SERIES CL - CK - Contactors Contactors Series CL � � � � � A=AC D=DC E=DC/AC with electronic module � � Type identification � � ➀ Contactor (see K.11) ➁ Auxiliary contacts side-mounted (see K.15) ➂ Mechanical interlock (see K.15) ➃ Auxiliary contacts front-mounted (see K.15) ➄ Electronic timer block (see K.16) ➅ Transient voltage suppressor block (see ie K.16) ➆ Mechanical latch block (see K.15) ➇ Pneumatic timer block (see K.15) ➈ Thermal overload relay (see K.22) � C Housing 00 05 01 06 02 07 25 08 03 09 04 10 45 Auxiliary contacts NO Auxiliary contacts NC Control voltage L 3 = 3-pole 4 = 4-pole NO B = 4-pole 2NO + 2NC T = screw terminal M = double clamp terminal Contactors Series CK Type identification C A=AC E=DC/AC with electronic module Housing 07 10 75 11 08 12 85 13 09 95 Auxiliary contacts NO Auxiliary contacts NC Control voltage K Version (B, C) 3 = 3-pole 4 = 4-pole (4NO) Thermal overload relay RT Type identification R Setting range (A...W) T Housing 2 = class 10A (RT1) class 10 (RT2, RT3, RT4, RT5, RT6) = class 20 (RT1. RT2. RT3) L = class 30 – (RT4, RT5, RT6) K 5 SERIES CL - Contactors Three-pole contactors from 9 to 105A (AC3) – Power circuit (AC): up to 690V – Control circuit: Alternating current up to 690V AC – Terminal numbering in accordance with EN 50005 and EN 50012 – Fixing by clipping onto 35 mm DIN rail EN 50022-35 or by screws – Degree of protection CL00... to CL02... : IP20 CL25... to CL10... : IP10 – Screws protected against accidental contact in accordance with VDE 0106. – Three coil terminals. – Accessories: Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules – Maximum number of auxiliary contacts: four for CL00...CL25 six for CL03...CL45 eight for CL06...CL10 CL00A310TN CL45A300MN Control circuit: alternating current Max. operat. current Noninductive load Elec. endur. Aux. contacts Cat. no.(1) Admissible power AC3 Motors 220V 380V 415V 500V ≤ 440V 230V 400V 440V 3-phase 50/60 Hz AC3 Category AC3 A A kW kW kW kW # ops. 25 9 2.2 4 4 5.5 25 12 3 5.5 5.5 32 18 4 7.5 45 25 7.5 45 25 60 •3 •1 •4 •2 2 x 106 0 1 0 0 0 1 CL00A300T ◆ CL00A310T ◆ CL00A301T ◆ 10 10 10 0.280 0.295 0.295 7.5 2 x 106 0 1 0 0 0 1 CL01A300T ◆ CL01A310T ◆ CL01A301T ◆ 10 10 10 0.280 0.295 0.295 7.5 10 1.7 x 106 0 1 0 0 0 1 CL02A300T ◆ CL02A310T ◆ CL02A301T ◆ 10 10 10 0.280 0.295 0.295 11 11 15 2 x 106 0 1 0 0 0 1 CL25A300T ◆ 10 CL25A310T ◆(2) 10 CL25A301T ◆(2) 10 0.270 0.285 0.285 7.5 12 12 15 2 x 106 1 0 0 1 CL03A310M ◆ CL03A301M ◆ 10 10 0.490 0.490 32 9 16 16 18.5 2 x 106 0 1 0 0 0 1 CL04A300M ◆ CL04A310M ◆ CL04A301M ◆ 10 10 10 0.500 0.520 0.520 60 40 11 18.5 22 25 2 x 106 0 1 0 1 CL45A300M ◆ 10 CL45A311M ◆(3) 10 0.490 0.540 90 50 15 22 25 30 1.8 x 106 0 1 0 1 CL06A300M ◆ 1 CL06A311M ◆(3) 1 1.075 1.105 110 65 18.5 30 37 40 1.7 x 106 0 1 0 1 CL07A300M ◆ 1 CL07A311M ◆(3) 1 1.090 1.120 110 80 22 37 45 45 1.5 x 106 0 1 0 1 CL08A300M ◆ 1 CL08A311M ◆(3) 1 1.110 1.130 140 95 25 45 50 55 1.7 x 106 0 1 0 1 CL09A300M ◆ 1 CL09A311M ◆(3) 1 1.000 1.450 140 105 30 55 55 65 1.5 x 106 0 1 0 1 CL10A300M ◆ 1 CL10A311M ◆(3) 1 1.440 1.470 LB1A◆ LB3A◆ LB4A ◆ 0.063 0.102 0.145 AC1 Spare coils Alternating current CL00 - CL25 CL03 - CL45 CL06 - CL10 Available coil voltages (1) Alternating current (V) CL07A300MN ◆ C 50Hz 60Hz D F G J K M 24 42 48 110 127 24 48 120 N R U 220 240 380 230 400 220 277 V W X 480 440 460 ◆ 1 50/60Hz 24 42 110 120 220 230 240 440 48 115 2 3 4 5 6 7 8 Y Z 415 440 500 660 690 Alternating current (V) Dual-frequency coil 9(4) (1) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. (2) Equipped with one block BCLF (see K.16) (3) Equipped with two blocks BCLF (see