SIDER appli_256_a sider_102_a_1_cat sider_089_a_1_cat Load break switches for power distribution Load break switches with visible breaking from 125 to 1600 A 4 ‹ Function SIDER are manually operated 3 or 4 pole load break switches. They make and break under load conditions and provide safety isolation for any low voltage electric circuit. 2 ‹ General characteristics • Fully visible breaking. • Visible double breaking. ‹ Conformity to standards ‹ Approvals and certifications (1) • • • • • • PSA E03.15.605.G • RENAULT EB03.15.613 • UKR (Ukraine) • GOST (Russia) IEC 60947-3 EN 60947-3 VDE 0660-107 (1992) NBN EN 60947-3 BS EN 60947-3 (1) Product reference on request. 56 sider_091_b_1_x_cat 1 3 Functional diagram (for further details see the installation instructions supplied with every device). 1. External front operation 2. External side operation 3. 2x2 configurable U type ACs, for pre-break and signalling or TEST. 4. Terminal shrouds General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER ‹ References sider_102_a_2_cat Front operation Rating (A) ND 125 A ND 200 A ND 250 A ND 315 A ND 400 A ND 500 A 630 A 800 A 1 250 A 1 600 A Switch body Direct operation Switch body External operation 3P 2915 3012 2921 3012 4P 2915 4012 2921 4012 3P 2915 3021 2921 3020 4P 2915 4021 2921 4020 3P 2915 3025 2921 3025 4P 2915 4025 2921 4025 3P 2915 3031 2921 3031 No. of poles 4P 2915 4031 2921 4031 3P 2915 3041 2921 3041 4P 2915 4041 2921 4041 3P 2915 3051 2921 3051 4P 2915 4051 2921 4051 3P 2900 3063 2900 3063 4P 2900 4063 2900 4063 3P 2900 3080 2900 3080 4P 2900 4080 2900 4080 3P 2900 3120 2900 3120 4P 2900 4120 2900 4120 3P 2900 3160 2900 3160 4P 2900 4160 2900 4160 Shaft for external handle Auxiliary contacts Black 3629 7901(1) S2 type Black IP55 1421 2111(1) Black IP65 1423 2111 Red IP65 1424 2111 200 mm 1400 1020 320 mm 1400 1032(1) 500 mm 1400 1050 1st contact NO/NC 3999 0021(2)(3) 2 contacts NO/NC 3999 0022(2)(3) 1 contact NC 3999 0701(4)(5) 1 contact NO 3999 0702(4)(5) Black 2799 7012(1) Red 2799 7013 S4 type Black IP65 1443 3111(1) Red/Yellow IP65 1444 3111 200 mm 1401 1520 320 mm 1401 1532(1) 400 mm 1401 1540 1st inverter NO/NC 2799 0001(2) 2nd contact NO/NC 2799 0002(2) Direct handle External handle (1) Standard. (2) Auxiliary signal contact - Type S. (3) For direct operation. (4) For external operation. (5) Auxiliary signal contact - Type U. SOCOMEC General Catalogue 2011-2012 57 ‹ SIDER - References (continued) sider_089_a_1_cat Side operation Rating (A) ND 125 A ND 200 A ND 250 A ND 315 A ND 400 A ND 500 A 630 A 800 A 1 250 A 1 600 A No. of poles Switch body Direct operation Switch body External right side operation 3P 2915 3012 2921 3012 4P 2915 4012 2921 4012 3P 2915 3021 2921 3020 4P 2915 4021 2921 4020 3P 2915 3025 2921 3025 4P 2915 4025 2921 4025 3P 2915 3031 2921 3031 4P 2915 4031 2921 4031 3P 2915 3041 2921 3041 4P 2915 4041 2921 4041 3P 2915 3051 2921 3051 4P 2915 4051 2921 4051 3P 2905 3063 2905 3063 4P 2905 4063 2905 4063 3P 2905 3080 2905 3080 4P 2905 4080 2905 4080 3P 2905 3120 2905 3120 4P 2905 4120 2905 4120 3P 2905 3160 2905 3160 4P 2905 4160 2905 4160 Direct