Dry Type 600 Volts and Below Single Phase Class 7400 Single Phase – General Purpose Transformers Single Phase – Export Model Transformers General purpose standard transformers are intended for power, heating, lighting, and light-duty control applications. See page 12-4 or contact your nearest Square D/Schneider Electric sales office for voltages not listed below. These general-purpose transformers are designed to accommodate voltage systems worldwide. kVA Catalog Number q Price Full Capacity Taps Degree C Weightk Enclosure Temp. Rise (Pounds) ck Single Phase – 240 X 480 V Primary 120/240 V Secondary 60 Hz UL Listed through 167 kVA cUL Listed through 10 kVA .050 .100 .150 .250 .500 50SV1A 100SV1A 150SV1A 250SV1B 500SV1B .750 1 1.5 2 3 750SV1F 1S1F 1.5S1F 2S1F 3S1F $ 87. 102. 121. 129. 184. None None None None None 55 55 55 80 80 4.2 4.5 6.2 10.5 13.8 1A 2A 3A 4A 5A 219. 287. 345. 427. 545. None None None None None 115 115 115 115 115 15.5 21.2 30.1 39.1 60 6A 7A 8A 9A 10A Export model transformers 10 kVA and smaller, certified by TUV (file no. E9571881.01) to meet EN60-742, are CE marked in addition to being UL and cUL Listed. For CE marked transformers in other ratings, see pages 12-12 through 12-16 in this Digest. Or contact your nearest Square D/Schneider Electric sales office for CE marked transformers up to 300 kVA, single and three phase. See page 12-9 for optional Fingersafe terminal block cover kit. Single Phase – 190/200/208/220 X 380/400/416/440 5 7.5 10 15 15 25 5S1F 7S1F 10S1F 15S1F 15S1H 25S3H 741. 1042. 1291. 2586. 1731. 2253. None None None None None 6–2.5%2+4–a 115 115 115 115 150 150 115 135 165 225 200 245 13B 13B 13B 15B 17D 17D kVA 37.5 50 75 100 167 37S3H 50S3H 75S3H 100S3H 167S3H 3003. 3652. 4953. 6403. 9406. 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 150 150 150 150 150 325 350 450 640 975 18D 18D 21D 22D 24D 7.5 10 15 25 200 250 200S3H 250S3H 14814. 19448. 6–2.5%2+4–a 6–2.5%2+4–a 150 150 1220 1535 25D 25D Single Phase – 480 V Primary 120/240 V Secondary 60 Hz UL/cUL Listed through 25 kVA 3 5 7.5 10 15 15 25 3S40F 5S40F 7S40F 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 115 60 115 135 10A 13B 13B 1291. 2069. 1731. 2646. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 150 115 165 225 200 300 13B 15B 17D 15B Single Phase – 600 V Primary 120/240 V Secondary 60 Hz UL Listed through 167 kVA cUL Listed through 10 kVA .050 .100 .150 .250 .500 50SV51A 100SV51A 150SV51A 250SV51B 500SV51B .750 1 1.5 2 750SV51F 1S51F 1.5S51F 2S51F 3 5 7.5 $ Catalog Numberq 1t 2 3 5 1S67F 2S67F 3S67F 5S67F 7S67F 10S67F 15S67H 25S67H Price Full Capacity Taps Deg. C. Weight k Enclosure Temp. Rise (Pounds) ck $ 562. 817. 1090. 1216. None None None None 115 115 115 115 21.2 39.1 55.2 135 7A 9A 10A 13B 1578. 1907. 2995. 4138. None None None None 115 115 150 150 165 165 225 260 13B 13B 17D 17D LUGS: Furnished by customer t 0.750 kVA EN rating per EN 60-742 1-10 kVA CE marked per EN 60-742 Single Phase – Buck and Boost Transformers $ 545. 741. 1042. 10S40F 15S40F 15S40Hj 25S40F V Primary, 110/220 V Secondary 50/60 Hz UL Listed through 25 kVA CE marked/cUL Listed through 10 kVA 87. 102. 125. 138. 194. None None None None None 55 55 55 80 80 4.2 4.5 6.2 10.5 13.8 1A 2A 3A 4A 5A 231. 302. 361. 448. None None None None 115 115 115 115 15.5 21.2 30.1 39.1 6A 7A 8A 9A 3S4F 5S4F 7S4F 590. 798. 1118. 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 115 60 115 135 10A 13B 13B 10 15 25 10S4F 15S5H 25S5H 1391. 1870. 2450. 2–5%FCBN 4–2.5%FCBN 4–2.5%FCBN 115 150 150 165 200 245 13B 17D 17D 37.5 50 75 100 37S5H 50S5H 75S5H 100S5H 3252. 3953. 5353. 6955. 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 150 150 150 150 325 350 450 640 18D 18D 21D 22D 167 167S5H 10806. 4–2.5%FCBN 150 975 24D FCBN: full capacity taps below normal LUGS: furnished by customer Buck and Boost transformers are isolating transformers that have 120 X 240 volt primaries and either 12/24 or 16/32 volt secondaries. When used as isolating transformers they carry the full load stated on the nameplate. By special interconnection of the windings, an autotransformer is obtained. When used this way for bucking or boosting small voltage changes, the kVA load they carry is large compared to their physical size. See bulletin 7414PD9301 (D-FAX 2543) for application tables and wiring diagrams for buck and boost transformers. NOTE: When used to supply a 3-phase, 4-wire load, the source must be 3-phase, 4-wire. Single Phase – 120 x 240 V Primary 60 Hz UL/cUL Listed. Copper Windings. Catalog Numbersq kVA 12/24 V Secondary 16/32 V Secondary Price Degree C Temp. Rise .05 .10 .15 .25 .50 .75 1.0 1.5 2.0 3.0 50SV43A 100SV43A 150SV43A 250SV43B 500SV43B 750SV43F 1S43F 1.5S43F 2S43F 3S43F 50SV46A 100SV46A 150SV46A 250SV46B 500SV46B 750SV46F 1S46F 1.5S46F 2S46F 3S46F $ 98. 117. 131. 156. 200. 263. 322. 395. 510. 705. 55 55 55 80 80 115 115 115 115 115 Weight k (Pounds) Enclosure ck 4.2 4.5 6.2 10.5 13.8 15.5 21.2 30.1 39.1 60 1A 2A 3A 4A 5A 6A 7A 8A 9A f 12 TRANSFORMERS f Dimensions: 14.5" high x 8.6" wide x 6.5" deep. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. q Catalog Numbers shown in bold type are available from Distribution Center. a When 240 volt connection is used, there will be 3–5% taps, 1 above and 2 below 240 volts. c For enclosure styles, see dimensions table, page 12-8. FCBN: full capacity taps below normal LUGS: furnished by customer j 15S40H is UL Listed only. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. For an index of all product information available via D-FAX™ for low voltage transformers, request D-FAX TM number 09. For additional information, reference Selection Guide No. 7400CT9601 or D-FAX TM number 1673 (pages 1-20) and 2284 (pages 21-41). 12-2 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Three Phase Class 7400 kVA kVA Catalog Numberq Price Full Capacity Taps Degree C Weight Enclosure Temp. Rise (Pounds)k ck Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz UL/cUL Listed, Copper Wound. 3 6 9 15 15 30 3T2F 6T2F 9T2F 15T2F 15T68F 30T2F $ 960. 2–5%FCBN 1100. 2–5%FCBN 1470. 2–5%FCBN 2211. 2–5%FCBN 2211. 4–2.5%2+2– 4065. 2–5%FCBN 115 115 115 120 145 235 12C 12C 14C 115 115 115 300 300 660 14C 14C 16C UL Listed Price Full Capacity Taps Degree C Weight Enclosure Temp. Rise (Pounds)k ck Three Phase – 480 V Delta Primary 380Y/220 V Secondary 60 Hz UL Listed 15 30 45 15T96H 30T96H 45T96H 2602. 4–2.5%2+2– 3202. 4–2.5%2+2– 4002. 4–2.5%2+2– 150 150 150 200 250 340 17D 17D 18D 75 112.5 150 75T96H 112T96H 150T96H 5953. 4–2.5%2+2– 7953. 4–2.5%2+2– 9775. 4–2.5%2+2– 150 150 150 500 750 800 19D 21D 22D 225 300 500 225T96H 300T96H 500T96H 13438. 4–2.5%2+2– 17961. 4–2.5%2+2– 27316. 4–2.5%2+2– 150 150 150 1025 1450 2100 24D 25D 30D Three Phase – 600 V Delta Primary 208Y/120 V Secondary 60 Hz UL/cUL Listed, Copper Wound. 6 9 15 Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz Catalog Numberq 6T7F 9T7F 15T7F $ 1169. 2–5%FCBN 1551. 2–5%FCBN 2321. 2–5%FCBN 115 115 115 145 235 300 15 15T3H 2001. 6–2.5%2+4– 150 200 17D Three Phase – 600 V Delta Primary 208Y/120 V Secondary 60 Hz 30 45 75 30T3H 45T3H 75T3H 2952. 6–2.5%2+4– 3553. 6–2.5%2+4– 5353. 6–2.5%2+4– 150 150 150 250 340 500 17D 18D 19D UL Listed 112.5 150 225 300 112T3H 150T3H 225T3H 300T3H 7124. 9306. 12406. 15910. 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 150 150 150 150 750 800 1025 1450 21D 22D 24D 25D 500T68H 750T90H 1000T77H 25215. 4–2.5%2+2– 40973. 4–3.5%2+2– 49428. 2–5%1+1– 150 150 150 2100 3950 6300 30D 31D 33F 500 750 1000 Three Phase – 208 V Delta Primary 480Y/277 V Secondary 60 Hz UL Listed 15 30 45 15T64H 30T64H 45T64H 2602. 2–5%FCBN 3202. 2–5%FCBN 4002. 2–5%FCBN 150 150 150 200 250 340 17D 17D 18D 75 112.5 150 75T64H 112T64H 150T64H 5953. 2–5%FCBN 7953. 2–5%FCBN 9775. 2–5%FCBN 150 150 150 500 750 800 19D 21D 22D 225 300 500 225T64H 300T64H 500T64H 13438. 2–5%FCBN 17961. 2–5%FCBN 27316. 2–5%FCBN 150 150 150 1025 1450 2100 24D 25D 30D Three Phase – 480 V Delta Primary 240 V Delta Secondary 60 Hz UL/cUL Listed, Copper Wound. 6 9 15 6T5F 9T75F 15T75F $ 1100. 2–5%FCBN 1470. 4–2.5%FCBN 2211. 4–2.5%FCBN 115 115 115 145 235 300 12C 14C 14C Three Phase – 480 V Delta Primary 240 V Delta Secondary 60 Hz UL Listed 15 30 45 75 15T6H 30T6H 45T6H 75T6H 2001. 2952. 3553. 5353. 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 150 150 150 150 200 250 340 500 17D 17D 18D 19D 112.5 150 225 300 112T6H 150T6H 225T6H 300T6H 7124. 9306. 12406. 15910. 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 150 150 150 150 750 800 1025 1450 21D 22D 24D 25D 500T63H 750T91H 1000T78H 25014. 4–2.5%2+2– 40774. 4–3.5%2+2– 49027. 2–5%1+1– 150 150 150 2100 3950 6000 30D 31D 33F 500 750 1000 Three Phase – 480 V Delta Primary 240 V Delta Secondary with 120 V Center Tapa – See Note #1, 60 Hz UL Listed 30 45 75 30T6HCT 45T6HCT 75T6HCT 112.5 150 225 300 112T6HCT 150T6HCT 225T6HCT 300T6HCT 7754. 9727. 12868. 17909. 500T63HCT 750T91HCT 1000T78HCT 500 750 1000 $ 3103. 6–2.5%2+4– 3703. 6–2.5%2+4– 5504. 6–2.5%2+4– 75 112.5 150 225 300 500 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 150 150 150 150 200 250 340 500 17D 17D 18D 19D 112T8H 150T8H 225T8H 300T8H 7953. 9775. 13438. 17961. 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 150 150 150 150 750 800 1025 1450 21D 22D 24D 25D 500T8H 750T8H 1000T88H 27316. 4–2.5%FCBN 41584. 4–2.5%FCBN 50030. 4–3.5%FCBN 150 150 150 2100 3950 6600 30D 31D 33F Three Phase – 240 V Delta Primary 208Y/120 V Secondary 60 Hz UL Listed 15 30 45 15T12H 30T12H 45T12H 2602. 4–2.5%2+2– 3202. 4–2.5%2+2– 4002. 4–2.5%2+2– 150 150 150 200 250 340 17D 17D 18D 75 112.5 150 75T12H 112T12H 150T12H 5953. 4–2.5%2+2– 7953. 4–2.5%2+2– 9775. 4–2.5%2+2– 150 150 150 500 750 800 19D 21D 22D 225 300 500 225T11H 300T11H 500T11H 150 150 150 1025 1450 2100 24D 25D 30D 13438. 2–5%FCBN 17961. 2–5%FCBN 27316. 2–5%FCBN Three Phase – Copper Wound Transformers All Square D transformers are available with optional copper windings. Contact your nearest Square D/Schneider Electric sales office for voltage or kVA not listed below. kVA Catalog Numberq Price Full Capacity Taps Deg. C. Weight Enclosure Temp. Rise (Pounds)k ck Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz UL/cUL Listed. Copper Windings. 3 6 9 3T2F 6T2F 9T2F $ 960. 2–5%FCBN 1100. 2–5%FCBN 1470. 2–5%FCBN 115 115 115 120 145 235 12C 12C 14C Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz UL Listed. Copper Windings. 15 30 45 75 15T3HCU 30T3HCU 45T3HCU 75T3HCU $ 3252. 4002. 5001. 7443. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 240 300 385 600 17D 17D 18D 19D 112.5 150 225 300 112T3HCU 150T3HCU 225T3HCU 300T3HCU 9942. 12220. 16798. 22452. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 780 1100 1300 1800 21D 22D 24D 25D 500 750 500T68HCU 750T90HCU 34144. 4–2.5%2 + 2– 55324. 4–3.5%2 +2– 150 150 2550 4800 30D 31D 17D 18D 19D 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 6–2.5%2+4– 150 150 150 150 750 800 1025 1450 21D 22D 24D 25D 25582. 4–2.5%2+2– 40733. 4–3.5%2+2– 49527. 2–3.5%1+1– 150 150 150 2100 3950 6300 30D 31D 33F Three Phase – 480 V Delta Primary 240 V Delta Secondary 60 Hz Three Phase – 480 V Delta Primary 240 V Delta Secondary 60 Hz $ 2602. 4–2.5%2+2– 3103. 4–2.5%2+2– 3721. 4–2.5%2+2– 150 150 150 200 250 340 17D 17D 18D 75T76H 112T76H 150T76H 5603. 4–2.5%2+2– 7504. 4–2.5%2+2– 9705. 4–2.5%2+2– 150 150 150 500 750 800 19D 21D 22D 225T76H 300T76H 500T76H 13107. 4–2.5%2+2– 15972. 4–2.5%2+2– 27014. 4–2.5%2+2– 150 150 150 1025 1450 2100 24D 25D 30D a CAUTION: Single Phase load limited to maximum 5% of rated kVA. Contact your nearest Square D/Schneider Electric sales office for other loading. Note #1: Connect “B” Ø to X3 to meet NEC 384-3. c For enclosure styles, see Dimensions Table, page 12-8. FCBN = Full capacity below normal Lugs: Furnished by customer. Taps on transformers 225 kVA and larger may vary in 3% to 5% steps to obtain best design. 3/00 112.5 150 225 300 500 750 1000 2602. 3103. 3703. 5504. 250 340 500 UL Listed 15T76H 30T76H 45T76H 15T8H 30T8H 45T8H 75T8H 150 150 150 Three Phase – 480 V Delta Primary 480Y/277 V Secondary 60 Hz 15 30 45 15 30 45 75 PE2 12C 14C 14C UL/cUL Listed. Copper Windings. 6 9 15 6T5F 9T75F 15T75F $ 1100. 2–5%FCBN 1470. 4–2.5%FCBN 2211. 4–2.5%FCBN 115 115 115 145 235 300 12C 14C 14C UL Listed. Copper Windings. 15 30 45 75 15T6HCU 30T6HCU 45T6HCU 75T6HCU $ 3252. 4002. 5001. 7443. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 240 300 385 600 17D 17D 18D 19D 112.5 150 225 300 112T6HCU 150T6HCU 225T6HCU 300T6HCU 9942. 12220. 16798. 22452. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 780 1100 1700 1800 21D 22D 24D 25D 500 500T63HCU 34144. 4–2.5%2 + 2– 150 2550 30D TRANSFORMERS General purpose standard transformers are intended for power, heating, and lighting applications. See page 12-4 or contact your nearest Square D/Schneider Electric sales office for voltages not listed below. 12 Three Phase – General Purpose Transformers k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. q Catalog Numbers shown in bold type are available from Distribution Center. Discount Schedule © 2000 Square D All Rights Reserved 12-3 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Special Voltage Transformers, Shielded Isolation Transformers Class 7400 Special Voltage Transformers — Shielded and Non-shielded Square D offers special voltage transformers built to customer specifications. Many options such as lower sound level, copper windings, special frequency, etc. are available but not listed below. Contact your nearest Square D/Schneider Electric sales office for details. Three Phase – Shielded and Non-shielded UL Listed 15 All two-winding transformers are “isolating” or “insulating” because there is no electrical connection between the primary and secondary windings. Additionally, critical equipment might require an electrostatic shield be furnished between primary and secondary to attenuate some of the source line interference and common-mode noise. Protection from transverse-mode transients is obtained by adding surge suppressors and filters to the shielded isolation transformer. These products are listed on page 12-6. Product Data Bulletin 7400PD9202 (D-FAX 2539) describes technical details of shielded and filtered transformers. 30 45 75 112 150 225 300 Price Degree C Temp. Rise Weight (Pounds)k Enclosure ck $ 2602. 2862. 3203. 3523. 4003 4403. 5954. 6549. 7956. 8752. 9777. 10754. 13442. 14786. 17964. 19760. 