® NET WORK CONNECTIVITY GROUP TIA/EIA-606-A LABELING COMPLIANCE BROCHURE (Featuring the PANDUIT ® ULTIMATE ID ™ Network Labeling System) TIA/EIA-606-A Labeling Compliance Brochure For compliance with the TIA/EIA-606-A standard, PANDUIT ® has the solution. This brochure will walk you through the labeling requirements of the standard and introduce you to identification solutions specifically designed to comply with TIA/EIA-606-A. The standard establishes guidelines for owners, end users, manufacturers, consultants, contractors, designers, installers, and facility administrators involved in the administration of the telecommunications infrastructure. Proper identification of your network allows moves, adds, changes, trouble shooting, and repairs to be accomplished faster and more efficiently. PANDUIT offers a full line of network connectivity products, labeling products, software, and printers to assist you with TIA/EIA-606-A compliance. The ULTIMATE ID ™ Network Labeling System featured in this brochure was designed specifically with the TIA/EIA-606-A standard in mind. It includes faceplates, surface mount boxes, patch panels, marker ties, labels for desktop printers, and the PANAC–EA ™ LS7 hand-held thermal transfer printer. All ULTIMATE ID hardware uses labels with a common compact height; this not only enhances the appearance of the installation, but also saves time and money by providing a clear and efficient way to label according to the TIA/EIA-606-A standard. All labels are positioned adjacent to, centered and parallel to the module they are identifying. The appearance of the installation can be further enhanced by using a consistent font size throughout the installation. The PANAC– EA LS7 printer and PANDUIT desktop labeling software can both be used to mechanically print labels with the same font. For detailed information on related PANDUIT identification products, request any of the following: • ULTIMATE ID Network Labeling System Catalog: SA-IDCB01 • PAN-CODE ™ Identification and Labeling Solution Products: SA101N315C • PANAC–EA LS7 Hand-Held Thermal Transfer Printer: SA-IDCB1000A • VIPER ™ LS6 Portable Thermal Transfer Printer: SA-ID07BR01A • ULTIMATE ID Labeling Software for WINDOWS^: SA-IDCB11 • PAN-MARK ™ 2.5 Labeling Software for WINDOWS: SA-IDCB1043A • Detailed printing instructions for ULTIMATE ID labels with the PANAC–EA LS7 Hand-Held Thermal Transfer Printer: SA-IDSP01 ^WINDOWS is a registered trademark of Microsoft Corp. Table of Contents Roadmaps 2-3 Horizontal Link Identification - Patch Panel 4 Horizontal Link Identification - Outlet 5 Cable Identification 6-7 Telecommunications Space Identification 8 Telecommunications Main Grounding Busbar and Grounding Busbar Identification 9 Horizontal Link Identification - IDC Punch Down Block 10 Firestopping Location Identification 11 Horizontal Link Identification - Connector 12 Portable Printers 13 Computer Printable Software 14 Overview of TIA/EIA-606-A 15 Horizontal Link Identifier Labeling Format 16 1 For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory). TIA/EIA-606-A Labeling Compliance in the Telecommunications Space Roadmap 2 7 6 3 1 6 5 4 2 1 Telecommunications Space Identification (see page 8) 5 Horizontal Link Identification — IDC Punch Down Block (see page 10) 2 Cable Identification — Backbone (see pages 6-7) 6 Cable Identification — Horizontal Link (see pages 6-7) 3 Telecommunications (Main) Grounding Busbar Identification (see page 9) 7 Firestopping Location Identification (see page 11) 4 Horizontal Link Identification — Patch Panel (see page 4) TIA/EIA-606-A Labeling Compliance in the Work Area Roadmap 6 9 6 Cable Identification — Horizontal Link (see pages 6-7) 8 Horizontal Link Identification — Outlet (see page 5) 9 Horizontal Link Identification — Connector (see page 12) 8 3 Horizontal Link Identification - Patch Panel U LT I M AT E I D ™™N e t w o r k L a b e l i n g S y s t e m f o r Pa t ch Pa n e l s Section 5.1.2 States A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements. In the Telecommunications Space (TS), each patch panel port shall be labeled with the “an” portion of the identifier. This requirement may be met by labeling a patch panel with the “a” portion of the identifier, and each port with the “n” portion where: a = one to two alpha characters uniquely identifying a single patch panel, or a group of patch panels with sequentially numbered ports n = two to four numeric characters designating the port on a patch panel in the TS For example: “A07” = patch panel A, position 07 The ULTIMATE ID patch panel and labeling system allows you to center the “an” identifier over each port. All ULTIMATE ID Patch Panels can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number UILJ4 Part Description Four port, white non-adhesive polyester labels, 66 labels per sheet Width in mm 2.585 65.65 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 0.236 5.99 5 50 *Order number of sheets required in multiples of Std. Pkg. Qty. For detailed information on ULTIMATE ID patch panels and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number UILS7BW Part Description Black/white non-laminated polyester label cassette Height in mm 0.236 5.99 Length ft m 26.200 8.00 Std. Std. Pkg. Ctn. Qty.