handle External handle Black 3629 7901(1) S2 type Black IP55 1425 2111(1) Black IP65 1427 2111 Red/Yellow IP65 1428 2111 Black 2799 7052(1) Conversion kit 2799 7070(5) Red 2799 7053 Conversion kit 2799 7070(5) S3 type Black IP65 1437 3111(1) Red/Yellow IP65 1438 3111 Shaft for external handle Auxiliary contacts 200 mm 1400 1020(1) 1st contact NO/NC 3999 0021(2)(3) 2 contacts NO/NC 3999 0022(2)(3) 1 contact NC 3999 0701(4)(6) 1 contact NO 3999 0702(4)(6) 200 mm 1401 1520(1) 1st contact NO/NC 2799 0011(2) 2nd contact NO/NC 2799 0012(2) (1) Standard. (2) Auxiliary signal contact - Type S. (3) For direct operation. (4) For external operation. (5) Conversion kit necessary for any direct operation. (6) Auxiliary signal contact - Type U. 58 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER ‹ Accessories Direct operation handle For front operation Rating (A) ND 125 … ND 500 630 … 1 600 630 … 1 600 Handle colour Black Black Red Reference 3629 7901 2799 7012(1) 2799 7013 Handle colour Black Black Red Reference 3629 7901 2799 7052 2799 7053 For side operation Rating (A) ND 125 … ND 500 630 … 1 600 630 … 1 600 acces_153_a_1_cat acces_148_a_1_cat (1) Standard. Direct side escutcheon for operation Rating (A) External IP 630 … 1 600 IP54 Reference 2799 7070 External operation handle S2 type handle acces_166_a_2_cat acces_150_a_3_cat For front operation Handle Rating (A) colour ND 125 … ND 500 Black ND 125 ND 500 Black ND 125 … ND 500 Red 630 … 1 600 Black 630 … 1 600 Red Handle S2 type S2 type S2 type S4 type S4 type External IP (1) IP55 IP65 IP65 IP65 IP65 Reference 1421 2111(2) 1423 2111 1424 2111 1443 3111(2) 1444 3111 (1) IP: Degree of protection according to standard IEC 60529. (2) Standard. For right side operation acces_152_a_1_cat S3 type handle S4 type handle Rating (A) ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 630 … 1 600 Handle S2 type S2 type S3 type S3 type Handle colour Black Red Black Red External IP (1) IP55 IP65 IP65 IP65 Reference 1425 2111 1428 2111 1437 3111 1438 3111 (1) IP: Degree of protection according to standard IEC 60529. Shaft guide for external operation acces_260_a_2_cat Use To guide the shaft extension into the external handle. This accessory enables handle to engage extension shaft with a misalignment of up to 15 mm. Required for a shaft length over 320 mm. Description Shaft guide Reference 1429 0000 S type handle adapter acces_187_a_1_cat Use Enables S type handles to be fitted in place of existing older style Socomec handles. Adapter can also be utilised as a spacer to increase the distance between the panel door and the handle lever. SOCOMEC General Catalogue 2011-2012 Handle colour Black To be ordered in multiples of 10 Dimensions Adds 12 mm to the depth. External IP (1) IP65 Reference 1493 0000 (1) IP: Degree of protection according to standard IEC 60529. 