Solar Fuse Products Fuse Holder & Block Selection Guide Scan this tag to get the latest product information for Solar Products. Page 54-55 Solar Products Volt Fuses Size 600Vdc . . . . . . . . . PVM . . . . . 13⁄32˝ x 1 1⁄2˝ . . . . . . . . . . . 56 600Vac /300Vdc . . .PVCF . . . . .CUBEFuse . . . . . . . . .57-58 600Vac/dc . . . . . . . PVS-R . . . . RK5 . . . . . . . . . . . . . . . . 59 1000Vdc . . . . . . . . PV . . . . . . .10x38mm . . . . . . . . . . . 60 1000/1100Vdc . . . . PV . . . . . . .14x51mm . . . . . . . . . . .61 1000Vdc . . . . . . . . NH1 . . . . . .NH Size 1 . . . . . . . . . . . 62 1000Vdc . . . . . . . . XL PV . . . . XL Size 01, 1, 2, 3 . . .63-65 1300/1500Vdc . . . . PV . . . . . . .14x65mm . . . . . . . . . . . 66 1200/1500Vdc . . . . XL PV . . . . XL Size 01, 1, 2, 3 . . .67-69 RED indicates NEW information 53 Solar Fuse Products Holders & Blocks For Branch Circuit Rated Fuses 600 Volts Fuses Volts Midget CF RK5 PVM CFPV PVS-R 600V 600V 600V Page 56 57 59 Holders • TCFH Series CUBEFuse holder • CHM Series DIN-Rail mount holders • HEB Series in-line holders 32 274 310 Blocks CHM Series HEB Series TCFH Series BM Series Modular Knifeblade R600 Series CHPV Series CH14 Series HEB Series SD1XL-S Series SD2XL-S Series • Modular Knifeblade Fuse Blocks 250/600V, panel mount . . 289 • R600 Series RK5 open fuse blocks 296 • BM Series midget open fuse blocks 305 1000 Volts Fuses Volts 10x38mm 14x51mm NH1 01XL 1XL 2XL 3L PV-_A10 PV-_A14 PV-_ANH PV-_A-01XL PV-_A-1XL PV-_A-2XL PV-_A-3L 1000V 1000/1100V 1000V 1000V 1000V 1000V 1000V Page 60 61 62 63 63 63 63 Holders • • • • CHPV Series 10x38 DIN-Rail mount holders CH14 Series 14x51 DIN-Rail mount holders HEB Series* 10x38 in-line holders SD1 Series** NH1 holders 274-277 274-277 310 63 * Self certified to 1000Vdc. ** IEC only to 1000Vdc. Blocks • SD1XL-S Series 01XL & 1XL blocks • SD2XL-S Series 2XL blocks • SD3L-S Series 3L blocks 63 63 63 SD1-D-PV Series SD3L-S Series 54 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Solar Fuse Products Holders & Blocks For Branch Circuit Rated Fuses 1500 Volts Fuses Volts 01XL 1XL 2XL 3L 14x65mm PV-_A-01XL-15 PV-_A-1XL-15 PV-_A-2XL-15 PV-_A-3L-15 PV-_A14* 1500V 1500V 1500V 1500V 1300/1500V Page 63 63 63 63 66 Blocks 63 63 63 SD1XL-S Series SD2XL-S Series SD3L-S Series * Available with tags for bolt mounting or 10mm fixings for mounting in modular blocks for 10mm diameter fuses. ** IEC only to 1500Vdc. For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 55 Solar Products • SD1XL-S Series** 01XL & 1XL blocks • SD2XL-S Series** 2XL blocks • SD3L-S Series** 3L blocks Solar Fuse Products ⁄32˝ x 1 1⁄2˝ Midget PV Fuses Features and Benefits • Specifically designed to protect solar power systems in extreme ambient temperature per UL 2579 listed • Capable of withstanding high cycling and low level fault current conditions 30 A 15 A 20 A 100 AMP RATING 10 TIME IN SECONDS Specifications Description: A range of UL 2579 fast-acting 600Vdc Midget fuses specifically designed to protect solor power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault). Dimensions: 13⁄32˝ x 1 1⁄2˝ (10.3 x 38.1mm). Ratings: Volts — 600Vdc to UL 2579 Amps — 4-30A IR — 50kA DC (4-30A) Agency Information: UL Listed 2579, Guide JFGA, File E335324, CSA Component Certified C22.2. 