APPLICATION Architectural cylinder provides direct and indirect light using energy efficient triple tube fluorescent lamps, and is ideal for outdoor and wet location applications. PRODUCT DATA SERIES C7WVF Wet Location REFLECTOR: High efficiency vertical lamp reflectors maximize light output while Direct / Indirect C ylinder Triple Tube Fluorescent Lamp minimizing glare. A gasketed tempered glass lens is supplied standard. Reflectors are available in specular or matte finish in a variety of colors. Provided with low profile 1/2” flange and black reveal. HOUSING: The cylindrical housing is aluminum finished to an architectural grade. Standard finish is matte white epoxy powder coat. Other standard and custom finishes are available. Top of housing is lensed and gasketed for wet location applications. Bottom lamp and ballasts are accessible from below, and the top lamp is accessible from above MOUNTING: Wall mount bracket mounts to 4” octagonal junction box. Wet location wall gasket provided ELECTRICAL: Dual lamp 120 to 277 volt input 50 to 60 Hz electronic ballasts are programmed start, under 10% THD and mounted within the cylinder. ETL/CETL Wet Location Listed. Emergency battery pack not available. SOCKET: Positive latch 4 pin thermoplastic. LAMP DATA: LAMP WATTSBASE BALLASTLUMENS 26 32 42 Triple Tube 4-Pin GX24q-3 GX24q-3 GX24q-4 Elec. Elec. Elec. 1800 2400 3200 Osram/Sylvania, initial lumens (delta/ hex lamp) 12.00" For Wet Locations Manufactured and tested to UL#1598 and CSA standards. Note: Suitable for wet location. 8.19" / 6VFSCLPF Catalog #: C7WVF Example: C7WVF226TE4 Fixture Series 3.63" Example: 6VFSCLPF Lamp/Wattage Ballast/Voltage Options E4 / Electronic 120/277V See Options Below Trim Trim Finish QTYTYPE C7WVF (Wall Mount) 2 26T Triple 2 32T Triple 6VF SCLPF – Soft Specular Clear Alzak with Polished Flange 2 42T Triple For other finishes, consult reflector section. Optional Finishes Suffix # q Black Cylinder Housing............... – B q Bronze Cylinder Housing............. – Z q Galvanite..................................... – GAL Fixture: Project: Options q Satin Aluminum................. – SA q Metallic Aluminum............. – MA Type: q F =Fuse All products are manufactured in accordance with U.L. standard 1598. Suitable for use in damp locations. All Pathway® products meet or exceed requirements as established by the National Electrical Code. Specifications subject to change without notice. Alzak® is a registered trademark of Alcoa. Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591 voice 800.342.0592 • fax 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com Series C7WVF – Wet Location Direct/Indirect Cylinder Triple Tube Fluorescent Lamp 24.07" 7.50" SF4.0 UUUEUB SERIES C7WVF – Direct/ Indirect 8” x 22” Cylinder Triple Tube Fluorescent Lamp DOWNLIGHT - FLOOD DISTRIBUTION PERFORMANCE DATA 1 X 32 WATT HEX LAMP Nadir FC 36 15° FC Diameter 29 3.0’ 13 Reflector Finish 6.0’ 8’ 26213.5’ 97.5’ 9’ 19164.0’ 78.5’ 10’ 15124.5’ 59.5’ 11’ 12 12’ 10 5.0’ 4 MULTIPLIER TABLE CEILING TO FLOOR 30° FC Diameter 11.0’ Multiplier Lamp Multiplier Soft Clear 0.97 26 Watt 0.67 Specular Wheat 0.97 32 Watt 1.00 Soft Wheat 0.87 42 Watt 1.33 Specular Black 0.70 Matte White 0.95 Initial Footcandles at 30” Work Plane UP AND DOWN COMMON PHOTOMETRICS Series C7WVF – Direct/Indirect 8” x 22” Cylinder Triple Tube Fluorescent Lamp UP LIGHT SF4.0 CUMMCN CD DISTRIBUTION CANDELA 1750 VERTICAL ANGLE 180 175 165 160 155 150 145 140 135 130 125 120 115 110 105 100 95 90 180° 1500 170° 160° 1250 1000 150° 750 140° 500 130° 120° 110° 250 SMH = 0.94 AVE. LUMINANCE COEFFICIENTS OF UTILIZATION CD 1589 1576 1420 1233 1088 906 638 512 342 228 67 12 0 0 0 0 0 0 PCC .8 PW.7 .5 .3 .1 RCR 0 1 2 3 4 5 6 7 8 9 10 67676767 63626059 60575452 56524947 53484542 50454138 47413835 44393532 42363230 40343027 38322826 PFC = 0.20 EFF.= 56.7% .7 .7 .5 .3 .1 .5 .5 .3 .1 65656565 62615958 59565452 55524946 52484442 49444138 46413835 44383532 41363230 39333027 37312826 .3 .5 .3 .1 626262 585756 545251 504846 464441 434038 403735 373432 353229 333027 312825 606060 565554 525149 494745 454341 424038 393734 373432 343129 322927 302725 .1 .5 .3 .1 575757 545353 514948 474644 444240 413937 393634 363432 343129 322927 302725 0 0 56 52 47 43 40 36 33 31 28 26 24 NARROW BEAM Angle CD/FT2 45°585 55°112 65°7 75°1 85°0 Clear Lamp DOWN LIGHT CD DISTRIBUTION CANDELA 80° 70° 250 60° 500 50° 750 40° 1000 1250 30° 1500 1750 SMH = 0.94 10° 20° VERTICAL ANGLE CD 900 85 0 80 0 75 0 70 0 65 0 60 1 55 67 50 228 45 342 40 512 35 638 30 906 25 1088 20 1233 15 1420 10 1518 5 1576 0 1589 Note: Data calculated using specular clear reflectors. Results may vary due to lamp and ballast variations, as well as ambient temperature and electrical input variance. Data shown are initial footcandles without contribution from redirected light or other sources. PHOTOMETRIC DATA, available on CD in IES format, please contact factory. EFF.= 56.7% Pathway Lighting Products, Inc., P.O. Box 591, Old Saybrook, CT 06475-0591 voice 800.342.0592 • fax 800.207.0090 • www.pathwaylighting.com • e-mail: sales@pathwaylighting.com