G eiger-Müller counter tube : 

Adjustment  .

2011/10/17 English ver1.01

( CreationDate 2011/07/22 )

Assembly Desk

( http://a-desk.jp/ ) page :  01

KIT MANUAL 

No.

 

3

Air Geiger-Müller counter Kit

[KIT MANUAL]

This book let is Simple Explanation about Radiation and Geiger-Muller Counter Tube.

All so How to Adjust this kit.

  (Please do adjust kit when you finish building )

1

About Radiation

1   : 

Types of Radiation

Radiation has these types.

Radiation types Essence

Alpha Rays (α)

Beta Rays (β)

Helium atomic nucleus Particle Beam.

Electron beam.

Gamma Rays (γ)

X Rays (x)

Neutron

Heavy Ion

Electromagnetic wave by Radioactive

Decay from Atomic nucleus.

Electromagnetic wave span is shorter

Than Artificially made ultra violet.

Neutron Particle Beam.

Ionized atom. Carbon , Neon , Argon

Electric charge Permeability

+2

-1

0

0

0

Small 

About Medium 

High 

High 

(Shut out by Paper)

(Shout out by Tick concrete and lead plate )

(Shout out by Tick concrete and lead plate )

About Medium 

More than +1 Small

(Shout out by AluminumSheet)

(Shout out by water )

Caution ; Gamer rays and X rays are same electromagnetic wave  but distinguish by occurrence.

This Air Geiger Counter kit can measure [α Rays][β Rays][γ Rays].

Atom Types of Radial Rays Radiation Permeability

Alpha Rays

Beta Rays

Gamma  or  X Rays

Paper Thin Aluminum Lead plate

1

About Radiation

2   : 

Well known radiation

Around you there are emissive Radiation.These are few examples.

page :  02

Radiation(Beta ray) is used for Electrolytic dissociation to Improve lighting speed.

Source of radiation is Promethium147 (Pm-147 half-life period 2.6234 year)

Sealed in glass tube so Beta ray doesnʼ t come out. nowadays switched to Long-term

Luminous paint. after 2002 manufacture process has ended.

The glow lamp flash in violet used long-term luminous paint. old glow lamp which used

Promethium147 has degrade. because of half-life of promethium147 is 2.6234 year.

Lamp mantles used in lantern. To improve color Radiation ( Alpha ray )was used.

Source of radiation is Thorium (Th-232) nowadays not used.

Old clock and watches use Promethium147 (Pm-147)for luminous paint.

Nowadays switched to long-term luminous paint. Stop using them after year 1993.

Ionize Smoke detector use Americium241 (Am)

Use radiation for Ionizing effect to detect smoke.

Thorium (Th-232) was used for filament in a vacuum tube.

Potassium radioisotope40K (Beta decay) in Natural world.

Potassium is one of three measure fertilizer. The nutrient all living creature

Have got or necessary. Edible kelp [Kombu] (5300mg/100g) and

Potash fertilizer (content about 10%) contain high potassium.

Radiation rays falling from space. Most of them are absorb by terrestrial magnetism or

Atmospheric layer. Still high permeability cosmic ray has fallen to ground.

Or collide with atmosphere to become another type of radiation rays to fall.

The Sun is burning by nuclear fusion the sun produce radiation rays. (the solar wind)

By the cosmic ray ionization Aurora has observe in north and south pole.

Thorium (Th-232) rod is used to weld makes arc discharging easier.

Extract heat to generate by uranium nuclear fission.

Emission all sorts of Radiation rays while fission.

X-rays are artificial magnetic wave. Same as  Gamer rays.

Photo-genesis by Electron gun fires

Electron (Beta Rays) to hit fluorescent material on the

Surface when Electron beam collide with

Shadow mask (Aperture mask) generate X rays.

To shout out X rays Braun tube is made of lead glass.

JEITA (Japan Electronics and Information Technology Industries Association)

Provision Measurement method of X rays leakage from Braun tube. Small amount of X ray is leaking.

When you watch TV for 24 hours same amount of radiation you will receive as one X-ray examination.

2

Mechanism of Geiger-Muller Counter Tube

page :  03

1   : 

What is Geiger-Muller Counter Tube

Radiation detector invented in 1925 German Physicist “ Johannes Wilhelm Geiger  ” and student “ Walter Müller ” . 

Shorten by GM Counter tube. In a Metallic tube (Cathode) Core wire (Anode) place in center.  

Needs high voltage on the other hand it can count radiation one by one.     