* Qty. 1 20 *Order number of cassettes required. For non-adhesive labeling solutions, do not remove liner from the label. Patch panels which are not part of the ULTIMATE ID Network Labeling System can be identified by utilizing the LS7-25-1 label cassette as –EA LS7 full line product bulletin, request SA-IDCB1000A. an adhesive label. For a PANAC 4 Horizontal Link Identification - Outlet U LT I M AT E I D ™™ N e t w o r k L a b e l i n g S y s t e m f o r O u t l e t s ( F a c e p l a t e s / S u r f a c e M o u n t B o xe s ) Section 5.1.2 States A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements. In the work area, each individual telecommunications outlet/connector shall be labeled with the horizontal link identifier. The labeling shall appear on the connector, faceplate, or MUTOA, in a way that clearly identifies the individual connector associated with the particular identifier. A horizontal link identifier shall have a format of “fs-an” where: f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space) s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located a = one to two alpha characters uniquely identifying a single patch panel or a group of patch panels with sequentially numbered ports, an IDC connector, or a group of IDC connectors, serving as part of the horizontal cross-connect n = two to four numeric characters designating the port on a patch panel in the TS or the section of an IDC connector on which, a four-pair horizontal cable is terminated in the TS For example: “1A-B02” = origination point first floor, TS A, patch panel B, position 02 Each ULTIMATE ID faceplate/surface mount box is designed in a way that allows you to center the “an” identifier clearly over each connector, while the “fs” identifier can be placed in the station space. All ULTIMATE ID Faceplates/Surface Mount Boxes can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number** Width in mm Part Description Height in mm Std. Std. Pkg. Ctn. Qty.* Qty. UILJ1 One port label, white non-adhesive polyester labels, 264 labels per sheet 0.680 17.27 0.236 5.99 5 50 UILJ2 Two port labels, white non-adhesive polyester labels, 132 labels per sheet 1.315 33.40 0.236 5.99 5 50 UILJ3 Three port labels, white non-adhesive polyester labels, 99 labels per sheet 1.950 49.53 0.236 5.99 5 50 UILJ4 Four port labels, white non-adhesive polyester labels, 66 labels per sheet 2.585 65.66 0.236 5.99 5 50 UILJ6 Six port labels, white non-adhesive polyester labels, 66 labels per sheet Label sheets with 40-one port, 60-two port, 3-three port and 24-four port labels per sheet, white non-adhesive polyester 3.855 97.92 0.236 5.99 5 50 — — 0.236 5.99 5 50 UILJCOMBO *Order number of sheets required in multiples of Std. Pkg. Qty. **For Electrical Ivory labels, add EI at end of part number. For detailed information on ULTIMATE ID faceplates and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number UILS7BW Part Description Black/white non-laminated polyester label cassette Height in mm 0.236 5.99 Length ft m 26.200 Std. Std. Pkg. Ctn. Qty.* Qty. 8.00 1 20 *Order number of cassettes required. For non-adhesive labeling solutions, do not remove liner from the label. Faceplates which are not part of the ULTIMATE ID Network Labeling System can be identified by utilizing the LS7-25-1 label cassette as an adhesive label. Non-ULTIMATE ID faceplates which accept 0.4 inch high labels can be identified by utilizing the LS7-38-1 label cassette as a non-adhesive label. For a PANAC–EA LS7 full line product bulletin, request SA-IDCB1000A. For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory). 5 Cable Identification PA N D U I T ®® C a b l e I d e n t i f i c a t i o n P r o d u c t s Section 5.1.2 States A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements. Each end of a horizontal cable shall be labeled within 300 mm (12 in) of the end of the cable jacket with the horizontal link identifier, which shall be visible on the exposed part of the cable jacket. This shall include each cable in the Telecommunications Space (TS), at the work area, and at a Consolidation Point (CP), if present. A horizontal link identifier shall have a format of “fs-an” where: f= s= a= n= numeric character(s) identifying the floor of the building occupied by the TS alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located one to two alpha characters uniquely identifying a single patch panel or a group of patch panels with sequentially numbered ports, an IDC connector, or a group of IDC connectors serving as part of the horizontal cross-connect two to four numeric characters designating the port on a patch panel in the TS or the section of an IDC Connector on which a four pair horizontal cable is terminated in the TS For example: “1A-B01” = cable origination point first floor, TS A, patch panel B, position 