RadioRA 2 Visor Controls

advertisement
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
RadioRA® 2 Visor Controls allow lights,
shades / draperies, and other equipment to
be controlled from the car with just a touch
of a button on a Visor Control Transmitter or
a HomeLink® compatible visor control. Up to
ten (10) Transmitters can be used with a Visor
Control Receiver.
The Receiver provides two (2) Contact Closure
Inputs (CCI) for integration with other systems
and one (1) CCI for security systems. The CCIs
can be configured to accept maintained or
momentary contact closures. The security input
is always a maintained CCI.
The Receiver also has four (4) maintained or
momentary Contact Closure Outputs (CCO) to
control up to four (4) garage doors or motorized
gates.
RR-VCRX-WH
Visor Control Receiver
Pre-printed and blank labels are included with
the Visor Controls for naming scenes or buttons
on both the Receiver and the Transmitter.
Model Numbers
RR-VCRX-WH*
Visor Control Receiver
RR-VCRX-WHBA*
Visor Control Receiver for Brazil
LR-3B-H-SW**
Visor Control Transmitter
*Only available in White (WH).
**Only available in Snow (SW).
www.lutron.com/radiora2
LR-3B-H-SW
Visor Control Transmitter
HomeLink and the HomeLink
Compatible logo are registered
trademarks of Johnson Controls.
Lutron® | 1
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
Specifications
Model Numbers
RR-VCRX-WH, RR-VCRX-WHBA, LR-3B-H-SW
Power
Receiver: 9 V
300 mA
DC adapter:
Input: 120 V
60 Hz 6.5 W
Output: 9 V
300 mA
Transmitter: 6 V
10 mA (2 - CR2032, included – 10 year lifetime)
Typical Power
Consumption
1.6 W
Test conditions: two LEDs on (two presets active), powered by the 9 V
adapter supplied, no CCOs or CCIs active.
Regulatory Approvals
DC adapter: UL Listed for U.S. and Canada, NOM
Receiver / Transmitter: FCC, IC, COFETEL, ANATEL
Environment
Receiver:
Ambient operating temperature: 32 °F to 140 °F (0 °C to 60 °C),
0% to 90% humidity, non-condensing. Indoor use only.
Transmitter:
Ambient operating temperature: -40 °F to 235 °F (-40 °C to 113 °C),
0%-90% humidity, non-condensing. Meets the Society of Automotive
Engineers (SAE) temperature standards.
Communications
Visor Controls communicate with the system through Radio Frequency (RF).
The Receiver must be located within 30 ft (9 m) of a Repeater. The typical
operating distance between a Receiver and a Transmitter is 150 ft (46 m).
System devices operate on frequencies between 431.0 MHz and 437.0 MHz.
ESD Protection
Tested to withstand electrostatic discharge without damage or memory
loss, in accordance with IEC 61000-4-2.
Surge Protection
Tested to withstand surge voltages without damage or loss of operation,
in accordance with IEEE C62.41-1991 Recommended Practice on
Surge Voltages in Low-Voltage AC Power Circuits.
Mounting
Mount Receiver on a wall, ceiling, or level surface using the two #6 (M3)
screws provided. Clip Transmitter to a vehicle’s visor.
Connections
2 Contact Closure Inputs, 1 security input, and 4 momentary or
maintained Contact Closure Outputs.
Warranty
1 Year Limited Warranty. http://www.lutron.com/resiinfo
Design Features
Each output can be controlled locally at the
Receiver or remotely by a Transmitter or
keypad button.
•
The Receiver ‘Keypad’ or ‘Inputs’ buttons can
be programmed to light and shades / draperies.
•
2 | Lutron®
Full or Flash security options.
•
T
he Transmitter can remotely control the
‘Keypad’, ‘Security Input’, and ‘Outputs’
buttons on the Receiver.
