TIA/EIA-606-A TIA/EIA-606-A

advertisement
®
NET WORK CONNECTIVITY GROUP
TIA/EIA-606-A
LABELING COMPLIANCE
BROCHURE
(Featuring the PANDUIT ® ULTIMATE ID ™ Network Labeling System)
TIA/EIA-606-A
Labeling Compliance
Brochure
For compliance with the TIA/EIA-606-A standard, PANDUIT ® has the solution. This brochure
will walk you through the labeling requirements of the standard and introduce you to
identification solutions specifically designed to comply with TIA/EIA-606-A. The
standard establishes guidelines for owners, end users, manufacturers, consultants,
contractors, designers, installers, and facility administrators involved in the
administration of the telecommunications infrastructure. Proper identification of your
network allows moves, adds, changes, trouble shooting, and repairs to be accomplished
faster and more efficiently. PANDUIT offers a full line of network connectivity products,
labeling products, software, and printers to assist you with TIA/EIA-606-A compliance.
The ULTIMATE ID ™ Network Labeling System featured in this brochure was designed
specifically with the TIA/EIA-606-A standard in mind. It includes faceplates, surface mount
boxes, patch panels, marker ties, labels for desktop printers, and the PANAC–EA ™ LS7
hand-held thermal transfer printer. All ULTIMATE ID hardware uses labels with a
common compact height; this not only enhances the appearance of the installation, but
also saves time and money by providing a clear and efficient way to label according to the
TIA/EIA-606-A standard. All labels are positioned adjacent to, centered and parallel to the
module they are identifying. The appearance of the installation can be further enhanced
by using a consistent font size throughout the installation. The PANAC– EA LS7 printer and
PANDUIT desktop labeling software can both be used to mechanically print labels with the
same font.
For detailed information on related PANDUIT identification products, request any of
the following:
• ULTIMATE ID Network Labeling System Catalog: SA-IDCB01
• PAN-CODE ™ Identification and Labeling Solution Products: SA101N315C
• PANAC–EA LS7 Hand-Held Thermal Transfer Printer: SA-IDCB1000A
• VIPER ™ LS6 Portable Thermal Transfer Printer: SA-ID07BR01A
• ULTIMATE ID Labeling Software for WINDOWS^: SA-IDCB11
• PAN-MARK ™ 2.5 Labeling Software for WINDOWS: SA-IDCB1043A
• Detailed printing instructions for ULTIMATE ID labels with the
PANAC–EA LS7 Hand-Held Thermal Transfer Printer: SA-IDSP01
^WINDOWS is a registered trademark of Microsoft Corp.
Table of Contents
Roadmaps
2-3
Horizontal Link Identification - Patch Panel
4
Horizontal Link Identification - Outlet
5
Cable Identification
6-7
Telecommunications Space Identification
8
Telecommunications Main Grounding Busbar and
Grounding Busbar Identification
9
Horizontal Link Identification - IDC Punch Down Block
10
Firestopping Location Identification
11
Horizontal Link Identification - Connector
12
Portable Printers
13
Computer Printable Software
14
Overview of TIA/EIA-606-A
15
Horizontal Link Identifier Labeling Format
16
1
For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory).
TIA/EIA-606-A Labeling Compliance in the Telecommunications Space Roadmap
2
7
6
3
1
6
5
4
2
1
Telecommunications Space
Identification (see page 8)
5
Horizontal Link Identification —
IDC Punch Down Block (see page 10)
2
Cable Identification — Backbone
(see pages 6-7)
6
Cable Identification —
Horizontal Link (see pages 6-7)
3
Telecommunications (Main) Grounding
Busbar Identification (see page 9)
7
Firestopping Location Identification
(see page 11)
4
Horizontal Link Identification —
Patch Panel (see page 4)
TIA/EIA-606-A Labeling Compliance in the Work Area Roadmap
6
9
6
Cable Identification — Horizontal Link
(see pages 6-7)
8
Horizontal Link Identification — Outlet
(see page 5)
9
Horizontal Link Identification — Connector
(see page 12)
8
3
Horizontal Link Identification - Patch Panel
U LT I M AT E I D ™™N e t w o r k L a b e l i n g S y s t e m f o r Pa t ch Pa n e l s
Section 5.1.2 States
A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements.
In the Telecommunications Space (TS), each patch panel port shall be labeled with the “an” portion of the
identifier. This requirement may be met by labeling a patch panel with the “a” portion of the identifier, and each
port with the “n” portion where:
a = one to two alpha characters uniquely identifying a single patch panel, or a group of patch panels with
sequentially numbered ports
n = two to four numeric characters designating the port on a patch panel in the TS
For example:
“A07” = patch panel A, position 07
The ULTIMATE ID patch panel and labeling system allows you to center the “an”
identifier over each port.
All ULTIMATE ID Patch Panels can be identified with the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number
UILJ4
Part Description
Four port, white non-adhesive polyester labels, 66 labels
per sheet
Width
in
mm
2.585
65.65
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
0.236
5.99
5
50
*Order number of sheets required in multiples of Std. Pkg. Qty.