59 ‹ SIDER - Accessories (continued) Alternative S type handle cover colors Use For single lever handles type S1, S2, S3 and double lever handle, type S4. Other colours: consult us. To be ordered in multiples of 50 50 50 50 acces_198_a_1_cat Handle colour Light grey Dark grey Light grey Dark grey Use Standard lengths: - 80 mm, - 200 mm, - 320 mm, - 400 mm, - 500 mm. Reference 1401 0001 1401 0011 1401 0031 1401 0041 Other lengths: consult us. For front operation Dimension Rating (A) X (mm) ND 125 … ND 500 95 … 230 ND 125 … ND 500 95 … 350 ND 125 … ND 500 95 … 530 630 … 1 600 295 … 555 630 … 1 600 295 … 675 630 … 1 600 295 … 755 acces_203_a_1_x_cat acces_202_a_1_x_cat acces_144_b_1_cat acces_143_b_1_cat Shaft for external handle Handle Type S1, S2 Type S1, S2 S4 type S4 type Shaft length (mm) 200 mm 320 mm 500 mm 200 mm 320 mm 400 mm Type 10 x 10 10 x 10 10 x 10 15 x 12 15 x 12 15 x 12 Reference 1400 1020 1400 1032 1400 1050 1401 1520 1401 1532 1401 1540 Shaft length (mm) 80 mm 200 mm 200 mm Type 10 x 10 10 x 10 15 x 12 Reference included 1400 1020 1401 1520 For side operation X Y Rating (A) ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 Dimension Y (mm) 20 … 110 20 … 230 98 … 258 Auxiliary contacts for pre-break and signalling - Front operation acces_047_a_2_cat NO/NC contact Rating (A) ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 630 … 1 600 acces_056_a_1_cat Characteristics NO/NC AC: IP2. Electrical characteristics 30 000 operations. 60 Reference 3999 0021(1) 3999 0022(1) 2799 0001 2799 0002 Position AC 1 to 4 Reference 3999 0701(1) Position AC 1 to 4 Reference 3999 0702(1) Position AC 1 Reference 2799 0005 Low level NO/NC auxiliary contacts Rating (A) Position AC 630 … 1 600 1 Reference 2699 0101 (1) For direct operation. Use Pre-break and signalling of positions 0 and I: - 1 to 2 NO/NC auxiliary contacts, - 1 to 4 NO or NC auxiliary contacts. - 1 to 4 NO+NC auxiliary contacts. Connection to the control circuit By 6.35 mm fast-on terminal. Position AC 1st 2 1st 2nd NC contact Rating (A) ND 125 … ND 500 (1) For direct operation. NO contact Rating (A) ND 125 … ND 500 (1) For direct operation. NO+NC contact Rating (A) 630 … 1 600 Characteristics Rating (A) Contact type Current nominal (A) ND 125 … ND 500 ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 630 … 1 600 inverter NO/NC NC NO inverter NO/NC NO + NC 16 10 10 16 15 Operating current Ie (A) 250 VAC 400 VAC 24 VDC AC-13 AC-13 DC-13 6 6 12 10 3 4 4 8 6 12 5 5 14 15 48 VDC DC-13 2 3 3 6 12 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER acces_056_a_1_cat acces_047_a_2_cat Auxiliary contacts for pre-break and signalling - Right side operation Use Pre-break and signalling of positions 0 and I: - 1 to 2 NO/NC auxiliary contacts, - 1 to 4 NO or NC auxiliary contacts. NO/NC contact Rating (A) ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 630 … 1 600 Position AC 1st 2 1st 2nd Reference 3999 0021 3999 0022 2799 0011 2799 0012 NC contact Rating (A) ND 125 … ND 500 Position AC 1 to 4 Reference 3999 0701 NO contact Rating (A) ND 125 … ND 500 Position AC 1 to 4 Reference 3999 0702 Low level NO/NC auxiliary contacts Rating (A) Position AC 630 … 1 600 1 Reference 2799 0111 Characteristics Connection to the control circuit By 6.35 mm fast-on terminal. Characteristics NO/NC AC: IP2. Electrical characteristics 30 000 operations. Rating (A) Contact type Current nominal (A) ND 