Enclosed Circuit Breakers Enclosures — Type 1 Selection Dimensions Figure 1 Figure 3 Figure 2 Type 1 Number of Poles Weight Lb./Ship. Dimensions (inches) Package A B C D E F Maximum Current Catalog Rating Number K.O. Dimensions 6 Plcs. 2 Plcs. G H 11⁄16 — — 41⁄2 15⁄16 — — 41⁄2 15⁄16 — — 6 13⁄16 — — 7 ⁄8, 11⁄8, 13⁄8, ⁄8, 11⁄8, 13⁄8, 13⁄4, 2 13⁄4, 2 QP, QPH, 1 1–2 0060 E0204ML1060S a cg HQP 1 QP, QPH, 3 0 100 HQP E0303ML3100S a cf 1 BQ, BQH, 0 3 100 HBQ EB3100S cf 1 NGG GG0121FN/SN 6 Breaker Frame 2 ED2, ED4, ED6, 0 2–3 100 HED4 ENCLOSED CIRCUIT BREAKERS Fig. No. 2 ED4, ED6, HED4, 0 2–3 125 CED6 2 1 FXD6, FD6, FXD6, 1 ⁄8, 13⁄8, F6N1S b 033 3813⁄32 1115⁄32 051⁄16 33 08 133⁄64 13⁄4, 2, FD6, HFD6, HFXD6, 2–3 0250 b F6N1F 21⁄2, 3 HHFD6, CFD6 11⁄8, 13⁄8, 13⁄4, 20, 21⁄2, 3 3 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 h 3 LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6, SCJD6, SCLD6, CJD6, CLD6 h 3 3 125 00 071⁄8 051⁄8 033⁄8 0 0 0 0 8 171⁄8 32 171⁄8 12 20 E2N1S ci E2N1F ci 008 008 1623⁄32 071⁄2 171⁄2 081⁄2 CED6N1S cei CED6N1F cei 014 014 2115⁄32 0719⁄32 057⁄64 221⁄4 081⁄2 057⁄64 0 71⁄8 71⁄8 83⁄4 053⁄4 41⁄4 141⁄8 43⁄4 141⁄8 4 16 051⁄16 051⁄16 033⁄4 0 0 1345⁄64 051⁄4 1 1345⁄64 051⁄4 1 181⁄4 181⁄4 051⁄4 1 051⁄4 1 7 2–3 0400 J6N1 b 120 413⁄16 2227⁄64 1045⁄64 37 181⁄4 25⁄64 — — 2–3 0600 LD6N1 b 101 46 2227⁄64 1045⁄64 42 181⁄4 25⁄64 — — LMXD6, LMD6, 0 2–3 800 HLMXD6, HLMD6 LMD1 b 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — — MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6, SCND6 2–3 1200 MND61 b 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — — h PD6, PXD6, HPD6, HPXD6, CPD6, RD6, SPD6, SHPD6, RXD6, HRD6, HRXD6 3 2000 PRD6N1 n 350 90 32 — — — — — h — 2-3 016 For inches / millimeters conversion, see Application Data section. All above enclosures are suitable for use as service entrance devices n Built to order. Allow 2–3 weeks for delivery. 6-8 a Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”. bNeutral not included. Order as separate item from table on next page. cNeutral included in enclosure. dSurface mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 28 eUse for 110-125 ampere ED4, ED6, or HED4 circuit breakers. not accept breaker with shunt trip. gWill not accept 2-pole GFP or breaker with shunt trip. hIncludes 100% rated breakers. i Enclosure will accept shunt trip and other internal accessories except GFP. fWill Product Category MCCB Enclosed Circuit Breakers Enclosures — Type 1 Selection Dimensions Figure 4 Figure Number Breaker Frame Number of Poles Maximum Current Catalog Rating Number QJ2, QJH2, 2–3 225 QH2-H 4 EB3225S EB3225F Weight Lb./Ship. Dimensions (inches) Package A B C D E F G H 27 101⁄8 27 101⁄8 51⁄4 213⁄16 213⁄8 23⁄8 27 101⁄8 281⁄8 111⁄4 51⁄4 213⁄16 213⁄8 23⁄8 15 J K 3 3 20 51⁄16 23⁄4 23⁄4 20 51⁄16 23⁄4 23⁄4 L M N P 41⁄2 41⁄2 Neutrals Neutral Catalog Number Enclosure Catalog Number Neutral Cable Capacity and Wire Range N125GG GG0121SN/FN (1 pc.) #14-2/0 Cu/Al, (1 pc.) #1-300 kcmil Cu/Al Grd. Lug (1 pc.) #12 - #4 Cu/Al (3 pcs.)