K.16) (4) Only for CL00 to CL45 Thermal overload relay, see K.22 Technical specifications, see K.35 Dimensions, see K.45 Pack Weight 600 5 5 5 SERIES CL - Contactors Three-pole contactors from 9 to 105A (AC3) – Control circuit : Direct current up to 440V – Terminal numbering in accordance with EN 50005 and EN 50012 – Fixing by clipping onto 35 mm DIN rail EN 50022-35 or by screws – Degree of protection CL00... to CL02... : IP20 CL25... to CL10... : IP10 – Screws protected against accidental contact in accordance with VDE 0106. – Three coil terminals. – The types CL...E are also suitable for AC control. – Accessories: Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules – Maximum number of auxiliary contacts: four for CL00...CL25 six for CL03...CL45 eight for CL06...CL10 CL00D310TD Control circuit: direct current Max. operat. current Noninductive load Elec. endur. Aux. contacts Cat. no.(1) Admissible power AC3 Motors 220V 380V 415V 500V ≤ 440V 230V 400V 440V 3-phase 50/60 Hz AC3 Category AC3 A A kW kW kW kW operations 25 9 2.2 4 4 5.5 25 12 3 5.5 5.5 32 18 4 7.5 45 25 7.5 45 25 60 Pack Weight •3 •1 •4 •2 2 x 106 1 0 0 1 CL00D310T ◆ CL00D301T ◆ 5 5 0.490 0.490 7.5 2 x 106 1 0 0 1 CL01D310T ◆ CL01D301T ◆ 5 5 0.490 0.490 7.5 10 1.7 x 106 1 0 0 1 CL02D310T ◆ CL02D301T ◆ 5 5 0.490 0.490 11 11 15 2 x 106 0 0 CL25D300T ◆ 5 0.480 7.5 12 12 15 2 x 106 1 0 0 1 CL03D310M ◆ CL03D301M ◆ 10 10 0.480 0.480 32 9 16 16 18.5 2 x 106 1 0 0 1 CL04D310M ◆ CL04D301M ◆ 10 10 0.835 0.835 60 40 11 18.5 22 25 2 x 106 0 0 CL45D300M ◆ 10 0.825 90 50 15 22 25 30 1.8 x 106 0 0 CL06E300M ◆ 1 1.095 110 65 18.5 30 37 40 1.7 x 106 0 0 CL07E300M ◆ 1 1.110 110 80 22 37 45 45 1.5 x 106 0 0 CL08E300M ◆ 1 1.120 140 95 25 45 50 55 1.7 x 106 0 0 CL09E300M ◆ 1 1.440 140 105 30 55 55 65 1.5 x 106 0 0 CL10E300M ◆ 1 1.460 LB1D ◆ LB3D ◆ LB4E ◆ 5 5 1 0.205 0.276 0.610 AC1 Spare coils (pure DC coil) (pure DC coil) (coil + electronic module) CL00 - CL25 CL03 - CL45 CL06 - CL10 Available coil voltages (1) Direct current (V). For contactors type CL...D / Operating limits: 0.80 ... 1.10 x Us ◆ B Voltage 12 24 36 42 48 60 72 110 120 220 230 240 125 440 D E F G H I J K N P R X Direct current (V). Coil with electronic module for contactors CL...E (˝) / Operating limits: 0.80 ... 1.10 x Us For contactors with WIDE VOLTAGE RANGE only (0.70 ... 1.30 x Us) ◆ D Voltage 24 42 60 110 220 440 28 48 72 125 250 Thermal overload relay, see K.22 Technical specifications, see K.35 Dimensions, see K.45 H J N Y Direct current (V) - WIDE VOLTAGE RANGE. For contactors type CL...D / Operating limits: 0.70 ... 1.30 x Us ◆ Maximum number of add-on auxiliary contact blocks : CL00D...CL02D : 2NO or 1NC CL03D...CL45D : 1NO and 1NC CL05E...CL10E : 4 auxiliary contacts Different auxiliary contact configurations : on request F WB WD WE WG WI WJ WN Voltage 12 24 33 48 72 110 220 Note : CL25 not suitable for wide voltage range operations. Direct current (V) - WIDE VOLTAGE RANGE. Coil with electronic module for contactors CL...E / Operating limits: 0.70 ... 1.30 x Us ◆ WD WE WF WH WJ WN Voltage 24 33 48 72 110 220 (1) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. (2) Can also be used with alternating current. SERIES CL - Contactors Four-pole contactors (4NO) from 25 to 140A (AC1) – Power circuit (AC): up to 690V – Control circuit: Alternating current up to 690V AC Direct current up to 440V DC – Terminal numbering in accordance with EN 50005 and EN 50012 – Fixing by clipping onto 35 mm DIN rail (EN 50022-35) or by screws. – Degree of protection CL01... to CL02... : IP20 CL03... to CL09... : IP10 – Screws protected against accidental contact in accordance with VDE 0106. – Three coil terminals. – The types CL...E are also suitable for AC control. – Accessories: Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules. CL01A400TN Control circuit: alternating current Maximum operating current Admissible power AC1 Electrical Control Power endurance circuit contacts Noninductive load AC1 AC3 220V 380V 415V 500V Category 230V 400V 440V AC1 kW kW Cat. no.