•
24/7 Technical Support—800.523.9466
product specifications
03.10.12
369-224e
RadioRA 2 Visor Controls
®
Dimensions
All dimensions are shown as in
(mm)
Receiver (Side)
Receiver (Front)
6 1⁄4
(159)
Visor Control Receiver
Security Input
Inputs
Full
Flash
Outputs
Keypad
5 1⁄4
(133)
1/4
(6)
Visor Transmitter
2 3⁄4
(70)
Learn
Power
Inputs
9V
1
Outputs
Full
2 Flash C
1
C
2
C
3
C
Mounting Holes
3 3⁄4
(95)
4
C
1 1⁄16
(27)
4 1⁄4
(108)
Transmitter (Side)
Transmitter (Front)
1 1⁄2
(38)
3 1⁄4
(81)
www.lutron.com/radiora2
3/4
(19)
Lutron® | 3
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
Mounting
Receiver
Vertical
Horizontal
Ceiling
Wall
#6 (M3) screw
recommended
(2 included)
Level Surface
Transmitter
Vehicle Visor
4 | Lutron®
24/7 Technical Support—800.523.9466
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
Operation
Receiver
Visor Control Receiver
Input LEDs
Display status of Inputs.
Security Input
Inputs
Full
Flash
Outputs
Input Buttons
Press to test CCI programming.
Keypad
Inputs
Security Input
Full
Visor Transmitter
Security Input LEDs
Turn on when security
mode is activated.
Learn
Flash
Power
Inputs
9V
1
2
Outputs
Full
Flash C
1
C
2
C
3
C
4
C
Outputs
Output LEDs
Display which
CCOs are
active.
Keypad
Keypad Buttons
Press to test keypad
programming.
Visor Transmitter
Learn
Keypad LEDs
Display status of lights and
shades / draperies programmed
to the ‘Keypad’ buttons.
Output Buttons
Press to test
CCOs.
Learn LED
Flashes to
indicate that the
Receiver is in
Learn mode.
Security Input Buttons
Press and hold to test
Security programming.
Learn Button
Press and hold
for 3 seconds
to enter Learn
mode.
Labels
Place pre-printed or custom
labels in depressions to name
scenes / buttons.
Transmitter
Labels
Place pre-printed or custom
labels in depressions to name
scenes / buttons
Visor Control Transmitter Buttons
Press to activate functions remotely.
www.lutron.com/radiora2
Lutron® | 5
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
Connections
Receiver (Top)
RF range:
To repeater 30 ft (9 m)
To Transmitter 150 ft (46 m)
Antenna
Receiver (Bottom)
Contact Closure Inputs (CCI)
Dry contacts only.
ON saturation: <1 V
at 2 mA
OFF leakage: <1 µA at 9 V
Minimum pulse time: 40 ms
Common - C
Contact Closure Outputs (CCO)
Max Voltage / Current: See Relay Contact Ratings below.
IEC PELV / NEC® Class 2
Minimum close time: 500 ms
1 - Output 1
C - Common 1
2 - Output 2
C - Common 2
3 - Output 3
C - Common 3
4 - Output 4
C - Common 4
(all inputs)
Security - Full
Flash
Input 2 - 2
Input 1 - 1
9V
Power Jack (to adapter)
IEC PELV / NEC® Class 2
Contact Closure Terminal Blocks
Use IEC PELV / NEC® Class 2 cable Maximum 1000 ft (305 m)
Each terminal holds up to one 16 AWG (1.0 mm2)
or two 18 AWG (0.75 mm2) or smaller wire.
Relay Contact Ratings
Voltage
Up to 30 V
Up to 30 V
Up to 60 V
6 | Lutron®
Resistive
Load
1A
1A
0.5 A
Inductive
Load
0.2 A
0.1 A
Do not use.
24/7 Technical Support—800.523.9466
product specifications
369-224e
03.10.12
RadioRA 2 Visor Controls
®
Wiring Diagram
Dry
Contact
Closure
Input
C
Common
Input 2
(e.g. motion sensor)
Security
System
O
Output 1
C
Common 1
Output
Device
(e.g. garage door)
Security
S
C
Common
www.lutron.com/radiora2
Lutron® | 7
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Los controles de visera RadioRA® 2 permiten
controlar luces, cortinas y demás equipos desde
el automóvil con tan sólo tocar un botón de un
transmisor del control de visera o de un control
de visera compatible con HomeLink®. Se pueden
utilizar hasta diez (10) transmisores con
un receptor de control de visera.
El receptor cuenta con dos (2) entradas de
contacto seco (CCI) para la integración con
otros sistemas y una (1) entrada de contacto
seco para sistemas de seguridad. Las entradas
CCI se pueden configurar para aceptar cierres
sostenidos o momentáneos. La entrada de
seguridad siempre es sostenida.