#12 - #10 Cu/Al W53045 E2N1(S)(F) CED6N1(S)(F) d N250 F6N1(S)(F) W63623 (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al (1 pc.) #6–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al (1 pc.) #1/0–750 kcmil Cu/Al or (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al W60992 J6N1 W60993 LD6N1 ENCLOSED CIRCUIT BREAKERS (1 pc.) #4 - 2/0 Cu/Al (1 pc.) #1 - 300 kcmil Cu/Al Gnd. Lug (1pc.) #14 - #4 & (3 pcs.) #14 - #10 Cu or (1 pc.) #12 - #4 & (3 pcs.) #12 - #10 Al 6 N225QJ EB3225(S)(F) (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al LMD1 (4 pcs.) 250 kcmil–500 kcmil Cu/Al i Grd. Lug (1 pc.) #6–300 kcmil Cu/Al MND61 N2000 PRD6N1 (6 pcs.) #3/0–750 kcmil Cu/Al Grd. Lug (2 pcs.) #3/0–750 Cu/Al 200% Neutrals (For Type 1, 3R, 4/4X and 12 Enclosures) Neutral Catalog Number Enclosure Catalog Number N2250 F6N1(S)(F) f Neutral Cable Capacity and Wire Range W60993 J6N1 g W63623 LD6N1 h (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6-250 kcmil Cu/Al For inches / millimeters conversion, see Application Data section. a Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”. bNeutral not included. Order as separate item from table on next page. Product Category MCCB (2 pcs.) #4–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al cSurface mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model. dUse for 110-125 ampere ED4, ED6, or HED4 circuit breakers. eWill not accept breaker with shunt trip. fAlso for use with Type 3R, 12, 12K & 4X enclosures (Catalog numbers F6N3R, F6N12, F6N12K & FD6SS4). gAlso for use with Type 3R, 12 & 4X enclosures (Catalog numbers J6N3R, J6N12, & LD6SS4). hAlso for use with Types 3R and 12 enclosures (Catalog numbers LD6N3R & LD6N12). iFor 600 MCM neutral cable (3) in, (3) out (#4–600 kcmil Cu/Al) use catalog number W411239 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 6-9 Enclosed Circuit Breakers Enclosures — Type 3R Selection Figure 2 Figure 1 Figure 3 Type 3R Number of Poles ENCLOSED CIRCUIT BREAKERS 6 Figure Breaker Number Frame Maximum Current Catalog Rating Number Weight Lb./Ship. Dimensions (inches) Package A B C D 2 QP, QPH 1–2 0060 W0204ML1060 0 2 QPP, QPPH, HQPP 0225 W0406ML1225CU 2 QP, QPH, HQP 3 2 BQ, BQH, HBQ 3 3 0050 100 2 NGG 2-3 5 ED2, ED4, ED6, HED4, HED6 2–3 5 CED6, ED2, ED4, ED6 2–3 0125 CED6N3R 1 FXD6, FD6, FXD6, FD6, HFD6, HFXD6, HHFD6, CFD6 2–3 0250 1 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 f 2–3 0400 LD6, LXD6, LXD6H, HLD6, HLXD6, HHLD6, HHLXD6, CJD6, CLD6, SCJD6, SLD6, SHLD6 f 1 1–4 28 081⁄8 051⁄8 043⁄8 — 101⁄2 045⁄16 20 0 0 024 231⁄8 W0303ML3100 00 9 17 ⁄8 WB3100 d 00 9 171⁄8 125 GG0123RN 15 193⁄4 100 E2N3R c 12 179⁄16 0 16 22 ⁄64 07 ⁄4 F6N3R b 0 45 381⁄8 J6N3R b 126 4063⁄64 263⁄4 1123⁄32 353⁄4 600 LD6N3R b 137 4563⁄64 263⁄4 1123⁄32 403⁄4 800 LMD3R b 210 619⁄64 1200 MND63 b 210 619⁄64 0 100 0 d d c 0 1 21 7 ⁄8 3 4 ⁄16 14 ⁄8 45⁄16 141⁄8 5 0 0 09 05 0 0 73⁄8 1 E F G H — — — — 071⁄2 115⁄16 051⁄4 — 1 4 ⁄2 1 ⁄8 0 11 3 ⁄16 — 41⁄2 11⁄8 0 0 0 311⁄16 — 11⁄4 041⁄2 — 51⁄4 1 0 3 — 05 ⁄4 1 03 — 513⁄16 131⁄2 513⁄16 181⁄4 21⁄8 241⁄2 11⁄8 181⁄4 21⁄8 241⁄2 11⁄8 263⁄4 1123⁄32 5717⁄32 181⁄4 21⁄8 245⁄8 11⁄16 263⁄4 1123⁄32 21⁄8 245⁄8 11⁄16 71⁄4 1 169⁄16 06 1 51⁄4 1239⁄64 05 ⁄4 17 ⁄8 1 141⁄16 073⁄4 3 0 1 339⁄32 08 4 LMXD6, LMD6, HLMXD6, HLMD6 1 MD6, MXD6, SMD6, f HMD6, HMXD6, SHMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6,SCND6 2–3 2–3 2–3 For inches / millimeters conversion, see Application Data section. Note: All above enclosures are suitable for use as service enterance equipment. aDoes not include circuit breaker. Order circuit breaker separately. 