(1) Pack Weight A A kW kW 25 12 9.5 16.5 18 21.5 1.5 x 106 AC 4 0 CL01A400T ◆ 5 0.280 32 18 12 22 27.5 1.5 x 106 AC 4 0 CL02A400T ◆ 5 0.280 23 operations 45 25 17 32 39 2 x 10 AC 4 0 CL03A400M ◆ 10 0.490 60 32 22.5 39.5 43 52 1.5 x 106 AC 4 0 CL04A400M ◆ 10 0.500 90 50 34 59 64 78 1.5 x 106 AC 4 0 CL05A400M ◆ 1 1.240 110 65 42 72.5 79 95 1.8 x 106 AC 4 0 CL07A400M ◆ 1 1.270 140 95 53 92 1.8 x 106 AC 4 0 CL09A400M ◆ 1 1.450 LB1A ◆ LB3A ◆ LB4A ◆ 5 5 5 0.063 0.102 0.145 29 100 121 6 Spare coils CL01 - CL02 CL03 - CL04 CL05 - CL09 Control circuit: direct current 25 12 9.5 16.5 18 21.5 1.5 x 106 DC 4 0 CL01D400T ◆ 10 0.490 32 18 12 22 23 27.5 1.5 x 106 DC 4 0 CL02D400T ◆ 10 0.490 45 25 17 29 32 39 2 x 106 DC 4 0 CL03D400M ◆ 10 0.825 60 32 22.5 39.5 43 52 1.5 x 106 DC 4 0 CL04D400M ◆ 10 0.835 90 50 34 78 1.5 x 106 AC/DC 4 0 CL05E400M ◆ 1 1.290 95 6 AC/DC 4 0 CL07E400M ◆ 1 1.290 1.8 x 106 AC/DC 4 0 CL09E400M ◆ 1 1.500 LB1D ◆ LB3D ◆ LB4E ◆ 5 5 1 0.205 0.276 0.610 59 64 110 65 42 72.5 79 140 95 53 92 1.8 x 10 100 121 Spare coils (pure DC coil) (pure DC coil) (coil + electronic module) CL05A400MN CL00 - CL02 CL03 - CL04 CL05 - CL09 Available coil voltages (1) Alternating current (V) ◆ C 50Hz 60Hz D F G H 24 42 48 24 48 J K M 110 127 110 120 N R S T 220 240 230 220 277 U 380 400 V W X Y Z 415 440 500 660 690 240 380 480 440 460 600 Alternating current (V). Dual frequency coil CL09E400MJ ◆ 1 50/60Hz 24 42 110 120 220 230 240 440 48 115 2 3 4 5 6 7 8 9(2) Direct current (V). For contactors type CL...D / 0.80 ... 1.10 x Us (4) ◆ B Voltage 12 24 36 42 48 60 72 110 120 220 230 240 125 440 D E F G H I J K N P R X Direct current (V). Coil with electronic module for contactors type CL...E (3) / 0.80 ... 1.10 x Us (4) ◆ D Voltage 24 42 60 110 220 440 28 48 72 125 250 F H J N Y (1) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. (2) Only for CL00 to CL45. (3) Can also be used with alternating current. (4) Wide voltage range 0.70 ... 1.30 x Us, see page K.12 Thermal overload relay, see K.22 Technical specifications, see K.35 Dimensions, see K.45 SERIES CL - Contactors Four-pole contactors Control circuit: alternating current (2NO + 2NC) Max. operat. current from 12 to 80A (AC3) Noninductive load – Power circuit (AC): up to 690V – Control circuit: Alternating current up to 690V AC Direct current up to 440V DC – Terminal numbering in accordance with EN 50005 and EN 50012 – Fixing by clipping onto 35 mm DIN rail (EN 50022-35) or by screws. – Degree of protection CL01... to CL02...: IP20 CL03... to CL09...: IP10 – Screws protected against accidental contact in accordance with VDE 0106. – Three coil terminals. – The types CL...E are also suitable for AC control. – Accessories: Mounting possibilities of front/side instantaneous auxiliary contact blocks, timed auxiliary contact blocks, mechanical latch, transient suppressor block and interface modules. CL01AB00TN AC1 Admissible power AC3 Power contacts Cat. no.