5A PVM 8A 10 A 13 1 .1 Catalog Number PVM-10 PVM-15 PVM-30 Amp Rating 10 15 30 CURRENT IN AMPS Power Loss (Watts) 0.8 x In 1.0 x In 1.04 1.86 1.00 1.72 1.65 2.91 1,000 100 Power Loss (Watts) 10 .01 1 Typical Applications • Solar Combiner Boxes • Solar String Protectors In = Rated current Catalog Numbers (Amps) PVM-4 PVM-7 PVM-10 PVM-20 PVM-5 PVM-8 PVM-12 PVM-25 PVM-6 PVM-9 PVM-15 PVM-30 Dimensions - (mm) 1.5" ±0.031 (38.1mm) 0.407" ±0.005 (10.3mm) Recommended Fuse Holders & Blocks For the PVM Fuse • See page 54 Data Sheet: 2153 56 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 56 Solar Fuse Products Fast-Acting CUBEFuse™ PVCF Class CF Fuse • Maximize uptime and reliability using fuses designed and listed to UL 2579: Low Voltage Fuses - Fuses for Photovoltaic Systems. • Minimize chances of equipment failure and personnel injury when using full range fuses having the industry’s fastest response time to low-magnitude faults. • Maximize return on investment with fuses proven to withstand harsh temperatures. • Minimize design time, operating outage time and replacement cost with fuses qualified in excessively changing enviromental conditions. • Simplify compatibility with readily available industry standard Class CF holders. • Temperature Derating: Designed to maximize rated capacity in elevated environmental temperatures. • Overload Protection: Proven to clear faults faster than the UL requirement. • Power Loss: Minimal energy consumption leading to increased efficiency. Fuse Catalog Numbers Non-Indicating (Amps) PVCF35RN PVCF50RN PVCF80RN PVCF40RN PVCF60RN PVCF90RN PVCF45RN PVCF70RN PVCF100RN Agency Information: • UL 2579 Listed Fuse: Guide JFGA, File E335324 • CSA Certified Fuse: Class C22.2 Other Ratings/Specifications: Watts Loss at Rated Current: PVCF35RN: 5.45W PVCF60RN: 7.27W PVCF100RN: 11.50W Operating and Storage Temperature Range: -40 to 90°C Material Specifications: • Case: Glass filled PES (Polyethersulfone) • Terminals: Copper alloy • Terminal plating: Electroless tin Scan this tag to get the latest product information for the New PVCF CUBEFuse. Carton Quantity and Weight Amp Carton Weight Per Carton Rating Qty. lbs kg PVCF-35-60A 12 1.42 0.65 PVCF-70-100A 6 1.74 0.79 Recommended Fuse Holders For Class CF Fuses • See pages 32 and 33 Data Sheet: 2155 57 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 57 Solar Products Catalog Symbol: PVCF_RN Fast-Acting Fuse: 6 minutes maximum clearing time at 200% rated current for 30 to 60A fuse 8 minutes maximum clearing time at 200% rated current for 70 to 100A fuse Ratings: Volts — 600Vac (Photovoltaic applications) — 300Vdc Amps — 35-100A IR — 300kA RMS Sym. (UL) — 200kA RMS Sym. (CSA) — 50kA DC (UL & CSA) Features and Product Benefits Solar Fuse Products Fast-Acting CUBEFuse™ PVCF_RN Dimensions – in (mm) Fuse Amps A 2.13 35-40 (54.10) 2.13 45-50 (54.10) 2.13 60 (54.10) 3.01 70 (76.45) 3.01 80-90 (76.45) 3.01 100 (76.45) G 0.38 (9.65) 0.38 (9.65) 0.38 (9.65) 0.38 (9.65) 0.38 (9.65) 0.38 (9.65) B 100,000 INSTANTANEOUS PEAK LET THRU CURRENT IN AMPS 1000 F 0.63 (15.93) 0.63 (15.93) 0.63 (15.93) 0.58 (14.78) 0.58 (14.78) 0.58 (14.78) Current Limitation Curves 100A 35A 40A 50A 60A Time-Current Characteristic Curves–Average Melt Dimensions - in (mm) C D E 1.13 0.36 0.04 (28.58) (9.10) (1.02) 1.13 0.44 0.04 (28.58) (11.13) (1.02) 1.13 0.44 0.04 (28.58) (11.13) (1.02) 1.26 0.49 0.06 (32.00) (12.45) (1.60) 1.26 0.49 0.06 (32.00) (12.45) (1.60) 1.26 0.57 0.06 (32.00) (14.48) (1.60) B 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) 1.00 (25.40) 100 100A 60A 50A 40A 35A 10,000 1,000 300,000 100,000 PROSPECTIVE SHORT CIRCUIT CURRENT SYMMETRICAL RMS AMPS 10,000 1,000 100 10 100 TIME IN SECONDS A CUBEFuse Holders 1 Catalog Numbers (amps) Non-Indicating PVCF35RN PVCF40RN PVCF45RN PVCF50RN PVCF60RN PVCF70RN PVCF80RN PVCF90RN PVCF100RN 10,000 CURRENT IN AMPS 1,000 100 10 0.01 1 0.1 Fits Fuse Holder TCFH60N TCFH100N X X X X X X X X X X X X X X Data Sheet: 2155 58 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 58 Solar Fuse Products Limitron™ Fast-acting Fuses Time-Current Characteristic Curves—Average Melt • • • • 100A 200A 400A 10 1 100,000 Current in Amps 10,000 0.01 1,000 0.1 100 Typical Applications Photovoltaic systems Inverters Solar DC Safety Switches Recombiner Boxes 60A 100 10 Features and Benefits • Current limitation for non-inductive circuits provides Class RK5 current-limiting response to ground fault and short-circuit conditions. • Designed for the protection and isolation of photovoltaic systems. 30A 1000 Solar Products Specifications Description: A range of UL 2579 fast-acting 600Vdc Class RK5 fuses specifically designed to protect solar power systems in extreme ambient temperature, high cycling and low level fault current conditions (reverse current, multi-array fault). Dimensions: See page 15 for Class RK5 dimensions. Ratings: Volts — 600Vac to UL 248-12 ed Design new 600Vdc to UL 2579 e th t e e se to m Amps — 20-400A aic Fu lt o v L Photo dard U IR — 200kA RMS Sym. AC Stan 20kA DC (20-60A) 10kA DC (70-400A) Agency Information: UL Std. 248-12, Class RK5, UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579, CSA Component Certified C22.2. Time in Seconds PVS-R (600Vac/dc) Class RK5 Catalog Numbers (Amps) PVS-R-20 PVS-R-25 PVS-R-70 PVS-R-80 PVS-R-175 PVS-R-200 PVS-R-30 PVS-R-35 PVS-R-40 PVS-R-50 PVS-R-60 PVS-R-90 PVS-R-100 PVS-R-110 PVS-R-125 PVS-R-150 PVS-R-225 PVS-R-250 PVS-R-300 PVS-R-350 PVS-R-400 Recommended Fuse Holders & Blocks For Class RK5 Fuses • See page 19 Data Sheet: 4203 59 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 59 Solar Fuse Products 10x38mm Photovoltaic Fuses Dimensions - mm PV Specifications Class: gPV Description: A range of fuses specifically designed for the protection and isolation of photovoltaic strings. Dimensions: 13⁄32” x 11⁄2” (10.3 x 38.1mm). Ratings: Volts — 1000Vdc Amps — 1-20A IR — 33kAdc IR (Min) — 1.3 x In Agency Information: CCC pending, UL Listed E335324, IEC 60269-6, UL 2579, CSA. Features and Benefits • Capable of interrupting low over currents associated with faulted PV strings. • High DC voltage rating. • Variety of mounting options for flexibility. Catalog Numbers (Amps) Energy Integrals I2t (A2s) Current Rating (Amps) Pre-Arcing Total at 1000V 0.8 In In PV-1A10F 1 0.15 0.4 0.8 1.5 PV-2A10F 2 1.2 3.4 0.6 1.0 PV-3A10F 3 4 11 0.8 1.3 3.5 6.6 18 0.9 1.4 PV-4A10F 4 9.5 26 1.0 1.5 PV-5A10F 5 19 50 1.0 1.6 PV-6A10F 6 30 90 1.1 1.8 PV-8A10F 8 3 32 1.2 2.1 PV-10A10F 10 7 70 1.2 2.3 PV-12A10F 12 12 120 1.5 2.7 PV-15A10F 15 22 220 1.7 2.9 PV-20A10F 20 34 350 2.1 3.6 Part Number PV-3-5A10F Watts Loss Time-Current Characteristic Curves—Average Melt Recommended Fuse Holders & Blocks For Class RK5 Fuses • See page 19 Data Sheet: 720110 60 