CL10
Side
two pole
CL00...CL10
Side (1)
two pole
1
0
0
0
2
1
2
1
Cat. no.
•1 • 7
•2 •8
•6
0
1
0
0
0
1
0
1
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
Pack Weight
•5
BCLF10
BCLF01
BCLF10G
BCLF01G
BCLL20
BCLL11
BRLL20
BRLL11
10
10
10
10
10
10
10
10
0.015
0.015
0.015
0.015
0.048
0.048
0.048
0.048
(1) For combinations of more than 4 front-mounted and 2 side-mounted auxiliary contact blocks
BTLF30C
Pneumatic timer auxiliary contact blocks
For use with
Mounting
Type
Contacts
•7
CL00...CL10
RMLFN
Front
Delayed
ON
CL00...CL10
Front
Delayed
OFF
Sealing cover protection for pneumatic timer
Time
Cat. no.
0.1...30 s.
1.0...60 s.
0.1...30 s.
1.0...60 s.
BTLF30C
BTLF60C
BTLF30D
BTLF60D
BTLFX
Pack Weight
•5
•8
•6
1
1
1
1
1
1
1
1
10
10
10
10
5
0.085
0.085
0.085
0.085
0.001
Mechanical latch blocks
–
–
–
–
Terminal numbering in accordance with EN 50005
Disconnection of the contactor or auxiliary contactor, either using an electrical pulse or manually.
Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4
Frontal selector allows for adaptation in function of the housing of the contactor.
For use with
CL00...CL10
BEL
Cat. no. (2)
RMLF ◆
Pack
Weight
5
0.082
(2) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency
of the control circuit.
◆
50 Hz
60 Hz
DC
D
G
HC
J
N
U
Y
24, 32
42, 48
110, 115, 120, 127 220, 230, 240,
380, 400, 415, 440, 480 500, 660/690
24, 32
48, 60
110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600
24, 32, 36 42, 48 60, 72 110, 120, 125
220, 230, 240, 250 440
Mechanical and mechanical/electrical interlock
Side mounted to the contactor
BEL02
Technical specifications, see K.35
Dimensions, see K.45
For use with
CL00...CL45
CL05...CL10
CL00...CL45
CL05...CL10
Type
Mechanical
Mechanical
Mech./electrical
Mech./electrical
Cat. no.
BELA
BEL
BELA02
BEL02
Pack
Weight
5
5
5
5
0.025
0.025
0.025
0.025
SERIES CL - Accessories
BSLR2R
Transient voltage suppressor block
Directly connected parallel to the coil terminals A1-A2
BETL45C
Control circ.
AC
For use with Type
CL00...CL45... R/C
AC
CL05A...CL10A...
R/C
DC
AC/DC
CL...D...
CL...
Diode
Varistor
Ue
24V...48V
50V...127V
130V...240V
24V...48V
50V...127V
130V...240V
12V...600V
24V...48V
50V...127V
130V...240V
277V...500V
Cat. no.
BSLR2G
BSLR2K
BSLR2R
BSLR3G
BSLR3K
BSLR3R
BSLDZ
BSLV3G
BSLV3K
BSLV3R
BSLV3U
Pack
Weight
10
10
10
10
10
10
10
10
10
10
10
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
Time
0.1...2 s.
1.5...45 s.
0.1...2 s.
1.5...45 s.
Cat. no.
BETL02C
BETL45C
BETL02D
BETL45D
Pack Weight
Ue (DC)
24V
48V
24V
48V
24V
Cat. no.
IMRD
IMRG
IMRFD
IMRFG
IMSSD
IMAMS
Pack
Electronic timer module
Directly connected parallel to the coil terminals A1-A2
Control circ. For use with
24-250V AC/DC CL00 to CL10
Type
Delayed ON
Delayed OFF
IMRD
0.040
0.040
0.040
0.040
Interface module
Directly connected parallel to the coil terminals A1-A2
Control circ.