(1) Control Motors 220V 380V 415V 500V ≤ 440V, 230V 400V 440V 3-phase 50/60 Hz AC3 A A kW kW kW kW 25 12 3 5.5 5.5 7.5 AC 2 2 CL01AB00T ◆ 5 32 18 4 7.5 7.5 10 AC 2 2 CL02AB00T ◆ 5 0.280 45 25 7.5 12 12 15 AC 2 2 CL03AB00M ◆ 10 0.490 60 32 9 16 16 18.5 AC 2 2 CL04AB00M ◆ 10 0.500 90 40 11 18.5 22 25 AC 2 2 CL05AB00M ◆ 1 1.240 110 65 18.5 30 37 40 AC 2 2 CL07AB00M ◆ 1 1.270 110 80 22 37 45 45 AC 2 2 CL08AB00M ◆ 1 1.270 LB1A ◆ LB3A ◆ LB4A ◆ 5 5 5 0.063 0.102 0.145 Spare coils CL01 - CL02 CL03 - CL04 CL05 - CL08 0.280 Control circuit: direct current 25 12 3 5.5 5.5 7.5 DC 2 2 CL01DB00T ◆ 5 0.490 32 18 4 7.5 7.5 10 DC 2 2 CL02DB00T ◆ 5 0.490 45 25 7.5 12 12 15 DC 2 2 CL03DB00M ◆ 10 0.825 60 32 9 16 16 18.5 DC 2 2 CL04DB00M ◆ 10 0.835 90 40 11 18.5 22 25 DC/AC 2 2 CL05EB00M ◆ 1 1.290 110 65 18.5 30 37 40 DC/AC 2 2 CL07EB00M ◆ 1 1.320 110 80 22 37 45 45 DC/AC 2 2 CL08EB00M ◆ 1 1.320 LB1D ◆ LB3D ◆ LB4E ◆ 5 5 1 0.205 0.276 0.610 Spare coils (pure DC coil) (pure DC coil) (coil + electronic module) CL00 - CL02 CL03 - CL04 CL05 - CL08 CL05EB00MJ Available coil voltages (1) Alternative current (V) ◆ C 50Hz 60Hz D F G H 24 42 48 24 48 J K M 110 127 110 120 N R S T 220 240 230 220 277 U 380 400 V W ◆ 1 50/60Hz 24 42 110 120 220 230 240 440 48 115 2 3 4 5 6 7 8 240 380 480 440 460 9(2) Direct current (V). For contactors type CL...D ◆ B Voltage 12 24 36 42 48 60 72 110 120 220 230 240 440 125 D E F G H I J K N P R X Direct current (V). Coil with electronic module for contactors type CL...E ( ) ◆ D Voltage 24 42 60 110 220 440 28 48 72 125 250 F H J N Y (1) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. (2) Only for CL00 to CL45. (3) Can also be used with alternating current. X Y Z 415 440 500 660 690 Alternative current (V). Dual-frequency coil Technical specifications, see K.35 Dimensions, see K.45 Pack Weight 600 SERIES CL - Accessories BCLF10 Instantaneous auxiliary contact blocks – Terminal numbering in accordance with EN 50005 and EN 50012 – Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 : IP20. – Combinations for contactors and front/side mounted auxiliary contact blocks, see pages K.42 and K.43 For use with Mounting Type Contacts •3 •4 BCLL11 CL00...CL10 Front one pole CL00...CL10 Side two pole CL00...CL10 Side (1) two pole 1 0 0 0 2 1 2 1 Cat. no. •1 • 7 •2 •8 •6 0 1 0 0 0 1 0 1 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 Pack Weight •5 BCLF10 BCLF01 BCLF10G BCLF01G BCLL20 BCLL11 BRLL20 BRLL11 10 10 10 10 10 10 10 10 0.015 0.015 0.015 0.015 0.048 0.048 0.048 0.048 (1) For combinations of more than 4 front-mounted and 2 side-mounted auxiliary contact blocks BTLF30C Pneumatic timer auxiliary contact blocks For use with Mounting Type Contacts •7 CL00...CL10 RMLFN Front Delayed ON CL00...CL10 Front Delayed OFF Sealing cover protection for pneumatic timer Time Cat. no. 0.1...30 s. 1.0...60 s. 0.1...30 s. 1.0...60 s. BTLF30C BTLF60C BTLF30D BTLF60D BTLFX Pack Weight •5 •8 •6 1 1 1 1 1 1 1 1 10 10 10 10 5 0.085 0.085 0.085 0.085 0.001 Mechanical latch blocks – – – – Terminal numbering in accordance with EN 50005 Disconnection of the contactor or auxiliary contactor, either using an electrical pulse or manually. Terminals protected against accidental contact in accordance with VDE 0106 T.100, VBG4 Frontal selector allows for adaptation in function of the housing of the contactor. For use with CL00...CL10 BEL Cat. no. (2) RMLF ◆ Pack Weight 5 0.082 (2) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency of the control circuit. ◆ 50 Hz 60 Hz DC D G HC J N U Y 24, 32 42, 48 110, 115, 120, 127 220, 230, 240, 380, 400, 415, 440, 480 500, 660/690 24, 32 48, 60 110, 115, 120, 127 208, 220, 240, 277 380, 400, 415, 440, 480 600 24, 32, 36 42, 48 60, 72 110, 120, 125 220, 230, 240, 250 440 Mechanical and mechanical/electrical interlock Side mounted to the contactor BEL02 Technical specifications, see K.35 Dimensions, see K.45 For use