For detailed information on ULTIMATE ID patch panels and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
UILS7BW
Part Description
Black/white non-laminated polyester label cassette
Height
in
mm
0.236
5.99
Length
ft
m
26.200
8.00
Std. Std.
Pkg. Ctn.
Qty.* Qty.
1
20
*Order number of cassettes required.
For non-adhesive labeling solutions, do not remove liner from the label.
Patch panels which are not part of the ULTIMATE ID Network Labeling System can be identified by utilizing the LS7-25-1 label cassette as
–EA LS7 full line product bulletin, request SA-IDCB1000A.
an adhesive label. For a PANAC
4
Horizontal Link Identification - Outlet
U LT I M AT E I D ™™ N e t w o r k L a b e l i n g S y s t e m f o r O u t l e t s
( F a c e p l a t e s / S u r f a c e M o u n t B o xe s )
Section 5.1.2 States
A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements.
In the work area, each individual telecommunications outlet/connector shall be labeled with the horizontal link
identifier. The labeling shall appear on the connector, faceplate, or MUTOA, in a way that clearly identifies the
individual connector associated with the particular identifier. A horizontal link identifier shall have a format of
“fs-an” where:
f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space)
s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located
a = one to two alpha characters uniquely identifying a single patch panel or a group of
patch panels with sequentially numbered ports, an IDC connector, or a group of IDC
connectors, serving as part of the horizontal cross-connect
n = two to four numeric characters designating the port on a patch panel in the TS or the
section of an IDC connector on which, a four-pair horizontal cable is terminated in the TS
For example:
“1A-B02” = origination point first floor, TS A, patch panel B, position 02
Each ULTIMATE ID faceplate/surface mount box is designed in a way that allows you to
center the “an” identifier clearly over each connector, while the “fs” identifier can
be placed in the station space.
All ULTIMATE ID Faceplates/Surface Mount Boxes can be identified with the
following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number**
Width
in
mm
Part Description
Height
in
mm
Std. Std.
Pkg. Ctn.
Qty.* Qty.
UILJ1
One port label, white non-adhesive polyester labels, 264 labels per sheet
0.680
17.27
0.236
5.99
5
50
UILJ2
Two port labels, white non-adhesive polyester labels, 132 labels per sheet
1.315
33.40
0.236
5.99
5
50
UILJ3
Three port labels, white non-adhesive polyester labels, 99 labels per sheet
1.950
49.53
0.236
5.99
5
50
UILJ4
Four port labels, white non-adhesive polyester labels, 66 labels per sheet
2.585
65.66
0.236
5.99
5
50
UILJ6
Six port labels, white non-adhesive polyester labels, 66 labels per sheet
Label sheets with 40-one port, 60-two port, 3-three port and 24-four port labels
per sheet, white non-adhesive polyester
3.855
97.92
0.236
5.99
5
50
—
—
0.236
5.99
5
50
UILJCOMBO
*Order number of sheets required in multiples of Std. Pkg. Qty.
**For Electrical Ivory labels, add EI at end of part number.
For detailed information on ULTIMATE ID faceplates and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
UILS7BW
Part Description
Black/white non-laminated polyester label cassette
Height
in
mm
0.236
5.99
Length
ft
m
26.200
Std. Std.
Pkg. Ctn.
Qty.* Qty.
8.00
1
20
*Order number of cassettes required.
For non-adhesive labeling solutions, do not remove liner from the label.
Faceplates which are not part of the ULTIMATE ID Network Labeling System can be identified by utilizing the LS7-25-1 label cassette as an adhesive
label. Non-ULTIMATE ID faceplates which accept 0.4 inch high labels can be identified by utilizing the LS7-38-1 label cassette as a non-adhesive
label. For a PANAC–EA LS7 full line product bulletin, request SA-IDCB1000A.
For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory).
5
Cable Identification
PA N D U I T ®® C a b l e I d e n t i f i c a t i o n P r o d u c t s
Section 5.1.2 States
A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements.
Each end of a horizontal cable shall be labeled within 300 mm (12 in) of the end of the cable jacket with the
horizontal link identifier, which shall be visible on the exposed part of the cable jacket. This shall include each
cable in the Telecommunications Space (TS), at the work area, and at a Consolidation Point (CP), if present.