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Solar Fuse Products 14x51mm Photovoltaic Fuses 14x51mm Dimensions - mm Solar Products Specifications Description: A range of 14x51mm package fuse links specifically designed for protecting and isolating photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Dimensions: See dimension illustration. Construction: Melamine tube with silver fuse element. Ratings: Rated Volts — 1000Vdc (25 & 32A) 1100Vdc (15 & 20A) Rated Breaking Capacity: 10kA Amps — 15-32A Agency Information: UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending. Time-Current Characteristic Curves—Average Melt Features and Benefits • Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems • High DC voltage rating • Demonstrated performance in extreme temperature cycling conditions Typical Applications • Photovoltaic systems Catalog Numbers Current Energy Integrats I2t (A2s) Watts Loss Rated Total at Rated Rating Voltage Pre-Arcing 0.8In In (Amps) Voltage PV-15A14F 15 14 265 2.1 4 1100Vdc PV-20A14F 20 27 568 2.7 5 PV-25A14F 25 65 943 2.7 5.1 1000Vdc PV-32A14F 32 120 1740 3.3 6.2 Part Number Available Current (Amps), DC-Time Constant 1-3ms Recommended Fuse Holders & Blocks For Class RK5 Fuses • See page 19 Data Sheet: 720132 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 61 Solar Fuse Products NH1 Photovoltaic Fuses Specifications Description: A range of NH fuse links specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Dimensions: See dimension illustration. Construction: Melamine tube with silver fuse element. Ratings: Rated Volts — 1000Vdc Rated Breaking Capacity: 50kA Amps — 32-160A Agency Information: UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending. Features and Benefits • Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems • High DC voltage rating • Variety of mounting options for flexibility • Demonstrated performance in extreme temperature cycling conditions Dimensions - mm Size 1 Time-Current Characteristic Curves—Average Melt Typical Applications • Photovoltaic systems • Inverters Catalog Numbers Part Number PV-32ANH1 PV-40ANH1 PV-50ANH1 PV-63ANH1 PV-80ANH1 PV-100ANH1 PV-125ANH1 PV-160ANH1 Current Rating (Amps) 32 40 50 63 80 100 125 160 Energy Integrats I2t (A2s) Total at Pre-Arcing 1000V 80 720 185 1670 400 3600 470 4300 640 5760 1300 11,700 2600 23,400 5200 46,800 Watts Loss 0.8In In 4.3 4.6 5.4 6.1 7.9 8.4 8.9 12.2 8.5 9 10.5 12 15.5 16.5 17.5 24 Recommended NH1 Fuse Holders - SD(size)-D Available Current (Amps), DC-Time Constant 1-3ms • See page 54 Data Sheet: 720133 62 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Solar Fuse Products XL Photovoltaic Fuses 1000Vdc XL Style Photovoltaic Fuses Features and Benefits • Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems • High DC voltage rating • Variety of mounting options for flexbility • Demonstrated performance in extreme temperature cycling conditions Solar Products Typical Applications • Photovoltaic systems • Inverters Recomended Fuse Holders • SD1XL-S (suitable for 01 and 1XL) • SD2XL-S (suitable for 2XL) • SD3L-S (suitable for 3L) Specifications Description: A range of XL package fuses specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Dimensions: See dimension illustration. Ratings: Volts — 1000Vdc Amps — 63 to 630A: IR — 50kA @ 63 to 160A — 33kA @ 200 to 315A — 50kA @ 350 to 630A Agency Information: — IEC 60269-6 — RoHS compliant — UL 2579 — CSA — CCC (pending Part Number/Style Bladed Bolted PV-63A-01XL PV-63A-01XL-B PV-80A-01XL PV-80A-01XL-B PV-100A-01XL PV-100A-01XL-B PV-125A-01XL PV-125A-01XL-B PV-160A-01XL PV-160A-01XL-B PV-200A-1XL PV-200A-1XL-B PV-200A-2XL PV-200A-2XL-B PV-250A-2XL PV-250A-2XL-B PV-315A-2XL PV-315A-2XL-B PV-350A-3L PV-350A-3L-B PV-400A-3L PV-400A-3L-B PV-500A-3L PV-500A-3L-B PV-630A-3L PV-630A-3L-B Body Size 01 1 2 3 Current Rating (Amps) 63 80 100 125 160 200 200 250 315 350 400 500 630 See Data Sheet 720146 for information on the SD__-S Fuse Holders. Volts 1000Vdc 1000Vdc 1000Vdc 1000Vdc Energy Integrals I2t (A2s) Pre-Arcing Total @ 1000V 350 2520 660 4752 1350 9720 1930 13,896 3900 28,080 9400 27,260 4152 31,000 7721 57,000 17,600 130,000 30,885 160,700 44,000 230,000 48,300 251,200 100,000 520,000 Watts Loss 0.8In In 12 24 14 27 15 30 20 40 25 44 31 60 29 62 35 70 40 75 41 90 63 100 71 138 92 180 Data Sheet: 720134 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 63 Solar Fuse Products XL Photovoltaic Fuses for Solar Applications Dimensions - mm (not to scale) 01XL Blade Size 01XL Bolt Size 1XL Blade Size 1XL Bolt Size 2XL Blade Size 2XL Bolt Size 3L Blade Size 3L Bolt Size Data Sheet: 720134 64 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Solar Fuse Products XL Photovoltaic Fuses for Solar Applications Time Current Curves for 01XL and 1XL Time Current Curves for 2XL Solar Products Available Current (Amps), DC-Time Constant 1-3ms Available Current (Amps), DC-Time Constant 1-3ms Time Current Curves for 3L Available Current (Amps), DC-Time Constant 1-3ms Data Sheet: 720134 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 65 Solar Fuse Products 14x65mm Photovoltaic Fuses Features and Benefits • Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems • High DC voltage rating • Demonstrated performance in extreme temperature cycling conditions Dimensions - mm Cylindrical PV - (amp rating) A14LF Cylindrical with Tags PV - (amp rating) A14L-T 90.07 88.07 77.12 75.12 15.22 15.02 10.99 4.70 69.34 67.34 Cylindrical with 10mm Fixings PV - (amp rating) A14LF10F 86.77 84.77 14.22 14.02 10.25 10.05 Specifications Description: A range of 14x65mm package fuse links specifically designed for protecting and isolating photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Dimensions: See dimension illustration. Construction: Melamine tube with silver fuse element. Ratings: Rated Volts — 1300Vdc (25 & 32A) 1500Vdc (15 & 20A) Rated Breaking Capacity: 10kA Amps — 15-32A Agency Information: UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579,IEC 60269-6 gPV, CSA. CCC pending. Typical Applications • Photovoltaic systems Catalog Numbers Part Number Cylindrical PV-15A14LF PV-20A14LF PV-25A14LF PV-32A14LF Cylindrical with Tags PV-15A14L-T PV-20A14L-T PV-25A14L-T PV-32A14L-T Current Cylindrical with 10mm Fixings PV-15A14LF10F PV-20A14LF10F PV-25A14LF10F PV-32A14LF10F Rating (Amps) 15 20 25 32 Rated Voltage 1500Vdc 1300Vdc Energy Integrats Iat (A2s) Pre-Arching 14 34 65 105 Total at Rated Voltage 160 400 550 900 Watts Loss 0.8 In 3.2 3.6 4.1 5.7 In 5.8 6.5 7.5 10.4 Time-Current Characteristic Curves—Average Melt Available Current (Amps), DC-Time Constant 1-3ms 66 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Data Sheet: 720139 Solar Fuse Products XL Photovoltaic Fuses 1500Vdc XL