125 … ND 500 ND 125 … ND 500 ND 125 … ND 500 630 … 1 600 inverter NO/NC NC NO inverter NO/NC 16 10 10 16 Operating current Ie (A) 250 VAC 400 VAC 24 VDC 48 VDC AC-13 AC-13 DC-13 DC-13 6 6 12 3 4 4 8 12 5 5 14 2 3 3 6 acces_051_a_2_cat S type auxiliary contacts for signalisation - Front and right side operation Use Position 0 and I signalling 1 to 4 NO+NC auxiliary contacts. Electrical principle The NO+NC S-type auxiliary contacts can be configured as 2 NO or 2 NC. Connection to the control circuit By terminals with max. section 10 mm2. Electrical characteristics 30 000 operations. NO+NC contact Rating (A) ND 125 … ND 500 ND 125 … ND 500 ND 125 … ND 500 ND 125 … ND 500 Position AC 1 2 3 4 Reference 3999 0041 3999 0042 3999 0043 3999 0044 Operating current Ie (A) 250 VAC 400 VAC AC-13 AC-13 10 Characteristics Rating (A) Contact type Current nominal (A) ND 125 … ND 500 NO + NC 20 8 Terminal shrouds acces_093_a_1_cat Use Top or bottom protection against direct contact with terminals or connection parts. SOCOMEC General Catalogue 2011-2012 Rating (A) ND 125 … ND 200 ND 125 … ND 200 ND 250 … ND 500 ND 250 … ND 500 No. of poles 3P 4P 3P 4P Advantage Perforations allowing remote thermographic inspection without removal. Position top or bottom top or bottom top or bottom top or bottom Reference 3998 3016(1) 3998 4016(2) 3998 3025(1) 3998 4025(2) (1) Reference composed of 3 pieces. (2) Reference composed of 4 pieces. 61 ‹ SIDER - Accessories (continued) Terminal screens Use Top or bottom protection against direct contact with terminals or connection parts. acces_058_a_1_cat Rating (A) 630 … 800 630 … 800 1 250 … 1 600 1 250 … 1 600 No. of poles 3P 4P 3P 4P Position top / bottom top / bottom top / bottom top / bottom Reference 2998 3080 2998 4080 2998 3120 2998 4120 Cage terminals Use Connection of bare copper cables onto the terminals (without lugs). acces_053_a_1_cat Connections Section flexible cable (mm2) Section rigid cable (mm2) Width flexible bar (mm) Stripped over (mm) ND 125 ND 200 … ND 250 ND 315 … ND 400 ND 500 … 630 16 … 95 16 … 185 50 … 240 70 … 300 16 … 95 16 … 185 50 … 300 70 … 300 13 18 20 24 22 27 34 34 Dimensions X1 R øX A1 acces_092_a_1_x_cat Z acces_091_a_1_x_cat Rating (A) C A Rating (A) A A1 C R ØX X1 Z ND 125 ND 200 … ND 250 ND 315 … ND 400 ND 500 … 630 47.5 62 71.5 76.5 22.5 31.5 32 37 25 31.5 38 38 20 25 32 40 8.5 10.5 10.5 12.5 M12 M16 M20 M20 10 14 15 15 Rating (A) ND 125 ND 125 ND 200 … ND 250 ND 200 … ND 250 ND 315 … ND 400 ND 315 … ND 400 ND 500 … 630 ND 500 … 630 No. of poles 3P 4P 3P 4P 3P 4P 3P 4P Reference 5400 3016 5400 4016 5400 3025 5400 4025 5400 3040 5400 4040 5400 3063 5400 4063 Inter phase barrier acces_036_a_1_cat Use Safety isolation between the terminals, essential for use at 690 VAC or in a polluted or dusty atmosphere. 