EDWARDS 5540MP-24Y6 Adaptatone Millennium Central Tone

advertisement
ELECTRONIC SIGNALS
Adaptatone® Millennium
Central Tone Generator
Synchronized System
Paging & Signaling
5540MP Series
FEATURES
> Voice paging
> 27 tone capability - No additional
tone modules needed
> Suitable for Division 2 Locations
> Centralized programmable tone
selection
> System-wide priority tone
selection
AGENCY APPROVALS
> NEMA Type 3R
> IP 44
> UL 464 and 1604 Listed
> UL Listed for indoor and outdoor
applications in Class I, Div. 2,
Groups A, B, C & D; Class II, Div.
2, Groups F & G; and Class III
hazardous locations
> cUL C22.2 No. 205
SPECIFICATIONS
> 24V DC battery backup terminals
provided
www.leedan.com
info@leedan.com
Toll-Free: 800-231-1414
The Edwards 5540MP Millennium Central Tone Generator, when
used with the 5542RPU Remote Paging Unit, is designed for applications where voice paging and other audio output are desired. The
paging/voice signal is inputed into the Remote Paging Unit via either an audio pair or the 5542MIC series microphone.
The Millennium Central Tone Generator produces the 27 standard
Adaptatone sounds. The tone generator assures a synchronous signaling sound from all remote speakers. Three tones may be programmed into the Tone Generator at any time. The tones may be
selected by setting miniature dip switches within the unit. The tones
operate on a pyramid-type priority system. The input from the Remote Page Unit has priority over all three tones. The three signals
may be activated from field-wired, normally open contacts or a
240VDC external voltage source such as an output from a PLC.
Normally open contacts can be obtained from the Cat. No. 5538-4 or
Cat. No. 5538-4R Adaptatone Signal Actuator.
Adaptatone Signaling Systems are designed for industrial applications calling for high decibel output, voice paging, and microprocessor reliability combined with simultaneous signal delivery over all
speakers included in the system. Typical applications include: emergency warning systems, plant evacuation alarms, security intrusion
sirens, process monitoring, shift start-and-dismissal horns, and
paging signals.
4-32
D-002
> Short Circuit protected
90 Fieldstone Court | Cheshire, CT 06410
Ph: 203.699.3300 | Fx: 203.699.3108
www.edwards-signals.com
© Copyright 2002 Edwards
ELECTRONIC SIGNALS
TECHNICAL INFORMATION
www.leedan.com info@leedan.com Toll-Free: 800-231-1414
8"
(203mm)
Mounting flange
4 holes (2 each side)
6"
(152mm)
2 1/2"
(64mm)
6"
(152mm)
1/2" (13mm)
conduit mounting
3 1/2"
(89mm)
Operating
Voltage
Input Card
Activation Voltage
Signal Off
Standby Current (Amps)
Signal On
Operating Current (Amps)
120V AC 50/60 Hz
240V AC 50/60 Hz
125V DC
250V DC
24V DC
0.10
0.10
0.10
0.10
0.32
0.20
0.21
Cat. No.
5540MP-24Y6*
4"
(102mm)
0.02
* Must be connected to 5542RPU to operate
Typical Adaptatone Paging System Configuration
Speaker/Amplifier
Cat. No. 5532MHV
Hazardous
Location
Speaker/Amplifier
Cat. Nos. 5545B
Speaker/Amplifier
Cat. No. 5532M
Local/System Signal
Cat. No. 5536M
3 Local Tones
Central Tone
Generator with paging
Cat. No. 5540MP
4 wires
5 wires
Reentrant
Speaker
Cat. No. 5547
Remote Amplifier
Cat. No. 5535
Remote Signal Actuator
Cat. No. 5538-4
for local inputs 2, 3, 4
*Local Power 3 wires
90 Fieldstone Court | Cheshire, CT 06410
Ph: 203.699.3300 | Fx: 203.699.3108
www.edwards-signals.com
4-33
© Copyright 2002 Edwards
D-002
Cone Speaker
Cat. No. 5551B
Cat. No. 5542RPU-M
1V peak to peak audio
source or telephone system
audio converted using
Bogen Telephone Access
Module or equivalent