150 200 17D 150 250 17D 150 340 18D 150 500 19D 150 750 21D 150 800 22D 150 1025 24D 150 1450 25D Electrostatic Shield is indicated by the letters IS at the end of the catalog number. To Complete Catalog Number: Single Phase–Shielded and Non-shielded 1. Select the voltage required from chart 2. UL Listed through 167 kVA cUL Listed through 10 kVA kVA Catalog Number Price 1 1 1.5 1.5 2 2 1S( )F 1S( )FIS 1.5S( )F 1.5S( )FIS 2S( )F 2S( )FIS $ 518. 569. 741. 831. 831. 901. 7 6, 7 None 6, 7 None 6, 7 115 115 115 115 115 115 3 3 5 5 7.5 7.5 3S( 3S( 5S( 5S( 7S( 7S( 901. 951. 1151. 1251. 1531. 1640. None 6, 7 None 6, 7 None 6, 7 115 115 115 115 115 115 60 60 110 110 135 135 10A 10A 13B 13B 13B 13B )F )FIS )F )FIS )F )FIS Stocked Degree C Weight Enclosure Voltage Codes Temp. Rise (Pounds)k ck 21.2 21.2 30.1 30.1 39.1 39.1 7A 7A 8A 8A 9A 9A 10 10 15 15 25 25 10S( 10S( 15S( 15S( 25S( 25S( )F )FIS )H )HIS )H )HIS 1903. 2043. 2591. 2851. 3402. 3742. None 3, 6, 7 None 3, 6, 7 None 3, 6, 7 115 115 150 150 150 150 150 150 205 205 240 240 13B 13B 17D 17D 17D 17D 37.5 37.5 50 50 37S( 37S( 50S( 50S( )H )HIS )H )HIS 3755. 4130. 4568. 5021. None 3 None 3 150 150 150 150 325 325 350 350 18D 18D 18D 18D To Complete Catalog Number: 2. Insert the voltage code number in place of the ( ) in the catalog number. Chart 2 Voltage Code Primary Secondary Full Capacity Taps 127 153 74 10 99 600 Delta 600 Delta 600 Delta 600 Delta 480 Delta 600Y/347 480 Delta 480Y/277 240 Delta 480 Delta 4-2.5% 2+24-2.5% 2+24-2.5% FCBN 4-2.5% FCBN 4-2.5% 2+2- 1834 1841 1768 2463 3tj 480 Delta 480 Delta 480 Delta 480 Delta 480 Delta 600 Delta 600Y/347 416Y/240 400Y/231 208Y/120 4-2.5% 2+24-2.5% 2+24-2.5% 2+24-2.5% 2+26-2.5% 2+4- 911 918 884 890 441 240 Delta 240 Delta 240 Delta 240 Delta 208 Delta 600 Delta 600Y/347 480 Delta 480Y/277 600 Delta 2-5% 1+12-5% 1+12-5% 1+12-5% 1+12-5% 1+1- 447 414 66 85j 208 Delta 208 Delta 208 Delta 208 Delta 600Y/347 480 Delta 240 Delta 208Y/120 2-5% 1+12-5% 1+12-5% FCBN 2-5% FCBN t Use pricing from page 12-3 for non-shielded units. j Use pricing below for shielded units. 1. Select the voltage required from chart 1. Three Phase 480 V Delta Primary 2. Insert the voltage code number in place of the ( ) in the catalog number. Chart 1 TRANSFORMERS Catalog Number 15T( )H 15T( )HIS 30T( )H 30T( )HIS 45T( )H 45T( )HIS 75T( )H 75T( )HIS 112T( )H 112T( )HIS 150T( )H 150T( )HIS 225T( )H 225T( )HIS 300T( )H 300T( )HIS kVA Voltage Code Primary Secondary Full Capacity Taps 6 7 60 f 9 1292 120x240 208 208 208 208 120/240 120/240 120/240 208 277 None None 2-5% FCBN None None 8 61 f 3f 72 78 277 277 240x480 480 480 120/240 120/240 120/240 208 277 None 2-5% FCBN 6-2.5% 2+4None None k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. c For enclosure styles, see Dimensions Table, page 12-8. FCBN = Full capacity below normal Lugs: Furnished by customer. Taps on transformers 225 kVA and larger may vary in 3% to 5% steps to obtain best design. f Taps are available on transformers 10 kVA and larger. 208Y/120 V Secondary 60 Hz with Electrostatic Shield, UL Listed kVA 9 15 30 45 75 112.5 150 225 300 500 Catalog Number q 9T2FIS 15T3HIS 30T3HIS 45T3HIS 75T3HIS 112T3HIS 150T3HIS 225T3HIS 300T3HIS 500T68HIS Price Stocked Degree C Weight Enclosure Voltage Codes Temp. Rise (Pounds)k ck $ 2201. 2741. 3452. 4152. 6254. 2–5%FCBN 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 115 150 150 150 150 235 200 250 340 500 14C 17D 17D 18D 19D 8143. 10389. 13913. 18261. 27930. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 4–2.5%2 + 2– 150 150 150 150 150 815 800 1025 1450 2100 21D 22D 24D 25D 30D 208 V Delta Primary 208Y/120 V Secondary 60 Hz with Electrostatic Shield, UL Listed 9 15 30 45 75 9T85FIS 15T85HIS 30T85HIS 45T85HIS 75T85HIS $ 2201. 2741. 3452. 4152. 6254. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 150 150 150 150 235 200 250 340 500 14C 17D 17D 18D 19D 112.5 150 225 300 500 112T85HIS 150T85HIS 225T85HIS 300T85HIS 500T85HIS 8143. 10389. 13913. 18261. 27930. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 150 150 150 150 150 815 800 1025 1450 2100 21D 22D 24D 25D 30D 12 q Catalog Numbers shown in bold type are available from Distribution Center. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. c For enclosure styles, see Dimensions Table, page 12-8. FCBN = Full capacity below normal Lugs: Furnished by customer. Taps on transformers 225 kVA and larger may vary in 3% to 5% steps to obtain best design. 12-4 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below EE Energy Efficient Transformers Class 7400 WATCHDOG®, Type The Environmental Protection Agency (EPA) has determined 61 billion kWH of electricity is wasted each year in transformer losses. Square D offers a complete line of transformers that can significantly reduce energy losses. Surveys have shown the 24-hour average loading of low voltage dry type transformers in the United States is appoximately 35% of nameplate rating. The new Type EE Energy Efficient Transformers are optimized for maximum efficiency at these most common loading levels. Square D WATCHDOG 115°C or 80°C rise transformers offer significant energy savings in less common applications where the average daily loading exceeds 50% of nameplate rating. Type EE Energy Efficient Transformers WATCHDOG Low Temperature Rise Transformers k Comply with NEMA standard TP-1 for optimum energy efficiency at 35% load. k Designed for low energy losses at loads greater than 50% of nameplate rating. k Labeled for EPA Energy Star program. k More efficient than standard 150°C rise transformers at all load levels. k Extra long life expectancy using 220°C insulation system designed for full load operation at a maximum temperature rise of 115°C or 80°C instead of 150°C. k Identical dimensions to standard, 150°C rise General Purpose transformers. k Continuous emergency overload capability of 15% on 115°C rise and 30% on 80°C rise. k Cost optimized to allow energy savings payback to owner in average 3–5 year period based on energy rate of $0.065 per kWH. kVA Catalog Numberq Price Full Capacity Taps Weight Enclosure Degree C Temp. Rise (Pounds) ck k Single Phase – 240x480 V Primary 120/240 V Secondary 60 Hz UL Listed 15 25 15S1HEE 25S3HEE 37.5 50 75 100 167 37S3HEE 50S3HEE 75S3HEE 100S3HEE 167S3HEE $ 2250. None 2929. 6–2.5%2 + 4–a 3904. 4748. 6439. 8324. 12288. 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 150 150 190 270 17D 17D 150 150 150 150 150 340 395 575 818 1246 18D 18D 21D 22D 24D Three Phase–480 V Delta Primary 208Y/120 V Secondary 60 Hz UL Listed kVA Catalog Numberq Price Full Capacity Taps Weight (Pounds)k Enclosurec k 115°C Rise Single Phase – 240x480 V Primary 120/240 V Secondary 60 Hz UL Listed 15 25 37.5 50 75 100 15S3HF 25S3HF 37S3HF 50S3HF 75S3HF 100S3HF $ 2209. 2870. 3601. 4804. 6503. 7304. 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 230 325 350 450 650 1050 17D 18D 18D 21D 22D 24D 80°C Rise Single Phase – 240x480 V Primary 120/240 V Secondary 60 Hz UL Listed 15 25 37.5 50 75 100 15S3HB 25S3HB 37S3HB 50S3HB 75S3HB 100S3HB $ 2425. 3150. 3992. 5282. 7155. 8036. 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 6–2.5%2 + 4–a 230 325 350 450 675 1100 17D 18D 18D 21D 22D 24D 15 15T3HEE $ 2600. 6–2.5%2 + 4– 150 218 17D 115°C Rise Three Phase–480 V Delta Primary 208Y/120 V Secondary 60 Hz 30 45 75 30T3HEE 45T3HEE 75T3HEE 3185. 6–2.5%2 + 4– 4795. 6–2.5%2 + 4– 7225. 6–2.5%2 + 4– 150 150 150 266 382 546 17D 18D 19D UL Listed 112.5 150 225 300 112T3HEE 150T3HEE 225T3HEE 300T3HEE 9625. 12565. 16750. 21480. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 657 816 1162 1646 21D 22D 24D 25D 500 750 500T68HEE 750T90HEE 30040. 4–3.5%2 + 2– 55315. 4–3.5%2 + 2– 150 150 2170 3000 30D 31D k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. 15 30 45 75 112.5 150 225 300 500 15T3HFj 30T3HFj 45T3HFj 75T3HFj 112T3HFj 150T3HFj 225T3HF 300T3HFj 500T90HF $ 2401. 3553. 5353. 7103. 8905. 11877. 16410. 19952. 29218. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 4–3.5%2 + 2– 250 340 500 620 800 1025 1450 2495 3450 17D 18D 19D 21D 22D 24D 25D 30D 31D 80°C Rise Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz UL Listed For additional information reference Bulletin No. 7400CT9801 or D-Fax™ number 2893. 15 30 45 75 112.5 150 225 300 500 15T3HBj 30T3HBj 45T3HBj 75T3HBj 112T3HB 150T3HB 225T3HB 300T3HBj 500T90HB $ 2578. 3801. 5703. 7603. 9606. 12907. 18052. 21953. 32519. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 4–3.5%2 + 2– 250 340 500 750 850 1075 1450 2100 3900 17D 18D 19D 21D 22D 24D 25D 30D 31D 12 TRANSFORMERS c For enclosure styles, see Dimensions Table on page 12-8. a When 240 volt connection is used, there will be 3-5% taps, 1 above and 2 below 240 volts. FCBN = Full Capacity Below Normal Lugs: furnished by customer. q Catalog numbers shown in bold type are available from Distribution Center. j Available from Distribution Center with copper windings. Add suffix CU to complete catalog number. Example: 15T3HFCU. 3/00 PE2 Discount Schedule © 2000 Square D All Rights Reserved 12-5 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below K-Rated, Shielded Filtered and Drive Isolation Transformers Class 7400 Transformers Designed for High Harmonic Loads – NL and NLP Series Drive Isolation Transformers – Three Phase • Class 220 insulation Special design considerations must be made for the requirements of both adjustable frequency and dc motor drive power isolation. Allowance for high surge, harmonic and offset currents are taken into account in the design of Square D Company drive isolation transformers. Drive isolation transformers are not shielded isolation transformers, but act to lessen transient generation into the supply power and act as a buffer for SCR current surges. UL Listed. • NLP Series has maximum sound level 3dB below NEMA Standard Three Phase • Three phase dry type transformers, 480 Delta – 208Y/120 • Aluminum or Copper windings • Electrostatic shield • 115 degree C temperature rise standard j • Double size neutral terminal for additional customer neutral cables kVA Catalog Numberq • Additional coil capacity to compensate for higher non-linear load loss 7.5 11 15 20 27 7T( )HDIT 11T( )HDIT 15T( )HDIT 20T( )HDIT 27T( )HDIT 34 40 51 63 75 34T( 40T( 51T( 63T( 75T( • Heavy gauge ventilated indoor enclosures (weathershields available) • UL Listed NL Series for Typical Non-Linear Load Service – UL K-4 Rated – Aluminum Windings kVA Catalog Numberq Price Taps Weight (Pounds)k Enclosure ck 15 30 45 15T3HFISNL 30T3HFISNL 45T3HFISNL $ 2545. 3904. 4513. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 240 300 500 17D 18D 19D 75 112.5 150 75T3HFISNL 112T3HFISNL 150T3HFISNL 6164. 10259. 13734. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 725 800 985 21D 22D 24D 225 300 500 225T3HFISNL 300T68HFISNL 500T90HFISNL 20892. 28941. 39984. 6-2.5% 2+44-2.5% 2+24-3.5% 2+2- 1450 1725 3600 25D 30D 29D 15 30 45 15T3HFISNLP 30T3HFISNLP 45T3HFISNLP $ 3340. 4590. 5394. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 245 350 600 17D 18D 19D 75 112.5 150 75T3HFISNLP 112T3HFISNLP 150T3HFISNLP 7637. 15755. 19137. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 725 850 1380 22D 22D 25D 225 300 500 225T3HFISNLP 300T68HFISNLP 500T90HFISNLP 27897. 39217. 59820. 6-2.5% 2+44-2.5% 2+24-3.5% 2+2- 2010 2100 4000 25D 30D 32F 15 30 45 15T3HFISCUNL 30T3HFISCUNL 45T3HFISCUNL $ 4292. 6588. 7615. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 330 380 475 18D 18D 18D 75 112.5 150 75T3HFISCUNL 112T3HFISCUNL 150T3HFISCUNL 10404. 17315. 23181. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 865 925 1275 21D 22D 24D 225 300 225T3HFISCUNL 300T68HFISCUNL 35257. 39071. 6-2.5% 2+44-2.5% 2+2- 1700 2750 25D 25D NLP Series for More Severe Non-Linear Load Service – UL K-13 Rated – Copper Windings 15 30 45 15T3HFISCUNLP 30T3HFISCUNLP 45T3HFISCUNLP $ 5635. 7745. 9103. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 310 370 600 18D 18D 19D 75 112.5 150 75T3HFISCUNLP 112T3HFISCUNLP 150T3HFISCUNLP 12919. 22649. 32294. 6-2.5% 2+46-2.5% 2+46-2.5% 2+4- 875 1100 1500 22D 22D 25D 225 300 225T3HFISCUNLP 300T68HFISCUNLP 37661. 52953. 6-2.5% 2+44-2.5% 2+2- 1700 2600 25D 30D TRANSFORMERS q Catalog Numbers shown in bold type are available from Distribution Center. c For enclosure styles, see dimensions table, page 12-8. FCBN = Full capacity below normal LUGS: Furnished by customer k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. j Available with optional 80° C temperature rise. To complete catalog number, replace “F” with “B”. Example: 15T3HBISNL. For additional information on Type NL/NLP Transformers reference 7455BR9301. For additional information on Drive Isolation Transformers reference 7460PD9501. For additional information on Thermal Switch Kit for DITs reference 7400PD9701. © 2000 Square D All Rights Reserved C. Weight StockVoltage Degree Temp. (Pounds) Codes Rise k Price Enclosure ck $ 2125. 2523. 2602. 3119. 3200. 144, 145 144, 145 144, 145 144, 145 144, 145 150 150 150 150 150 180 180 190 210 250 17D 17D 17D 17D 17D 3520. 4002. 4679. 5091. 5951. 144, 145 144, 145 144, 145 144, 145 144, 145 150 150 150 150 150 295 350 445 465 550 18D 18D 20D 20D 20D 93T( )HDIT 118T( )HDIT 145T( )HDIT 175T( )HDIT 220T( )HDIT 7629. 8497. 9528. 10996. 13440. 144, 145 145 145 145 145 150 150 150 150 150 845 920 1025 1120 1200 22D 22D 22D 25D 25D 275 330 440 550 275T( 330T( 440T( 550T( 17960. 18899. 23167. 28783. 145 145 None None 150 150 150 150 1500 1390 2700 3800 25D 25D 30D 30D )HDIT )HDIT )HDIT )HDIT Voltage Codes Code Primary Secondary 142 143 144 230 Delta 230 Delta 460 Delta 230Y/132 460Y/265 230Y/132 145 146 147 460 Delta 575 Delta 575 Delta 460Y/265 230Y/132 460Y/265 Full Capacity Taps 2-5%1 + 1– To Complete Catalog Number: 1. Select the voltage required from chart. 2. Insert the voltage code number in place of the ( ) in the catalog number. NL Series for Typical Non-Linear Load Service – UL K-4 Rated – Copper Windings 12-6 )HDIT )HDIT )HDIT )HDIT )HDIT Class B (IEEE Standard 597-1983) 93 118 145 175 220 NLP Series for More Severe Non-Linear Load Service – UL K-13 Rated – Aluminum Windings 12 60 Hz PE2 Shielded Transformers with Filters – Three Phase Additional attenuation of transverse (across-the-line) surges and transients is available with the addition of primary surge suppression and secondary filters. For details, see Product Data Bulletin 7400PD9202. Surge suppression and filtering are indicated by the letters FIL at the end of the catalog number. 480 V Delta Primary 208Y/120 V Secondary 60 Hz with Electrostatic Shield, Surge Suppressors and Filter – UL Listed kVA Catalog Numberq Price 15 30 45 75 112.5 15T3HISFIL 30T3HISFIL 45T3HISFIL 75T3HISFIL 112T3HISFIL $ 5907. 