62 Rating (A) 630 … 1 600 630 … 1 600 No. of poles 3P 4P Reference 2998 0003 2998 0004 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER Handle key interlocking accessories Fig. 1 acces_084_a_1_x_cat acces_042_a_1_x_cat Use Locking in position 0 of front or side operation handle: - using RONIS EL11AP lock in direct front or right-side operation (Fig. 1), - using RONIS EL11AP lock in direct front operation (Fig. 2), Fig.2 - using RONIS EL11AP or CASTELL type K-type lock in external front operation (Fig. 3), - using RONIS EL11AP lock in external right-side operation, - using CASTELL FS-type in external front operation (Fig. 4). Locking using RONIS EL11AP lock (not supplied) Rating (A) Operation Figure ND 125 … ND 500 Front direct 1 630 … 1 600 Front direct 2 ND 125 … 1 600 External front 3 ND 125 … ND 500 Direct right side 1 ND 125 … 1 600 External right side 3 Reference 3629 7913(1) 2799 7007(2) 1499 7701 3629 7913(1) 1499 7701 Fig. 3 acces_157_a_1_x_cat acces_158_a_1_x_cat (1) Handle included. (2) Factory mounting only. Fig.4 Locking using type K CASTELL lock (not supplied) Rating (A) Operation Figure ND 125 … ND 500 external front 3 Reference 1499 7702 Locking using type FS CASTELL lock (not supplied) Rating (A) Operation Figure ND 125 ND 500 external front 4 Reference 1499 7703 Other specific accessories bd_03_04_01 • Mechanical coupling device for making switches with "n" poles of the same or different ratings. • Mechanical interlocking device. • Mechanical plates and escutcheon for standard systems. SOCOMEC General Catalogue 2011-2012 63 ‹ SIDER - Characteristics according to IEC 60947-3 ND 125 to ND 500 A Thermal current Ith (40°C) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kV) ND 125 A ND 200 A ND 250 A ND 315 A ND 400 A ND 500 A 800 8 800 8 800 8 800 8 800 8 800 8 Rated operational currents Ie (A) Rated voltage Load duty category 400 VAC AC-21 A / AC-21 B 400 VAC AC-22 A / AC-22 B 400 VAC AC-23 A / AC-23 B 500 VAC AC-20 A / AC-20 B 500 VAC AC-21 A / AC-21 B 500 VAC AC-22 A / AC-22 B 500 VAC AC-23 A / AC-23 B AC-20 A / AC-20 B 690 VAC(2) 690 VAC(2) AC-21 A / AC-21 B AC-22 A / AC-22 B 690 VAC(2) 690 VAC(2) AC-23 A / AC-23 B 220 VDC DC-20 A / DC-20 B 220 VDC DC-21 A / DC-21 B 220 VDC DC-22 A / DC-22 B 220 VDC DC-23 A / DC-23 B 440 VDC DC-20 A / DC-20 B 440 VDC DC-21 A / DC-21 B 440 VDC DC-22 A / DC-22 B 440 VDC DC-23 A / DC-23 B 500 VDC DC-20 A / DC-20 B 500 VDC DC-21 A / DC-21 B 500 VDC DC-22 A / DC-22 B 500 VDC DC-23 A / DC-23 B A/B(1) 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125 125/125(3) 125/125(3) 125/125(3) 125/125 125/125(3) 125/125(3) 125/125(3) A/B(1) 200/200 200/200 200/200 200/200 160/160 160/160 160/160 200/200 160/160 160/160 160/160 200/200 160/160 160/160 125/125 200/200 160/160(3) 160/160(3) 125/125(3) 200/200 160/160(3) 160/160(3) 125/125(3) A/B(1) 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 250/250 200/200 250/250 250/250(3) 250/250(3) 200/200(3) 250/250 250/250(3) 250/250(3) 200/200(3) A/B(1) 315/315 315/315 315/315 315/315 250/250 250/250 250/250 315/315 315/315 315/315 250/250 315/315 250/250 250/250 200/200 315/315 250/250(3) 250/250(3) 200/200(3) 315/315 250/250(3) 250/250(3) 200/200(3) A/B(1) 400/400 400/400 400/400 400/400 315/315 315/315 315/315 400/400 400/400 400/400 315/315 A/B(1) 500/500 500/500 500/500 500/500 315/315 315/315 315/315 500/500 500/500 500/500 315/315 400/400 315/315(3) 315/315(3) 200/315(3) 500/500 