6-10 e 0 0 5717⁄32 181⁄4 bNeutral not included. Order as separate item from table on next page. included in enclosure. dWill not accept breaker with shunt trip. eWill not accept 2 pole GFP or breaker with shunt trip. fIncludes 100% rated breakers. cNeutral Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Product Category MCCB Enclosed Circuit Breakers Enclosures — Type 3R Selection / Dimension Dimensions Figure 4 Figure Breaker Number Frame QJ2, QJH2, 6 QJ2-H Figure 5 Number of Poles 2 3 Maximum Current Catalog Rating Number WB2225 WB3225 225 225 Weight Lb./Ship. Dimensions (inches) Package A B C D 17 17 27 27 5 55⁄8 0711⁄16 103⁄8 21⁄4 21⁄4 E F G H J K L M 2 2 27⁄8 27⁄8 20 20 41⁄8 41⁄8 35⁄8 51⁄8 23⁄4 23⁄4 23⁄4 23⁄4 — 41⁄2 Neutrals d Enclosure Catalog Number Neutral Cable Capacity and Wire Range 6 Neutral Catalog Number (1 PC.) #14-2/0 Cu/Al, (1 pc.) #1-300 kcmil Cu/Al Grd. Lug (1 pc.) #12 - #4 Cu/Al (3 pcs.)#12 - #10 Cu/Al WB2225 N225QJ WB3225 (1 pc.) #4 - 2/0 Cu/Al (1 pc.) #1 - 300 kcmil Cu/Al Gnd. Lug (1pc.) #14 - #4 & (3 pcs.) #14 - #10 Cu or (1 pc.) #12 - #4 & (3 pcs.) #12 - #10 Al W53045 b E2N3R CED6N3R c (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al F6N3R N250 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al d J6N3R W60992 (1 pc.) #1/0–750 kcmil Cu/Al or (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al d LD6N3R W60993 d W63623 LMD3R MND63 ENCLOSED CIRCUIT BREAKERS N125GG GG0123RN (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al (4 pcs.) 250 kcmil–500 kcmil Cu/Al e Grd. Lug (1 pc.) #6–300 kcmil Cu/Al Hubs — see page 6-14. For inches / millimeters conversion, see Application Data section. aNeutral not included. Order as separate item from table on next page. Product Category MCCB bNeutral included in enclosure. CED enclosure for all ED-frame 110-125 ampere units. d200% neutrals are also available. See listing on page 6-9. c Use eFor applications requiring 600MCM neutral conductors (3) in, (3) out (#4-600 kcmil Cu/Al) use neutral catalog number W41123. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 6-11 • Revised • 06/06/14 Enclosed Circuit Breakers Enclosures — Types 4, 4X, 7, and 9 Selection / Dimensions Dimensions Figure 1A Figure 1 Figure 1B Types 4 and 4X Breaker Frame 6 i ENCLOSED CIRCUIT BREAKERS Figure 2 NGG ED2, ED4, ED6, j HED4 ED2, ED4, ED6, HED4 ED2, ED4, ED6, HED4 FXD6, FD6, j HFD6, FXD6, FD6 hj JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6,HHJXD6, SJD6, SHJD6, LXD6, LD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6 See Figure Number Drawing of Poles Maximum Current Rating Catalog Number a 1A 2–3 125 GG0124XN 1A 3 125 ED6SS4g 1B 1B 3 3 125 125 ED6S4 ED6S4316 1A 2–3 250 FD6SS4g 1A 2–3 600 LD6SS4 ng Weight Lb./Ship Package Dimensions (inches) A B C D E F G 19¼ 17¼ 09½ — 035⁄8 35⁄8 18¾ 44 20 16 06 075⁄32 09¾ 3 — 19 19 16.27 16.27 17.46 17.46 — — 09.17 09.17 — — 5.33 5.33 6.12 6.12 106 36 24 08 095⁄32 11¾ 3 — 145 42 30 10 115⁄32 13¾ 3 — Neutrals Neutral Catalog Number c W53045 ED6SS4 Neutral Cable Capacity and Wire Range (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al df N250 FD6SS4 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al df W60993 LD6SS4 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al Figure 2 Enclosure Catalog Numberb Types 7 and 9 e Number of Poles Breaker Frame Maximum Current Catalog