ENERGY STAR ® Power and Performance Data Sheet
Dell PowerEdge T710 featuring 1100W Power Supply
System Characteristics
Form Factor
Available Processor Sockets
Tower
2
Available DIMM Slots / Max Memory Capacity
18/192 GB
ECC and/or Fully Buffered DIMMs
Yes
Available Expansion Slots
6 PCI-E
Minimum and Maximum # of Hard Drives
0 to 16
Redundant Power Supply Capable?
Yes
Power Supply Make and Model
Dell Energy Smart L1100A-SO
1100
Power Supply Output Rating1 (watts)
Minimum and Maximum # of Power Supplies
1 or 2
Input Power Range (AC or DC)
100-240VAC
Power Supply Efficiency at Specified Loadings1
84.9%@10%, 90.3%@20%, 92.6%@50%, 90.3%@100%
Power Supply Power Factor at Specified Loadings1
0.80@10%, 0.91@20%, 0.97@50%, 0.99@100%
Operating Systems Supported2
Microsoft Windows® Server 2003 and 2008
Microsoft Windows Essential Business Server 2008
Microsoft Windows Small Business Server 2008
Red Hat Enterprise Linux 4 and 5
Citrix XenServer 5.x3
Vmware ESXi 3.53
SUSE Linux Enterprise Server 10 and 11
Installed Operating System for Testing
Microsoft Windows Server 2008
Mi
ft Wi d
E
ti l B i
1. Power supply information is for a single power supply only.
S
2008
2. Available operating systems as shipped configurations from the factory.
3. Minimum as shipped configuration is installed SD disk.
System Configurations
Minimum
Typical
Maximum
2, Intel Xeon L5520
2, Intel Xeon E5520
2, Intel Xeon X5570
2 DIMM, 1 GB ea.
12 DIMMs, 2 GB each
12 DIMMs, 16 GB each
1 HDD
8 HDDs / 1 DVD
16 HDDs / 1 DVD/RW /
1 TBU
4 integrated 1 Gb NICs
minimum +
2 Dual Port 1Gb NICs
minimum +
2x Dual Port 10Gb NICs
+
2x 10Gb NICs
Configuration ID
Processor Information
Memory Information
Internal Storage
I/O Devices
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / Accessories
Power Data
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only)
1
2
2
Yes
Yes
Yes
SAS 6i/R
iDRAC6 Express
SAS 6i/R
iDRAC6 Enterprise
PERC 6/E
PERC 6i/R
SAS 6i/R integrated
iDRAC6 Enterprise
Minimum
Typical
Maximum
Category D: Managed Dual Installed Processor (2P) Servers
154
278
718
Measured Idle Power (watts)
106.6
197.5
403.9
Power at Full Load1 (watts)
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
218.0
322.3
Sandra Dhrystone isse 4.2
115 V/60 Hz
499.2
Range of Total Estimated Energy Usage ** (kWh/year)
1,868 to 3,819
3,460 to 5,647
7,076 to 8,746
WWW.Dell.com/CALC
Link to Detailed Power Calculator (if available)
1. Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the highest average,
sustained power possible for other workloads.
2. Estimated kWh/year gives the absolute range of energy use you could expect from continuous operation (24x7x365) and ranges from 100% idle usage to 100% full-load operation.
The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0). Closer approximations may be
found by using established power calculators and specific information about the intended operating environment (e.g., average time at Idle, data center PUE, etc.).
Benchmark #1
Power and Performance for Benchmark #1
Minimum
Avg. Power Measured During Benchmark Run
Typical
Maximum
Sandra Dhrystone isse 4.2
Benchmark Used and Type of Workload
218.0
322.3
Benchmark Performance Score
114
114
120
Power Performance Ratio (perf score/avg. power)
0.52
0.35
0..24
Link to Full Benchmark Report (Where Available)
499.2
ENERGY STAR Power and Performance Data Sheet
Dell PowerEdge T710 featuring 1100W Power Supply
Page 2 of 2
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Enabled on
Shipment
End-User Enabling
Required
Yes
Yes
Yes
Yes
No
No
Yes
No
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Yes, +/- 5% for 20%-100% of max PSU load
Input Air Temp Available & Accuracy?
Yes, +/- 2%
Processor Utilization Available?
Yes
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
Averaging method and time period
Thermal Information 1
Total Power Dissipation (watts)
Delta Temperature at Exhaust at 35C Peak Temp. (˚C)
Airflow at Maximum Fan Speed (CFM) at 35C Peak
Temp.
Airflow at Nominal Fan Speed (CFM) at 25C Nominal
Temp.
IPMI
Power: 1 min running
average of 2s interval
l
T
t
Minimum
Typical
Maximum
218.0
322.3
499.2
5.1
6.4
12.0
88 (From exhaust fans,
auto fan control)
45 (From exhaust fans,
auto fan control)
88 (From exhaust fans,
auto fan control)
45 (From exhaust fans,
auto fan control)
103.5 (From exhaust
fans, auto fan control)
66.2 (From exhaust
fans, auto fan control)
1. ASHRAE Extended Environmental Envelope Final August 1, 2008. Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5.
Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C