How ever unable to count strength. (speed & energy) To count the strength need proportional counter

Which made similar stricture. count the number of radiation comparative high sensitivity.  

Suit for Alpha rays and Beta rays. Able to count Gamer ray but percentage is very low. 

2   : 

How the Geiger-Muller Counter Tube Works

Incoming radiation (α、β、γ rays).

Collide with gas molecule (inert gas) to ionize gas.

Generated electron accelerate in strong magnetic field. 

Accelerate electron collide again with gas to excite.

Excite gas  return to ground state develop ultraviolet.   

Ultraviolet ionize gas produce electron avalanche.  

Electron avalanche contact anode detect as pulse. 

Electric Discharge Inhibition Gas  (Butane Gas)

Receive positive electric charge. Stops electron avalanche.

The other side positive ionized gas decrease electric field.  

Electron avalanche closure.

Positive ionized gas shift to cathode. 

   Because of molecule it takes time to shift.

Positive ionized gas arrive to cathode. 

   Flow electric current to  encourage electric avalanche.

Leave it like this electron avalanche doesnʼ t stop. 

   Fill up case with electric discharge inhibition gas. 

   to prevent electric current.

Electric discharge inhibition gas receive

   positive electric charge.

Electric discharge inhibition gas

   arrival cathode. This time doesnʼ t

   encourage electron avalanche.  

Electric discharge inhibition gas

   returns to molecule.

Anode

+3000V ~ 4000V

Cathode

0V

Radiation

Inert Gas  (Nitrogen)

Radiation collide with Inert gas Ionize gas

 : 

Air Geiger-Muller Counter Tube

Air Geiger-Muller counter tube is use object around you to build Geiger-Muller counter tube.

Here is comparison with Standard Geiger-Muller counter tube and Air Geiger-Muller counter tube.  

Specification Standard Geiger-Muller counter Air Geiger-Muller counter

Inert Gas Ar (Argon),  He (Helium)

Continuance Electric Discharge Inhibition Gas Halogen gas

N (Nitrogen) 

Butane gas

Internal pressure

Applied Voltage

Entrance window

0.1 atm

500-700V

Mica

1 atm

3000-5000V

Food wrapping sheet

3

How to use Air Geiger-Muller Counter Kit

1   : 

Operating guide

When you finish building air Geiger counter kit.

Switch on the power applied voltage to Geiger-Muller tube will increase.    

About first 1 minutes voltage & tube are unstable wait until stable.

Voltage setting can be adjust with a switch next to USB connector on the side.  

To stop operating error this switch is small & deep. Use tip of ballpoint pen to push it.   

Monitoring logs can be

Made follows.

Use USB cable to connect

This counter with PC to

Start data logger software. 

Unit can be witch to

[cpm]⇔[μSv] to display.

Data logging software

The Picture next to

This in Japanese but

English version

Will be available.

page :  04

Real time Display

[cpm] , [µSv/h]

   unit select

Start Logging

End of Logging

Mesurring end

Clear Data

CSV Format

Geiger-Müller counter tube :  Data logger .

 : 

How to Adjust Air Geiger-Muller Counter Tube

[1] Plateau voltages

When you increase impression voltage of Geiger-Muller counter Tube. Counting number will increase as

Raising voltage. counting number will be stable when voltage reach certain range. 

This range called “ Plateau voltage ” . Radiation counting will be done in this Plateau range.

The range plateau voltage of ordinary Geiger-Muller counter tube is about 500- 700V.  

Number is depend on the tube.  However the case of air Geiger-Muller counter tube

Plateau voltage will depend on how you make the tube or amount of  butane gas used. 

Use this kit to build a tube. Plateau voltage range will be 3000V-4000V.

[2] Adjustment Radioactive Material 

Tuning air Geiger-Muller tube easier to adjust when you have radioactive material. 

Here is couple of things easier to find.  reduced salt food products using “potassium chloride(KCL)” instead of NaCl can be detect small amount of radiation.

Look at the label of ingredient list and choose high in potassium.

Used in accessory etc.  uranium beads release radiation can be detect that.

HIGH VOLTAGE

WARNING

ELECTRICAL

SHOCK

From next page parts need to tune in High voltages 3000V~4000V

When you are tuning please take extra care for electrocution.

For building by a child please supervise with adult.

3

How to use Air Geiger-Muller Counter Kit

2   : 

Adjustment for Air Geiger-Muller Counting Tube

[3] Adjustment for Air Geiger-Muller Counting Tube

To adjust tube there are two ways to do by  [ Butane gas density ]  or  [ Impression voltage ]  .