315/315(3) 315/315(3) 200/315(3) Operational power in AC-23 (kW) At 400 VAC without pre-break in AC-23 (kW)(1)(4) At 500 VAC without pre-break in AC-23 (kW)(1)(4) At 690 VAC without pre-break in AC-23 (kW)(1)(4) 63/63 85/85 110/110 110/110 110/110 150/150 140/140 160/160 220/220 160/160 160/160 220/220 220/220 220/220 295/295 295/295 220/220 295/295 Reactive power (kvar) At 400 VAC (kvar)(4) 55 90 115 145 185 230 Fuse protected short-circuit withstand (kA rms prospective) Prospective short-circuit (kA rms)(5) Associated fuse rating (A)(5) 100 125 35 200 100 250 60 315 50 400 30 500 Short-circuit capacity Rated short-time withstand current 0.3 s. ICW (kA eff.) Rated peak withstand current (kA peak)(5) 15 20 15 20 17 32.5 17 32.5 17 40 17 40 Connection Min. connection wire range Minimum Cu busbar section (mm2) Maximum Cu cable section (mm2) Maximum Cu busbar width (mm) Tightening torque min (Nm) 120 20 9 120 20 9 240 32 20 240 32 20 2 x 150 45 20 2 x 150 45 20 Mechanical characteristics Durability (number of operating cycles)(6) Operating effort (Nm) Weight of a 3 pole device (kg) Weight of a 4 pole device (kg) 10 000 10 1.8 2.3 10 000 10 1.8 2.3 10 000 12 3.2 4.5 10 000 12 3.2 4.5 10 000 15 4.8 6.1 10 000 15 4.8 6.1 (1) Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 pole in series by polarity. (4) The power value is given for information only, the current values vary from one manufacturer to another. (5) For a rated operational voltage Ue = 400 VAC. (6) Increased endurances: please consult us. 64 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER 630 to 1600 A Thermal current Ith (40°C) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kV) 630 A 800 A 1 250 A 1 600 A 1 000 12 1 000 12 1 000 12 1 000 12 A/B(1) 630/630 630/630 630/630 630/630 630/630 630/630 500/500 630/630 630/630 315/315 100/100 630/630 630/630 630/630 630/630 630/630 500/500 630/630(3) 630/630(3) 630/630 500/500 630/630(3) 630/630(3) A/B(1) 800/800 800/800 630/800 800/800 800/800 800/800 500/500 800/800 800/800 315/315 125/125 800/800 800/800 800/800 800/800 800/800 630/630 800/800(3) 800/800(3) 800/800 630/630 800/800(3) 800/800(3) A/B(1) 1 250/1 250 1 250/1 250 1 000/1 000 1 250/1 250 1 250/1 250 1 000/1 000 800/800 1 250/1 250 1 000/1 000 400/400 200/200 1 250/1 250 1 000/1 000 800/800 800/800 1 250/1 250 800/800(3) 800/800(3) 1 250/1 250 800/800(3) 800/800(3) 800/800(3) A/B(1) 1 600/1 600 1 250/1 250 1 000/1 000 1 600/1 600 1 600/1 600 1 000/1 000 800/800 1 600/1 600 1 250/1 250 400/400 200/200 1 600/1 600 1 250/1 250 800/800 800/800 1 600/1 600 1 000/1 000 800/800(3) 800/800(3) 1 600/1 600 1 000/1 000 800/800(3) 800/800(3) Operational power in AC-23 (kW) At 400 VAC without pre-break in AC-23 (kW)(1)(4) At 500 VAC without pre-break in AC-23 (kW)(1)(4) At 690 VAC without pre-break in AC-23 (kW)(1)(4) 355/355 355/355 90/90 355/355 355/355 110/110 560/560 560/560 185/185 560/560 560/560 185/185 Reactive power (kvar) At 400 VAC (kvar)(4) 290 365 575 Fuse protected short-circuit withstand (kA rms prospective) Prospective short-circuit (kA rms)(5) Associated fuse rating (A)(5) 100 630 70 800 100 