A horizontal link identifier shall have a format of “fs-an” where:
f=
s=
a=
n=
numeric character(s) identifying the floor of the building occupied by the TS
alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space
is located
one to two alpha characters uniquely identifying a single patch panel or a group of patch panels with
sequentially numbered ports, an IDC connector, or a group of IDC connectors serving as part of the
horizontal cross-connect
two to four numeric characters designating the port on a patch panel in the TS or the section of an
IDC Connector on which a four pair horizontal cable is terminated in the TS
For example:
“1A-B01” = cable origination point first
floor, TS A, patch panel B,
position 01
ULTIMATE ID ™ Solution
UILJ2 Label
and UICBM1M
Marker Tie
Non-ULTIMATE ID Solutions
S100X150FAJ
Self-Laminating
Label
S100X160FAJ
Self-Laminating
Label and
NWSLC-3 Sleeve
Section 6.1.1 States
A unique building backbone cable identifier shall be assigned to each backbone cable between two TSs in one
building and it shall have a format of “fs1/fs2-n” where:
fs1 = TS identifier for the space containing the termination of one end of the backbone cable
fs2 = TS identifier for the space containing the termination of the other end of the backbone cable
n = one to two alphanumeric characters identifying a single cable with one end terminated in the TS
designated fs1 and the other end terminated in the TS designated fs2
In this format, the TS with the lesser alphanumeric identifier shall be listed first. If the entire cable is within one
TS, the format may be fs1/fs1-n. All building backbone cable identifiers in a single infrastructure should have the
same format where possible. The backbone cable identifier shall be marked on each end of the backbone cable
within 300 mm (12 in) of the end of the cable jacket.
Ultimate ID Solution
Non-ULTIMATE ID Solution
For example:
“1A/2A-1” = TS A on first floor to
TS A on second floor, cable 1
UILJ2 Label and
UIHL12-X0 or
UIHL22X0 Marker Tie
LS7-75NL-1
Label Cassette
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can
be generated by a mechanical device and are made of durable polymer construction
that will withstand the effects of moisture, heat and time.
6
Cables and Cable Bundles can be identified with the following labels:
ULTIMATE ID ™ Network Labeling System Solutions
Desktop Laser / Ink Jet Printing Solution
Part Number
UILJ2**
Width
in
mm
Part Description
Two port labels, non-adhesive white polyester labels, 132 labels
per sheet
1.315
33.40
Height
in
mm
0.236
5.99
Std. Std.
Pkg. Ctn.
Qty.* Qty.
5
50
*Order number of sheets required in multiples of Std. Pkg. Qty.
**For Electrical Ivory labels, add EI at end of part number.
For use with UICM1M-C, UIHL12-XO and UIJL22-XO ULTIMATE ID Marker Ties to mark cables and bundles up to 1 inch in diameter.
For detailed information on ULTIMATE ID patch panels and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01.
PANAC–EA ™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
UILS7BW
Height
in
mm
Part Description
0.236
Black/white non-laminated polyester label cassette
5.99
Length
ft
m
26.200
8.00
Std. Std.
Pkg. Ctn.
Qty.* Qty.
1
20
*Order number of cassettes required.
For non-adhesive labeling solutions, do not remove liner from the label.
NON-ULTIMATE ID Network Labeling System Solutions
Desktop Laser / Ink Jet Printing Solution
Part Number
Width
in mm
Part Description
Length
in mm
Print-O
On Min. Cable Max. Cable Std. Std.
Height Diameter Diameter Pkg. Ctn.
in mm in mm in mm Qty.* Qty.
S100X150FAJ White self-laminating polyolefin labels
1.000 25.40 1.500 38.10 0.50 12.70 0.16 4.04 0.32 8.09 2500 12500
S100X160FAJ^ White self-laminating polyolefin labels
1.000 25.40 1.600 40.64 0.80 20.32 0.25 6.47 0.25 6.47 2500 12500
S100X225FAJ† White self-laminating polyolefin labels
1.000 25.40 2.250 57.15 0.75 19.05 0.24 6.07 0.48 12.13 1000 5000
*Order number of labels required in multiples of Std. Pkg. Qty.
^Use this label with NWSLC-2 LABELCORE ™ to identify 2 mm fiber, and with NWSLC-3 LABELCORE to identify 3 mm fiber.
†Use this label with NWSLC-7 LABELCORE to identify 3 mm duplex fiber.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
Width
in
mm
Part Description
Length
ft
m
Std. Std.
Pkg. Ctn.
Qty.* Qty.
LS7-75NL-1^
Black/white non-laminated polyester label cassette
0.708
17.98 26.200
8.00
1
20
LS7-75NL-2^
Black/clear non-laminated polyester label cassette
0.708
17.98 26.200
8.00
1
20
*Order number of cassettes required.
^Use these labels with NWSLC LABELCORE sleeves to identify fiber.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Number
Width
in mm
Part Description
Length
in mm
Print-O
On Min. Cable Max. Cable Std. Std.
Height Diameter Diameter Pkg. Ctn.
in mm in mm in mm Qty.* Qty.
1
White self-laminating polyolefin labels, 250/roll
1.000 25.40 1.500 38.10 0.50 12.70 0.16 4.04 0.32 8.09
S100X160FA6^ White self-laminating polyolefin labels, 250/roll
1.000 25.40 1.600 40.64 0.80 20.32 0.25 6.47 0.25 6.47
1
10
S100X225FA6† White self-laminating polyolefin labels, 150/roll
1.000 25.40 2.250 57.15 0.75 19.05 0.24 6.07 0.48 12.13
1
10
S100X150FA6
10
*Order number of rolls required.
