Coaxial Low Pass Filter 50Ω BLP-1.9+ DC to 1.9 MHz Maximum Ratings Operating Temperature -55°C to 100°C Storage Temperature -55°C to 100°C RF Power Input 0.5W max. Permanent damage may occur if any of these limits are exceeded. Features • rugged shielded case • other standard and custom BLP models available with wide selection of fco CASE STYLE: FF55 ConnectorsModel BNCBLP1.9+ Applications +RoHS Compliant • test equipment • lab use • video equipment The +Suffix identifies RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications Low Pass Filter Electrical Specifications­ Outline Drawing PASSBAND (MHz) fco (MHz) Nom. STOPBAND (MHz) VSWR (:1) (loss < 1 dB) (loss 3 dB) (loss > 20 dB) (loss > 40 dB) Passband Typ. Stopband Typ. DC-1.9 2.5 3.4-4.7 4.7-200 1.7 18 1 dB compression at +13 dBm input power typical frequency response electrical schematic AT T E NUAT ION, dB 40 dB 3 dB 1 dB 0.9 Outline Dimensions ( inch mm ) 60 40 20 0 1.75 3 Return Loss (dB) Insertion Loss (dB) _ σ x 0.090.01 0.240.02 0.260.01 0.310.01 0.400.02 0.450.02 0.750.12 2.930.75 8.321.21 14.691.17 17.711.12 23.301.01 25.890.96 30.680.90 32.920.87 37.120.84 41.000.81 44.610.79 49.670.81 52.780.80 55.740.88 60.000.86 92.504.17 91.193.63 92.392.10 87.802.75 89.053.87 87.172.60 92.877.14 86.824.04 40.00 22.11 23.88 26.19 21.19 21.37 15.39 5.05 1.43 0.59 0.45 0.32 0.29 0.24 0.22 0.20 0.18 0.17 0.15 0.14 0.13 0.11 0.17 0.42 0.45 0.46 0.47 0.46 0.44 0.44 1 10 100 FREQUENCY(MHz) 1000 1000 40 30 20 10 0.1 1.00 1.00 1.10 1.10 1.20 1.30 1.30 1.40 1.40 1.50 1.60 1.60 1.70 1.80 1.90 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.70 2.80 3.00 3.10 3.30 3.40 3.60 3.80 RETURN LOSS at RF level of 0 dBm at RF level of 0 dBm Group Delay (nsec) 390.94 393.92 397.21 400.27 406.34 410.76 417.77 425.39 434.33 444.37 455.27 468.79 484.50 506.65 554.15 579.78 642.41 720.76 779.41 768.87 675.19 579.64 390.84 286.22 230.56 182.81 153.96 132.22 109.19 92.80 GROUP DELAY 800 600 400 200 0 0 0.1 Frequency (MHz) GROUP DELAY (nsec) RETURN LOSS (dB) INSERTION LOSS (dB) 50 80 1.35 Typical Performance Data Frequency (MHz) INSERTION LOSS at RF level of 0 dBm 1 F R E QUE NC Y / F co 0.10 1.20 1.40 1.60 1.80 1.90 2.10 2.30 2.50 2.70 2.80 3.00 3.10 3.30 3.40 3.60 3.80 4.00 4.30 4.50 4.70 5.00 29.40 53.80 78.10 102.50 126.90 151.30 175.60 200.00 100 R F OUT 20 dB DC B D wt .54 2.59 grams 13.72 65.79 40.0 R F IN 1 10 100 1000 FREQUENCY(MHz) 1.0 1.7 2.4 3.1 FREQUENCY (MHz) 3.8 Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com REV. C M151107 BLP-1.9+ 150609