24-250V AC
24-250V DC
For use with
CL00 to CL10
CL00 to CL45
Type
Relay
Relay +
forced operation
Solid state
Auto / Manual /
Off control
IMRC2R
5
5
5
5
5
5
5
5
5
5
Weight
0.060
0.060
0.050
0.050
0.045
0.045
Transient voltage suppressor block to use with interface modules
To be plugged inside the interface module or inside the electronic timer module.
For use with Type
CL00...CL45... R/C
CL05A...CL10A... R/C
CL...D...
CL...
Diode
Varistor
Con. circ. AC/DC
24V...48V
50V...127V
130V...240V
24V...48V
50V...127V
130V...240V
12V...600V
24V...48V
50V...127V
130V...240V
Cat. no.
IMRC2G
IMRC2K
IMRC2R
IMRC3G
IMRC3K
IMRC3R
IMD1Z
IMV3G
IMV3K
IMV3R
Pack
Weight
10
10
10
10
10
10
10
10
10
10
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
Cat. no.
PTP04
PTP45
PTP08
PTP10
Pack
Weight
Pole terminal protector IP xxB
For use with
CL03...CL04...
CL45...
CL05...CL08...
CL09...CL10...
Mounting
Single pole IPxxB
Single pole IPxxB
Single pole IPxxB
Single pole IPxxB
8
6
8
8
Identification
Technical specifications, see K.35
Dimensions, see K.45
Sheets of labels (10 sheets of 260 labels each)
Labeling plate base (50 pieces in one pack)
EAT260
SPR
1
1
0.050
0.001
SERIES CL - Accessories
Alternating current
Coils
CL...A
Cat. no. (1)
LB1A ◆
LB3A ◆
LB4A ◆
For use with
CL00...CL25
CL03...CL45
CL05...CL10
LB4AN
Pack
5
5
5
Weight
0.063
0.102
0.145
Alternating current (V)
◆
C
D
50Hz
60Hz
F
G
H
24 42 48
24
48
J
K
M
110 127
110 120
N
R
220 240
230
220 277
S
T
U
V
380
400
W
X
Y
Z
415 440 500 660
690
240 380 480 440 460
600
Alternating current (V) Dual-frequency coil
◆
1
50/60Hz
24 42 110-115 120 220 230 240 440 48
2
3
4
5
6
7
8
9(2)
(1) To complete the catalogue number, replace the symbol ◆ by the corresponding code.
(2) Only for CL00 to CL45
Direct current
(2)
CL...D
◆
Voltage
For use with
CL00...CL25
CL03...CL45
B
12
D
24
F
42
G
48
H
60
I
72
Cat. no. (1)
LB1D ◆
LB3D ◆
Pack
5
5
Weight
0.205
0.276
J
K
N
P
R
X
110 120 220 230 240 440
125
(1) To complete the catalogue number, replace the symbol ◆ by the corresponding code.
Direct current (V) with electronic module (also for use with alternating current) (2)
CL...E
◆
Voltage
For use with
CL05...CL10
D
24
28
F
42
48
Cat. no. (1)
LB4E ◆
Pack
Weight
1
0.610
H
J
N
Y
60 110 220 440
72 125 250
(1) To complete the catalogue number, replace the symbol ◆ by the corresponding code.
(2) Operating limits 0.80 up to 1.10 x Us. For operating limits 0.70 up to1.30 x Us : see page K.12
Contact kits
For use with
CL00...
CL01...3..., CL01...4...
CL01...B
CL02...3, CL02...4...
CL02...B...
CL25...3...
CL03...,CL03...4...
CL03...B...
CL04...3..., CL04...4...
CL04...B
CL45...3...
CL05...4...
CL05...B...
CL06...
CL07...3..., CL07...4...
CL07...B...
CL08...3...
CL08...B...
CL09...
CL10...
Number of sets (1)
3
3
4
3
4
3
3
4
3
4
3
4
4
3
3
4
3
4
3
3
Type
NO
NO
2NO-2NC
NO
2NO-2NC
NO
NO
2NO-2NC
NO
2NO-2NC
NO
NO
2NO-2NC
NO
NO
2NO-2NC
NO
2NO-2NC
NO
NO
Cat. no.