6617. 8024. 10127. 12581. 150 225 150T3HISFIL 225T3HISFIL C. Weight Full Capacity Degree Temp. (Pounds) Taps Rise k Enclosure ck 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 150 265 295 390 610 840 19D 19D 19D 21D 22D 14827. 6–2.5%2 + 4– 18703. 6–2.5%2 + 4– 150 150 1100 1400 25D 26D 208 V Delta Primary 208Y/120 V Secondary 60 Hz with Electrostatic Shield, Surge Suppressors and Filter – UL Listed 15 30 45 75 112.5 15T85HISFIL 30T85HISFIL 45T85HISFIL 75T85HISFIL 112T85HISFIL $ 5907. 6617. 8024. 10127. 12581. 2–5% FCBN 2–5% FCBN 2–5% FCBN 2–5% FCBN 2–5% FCBN 150 150 150 150 150 265 295 390 610 840 19D 19D 19D 21D 22D 150 225 150T85HISFIL 225T85HISFIL 14827. 18703. 2–5% FCBN 2–5% FCBN 150 150 1100 1400 25D 26D c For enclosure styles, see Dimensions Table on page 12-8. FCBN = Full Capacity Below Normal Lugs: furnished by customer. q Catalog numbers shown in bold type are available from Distribution Center. Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Stainless Steel, Non-Ventilated Transformers Class 7400 Stainless Steel Enclosed Transformers– Single and Three Phase Non-Ventilated Transformers – Single and Three Phase Stainless steel enclosures provide better corrosion resistance than standard painted enclosures. Square D has a complete line of stainless steel transformers to meet demands for extra protection in corrosive environments. Non-ventilated enclosures are used in environments where large quantities of dust, airborne contaminants, metal particles, or moisture make ventilated transformers impractical. These transformers are also used when water spray from any direction is possible. The transformers listed below are built with an epoxy-resin encapsulated core and coil assembly inside of a non-ventilated #316 stainless steel enclosure. Terminals are flexible copper lead wire. When connections are made using an appropriate method, the final transformer installation is virtually impervious to contamination from materials such as acids, food products, organic solvents, salt water, or similar. Transformers are UL listed for NEMA Type 3R indoor or outdoor use. The 150 rise transformers listed below are built using 220 class insulated core and coil assemblies similar to ventilated units. However, the core and conductors are oversized to maintain proper temperature rise with the limited cooling capacity of a non-ventilated enclosure. Therefore non-ventilated transformers are larger and heavier than the same kVA and voltage ventilated equivalent. Additional voltages not listed below and UL Listed NEMA Type 4X enclosures are available. Contact your nearest Square D/Schneider Electric sales office for details. Ventilated and non-ventilated transformers built using #304 stainless steel enclosures are also available. These are well suited for moderately corrosive locations where enclosure protection and appearance are important. Contact your nearest Square D/Schneider Electric sales office for details. Single Phase – 240x480 V Primary 120/240 V Secondary 60 Hz UL Listed Degree C Weight Temperature (Pounds) Enclosure ck Rise k Catalog Number Price Full Capacity Taps 1 1.5 2 1S1FSS 1.5S1FSS 2S1FSS $ 607. 847. 911. None None None 115 115 115 21 30 39 7A 8A 9A 3 5 7.5 3S1FSS 5S1FSS 7S1FSS 1278. 1848. 1983. None None None 115 115 115 60 110 135 10A 13B 13B 10S1FSS 15S1FSS 25S1FSS 2269. 3350. 4574. None None None 115 115 115 150 225 300 13B 15B 15B KVA 10 15 25 Single Phase – 480 V Primary 3 5 7.5 10 15 25 Non-ventilated enclosures meet protection code IP55 (dust and jetting water protection) per standard IEC-529. While not listed to a specific NEMA standard, they are suitable for indoor or outdoor use. kVA Catalog Numberq Price Full Capacity Taps Weight Enclosure Degree C Temp. Rise (Pounds) ck k Single Phase – 240X480 V Primary 120/240 V Secondary 60 Hz 15 25 37.5 50 75 100 15S3HNV 25S3HNV 37S3HNV 50S3HNV 75S3HNV 100S3HNV $ 2401. 3601. 5356. 6850. 8381. 10612. 6–2.5%2 + 4–★ 6–2.5%2 + 4–★ 6–2.5%2 + 4–★ 6–2.5%2 + 4–★ 6–2.5%2 + 4–★ 6–2.5%2 + 4–★ 150 150 150 150 150 150 230 310 350 450 880 975 17E 18E 18E 21E 24E 25E 230 310 350 450 880 975 17E 18E 18E 21E 24E 25E Single Phase – 600 V Primary 120/240 V Secondary 60 Hz 15 25 37.5 50 75 100 15S5HNV 25S5HNV 37S5HNV 50S5HNV 75S5HNV 100S5HNV $ 2582. 3893. 5884. 6830. 9297. 11452. 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 150 150 150 150 150 150 Three Phase – 480 V Delta Primary 208Y/120 V Secondary 60 Hz 120/240 V Secondary 60 Hz UL Listed 3S40FSS 5S40FSS 7S40FSS $1278. 1848. 1983. 2-5% FCBN 2-5% FCBN 2-5% FCBN 115 115 115 60 110 135 10A 13B 13B 10S40FSS 15S40FSS 25S40FSS 2269. 3350. 4574. 2-5% FCBN 2-5% FCBN 2-5% FCBN 115 115 115 150 225 300 13B 15B 15B Three Phase – 480 V Delta Primary The 115 rise epoxy-resin encapsulated transformers listed below are furnished non-ventilated at standard price. 208Y/120 V Secondary 60 Hz UL Listed 3 6 9 3T2FSS 6T2FSS 9T2FSS $1960. 2345. 2891. 2-5% FCBN 2-5% FCBN 2-5% FCBN 115 115 115 120 145 234 12C 12C 14C 15 30 15T2FSS 30T2FSS 3679. 6201. 2-5% FCBN 2-5% FCBN 115 115 300 660 14C 16C k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. 15 30 30 45 15T68F 30T2F 30T3HNV 45T3HNV $ 2211. 4065. 3852. 5903. 4–2.5%2 + 2– 2–5%FCBN 6–2.5%2 + 4– 6–2.5%2 + 4– 115 115 150 150 300 660 340 510 14C 16C 19E 19E 75 112.5 150 225 300 75T3HNV 112T3HNV 150T3HNV 225T3HNV 300T3HNV 9104. 12309. 15880. 23923. 26263. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 150 150 150 150 150 1025 1250 2000 2100 3300 22E 24E 25E 23E 28E Three Phase – 480 V Delta Primary 240 V Delta Secondary 60 Hz 15 30 45 15T75F 30T6HNV 45T6HNV 75 112.5 150 225 300 75T6HNV 112T6HNV 150T6HNV 225T6HNV 300T6HNV $ 2211. 4–2.5%FCBN 3852. 6–2.5%2 + 4– 5903. 6–2.5%2 + 4– 9104. 12309. 15880. 23923. 26263. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 115 150 150 300 340 510 14C 19E 19E 150 150 150 150 150 1025 1250 2000 2100 3300 22E 24E 25E 23E 28E 15 30 45 15T7F 30T8HNV 45T8HNV 75 112.5 150 225 300 75T8HNV 112T8HNV 150T8HNV 225T8HNV 300T8HNV $ 2321. 2–5%FCBN 4203. 4–2.5%FCBN 6403. 4–2.5%FCBN 9805. 13307. 15910. 24621. 27014. 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 115 150 150 300 340 510 14C 19E 19E 150 150 150 150 150 1025 1250 2000 2100 3300 22E 24E 25E 23E 28E 12 q Catalog Numbers shown in bold type are available from Distribution Center. c For enclosure styles, see dimensions table, page 12-8. a When 240 volt tap is used, there will be 3–5% taps, 1 above and 2 below. FCBN = full capacity below normal Lugs: furnished by customer TRANSFORMERS Three Phase – 600 V Delta Primary 208Y/120 V Secondary 60 Hz 3/00 PE2 Discount Schedule © 2000 Square D All Rights Reserved 12-7 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Enclosures Class 7400 Enclosure Styles Table 1: Enclosure Dimensions and Accessories (Note 1) Enclosure Number/ Style Style A–NEMA Type 3R Rated Style B– NEMA Type 3R Rated Style C –NEMA Type 3R Rated IN mm Depth IN mm Mtg. Weathershield Wall Mounting Bracket Ceiling Mounting Bracket Insulation Class °C A 5 127 4.47 114 3.44 87 Wall Note 2 Note 3 — 105 2 A 5.5 140 4.47 114 3.44 87 Wall Note 2 Note 3 — 105 3 A 5 127 4.85 123 3.75 95 Wall Note 2 Note 3 — 105 4 A 5.5 140 5.23 133 4.06 103 Wall Note 2 Note 3 — 130 5 A 6.19 157 6.19 157 4.69 119 Wall Note 2 Note 3 — 130 6 A 6.69 170 6.19 157 4.69 119 Wall Note 2 Note 3 — 180 7 A 8.13 270 6.94 176 5.31 135 Wall Note 2 Note 3 — 180 8 A 8.25 210 8.68 220 6.56 167 Wall Note 2 Note 3 — 180 9 A 9.56 243 8.68 220 6.56 167 Wall Note 2 Note 3 — 180 10 A 10.5 267 8.62 219 6.5 165 Wall Note 2 Note 3 — 180 11 A 12.56 319 8.62 219 6.5 165 Wall Note 2 Note 3 — 180 12 C 13.5 343 14.75 375 9 229 Wall Note 2 Note 3 — 180 13 B 14.75 375 248 11.75 298 Wall Note 2 Note 3 — 180 14 C 14.75 375 19.1 485 12.25 311 Wall Note 2 Note 3 — 180 15 B 20 508 15 381 13.5 343 Wall Note 2 Note 3 — 180 Note 3 — 16 18 19 20 21 22 23 24 25 26 9.75 C 22 559 25 635 13.5 343 Wall Note 2 D 27 686 20 508 16 406 Floor WS363 180 WMB361–362 CMB363 220 E 27 686 20 508 16 406 Floor Note 5 WMB361–362 CMB363 220 D 30 762 20 508 20 508 Floor WS363 WMB363–364 CMB363 220 E 30 762 20 508 20 508 Floor Note 5 WMB363–364 CMB363 220 D 30 762 30 762 20 508 Floor WS364 WMB363–364 CMB364 220 E 30 762 30 762 20 508 Floor Note 5 WMB363–364 CMB364 220 D 37 940 30 762 20 508 Floor WS364 WMB363–364 CMB364 220 WMB363–364 CMB364 E 37 940 30 762 20 508 Floor Note 5 D 37 940 30 762 24 610 Floor WS364 N/A CMB364 220 220 E 37 940 30 762 24 610 Floor Note 5 N/A CMB364 220 D 43.75 1111 32 813 27 686 Floor WS380 N/A CMB380 220 E 43.75 1111 32 813 27 686 Floor Note 5 N/A CMB380 220 E 48 1219 29.5 749 Floor Note 5 N/A N/A 220 220 1219 48 D 49.5 1257 35 889 28.5 724 Floor WS381 N/A CMB381 E 49.5 1257 35 889 28.5 724 Floor Note 5 N/A CMB381 220 D 49.5 1257 41 1041 32 813 Floor WS382 N/A N/A 220 E 49.5 1257 41 1041 32 813 Floor Note 5 N/A N/A 220 D 57.5 1461 41 1041 32 813 Floor WS382 N/A N/A 220 D 60 1524 56 1422 36 914 Floor WS370A N/A N/A 220 E 60 1524 56 1422 36 914 Floor Note 5 N/A N/A 220 29 D 68 1727 56 1422 36 914 Floor WS370A N/A N/A 220 30 D 71 1803 48 1219 36 914 Floor WS383 N/A N/A 220 31 D 74 1880 56 1422 40.5 1029 Floor WS384 N/A N/A 220 32 F 94 2388 56 1422 54 1372 Floor Note 4 N/A N/A 220 33 F 94 2388 72 1829 54 1372 Floor Note 4 N/A N/A 220 34 F 94 2388 84 2134 54 1372 Floor Note 4 N/A N/A 220 35 F 94 2388 96 2438 54 1372 Floor Note 4 N/A N/A 220 28 Style E–IP55 Rated Width mm 1 17 Style D –NEMA Type 2 Rated Converts to NEMA Type 3R with Weathershield Height IN 12 TRANSFORMERS Note 1: These dimensions are not for construction. Contact your nearest Square D/Shneider Electric sales office for certified prints. Note 2: Transformer is NEMA Type 3R Standard. Weathershield not required for outdoor use. Note 3: Wall mounting brackets are a standard part of transformer enclosure. Accessory not required. Note 4: Special outdoor construction required for NEMA Type 3R applications. Contact your nearest Square D/Schneider Electric sales office for details. Note 5: Indoor/outdoor enclosure standard. Weathershield not required. N/A: Wall mounting/ceiling mounting bracket not available due to weight of these parts. Style F–NEMA Type 1 Rated 12-8 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Enclosure Replacement Parts, Accessories, Lug Kits and Sound Levels Class 7400 Replacement Enclosure Parts List for Low Voltage Stock Transformers Enclosure Number–Style 17–D 18–D 19–D 21–D 22–D 24–D 25–D Base 43101-914-01 43055-018-01 43055-009-01 43055-124-50 43101-895-50 43101-912-50 43101-904-50 Top Cover 43101-915-01 43055-021-01 43055-012-01 43055-125-01 43101-890-01 43101-907-01 43101-899-01 30-D 43101-934-50 43101-926-01 Part Number Frontj 43101-916-01 43055-020-01 43055-011-01 43005-074-02 43101-891-01 43101-908-01 43101-900-01 Upper: 43101-929-01 Lower: 43101-930-01 Rear 43101-916-01 43055-020-01 43055-011-01 43005-074-02 43101-891-01 43101-908-01 43101-900-01 Upper: 43101-929-01 Lower: 43101-930-01 Sides (Ends) 43101-917-01 43055-010-01 43055-010-01 43055-126-01 43101-892-01 43101-909-01 43101-901-01 43101-928-01 j When replacing a front panel, specify tranformer catalog number and “with nameplate and labels” on order. Transformer Lug Kits VERSAtile™ Compression Lugs and Mechanical Set-Screw Types – UL Listed Lugs AL9CU (90°C Rated) Transformer kVA Sizes Kit Catalog Number Terminal Lugs Price Per Kit VERSAtileTM Compression Equipment Lugs 15-371⁄2 1Ø VCEL-SK1 $ 180. 15-45 3Ø 50-75 1Ø VCEL-SK2 292. 75-1121⁄2 3Ø 100-167 1Ø 150-300 3Ø VCEL-SK3 500 3Ø VCEL-SK4 Mechanical Set – Screw Type Lugs 15-371⁄2 1Ø DA-SK1 15-45 3Ø 50-75 1Ø DA-SK2 75-1121⁄2 3Ø 100-167 1Ø DA-SK3 150-300 3Ø 500 3Ø DA-SK4 Qty. Catalog Number 8 5 VCEL-021-14S1 VCEL-030-516H1 13 3 26 1666. Aluminum or Copper Conductor Range (AWG or kcmil) Hardware Included Qty. #8–1/0 #4–300 kcmil VCEL-030-516H1 #4–300 kcmil VCEL-030-516H1 VCEL-075-12H1 #4–300 kcmil 500–750 kcmil Al 500 kcmil Cu 500–750 kcmil Al 500 kcmil Cu VCEL-075-12H1 Type 8 1 8 8 3 1⁄4" 1⁄4" 16 3⁄8" x 2" Cap Screws 21 3⁄8" x 2" Cap Screws x 1" Cap Screws x 1" Cap Screws x 2" Cap Screws 1⁄4" x 1" Cap Screws 1⁄4" x 2" Cap Screws 1⁄4" x 3⁄4" Cap Screws 1812. 34 59. 8 5 DA-2 DA-250 #14–#2 #6–250 kcmil 9 1⁄4" 104. 13 DA-250 #6–250 kcmil 1⁄4" 1⁄4" 481. 3 26 34 DA-250 DA-600 DA-600 #6–250 kcmil #2–600 kcmil #2–600 kcmil 8 8 3 16 21 656. x 1" Cap Screws x 13⁄4" Cap Screws x 1" Cap Screws x 2" Cap Screws 3⁄8" x 2" Cap Screws 1⁄4" 3⁄8" FINGERSAFE® Terminal Block Cover Kit for Encapsulated Transformers Can be used to meet touch-safe requirements of EN60-204. Fits Enclosure Kit Catalog Number Price 7A (1 kVA) 9A (2 kVA) 10A (3 kVA) 13B (5–10 kVA) 7400ENT9 7400ENT11 7400ENT11 7400 ENT13 $ 95. 95. 95. 145. Add Height to Dimensions on page 12-8 1.5 IN/39 mm 1.5 IN/39 mm 1.5 IN/39 mm 2.0 IN/51 mm Weathershields, Wall Mounting Brackets and Ceiling Mounting Brackets Weathershields q c k t Wall Mounting Bracketsc Ceiling Mounting Bracketsk Catalog Numberq Price Catalog Numberq Price Catalog Numberq WS363 WS364 WS370A WS380 No charge t $ 219. 1706. 500. WMB-361-362 WMB-363-364 ... ... No charge t No charge t ... ... CMB363 CMB364 CMB380 CMB381 WS381 WS382 WS383 WS384 500. 850. 851. 1808. ... ... ... ... ... ... ... ... ... ... ... ... Price $220. 220. 549. 549. ... ... ... ... Catalog Numbers shown in bold type are available from Distribution Center. Wall mounting breackets may be prohibited in some California areas requiring 12" spacing from wall. Base Channels are supplied for ceiling mounting–trapeze hangers must be furnished by user. Subject to minimum billing and freight charges when not ordered with transformer. Sound Levels NEMA Standard Sound Level 40 dB 45 dB 50 dB 55 dB 60 dB 62 dB 64 dB TRANSFORMERS kVA 0–9 10–50 51–150 151–300 301–500 501–700 701–1000 12 Square D transformers meet NEMA standards for sound level. Lower sound levels are available at an additional charge. FINGERSAFE is a Registered Trademark of Square D Company or related companies. VERSAtile is a Trademark of Square D Company or related companies. 