^Use this label with NWSLC-2 LABELCORE to identify 2mm fiber, and with NWSLC-3 LABELCORE to identify 3mm fiber.
†Use this label with NWSLC-7 LABELCORE to identify 3mm duplex fiber.
LABELCORE Fiber Optic Cable Identification System
Apply LABELCORE
Sleeve to cable
Part Number
NWSLC-2
NWSLC-3
NWSLC-7
Wrap label around
LABELCORE Sleeve
Part Description
Cable identification sleeve, 2mm fiber cable, yellow
Cable identification sleeve, 3mm fiber cable, orange
Cable identification sleeve, 3mm duplex fiber cable, white
Std. Pkg. Std. Ctn.
Qty*
Qty
100
100
100
1000
1000
1000
*Order number of sleeves required in multiples of Std. Pkg. Qty.
Locate on straight section of cable at least 2" from fiber boot.
For Technical Assistance, Call:866-405-6654 (Outside the U.S., see back cover for Regional Directory).
7
Telecommunications Space Identification
PA N D U I T ®® N
Neettw
wo
orrk
k LL aab
beelliin
ng
g P
Prro
od
du
uccttss ffo
orr
Te l e c o m m u n i c a t i o n s S p a c e I d e n t i f i c a t i o n
Section 5.1.1 States
A Telecommunications Space (TS) identifier, unique within the building, shall be assigned to the TS, and it shall
have the format fs, where:
f = numeric character(s) identifying the floor of the building occupied by the TS
s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located
For buildings with non-numeric floors, alpha-numeric characters may be used in the “f” format and shall be
consistent with the floor naming convention used within the building. The TS shall be labeled with the TS identifier
inside the room so as to be visible to someone working in that room.
For example:
“1A” = first floor, TS A
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can
be generated by a mechanical device and are made of durable polymer construction
that will withstand the effects of moisture, heat and time.
Telecommunications Spaces can be identified with the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number
C200X100FJJ
Part Description
White adhesive polyolefin labels
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1000 5000
*Order number of labels required in multiples of Std. Pkg. Qty.
PANAC–EA ™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
LS7-75NL-1
Part Description
Black/white non-laminated polyester label cassette
Height
in
mm
0.708
Length
ft
m
17.98 26.200
8.00
Std. Std.
Pkg. Ctn.
Qty.* Qty.
1
20
*Order number of cassettes required.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Number
C200X100FJ6
Part Description
White adhesive polyolefin labels, 500/roll
*Order number of rolls required.
8
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1
10
Telecommunications Main Grounding Busbar and
Grounding Busbar Identification
PANDUIT ®® Network
Network Labeling
Labeling Products
Products for
for Telecommunications
Telecommunications
PANDUIT
Main Grounding
Grounding Busbar
Busbar and
and Grounding
Grounding Busbar
Busbar
Main
Section 5.1.3 States
The Telecommunications Main Grounding Busbar (TMGB) identifier is used to identify the single TMGB present
in a building. The TMGB shall be labeled with the TMGB identifier. The format for the TMGB identifier shall be
“fs-TMGB”, where:
fs = TS (telecommunications space) identifier for the space containing the TMGB
TMGB = portion of an identifier designating a telecommunications main grounding busbar
For example:
“1A-TMGB” = first floor, TS A,
telecommunications main grounding busbar
Section 5.1.4 States
A Telecommunications Grounding Busbar (TGB) identifier is used to identify TGBs in the grounding and
bonding system. Each TGB shall be labeled with the TGB identifier. A unique TGB identifier shall be assigned
to each TGB and the format for the TGB identifier shall be “fs-TGB”, where
fs = TS identifier for the space containing the TGB
TGB = portion of an identifier designating a telecommunications grounding busbar
All of the TGB identifiers in a single infrastructure should have the same format where possible.
For example:
“1A-TGB” = first floor, TS A,
telecommunications grounding busbar
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers
can be generated by a mechanical device and are made of durable polymer
construction that will withstand the effects of moisture, heat and time.
Telecommunications (Main) Grounding Busbars can be identified with
the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Description
Part Number
C200X100FJJ
White adhesive polyolefin labels
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1000 5000
*Order number of labels required in multiples of Std. Pkg. Qty.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Description
Part Number
LS7-75NL-1
Black/white non-laminated polyester label cassette
Height
in
mm
0.708
Length
ft
m
17.98 26.200
8.00
Std. Std.
Pkg. Ctn.
Qty.* Qty.
1
20
*Order number of cassettes required.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Description
Part Number
C200X100FJ6
White adhesive polyolefin labels, 500/roll
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1
10
*Order number of rolls required.
9
For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory).
