Liebert GXT MT+

advertisement
Power Protection for
Business Critical Continuity
Liebert GXT-MT +
Trouble is Coming
Down The Line
And You Must Be
Prepared
Every operation in your business depends upon the instant,
around-the clock availability of computers, servers and other
electronic systems. If they aren’t working, neither is your
company.
Every piece of this equipment your company possesses is
subject to the whims of the electricity that powers it.
The first step in taking control of this situation is to understand
the threats to your system reliability — and exactly what you can
do about them.
The Liebert GXT-MT +
True Online Double Conversion UPS With Extended Runtime Capabilities
Liebert GXT-MT + features a comprehensive specification, satisfies safety criteria and
electromagnetic compatibility standards, and offers intelligent monitoring and network
management functions.
Liebert GXT-MT + satisfies your requirements for high reliability and high availability of the AC
power supply.
Liebert GXT-MT + is available in a compact Tower configuration making it easily deployed in an
office or a light industrial application.
Liebert GXT-MT + long run model (L) deploys adaptive battery architecture to maximise your
valuable rack space utilisation. Application specific battery configuration and placement ensures
optimal performance.
NOTE:-
Liebert GXT-MT + standard model is provided complete with internal battery.
Liebert GXTL-MT + (long back up model) application specific battery and cabinet available through your local Emerson
Network Power representative.
Applications
Small Size Data Center
Telecommunication, VoIP
Small Office Network
Data Warehouses
Medical Diagnostics
Process Automation Equipments
Features
0.8 o/p p.f with LCD Display Option
Extended Runtime Capabilities
Flexible (Site Specific) Battery Configuration
Compact Tower design.
Generator Compatible
Class B Electromagnetic interference (EMC)
compatible
Ultra wide input voltage range
High capacity Battery Charger for GXTL
High input power factor & low THDi
Liebert GXT - MT +
True Online
Double Conversion
Flexible Configuration
Extended Run Time ready
facilitated through a simple
process of building up
additional battery resources.
Multiple AC output
interfaces via IEC standard
sockets
Convenient maintenance
Fault type is clearly displayed
for fast troubleshooting.
LCD display provides maximum operational convenience when managing the UPS.
Intelligent Management functions
Stronger Battery charger on the GXT L model for quick recharge
Remote Monitoring is available through RS232, and optional via dry contacts and SNMP. The
monitoring option software supports TCP/IP with event log and analysis function.
Self-diagnosis and protection enable the auto shutdown of the client terminal or server under
abnormal mains supply or when battery is over discharged.
True On-Line
Double
Conversion
Technology:
When “Adequate” protection
is not enough
Technical Specifications
Model
1 kVA
2 kVA
3 kVA
Capacity
1kVA / 800W
2kVA / 1600W
3kVA / 2400W
Power Factor
0.8
0.8
0.8
Configuration
1 phase, L-N = PE
1 phase, L-N = PE
1 phase, L-N = PE
Nominal Voltage
220 / 230 / 240 Vac
220 / 230 / 240 Vac
220 / 230 / 240 Vac
Voltage Regulation
+ / - 3%
+ / - 3%
+ / - 3%
Voltage THD
<=3% - Linear Load <=6% - Non
Linear load
<=4% - Linear Load <=7% - Non
Linear load
<=4% - Linear Load <=7% - Non
Linear load
Frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Frequency Regulation - Free Run
(Unsynchronised with bypass)
+ / - 0.5 Hz
+ / - 0.5 Hz
+ / - 0.5 Hz
Frequency Regulation (Synchronised
with bypass)
47.5 to 52.5 HZ / 57.5 to 62.5 HZ
47.5 to 52.5 HZ / 57.5 to 62.5 HZ
47.5 to 52.5 HZ / 57.5 to 62.5 HZ
Slew Rate
1 Hz per second maximum
1 Hz per second maximum
1 Hz per second maximum
Creast Factor
3:1 max.
3:1 max.
3:1 max.
Transient response at 100% step load
+ / - 6% On line mode;
+ / - 6% On line mode;
+ / - 6% On line mode;
Recovery time
<150ms
<150ms
<150ms
Over load capacity
110% - 130% - 12 sec; >130 - 1.5 sec 110% - 130% - 12 sec; >130 - 1.5 sec 110% - 130% - 12 sec; >130 - 1.5 sec
AC - AC Efficiency
88% R-Load, 87% RCD - Load
88% R-Load, 87% RCD - Load
88% R-Load, 87% RCD - Load
Transfer time - Mains to battery
0 millisec
0 millisec
0 millisec
Transfer time - Inverter to bypass Synchronisation mode
4 msec
4 msec
4 msec
Configuration
1 phase, L-N + PE
1 phase, L-N + PE
1 phase, L-N + PE
Nominal Voltage
230 Vac
230 Vac
230 Vac
Voltage range
160V to 300V at 100% Load, At
60% Load 110V to 300 Vac
160V to 300V at 100% Load, At
60% Load 110V to 300 Vac
160V to 300V at 100% Load, At
60% Load 110V to 300 Vac
Frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Frequency range - Hz
40 - 70 Hz
40 - 70 Hz
40 - 70 Hz
Power Factor
>=0.95
>=0.95
>=0.95
Current Distortion (I-THD)
12% linear, 13% nonlinear
12% linear, 13% nonlinear
12% linear, 13% nonlinear
220 / 230 / 240 Vac
220 / 230 / 240 Vac
220 / 230 / 240 Vac
198V - 242V For 220V
198V - 242V For 220V
198V - 242V For 220V
207V - 253V For 230V
207V - 253V For 230V
207V - 253V For 230V
216V - 264V For 240V
216V - 264V For 240V
216V - 264V For 240V
Frequency
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
Frequency Range
47.5 to 52.5 Hz / 57.5 to 62.5 Hz
47.5 to 52.5 Hz / 57.5 to 62.5 Hz
47.5 to 52.5 Hz / 57.5 to 62.5 Hz
OUTPUT PARAMETERS
INPUT PARAMETERS
BYPASS
Voltage
Technical Specifications
Model
1 kVA
2 kVA
3 kVA
Nominal Voltage - Float
41 Vdc
108 Vdc
82.1 Vdc
Maximum charging current - STD. / LB.