with CL00...CL45 CL05...CL10 CL00...CL45 CL05...CL10 Type Mechanical Mechanical Mech./electrical Mech./electrical Cat. no. BELA BEL BELA02 BEL02 Pack Weight 5 5 5 5 0.025 0.025 0.025 0.025 SERIES CL - Accessories BSLR2R Transient voltage suppressor block Directly connected parallel to the coil terminals A1-A2 BETL45C Control circ. AC For use with Type CL00...CL45... R/C AC CL05A...CL10A... R/C DC AC/DC CL...D... CL... Diode Varistor Ue 24V...48V 50V...127V 130V...240V 24V...48V 50V...127V 130V...240V 12V...600V 24V...48V 50V...127V 130V...240V 277V...500V Cat. no. BSLR2G BSLR2K BSLR2R BSLR3G BSLR3K BSLR3R BSLDZ BSLV3G BSLV3K BSLV3R BSLV3U Pack Weight 10 10 10 10 10 10 10 10 10 10 10 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 Time 0.1...2 s. 1.5...45 s. 0.1...2 s. 1.5...45 s. Cat. no. BETL02C BETL45C BETL02D BETL45D Pack Weight Ue (DC) 24V 48V 24V 48V 24V Cat. no. IMRD IMRG IMRFD IMRFG IMSSD IMAMS Pack Electronic timer module Directly connected parallel to the coil terminals A1-A2 Control circ. For use with 24-250V AC/DC CL00 to CL10 Type Delayed ON Delayed OFF IMRD 0.040 0.040 0.040 0.040 Interface module Directly connected parallel to the coil terminals A1-A2 Control circ. 24-250V AC 24-250V DC For use with CL00 to CL10 CL00 to CL45 Type Relay Relay + forced operation Solid state Auto / Manual / Off control IMRC2R 5 5 5 5 5 5 5 5 5 5 Weight 0.060 0.060 0.050 0.050 0.045 0.045 Transient voltage suppressor block to use with interface modules To be plugged inside the interface module or inside the electronic timer module. For use with Type CL00...CL45... R/C CL05A...CL10A... R/C CL...D... CL... Diode Varistor Con. circ. AC/DC 24V...48V 50V...127V 130V...240V 24V...48V 50V...127V 130V...240V 12V...600V 24V...48V 50V...127V 130V...240V Cat. no. IMRC2G IMRC2K IMRC2R IMRC3G IMRC3K IMRC3R IMD1Z IMV3G IMV3K IMV3R Pack Weight 10 10 10 10 10 10 10 10 10 10 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 Cat. no. PTP04 PTP45 PTP08 PTP10 Pack Weight Pole terminal protector IP xxB For use with CL03...CL04... CL45... CL05...CL08... CL09...CL10... Mounting Single pole IPxxB Single pole IPxxB Single pole IPxxB Single pole IPxxB 8 6 8 8 Identification Technical specifications, see K.35 Dimensions, see K.45 Sheets of labels (10 sheets of 260 labels each) Labeling plate base (50 pieces in one pack) EAT260 SPR 1 1 0.050 0.001 SERIES CL - Accessories Alternating current Coils CL...A Cat. no. (1) LB1A ◆ LB3A ◆ LB4A ◆ For use with CL00...CL25 CL03...CL45 CL05...CL10 LB4AN Pack 5 5 5 Weight 0.063 0.102 0.145 Alternating current (V) ◆ C D 50Hz 60Hz F G H 24 42 48 24 48 J K M 110 127 110 120 N R 220 240 230 220 277 S T U V 380 400 W X Y Z 415 440 500 660 690 240 380 480 440 460 600 Alternating current (V) Dual-frequency coil ◆ 1 50/60Hz 24 42 110-115 120 220 230 240 440 48 2 3 4 5 6 7 8 9(2) (1) To complete the catalogue number, replace the symbol ◆ by the corresponding code. (2) Only for CL00 to CL45 Direct current (2) CL...D ◆ Voltage For use with CL00...CL25 CL03...CL45 B 12 D 24 F 42 G 48 H 60 I 72 Cat. no. (1) LB1D ◆ LB3D ◆ Pack 5 5 Weight 0.205 0.276 J K N P R X 110 120 220 230 240 440 125 (1) To complete the catalogue number, replace the symbol ◆ by the corresponding code. Direct current (V) with electronic module (also for use with alternating current) (2) CL...E ◆ Voltage For use with CL05...CL10 D 24 28 F 42 48 Cat. no. (1) LB4E ◆ Pack Weight 1 0.610 H J N Y 60 110 220 440 72 125 250 (1) To complete the catalogue number, replace the symbol ◆ by the corresponding code. (2) Operating limits 0.80 up to 1.10 x Us. For operating limits 0.70 up to1.30 x Us : see page