Horizontal Link Identification - IDC Punch Down Block
PA
PAN
ND
DU
UIIT
T ®® N e t w o r k L a b e l i n g P r o d u c t s f o r
IID
DC
C P
Pu
un
nch
ch D
Do
ow
wn
n B
Bllo
ock
ckss
Section 5.1.2 States
A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its
elements. In the TS (telecommunications space), each section of an IDC connector (punch-down block)
terminating a four-pair cable shall be labeled with the “an” portion of the identifier. This requirement may be met
by labeling an IDC connector or group of IDC connectors with the “a” portion of the identifier, and the section of
an IDC connector terminating a four-pair cable labeled with the “n” portion where:
a = one to two alpha characters uniquely identifying an IDC connector, or a group of IDC connectors,
serving as part of the horizontal cross-connect
n = two to four numeric characters designating the section of an IDC connector on which a four-pair
horizontal cable is terminated
For example:
“B04” = IDC block B, position 04
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers
can be generated by a mechanical device and are made of durable polymer
construction that will withstand the effects of moisture, heat and time.
IDC Punch Down Blocks can be identified with the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number
C750X050Y1J
Part Description
Punchdown block, white non-adhesive polyester labels
Width
in
mm
7.50
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
190.50 0.500
12.70
500
2500
*Order number of labels required in multiples of Std. Pkg. Qty.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
LS7-50-1
Part Description
Black/white laminated polyester label cassette
Height
in
mm
0.472
Length
ft
m
17.98 26.200
8.00
Std. Std.
Pkg. Ctn.
Qty.* Qty.
1
20
*Order number of cassettes required.
For non-adhesive labeling solutions, do not remove liner from label.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Number
C750X050Y16
Part Description
Punchdown block, white non-adhesive polyester labels, 50/roll
*Order number of rolls required.
For non-adhesive labeling solutions, do not remove liner from label.
10
Width
in
mm
7.50
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
190.50 0.500
12.70
1
10
Firestopping Location Identification
PA N D U I T ® N e t w o r k L a b e l i n g P r o d u c t s f o r F i r e s t o p p i n g
Locations
Section 6.1.3 States
A Firestopping Location (FSL) identifier shall identify each installation of firestopping material.
The format for the firestopping location identifier shall be “f-FSLn(h)”, where:
f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space)
FSL = an identifier referring to a firestopping location
n = two to four numeric characters identifying one firestopping location
h = one numeric character specifying the hour rating of the firestopping system
All firestopping location identifiers in a single infrastructure should have the same format where possible.
Each firestopping location shall be labeled at each location where firestopping is installed, on each side of the
penetrated fire barrier, within 300 mm (12 in) of the firestopping material.
For example:
“1-FSL01(2)” = first floor, firestopping location
number 01, two hour rating
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers
can be generated by a mechanical device and are made of durable polymer
construction that will withstand the effects of moisture, heat and time.
Firestopping Locations can be identified with the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number
C200X100FJJ
Part Description
White adhesive polyolefin labels
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1000 5000
*Order number of labels required in multiples of Std. Pkg. Qty.
PANAC–EA™ LS7 Hand-H
Held Thermal Transfer Printing Solution
Part Number
LS7-75NL-1
Part Description
Black/white non-laminated polyester label cassette
Height
in
mm
0.708
Length
ft
m
17.98 26.200
Std. Std.
Pkg. Ctn.
Qty.* Qty.
8.00
1
20
*Order number of cassettes required.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Number
C200X100FJ6
Part Description
White adhesive polyolefin labels, 500/roll
Width
in
mm
2.000
50.80
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
1.000
25.40
1
10
*Order number of rolls required.
11
For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory).
Horizontal Link Identification - Connector
PA N D U I T ® N e t w o r k L a b e l i n g P r o d u c t s f o r C o n n e c t o r s
Section 5.1.2 States
A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements.
In the work area, each individual telecommunications outlet/connector shall be labeled with the horizontal link
identifier. The labeling shall appear on the connector, faceplate, or MUTOA, in a way that clearly identifies the
individual connector associated with the particular identifier. A horizontal link identifier shall have a format of
“fs-an” where:
f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space)
s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located
a = one to two alpha characters uniquely identifying a single patch panel or a group of patch panels with
sequentially numbered ports, an IDC connector, or a group of IDC connectors, serving as part of the
horizontal cross-connect
n = two to four numeric characters designating the port on a patch panel in the TS or the section of an IDC
connector on which a four-pair horizontal cable is terminated in the TS.
For example:
“1A-B01” = origination point first floor,
TS A, patch panel B, position 01
PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can
be generated by a mechanical device and are made of durable polymer construction
that will withstand the effects of moisture, heat and time.
Horizontal Link Connectors can be identified with the following labels:
Desktop Laser / Ink Jet Printing Solution
Part Number
C138X019FJJ
Part Description
White adhesive polyolefin labels
Width
in
mm
1.380
35.05
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
0.190
4.83
2500 12500
*Order number of labels required in multiples of Std. Pkg. Qty.
VIPER ™ LS6 Portable Thermal Transfer Printing Solution
Part Number
C138X019FJ6
Part Description
White adhesive polyolefin labels, 500/roll
*Order number of rolls required.
12
Width
in
mm
1.380
35.05
Std. Std.
Height
Pkg. Ctn.
in
mm Qty.* Qty.