1A - STD and 4 / 8 A - LB
1A - STD and 4 / 8 A - LB
1A - STD and 4 / 8 A - LB
Better Connector
5 pin Wago 770-750
5 pin Wago 770-750
5 pin Wago 770-750
Type
SMF
SMF
SMF
No. of battery blocks
3
8
8
Battery Voltage
36 VDC
96 V
96V
Maximum Back up time at full load
STD. 7 minutes / 7 AH
STD. 6.5 minutes / 7 AH
STD. 5 minutes / 7 AH
Operating temperature
0 to 40 deg. centigrade
0 to 40 deg. centigrade
0 to 40 deg. centigrade
Storage temperature
-20 to 50 deg. centigrade
-20 to 50 deg. centigrade
-20 to 50 deg. centigrade
Relative Humidity
90% RH
90% RH
90% RH
<45db
<45db
<45db
Height X Width X Depth (MM)
220 X 145 X 388.5
318 X 190 X 387
318 X 190 X 387
Weight
13 kg. - STD., 7 kg. - LB
26 kg. - STD., 13 kg. - LB
28 kg. - STD., 13 kg. - LB
Ventilation
Forced - Air cooled
Forced - Air cooled
Forced - Air cooled
Cable Entry
Backside
Backside
Backside
Colour / Panel finish
RAL 7016 dark grey
RAL 7016 dark grey
RAL 7016 dark grey
Protection
IP20
IP20
IP20
Communication Port
RS232, USB
RS232, USB
RS232, USB
EPO
Yes
Yes
Yes
MONITORING SOFTWARE
SNMP, dry contact card,
UPSilon 2000
SNMP, dry contact card,
UPSilon 2000
SNMP, dry contact card,
UPSilon 2000
EMI
EN 62040-2: 2006
EN 62040-2: 2006
EN 62040-2: 2006
SAFETY
EN 62040-1-1: 2003
EN 62040-1-1: 2003
EN 62040-1-1: 2003
PERFORMANCE (technical feature)
IEC / EN 62040 - 3
IEC / EN 62040 - 3
IEC / EN 62040 - 3
Transportation
IEC 600068-2-32 - DROP TEST
IEC 600068-2-32 - DROP TEST
IEC 600068-2-32 - DROP TEST
IEC 60068-2-64 - VIBRATION TEST
IEC 60068-2-64 - VIBRATION TEST
IEC 60068-2-64 - VIBRATION TEST
IEC 60068-2-27 - SHOCK TEST
IEC 60068-2-27 - SHOCK TEST
IEC 60068-2-27 - SHOCK TEST
EN 50272 - VOLUME / AIR FLOW /
DEGASSING STANDARD
EN 50272 - VOLUME / AIR FLOW /
DEGASSING STANDARD
EN 50272 - VOLUME / AIR FLOW /
DEGASSING STANDARD
CE MARK
CE MARK
CE MARK
BATTERY CHARGER
BATTERY PARAMETERS
ENVIRONMENTAL PARAMETERS
Altitude
Noise level
MECHANICAL PARAMETERS
STANDARDS
Miscellaneous
Country Office
Emerson Network Power (India) Private Ltd.
Plot No. C-20, Road No. 19, Wagle Estate,
Thane (w), Maharashtra - 400 604. India.
Tel.: 91-22-67208000
Fax: 91-22-25828358
Toll Free No 18002096070
Email: marketing.india@emerson.com
Voice of Customers UPS Awards 2004-05 for Product Line
& Customer Service Awards in IT, Telecom,
Large Enterprise & Hospitals and
Customer Service Leadership Award in BFSI
2007
R
Best IT Hardware Company
Maharashtra IT Award 2006-07
www.emersonnetworkpower.co.in
Emerson Network Power.
TM
The global leader in enabling Business-Critical Continuit y .
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
While every precaution has been taken to ensure accuracy and completeness in this brochure, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this
information or for any errors or omissions.
For disposal of Batteries Please visit the below link:
http://www.cpcb.nic.in/divisionsofheadoffice/hwmd/lead.pdf
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. © 2009 Emerson Electric Co.
Download