K.12 Contact kits For use with CL00... CL01...3..., CL01...4... CL01...B CL02...3, CL02...4... CL02...B... CL25...3... CL03...,CL03...4... CL03...B... CL04...3..., CL04...4... CL04...B CL45...3... CL05...4... CL05...B... CL06... CL07...3..., CL07...4... CL07...B... CL08...3... CL08...B... CL09... CL10... Number of sets (1) 3 3 4 3 4 3 3 4 3 4 3 4 4 3 3 4 3 4 3 3 Type NO NO 2NO-2NC NO 2NO-2NC NO NO 2NO-2NC NO 2NO-2NC NO NO 2NO-2NC NO NO 2NO-2NC NO 2NO-2NC NO NO Cat. no. V31200B V31201B VB1201B V31202B VB1202B V31225B V31203B VB1203B V31204B VB1204B V31245B V31205B VB1205B V31206B V31207B VB1207B V31208B VB1208B V31209B V31210B Pack Weight 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 (1) One set consists of two fixed contacts, one moving contact and accessory parts. 0.025 0.025 0.035 0.025 0.035 0.035 0.035 0.050 0.035 0.050 0.035 0.080 0.100 0.080 0.090 0.110 0.090 0.110 0.120 0.130 SERIES CL - Technical data Climatic resistance IEC 68-2 General Conformity to standards IEC 947-1 CENELEC HD 419 CEI EN 60947-4-1 UL 508 EN 50005 IEC 947-4-1 NF C 63-110 ASE 1025 CSA 22.2/14 UNE 20109 BS 5424 & 775 NEMA ICS 1 VDE 0660/102 Approvals UL CSA IMQ (up to Ith: 32 A) SETI RINA Lloyds’ Register of Shipping Bureau Veritas 40/125/56 Cyclical tests (humide test) First half-cycle – 40°C – Low temperature + 25°C 72 h – Relative humidity 93 % – Time 12 h + 125°C Second half-cycle ≤ 50 % – Low temperature + 55 % 96 h – Relative humidity 95 % – Time 12 h + 40°C Number of consecutive 95 % cycles 6 56 days Mounting positions Ambient conditions Storage temperature Operation temperature Operating altitude up to 3,000 m Operating altitude from 3,000 to 4,000 m Operating altitude from 4,000 to 5,000 m Continuous tests Cold – Temperature – Time Dry heat – Temperature – Relative humidity – Time Humid heat – Temperature – Relative humidity – Time – 55°C to + 80°C – 40°C to + 60°C Nominal values 90 % Ie 80 % Ue 80 % Ie 75 % Ue With the same pick-up and drop-out voltage. With the same rated power. Terminal capacity and tightening torque CL00 ... CL02 Solid, stranded and finely 2 x 0.5 ... 2.5 stranded without end sleeve (mm2) or 2 x 2.5 ... 6 Finely stranded with or 2 x 1 ... 2.5 without end sleeve (mm2) or 2 x 2.5 ... 6 AWG wires 2 x 20 ... 12 Tightening torque 1.6 Nm 15 Lb x in Solid, stranded and finely stranded without end sleeve (mm2) – Finely stranded with end sleeve (mm2) – Finely stranded without end sleeve (mm2) – AWG wires – Tightening torque – – Solid (mm2) – Stranded (mm2) – Finely stranded without end sleeve (mm2) – Finely stranded with end sleeve (mm2) – AWG wires – Tightening torque – – Solid, stranded and finely – stranded without end sleeve (mm2) – Finely stranded without – end sleeve (mm2) – Finely stranded with – end sleeve (mm2) – AWG wires – – Tightening torque – – CL25 2 x 0.5 .. 2.5 or 2 x 2.5 ... 10 2 x 1 ... 2.5 or 2 x 2.5 ... 10 2 x 20 ... 8 2.2 Nm 20 Lb x in CL03 ...CL04 – – – – – – – CL45 – – – – – – – CL05 ... CL08 – – – – – – – CL09 ... CL10 – – – – – – – – 0.75 ... 16 0.75 ... 16 1 ... 35 1.5 ... 50 – 0.75 ... 16 0.75 ... 16 1 ... 35 1.5 ... 50 – – – – – – 1 ... 16 18 ... 6 1.4 Nm 12 Lb x in 0.75 ... 16 0.75 ... 16 1 ... 16 18 ... 6 1.8 Nm 16 Lb x in 0.75 ... 16 0.75 ... 16 1 ... 35 16 ... 2 4 Nm 35 Lb x in 1 ... 16 1 ... 25 1.5 ... 50 16 ... 2 5.6 Nm 50 Lb x in 4 ... 35 4 ... 35 – 0.75 ... 16 0.75 ... 16 1 ... 25 4 ... 35 – – – – – – – – – – – – – – 1 ... 16 18 ... 6 1.4 Nm 12 Lb x in Max. 16 1 ... 16 18 ... 6 1.8 Nm 16 Lb x in Max. 16 4 ... 35 10 ... 1 5.6 Nm 50 Lb x in Max. 50 ... 35 Max. 16 Max. 16 Max. 16 Max. 16 Max. 6 Max. 6 1.4 Nm 12 Lb x in 1.8 Nm 16 Lb x in 1 ... 