1 250 120 2 x 800 Short-circuit capacity Rated short-time withstand current 0.3 s. ICW (kA eff.) Rated peak withstand current (kA peak)(5) 50 55 50 55 100 100 100 110 Connection Min. connection wire range Minimum Cu busbar section (mm2) Maximum Cu cable section (mm2) Maximum Cu busbar width (mm) Tightening torque min (Nm) 2 x 150 2 x 30 x 5 2 x 300 63 20 2 x 185 2 x 40 x 5 2 x 300 63 2 x 60 x 5 4 x 185 100 20 2 x 80 x 5 6 x 240 100 40 Mechanical characteristics Durability (number of operating cycles)(6) Operating effort (Nm) Weight of a 3 pole device (kg) Weight of a 4 pole device (kg) 5 000 45 8 9.5 4 000 45 8.5 10 4 000 45 11 14 3 000 60 16.5 20.5 Rated operational currents Ie (A) Rated voltage 400 VAC 400 VAC 400 VAC 500 VAC 500 VAC 500 VAC 500 VAC 690 VAC(2) 690 VAC(2) 690 VAC(2) 690 VAC(2) 220 VDC 220 VDC 220 VDC 220 VDC 440 VDC 440 VDC 440 VDC 440 VDC 500 VDC 500 VDC 500 VDC 500 VDC Load duty category AC-21 A / AC-21 B AC-22 A / AC-22 B AC-23 A / AC-23 B AC-20 A / AC-20 B AC-21 A / AC-21 B AC-22 A / AC-22 B AC-23 A / AC-23 B AC-20 A / AC-20 B AC-21 A / AC-21 B AC-22 A / AC-22 B AC-23 A / AC-23 B DC-20 A / DC-20 B DC-21 A / DC-21 B DC-22 A / DC-22 B DC-23 A / DC-23 B DC-20 A / DC-20 B DC-21 A / DC-21 B DC-22 A / DC-22 B DC-23 A / DC-23 B DC-20 A / DC-20 B DC-21 A / DC-21 B DC-22 A / DC-22 B DC-23 A / DC-23 B (1) Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 pole in series by polarity. (4) The power value is given for information only, the current values vary from one manufacturer to another. (5) For a rated operational voltage Ue = 400 VAC. (6) Increased endurances: please consult us. SOCOMEC General Catalogue 2011-2012 65 ‹ SIDER - Dimensions Front operation SIDER ND 125 to ND 500 A Direct operation L 4 T T R 2 sider_059_b_1_x_cat AC AA BA N 70° I Y Z 0 1 W H C T 1. Terminal shrouds 2. 1 or 2 NO/NC ACs for pre-break and signalling. A Rating (A) Overall dimensions A 3p. A 4p. C Terminal shrouds AC Switch body H L Switch mounting N R Connection T W Y Z AA BA ND 125 ND 200 ND 250 ND 315 ND 400 ND 500 160 160 232 232 280 280 178 178 173 173 173 173 268 268 350 350 360 360 82 82 77 77 77 77 130 130 162 162 172 172 5 5 6 6 6 6 36 36 60 60 66 66 3 3 3 3 3 3 20 20 20 20 20 20 162 162 195 195 214 214 141 141 165 165 175 175 60 fix 60 196 196 322 322 346 346 36 36 31 31 31 31 8 8 10 10 10 10 External front operation 95 min. 4 J 25 H 77.5 R Ø 78 N BA 125 AA AC 1 2 W 77.5 sider_103_c_1_x_cat 45 3 20 T 1. 1 or 2 NO/NC ACs for pre-break and signalling. 2. Terminal shrouds 66 T F Rating (A) Terminal shrouds Switch body AC F 3p. F 4p. H J Switch mounting N R Connection T W AA BA ND 125 ND 200 ND 250 ND 315 ND 400 ND 500 268 268 350 350 360 360 184 184 294 294 318 318 137 137 132 132 132 132 54 54 85 85 91 91 130 130 162 162 172 172 36 36 60 60 66 66 8 8 10 10 10 10 162 162 195 195 214 214 141 141 165 165 175 175 148 148 234 234 252 252 5 5 6 6 6 6 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER SIDER 630 to 1600 A Direct front operation External front operation A F M 160 Z 90.5 1 Y 60 295 min. T T T X2 30 ° X1 90 sider_061_e_1_x_cat CA 330 460 AA BA 220 80 0 350 11 