Además, el receptor tiene cuatro (4) salidas
de contacto seco (CCO) sostenidos o
momentáneos para controlar hasta cuatro (4)
puertas de garaje o portones motorizados.
RR-VCRX-WH
Receptor de control
de visera
Los controles de visera vienen con etiquetas
preimpresas y otras en blanco para identificar
escenas o los botones del receptor transmisor.
Números de referencia
RR-VCRX-WH*
Receptor de control de visera
RR-VCRX-WHBA*
Receptor de control de visera para Brasil
LR-3B-H-SW**
Transmisor de control de visera
LR-3B-H-SW
Transmisor de control
de visera
HomeLink y el logotipo HomeLink
Compatible son marcas registradas
de Johnson Controls.
*Disponible sólo en color blanco (WH).
**Disponible sólo en color blanco nieve (SW).
8 | Lutron®
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Especificaciones
Números de referencia
RR-VCRX-WH, RR-VCRX-WHBA, LR-3B-H-SW
Alimentación
Receptor: 9 V
300 mA
Adaptador de CC:
Entrada: 120 V
60 Hz 6,5 W
Salida: 9 V
300 mA
Transmisor: 6 V
10 mA (2 - CR2032, incluidas – vida útil de 10 años)
Consumo típico
de potencia
1,6 W
Condiciones de prueba: dos indicadores LED encendidos (dos estados
predeterminados activos), alimentado por el adaptador de 9 V
provisto,
sin entradas CCI ni salidas CCO activas.
Certificaciones
Adaptador de CC: listado en UL para EUA y Canadá, NOM
Receptor/transmisor: FCC, IC, COFETEL, ANATEL
Condiciones ambientales
Receptor:
Temperatura ambiente de operación: 0 °C a 60 °C (32 °F a 140 °F), humedad de
0% a 90%, sin condensación. Sólo para uso en interiores.
Transmisor:
Temperatura ambiente de operación: -40 °C a 113 °C (-40 °F a 235 °F),
humedad de 0% - 90%, sin condensación. Cumple con las normas de temperatura
de Society of Automotive Engineers (SAE).
Comunicaciones
Los controles de visera se comunican con el sistema a través de radiofrecuencia
(RF). El receptor debe ubicarse a no más de 9 m (30 pies) de un repetidor. La
distancia típica de operación entre receptor y transmisor es de 46 m (150 pies). Los
dispositivos del sistema funcionan en frecuencias que oscilan entre los 431,0 MHz
y 437,0 MHz.
Protección
contra descargas
electrostáticas (ESD)
Las botoneras se prueban según IEC 61000-4-2 por resistencia a descargas
electrostáticas sin daño ni pérdida de memoria.
Protección contra
sobrevoltajes
Las botoneras se prueban según IEEE C62,41-1991 por resistencia a sobrevoltajes
sin daño ni pérdida de operación. Prácticas recomendadas para transitorios
de voltaje en circuitos de potencia de corriente alterna de bajo voltaje.
Montaje
Monte el receptor sobre una pared, el cielo raso o una superficie plana con los
dos tornillos M3 (No. 6) suministrados. Sujete el transmisor con el clip a una
visera del vehículo.
Conexiones
2 entradas de contacto seco, 1 entrada de seguridad y 4 salidas de contacto
seco momentáneo o sostenida.
Garantía
Garantía limitada por un año. http://www.lutron.com/resiinfo
Características de diseño
• C
ada salida se puede controlar en forma local
desde el receptor o en forma remota desde
un transmisor o un boton de una botonera.
• Los botones de la “Keypad” (botonera) o de
“Inputs” (entradas) del receptor se pueden
programar para controlar luces y cortinas.
• Opciones de seguridad de Permanentemente
encendido o Parpadeo.
www.lutron.com/radiora2
• E
l transmisor puede controlar en forma remota los
botones de la “Keypad” (botonera), de “Security
Input” (entrada de seguridad) y de “Outputs”
(salidas) del receptor.