0.190
4.83
1
10
Portable Printers
PA N D U I T ® N e t w o r k L a b e l i n g S y s t e m s Po r t a b l e P r i n t e r s
Section 10.1 States
The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read.
Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels should
be resistant to the environmental conditions at the point of installation (such as moisture, heat or ultraviolet
light), and should have a design life equal to or greater than that of the labeled component.
Section 10.2 States
To maximize legibility, all labels shall be printed or generated by a mechanical device.
– EA™ LS7 Hand-Held Thermal Transfer Printer and the VIPER ™ LS6 Portable
The PANAC
Thermal Transfer Printer mechanically generate labels that are made of durable
polymer construction and will withstand the effects of moisture, heat and time.
–EA LS7 Hand-Held Thermal Transfer Printer
PANAC
• Multi-purpose printer supports ULTIMATE ID ™ and additional
network labeling requirements. For detailed printing
instructions, request SA-IDSP01
• High quality thermal transfer print for professional looking
labels that will not smear
• Fast loading label cassettes include both label material and
ribbon to make changing labels easy
Part Number
• No more spacing and guess work length function aligns
legends with ports
• Advanced functions including serialization, vertical and
horizontal lines, symbol library and memory
• Six AA alkaline batteries and hardside case included
• For a PANAC–EA LS7 full product line brochure, request
SA-IDCB1000A
Std. Pkg. Std. Ctn.
Qty*
Qty
Part Description
LS7
LS7 Hand-Held Thermal Transfer Printer Kit: Includes printer, 3/4" (18mm) non-laminated black/white
cassette, hardside carrying case, wrist strap, batteries, label separator tool and operator's manual
1
4
LS7-ACS^
120 VAC Adapter
1
6
LS7-CLN
Cleaning Cassette
1
20
*Order number required in multiples of Std. Pkg. Qty.
^Cannot be used to recharge batteries.
VIPER LS6 Portable Thermal Transfer Printer
• Create wiremarkers, heat shrink labels, continuous tape,
component labels, bin markers, pipe markers, safety/facility
identification and network connectivity labels
• High quality thermal transfer print for professional looking
labels that will not smear
• AC Adapter included so you can start printing right out of
the box
• Serial port/PC interfacing
• Fast loading ribbon cartridge lets you slide, lock and go!
Part Number
• 128 K file memory reduces setup time by recalling
frequently used labels
• Nickel Metal Hydride battery provides longer battery life
• Advanced functions including serialization, bar code
printing, vertical and horizontal lines, date and time stamp,
variety of font sizes and a symbol library containing over
40 electrical, safety and network symbols
• For a VIPER LS6 full product line brochure, request
SA-ID07BR01A
Part Description
Std. Pkg. Std. Ctn.
Qty*
Qty
1
—
LS6-KIT
Includes printer, LS6-RWBLK ribbon, battery pack, 120 VAC adapter/charger, hardside carrying case
and operator's manual
LS6-RWBLK
Wax Ribbon, Black, 2" x 100'. For use with self-laminating vinyl, heat shrink and vinyl cloth materials
1
6
LS6-RRBLK
Resin Ribbon, Black, 2" x 100'. For use with polyester, polyolefin and vinyl materials
1
6
LS6-RRWHT
Resin Ribbon, White, 2" x 75'. For use with clear and colored polyester and vinyl tape
1
6
LS6-BP
Replacement Battery Pack
1
—
LS6-ACS
Replacement 120 VAC Adapter/Charger
1
—
LS6-PCKIT
PC Interface Kit. Serial Cable and VIPERLINK
1
—
LS6-CLN
Package of 5 Printer Cleaning Cards
1
5
™
Software
*Order number required in multiples of Std. Pkg. Qty.
For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory).
13
Computer Printable Software
PA
PAN
ND
DU
UIIT
T ®® N e t w o r k L a b e l i n g S y s t e m s C o m p u t e r
P
Prriin
nttaab
bllee S
So
oft
ftw
waarree
Section 10.1 States
The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read.
Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels
should be resistant to the environmental conditions at the point of installation (such as moisture, heat or
ultraviolet light), and should have a design life equal to or greater than that of the labeled component.
Section 10.2 States
To maximize legibility, all labels shall be printed or generated by a mechanical device.
Laser/Ink Jet printers mechanically generate labels made of durable polymer
construction that will withstand the effects of moisture, heat and time.
ULTIMATE ID ™ Labeling Software For WINDOWS^
• Fast and easy creation of labels for ULTIMATE ID Network Labeling
System patch panels, faceplates, surface mount boxes and
marker ties
• Automatically aligns legends with ports on patch panels
and faceplates
• Create alpha and numeric serializations
• Import information from EXCEL^ and text files directly onto
the ULTIMATE ID label formats
• Image library includes commonly used symbols for fax,
data and voice
• Vertical line function enables users to separate legends
• Automatic font sizing
• On-line help function assists in understanding the TIA/EIA-606-A
standard to insure network labeling compliance
• Easy to install and supplied on CD-ROM
• Supports most WINDOWS printer drivers and is compatible with
standard desktop laser and ink jet printers
• For ULTIMATE ID Labeling Software full product line brochure,
request SA-IDCB11
System Requirements:
• WINDOWS 95, 98, Me, 2000, NT 4.x, and XP; minimum 486
processor; minimum 10MB of RAM; 30 MB hard drive space
Part Number
UISW
Part Description
Std.