Style Photovoltaic Fuses Typical Applications • Photovoltaic systems • Inverters Recomended Fuse Holders • SD1XL-S (suitable for 01 and 1XL) • SD2XL-S (suitable for 2XL) • SD3L-S (suitable for 3L) Specifications Description: A range of XL package fuses specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems (reverse current, multi-array fault). Dimensions: See dimension illustration. Ratings: Volts — 1200Vdc (160A) — 1500Vdc (50-125A, 200-400A) Amps — 63 to 400A: IR — 33kA Part Number/Style Body Bladed Bolted Size PV-50A-01XL-15 PV-50A-01XL-B-15 PV-63A-01XL-15 PV-63A-01XL-B-15 PV-80A-01XL-15 PV-80A-01XL-B-15 01 PV-100A-01XL-15 PV-100A-01XL-B-15 PV-125A-01XL-15 PV-125A-01XL-B-15 PV-160A-01XL-12 PV-160A-01XL-B-12 PV-100A-1XL-15 PV-100A-1XL-B-15 PV-125A-1XL-15 PV-125A-1XL-B-15 1 PV-160A-1XL-15 PV-160A-1XL-B-15 PV-200A-1XL-15 PV-200A-1XL-B-15 PV-125A-2XL-15 PV-125A-2XL-B-15 PV-160A-2XL-15 PV-160A-2XL-B-15 2 PV-200A-2XL-15 PV-200A-2XL-B-15 PV-250A-2XL-15 PV-250A-2XL-B-15 PV-250A-3L-15 PV-250A-3L-B-15 PV-315A-3L-15 PV-315A-3L-B-15 3 PV-355A-3L-15 PV-355A-3L-B-15 PV-400A-3L-15 PV-400A-3L-B-15 Current Rating (Amps) 50 63 80 100 125 160 100 125 160 200 125 160 200 250 250 315 355 400 See Data Sheet 720146 for information on the SD__-S Fuse Holders. Volts 1500Vdc 1200Vdc 1500Vdc 1500Vdc 1500Vdc Energy Integrals I2t (A2s) Pre-Arcing Total @ 1000V 280 1450 420 2250 950 5000 1250 6500 2200 11,500 5000 19,500 1250 6000 1950 9360 4200 20,160 9400 45,120 2200 11,000 5000 25,000 9300 36,000 13,700 68,000 20,000 61,000 38,000 116,000 44,000 136,000 58,000 177,000 Watts Loss 0.8In In 6 26 17 28 18 30 22 38 27 48 24 48 24 43 25 52 30 58 31 61 23 43 26 50 28 56 38 72 35 62 40 72 46 84 50 91 Data Sheet: 720134 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 67 Solar Products Agency Information: UL Listed, Guide JFGA, File E335324. Photovoltaic to UL 2579, IEC 60269-6 gPV, CSA. CCC pending. Features and Benefits • Specifically designed to provide fast-acting protection under low fault current conditions associated with PV systems • High DC voltage rating • Variety of mounting options for flexbility • Demonstrated performance in extreme temperature cycling conditions Solar Fuse Products XL Photovoltaic Fuses Dimensions - mm Bladed - Size 01XL, 1XL, 2XL and 3L Size 01XL 1XL 2XL 3L a 193.8 189.8 204.5 204.9 b 127.8 127.8 128.5 127.5 c 124.6 119.6 119.3 118.3 d 128.6 123.6 123.3 122.3 e 20 20 26 32.3 f 7.9 13.4 14.38 18.7 g 43 51 59.2 73.5 h 40.4 39.8 47.9 60 i 21.3 20 20 22 e 58.3 66.3 74.5 f 164.3 160.3 167.8 g 150.3 146.3 154.8 h 10.4 10.4 10.5 i 20 20 25 e 88.8 f 169.7 g 10.5 h 30 j 5.8 5.8 5.8 6 Bladed - Size 01XL, 1XL, 2XL and 3L Size 01XL 1XL 2XL a 187.6 183.6 191.3 b 127.8 127.8 128.5 c 6 6 6 d 43 51 59.2 Bladed - Size 01XL, 1XL, 2XL and 3L Size 3L a 199.7 b 128.5 c 6 d 73.5 Data Sheet: 720134 68 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Solar Fuse Products XL Photovoltaic Fuses Time Current Curves for 01XL - 1500Vdc Time Current Curves for 1XL - 1500Vdc Solar Products Available Current (Amps), DC-Time Constant 1-3ms Available Current (Amps), DC-Time Constant 1-3ms Time Current Curves for 2XL - 1500Vdc Time Current Curves for 3L - 1500Vdc Available Current (Amps), DC-Time Constant 1-3ms Available Current (Amps), DC-Time Constant 1-3ms Data Sheet: 720134 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 69