3/00 PE2 Discount Schedule © 2000 Square D All Rights Reserved 12-9 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MINI POWER-ZONE® Transformers Indoor/Outdoor Packaged Power Supply Class 7400 MINI POWER-ZONE, UL Listed, Suitable for Use as Service Equipment The MINI POWER-ZONE® power supply from Square D Company provides the answer to requirements for a portable, compact power supply for small loads. Because the MINI POWER ZONE is furnished as a complete package, considerable savings in installation time and costs can be realized. Its NEMA 3R enclosure is suitable for both indoor and outdoor use. The transformer is copper wound, 115°C rise, and epoxy-resin encapsulated. The panel section has copper bus and uses QO® style circuit breakers. MINI POWER-ZONE centers are furnished with factory-installed primary main and secondary main circuit breakers only. Circuit breaker ratings are selected to meet National Electrical Code requirements and to coordinate with transformer magnetizing inrush current. Feeder circuit breakers are standard Square D QO plug-on type which should be ordered, as required, from your local Square D distributor’s stock. If ground fault protection is required, QWIK-GARD ® circuit breakers may be used in all sizes. Tandem breakers are not permitted. The MINI POWER-ZONE uses a separate transformer and panel board section. This allows the panel section to be removed and wired first if desired. Also the transformer can be replaced without disturbing the panel section and associated wiring. The new transformer simply slides into the top of the panel section and primary and secondary leads are reconnected to the main circuit breakers. Options Available on Special Order (UL Listed) Contact Factory for Pricing 1. For primary breaker shunt trip, add suffix “SH” with coil voltage. EX: MPZ25S40FSH120. 2. For electrostatic shielding, add suffix “IS”. EX: MPZ10S40FIS. 3. To accommodate QOB bolt-on feeder circuit breakers, add “B” after “MPZ”. EX: MPZB5S40F. 4. To have unit manufactured with painted 316 stainless steel enclosure add “SS” Example: MPZ15T2FSS. Standard Voltages kVA Catalog Numberq Price High Voltage Low Voltage Full Capacity Taps Weight (Pounds) Dimensions (Inches)f H W D Primary Main Circuit Breaker Feeder Breakers Secondary Main Circuit Breaker Maximum Number Maximum 1-Pole or 2-Pole Amps Single Phase 5 7.5 10 MPZ5S40F MPZ7S40F MPZ10S40F $1852. 2163. 2351. 480 480 480 240/120 240/120 240/120 2-5% FCBN 2-5% FCBN 2-5% FCBN 175 200 215 32.7 32.7 32.7 12.0 12.0 12.0 11.9 11.9 11.9 FAL24020 20 A FAL24030 30 A FAL24040 40 A QO-230 QO-240 QO-260 30 A 40 A 60 A 6 or 3 8 or 4 10 or 5 20 30 40 15 25 MPZ15S40F MPZ25S40F 3052. 4552. 480 480 240/120 240/120 2-5% FCBN 2-5% FCBN 390 390 42.9 42.9 17.4 17.4 13.5 13.5 FAL24060 60 A FAL24100 100 A QO-280 QO-2125 80 A 125 A 16 or 8 24 or 12 60 100 Maximum Number 1-Pole or 3-Pole Three Phase 15 22.5 30 MPZ15T2F MPZ22T2F MPZ30T2F $4804. 5953. 7304. 480s 480s 480s 208Y/120 208Y/120 208Y/120 2-5% FCBN 2-5% FCBN 2-5% FCBN 710 725 755 44.6 44.6 44.6 27.4 27.4 27.4 13.6 13.6 13.6 FAL 34040 40 A FAL 34070 70 A FAL 34090 90 A QO-360 QO-380 QO-3100 60 A 80 A 100 A 12 or 4 18 or 6 24 or 8 40 60 80 Basic assemblies include main primary and secondary breakers. Order required QO plug-on feeder breakers. QWIK-GARD breakers, or QOFP filler plates for blank spaces from the Square D Catalog Digest through your local Square D distributor. Special Voltages kVA Catalog Numberq Price Full Capacity Taps Weight (Pounds) Dimensions (Inches)f H W D Primary Main Circuit Breaker 240 V Primary 600 V Primary Secondary Main Circuit Breaker Feeder Breakers Maximum Number 1-Pole or 2-Pole Maximum Amps Single Phase 5 7.5 10 MPZ5S( )F MPZ7S( )F MPZ10S( )F $2314. 2704. 2938. 2-5% FCBN 2-5% FCBN 2-5% FCBN 175 200 215 32.7 32.7 32.7 12.0 12.0 12.0 11.9 11.9 11.9 FAL24040 FAL24060 FAL24080 40A 60A 80A FAL26015 FAL26015 FAL26020 15 A 15 A 20 A QO-230 QO-240 QO-260 30 A 40 A 60 A 6 or 3 8 or 4 10 or 5 20 30 40 15 25 MPZ15S( )F MPZ25S( )F 3814. 5691. 2-5% FCBN 2-5% FCBN 390 390 42.9 42.9 17.4 17.4 13.5 13.5 Q2L2125 Q2L2200 125A 200A FAL26030 FAL26050 30 A 50 A QO-280 QO-2125 80 A 125 A 16 or 8 24 or 12 60 100 Maximum Number 1-Pole or 3-Pole Three Phase TRANSFORMERS 15 22.5 30 MPZ15T( )F MPZ22T( )F MPZ30T( )F $6005. 7440. 9131. 2-5% FCBN 2-5% FCBN 2-5% FCBN 710 725 755 44.6 44.6 44.6 27.4 27.4 27.4 13.6 13.6 13.6 q Catalog Numbers shown in bold type are available from Distribution Center. f Dimensions – DO NOT use for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. To Complete Catalog Number: FAL34080 Q2L3125 Q2L3150 80A 125A 150A FAL36020 FAL36035 FAL36045 QO-360 QO-380 QO-3100 60 A 80 A 100 A 12 or 4 18 or 6 24 or 8 40 60 80 Special Voltage Codes Code Primary Voltage Secondary Voltage 240 600 208 120/240 120/240 120/240 240s 600s 208Y/120 208Y/120 Single Phase 62 4 60 1. Select the voltage required from chart. 12 20 A 35 A 45 A 2. Insert the voltage code number in place of the ( ) in the catalog number. Three Phase 11 7 QO, POWER-ZONE and QWIK-GARD are Registered Trademarks of Square D Company or related companies. For additional information, reference Bulletin No. 7440BR9401. 12-10 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type Open Core and Coil Class 7400 B C Open Core and Coil Transformers Designed for General Applications for 600 V and Below Units are designed with 220°C Insulation, Aluminum windings, top terminations, compact design to save space, UL component recognized, and available in single phase 5 to 75 kVA and three phase 3 to 112.5 kVA. We also have single phase units designed to meet EN 60742 and units are CE compliant and carry the CE mark 6.7 to 25 kVA. A Single Phase Open Core and Coil Transformers – D 240 X 480 V Primary 120/240 V Secondary 60 Hz E Figure 1 Catalog Number Price Degree C Temp. Rise Full Capacity Taps 5 7.5 10 15 5S1HFOC 7S1HFOC 10S1HFOC 15S1HOC $1366. 1458. 1617. 1755. 115 115 115 150 none none none none 25 37.5 50 75 25S3HOC 37S3HOC 50S3HOC 75S3HOC 2061. 2745. 3341. 4529. 150 150 150 150 6-2.5% 2+4- a 6-2.5% 2+4- a 6-2.5% 2+4- a 6-2.5% 2+4- a kVA C A Dimensions (Inches)f A B Weight Figure (lbs) C D E 8.0 9.0 8.0 9.0 8.0 9.0 14.5 14.0 11.0 14.25 14.25 12.5 8.0 8.0 8.0 13.0 8.0 8.5 8.5 8.5 66 80 100 110 1 1 1 2 14.5 19.0 19.0 19.0 12.5 16.0 17.0 17.0 13.0 13.0 13.0 13.0 8.5 11.0 13.5 13.5 120 230 260 565 2 2 2 2 14.0 16.5 18.0 28.0 a When 240 volt primary taps are 3-5% 1+ and 2-. f Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. Three Phase Open Core and Coil Transformers D E B Figure 2 C kVA Catalog Number Price Degree C Temp. Rise A B C 3T( )HFOC 6T( )HFOC 9T( )HFOC 15T( )HOC $1057. 1212. 1630. 1921. 115 115 115 150 8.0 9.5 13.0 13.0 9.0 10.5 18.0 18.0 6.5 8.5 12.5 12.5 7.0 8.25 16.0 16.0 30 45 75 112.5 30T( )HOC 45T( )HOC 75T( )HOC 112T( )HOC 2700. 3250. 4895. 6519. 150 150 150 150 14.0 14.5 19.5 19.5 18.0 18.0 21.0 21.0 12.5 15.0 16.0 19.0 16.0 16.0 16.0 16.0 A D B Figure 3 E Weight (lbs) Figure 2.38 2.75 4.0 8.5 45 80 120 120 3 170 260 365 565 3 D 3 6 9 15 8.5 8.5 11.0 11.0 Voltages Primary Secondary Full Capacity Taps 12 240 208Y/120 4-2.5% 2+2- 3 480 208Y/120 6-2.5% 2+4- 8 600 208Y/120 4-2.5% FCBN Voltage Code E Dimensions (Inches) f To Complete Catalog Number: 1. Select the voltage required from chart. 2. Insert the voltage code number in place of the ( ) in the catalog number. C Single Phase Open Core and Coil Transformers, Units comply with CE specification EN 60-742 These models are designed to accommodate voltage systems worldwide. 190/200/208/220x380/400/416/440 V Primary 110/220 V Secondary 50/60 Hz – UL Listed. A kVAc 6.7 D E B Price Degree C Temp. Rise A Dimensions (Inches) f B C D E Slot Weight (lbs) Figure EN6S67HFOC $1886. 115 10.0 9.0 11.25 8.0 9.12 .44 X .88 88 4 16 EN16S67HOC 2272. 150 16.5 15.0 12.50 13.0 4.50 .56 X 1.0 130 5 25 EN25S67HOC 2667. 150 17.5 15.0 12.50 13.0 4.50 .56 X 1.0 225 5 c kVA per EN 60-742 and UL 1561. f Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. TRANSFORMERS Figure 4 Catalog Number E E 12 A D C B Figure 5 3/00 PE2 Discount Schedule © 2000 Square D All Rights Reserved 12-11 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type Transformers Motor Starting Autotransformers Class 7400 Motor Starting Autotransformers with Open Core and Coil • 600 Volts and below • Class 220°C insulation • Available in 2-coil or 3-coil to match starter requirements • UL component recognized Two-Coil Motor Starting Autotransformers – 60 Hz, Medium Duty, Taps 50%/65%/80%/100% Horse Power 10 20 30 50 Catalog Number MSA10T( MSA20T( MSA30T( MSA50T( Price Dimensions A B 8.25 8.25 8.25 8.25 10.75 10.75 10.75 10.75 D E Weight (Pounds) Figure 12.0 12.0 12.0 12.0 9.0 9.0 9.0 9.0 7.5 7.5 7.5 7.5 45 45 65 65 A A A A C )H2 )H2 )H2 )H2 $1031. 1096. 1165. 1199. 75 100 125 150 MSA75T( )H2 MSA100T( )H2 MSA125T( )H2 MSA150T( )H2 1535. 1664. 2019. 2187. 9.5 9.5 11.0 11.0 12.25 12.25 14.5 14.5 11.0 11.0 11.5 11.5 9.0 9.0 9.0 9.0 7.5 7.5 7.5 7.5 95 95 125 125 A A A A 200 250 300 400 MSA200T( MSA250T( MSA300T( MSA400T( 2656. 3087. 3464. 4138. 11.0 14.25 14.25 18.5 14.5 17.0 17.0 19.5 11.5 12.25 12.25 13.37 9.0 9.0 9.0 17.5 7.5 9.0 9.0 11.5 145 160 180 225 A A A A )H2 )H2 )H2 )H2 Voltage Code Primary Voltage 200 208 201 240 202 480 203 600 C A D E 7/16" Dia. Mounting Holes (4) (10 Hp–50 Hp) 9/16" Dia. Mounting Holes (4) (75 Hp–400 Hp) B Figure A Three-Coil Motor Starting Autotransformers – 60 Hz, Medium Duty, Taps 50%/65%/80%/100% Horse Power TRANSFORMERS 10 20 30 50 Catalog Number MSA10T( MSA20T( MSA30T( MSA50T( Price Dimensions A B C D E Weight (Pounds) Figure 7.0 7.0 7.25 7.25 9.0 9.0 9.0 9.0 4.0 4.0 6.0 6.0 37 37 55 85 B B B B )H3 )H3 )H3 )H3 $1031. 1096. 1165. 1199. 7.5 7.5 7.5 7.5 10.5 10.5 13.0 13.0 75 100 125 150 MSA75T( )H3 MSA100T( )H3 MSA125T( )H3 MSA150T( )H3 1535. 1664. 2019. 2187. 12.0 12.0 12.0 14.0 14.5 14.5 14.5 15.5 9.5 9.5 9.5 10.0 9.0 9.0 9.0 9.0 7.25 7.25 7.25 7.5 85 85 135 135 B B B B 200 250 300 400 MSA200T( MSA250T( MSA300T( MSA400T( 2656. 3087. 3464. 4138. 14.0 14.0 14.0 14.75 15.5 15.5 15.5 18.25 10.0 10.5 10.5 12.0 9.0 9.0 9.0 9.0 7.5 7.62 9.12 9.12 135 145 210 230 B B B B )H3 )H3 )H3 )H3 Voltage Code Primary Voltage 200 208 201 240 202 480 203 600 B C A To Complete Catalog Number: 1. Select the voltage required from chart. 2. Insert the voltage code number in place of the ( ) in the catalog number. 12 E 1/2 x 7/8" Mounting Slots (4) D Figure B 12-12 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Industrial Control Transformers Class 9070 Triple Rated Voltage Codes k The Type T unit is designed for the global market and is the best choice when size and cost are of concern. This is our most popular and complete offering of industrial control transformers. Also available are the Type TF units with factory installed primary and secondary fuse blocks. The Type T and TF offering is 50/60 Hz rated and includes customer installable accessories such as FINGERSAFE® covers, fuse pullers, fuse blocks, and fuse clips. As part of the Type T designs are MultiTap ™ units having a variety of primary voltages on just one transformer. Our new Universal Control Transformer will provide 120 V, or near 120 V, power from all common primary voltages, 208 through 600 V, and is listed as voltage code D50. k The Type E unit is our high regulation design with exceptional voltage regulation. These control transformers are constructed using traditional materials and manufacturing techniques. When exceptional regulation and very low temperature rise are an absolute necessity, choose the Type E units. Selection Guide 1. Determine inrush and sealed VA of each coil in the control circuit and VA of all other components 3. Total the inrush VA of all coils that are starting at the same time and all loads and coils that are running (using the regulation chart to give possible units to be used) 4. Take VA size from step two, go to standard VA size in chart. Make sure inrush VA from chart is greater than total VA from step three. (If not go to next larger VA size and repeat) If your supply voltage is stable and fluctuates less than 5% we recommend you use the 90% secondary voltage column. If your supply voltage is not stable and fluctuates more than 10% we recommend you use the 95% secondary voltage column. We recommend that you never use the 85% secondary voltage column since magnetic devices lose life expectancy if they are continuously started at 85% of rated voltage. Primary Voltage Secondary Voltage D1 240 x 480 230 x 460 220 x 440 120 115 110 D5 600 575 550 120 115 110 D12 480 460 440 240 230 220 D24 120 115 110 120 115 110 D31 240 x 480 230 x 460 220 x 440 120/240 115/230 110/220 D32 240/480/600 230/460/575 220/440/550 99/120 95/115 91/110 D37 600 575 550 120/240 115/230 110/220 D50 240/416/480/600 230/400/460/575 220/380/440/550 208/500 99/120/130 95/115/125 91/110/120 85/100/110 D55 120 x 240 115 x 230 110 x 220 120/240 115/230 110/220 D62 600 575 550 240 230 220 D95 208/240/480 200/230/460 220/440 120 115 110 Regulation Chart for Type T Inrush VA @ 20% power factor VA 25 50 75 100 150 221 193 271 339 666 298 266 396 499 893 375 339 520 659 1120 171 151 210 266 529 240 215 318 404 731 311 282 430 549 942 200 250 300 350 500 588 1416 1634 1894 3197 815 1910 2184 2592 4104 1041 2388 2709 3261 4981 459 1057 1194 1392 2374 659 1494 1681 2005 3195 866 1936 2169 2621 4019 750 1000 1500 2000 3000 5000 3770 6587 19324 31384 26539 53111 5515 9079 23983 38777 39934 85265 7231 11430 28607 46161 52713 116277 2887 4706 15066 24794 19355 39368 4391 6886 19361 31630 30721 66309 5945 9051 23756 38667 42216 93882 Regulation Chart for Type E Inrush VA @ 20% power factor VA Inrush VA @ 40% power factor 95% Secondary 90% Secondary 85% Secondary 95% Secondary 90% Secondary 85% Secondary Voltage Voltage Voltage Voltage Voltage Voltage 25 50 75 100 150 95 164 387 479 755 ... 213 487 606 1177 146 277 622 770 1532 60 123 284 346 567 ... 168 375 463 930 119 225 798 613 1252 200 250 300 350 500 1260 1530 2030 2920 4230 1883 2327 2981 4586 5984 2419 2995 3800 5981 7707 910 1115 1455 2180 3120 1462 1811 2290 3637 4661 1950 2419 3038 4903 6229 750 1000 1500 2000 3000 5000 7430 10300 19200 27750 31800 86100 11460 16873 30042 45194 82333 148768 14736 21734 39217 60022 108205 202077 5380 7450 14500 21750 26750 72600 8907 13145 23859 36901 66072 126887 11891 17571 32179 50334 89509 175552 Listing For complete technical specification and selection data use the Square D Fax-on-Demand system. Dial 1-800-557-4556, follow prompts, and request document code 1348, or order catalog 9070CT9901. Inrush VA @ 40% power factor 95% Secondary 90% Secondary 85% Secondary 95% Secondary 90% Secondary 85% Secondary Voltage Voltage Voltage Voltage Voltage Voltage File Type UL E61239 cUL E61239 T1500-T5000 CSA LR37055, Guide 184-N-90 T25-T1000, EO17-EO11 947923, EN 60742/01.89 (TUV ref: 00941-RAG/sg E9371495E01) T25-T200 9579078, EN 60742/01.89 (TUV ref: 00941-RAG/sg E9471921.02E01) T250-T1000 9579078, EN 60742/01.89 (TUV ref: 00941-RAG/sg E9471921.02E01) T1500-T5000 EN (CE) T25-T5000, EO17-EO11 TRANSFORMERS 2. Total all sealed VA of all operating coils and other loads VA (Determines minimal VA size required for the circuit) Voltage Code 12 Square D manufactures two types of industrial control transformers – a global type and a high regulation type. FINGERSAFE is a Registered Trademark of Square D Company or related companies. MultiTap is a Trademark of Square D Company or related companies. 