[ Butane gas density ]

When you increase [Butane gas density] plateau voltage will lowers.

When you increase [Butane gas density] too much. One radiation detecting count multiple numbers.

[Butane gas density] too low difficult to detect.

To start filling butane gas (lighter fluid) by guessing. Increase voltage slowly from 3000V.

page :  05

Butane gas is heavier than air. Fill up like pouring.  

While you are filling please watch out for fire. To do this make sure switch off and remove battery.

When gas has filled tube install incident film. 

How to install that look back [KIT MANUAL no1( 7p 1-5 [Install Incidence Film] ) ]

Butane gas doesnʼ t  diffuse instant wait for few minutes.

[ Impression voltage ] This rating and graph testing radiation has used.

3620

3630

3640

3650

3660

3670

3680

3690

3700

V  (High voltage) cpm

3500 0

3510 3

3520

3530

3540

3550

3560

3570

3580

3590

3600

3610

6

20

35

68

101

119

149

173

190

189

192

196

190

218

189

210

210

456

1519

Voltage    CPM result for measurement            and that graph    

Turn on Increase voltage one minutes at time to find plateau voltage.

(Between 3000V to 4000V  voltage for horizontal axis CPM for vertical axis to draw a graph)

Plateau voltage  is depend on quality of tube.

When you make it nice plateau voltage appears under 3200V.

Adjustment is completed when  10 ~ 40CPM in plateau voltage.

Close by testing radioactive material to confirm motion.

[ If Plateau Voltage Doesnʼt  Show up ]

[Plateau Voltage]

At one radiation detect looks like counting multiple number then too much gas.

Increase voltage near 4000V but if CPM dose not raise then too less gaas.   

Try it until right adjusting can be made. Take time please be patient!! 

4

If Difficult to Measure

1   : 

Re cheeking point

[1] Voltage doesnʼt increase. 

Voltage doesnʼ t increase to setting.

 (under 1000V)

Question

Voltage doesnʼ t increase to setting.

 (over 1000V)

Question

[2] Voltage increase even doesnʼt detect.

Please check list of things below.

Make sure tube is made right again.

Anode length is same as manual?

Tip of Anode turn in thin?   

Is tube is air tight?

Butane gas setting is ok?  page :  06

006p Battery is getting weak? 

Please change to new battery.

Answer

Answer

2   : 

If You wounder Broken? 

When you switch on but LCD doesnʼ t show. 

Question

High frequency coming from this kit.

Question

When kit face sun it detect radiation.

Question

Battery runs out too fast. 

Question

Use screw driver to turn potentiometer [VR1] 

When you do this please watch out for high voltage.

Answer

It is normal.

While boosting transformer it oscillate.    

Answer

It is working fine.

Ultraviolet from the sun interfere with detecting. 

When you measure radiation color incidence film to black or measure at night.

Answer

Turn off LCD back light to save energy.  

(Use soldering iron to remove J1 at back of LCD )

Answer

G eiger-Müller counter tube : 

Adjustment  .

  0

 

 : 

MEMO

page :  07

G eiger-Müller counter tube : 

Adjustment

1   : 

Adjustment For Display

[USB mini B Receptacle]

Use USB to connect to PC

To take data logging  

(Works stand alone)

 .

page :  08

[LCD Display]

CPS (count in 1 second)

CPM (count in 1 minutes)

Aiming voltage (Set it best detecting)

Present voltage (control to aiming voltage)

Change display to simplified µSv/h

[Voltage Adjust Switch]

Adjust to quality of tube.

Sensitive adjusting can be done.

Increase or decrease

Voltage by 5V at the time.

[Geiger-Muller Tube]

Radiation detect as pulse.

[Power switch]

Turn it off when not in use.

2   : 

production notes

(Produce & Develop By)  Bit Trade One, LTD

8-10-18 Friend building Sagamihara Chuouku Sagamihara city Kanagawa Prefecture

e 電子工房

E i n s t e i n ' s   e l e c t r o n i c   l a b

(Supervision&technical cooperation with)  Mr Yasuyuki Onodera

(cooperate with)  Absolute Inc

( Air Geiger-Muller counter Tube WebSite )

We have more products on this pege but unfortunately this service is only In Japan at the moment.

How ever may change in the future so please look out for. 

If you fined any fault with this products please send us e-mail  info@bit-trade-one.co.jp

Download