Lutron® | 9
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Dimensiones
Todas las dimensiones se muestran en mm
(pulg)
Receptor (vista lateral)
Receptor (vista frontal)
159
(6 1/4)
Visor Control Receiver
Security Input
Inputs
Full
Flash
Outputs
Keypad
133
(5 1/4)
6
(1/4)
Visor Transmitter
70
(2 3/4)
Learn
Power
Inputs
9V
1
Outputs
Full
2 Flash C
1
C
2
C
3
C
4
Orificios de montaje
95
(3 3/4)
C
27
(1 1⁄16)
108
(4 1/4)
Transmisor (vista lateral)
Transmisor (vista frontal)
38
(1 1/2)
81
(3 1/4)
10 | Lutron®
19
(3/4)
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Montaje
Receptor
Vertical
Horizontal
Cielo raso
Pared
Se recomienda utilizar tornillos M3 (No. 6)
(se incluyen 2)
Superficie plana
Transmisor
Visera del vehículo
www.lutron.com/radiora2
Lutron® | 11
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Operación
Receptor
Visor Control Receiver
Security Input
Inputs
Full
Indicadores LED de entrada
Muestran el estado
Botones de entrada
de las entradas.
Presione para comprobar la programación
de las entradas de contacto seco.
Flash
Outputs
Keypad
Inputs
Security Input
Full
Visor Transmitter
Learn
Flash
Power
Inputs
9V
1
2
Outputs
Full
Flash C
1
C
2
C
3
C
Indicadores
LED de salida
Muestran qué
las salidas de
contacto seco
están activas.
4
C
Outputs
Keypad
Visor Transmitter
Indicadores LED de la botonera
Muestran el estado de las luces
y cortinas programadas para los
botones de la “botonera”.
Botones de salida
Presione para comprobar las
salidas de contacto seco.
Transmisor
Botones de entrada de seguridad
Mantenga presionado para
comprobar la programación
de seguridad.
Botones de la botonera
Presione para comprobar la
programación de la botonera.
Learn
Indicador LED de memorización
Parpadea para indicar que
el receptor está en modo
de memorización.
Indicadores LED de entrada
de seguridad
Se encienden cuando se activa
el modo de seguridad.
Botón de
memorización
Mantenga
presionado durante
3 segundos para
ingresar al modo
de memorización.
Etiquetas
Coloque las etiquetas preimpresas
o personalizadas en las cavidades para
identificar las escenas o los botones.
Etiquetas
Coloque las etiquetas preimpresas o personalizadas en
las cavidades para identificar las escenas o los botones.
Botones del transmisor de control de visera
Presione para activar las funciones en forma remota.
12 | Lutron®
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Conexiones
Receptor (vista superior)
Alcance de RF:
9 m (30 pies) al repetidor
46 m (150 pies) al transmisor
Antenna
Receptor (vista inferior)
Entradas de contacto seco (CCI)
Sólo contactos secos.
Saturación en estado activo:
<1 V a 2 mA
Fuga en estado inactivo:
<1 µA a 9 V
Duración mínima del pulso: 40 ms
Salidas de contacto seco (CCO)
Corriente/voltaje máximo: Consulte las
especificaciones de los contactos de relé
que figuran a continuación.
IEC PELV / NEC® Class 2
Duración mínima de cierre: 500 ms
Común - C
(todas las entradas)
Seguridad - Completo
Parpadeo
Entrada 2 - 2
Entrada 1 - 1
1 -Salida 1
C-Común 1
2 -Salida 2
C-Común 2
3 -Salida 3
C-Común 3
4 -Salida 4
C-Común 4
9V
Enchufe de alimentación
(al adaptador)
IEC PELV / NEC® Class 2
Conectores de contacto seco
Utilice un cable IEC PELV / NEC® Class 2
Máximo: 305 m (1 000 pies)
Cada terminal admite hasta un cable de 1,0 mm2 (16 AWG),
dos cables de 0,75 mm2 (18 AWG) o cables más pequeños.
Especificaciones de los contactos de relé
Voltaje
Hasta 30 V
Hasta 30 V
Hasta 60 V
Carga
resistiva
1A
1A
0,5 A
www.lutron.com/radiora2
Carga
inductiva
0,2 A
0,1 A
No utilizar.
Lutron® | 13
especificaciones del producto
369-224e
03.10.12
Controles de visera RadioRA 2
®
Diagrama de cableado
Entrada de
cierre de
Común
contacto
Entrada 2
seco
(por ejemplo: sensor
de movimiento)
Sistema
de seguridad
14 | Lutron®
Salida 1
Común 1
Dispositivo
de salida
(por ejemplo:
puerta de garaje)
Seguridad
Común
Soporte técnico las 24 horas del día, los 7 días de la semana—800.523.9466
Download