Rating Number d f ED2, ED4, ED6, 2–3 HED4 015–60 070–100 EA n EB n CED6 2–3 100 N/A FXD6, FD6, HFD6, HFXD6, CFD6 2–3 250 JXD2, JXD6, JD6, SJD6, 2–3 HJD6, HJXD6, HHJD6, HHJXD6, SHJD6 LXD6, LD6, SLD6, HLD6, HLXD6, HHLD6, HHLXD6, SHLD6 2–3 Dimensions (inches) Weight Outside Lb./Ship. Mounting Inside Package A B C D E F G H K 027 032 0 1 5 ⁄2 0 6 0 13 ⁄8 515⁄16 103⁄4 0 1 18 6 ⁄2 16 EC2 n 085 101⁄4 225⁄8 113⁄4 200–350 300–400 EC4 n EE n 85 0 93 0 101⁄4 081⁄2 600 ED6 n 190 117⁄8 For inches / millimeters conversion, see Application Data selection. Note: Above enclosures are suitable for use as service entrance equipment. ■ Built to order. Allow 2–3 weeks for delivery. a Does not include circuit breaker. Order circuit breaker separately. 6-12 Conduit Size Std. Max 5 ⁄16 59⁄16 0 7 9 ⁄16 141⁄4 0 7 9 ⁄8 193⁄8 5 6 ⁄8 611⁄16 1 ⁄8 1 ⁄4 2 2 11⁄4 2 20 61⁄2 153⁄8 237⁄8 81⁄4 23⁄4 21⁄2 2 225⁄8 113⁄4 271⁄8 103⁄4 20 241⁄8 61⁄2 73⁄4 153⁄8 137⁄8 237⁄8 271⁄4 81⁄4 99⁄16 23⁄4 21⁄2 4 3 3 4 403⁄4 133⁄8 377⁄8 77⁄8 181⁄8 425⁄8 97⁄8 35⁄8 4 4 1 shipped with handle and breaker hardware packaged within enclosure. included. d Neutral not included. Order as separate item. e Breather and drain option is by SPECIAL ORDER only — add $70.00 to list price. 7 b Enclosures f For c Neutral gSuitable Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Knockouts 5 1 400A max. 4/4x applications which require a 200% Neutral. See listing on page 6-9. for use as Service Entrance device. hIncludes 100% rated breakers. iNon-metallic enclosure. j304 Stainless Steel enclosures. 316 Stainless Steel enclosures. Product Category MCCB Enclosed Circuit Breakers Enclosures — Types 5, 12 and 12K Selection / Dimensions Types 5, 12 and 12K Number of Poles Maximum Current Catalog Rating Number Figure Number Breaker Frame 2 ED2, ED4, ED6, HED4 2–3 0100 E2N12 1 CED6, ED2, ED4, ED6 2–3 0125 CED6N12 FXD6, FD6, FXD6, FD6, HFD6, CFD6 2–3 0250 F6N12 a c JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 2–3 0400 LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6, CJD6, CLD6, SCJD6, SCLD6 2–3 4 LMXD6, LMD6, HLMXD6, HLMD6 4 h MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6, SCND6 2 3 3 Dimensions (inches) A B C D E F 012 18 ⁄8 08 ⁄32 07 ⁄16 18 06 ⁄16 1 016 23 ⁄8 08 ⁄32 07 ⁄16 22 ⁄4 06 ⁄16 1 040 3819⁄32 1429⁄64 081⁄8 34 13 23 J6N12 104 411⁄2 215⁄8 117⁄8 375⁄32 203⁄8 5 0600 LD6N12 n 104 461⁄2 215⁄8 117⁄8 425⁄32 203⁄8 5 2–3 0800 LMD12 n 220 60 2–3 1200 MND612 c n 220 60 Weight Lb./Ship. Package ad ad n 5 3 11 11 1 1 373⁄8 10 373⁄8 10 3 1 1 ⁄2 ⁄2 ⁄32 ⁄8 ⁄8 ⁄8 3 2 005⁄8 3 2 3 Dimensions 6 ENCLOSED CIRCUIT BREAKERS Figure 2 Figure 3 Figure 1 Neutrals Neutral Catalog Number W53045 d Enclosure Catalog Number E2N12 CED6N12 e Neutral Cable Capacity and Wire Range (1 pc.) #14–2 Cu/Al (1 pc.) #14–2 Cu/Al F6N12 N250 cf (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al J6N12 W60992 cf (1 pc.) #1/0–750 kcmil Cu/Al or (2 pc.