25 16 ... 4 4 Nm 35 Lb x in Max. 50 ... 4 Max. 25 ... 16 Max. 35 ... 2.5 Max. 25 ... 16 Max. 35 ... 16 Max. 25 ... 25 Max. 2 ... 12 Max 4 ... 4 4 Nm 35 Lb x in Max. 35 Max. 35 Max. 1 5.6 Nm 50 Lb x in SERIES CL - Technical data Power circuit Three-pole version Rated thermal current Ith at θ ≤ 55°C Rated operational current Ie Rated operational voltage Ue (A) (A) (V) CL00 25 9 690 CL01 25 12 690 CL02 32 18 690 CL25 45 25 690 CL03 45 25 690 CL04 60 32 690 CL45 60 40 690 CL06 90 50 690 CL07 110 65 690 CL08 110 80 690 CL09 140 95 690 CL10 140 105 690 Four-pole version (4 NO and 2 NO + 2 NC) Rated thermal current Ith at θ ≤ 55°C Rated operational voltage Ue CL01 CL02 25 32 690 690 (A) (V) CL03 CL04 45 60 690 690 CL07 CL08(1) CL09(2) 110 110 140 690 690 690 CL05 90 690 (1) 2 NO + 2 NC only (2) 4 NO only Three-pole and four-pole version Rated insulation voltage Ui Maximum continuous current AC1 Frequency limits Making capacity (RMS) (acc. IEC 947) Breaking capacity (RMS) (acc. IEC 947) Ue ≤ 400V Ue = 500V Ue = 690V Short-time current 1 sec. 5 sec. 10 sec. 30 sec. 1 min. 3 min. Recovery time Protection against short-circuits with fuses Coordination type "2" aM gL-gG Without welding aM gL-gG Impedance per pole Power dissipation per pole AC1 AC3 Insulation resistance Between adjacent poles Between poles and earth Between input and output CL00 1000 25 25..400 450 CL01 1000 25 25..400 450 CL02 CL25 CL03 1000 1000 1000 32 45 45 25..400 25..400 25..400 450 450 550 CL04 1000 60 25..400 550 CL45 CL05 1000 1000 60 90 25..400 25..400 550 1000 CL06 CL07 1000 1000 90 110 25..400 25..400 1000 1000 CL08 1000 110 25..400 1000 CL09 1000 140 25..400 1280 CL10 1000 140 25..400 1280 (A) (A) (A) 250 250 130 250 250 130 250 250 130 350 320 170 450 450 205 450 450 205 450 450 205 920 920 780 920 920 780 920 920 780 920 920 780 1050 1050 950 1050 1050 950 (A) (A) (A) (A) (A) (A) (min.) 455 205 144 85 60 35 10 455 205 144 85 60 35 10 570 254 180 104 74 46 10 630 280 200 115 80 50 10 1010 450 320 185 130 90 10 1010 450 320 185 130 90 10 1265 450 400 230 165 100 10 1580 565 500 290 205 120 10 1580 710 500 290 205 120 10 2530 1130 800 460 325 185 10 2530 1130 800 460 325 185 10 3300 1485 1050 600 430 250 10 3300 1485 1050 600 430 250 10 10 25 12 35 20 35 25 50 25 63 35 63 40 63 40 100 50 100 80 160 80 160 125 200 160 200 (A) (A) (mΩ) 8 10 2.35 8 10 2.35 16 25 2.41 20 35 1.65 20 35 1.28 20 35 1.28 25 50 0.95 35 80 0.85 40 80 0.85 50 100 0.86 50 100 0.86 80 160 0.76 80 160 0.76 (W) (W) 1.47 0.19 1.47 0.34 2.46 0.78 3.34 1.03 2.59 0.80 4.6 1.31 3.42 1.52 6.89 1.36 6.89 2.12 10.4 3.63 10.4 5.5 14.89 14.89 6.86 8.37 (MΩ) (MΩ) (MΩ) >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 >10 (V) (A) (Hz) (A) (A) (A) >10 >10 >10 SERIES CL - Technical data Control circuit Three-pole and four-pole contactors Alternating current Rated insulation voltage Ui (V) Standard voltages Us 50 Hz (V) Standard voltages Us 60 Hz (V) Voltage operating limits monofrequency coils Operating xUs Pick-up xUs Seal xUs Voltage operating limits coils 50/60 Hz Operating 50 Hz xUs Operating 60 Hz xUs Pick-up 50 Hz xUs Pick-up 60 Hz xUs Seal 50 Hz xUs Seal 60 Hz xUs Consumption monofrequency coils Seal (VA) Pick-up (VA) Consumption bifrequency coils Seal (50 Hz/60 Hz) (VA) Pick-up (50 Hz/60 Hz) (VA) Thermal power dissipation (50 Hz/60 Hz)) (W) Power factor Magnetic circuit closed (cos ϕ) Magnetic circuit open (cos ϕ) Opening and closing times Values between + 10 % Us and – 20 % Us Making time on excitation (NO contact) (ms) Breaking time on de-excitation (NO contact) (ms) Values at Us Making time on excitation (NO