V31200B
V31201B
VB1201B
V31202B
VB1202B
V31225B
V31203B
VB1203B
V31204B
VB1204B
V31245B
V31205B
VB1205B
V31206B
V31207B
VB1207B
V31208B
VB1208B
V31209B
V31210B
Pack Weight
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(1) One set consists of two fixed contacts, one moving contact and accessory parts.
0.025
0.025
0.035
0.025
0.035
0.035
0.035
0.050
0.035
0.050
0.035
0.080
0.100
0.080
0.090
0.110
0.090
0.110
0.120
0.130
SERIES CL - Technical data
Climatic resistance
IEC 68-2
General
Conformity to standards
IEC 947-1
CENELEC HD 419
CEI EN 60947-4-1
UL 508
EN 50005
IEC 947-4-1
NF C 63-110
ASE 1025
CSA 22.2/14
UNE 20109
BS 5424 & 775
NEMA ICS 1
VDE 0660/102
Approvals
UL
CSA
IMQ (up to Ith: 32 A)
SETI
RINA
Lloyds’ Register of Shipping
Bureau Veritas
40/125/56 Cyclical tests (humide test)
First half-cycle
– 40°C – Low temperature
+ 25°C
72 h – Relative humidity
93 %
– Time
12 h
+ 125°C Second half-cycle
≤ 50 % – Low temperature
+ 55 %
96 h – Relative humidity
95 %
– Time
12 h
+ 40°C Number of consecutive
95 % cycles
6
56 days
Mounting positions
Ambient conditions
Storage temperature
Operation temperature
Operating altitude up to 3,000 m
Operating altitude from 3,000 to 4,000 m
Operating altitude from 4,000 to 5,000 m
Continuous tests
Cold
– Temperature
– Time
Dry heat
– Temperature
– Relative humidity
– Time
Humid heat
– Temperature
– Relative humidity
– Time
– 55°C to + 80°C
– 40°C to + 60°C
Nominal values
90 % Ie 80 % Ue
80 % Ie 75 % Ue
With the same pick-up and drop-out voltage.
With the same rated power.
Terminal capacity and tightening torque
CL00 ... CL02
Solid, stranded and finely
2 x 0.5 ... 2.5
stranded without end sleeve (mm2) or 2 x 2.5 ... 6
Finely stranded with or
2 x 1 ... 2.5
without end sleeve
(mm2) or 2 x 2.5 ... 6
AWG wires
2 x 20 ... 12
Tightening torque
1.6 Nm
15 Lb x in
Solid, stranded and finely
stranded without end sleeve (mm2) –
Finely stranded with
end sleeve
(mm2) –
Finely stranded without
end sleeve
(mm2) –
AWG wires
–
Tightening torque
–
–
Solid
(mm2) –
Stranded
(mm2) –
Finely stranded without
end sleeve
(mm2) –
Finely stranded with
end sleeve
(mm2) –
AWG wires
–
Tightening torque
–
–
Solid, stranded and finely
–
stranded without end sleeve (mm2) –
Finely stranded without
–
end sleeve
(mm2) –
Finely stranded with
–
end sleeve
(mm2) –
AWG wires
–
–
Tightening torque
–
–
CL25
2 x 0.5 .. 2.5
or 2 x 2.5 ... 10
2 x 1 ... 2.5
or 2 x 2.5 ... 10
2 x 20 ... 8
2.2 Nm
20 Lb x in
CL03 ...CL04
–
–
–
–
–
–
–
CL45
–
–
–
–
–
–
–
CL05 ... CL08
–
–
–
–
–
–
–
CL09 ... CL10
–
–
–
–
–
–
–
–