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al L6N12 W60993 cf W63623 c LMD612 MND612 (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al For inches/millimeters conversion, see Application Data section. n Built to order. Allow 2–3 weeks for delivery. Note: All above enclosures are suitable for use as service entrance devices. Product Category MCCB a Catalog Number is for Type 12. If Type 12K with knockouts is required, add suffix “K” to catalog number. b Does not include circuit breaker. Order circuit breaker separately. c Neutral not included. Order as separate item. d Neutral included in enclosure. Figure 4 e Use CED enclosure for all ED-frame 110–125 ampere units. neutrals are also available. See listing on page 6-9. g For 600 MCM neutral cable (3) in, (3) out (#4-600 kcmil Cu/ Al) use catalog number W411239 h Includes 100% rated breakers. f 200% Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 6-13 Enclosed Circuit Breakers Enclosures — Knockout and Hub Data Dimensions Knockouts & Wire Bending Space Types 1, 12 and 12K Number of Knockouts Per Panel (Type 4, 4X, 12 have no KO’s) Type 3R Breaker Frame Conduit Range Per Knockout Outside Dimensions (inches) Top Bottom Side Back Bottom Side Back Maximum Hub Size (inches) Type 3R Maximum Cable Sizes Recommended (Cu/Al) for Type 1, 3R, 4, 4X, 12 & 12K Enclosures e f QP, QPH, HQP 15–125 1 ⁄2, 3⁄4, 1, 11⁄4, 11⁄2 4 4 4 4 3 1 1 2 71⁄8" high encl. #6 c BQ, BQH, HBP 70–100 3 ⁄4, 1, 11⁄4 1 1 2 2 8 1 3 2 d QPP, QPPH, HQPP 125–225 1 ⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — 4 1 1 21⁄2 250 kcmil QJ 11⁄2, 2, 21⁄2, 3 2 2 2 2 3 1 1 21⁄2 d NGG 3 ⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — — — — — ED2, ED4, ED6, HED4 7 ⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2 2 2 2 2 1 1 2 d — 2 1 d ⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2 a 2 a — — 2 — ⁄8, 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2 2 2 2 b 2 b — 1 FXD6, FD6, FXD6, FD6 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2, 3 HFD6, CFD6 CED6 7 7 1 1 2 2 1 1 1 1 — — 1 — — 4 — d b b JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil LXD6, LD6, HLXD6, HLD6, HHLD6, HHLXD6, SLD6, SHLD6 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil LMXD6, LMD6 HLMXD6, HMLD6 — — — — — — — — 4 (3) 600 kcmil 6 MD6, SMD6, HMD6 — — — — — — — — 4 ND6, SND6, HND6 ENCLOSED CIRCUIT BREAKERS (CFD6 only 300 kcmil) (3) 600 kcmil or (4) 500 kcmil Hubs (Type 3R) Breaker Frame Conduit Size (inches) Catalog Number QP, QPH, HQP, BQ, BQH, HBQ, NGG 03⁄4 1 11⁄4 11⁄2 2 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 QPP, QPPH, HQPP, QJ2, QJH2, QJ2-H 11⁄4 11⁄2 2 21⁄2 ECHS125 ECHS150 ECHS200 ECHS250 ED2, ED4, ED6, HED4, HED6, HHED6, CED6 03⁄4 1 11⁄4 11⁄2 2 ECHR075 ECHR100 ECHR125 ECHR150 ECHR200 FXD6, FD6, HFD6, HFXD6, CFD6, JXD2, JD6, JXD6, HJD6, HJXD6, LD6, LXD6, HLD6, HLXD6(A) 2 21⁄2 3 31⁄2 4 ECHV200 ECHV250 ECHV300 ECHV350 ECHV400 For inches / millimeters conversion, see Application Data section. a Type 12K only. b Type 12K enclosure has no knockouts this location. 6-14 c 171⁄8" high enclosure provides sufficient wire bending space for all available CB lugs. d Sufficient wire bending space is provided for all available mechanical type CB lugs. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Note: Enclosures for 250A max breakers have a hub provision on the rainshed. Enclosures for larger breakers (J, L, M & N frame) have blank top rainsheds. Drill or punch hole in the field to accommodate hub size desired. e The use of cables larger than those listed below may violate NEC & UL wire bending space requirements. use of compression type connectors will violate NEC and UL wire bending space requirements. f The Product Category MCCB