01 ULTIMATE ID ™ Solution UILJ2 Label and UICBM1M Marker Tie Non-ULTIMATE ID Solutions S100X150FAJ Self-Laminating Label S100X160FAJ Self-Laminating Label and NWSLC-3 Sleeve Section 6.1.1 States A unique building backbone cable identifier shall be assigned to each backbone cable between two TSs in one building and it shall have a format of “fs1/fs2-n” where: fs1 = TS identifier for the space containing the termination of one end of the backbone cable fs2 = TS identifier for the space containing the termination of the other end of the backbone cable n = one to two alphanumeric characters identifying a single cable with one end terminated in the TS designated fs1 and the other end terminated in the TS designated fs2 In this format, the TS with the lesser alphanumeric identifier shall be listed first. If the entire cable is within one TS, the format may be fs1/fs1-n. All building backbone cable identifiers in a single infrastructure should have the same format where possible. The backbone cable identifier shall be marked on each end of the backbone cable within 300 mm (12 in) of the end of the cable jacket. Ultimate ID Solution Non-ULTIMATE ID Solution For example: “1A/2A-1” = TS A on first floor to TS A on second floor, cable 1 UILJ2 Label and UIHL12-X0 or UIHL22X0 Marker Tie LS7-75NL-1 Label Cassette PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. 6 Cables and Cable Bundles can be identified with the following labels: ULTIMATE ID ™ Network Labeling System Solutions Desktop Laser / Ink Jet Printing Solution Part Number UILJ2** Width in mm Part Description Two port labels, non-adhesive white polyester labels, 132 labels per sheet 1.315 33.40 Height in mm 0.236 5.99 Std. Std. Pkg. Ctn. Qty.* Qty. 5 50 *Order number of sheets required in multiples of Std. Pkg. Qty. **For Electrical Ivory labels, add EI at end of part number. For use with UICM1M-C, UIHL12-XO and UIJL22-XO ULTIMATE ID Marker Ties to mark cables and bundles up to 1 inch in diameter. For detailed information on ULTIMATE ID patch panels and labeling solutions, request the ULTIMATE ID catalog, SA-IDCB01. PANAC–EA ™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number UILS7BW Height in mm Part Description 0.236 Black/white non-laminated polyester label cassette 5.99 Length ft m 26.200 8.00 Std. Std. Pkg. Ctn. Qty.* Qty. 1 20 *Order number of cassettes required. For non-adhesive labeling solutions, do not remove liner from the label. NON-ULTIMATE ID Network Labeling System Solutions Desktop Laser / Ink Jet Printing Solution Part Number Width in mm Part Description Length in mm Print-O On Min. Cable Max. Cable Std. Std. Height Diameter Diameter Pkg. Ctn. in mm in mm in mm Qty.* Qty. S100X150FAJ White self-laminating polyolefin labels 1.000 25.40 1.500 38.10 0.50 12.70 0.16 4.04 0.32 8.09 2500 12500 S100X160FAJ^ White self-laminating polyolefin labels 1.000 25.40 1.600 40.64 0.80 20.32 0.25 6.47 0.25 6.47 2500 12500 S100X225FAJ† White self-laminating polyolefin labels 1.000 25.40 2.250 57.15 0.75 19.05 0.24 6.07 0.48 12.13 1000 5000 *Order number of labels required in multiples of Std. Pkg. Qty. ^Use this label with NWSLC-2 LABELCORE ™ to identify 2 mm fiber, and with NWSLC-3 LABELCORE to identify 3 mm fiber. †Use this label with NWSLC-7 LABELCORE to identify 3 mm duplex fiber. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number Width in mm Part Description Length ft m Std. Std. Pkg. Ctn. Qty.* Qty. LS7-75NL-1^ Black/white non-laminated polyester label cassette 0.708 17.98 26.200 8.00 1 20 LS7-75NL-2^ Black/clear non-laminated polyester label cassette 0.708 17.98 26.200 8.00 1 20 *Order number of cassettes required. ^Use these labels with NWSLC LABELCORE sleeves to identify fiber. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Number Width in mm Part Description Length in mm Print-O On Min. Cable Max. Cable Std. Std. Height Diameter Diameter Pkg. Ctn. in mm in mm in mm Qty.* Qty. 1 White self-laminating polyolefin labels, 250/roll 1.000 25.40 1.500 38.10 0.50 12.70 0.16 4.04 0.32 8.09 S100X160FA6^ White self-laminating polyolefin labels, 250/roll 1.000 25.40 1.600 40.64 0.80 20.32 0.25 6.47 0.25 6.47 1 10 S100X225FA6† White self-laminating polyolefin labels, 150/roll 1.000 25.40 2.250 57.15 0.75 19.05 0.24 6.07 0.48 12.13 1 10 S100X150FA6 10 *Order number of rolls required. ^Use this label with NWSLC-2 LABELCORE to identify 2mm fiber, and with NWSLC-3 LABELCORE to identify 3mm fiber. †Use this label with NWSLC-7 LABELCORE to identify 3mm duplex fiber. LABELCORE Fiber Optic Cable Identification System Apply LABELCORE Sleeve to cable Part Number NWSLC-2 NWSLC-3 NWSLC-7 Wrap label around LABELCORE Sleeve Part Description Cable identification sleeve, 2mm fiber cable, yellow Cable identification sleeve, 3mm fiber cable, orange Cable identification sleeve, 3mm duplex fiber cable, white Std. Pkg. Std. Ctn. Qty* Qty 100 100 100 1000 1000 1000 *Order number of sleeves required in multiples of Std. Pkg. Qty. Locate on straight section of cable at least 2" from fiber boot. For Technical Assistance, Call:866-405-6654 (Outside the U.S., see back cover for Regional Directory). 