0.75 ... 16
0.75 ... 16
1 ... 35
1.5 ... 50
–
0.75 ... 16
0.75 ... 16
1 ... 35
1.5 ... 50
–
–
–
–
–
–
1 ... 16
18 ... 6
1.4 Nm
12 Lb x in
0.75 ... 16
0.75 ... 16
1 ... 16
18 ... 6
1.8 Nm
16 Lb x in
0.75 ... 16
0.75 ... 16
1 ... 35
16 ... 2
4 Nm
35 Lb x in
1 ... 16
1 ... 25
1.5 ... 50
16 ... 2
5.6 Nm
50 Lb x in
4 ... 35
4 ... 35
–
0.75 ... 16
0.75 ... 16
1 ... 25
4 ... 35
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1 ... 16
18 ... 6
1.4 Nm
12 Lb x in
Max. 16
1 ... 16
18 ... 6
1.8 Nm
16 Lb x in
Max. 16
4 ... 35
10 ... 1
5.6 Nm
50 Lb x in
Max. 50 ... 35
Max. 16
Max. 16
Max. 16
Max. 16
Max. 6
Max. 6
1.4 Nm
12 Lb x in
1.8 Nm
16 Lb x in
1 ... 25
16 ... 4
4 Nm
35 Lb x in
Max. 50 ... 4
Max. 25 ... 16
Max. 35 ... 2.5
Max. 25 ... 16
Max. 35 ... 16
Max. 25 ... 25
Max. 2 ... 12
Max 4 ... 4
4 Nm
35 Lb x in
Max. 35
Max. 35
Max. 1
5.6 Nm
50 Lb x in
SERIES CL - Technical data
Power circuit
Three-pole version
Rated thermal current Ith at θ ≤ 55°C
Rated operational current Ie
Rated operational voltage Ue
(A)
(A)
(V)
CL00
25
9
690
CL01
25
12
690
CL02
32
18
690
CL25
45
25
690
CL03
45
25
690
CL04
60
32
690
CL45
60
40
690
CL06
90
50
690
CL07
110
65
690
CL08
110
80
690
CL09
140
95
690
CL10
140
105
690
Four-pole version (4 NO and 2 NO + 2 NC)
Rated thermal current Ith at θ ≤ 55°C
Rated operational voltage Ue
CL01 CL02
25
32
690
690
(A)
(V)
CL03 CL04
45
60
690
690
CL07 CL08(1) CL09(2)
110 110
140
690 690
690
CL05
90
690
(1) 2 NO + 2 NC only
(2) 4 NO only
Three-pole and four-pole version
Rated insulation voltage Ui
Maximum continuous current AC1
Frequency limits
Making capacity (RMS) (acc. IEC 947)
Breaking capacity (RMS) (acc. IEC 947)
Ue ≤ 400V
Ue = 500V
Ue = 690V
Short-time current
1 sec.
5 sec.
10 sec.
30 sec.
1 min.
3 min.
Recovery time
Protection against short-circuits with fuses
Coordination type "2"
aM
gL-gG
Without welding
aM
gL-gG
Impedance per pole
Power dissipation per pole
AC1
AC3
Insulation resistance
Between adjacent poles
Between poles and earth
Between input and output
CL00
1000
25
25..400
450
CL01
1000
25
25..400
450
CL02 CL25 CL03
1000 1000 1000
32
45
45
25..400 25..400 25..400
450 450 550
CL04
1000
60
25..400
550
CL45 CL05
1000 1000
60
90
25..400 25..400
550 1000
CL06 CL07
1000 1000
90
110
25..400 25..400
1000 1000
CL08
1000
110
25..400
1000
CL09
1000
140
25..400
1280
CL10
1000
140
25..400
1280
(A)
(A)
(A)
250
250
130
250
250
130
250
250
130
350
320
170
450
450
205
450
450
205
450
450
205
920
920
780
920
920
780
920
920
780
920
920
780
1050
1050
950
1050
1050
950
(A)
(A)
(A)
(A)
(A)
(A)
(min.)
