Fire Alarm Systems | D7038 Remote Notification Appliance Circuit (NAC) Power Supply D7038 Remote Notification Appliance Circuit (NAC) Power Supply ▶ 6 A of power ▶ Fully supervised outputs ▶ Can be configured for NAC output or constant auxiliary power ▶ Regulated 24 V ouput (nominal) with over-current protection ▶ Built-in NAC pattern ▶ Four Class B, Style Y circuits ▶ Form C trouble relay ▶ Supervised AC, battery, and circuit expander ▶ Ground fault indication ▶ Charger control monitor Use the D7038 to add four additional notification appliance circuits (NFPA 72, Class B, Style Y) to a fire alarm control panel (FACP) or as a power supply for fire-protective signaling systems. This regulated power supply provides up to 6 A of power that is used to recharge batteries and operate both continuous and intermittent alarm loads. This 6 A of power can be distributed through the four Class B, Style Y circuits that are part of the D7038. The D7038 is UL Listed for use in commercial fire alarm applications. Functions Compatible Control Panel Connections The D7038 is compatible with any UL Listed control panel that uses reverse polarity supervised notification outputs with 12 VDC or 24 VDC regulated outputs. It is also compatible with the following Bosch Control Panels: • • • D7022 Two-zone Conventional FACP D7024 Four-zone Addressable FACP D8024 and D10024 Analog FACPs You can connect up to two D7038s to a D7024 Control Panel. The D7024 can individually control each of the four NFPA72 Class B, Style Y NAC outputs for each D7038. The D7024 can also supervise each D7038's power supply. Status Displays There are seven local status display LEDs on the D7038's printed circuit board that monitor the following conditions: High Voltage, AC OK, Low Battery, Loop Trouble, Groun Fault, Output Active and NAC Short. DIP Switch Settings If connected to the D7024's option bus, the D7038 needs its own option bus address. Set this address through the DIP switches. Determine which inputs control which outputs through the NAC Input Variable option. Set Input 1 to control all four NAC outputs or only NAC Outputs 1 and 2. If you choose the latter, Input 2 controls NAC Outputs 3 and 4. If the AC voltage falls below 102 V for over 5 sec, a trouble condition is registered, but not sent to the control panel. The DIP switch setting for AC Failure Time Delay determines the time delay of 1, 6, 12, or 24 hrs before sending an AC failure. The default value is 6 hrs. For the D7022 conventional panel and the D8024 and D10024 analog panels, the D7038 connects through a NAC circuit. No serial bus connection is necessary. www.boschsecurity.com 2 | D7038 Remote Notification Appliance Circuit (NAC) Power Supply Technical Specifications Certifications and Approvals Region Certification USA UL Environmental Considerations UOXX: Control Unit Accessories, System (UL864, 9th edition), UTOU: Control Units and Accessories - Household System Type (UL985), UTRZ: Power Supply Units (UL1481) FM Temperature (operating): +32°F to +120°F (0°C to +49°C) Inputs (NAC) Response Time (input to out- 50 ms maximum put): Voltage (input): 9 VDC to 30 VDC CSFM 7165-1615: 147 Mechanical Properties NYC-MEA 12-92-E, Vol. 14 12-92-E, Vol. 14 Color: Red 26-02-E, Vol. III 26-02-E, Vol. III Dimensions (H x W x D) without door: 20.4 in. x 14.8 in. x 4.1 in. (52 cm x 38 cm x 10.4 cm) Material: cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Installation/Configuration Notes Compatible Products The following products are compatible with the D7038 Remote NAC Power Supply: Category Product ID Product Description Batteries D126 12 V, 7 Ah battery D1218 12 V, 18 Ah battery D1224 12 V, 24 Ah battery D1238 Outputs Auxiliary Current (output): 850 mA maximum Voltage (output): 24.1 VDC or 27.4 VDC NAC Output per circuit: 2.5 A maximum 12 V, 38 Ah battery Output (total): 6A Class B to Class A NAC converter Voltage (output) at +77°F (+25°C): AC operation: 27.4 ± 0.1 VDC DC operation: 24.1 ± 0.6 VDC Voltage (standby): -5.0 VDC Modules D7015 Four-wire Smoke Detectors Refer to Technogram (P/N: 38779) NAC Devices Refer to Technogram (P/N: 38779) Trouble Relay Magnetic Door Holders Refer to Technogram (P/N: 38779) Contact Type: Form C Rating (contact): 1.5 A at 32 VDC Wiring All wiring is connected to the power supply board by screw terminals that can accept up to 12 AWG (2.3 mm) wire. Parts Included Quant. Component 1 D7038 board 1 AE4 Large Enclosure (red) 4 2.21 kΩ end- of-line (EOL) resistors (P/N: 25899D) 1 Hardware pack Power Requirements Current (total output): 6 A maximum Power (primary input): 120 VAC, 2.5 A maximum, 60 Hz Voltage (battery): 24 VDC nominal Voltage (ripple) 250 mVpp maximum Ordering Information D7038 Remote Notification Appliance Circuit (NAC) Power Supply Adds four additional notification appliance circuits (NFPA 72, Class B, Style Y) to a fire alarm control panel D7038 Accessories KEY‑625 Replacement Key Replacement key Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems Inc. 2010 | Data subject to change without notice T1245646475 | Cur: en-US, V5, 4 Jul 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com KEY-625