7 Telecommunications Space Identification PA N D U I T ®® N Neettw wo orrk k LL aab beelliin ng g P Prro od du uccttss ffo orr Te l e c o m m u n i c a t i o n s S p a c e I d e n t i f i c a t i o n Section 5.1.1 States A Telecommunications Space (TS) identifier, unique within the building, shall be assigned to the TS, and it shall have the format fs, where: f = numeric character(s) identifying the floor of the building occupied by the TS s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located For buildings with non-numeric floors, alpha-numeric characters may be used in the “f” format and shall be consistent with the floor naming convention used within the building. The TS shall be labeled with the TS identifier inside the room so as to be visible to someone working in that room. For example: “1A” = first floor, TS A PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. Telecommunications Spaces can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number C200X100FJJ Part Description White adhesive polyolefin labels Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1000 5000 *Order number of labels required in multiples of Std. Pkg. Qty. PANAC–EA ™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number LS7-75NL-1 Part Description Black/white non-laminated polyester label cassette Height in mm 0.708 Length ft m 17.98 26.200 8.00 Std. Std. Pkg. Ctn. Qty.* Qty. 1 20 *Order number of cassettes required. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Number C200X100FJ6 Part Description White adhesive polyolefin labels, 500/roll *Order number of rolls required. 8 Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1 10 Telecommunications Main Grounding Busbar and Grounding Busbar Identification PANDUIT ®® Network Network Labeling Labeling Products Products for for Telecommunications Telecommunications PANDUIT Main Grounding Grounding Busbar Busbar and and Grounding Grounding Busbar Busbar Main Section 5.1.3 States The Telecommunications Main Grounding Busbar (TMGB) identifier is used to identify the single TMGB present in a building. The TMGB shall be labeled with the TMGB identifier. The format for the TMGB identifier shall be “fs-TMGB”, where: fs = TS (telecommunications space) identifier for the space containing the TMGB TMGB = portion of an identifier designating a telecommunications main grounding busbar For example: “1A-TMGB” = first floor, TS A, telecommunications main grounding busbar Section 5.1.4 States A Telecommunications Grounding Busbar (TGB) identifier is used to identify TGBs in the grounding and bonding system. Each TGB shall be labeled with the TGB identifier. A unique TGB identifier shall be assigned to each TGB and the format for the TGB identifier shall be “fs-TGB”, where fs = TS identifier for the space containing the TGB TGB = portion of an identifier designating a telecommunications grounding busbar All of the TGB identifiers in a single infrastructure should have the same format where possible. For example: “1A-TGB” = first floor, TS A, telecommunications grounding busbar PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. Telecommunications (Main) Grounding Busbars can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Description Part Number C200X100FJJ White adhesive polyolefin labels Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1000 5000 *Order number of labels required in multiples of Std. Pkg. Qty. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Description Part Number LS7-75NL-1 Black/white non-laminated polyester label cassette Height in mm 0.708 Length ft m 17.98 26.200 8.00 Std. Std. Pkg. Ctn. Qty.* Qty. 1 20 *Order number of cassettes required. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Description Part Number C200X100FJ6 White adhesive polyolefin labels, 500/roll Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1 10 *Order number of rolls required. 9 For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory). Horizontal Link Identification - IDC Punch Down Block PA PAN ND DU UIIT T ®® N e t w o r k L a b e l i n g P r o d u c t s f o r IID DC C P Pu un nch ch D Do ow wn n B Bllo ock ckss Section 5.1.2 States A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements. In the TS (telecommunications space), each section of an IDC connector (punch-down block) terminating a four-pair cable shall be labeled with the “an” portion of the identifier. This requirement may be met by labeling an IDC connector or group of IDC connectors with the “a” portion of the identifier, and the section of an IDC connector terminating a four-pair cable labeled with the “n” portion where: a = one to two alpha characters uniquely identifying an IDC connector, or a group of IDC connectors, serving as part of the horizontal cross-connect n = two to four numeric characters designating the section of an IDC connector on which a four-pair horizontal cable is terminated For example: “B04” = IDC block B, position 04 PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. IDC Punch Down Blocks can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number C750X050Y1J Part Description Punchdown block, white non-adhesive polyester labels Width in mm 7.50 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 190.50 0.500 12.70 500 2500 *Order number of labels required in multiples of Std. Pkg. Qty. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number LS7-50-1 Part Description Black/white laminated polyester label cassette Height in mm 0.472 Length ft m 17.98 26.200 8.00 Std. Std. Pkg. Ctn. Qty.* Qty. 1 20 *Order number of cassettes required. For non-adhesive labeling solutions, do not remove liner from label. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Number C750X050Y16 Part Description Punchdown block, white non-adhesive polyester labels, 50/roll *Order number of rolls required. For non-adhesive labeling solutions, do not remove liner from label. 10 Width in mm 7.50 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 190.50 0.500 12.70 1 10 Firestopping Location Identification PA N D U I T ® N e t w o r k L a b e l i n g P r o d u c t s f o r F i r e s t o p p i n g Locations Section 6.1.3 States A Firestopping Location (FSL) identifier shall identify each installation of firestopping material. The format for the firestopping location identifier shall be “f-FSLn(h)”, where: f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space) FSL = an identifier referring to a firestopping location n = two to four numeric characters identifying one firestopping location h = one numeric character specifying the hour rating of the firestopping system All firestopping location identifiers in a single infrastructure should have the same format where possible. Each firestopping location shall be labeled at each location where firestopping is installed, on each side of the penetrated fire barrier, within 300 mm (12 in) of the firestopping material. For example: “1-FSL01(2)” = first floor, firestopping location number 01, two hour rating PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. Firestopping Locations can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number C200X100FJJ Part Description White adhesive polyolefin labels Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1000 5000 *Order number of labels required in multiples of Std. Pkg. Qty. PANAC–EA™ LS7 Hand-H Held Thermal Transfer Printing Solution Part Number LS7-75NL-1 Part Description Black/white non-laminated polyester label cassette Height in mm 0.708 Length ft m 17.98 26.200 Std. Std. Pkg. Ctn. Qty.* Qty. 8.00 1 20 *Order number of cassettes required. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Number C200X100FJ6 Part Description White adhesive polyolefin labels, 500/roll Width in mm 2.000 50.80 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 1.000 25.40 1 10 *Order number of rolls required. 11 For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory). Horizontal Link Identification - Connector PA N D U I T ® N e t w o r k L a b e l i n g P r o d u c t s f o r C o n n e c t o r s Section 5.1.2 States A horizontal link identifier, unique within the building, shall be assigned to each horizontal link and to its elements. In the work area, each individual telecommunications outlet/connector shall be labeled with the horizontal link identifier. The labeling shall appear on the connector, faceplate, or MUTOA, in a way that clearly identifies the individual connector associated with the particular identifier. A horizontal link identifier shall have a format of “fs-an” where: f = numeric character(s) identifying the floor of the building occupied by the TS (telecommunications space) s = alpha character(s) uniquely identifying the TS on floor f, or the building area in which the space is located a = one to two alpha characters uniquely identifying a single patch panel or a group of patch panels with sequentially numbered ports, an IDC connector, or a group of IDC connectors, serving as part of the horizontal cross-connect n = two to four numeric characters designating the port on a patch panel in the TS or the section of an IDC connector on which a four-pair horizontal cable is terminated in the TS. For example: “1A-B01” = origination point first floor, TS A, patch panel B, position 01 PANDUIT labels for laser/ink jet printers and hand-held thermal transfer printers can be generated by a mechanical device and are made of durable polymer construction that will withstand the effects of moisture, heat and time. Horizontal Link Connectors can be identified with the following labels: Desktop Laser / Ink Jet Printing Solution Part Number C138X019FJJ Part Description White adhesive polyolefin labels Width in mm 1.380 35.05 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 0.190 4.83 2500 12500 *Order number of labels required in multiples of Std. Pkg. Qty. VIPER ™ LS6 Portable Thermal Transfer Printing Solution Part Number C138X019FJ6 Part Description White adhesive polyolefin labels, 500/roll *Order number of rolls required. 