455
205
144
85
60
35
10
455
205
144
85
60
35
10
570
254
180
104
74
46
10
630
280
200
115
80
50
10
1010
450
320
185
130
90
10
1010
450
320
185
130
90
10
1265
450
400
230
165
100
10
1580
565
500
290
205
120
10
1580
710
500
290
205
120
10
2530
1130
800
460
325
185
10
2530
1130
800
460
325
185
10
3300
1485
1050
600
430
250
10
3300
1485
1050
600
430
250
10
10
25
12
35
20
35
25
50
25
63
35
63
40
63
40
100
50
100
80
160
80
160
125
200
160
200
(A)
(A)
(mΩ)
8
10
2.35
8
10
2.35
16
25
2.41
20
35
1.65
20
35
1.28
20
35
1.28
25
50
0.95
35
80
0.85
40
80
0.85
50
100
0.86
50
100
0.86
80
160
0.76
80
160
0.76
(W)
(W)
1.47
0.19
1.47
0.34
2.46
0.78
3.34
1.03
2.59
0.80
4.6
1.31
3.42
1.52
6.89
1.36
6.89
2.12
10.4
3.63
10.4
5.5
14.89 14.89
6.86 8.37
(MΩ)
(MΩ)
(MΩ)
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
>10
(V)
(A)
(Hz)
(A)
(A)
(A)
>10
>10
>10
SERIES CL - Technical data
Control circuit
Three-pole and four-pole contactors
Alternating current
Rated insulation voltage Ui
(V)
Standard voltages Us 50 Hz
(V)
Standard voltages Us 60 Hz
(V)
Voltage operating limits monofrequency coils
Operating
xUs
Pick-up
xUs
Seal
xUs
Voltage operating limits coils 50/60 Hz
Operating 50 Hz
xUs
Operating 60 Hz
xUs
Pick-up 50 Hz
xUs
Pick-up 60 Hz
xUs
Seal 50 Hz
xUs
Seal 60 Hz
xUs
Consumption monofrequency coils
Seal
(VA)
Pick-up
(VA)
Consumption bifrequency coils
Seal (50 Hz/60 Hz)
(VA)
Pick-up (50 Hz/60 Hz)
(VA)
Thermal power dissipation (50 Hz/60 Hz))
(W)
Power factor
Magnetic circuit closed
(cos ϕ)
Magnetic circuit open
(cos ϕ)
Opening and closing times
Values between + 10 % Us and – 20 % Us
Making time on excitation (NO contact) (ms)
Breaking time on de-excitation (NO contact) (ms)
Values at Us
Making time on excitation (NO contact) (ms)
Breaking time on de-excitation (NO contact) (ms)
Mechanical endurance
Monofrequency coils
106 ops.
Bifrequency coils (at 50 Hz)
106 ops.
Maximum rate
Monofrequency coils no load
ops./h
AC1 at rated power
ops./h
AC2 at rated power
ops./h
AC3 at rated power
ops./h
AC4 at rated power
ops./h
Bifrequency coils
no load
ops./h
Direct current
Rated insulation voltage Ui
(V)
Standard voltages Us
(V)
Operating limits
Operating
xUs
Pick-up
xUs
Drop-out
xUs
Consumption
Magnetic circuit closed
(W)
Magnetic circuit open
(W)
Opening and closing times
Values between + 10 % Us and – 20 % Us
Making time on excitation (NO contact) (ms)
Breaking time on de-excitation (NO contact) (ms)
Values at Us
Making time on excitation (NO contact) (ms)
Breaking time on de-excitation (NO contact) (ms)
Mechanical endurance
106 ops.