Pkg.
Qty*
Std.
Ctn.
Qty
1
10
Std.
Pkg.
Qty*
Std.
Ctn.
Qty
1
10
Windows labeling software, CD-ROM
* Order number of software packages required.
PAN-MARK ® 2.5 for WINDOWS Labeling Software
• PAN-MARK for Windows Labeling Software has preloaded and
ready to use, thermal transfer, dot-matrix, laser and ink jet label
formats. For use with non-ULTIMATE ID labeling solutions
• ODBC (Open Data-Base Connectivity) allows importing of
information from electronic databases such as EXCEL and
ACCESS^ directly onto the label formats
• Easy to install and supplied on CD-ROM
• Uses a full range of WINDOWS fonts including TrueType† fonts
• Use image library to add commonly used symbols to your labels
(Fax, Data, Voice, etc.)
• Import Bitmap (.bmp) graphic images on to a label
• Create Alpha and numeric serializations
• For PAN-MARK for Windows full product line brochure,
request SA-IDCB1043A
System Requirements:
• WINDOWS 95, 98, Me, 2000, NT 4.x, and XP; minimum 486
processor; minimum 8MB of RAM; 30 MB hard drive space
Part Number
Part Description
PROG-WIN2CD Windows labeling software, CD-ROM
* Order number of software packages required.
14
^ WINDOWS, EXCEL and ACCESS are registered trademarks of Microsoft Corp.
†
TrueType is a registered trademark of Apple Computing, Inc.
Labeling Solutions for TIA/EIA-606-A
The TIA/EIA-606-A standard establishes guidelines for owners, end users, manufacturers, consultants,
contractors, designers, installers, and facilities administrators involved in the administration of the
telecommunications infrastructure.
Four classes of administration are specified in the standard, to accommodate diverse degrees of
complexity present in the telecommunications infrastructure. The specifications for each class include
requirements for identifiers, records, and labeling.
addresses the administration needs of a premises that is served by a single
telecommunications space (TS) containing its telecommunications equipment.
Required in class 1 administration are identifiers for the TS, any Telecommunications Main Grounding
Busbar, and all elements of the horizontal links.
Class 1
For a copper horizontal link, the elements include:
• the connecting hardware (e.g., patch panel port or the section of a punchdown block
terminating a four-pair horizontal cable)
• a four-pair horizontal cable
• a telecommunications outlet/connector terminating a four-pair horizontal cable in the work area
If a consolidation point (CP) is present:
• the segment of four-pair horizontal cable extending from the TS to the CP connecting hardware
• the CP connecting hardware or section of a punchdown block terminating a four-pair horizontal cable
• the segment of four-pair horizontal cable extending from the CP connecting hardware to the outlet/
connector of a multi-user telecommunications outlet assembly (MUTOA) or to the work area outlet
If a MUTOA is present:
• a telecommunications outlet/connector in the MUTOA
For an optical fiber horizontal link, the elements include:
• a pair of optical fiber terminations on a patch panel in the TS
• a pair of optical fibers in a cable
• a pair of optical fiber terminations in the work area
• a telecommunications outlet/connector terminating a pair of optical fibers in the work area
If a consolidation point (CP) is present:
• the segment of optical fiber cable extending from the TS to the CP connecting hardware.
• the CP connecting hardware or section terminating a pair of optical fibers
• the segment of optical fiber cable extending from the CP connecting hardware to the outlet/connector of
a multi-user telecommunications outlet assembly (MUTOA) or to the work area outlet.
administration provides for telecommunications infrastructure administration
needs of a single building or tenant that is served by a single or multiple TSs
within a single building. Class 2 administration includes all elements of class 1 administration, plus
identifiers for backbone cabling, multiple-element grounding and bonding systems, and firestopping.
Class 2
administration addresses the needs of a campus, including its buildings and
outside plant elements. Class 3 administration includes all elements of class 2
administration, plus identifiers for buildings and interbuilding cabling. Administration of pathways and
spaces, and of outside plant elements is recommended.
Class 3
administration addresses the needs of a multi-site system. Class 4
administration includes all elements of class 3 administration, plus an
identifier for each site, and optional identifiers for wide area network connections.
Class 4
15
PANDUIT Identification Products can assist you with all the labeling procedures required by this standard.
The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read.
Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels should
be resistant to the environmental conditions at the point of installation (such as moisture or heat), and should
have a design life equal to or greater than that of the labeled component. To maximize legibility, all labels shall
be printed or generated by a mechanical device. Panduit provides everything you need to comply with the
TIA/EIA-606-A standard for all of your structured cabling labeling requirements!