contact) (ms) Breaking time on de-excitation (NO contact) (ms) Mechanical endurance Monofrequency coils 106 ops. Bifrequency coils (at 50 Hz) 106 ops. Maximum rate Monofrequency coils no load ops./h AC1 at rated power ops./h AC2 at rated power ops./h AC3 at rated power ops./h AC4 at rated power ops./h Bifrequency coils no load ops./h Direct current Rated insulation voltage Ui (V) Standard voltages Us (V) Operating limits Operating xUs Pick-up xUs Drop-out xUs Consumption Magnetic circuit closed (W) Magnetic circuit open (W) Opening and closing times Values between + 10 % Us and – 20 % Us Making time on excitation (NO contact) (ms) Breaking time on de-excitation (NO contact) (ms) Values at Us Making time on excitation (NO contact) (ms) Breaking time on de-excitation (NO contact) (ms) Mechanical endurance 106 ops. Maximum rate No load ops./h AC1 and AC3 at rated power ops./h AC4 at rated power ops./h CL00...CL25 1000 24...690 24...600 CL03...CL45 1000 24...690 24...600 CL05...CL08 1000 24...690 24...600 CL09...CL10 1000 24...690 24...600 0.8...1.1 0.6...0.8 0.35...0.55 0.8...1.1 0.65...0.8 0.4...0.6 0.8...1.1 0.65...0.8 0.4...0.6 0.8...1.1 0.65...0.8 0.4...0.6 0.8...1.1 0.85...1.1 0.5...0.8 0.65...0.85 0.3...0.55 0.35...0.35 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 0.8...1.1 0.85...1.1 0.6...0.8 0.7...0.85 0.35...0.60 0.4...0.6 6 45 9 88 15.5 191 15.5 191 7/5 54 / 35 2 / 1.7 11.4 / 11 120 / 105 (1) 2.8 / 3.3 20 / 15 245 / 215 4.5 / 3.9 20 / 15 245 / 215 4.5 / 3.9 0.39 0.82 0.31 0.76 0.35 0.64 0.35 0.64 6...20 6...13 7...25 5...25 9...35 9...15 9...35 9...15 8...20 6...13 10...19 5...25 15...30 9...15 15...30 9...15 15 10 15 10 15 8 15 8 9000 1200 1000 1200 360 3600 9000 1200 1000 1200 360 3600 9000 1200 1000 1200 200 3600 5000 1200 750 600 200 3600 CL00D...CL25D CL03D...CL45D CL05E...CL08E CL09E...CL10E 1000 1000 1000 1000 12...440 12...440 24...440 24...440 0.8...1.1 0.45...0.65 0.15...0.3 0.8...1.1 0.45...0.65 0.15...0.3 0.8...1.1 0.70...0.80 0.4...0.6 0.8...1.1 0.70...0.80 0.4...0.6 5.5 5.5 8 8 10 170 10 170 35...65 6...15 35...70 40...65 60...80 40...50 60...80 40...50 35...45 7...12 15 40...55 30...65 15 50...60 55...60 12 50...60 55...60 12 3600 1200 360 3600 1200 360 2500 1200 200 2500 600 200 (1) for CL45 : 125 / 110 SERIES CL - Dimensional drawings Three-pole and four-pole AC contactors Three-pole and four-pole DC contactors CL00A3 . . T CL01A3 . . T CL01A4 . . T CL02A3 . . T CL02A4 . . T CL25A300T CL25A310T CL25A301T A 85 85 85 85 85 87 87 87 CL03A3 . . M CL03A4 . . M CL04A3 . . M CL04A4 . . M CL45A300M CL45A311M B – – – – – – 29 29 CL00D3 . . T CL01D3 . . T CL01D4 . . T CL02D3 . . T CL02D4 . . T CL25D300T A – – – – – 29 Three-pole AC contactors A 115 115 115 115 – 117 CL03D3 . . M CL03D4 . . M CL04D3 . . M CL04D4 . . M CL45D300M Three-pole DC contactors CL06A3 . . M CL07A3 . . M CL08A3 . . M CL06E3 . . M CL07E3 . . M CL08E3 . . M CL09A3 . . M CL10A3 . . M CL09E3 . . M CL10E3 . . M Four-pole AC contactors Four-pole DC contactors CL05A4 . . M CL07A4 . . M CL05AB . . M CL07AB . . M CL08AB . . M CL05E3 . . M CL07E3 . . M CL05EB . . M CL07EB . . M CL08EB . . M CL09A4 . . M CL09E4 . . M SERIES CL - Dimensional drawings Front mounting auxiliary contact blocks Electronic timer block CL00...CL25 Voltage suppressor block CL00...CL25 BCLF Lateral mounting auxiliary contact blocks CL03...CL45 CL03...CL45 CL05...CL10 BRLL BCLL CL05...CL10 Pneumatic timer block BSLR BSLDZ BSLV BTL02 BTL45 BTLF Mechanical latch block RMLF Interface modules CL00...CL25 CL03...CL45 Mechanical / mechanical-electrical interlock BELA BEL BELA02 BEL02 CL05...CL10 IMR◆ IMRF◆ IMSSD IMAMS