Maximum rate
No load
ops./h
AC1 and AC3 at rated power
ops./h
AC4 at rated power
ops./h
CL00...CL25
1000
24...690
24...600
CL03...CL45
1000
24...690
24...600
CL05...CL08
1000
24...690
24...600
CL09...CL10
1000
24...690
24...600
0.8...1.1
0.6...0.8
0.35...0.55
0.8...1.1
0.65...0.8
0.4...0.6
0.8...1.1
0.65...0.8
0.4...0.6
0.8...1.1
0.65...0.8
0.4...0.6
0.8...1.1
0.85...1.1
0.5...0.8
0.65...0.85
0.3...0.55
0.35...0.35
0.8...1.1
0.85...1.1
0.6...0.8
0.7...0.85
0.35...0.60
0.4...0.6
0.8...1.1
0.85...1.1
0.6...0.8
0.7...0.85
0.35...0.60
0.4...0.6
0.8...1.1
0.85...1.1
0.6...0.8
0.7...0.85
0.35...0.60
0.4...0.6
6
45
9
88
15.5
191
15.5
191
7/5
54 / 35
2 / 1.7
11.4 / 11
120 / 105 (1)
2.8 / 3.3
20 / 15
245 / 215
4.5 / 3.9
20 / 15
245 / 215
4.5 / 3.9
0.39
0.82
0.31
0.76
0.35
0.64
0.35
0.64
6...20
6...13
7...25
5...25
9...35
9...15
9...35
9...15
8...20
6...13
10...19
5...25
15...30
9...15
15...30
9...15
15
10
15
10
15
8
15
8
9000
1200
1000
1200
360
3600
9000
1200
1000
1200
360
3600
9000
1200
1000
1200
200
3600
5000
1200
750
600
200
3600
CL00D...CL25D CL03D...CL45D CL05E...CL08E CL09E...CL10E
1000
1000
1000
1000
12...440
12...440
24...440
24...440
0.8...1.1
0.45...0.65
0.15...0.3
0.8...1.1
0.45...0.65
0.15...0.3
0.8...1.1
0.70...0.80
0.4...0.6
0.8...1.1
0.70...0.80
0.4...0.6
5.5
5.5
8
8
10
170
10
170
35...65
6...15
35...70
40...65
60...80
40...50
60...80
40...50
35...45
7...12
15
40...55
30...65
15
50...60
55...60
12
50...60
55...60
12
3600
1200
360
3600
1200
360
2500
1200
200
2500
600
200
(1)
for CL45 : 125 / 110
SERIES CL - Dimensional drawings
Three-pole and four-pole AC contactors
Three-pole and four-pole DC contactors
CL00A3 . . T
CL01A3 . . T
CL01A4 . . T
CL02A3 . . T
CL02A4 . . T
CL25A300T
CL25A310T
CL25A301T
A
85
85
85
85
85
87
87
87
CL03A3 . . M
CL03A4 . . M
CL04A3 . . M
CL04A4 . . M
CL45A300M
CL45A311M
B
–
–
–
–
–
–
29
29
CL00D3 . . T
CL01D3 . . T
CL01D4 . . T
CL02D3 . . T
CL02D4 . . T
CL25D300T
A
–
–
–
–
–
29
Three-pole AC contactors
A
115
115
115
115
–
117
CL03D3 . . M
CL03D4 . . M
CL04D3 . . M
CL04D4 . . M
CL45D300M
Three-pole DC contactors
CL06A3 . . M
CL07A3 . . M
CL08A3 . . M
CL06E3 . . M
CL07E3 . . M
CL08E3 . . M
CL09A3 . . M
CL10A3 . . M
CL09E3 . . M
CL10E3 . . M
Four-pole AC contactors
Four-pole DC contactors
CL05A4 . . M
CL07A4 . . M
CL05AB . . M
CL07AB . . M
CL08AB . . M
CL05E3 . . M
CL07E3 . . M
CL05EB . . M
CL07EB . . M
CL08EB . . M
CL09A4 . . M
CL09E4 . . M
SERIES CL - Dimensional drawings
Front mounting auxiliary
contact blocks
Electronic timer block
CL00...CL25
Voltage suppressor block
CL00...CL25
BCLF
Lateral mounting auxiliary
contact blocks
CL03...CL45
CL03...CL45
CL05...CL10
BRLL
BCLL
CL05...CL10
Pneumatic timer block
BSLR
BSLDZ
BSLV
BTL02
BTL45
BTLF
Mechanical latch block
RMLF
Interface modules
CL00...CL25
CL03...CL45
Mechanical /
mechanical-electrical interlock
BELA
BEL
BELA02
BEL02
CL05...CL10
IMR◆
IMRF◆
IMSSD
IMAMS