Horizontal Link Identifier Labeling Format
A horizontal link identifier shall have a format of fs-an where:
f = numeric character(s) identifying the floor of the building occupied
by the Telecommunications Space (TS)
Floor (1)
s = alpha character(s) uniquely identifying the TS on floor f, or the
Telecommunications
building area in which the space is located
Space (A)
a = one to two alpha characters uniquely identifying a single patch
panel, a group of patch panels with sequentially numbered ports,
Patch Panel ID (A)
an IDC connector, or a group of IDC connectors, serving as part
of the horizontal cross-connect
Port ID (004)
n = two to four numeric characters designating the port on a
panel in the TS, or the section of an IDC connector on which a
four pair horizontal cable is terminated in the TS
EXAMPLE- “1A-A004” = Origination Point 1st Floor, Closet A, Panel A, Position 004
Text
Clauses
Description of Identifier
fs
5.1.1
telecommunications space (TS)
R
R
R
R
fs-an
5.1.2
horizontal link
R
R
R
R
fs-TMGB
5.1.3
telecommunications main grounding busbar
R
R
R
R
fs-TGB
5.1.4
telecommunications grounding busbar
R
R
R
R
fs1 /fs2-n
6.1.1
building backbone cable
R
R
R
fs1 /fs2-n.d
6.1.2
building backbone pair of optical fiber
R
R
R
f-FSLn(h)
6.1.3
firestop location
R
R
R
[b1-fs1 ]/[b2-fs2 ]-n
7.1.2
campus backbone cable
R
R
[b1 -fs1 ]/[b2-fs2 ]-n.d
7.1.3
campus backbone pair of optical fiber
R
R
b
7.1.1
building
R
R
c
8.1.1
campus or site
1
4
R
fs-UUU.n.d(q)
annex B
intra-space pathway
O
O
O
fs1 /fs2-UUU.n.d(q)
annex B
building pathway
O
O
O
c-UUU.n.d(q)
annex B
outside plant pathway
O
O
[b1-fs1 ]/[b2 -fs2 ]-UUU.n.d(q)
annex B
campus pathway
O
O
[c1 -b1 -fs1 ]/[c2 -b2 -fs2 ]-UUU.n.d(q)
annex B
inter-campus element
R = required identifier for class, when corresponding element is present
O = optional identifier for class
16
Class of Administration
2
3
Identifier
O
NETWORK CONNECTIVITY GROUP
USA: Contact PANDUIT ® Corporate headquarters or visit our website at www.panduit.com/ncg for a listing of local
sales representatives in the USA. INTERNATIONAL: Call our regional Headquarters Offices or visit our website to
locate PANDUIT sales personnel and distributors in your area:
All PANDUIT PAN-NET ® non-consumable products have a 20 year warranty. When installed
per TIA/EIA or ISO/IEC standards, the PANDUIT PAN-NET System will operate the
application(s) which the system was designed to support. Applications may include, but
are not limited to: 10/100/1000 Mbps Ethernet (IEEE 802.3), 4/16 Mbps Token Ring (IEEE
802.5), 155/622/1.25 Gbps ATM, SONET, FDDI/CDDI and ISDN.
In order to qualify for the warranty, the system must be installed per the following: 1. Meet
all TIA/EIA commercial building wiring standards. 2. PANDUIT categorized product must
be used in conjunction with an equivalent or higher Category UL or ETL verified cable. 3.
PANDUIT products must be installed per appropriate PANDUIT instruction sheets. Note: All
networks shall be installed per applicable standards and manufacturer’s guidelines.
If any PANDUIT PAN-NET product fails to perform as stated above, PANDUIT will provide
new components at no charge. THIS WARRANTY IS MADE IN LIEU OF AND EXCLUDES
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY
EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or
damage, whether direct or consequential.
All PANDUIT electrical products are warranted to be free from defects in material and
workmanship at the time of sale but our obligation under this warranty is limited to the
replacement of any product proved to be defective within 6 months (for product) or 90
days (for tools) from the date of delivery. Tool warranty is void if PANDUIT tools are
modified, altered or misused in any way. Use of PANDUIT tooling with any product other
than the specified PANDUIT products for which the tool was designed, constitutes misuse.
Before using, user shall determine the suitability of the product for his intended use and
user assumes all risk and liability whatsoever in connection therewith.
This warranty is made in lieu of and excludes all other warranties, expressed or implied.
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
USE ARE SPECIFICALLY EXCLUDED. Neither seller nor manufacturer shall be liable for any
other injury, loss or damage, whether direct or consequential, arising out of the use of, or
the inability to use, the product. The information contained in this literature is based on our
experience to date and is believed to be reliable. It is intended as a guide for use by persons
having technical skill at their own discretion and risk. We do not guarantee favorable
results or assume any liability in connection with its use. Dimensions contained herein are
for reference purposes only. For specific dimensional requirements consult the factory.
This publication is not to be taken as a license to operate under, or a recommendation to
infringe any existing patents. This supersedes and voids all previous literature, etc.