12 Width in mm 1.380 35.05 Std. Std. Height Pkg. Ctn. in mm Qty.* Qty. 0.190 4.83 1 10 Portable Printers PA N D U I T ® N e t w o r k L a b e l i n g S y s t e m s Po r t a b l e P r i n t e r s Section 10.1 States The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read. Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels should be resistant to the environmental conditions at the point of installation (such as moisture, heat or ultraviolet light), and should have a design life equal to or greater than that of the labeled component. Section 10.2 States To maximize legibility, all labels shall be printed or generated by a mechanical device. – EA™ LS7 Hand-Held Thermal Transfer Printer and the VIPER ™ LS6 Portable The PANAC Thermal Transfer Printer mechanically generate labels that are made of durable polymer construction and will withstand the effects of moisture, heat and time. –EA LS7 Hand-Held Thermal Transfer Printer PANAC • Multi-purpose printer supports ULTIMATE ID ™ and additional network labeling requirements. For detailed printing instructions, request SA-IDSP01 • High quality thermal transfer print for professional looking labels that will not smear • Fast loading label cassettes include both label material and ribbon to make changing labels easy Part Number • No more spacing and guess work length function aligns legends with ports • Advanced functions including serialization, vertical and horizontal lines, symbol library and memory • Six AA alkaline batteries and hardside case included • For a PANAC–EA LS7 full product line brochure, request SA-IDCB1000A Std. Pkg. Std. Ctn. Qty* Qty Part Description LS7 LS7 Hand-Held Thermal Transfer Printer Kit: Includes printer, 3/4" (18mm) non-laminated black/white cassette, hardside carrying case, wrist strap, batteries, label separator tool and operator's manual 1 4 LS7-ACS^ 120 VAC Adapter 1 6 LS7-CLN Cleaning Cassette 1 20 *Order number required in multiples of Std. Pkg. Qty. ^Cannot be used to recharge batteries. VIPER LS6 Portable Thermal Transfer Printer • Create wiremarkers, heat shrink labels, continuous tape, component labels, bin markers, pipe markers, safety/facility identification and network connectivity labels • High quality thermal transfer print for professional looking labels that will not smear • AC Adapter included so you can start printing right out of the box • Serial port/PC interfacing • Fast loading ribbon cartridge lets you slide, lock and go! Part Number • 128 K file memory reduces setup time by recalling frequently used labels • Nickel Metal Hydride battery provides longer battery life • Advanced functions including serialization, bar code printing, vertical and horizontal lines, date and time stamp, variety of font sizes and a symbol library containing over 40 electrical, safety and network symbols • For a VIPER LS6 full product line brochure, request SA-ID07BR01A Part Description Std. Pkg. Std. Ctn. Qty* Qty 1 — LS6-KIT Includes printer, LS6-RWBLK ribbon, battery pack, 120 VAC adapter/charger, hardside carrying case and operator's manual LS6-RWBLK Wax Ribbon, Black, 2" x 100'. For use with self-laminating vinyl, heat shrink and vinyl cloth materials 1 6 LS6-RRBLK Resin Ribbon, Black, 2" x 100'. For use with polyester, polyolefin and vinyl materials 1 6 LS6-RRWHT Resin Ribbon, White, 2" x 75'. For use with clear and colored polyester and vinyl tape 1 6 LS6-BP Replacement Battery Pack 1 — LS6-ACS Replacement 120 VAC Adapter/Charger 1 — LS6-PCKIT PC Interface Kit. Serial Cable and VIPERLINK 1 — LS6-CLN Package of 5 Printer Cleaning Cards 1 5 ™ Software *Order number required in multiples of Std. Pkg. Qty. For Technical Assistance, Call: 866-405-6654 (Outside the U.S., see back cover for Regional Directory). 13 Computer Printable Software PA PAN ND DU UIIT T ®® N e t w o r k L a b e l i n g S y s t e m s C o m p u t e r P Prriin nttaab bllee S So oft ftw waarree Section 10.1 States The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read. Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels should be resistant to the environmental conditions at the point of installation (such as moisture, heat or ultraviolet light), and should have a design life equal to or greater than that of the labeled component. Section 10.2 States To maximize legibility, all labels shall be printed or generated by a mechanical device. Laser/Ink Jet printers mechanically generate labels made of durable polymer construction that will withstand the effects of moisture, heat and time. ULTIMATE ID ™ Labeling Software For WINDOWS^ • Fast and easy creation of labels for ULTIMATE ID Network Labeling System patch panels, faceplates, surface mount boxes and marker ties • Automatically aligns legends with ports on patch panels and faceplates • Create alpha and numeric serializations • Import information from EXCEL^ and text files directly onto the ULTIMATE ID label formats • Image library includes commonly used symbols for fax, data and voice • Vertical line function enables users to separate legends • Automatic font sizing • On-line help function assists in understanding the TIA/EIA-606-A standard to insure network labeling compliance • Easy to install and supplied on CD-ROM • Supports most WINDOWS printer drivers and is compatible with standard desktop laser and ink jet printers • For ULTIMATE ID Labeling Software full product line brochure, request SA-IDCB11 System Requirements: • WINDOWS 95, 98, Me, 2000, NT 4.x, and XP; minimum 486 processor; minimum 10MB of RAM; 30 MB hard drive space Part Number UISW Part Description Std. Pkg. Qty* Std. Ctn. Qty 1 10 Std. Pkg. Qty* Std. Ctn. Qty 1 10 Windows labeling software, CD-ROM * Order number of software packages required. PAN-MARK ® 2.5 for WINDOWS Labeling Software • PAN-MARK for Windows Labeling Software has preloaded and ready to use, thermal transfer, dot-matrix, laser and ink jet label formats. For use with non-ULTIMATE ID labeling solutions • ODBC (Open Data-Base Connectivity) allows importing of information from electronic databases such as EXCEL and ACCESS^ directly onto the label formats • Easy to install and supplied on CD-ROM • Uses a full range of WINDOWS fonts including TrueType† fonts • Use image library to add commonly used symbols to your labels (Fax, Data, Voice, etc.) • Import Bitmap (.bmp) graphic images on to a label • Create Alpha and numeric serializations • For PAN-MARK for Windows full product line brochure, request SA-IDCB1043A System Requirements: • WINDOWS 95, 98, Me, 2000, NT 4.x, and XP; minimum 486 processor; minimum 8MB of RAM; 30 MB hard drive space Part Number Part Description PROG-WIN2CD Windows labeling software, CD-ROM * Order number of software packages required. 14 ^ WINDOWS, EXCEL and ACCESS are registered trademarks of Microsoft Corp. † TrueType is a registered trademark of Apple Computing, Inc. Labeling Solutions for TIA/EIA-606-A The TIA/EIA-606-A standard establishes guidelines for owners, end users, manufacturers, consultants, contractors, designers, installers, and facilities administrators involved in the administration of the telecommunications infrastructure. Four classes of administration are specified in the standard, to accommodate diverse degrees of complexity present in the telecommunications infrastructure. The specifications for each class include requirements for identifiers, records, and labeling. addresses the administration needs of a premises that is served by a single telecommunications space (TS) containing its telecommunications equipment. Required in class 1 administration are identifiers for the TS, any Telecommunications Main Grounding Busbar, and all elements of the horizontal links. Class 1 For a copper horizontal link, the elements include: • the connecting hardware (e.g., patch panel port or the section of a punchdown block terminating a four-pair horizontal cable) • a four-pair horizontal cable • a telecommunications outlet/connector terminating a four-pair horizontal cable in the work area If a consolidation point (CP) is present: • the segment of four-pair horizontal cable extending from the TS to the CP connecting hardware • the CP connecting hardware or section of a punchdown block terminating a four-pair horizontal cable • the segment of four-pair horizontal cable extending from the CP connecting hardware to the outlet/ connector of a multi-user telecommunications outlet assembly (MUTOA) or to the work area outlet If a MUTOA is present: • a telecommunications outlet/connector in the MUTOA For an optical fiber horizontal link, the elements include: • a pair of optical fiber terminations on a patch panel in the TS • a pair of optical fibers in a cable • a pair of optical fiber terminations in the work area • a telecommunications outlet/connector terminating a pair of optical fibers in the work area If a consolidation point (CP) is present: • the segment of optical fiber cable extending from the TS to the CP connecting hardware. • the CP connecting hardware or section terminating a pair of optical fibers • the segment of optical fiber cable extending from the CP connecting hardware to the outlet/connector of a multi-user telecommunications outlet assembly (MUTOA) or to the work area outlet. administration provides for telecommunications infrastructure administration needs of a single building or tenant that is served by a single or multiple TSs within a single building. Class 2 administration includes all elements of class 1 administration, plus identifiers for backbone cabling, multiple-element grounding and bonding systems, and firestopping. Class 2 administration addresses the needs of a campus, including its buildings and outside plant elements. Class 3 administration includes all elements of class 2 administration, plus identifiers for buildings and interbuilding cabling. Administration of pathways and spaces, and of outside plant elements is recommended. Class 3 administration addresses the needs of a multi-site system. Class 4 administration includes all elements of class 3 administration, plus an identifier for each site, and optional