U W V CA 12.5 240 I 14 1. Terminal screens Rating (A) Overall dimensions A 3p. A 4p. Switch body F 3p. F 4p. Switch mounting M 3p. M 4p. Connection T U V W X1 X2 Y Z AA BA AC 630 800 1 250 1 600 463 463 555 555 358 358 450 450 255 255 347 347 80 80 120 120 50 60 65 80 13 42.5 47.5 46.5 46.5 52.5 47.5 60.5 60.5 6 6 7 15 106 106 107 111 300 320 330 360 260 20 543 543 675 675 438 438 560 560 335 335 457 457 40 50 63 80 Side operation SIDER ND 125 to ND 500 A External side operation H 4 L 60 fix 60 J 25 77.5 R 1 125 N BA AA 2 W 77.5 sider_090_d_1_x_cat AC 3 T 3 20 45 T 1. 1 or 2 NO/NC ACs for pre-break and signalling. 2. Terminal shrouds 3. Max. length with shaft extension: 230 mm F Rating (A) Terminal shrouds Overall dimensions AC F 3p. F 4p. Switch body H J L Switch mounting N R Connection T W AA BA ND 125 ND 200 ND 250 ND 315 ND 400 ND 500 268 268 350 350 360 360 137 137 132 132 132 132 36 36 31 31 31 31 130 130 162 162 172 172 36 36 60 60 66 66 8 8 10 10 10 10 162 162 195 195 214 214 141 141 165 165 175 175 148 148 234 234 252 252 SOCOMEC General Catalogue 2011-2012 184 184 294 294 318 318 54 54 85 85 91 91 5 5 6 6 6 6 67 ‹ SIDER - Dimensions (continued) Side operation (continued) SIDER 630 to 1600 A Direct side operation External side operation 201 Z Y F M = 1 V CA 72 2 = W U 240 210 0 11 sider_065_c_1_x_cat CA 90° 28 460 AA BA 220 I 30 X1 T T A T X2 14 61 1. Terminals protection screen 2. Max length with shaft extension: 111 mm Rating (A) Overall dimensions A 3p. A 4p. Switch body F 3p. F 4p. Switch mounting M 3p. M 4p. Connection T U V W X1 X2 Y Z AA BA AC 630 800 1 250 1 600 387 387 479 479 280 280 372 372 255 255 347 347 80 80 120 120 50 60 65 80 13 42.5 47.5 46.5 46.5 52.5 47.5 60.5 60.5 6 6 7 15 147 147 148 152 300 320 330 360 260 20 467 467 599 599 360 360 492 492 335 335 467 467 40 50 63 80 ‹ Dimensions for external handles SIDER ND 125 to ND 500 A Front operation Direction of operation Door drilling S2 type With lock RONIS EL11AP 40 0 90 ° With lock CASTELL K Ø 26 Ø78 28 Ø 37 .5 2 Ø 6.5 28 I Ø 37 4Ø7 4Ø7 79 73 45° 5 3. 45° .5 26 14 14 Ø 37 45 22 24 125 Ø 37 4 Ø 5.5 28 4Ø7 14 14 Handle type 20 20 20 20 Side operation Handle type Direction of operation Door drilling Ø 37 40 Ø78 Right side operation I S3 type With lock RONIS EL11AP 0 With lock CASTELL K Ø 26 Ø78 Ø 37 .5 Ø 37 4Ø7 24 73 28 45° 5 3. 45° .5 26 20 20 210 28 Ø 37 4Ø7 68 2 Ø 6.5 28 4 Ø 5.5 61 4Ø7 22 45 28 ° 79 90 20 20 125 sider_106_a_1_gb_cat S2 type 28 General Catalogue 2011-2012 SOCOMEC Load break switches for power distribution SIDER ‹ Dimensions for external handles (continued) SIDER 630 to 1600 A Front operation Handle type Direction of operation Door drilling S4 type 40 Ø 37 0 Ø78 350 90 ° 28 I 4Ø7 With lock RONIS EL11AP With lock CASTELL K Ø 37 Ø 37 Ø 37 4Ø7 22 79 73 45° 5 3. 45° .5 26 20 20 24 4Ø7 20 20 60 2 Ø 6.5 28 4 Ø 5.5 .5 28 sider_107_a_1_gb_cat Ø 26 28 28 ‹ Connection terminals SIDER 1 250 A ø15 SOCOMEC General Catalogue 2011-2012 19 25 19 63 sider_075_a_1_x_cat 17 25 sider_074_a_1_x_cat 10 sider_073_a_1_x_cat 30 33 50 ø 13 16 x 11 30 33 ø19x11 SIDER 1 600 A 20 40 SIDER 800 A 20 40 20 80 69