3/00 © 2000 Square D All Rights Reserved 12-13 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Industrial Control Transformers Class 9070 Key to Price Column Headings Voltage Code Primary Voltages Secondary Voltages Key for Dimensions & Accessory Square D manufactures a wide variety of voltage combinations for control transformers. The voltage combinations are expressed as “Voltage Codes” and these codes are embedded within the catalog number of the transformer. Standard codes are listed, if the voltage combination you require is not listed, call your Square D Distributor for assistance. Type T D1a D31a 240 x 480 240 x 480 120 120/240 I I D5a 600 120 I D37a 600 120/240 I D24a 120 120 I D55a 120 x 240 120/240 I D3 208 120 I D4 277 120 I D51 208/277 120 I D60 277 120/240 I n/a $ 57.00 60.00 63.00 83.00 n/a $ 41.00 49.70 55.00 70.00 n/a $142.00 148.00 149.00 158.00 n/a $142.00 148.00 149.00 158.00 n/a $142.00 148.00 149.00 158.00 n/a $ 41.00 49.70 55.00 70.00 n/a $ 41.00 49.70 55.00 70.00 n/a $142.00 148.00 149.00 158.00 n/a $142.00 148.00 149.00 158.00 62.00 72.00 80.00 85.00 106.00 107.00 113.00 132.00 138.00 155.00 89.00 110.00 113.00 131.00 143.00 216.00 217.00 219.00 220.00 227.00 216.00 217.00 219.00 220.00 227.00 216.00 217.00 219.00 220.00 227.00 89.00 110.00 113.00 131.00 143.00 89.00 110.00 113.00 131.00 143.00 216.00 217.00 219.00 220.00 227.00 216.00 217.00 219.00 220.00 227.00 147.00 178.00 254.00 309.00 429.00 721.00 215.00 254.00 372.00 413.00 677.00 916.00 202.00 254.00 356.00 413.00 582.00 916.00 255.00 271.00 390.00 423.00 724.00 916.00 255.00 271.00 390.00 423.00 724.00 916.00 255.00 271.00 390.00 423.00 724.00 916.00 202.00 254.00 356.00 413.00 582.00 916.00 202.00 254.00 356.00 413.00 582.00 916.00 255.00 271.00 390.00 423.00 724.00 916.00 255.00 271.00 390.00 423.00 724.00 916.00 UL/CSA/ NOM VA CE VA Type 25 50 75 100 150 25 50 75 100 150 T25 T50 T75 T100 T150 $ 33.50 35.30 41.80 46.90 50.00 200 250 300 350 500 200 160 200 250 300 T200 T250 T300 T350 T500 750 1000 1500 2000 3000 5000 500 630 1000 1500 2000 3000 T750 T1000 T1500 T2000 T3000 T5000 Type T D2 240 x 480 24 I D59 240 x 480 12/24 I D13 120 12/24 I D23 120/240 24 I D54 120/240 12/24 I D14 208 24 I D25 277 24 I D36 600 12/24 I $ 41.00 49.70 55.00 70.00 89.00 $142.00 148.00 149.00 158.00 216.00 $ 41.00 49.70 55.00 70.00 89.00 $ 41.00 49.70 55.00 70.00 89.00 $142.00 148.00 149.00 158.00 216.00 $ 41.00 49.70 55.00 70.00 89.00 $142.00 148.00 149.00 158.00 216.00 $142.00 148.00 149.00 158.00 216.00 T250 T300 T350 T500 T750 q 110.00 113.00 131.00 143.00 202.00 217.00 219.00 220.00 227.00 255.00 110.00 113.00 131.00 143.00 202.00 110.00 113.00 131.00 143.00 202.00 217.00 219.00 220.00 227.00 255.00 110.00 113.00 131.00 143.00 202.00 217.00 219.00 220.00 227.00 255.00 217.00 219.00 220.00 227.00 255.00 T1000 q 254.00 271.00 254.00 254.00 271.00 254.00 271.00 271.00 UL/CSA/ NOM VA CE VA 50 75 100 150 200 50 75 100 150 200 T50 T75 T100 T150 T200 250 300 350 500 750 160 200 250 300 500 1000 630 Type q See Control Transformer Catalog: 9070CT9901 for Dimensions different than digest Type T UL/CSA/NOM VA CE VA Type D15 240 x 480 24/120 I D12a 480 240 I D22 480 277 I D62a 600 240 I 50 75 100 150 200 50 75 100 150 200 T50 T75 T100 T150 T200 $ 41.00 49.70 63.00 70.00 89.00 $ 41.00 49.70 55.00 70.00 89.00 $142.00 148.00 149.00 158.00 216.00 $142.00 148.00 149.00 158.00 216.00 250 300 350 500 750 160 200 250 300 500 T250 T300 T350 T500 T750 113.00 132.00 138.00 155.00 215.00 110.00 113.00 131.00 143.00 202.00 217.00 219.00 220.00 227.00 255.00 217.00 219.00 220.00 227.00 255.00 1000 1500 2000 3000 5000 630 1000 1500 2000 3000 T1000 T1500 T2000 T3000 T5000 254.00 372.00 413.00 677.00 916.00 254.00 356.00 413.00 582.00 916.00 271.00 390.00 423.00 724.00 916.00 271.00 390.00 423.00 724.00 916.00 TRANSFORMERS a See Page 12-13 for triple ratings on this voltage code. 12 How to Order: To Order Specify: k Class Number k Type Number k Voltage Code Catalog Number Class Type Voltage Code 9070 T500 D1 FINGERSAFE is a Registered Trademark of Square D Company or related companies. 12-14 © 2000 Square D All Rights Reserved CP8 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Industrial Control Transformers Class 9070 Type T MultiTap™ UL/CSA/NOM VA CE VA Type D18 208/277/380 95/115 II D20 208/230/460 115 II D95 a 208/240/480 120 II D32 a 230/460/575 95/115 II D33 380/400/415 115/230 I D50 a 240/416/480/600 99/120/130 IV D19 208/240/277/380/480 24 III D52 380/400/415 12/24 I 50 50 T50 $ 57.00 $ 57.00 $157.00 $ 57.00 $ 57.00 $ 96.00 $ 41.00 $157.00 75 75 T75 60.00 60.00 158.00 60.00 60.00 103.00 49.70 158.00 100 100 T100 63.00 63.00 168.00 63.00 63.00 106.00 55.00 168.00 150 150 T150 83.00 83.00 235.00 83.00 83.00 111.00 70.00 235.00 200 200 T200 107.00 107.00 234.00 107.00 107.00 127.00 89.00 234.00 250 160 T250 113.00 113.00 237.00 113.00 113.00 138.00 110.00 237.00 300 200 T300 132.00 132.00 247.00 132.00 132.00 151.00 113.00 247.00 350 250 T350 138.00 138.00 287.00 138.00 138.00 156.00 131.00 287.00 500 300 T500 155.00 155.00 290.00 155.00 155.00 199.00 143.00 290.00 750 500 T750 q 215.00 215.00 320.00 215.00 215.00 231.00 202.00 320.00 1000 630 T1000 q 254.00 254.00 409.00 254.00 254.00 302.00 254.00 409.00 a See page 12-13 for triple ratings on this voltage code. q See Control Transformer Catalog: 9070CT9901 for Dimensions different than Digest. Type Dimension Key A B C Dq E F Slots Fig. I II III IV IN mm IN mm IN mm IN mm IN mm IN mm IN mm T25 & T50 T25 ... ... 3.09 78.5 3.00 76.2 2.58 65.5 3.84 97.5 2.00 50.8 2.50 63.5 .20x.38 5.1x9.7 1 ... ... T25 ... 4.00 101.6 3.43 87.1 2.64 67.0 4.80 121.9 2.00 50.8 2.50 63.5 .20x.48 5.1x12.2 2 ... ... T50 T50 4.19 106.4 3.43 87.1 2.89 73.4 4.99 126.7 2.38 60.5 2.81 71.4 .20x.48 5.1x12.2 2 T75 & T100 T50 ... ... 3.34 84.8 3.38 85.8 2.89 73.4 4.09 103.9 2.38 60.5 2.81 71.4 .20x.48 5.1x12.2 1 ... ... 3.59 91.2 3.75 95.3 3.20 81.3 4.34 110.2 2.88 73.2 3.13 79.5 .20x.38 5.1x9.7 1 T75 & T100 T75 4.88 124.0 3.75 95.3 3.20 81.3 5.68 144.2 2.88 73.2 3.13 79.5 .20x.38 5.1x9.7 2 T150 & T200 T75, T100 & T150 ... ... T250 ... T150 T100 5.25 133.4 3.75 95.3 3.25 82.6 6.05 153.6 2.88 73.2 3.13 79.5 .20x.38 5.1x9.7 2 T300 T200 T200 T150 4.70 119.4 4.50 114.3 3.80 96.5 5.50 139.7 2.56 65.0 3.75 95.3 .20x.38 5.1x9.7 2 T350 T250 & T300 T250 T200 & T250 5.09 129.3 4.50 114.3 3.80 96.5 5.89 149.6 3.00 76.2 3.75 95.3 .20x.38 5.1x9.7 2 T500 T350 T350 & T300 T300 5.46 138.7 4.50 114.3 3.80 96.5 6.26 159.0 3.56 90.4 3.75 95.3 .28x.56 7.1x14.2 2 T750 T500 T500 T350 & T500 5.66 143.8 5.25 133.4 4.43 112.5 6.46 164.0 3.43 87.1 4.38 111.3 .28x.56 7.1x14.2 2 T1000 T750 T750 T750 6.04 153.4 5.25 133.4 4.43 112.5 6.84 173.7 4.31 109.5 4.38 111.3 .28x.56 7.1x14.2 2 T1500 T1000 T1000 T1000 5.81 147.6 7.06 179.3 6.16 156.5 6.61 167.9 4.13 104.9 5.81 147.6 .28x.56 7.1x14.2 2 T2000 T1500 T1500 T1500 7.04 178.8 7.06 179.3 6.16 156.5 7.84 199.1 4.56 115.8 5.81 147.6 .28x.56 7.1x14.2 2 T3000 T2000 T2000 T2000 6.86 174.2 9.00 228.6 8.46 214.9 7.26 184.4 4.63 117.6 7.63 193.8 .44x.69 11.2x17.5 3 T5000 T3000 T3000 T3000 8.73 221.7 9.00 228.6 8.46 214.9 9.13 231.9 6.56 166.6 7.63 193.8 .44x.69 11.2x17.5 3 q Dimension with FINGERSAFE® Covers D D B A Accessories FINGERSAFE® Covers (not supplied with unit) B A Type Accessory Keyq Type C C I Description Price 2 covers per kit $6.60 N/A 2 covers per kit 9.00 T25-T5000 2 covers per kit 9.20 II III, IV FSC-1 T25-T200 T25-T100 N/A FSC-2 T250-T5000 T150-T5000 FSC-23 N/A N/A q Kits must be ordered separately. Also supplied in bulk packages of 100 individual covers. Add “B” to Type number (available only on FSC-1B and FSC-2B). F E D E Figure 2 A B Fuse Pullers (use on TF and FB accessory) Catalog Price 9070FP-1 $9.50 Jumper Kits Catalog Number C Type Accessory Key Description Price Two jumpers per bag Minimum order 30033-027-54 T250-T5000 T200-T3000 T25-T3000 of 50 kits $1.60 I 30033-027-53 T25-T200 II T25-T150 III, IV N/A 1.60 TRANSFORMERS F 12 Figure 1 NOTE: Jumpers are supplied with voltage codes that require them. If additional kits are required, order per above chart. F Figure 3 E FINGERSAFE is a Registered Trademark of Square D Company or related companies. MultiTap is a Trademark of Square D Company or related companies. 3/00 CP8 Discount Schedule © 2000 Square D All Rights Reserved 12-15 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Industrial Control Transformers Class 9070 Type TF: Factory Installed Primary and Secondary Fuse Blocks B D A D1 a 240 X 480 120 I 50 50 TF50 $ 50.00 75 75 TF75 56.00 100 100 TF100 61.00 150 150 TF150 65.00 200 200 TF200 77.00 250 160 TF250 87.00 300 200 TF300 95.00 350 250 TF350 100.00 500 300 TF500 120.00 750 500 TF750 161.00 1000 630 TF1000 194.00 1500 1000 TF1500 269.00 2000 1500 TF2000 324.00 a See Page 12-13 for triple ratings on this voltage code. UL/CSA VA G C F E CE VA D2 240 x 480 24 I $ 56.00 ... 70.00 84.00 ... ... 129.00 ... 158.00 ... ... ... ... Type D3 208 120 I $ 56.00 ... 70.00 84.00 ... ... 129.00 ... 158.00 ... ... ... ... D5 a 600 120 I $ 56.00 ... 70.00 84.00 ... ... 129.00 ... 158.00 ... ... ... ... D20 208/230/460 115 II $ 82.00 ... 89.00 109.00 134.00 ... 166.00 ... 185.00 ... ... ... ... D23 120/240 24 I $ 56.00 64.00 70.00 84.00 89.00 116.00 129.00 131.00 158.00 ... ... ... ... Dimensions–Type TF Only I 25 VA ... 50 VA ... 75 VA ... ... 100 VA ... 150 VA 200 VA 250 VA 300 VA 350 VA ... ... 500 VA ... 750 VA 1000 VA 1500 VA 2000 VA VA Key II ... ... 25 VA ... 50 VA 75 VA ... ... ... 100 VA 150 VA ... 200 VA 250 VA 300 VA ... 350 VA ... 500 VA 750 VA 1000 VA 1500 VA III ... 25 VA ... 50 VA ... ... 75 VA ... 100 VA ... ... 150 VA 200 VA 250 VA ... 300 VA ... 350 VA 500 VA 750 VA 1000 VA 1500 VA Figure A B C Dq E F Gf SLOT 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.09 4.00 3.09 4.19 3.34 3.59 4.88 3.34 4.88 3.59 3.59 5.25 4.70 5.09 5.09 5.46 5.46 5.46 5.66 6.04 5.81 7.04 3.00 3.43 3.00 3.43 3.38 3.75 3.75 3.38 3.75 3.75 3.75 3.75 4.50 4.50 4.50 4.50 4.50 4.50 5.25 5.25 7.06 7.06 4.00 4.00 4.00 4.25 4.25 4.55 4.55 4.25 4.55 4.55 4.55 4.55 5.10 5.10 5.10 5.10 5.10 5.10 5.73 5.73 7.46 7.46 3.84 4.80 3.84 4.99 4.09 4.34 5.68 4.09 5.68 4.34 4.34 6.05 5.50 5.89 5.89 6.26 6.26 6.26 6.46 6.84 6.61 7.84 2.00 2.00 2.00 2.38 2.38 2.88 2.88 2.38 2.88 2.88 2.88 2.88 2.56 3.00 3.00 3.56 3.56 3.56 3.43 4.31 4.13 4.56 2.50 2.50 2.50 2.81 2.81 3.13 3.13 2.81 3.13 3.13 3.13 3.13 3.75 3.75 3.75 3.75 3.75 3.75 4.38 4.38 5.81 5.81 4.20 4.20 4.20 4.45 4.45 4.75 4.75 4.45 4.75 4.75 4.75 4.75 5.30 5.30 5.30 5.30 5.30 5.30 5.93 5.93 7.66 7.66 .20 x .38 .20 X .48 .20 x .38 .20 X .48 .20 X .48 .20 x .38 .20 x .38 .20 X .48 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .20 x .38 .28 X .56 .28 X .56 .28 X .56 .28 X .56 q Dimensions with FINGERSAFE® covers installed. f Dimensions with fuse pullers installed. Field Installed Fuse Options Field-Installable Secondary Fuse Clips Primary and Secondary Fusing Type Type Accessory Key I II III, IV FB-3A 25-200 25-150 N/A FB-3B 2502000 2001500 251500 Description Price Three pole fuse block for primary fusing, accomodates 1-1/2" x $26.40 13/32" midget fuse (2 rejection and 1 non-rejection) Three pole fuse block for primary and secondary fusing, accomodates 1-1/2" x 13/32" midget fuse 26.40 (2 rejection and 1 non-rejection) Primary Fusing Type FB-2A 25-200 25-150 N/A TRANSFORMERS 2001500 251500 Description Two pole fuse block for primary and secondary fusing, accommo- $22.70 dates 1-1/2" x 13/32" midget fuse (2 rejection) Two pole fuse block for primary fusing, accomodates 1-1/2" x 13/ 22.70 32" midget fuse (2 rejection) D1:240 x 480-120 12 I CE VA 50 100 150 160 300 500 Catalog Number 9070T50D1SF41 9070T100D1SF41 9070T150D1SF41 9070T250D1SF41 9070T500D1SF41 9070T750D1SF41 II Price $ 40.30 52.00 55.00 79.00 113.00 154.00 Description III, IV Price SF25A 25-200 25-150 N/A Secondary fuse block accommodates 1-1/4" x 1/4" fuse $6.60 SF25B 2502000 Secondary fuse block accommodates 1-1/4" x 1/4" fuse 6.60 Secondary fuse clip accommodates 1-1/2" x 13/32" midget fuse 5.40 Secondary fuse clip accommodates 1-1/2" x 13/32" midget fuse 5.40 2001500 251500 SF41Ac 25-200 25-150 N/A 2002000 252000 Price Factory Installed Secondary Fuse Clips UL/CSA VA 50 100 150 250 500 750 Type Accessory Key SF41Bc N/A Type Accessory Key I II III, IV FB-2B 2502000 Type FB-1A 25-200 25-150 N/A One pole fuse block for secondary fusing, accomodates 1-1/2" 15.80 x 13/32" midget fuse (1 nonrejection) FB-1B 2502000 One pole fuse block for secondary fusing, accomodates 1-1/2" 15.80 x 13/32" midget fuse (1 nonrejection) 2001500 251500 c SF41 can be installed on the following voltage codes: D1, D5, D24, D3, D4, D51, D2, D23, D14, D25, D20, D95, D19. How to Order: To Order Specify: k Class Number k Type Number k Voltage Code k Field Fuse Option Catalog Number Class Type Voltage Code 9070 TF500 D1 9070 FB-3B FINGERSAFE is a Registered Trademark of Square D Company or related companies. 12-16 © 2000 Square D All Rights Reserved CP8 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Proof date: 12/13/99, 2:59 PM Industrial Control Transformers Class 9070, 9991 Type E VA Type Make changes: Initials _______________ Date: _____________ Type EO3D1 Dimensions - See Figure 4 Weight (lbs.) 60 Hz 50 Hz A B C E F Slot EO17 EO1 EO18 25 50 75 25 35 75 3.31 3.31 3.78 3.00 3.00 3.38 2.50 2.50 2.81 1.75 2.00 2.19 2.50 2.50 2.81 .20 x .38 .20 x .38 .20 x .38 1.9 2.2 3.5 EO2 EO3 EO4 100 150 300 70 120 240 3.78 4.44 5.56 3.38 3.75 4.50 2.81 3.13 3.75 2.38 2.88 3.25 2.81 3.13 3.75 .20 x .38 .20 x .38 .20 x .38 3.8 6.0 10.5 EO16 EO51 EO61 350 500 750 280 400 500 6.19 6.56 7.94 4.50 5.25 5.25 3.75 4.38 4.38 3.81 3.81 5.13 3.75 4.38 4.38 .20 x .38 .28 x .41 .28 x .41 13.2 17.2 24.5 EO71 EO81 EO91 1000 1500 2000 900 1300 1800 7.94 8.59 9.22 6.00 7.06 7.06 5.00 6.03 6.03 4.75 5.88 6.50 5.00 5.81 5.81 .28 x .63 .44 x .69 .44 x .69 30.5 45.0 56.0 EO10 EO11 3000 5000 3000 5000 9.44 12.06 9.00 9.00 8.38 8.38 5.88 8.50 7.63 7.63 .44 x .69 .44 x .69 72.0 115.0 Type E Stocked Voltages B A C F VA Type E Figure 4 60 Hz Stocked Voltage Codes 50 Hz Price EO17 25 25 D1, D2, D3 $ 35.80 EO1 50 35 D1, D2, D7 45.00 EO18 75 75 D1, D2 52.00 EO2 100 70 D1, D2 62.00 EO3 150 120 D1, D7 EO4 300 240 D1, D5, D7 126.00 EO16 350 280 D1, D2 134.00 EO51 500 400 D1, D5, D6 152.00 EO61 750 500 D1, D5 215.00 EO71 1000 900 D1, D5 247.00 EO81 1500 1300 D1 379.00 EO91 2000 1800 D1 459.00 EO10 3000 3000 D1 662.00 EO11 5000 5000 D1 1009.00 70.00 Transformers with Leads OK TO PRINT: Initials: _______________ Date_____________ Transformers with leads, instead of screw terminals, are available. See the following chart for VA sizes and voltage combinations. Consult your nearest Square D/Schneider Electric sales office for further details. Lead length is 25". Type EL and KL with Leads Type VA Voltage Price EL1D9 EL2D9 EL3D9 KL300D9 50 100 150 300 480-120 480-120 480-120 480-120 $ 70.00 94.00 107.00 174.00 Class 9070 Type EL, KL Dimensions – See Figure 5 Type Weight (lbs.) A B C E F G H EL1 2.2 25⁄8 3 21⁄2 2 21⁄2 13⁄64 3⁄8 EL2 3.8 3 33⁄8 213⁄16 23⁄8 213⁄16 13⁄64 3⁄8 EL3 6.0 35⁄8 33⁄4 31⁄8 27⁄8 31⁄8 13⁄64 3⁄8 KL300 8.0 31⁄2 41⁄2 33⁄4 29⁄16 33⁄4 13⁄64 3⁄8 Separate NEMA Type 1 Enclosures for Transformers Figure 5 For Use With UE7 EO1, EO17, T50 LG1 EO2, EO3, EO4, EO15, EO16, EO18, EO19, T75, T100, T150, T200, T250, T300, T350, T500 SDG4 EO51, EO61, T750, T1000, EO71 User must drill mounting holes. Refer to pages 13-105 and 13-106 for dimensions. How to Order: To Order Specify: 3/00 CP8 Discount Schedule Catalog Number Class Type Voltage Code 9070 E051 D1 © 2000 Square D All Rights Reserved 12 k Class Number k Type Number k Voltage Code TRANSFORMERS Class 9991 Type 12-17 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Transformer Disconnects Class 9070 Class 9070 Transformer Disconnect – Improved Design k Up To 34% Less Panel Space k UL Listed, File E137621 k CSA certified (NEMA Type 1 only), File LR37055 Transformer disconnects mount inside or outside a control system enclosure and provide power to auxiliary single-phase loads when the main three-phase disconnect is either “on” or “off.” The transformer disconnect is normally wired to the line side of the control panel's main disconnect. This convenient source of 120 V power can be used for auxiliary or isolated loads, such as panel lighting, portable power tools, and programmable controller equipment. The standard enclosure is a lockable NEMA Type 1 for general purpose applications. The disconnect switch is rated at 45 Amperes, 600 volts, and has an external handle mechanically interlocked with the enclosure cover. The handle can lock in the “off” position. There is also a standard fusible and grounded transformer secondary. Transformer Disconnects available in NEMA Type 1 Standard, NEMA Type 12 Standard, and NEMA Type 1 Mini. Primary fuse holders and secondary fuse holders for branch circuit protection are now standard, complying with National Electric Code requirements. NEMA Type 1 Mini Enclosure D1 = 240/480 V-120 V 230/460 V-115 V 220/440 V-110 V 50/60 Hz Transformer Continuous VA Catalog Numberq Price Enclosure Dimensions 100 250 500 MN100G0D1 MN250G0D1 MN500G0D1 $ 417. 464. 511. G0 G0 G0 NEMA Type 1 Standard Enclosure A B C D E F G H I J 10.3 10.3 10.3 2.0 2.0 2.0 2.65 2.65 2.65 11.3 11.3 11.3 7.0 7.0 7.0 7.81 7.81 7.81 15.25 15.25 15.25 2.09 2.09 2.09 .32 .32 .32 1.0 1.0 1.0 D1 = 240/480 V-120 V 230/460 V-115 V 220/440 V-110 V 50/60 Hz Transformer Continuous VA Catalog Numberq Price Enclosure Dimensions 250 500 750 SK250G1D1 SK500G1D1 SK750G1D1 $ 422. 464. 522. 1000 1500 2000 3000 SK1000G1D1 SK1500G2D1 SK2000G2D1 SK3000G2D1 686. 1015. 1154. 1464. A B C D E F G H I J G1 G1 G1 10.8 10.8 10.8 1.7 1.7 1.7 6.0 6.0 6.0 11.8 11.8 11.8 9.4 9.4 9.4 8.96 8.96 8.96 16.81 16.81 16.81 2.09 2.09 2.09 .32 .32 .32 1.0 1.0 1.0 G1 G2 G2 G2 10.8 13.8 13.8 13.8 1.7 1.7 1.7 1.7 6.0 10.0 10.0 10.0 11.8 14.8 14.8 14.8 9.4 13.4 13.4 13.4 8.96 12.21 12.21 12.21 16.81 23.06 23.06 23.06 2.09 2.09 2.09 2.09 .32 .32 .32 .32 1.0 1.0 1.0 1.0 NEMA Type 12 Standard Enclosuret D1 = 240/480 V-120 V 230/460 V-115 V 220/440 V-110 V 50/60 Hz Transformer Continuous VA Catalog Number Price Enclosure Dimensions 250 500 750 SK250A2D1 SK500A2D1 SK750A2D1 $1023. 1066. 1129. 1000 1500 2000 3000 SK1000A2D1 SK1500A2D1 SK2000A2D1 SK3000A2D1 1161. 1277. 1361. 1699. A B C D E F G H I J K A2 A2 A2 13.5 13.5 13.5 2.86 2.86 2.86 6.0 6.0 6.0 14.5 14.5 14.5 16.5 16.5 16.5 13.49 13.49 13.49 25.56 25.56 25.56 2.44 2.44 2.44 4.25 4.25 4.25 15.75 15.75 15.75 .32DIA .32DIA .32DIA A2 A2 A2 A2 13.5 13.5 13.5 13.5 2.86 2.86 2.86 2.86 6.0 6.0 6.0 6.0 14.5 14.5 14.5 14.5 16.5 16.5 16.5 16.5 13.49 13.49 13.49 13.49 25.56 25.56 25.56 25.56 2.44 2.44 2.44 2.44 4.25 4.25 4.25 4.25 15.75 15.75 15.75 15.75 .32DIA .32DIA .32DIA .32DIA q Catalog numbers shown in bold type are normally stocked items. t Rated NEMA Type 3R by adding form N3. D A B C ON E OFF TRANSFORMERS 1/2"- 3/4" Knockouts 90¡ I G J 12 F H 1/2"- 3/4" Conduit Enclosure Type G0, G1, G2 12-18 © 2000 Square D All Rights Reserved Enclosure Type A2 CP1 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Transformer Disconnects Class 9070 Special Voltage Codes (use adder) Standard Features k Sizes k Switch k Enclosure k Type TF Transformer k k k k 100 through 3000 VA – 600 V, 45 A 100,000 A Short Circuit Withstand Integrated Rating When Protected by Class CC Fuses. NEMA Type 1 – 230/460-115 V – Top-mounted Fuse Block – Accommodates Two Class CC Time Delay Primary Fuses and One Secondary Fuse 1-1/2" x 13/32" Knockouts Conveniently Located Ground Terminal External Mounting Flanges with Slotted Holes for “Hook and Hang” Mounting 90 degrees Access Cover Stop Voltage Code Primary Voltage Secondary Voltage D3 208 120 D4 277 120 D5 550 575 600 110 115 120 110 D6 380 D17 415 110 D24 110 115 120 110 115 120 Please contact your nearest Square D/Schneider Electric sales office for other voltages. Cross Reference Old Square D Number Old Square D Number New Square D Number SK5271M SK5271N SK250G1 SK250G1 MN100G0D1 MN250G0D1 SK5271Q,R SK5271S,J SK5271T,K SK250G1 SK500G1 SK750G1 SK250G1D1 SK500G1D1 SK750G1D1 SK5271U SK5271V SK5271W SK5271X SK1000G1 SK1500G2 SK2000G2 SK3000G2 SK1000G1D1 SK1500G2D1 SK2000G2D1 SK3000G2D1 Type SK transformer disconnects–UL Listed: File E137621: CSA certified: File LR37055. Factory Modifications For NEMA Type 1 t Factory Modification Forms Type TF control power transformer with top mounted fuse block provides wiring ease in minimal space. Units Stocked with Factory Modifications: 9070SK500G1D1F11 9070SK500G1D1G13 9070SK1000G1D1G13 G13q Duplex Receptacle, Door-Mounted $100.00 G0, G1, G2, A2 G14q Class A Ground Fault Protected Receptacle, Door-Mounted 222.00 G0, G1, G2, A2 G15q Twist-Lock Receptacle, Door-Mounted 159.00 G1, G2 G16q Two Duplex Receptacles, Door-Mounted 201.00 G2, A2 E23kc Electrostatically-Shielded Transformer 100.00 G0, G1, G2, A2 P1 “ON” Red Warning Pilot Light C 55°C Rise Transformer (standard on SK250G1) N3 Convert NEMA Type 12 to NEMA Type 3R 34.00 A2 F11c Additional Fusible Secondary Circuit 37.00 G0, G1, G2, A2 F30 Replace Standard 13/32" x 1-1/2" Class CC Primary Fuse Holders with 13/16" x 5" Primary Fuse Holders 80.00 G2, A2 Special Voltages (See Voltage Chart above) q k c t b Available on Enclosure Sizes b Price Adder Description 53.00 G1, G2, A2 106.00 G1, G2, A2 211.00 G1, G1, G2, A2 Not available with other receptacle options. Consult factory for inrush data. E23 and F11 not available together in Size 1 enclosure. Mini enclosure limited to only one modification, restricted to E23, F11, G13 or G14. Note: If either Form F30 or G16, or the combination of Forms E23 and F11 are ordered on SK250G1 through SK1000G1, the Size 2 enclosure must be supplied. Therefore, the catalog numbers change to SK250G2 through SK2000G2 and a list price adder of $106.00 will apply. How to Order: To Order Specify: Catalog Number Class Type VA Rating Enclosure(s) Voltage Code Form(s) 9070 SK 1000 G1 D1 P1 12 TRANSFORMERS k Class Number k Type Number k VA Rating k Enclosure k Voltage Code k Form(s) G13, G14, G15, G16 F30 - Not Shown on Drawing 3/00 CP1 Discount Schedule © 2000 Square D All Rights Reserved 12-19 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Instrument Transformers–600 Volt Class Voltage Transformers, Current Transformers Class 4210 Voltage Transformers k These voltage transformers are designed for line-to-line or line-to-ground connection on the primary voltage indicated. See the table below to determine the applicable configuration for proper system voltage indication. k Model 450R is designed for switchboard use. This model features high accuracy and burden capacity for excellent performance in metering and indication. k Model 460R is a compact, lightweight design, providing exceptional performance in indicating applications. k Model 470R is a compact, low cost design optimized for maximum accuracy and performace when used with POWERLOGIC® circuit monitors. UR/cUR Recognized. 60 Hz Model 450R MODEL 450R MODEL 460R Thermal Rating: 500 VA @ 30°C; 300 VA Thermal Rating: 150 VA @ 30°C: 100 VA @ 55°C. @ 55°C. Accuracy 0.3W. X.M & Y: 1.2 Z Accuracy 0.6W: 1.2 X Catalog Numberk Price Each MODEL 470R Thermal Rating: 150 VA @ 30°C: 100 VA @ 55°C. Accuracy 0.3W: 1.2 X Catalog Numberk System Voltage Winding Ratio Catalog Numberk Price Each 450R069 450R120 450R208 450R240 450R288 $301. 301. 301. 301. 301. 460R069 460R120 460R208 460R240 460R288 $225. 225. 225. 225. 225. 470R069 470R120 470R208 470R240 470R288 Price Each $248. 248. 248. 248. 248. 69/120Y 120/208Y 120/208Y 240/416Y 288/500Yq 0.58:1 1:1 1.73:1 2:1 2.4:1 450R300 450R380t 450R480 450R600 314. 345. 314. 314. 460R300 460R380t 460R480 460R600 232. 255. 232. 232. 470R300 470R380t 470R480 470R600 $256. 282. 256. 256. 300/520Y 220/380Y 480/480Yc 600/600Y 2.5:1 3.17:1 4:1 5:1 q Use on 277/480 wye systems c Use on 480 V delta systems t Designed for 50 Hz applications Model 460R Model 470R Current Transformers General Purpose Compact Units UR/cUR Recognized Window Size Catalog Numberk (without brackets) j Current Rating (Amperes) VA 60 Hz VA 400 Hz Accuracy (At Rated Current) Rating Factor 30°C Ambient Price Each 11⁄8" 2NR500 2NR600 2NR750 2NR800 2NR101 2NR121 2NR1250 2NR151 2NR201 2NR251 2NR301 50:5 60:5 75:5 80:5 100:5 120:5 125:5 150:5 200:5 250:5 300:5 1.0 1.0 1.5 1.5 2.0 2.5 2.5 2.5 2.5 2.5 2.5 2.0 2.0 3.0 3.0 4.0 5.0 5.0 5.0 5.0 5.0 5.0 = 2% = 2% = 2% = 2% = 1% = 1% = 1% = 1% = 1% = 1% = 1% 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 $27.60 27.60 27.60 27.60 27.60 27.60 27.60 27.60 27.60 27.60 27.60 19⁄16" 5NR101 5NR151 5NR201 5NR251 5NR301 5NR401 5NR501 5NR601 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 2.0 2.5 5.0 5.0 5.0 12.5 12.5 25.0 4.0 5.0 12.5 12.5 12.5 25.0 25.0 50.0 = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 32.50 32.50 32.50 32.50 32.50 35.30 35.30 35.30 19⁄16" 54R101 54R151 54R201 54R251 54R301 54R401 54R501 54R601 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 2.0 2.5 5.0 5.0 5.0 12.5 12.5 25.0 4.0 5.0 12.5 12.5 12.5 25.0 25.0 50.0 = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 34.40 34.40 34.40 34.40 34.40 38.20 38.20 38.20 21/4" 7RL500 7RL101 7RL151 7RL201 7RL251 7RL301 7RL401 7RL501 7RL601 7RL751 7RL801 7RL102 7RL122 7RL152 50:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 2.5 2.5 2.5 5.0 5.0 5.0 12.5 12.5 12.5 12.5 12.5 25.0 25.0 25.0 5.0 5.0 5.0 10.0 10.0 10.0 25.0 25.0 25.0 25.0 25.0 50.0 50.0 50.0 = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% = 1% 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 39.00 39.00 39.00 39.00 39.00 39.00 39.00 39.00 39.00 39.00 39.00 45.00 45.00 45.00 B A C Dimensions Model 450R 460R 470R A B C 6 43⁄4 43⁄4 71⁄8 41⁄2 41⁄2 57⁄8 37⁄8 37⁄8 Model 54R D TRANSFORMERS .20 Dia. Mtg. Hole (2) A H1 BEC k Catalog Numbers in bold type are normally stock j Mounting brackets on page 12-24. Dimensions (inches) 12 Model 2NR 5NR 54R 7RL A 1.13 1.56 1.56 2.25 B C D E 2.38 – .94 – 3.50 – 1.06 – 3.50 4.56 1.06 4.00 4.38 – 1.38 – For additional information including excitation curves, reference Bulletin 4210CT9701 or D-Fax ™ number 197 (Pages 1-20) and 201 (Pages 21-38). POWERLOGIC is a Registered Trademark of Square D Company or related companies. 12-20 © 2000 Square D All Rights Reserved PA1 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Instrument Transformers–600 Volt Class Torroidal Current Transformers Class 4210 Relay Class 115⁄16" 64R101 64R151 64R201 64R251 64R301 64R401 64R501 64R601 64R751 100:5 150:0 200:5 250:5 300:5 400:5 500:5 600:5 750:5 115⁄16" 66R101 66R151 66R201 66R251 66R301 66R401 66R501 66R601 66R751 B-0.1 B-0.2 B-0.5 B-0.9 B-1.8 Rating Factor 30°C Ambient – – – – – – – – – 1.2 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 2.4 1.2 1.2 0.6 0.6 0.6 0.3 0.3 0.3 – – 2.4 1.2 1.2 0.6 0.6 0.3 0.3 – – – – 2.4 1.2 0.6 0.6 0.6 – – – – – – – 1.2 0.6 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 $ 40.10 40.10 40.10 40.10 40.10 46.70 46.70 54.00 55.00 100:5 150:0 200:5 250:5 300:5 400:5 500:5 600:5 750:5 – – C10 C10 C10 C10 C20 C20 C20 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 – 2.4 2.4 1.2 1.2 0.6 0.6 0.3 0.3 – – – 2.4 2.4 1.2 0.6 0.6 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 75.00 75.00 75.00 75.00 75.00 85.00 85.00 94.00 97.00 211⁄32" 74R201 74R251 74R301 74R401 74R501 74R601 74R751 74R801 74R102 74R122 74R152 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 – – – – – – – – – – – 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.6 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 – 1.2 2.4 1.2 0.6 0.6 0.6 0.6 0.3 0.3 0.3 – – – – 1.2 1.2 1.2 1.2 0.6 0.6 0.6 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 55.00 55.00 55.00 55.00 55.00 55.00 59.00 58.00 63.00 70.00 74.00 211⁄32" 76R201 76R251 76R301 76R401 76R501 76R601 76R751 76R801 76R102 76R122 76R152 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 C10 C10 C10 C10 C10 C20 C20 C20 C20 C20 C20 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 1.2 0.6 0.6 0.6 0.3 0.3 0.3 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 85.00 85.00 85.00 85.00 85.00 85.00 85.00 85.00 108.00 112.00 131.00 4" 100R201 100R301 100R401 100R501 100R601 100R801 100R102 100R122 100R152 100R162 100R202 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 C10 C10 C20 C20 C20 C20 C50 C50 C50 C50 C50 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 110.00 110.00 110.00 110.00 110.00 110.00 137.00 137.00 160.00 160.00 160.00 4" 110R201 110R301 110R401 110R501 110R601 110R801 110R102 110R122 110R152 110R162 110R202 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 C20 C20 C20 C50 C50 C50 C100 C100 C100 C100 C100 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 156.00 156.00 156.00 156.00 156.00 177.00 192.00 192.00 207.00 207.00 207.00 53⁄4" 120R201 120R301 120R401 120R501 120R601 120R801 120R102 120R122 120R152 120R162 120R202 120R252 120R302 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 C10 C10 C20 C20 C20 C20 C20 C50 C50 C50 C50 C50 C50 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 122.00 122.00 122.00 122.00 122.00 127.00 139.00 139.00 150.00 150.00 150.00 177.00 177.00 81⁄8" 140R500 140R101 140R401 140R501 140R601 140R801 140R102 140R122 140R152 140R202 140R252 140R302 140R402 140R502 140R602 50:5 100:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 6000:5 – – C20 C20 C20 C50 C50 C100 C100 C100 C100 C100 C100 C100 C100 – – 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 1.0 256.00 256.00 256.00 256.00 256.00 256.00 275.00 275.00 324.00 324.00 324.00 324.00 344.00 406.00 484.00 Models 64R, 74R Models 66R, 76R Models 100R, 110R, 120R and 140R A B B C Dimensions (inches) Model 64R 66R 74R 76R 100R 110R 120R 140R A B C 115⁄16 115⁄16 211⁄32 211⁄32 4 4 53⁄4 81⁄8 43⁄16 43⁄16 411⁄16 411⁄16 7 7 81⁄2 11 11⁄2 31⁄16 15⁄8 31⁄4 21⁄8 27⁄8 21⁄8 3 ANSI Accuracy Classification — 60 Hz Metering Class For Ground Fault Sensing 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Price 12 Catalog k Current Window Number (without Rating Size brackets) (Amperes) j TRANSFORMERS Torroidal Current Transformers UR/cUR Recognized 25–400 Hz k Catalog numbers shown in bold letters are normally stocked items. j Mounting brackets on page 12-24. 3/00 PA1 Discount Schedule © 2000 Square D All Rights Reserved 12-21 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Instrument Transformers–600 Volt Class Torroidal Current Transformers, Shorting Terminal Blocks Class 4210 Torroidal Current Transformers UR/cUR Recognized 25–400 Hz Models 152R, 170R, 180R, 210R Window Size X1 A CL B HI 67⁄8" CL B C Dimensions (inches) Model A B C 152R 6.88 12.25 4.12 170R 4.25 6.75 1.31 180R 2.50 4.50 2.12 210R 6.25 9.50 2.87 41⁄4" Models 200R, 201R, 202R and 203R 8.50 1.0 1.0 3.25 X1 CL HI A 21⁄2" CL 4.62 21⁄2" 8.50 Modelt Dimension A (Inches) 200R 201R 202R 203R 2.50 3.50 4.50 5.25 21/2" t Base is included Shorting Terminal Blocks 3090TB4 3090TB6 Shorting Terminal Block (4-pole) Shorting Terminal Block (6-pole) $49.00 56.00 31/2" 12 TRANSFORMERS 41/2" 51/4" Catalog Numberk (without brackets)j 152R500 152R101 152R151 152R201 152R251 152R301 152R401 152R501 152R601 152R801 152R102 152R122 152R152 152R162 152R202 152R252 152R302 152R402 170R201 170R251 170R301 170R401 170R501 170R601 170R751 170R801 170R102 170R122 170R152 170R162 170R202 170R252 180R101 180R151 180R201 180R251 180R301 180R401 180R501 180R601 180R751 180R801 180R102 180R122 180R152 210R122 210R162 210R202 210R252 210R302 210R402 200R101 200R151 200R201 200R251 200R301 200R401 200R501 200R601 201R101 201R151 201R201 201R251 201R301 201R401 201R501 201R601 201R751 201R801 202R101 202R151 202R201 202R251 202R301 202R401 202R501 202R601 202R751 202R801 202R102 203R101 203R151 203R201 203R251 203R301 203R401 203R501 203R601 203R751 203R801 203R102 203R122 203R152 203R162 203R202 203R252 203R302 12-22 PA1 B-0.2 B-0.5 B-0.9 B-1.8 C10 C20 C50 C50 C50 C100 C100 C100 C200 C200 C200 C400 C400 C400 C400 C400 C400 C800 – – – – – – C10 C10 C10 C10 – – – – – – – – – – – – – – – – – C100 C100 C100 C200 C200 C200 C50 C50 C100 C100 C100 C200 C200 C200 C20 C50 C50 C100 C100 C100 C200 C200 C200 C200 C20 C20 C50 C50 C50 C100 C100 C100 C200 C200 C200 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 – – – 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 1.2 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 – – – 2.4 2.4 1.2 0.6 0.6 0.3 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 1.2 1.2 0.6 0.3 0.3 0.3 0.3 2.4 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 – – – 2.4 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – – – – 2.4 1.2 1.2 0.6 0.6 0.6 0.6 0.3 0.3 – – – – – 2.4 1.2 1.2 0.6 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 1.2 0.6 0.3 0.3 0.3 – 2.4 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 – – 2.4 1.2 1.2 0.6 0.8 0.3 0.3 0.3 0.3 C20 C20 C20 C20 C50 C50 C100 C100 C100 C100 C200 C200 C200 C200 C200 C200 C200 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – 2.4 2.4 1.2 1.2 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – 2.4 2.4 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.33 1.33 1.33 1.33 Relay Class 50:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 4000:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1200:5 1600:5 2000:5 2500:5 3000:5 4000:5 100:5 150:0 200:5 250:5 300:5 400:5 500:5 600:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 j Mounting brackets on page 12-24 © 2000 Square D All Rights Reserved B-0.1 Rating Factor 30°C Ambient 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Current Rating (Amperes) Discount Schedule ANSI Accuracy Classification – 60 Hz Metering Class Price $418. 458. 493. 515. 531. 549. 578. 597. 619. 648. 679. 699. 724. 737. 761. 791. 819. 859. 84. 84. 84. 84. 84. 84. 88. 88. 115. 115. 143. 143. 143. 143. 65. 65. 65. 65. 65. 65. 65. 65. 71. 71. 91. 91. 97. 324. 324. 324. 368. 368. 411. 427. 427. 427. 427. 427. 427. 427. 427. 349. 349. 349. 349. 349. 359. 359. 359. 370. 389. 304. 304. 304. 313. 313. 319. 319. 323. 323. 330. 365. 269. 269. 269. 269. 269. 269. 269. 269. 275. 275. 275. 275. 287. 287. 287. 287. 287. k Catalog Numbers shown in bold letters are normally stocked items. 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Instrument Transformers – 600 Volt Class Multi-Ratio, Rectangular, Split Core CTs Class 4210 Multi-Ratio Current Transformers Models 151R and 312R X5 X4 X3 X2 Torroidal Current Transformers UR/cUR Recognized 60 Hz-Model 312R, 25–400 Hz-Model 151R X1 Window Size Catalog Numberk (without brackets)j Currentc Rating (Amperes) Relay Class 41⁄2" 312R601 312R122 312R202 312R302 312R402 600:5MR 1200:5MR 2000:5MR 3000:5MR 4000:5MR 67⁄8" 151R601 151R122 151R202 151R302 151R402 600:5MR 1200:5MR 2000:5MR 3000:5MR 4000:5MR A CL B HI CL B C ANSI Accuracy Classification – 60 Hz Metering Class B-0.1 B-0.2 B-0.5 B-0.9 B-1.8 Rating Factor 30°C Ambient C100 C200 C400 C400 C400 – – – – – – – – – – – – – – – – – – – – – – – – – 1.5 1.5 1.5 1.5 1.33 $ 466. 533. 608. 653. 693. C200 C400 C400 C400 C800 – – – – – – – – – – – – – – – – – – – – – – – – – 1.33 1.33 1.33 1.33 1.33 772. 901. 972. 1012. 1041. Price c See chart at left for multi-ratio (MR) taps. Rectangular Window Current Transformers UR/cUR Recognized 50–400 Hz Dimensions (inches) A B C 151R 6.88 12.25 4.12 312R 4.50 11.00 2.38 Window Size Catalog Numberk (without brackets)j Current Rating (Amperes) B-0.1 B-0.2 B-0.5 B-0.9 21⁄8" X 41⁄4" 260R101 260R151 260R201 260R301 260R401 260R601 260R801 260R122 260R162 260R202 260R252 260R302 260R402 100:5 150:5 200:5 300:5 400:5 600:5 800:5 1200:5 1600:5 2000:5 2500:5 3000:5 4000:5 1.2 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 – – – – – – – – – – – – – 33⁄4" X 77⁄16" 560R401 560R501 560R601 560R751 560R801 560R102 560R122 560R152 560R162 560R202 560R252 560R302 560R322 560R402 560R502 400:5 500:5 600:5 750:5 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 3200:5 4000:5 5000:5 1.2 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.4 2.4 1.2 1.2 1.2 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Multi-Ratio Taps (Models 151, 312, 781, 786) Nominal Ratio Current Ratioq (Amperes) 600:5 600/500/450/400/300/250/200/150/100/50:5 1200:5 1200/1000/900/800/600/500/400/300/200/100:5 2000:5 2000/1600/1500/1200/1100/800/500/400/300:5 3000:5 3000/2500/2200/2000/1500/1200/1000/800/500/300:5 4000:5 4000/3500/3000/2500/2000/1500/1000/500 q Taps in accordance with ANSI C57.13 and NEMA SG-4. B E A 260R Price B-1.8 Rating Factor 30˚ C Ambient – – – – – – – – – – – – – – – – – – – – – – – – – – 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 1.0 1.0 $178. 178. 178. 178. 178. 178. 204. 235. 235. 256. 256. 256. 298. – – 2.4 1.2 1.2 1.2 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 – – 2.4 2.4 2.4 1.2 1.2 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 143. 143. 143. 143. 143. 145. 145. 145. 145. 150. 150. 150. 160. 160. 175. Split-Core Current Transformers Model 270R is UR/cUR Recognized 60 Hz C D Window Size Catalog Numberk (without brackets)j Current Rating (Amperes) B-0.1 B-0.2 B-0.5 B-0.9 39⁄16" x 83⁄16" 270R401 270R501 270R601 400:5 500:5 600:5 – – – – – – – – – 39⁄16" x 83⁄16" 270R801 270R102 270R122 270R152 270R162 270R202 270R252 270R302 270R402 270R502 800:5 1000:5 1200:5 1500:5 1600:5 2000:5 2500:5 3000:5 4000:5 5000:5 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 2.4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 31⁄2" x 61⁄4" 273201 273251 273301 273401 273501 273601 273801 273102 273122 273162 273202 273252 273302 273402 200:5 250:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1600:5 2000:5 2500:5 3000:5 4000:5 ... ... 2.4 2.4 2.4 2.4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 ... ... ... ... ... 2.4 2.4 1.2 1.2 1.2 1.2 1.2 1.2 1.2 Dimensions (inches) Model ANSI Accuracy Classification – 60 Hz Metering Class A B C D E 2.13 4.25 2.12 4.88 7.25 270R 3.56 8.81 3.00 9.25 13.06 273 3.50 6.25 3.27 9.25 11.28 560R 3.75 7.45 1.13 5.53 11.13 ANSI Accuracy Classification — 60 Hz Metering Class Price B-1.8 Rating Factor 30°C Ambient – – – – – – 1.33 1.33 1.33 $447. 447. 447. – 2.4 2.4 2.4 2.4 1.2 1.2 1.2 1.2 1.2 – – – – – 2.4 2.4 1.2 1.2 1.2 – – – – – – – 2.4 1.2 1.2 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.0 1.0 1.0 387. 427. 427. 427. 427. 457. 457. 479. 502. 564. ... ... ... ... ... ... ... 2.4 2.4 2.4 1.2 1.2 1.2 1.2 ... ... ... ... ... ... ... ... ... ... 2.4 2.4 1.2 1.2 ... ... ... ... ... ... ... ... ... ... ... ... 2.4 1.2 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.00 1.00 369. 369. 369. 369. 369. 447. 369. 396. 396. 396. 422. 422. 443. 475. 3/00 PA1 Discount Schedule 12 j Mounting brackets on page 12-24. k Catalog Numbers shown in bold type are normally stocked items. TRANSFORMERS Model © 2000 Square D All Rights Reserved 12-23 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Instrument Transformers – 600 Volt Class Bushing Current Transformers, Auxiliary Current Transformers, Mounting Brackets–Class 4210 Bushing Current Transformers 50–400 Hz Models 780R, 781R, 785R, 786R 9.88 T 251 6.5 H2 Window Size 9.88 H1 251 61⁄2" Model T (inches) 780R 781R 785R 786R 3.38 3.38 6.75 6.75 Model 81X 10-32 Studs 61⁄2" .75 19 6.38 162 61⁄2" 5.88 3.25 149 83 Mounting Brackets Bracket Price 2NR MB-1 $ 3.90 5NR MB-1 3.90 7RL MB-7 5.00 54R Included ... 64R MB-10 3.70 66R MB-12 5.30 74R MB-16 5.30 76R MB-18 5.30 81X MB-81 11.70 100R MB-31 11.70 110R MB-32 11.70 120R MB-31 11.70 140R MB-32 11.70 151R MB-32 11.70 152R MB-32 11.70 170R MB-30 11.70 180R MB-9 7.10 200R Included ... 201R Included ... 202R Included ... 203R Included 210R MB-32 260R Not Available ... 270R Not Available ... 273 Not Available ... 61⁄2" Current c Rating (Amperes) Relay Class ANSI Accuracy Classification – 60 Hz Metering Class B-0.1 B-0.2 B-0.5 B-0.9 B-1.8 Rating Factor 30°C Ambient Price 780R500 780R750 780R101 780R151 780R201 50:5 75:5 100:5 150:5 200:5 – C10 C10 C20 C20 – 1.2 2.4 0.6 0.6 – 2.4 2.4 1.2 1.2 – – – – 2.4 – – – – – – – – – – 2.0 2.0 2.0 2.0 2.0 $207. 207. 207. 207. 207. 780R251 780R301 780R401 780R501 780R601 250:5 300:5 400:5 500:5 600:5 C20 C50 C50 C50 C100 0.6 0.3 0.3 0.3 0.3 0.6 0.6 0.3 0.3 0.3 1.2 1.2 0.6 0.6 0.3 2.4 1.2 1.2 0.6 0.6 – 2.4 1.2 1.2 0.6 2.0 2.0 2.0 2.0 2.0 207. 207. 207. 207. 207. 780R751 780R801 780R102 780R122 780R152 750:5 800:5 1000:5 1200:5 1500:5 C100 C100 C100 C200 C200 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.6 0.3 0.3 0.3 2.0 2.0 2.0 2.0 2.0 223. 223. 223. 223. 223. 780R162 780R202 780R252 780R302 780R402 1600:5 2000:5 2500:5 3000:5 4000:5 C200 C200 C200 C200 C200 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 2.0 2.0 2.0 1.5 233. 233. 233. 233. 248. 781R601 781R122 781R202 781R302 781R402 600:5 MR 1200:5 MR 2000:5 MR 3000:5 MR 4000:5 MR C100 C200 C200 C200 C200 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 2.0 2.0 2.0 2.0 1.5 278. 293. 304. 304. 320. 785R500 785R750 785R101 785R151 785R201 50:5 75:5 100:5 150:5 200:5 C10 C20 C20 C50 C50 2.4 1.2 1.2 0.6 0.6 2.4 1.2 1.2 0.6 0.6 – – 2.4 1.2 1.2 – – – 2.4 2.4 – – – _ 2.4 2.0 2.0 2.0 2.0 2.0 377. 377. 377. 377. 377. 785R251 785R301 785R401 785R501 785R601 250:5 300:5 400:5 500:5 600:5 C50 C100 C100 C100 C200 0.3 0.3 0.3 0.3 0.3 0.6 0.3 0.3 0.3 0.3 1.2 0.6 0.3 0.3 0.3 1.2 0.6 0.6 0.6 0.3 2.4 1.2 1.2 0.6 0.6 2.0 2.0 2.0 2.0 2.0 377. 377. 377. 377. 377. 785R751 785R801 785R102 785R122 785R152 750:5 800:5 1000:5 1200:5 1500:5 C200 C200 C200 C400 C400 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 2.0 2.0 2.0 2.0 377. 405. 405. 405. 405. 785R162 785R202 785R252 785R302 785R402 1600:5 2000:5 2500:5 3000:5 4000:5 C400 C400 C400 C400 C400 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 2.0 2.0 2.0 1.5 405. 423. 423. 423. 451. 786R601 786R122 786R202 786R302 786R402 600:5 MR 1200:5 MR 2000:5 MR 3000:5 MR 4000:5 MR C200 C400 C400 C400 C400 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2.0 2.0 2.0 2.0 1.5 448. 476. 493. 493. 522. c See chart on Page 12-23 for multi-ratio (MR) taps. Auxiliary Current Transformer Catalog Number (without brackets) 81X05000100 81X05000200 81X05000250 81X05000500 81X07500500 81X10000500 81X12500500 81X15000500 Ratio Price 5:1 5:2 5:2.5 5:5 7.5:5 10:5 12.5:5 15:5 $425. 425. 425. 425. 425. 425. 425. 425. Model 81X Accuracy 0.3B0.1, B0.2, B0.5@60 Hz, RF=1.5@30°C ... 11.70 12 TRANSFORMERS Model Catalog Number 12-24 © 2000 Square D All Rights Reserved PA1 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type Over 600 Volts Class 7432 601 Volts thru 15,000 Volts – Three Phase – Indoor All transformers are built with 220°C insulation and 150°C temperature rise. For 115°C rise add 10% to price and F to catalog number. For 80°C rise add 20% to price and B to catalog number. Check with factory to verify dimensional changes and weights. For copper windings add 20% kV Class Code Primary Secondary 2.4 30 kV B.I.L 13 14 15 16 17 2400s 2400s 2400s 2400s 2400s 208Y/120 480Y/277 240s 480s 600s 5 30 kV B.I.L 18 19 20 21 22 23 25 26 27 28 29 30 31 4160s 4160s 4160s 4160s 4160s 4160Y/2400 4160Y/2400 4160/2400 4800s 4800s 4800s 4800s 4800s 208Y/120 480Y/277 240s 480s 600s 240s 480s 600s 208Y/120 480Y/277 240s 480s 600s 15 60 kV B.I.L 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 7200s 7200s 7200s 7200s 7200s 12000s 12000s 12000s 12000s 12000s 12470s 12470s 12470s 12470s 12470s 12470Y/7200 12470Y/7200 12470Y/7200 13200s 13200s 13200s 13200s 13200s 13200Y/7620 13200Y/7620 13200Y/7620 13800s 13800s 13800s 13800s 13800s 208Y/120 480Y/277 240s 480s 600s 208Y/120 480Y/277 240s 480s 600s 208Y/120 480Y/277 240s 480s 600s 240s 480s 600s 208Y/120 480Y/277 240s 480s 600s 240s 480s 600s 208Y/120 480Y/277 240s 480s 600s Standard high voltage taps: 4-2.5%, 2AN and 2BN. For 4-2.5% FCBN, add BN to catalog number. Catalog Number kVA Price PE6D Weight (Pounds) Mounting Enclosurec See Page 12-8 2.4 kV and 5 kV Voltage Class 60 Hz 150°C Rise 112.5 150 225 300 112T( 150T( 225T( 300T( )H )H )H )H $14201. 17446. 23474. 28324. 1400 1600 1900 2100 Floor Floor Floor Floor 28-D 28-D 29-D 29-D 500 750j 1000j 500T( )H 750T( )H 1000T( )H 33077. 41419. 51410. 3200 3900 7400 Floor Floor Floor 31-D 31-D 33-F 1500j 2000j 2500j 1500T( )H 2000T( )H 2500T( )H 61789. 70907. 85748. 9000 10900 12200 Floor Floor Floor 33-F 34-F 34-F )H )H )H )H )H $16274. 20011. 27257. 31816. 38800. 2000 2200 2800 3300 5000 Floor Floor Floor Floor Floor 30-D 30-D 31-D 31-D 32-F 750j 1000j 1500j 750T( )H 1000T( )H 1500T( )H 46075. 58588. 67027. 6000 7400 9000 Floor Floor Floor 33-F 33-F 33-F 2000j 2500j 3000j 2000T( )H 2500T( )H 3000T( )H 78570. 90986. 117176. 10900 12200 15400 Floor Floor Floor 34-F 34-F 35-F 15 kV Voltage Class 60 Hz 150°C Rise 112.5 150 225 300 500 112T( 150T( 225T( 300T( 500T( j Dimensions and prices listed for 480 volt secondary only. For 240 volt or 208 volt, contact your nearest Square D/Schneider Electric sales office. 601 Volts thru 15,000 Volts – Single Phase – Indoor All transformers are built with 220°C insulation and 150°C temp. rise. or 115°C rise add 10% to price and F to catalog number. For 80°C rise add 20% to price and B to catalog number, and check with factory for dimensional changes. Catalog Number Price PE6D Weight (Pounds) Mounting Enclosurec See Page 12-8 2.4 kV Voltage Class 60 Hz 150°C Rise 167 250 333 167S( )H 250S( )H 333S( )H $15148. 19751. 24261. 1500 2200 3000 Floor Floor Floor 167S( )H 250S( )H 333S( )H $16259. 21104. 25826. Code Primary Secondary 2.4 14 25 2400 2400 120/240 277 5 30 kV B.I.L 13 15 16 24 26 27 2400/4160Y 4800 4160 2400/4160Y 4800 4160 120/240 120/240 120/240 277 277 277 15 60 kV B.I.L 17 18 28 29 19 20 21 22 23 30 31 32 33 34 4160/7200Y 7200 4160/7200Y 7200 7200/12470Y 7620/13200Y 12470 13200 13800 7200/12470Y 7620/13200Y 12470 13200 13800 120/240 120/240 277 277 120/240 120/240 120/240 120/240 120/240 277 277 277 277 277 28-D 29-D 29-D 5 kV Voltage Class 60 Hz 150°C Rise 167 250 333 kV Class 1500 2200 3200 Floor Floor Floor 28-D 29-D 29-D 2400 3400 5000 Floor Floor Floor 31-D 31-D 31-D 15 kV Voltage Class 60 Hz 150°C Rise 167 250 333 167S( )H 250S( )H 333S( )H $18712. 24235. 28945. c Enclosures for indoor use only. Letters in parenthesis refer to enclosure styles on page 12-8. Transformers suitable for outdoor use available on special order. Consult your nearest Square D/Schneider Electric sales office. Lugs: Furnished by customer. f Dimensions – DO NOT use for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. Special Notes 1. Distribution class lightning arresters are recommended as good practice, but are not included in the above prices. Arrester addition may affect dimensions. Contact your nearest Square D/Schneider Electric sales office. 2. For 15 kV transformers requiring bottom entrance or exit, a separate compartment is required for adequate termination space and clearance. Transformers 1500 kVA and above with top entrance or exit may require a separate compartment to provide adequate wiring space. Contact your nearest Square D/Schneider Electric sales office, for special requirements. 3. If transformer requires a 94" high enclosure for switchgear line-up, or if special enclosure is required, contact your nearest Square D/Schneider Electric sales office. 4. For 95 kV BIL consult your nearest Square D/Schneider Electric sales office. (May affect dimensions). 3/00 PE6D Discount Schedule To Complete Catalog Number To complete the single phase or three phase catalog numbers on this page, select the voltage you require from the chart above. Insert the voltage code number in place of the ( ) in the catalog number. Ex.1000 kVA, 3 Ø, 60 Hz, 150˚C temp. rise, 60 kV BIL, NEMA sound level, ventilated enclosure, 13.2 kV delta 480Y/277 = 100051H with 22.5% full capacity taps. 2AN and 2BN. The correct catalog number for a 167 kVA, 2400/4160Y-120/240, 1 Ø 60 Hz unit is 167S13H. The unit would be supplied with 2-2.5% above and 2–2.5% full capacity below normal taps on the primary. © 2000 Square D All Rights Reserved 12 kVA TRANSFORMERS Standard high voltage taps: 4-2.5%, 2AN and 2BN. For 4-2.5% FCBN, add BN to catalog number. 12-25 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type Over 600 Volts–Three Phase Class 6010 Most switches are supplied as fusible disconnects. The fuse access door is mechanically interlocked with the switch operating mechanism, permitting entry to the fuses only when the switch is open. Key-interlock on the fuse access door or switch operating mechanism, allows interlocking with other devices. Distribution class lightning arresters, when required, are located below the fuses in the incoming line section. Line-side cable entry is at the top or bottom of the switch. For service voltages above 4.8 kV, an 18" pull box on the top of the switch is required to provide sufficient room for stress-cones when cable entry is at the top. Where switching and overcurrent protection are provided elsewhere, a full-height air-filled terminal chamber (22" wide) can be provided in place of the HVL switch as the incoming section. Primary Switch Ratings, Type HVL Type Switch Manual Non-Fused Model III POWER-ZONE Package Unit Substations General Model III Power-Zone Package Unit Substations incorporate into one pre-assembled, unitized module an HVL switch, Dry-Type transformer and Molded-Case circuit breaker distribution section. All components are manufactured by Square D and the complete package substation is engineered and tested as one integral unit by Square D, assuring the user of a fully coordinated design for maximum reliability. The Model III is only 36" deep and 85" high, so it will pass through most existing doorways. Ventilation is toward the front, at the top of the transformer section, so the unit can be installed against a wall or in a corner without alteration or derating. Model III Power-Zone package unit substations are ideal for renovations requiring increased electrical demand as well as for high rise applications and new construction requiring multiple zones and a small footprint. 75 kVA Through 500 kVA TRANSFORMERS Model III Power-Zone Package Unit Substations are available in sizes from 75 kVA through 500 kVA with three phase primary voltages of 2400 volts through 13,800 volts. When equipped with fan cooking, kVA ratings as high as 667 kVA are available, AA/FA. Secondary voltages for 600 V delta, 480 V delta, 480Y/277, 208Y/120 and 240 V delta are available. The transformer is built with 220°C insulation. 150°C, 115°C or 80°C Rise units are offered. Largest 80°C Rise size available is 300 kVA. The secondary circuit breaker distribution section may be equipped with an individually mounted secondary main breaker or an I-LINE® distribution panelboard. Branch circuit breakers as small as 15 A single pole FY or FA Frame (11⁄2 inches mounting height) to as large as 1200 A NA Frame 3-pole circuit breakers (15 inches mounting height) may be installed. ME/NE Frame Electronic Trip breakers and I-LIMITER® High interrupting capacity current limiting circuit breakers may also be used. Switch Ratings Continuous Interrupt Momentary Asym. 10 Cycle 600 A 600 A 61,000 A Fault Close Asym. 5 kV BIL 15 kV BIL 40,000 A 60 kV 95 kV Transformer Section Special Barrel-wound dry-type transformers employing Resinencapsulated VPIc techniques are used to achieve the low-loss, compact design necessary for the space-saving package substation concept. Sizes from 75 through 500 kVA are made. Class H, 220°C insulation is used throughout. Temperature rise is 150°C as standard, although 80°C or 115°C low-temperature premium transformers are available through 300 kVA. Aluminum windings are standard with copper as an option, (500 kVA, 115°C rise transformers are available with copper windings only.) Four full capacity 21⁄2% taps are provided— two above normal voltage and two below. Fan-cooling is optional. When selected, it increases the self-cooled rating of the transformer an additional 331⁄3%. The Model 98 digital temperature controller is used on all fan-cooled units. This system provides precision control through the use of three high accuracy thermocouple type temperature sensors–one in each phase. The controller has a membrane front panel for displaying the temperature for all three phases with individual readings. The hottest phase temperature is automatically displayed. The Model 98 features simple three button operation with fan, alarm and trip function controlled by hottest phase temperature. The Model 98 is POWERLOGIC compatible. Basic Insulation Levels kV Class Primary Voltages BIL 1.2 All 600 V and Below Secondary 10 kV 4 kV 2.5 2400 V 20 kV 10 kV 5.0 4160 V, 4800 V 30 kV 12 kV 7.2 6900 V, 7200 V 30 kV 12 kV 8.7 8320 V 45 kV 19 kV 12, 12.47, 13.2, 13.8 kV 60 kV 31 kV 15.0 600 Hz Test Volt c Vacuum-Pressure Impregnation 12 Incoming Line Section Most Model III Power-Zone Package Unit Substations are supplied with a Square D type HVL Load Interrupter switch. This switch uses a storedenergy spring mechanism to provide Quick-Make, Quick-Break operation. A direct acting, permanently attached handle gives positive indication of the switch position—up for closed, down for open— just as in Square D’s line of safety switches. A viewing window is provided for positive confirmation of blade position. 12-26 © 2000 Square D All Rights Reserved 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type Over 600 Volts–Three Phase Class 6010 POWER-ZONE® Model III Package Unit Substations Distribution Section I-LINE Branch Breaker Data I-LINE® Mounted Molded Case Circuit Breakers Type Molded Case Circuit Breakers are group mounted in an I-LINE panelboard section offering the inherent ease of installation for which the plug-on I-LINE circuit breaker has become known. All circuit breakers are quick-make, quick-break, thermal-magnetic, permanent trip type and are factory calibrated and sealed for accurate overcurrent response and maximum short-circuit strength. ME and NE breakers are available with solid-state logic trip elements. Current-limiting high interrupting capacity. FI, KI and LI breakers are also available. Breakers may be safely back-fed for use as main breakers. All circuit breakers are UL listed and carry integrated equipment rating when used exclusively with other Square D breakers in intended assembly. Instead of a panelboard, molded case circuit breakers can be individually mounted as a Main Breaker for separately installed equipment. All circuit breakers are quick-make, quick-break, thermalmagnetic, permanent trip molded case circuit breakers and are factory calibrated and sealed for accurate overcurrent response and maximum short-circuit strength. L/R Interrupting Rating, Kilo Amperes (RMS Symmetrical) R 1P 2P 3P 120 240 277 480 600 100 3 3 3 3 3 41⁄2 41⁄2 41⁄2 41⁄2 41⁄2 41⁄2 41⁄2 k k k k k kf 18 10 18 ... 65 ... ... 10 18 18 65 200 14 ... 14 ... 25 ... ... ... 14 14 25 200 ... ... ... 14 18 100 225 ... ... ... ... ... ... 3 3 41⁄2 41⁄2 41⁄2 9 41⁄2 41⁄2 41⁄2 41⁄2 41⁄2 9 k k kf kf kf k ... ... ... ... ... ... 10 22 25 65 200 65 ... ... ... ... ... ... ... ... 25 35 200 65 ... ... 22 25 100 25 Q4 LA LH LIa MEq 400 ... ... ... ... ... 6 6 6 12 9 6 6 6 12 9 k k k k k ... ... ... ... ... 22 42 65 200 65 ... ... ... ... ... ... 30 35 200 65 ... 22 25 ... 25 MA MH MEq 800 ... ... ... 9 9 9 9 9 9 k k k ... ... ... 42 65 65 ... ... ... 30 65 65 22 25 25 NA NC NEq 1200 ... ... ... 15 15 15 15 15 15 k k k ... ... ... 100 125 125 ... ... ... 50 100 100 25 65 65 Q2 Q2-H KA KH KIa MEq Breakers shown in table on right as mounting “L/R” may be mounted on either left-hand or right-hand side of panelboard section. Those shown as “R” mount on right-hand side only. Mounting Ht. (IN) 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 ... FY FA 240 V FA 480 V FA 600 V FH FIa I-LINE panels are available in 800 A and 2000 A main bus ratings. Maximum mounting space is 401⁄2" each side (total of 81"). Individually Mounted Main Breakers Frame Size (Amps) a Current limiting I-LIMITER circuit breakers. f R only on 2000 A main bus I-LINE. q Electronic trip. Main Circuit Breaker Data Frame Size (Amps) Type 225 400 800 1000 1000 1200 1200 1200 MEL MEL MEL MAL MHL NAL NCL NEL Circuit breakers that may be individually mounted as main disconnecting devices include the ME and NE frame solid-state electronic trip circuit breakers as well as MA, MH, NA and NC frame units as detailed on right. Interrupting Rating RMS Kilo Amperes Symmetrical 240 V 480 V 600 V Ampere Rating (Amps) 65 65 65 42 65 100 125 125 65 65 65 30 50 50 100 100 25 25 25 25 25 25 65 65 100-225 250-400 450-800 125-1000 125-1000 600-1200 600-1200 600-1200 Available Secondary Metering POWER METER or POWER LOGIC METER, potential transformers, current transformers. Dimensions and Weights 2.00 51 2.00 Model 98 Compartment Meter Compartment 51 5.75 Removable Cover 34.00 864 1-inch Minimum Rear Clearance Recommended. For Rear Transformer Removal, 30-inch Aisle Required. Grill under Removable Cover 146 12.00 305 36.00 914 51 L.V. 2.00 51 85.38 6.00 6.00 152 152 2169 3.00 76 10.00 2.00 254 51 5.00 H.V. 38.00 48.00 965 1219 86.00 Lifting Jacks 6.00 152 127 4.00 L.V. 102 36.00 914 2184 Split for Shipment 32.00 Front View 813 kVA Weight (Aluminum Windings) 75 1121⁄2 150 225 300 500 3200 3350 3600 4400 4700 5000 8.00 203 12 2023 TRANSFORMERS Top Conduit Entrance 79.63 Viewing Window NOTE: High voltage is shown on the left. High voltage on the right is also available. 2.00 H.V. Bottom Conduit Entrance Contact your nearest Square D/Schneider Electric sales office for pricing assistance. I-LIMITER, I-LINE and POWER-ZONE are Registered Trademarks of Square D Company or related companies. 3/00 © 2000 Square D All Rights Reserved 12-27 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com