identifiers for wide area network connections. Class 4 15 PANDUIT Identification Products can assist you with all the labeling procedures required by this standard. The size, color, and contrast of all labels should be selected to ensure that the identifiers are easily read. Labels should be visible during the installation of and normal maintenance of the infrastructure. Labels should be resistant to the environmental conditions at the point of installation (such as moisture or heat), and should have a design life equal to or greater than that of the labeled component. To maximize legibility, all labels shall be printed or generated by a mechanical device. Panduit provides everything you need to comply with the TIA/EIA-606-A standard for all of your structured cabling labeling requirements! Horizontal Link Identifier Labeling Format A horizontal link identifier shall have a format of fs-an where: f = numeric character(s) identifying the floor of the building occupied by the Telecommunications Space (TS) Floor (1) s = alpha character(s) uniquely identifying the TS on floor f, or the Telecommunications building area in which the space is located Space (A) a = one to two alpha characters uniquely identifying a single patch panel, a group of patch panels with sequentially numbered ports, Patch Panel ID (A) an IDC connector, or a group of IDC connectors, serving as part of the horizontal cross-connect Port ID (004) n = two to four numeric characters designating the port on a panel in the TS, or the section of an IDC connector on which a four pair horizontal cable is terminated in the TS EXAMPLE- “1A-A004” = Origination Point 1st Floor, Closet A, Panel A, Position 004 Text Clauses Description of Identifier fs 5.1.1 telecommunications space (TS) R R R R fs-an 5.1.2 horizontal link R R R R fs-TMGB 5.1.3 telecommunications main grounding busbar R R R R fs-TGB 5.1.4 telecommunications grounding busbar R R R R fs1 /fs2-n 6.1.1 building backbone cable R R R fs1 /fs2-n.d 6.1.2 building backbone pair of optical fiber R R R f-FSLn(h) 6.1.3 firestop location R R R [b1-fs1 ]/[b2-fs2 ]-n 7.1.2 campus backbone cable R R [b1 -fs1 ]/[b2-fs2 ]-n.d 7.1.3 campus backbone pair of optical fiber R R b 7.1.1 building R R c 8.1.1 campus or site 1 4 R fs-UUU.n.d(q) annex B intra-space pathway O O O fs1 /fs2-UUU.n.d(q) annex B building pathway O O O c-UUU.n.d(q) annex B outside plant pathway O O [b1-fs1 ]/[b2 -fs2 ]-UUU.n.d(q) annex B campus pathway O O [c1 -b1 -fs1 ]/[c2 -b2 -fs2 ]-UUU.n.d(q) annex B inter-campus element R = required identifier for class, when corresponding element is present O = optional identifier for class 16 Class of Administration 2 3 Identifier O NETWORK CONNECTIVITY GROUP USA: Contact PANDUIT ® Corporate headquarters or visit our website at www.panduit.com/ncg for a listing of local sales representatives in the USA. INTERNATIONAL: Call our regional Headquarters Offices or visit our website to locate PANDUIT sales personnel and distributors in your area: All PANDUIT PAN-NET ® non-consumable products have a 20 year warranty. When installed per TIA/EIA or ISO/IEC standards, the PANDUIT PAN-NET System will operate the application(s) which the system was designed to support. Applications may include, but are not limited to: 10/100/1000 Mbps Ethernet (IEEE 802.3), 4/16 Mbps Token Ring (IEEE 802.5), 155/622/1.25 Gbps ATM, SONET, FDDI/CDDI and ISDN. In order to qualify for the warranty, the system must be installed per the following: 1. Meet all TIA/EIA commercial building wiring standards. 2. PANDUIT categorized product must be used in conjunction with an equivalent or higher Category UL or ETL verified cable. 3. PANDUIT products must be installed per appropriate PANDUIT instruction sheets. Note: All networks shall be installed per applicable standards and manufacturer’s guidelines. If any PANDUIT PAN-NET product fails to perform as stated above, PANDUIT will provide new components at no charge. THIS WARRANTY IS MADE IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or damage, whether direct or consequential. All PANDUIT electrical products are warranted to be free from defects in material and workmanship at the time of sale but our obligation under this warranty is limited to the replacement of any product proved to be defective within 6 months (for product) or 90 days (for tools) from the date of delivery. Tool warranty is void if PANDUIT tools are modified, altered or misused in any way. Use of PANDUIT tooling with any product other than the specified PANDUIT products for which the tool was designed, constitutes misuse. Before using, user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith. This warranty is made in lieu of and excludes all other warranties, expressed or implied. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or damage, whether direct or consequential, arising out of the use of, or the inability to use, the product. The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult the factory. This publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc.