IEC Electronic Timers & Protective Relays Multivoltage electronic timers Supply voltage MTCV Delayed ON timers Direct 24-240V AC/DC With transformer Time range 0.6 - 6 sec. 6 - 60 sec. 0.6 - 6 min. 6 - 60 min. Long time delayed ON timers Available contacts Cat. no.(1) List Price, GO-10RT 1 selectable NO-NC 2 selectable NO-NC 1 selectable NO-NC MTCV MTCV2 MTCVT● $61.00 75.00 79.00 MTCVL MTCVL2 MTCVLT● 64.00 78.00 82.00 MTCIV 64.00 MTCCV 65.00 MTCCVT● 83.00 MICV MICV2 MICVT● 65.00 78.00 83.00 METV METVT● 89.00 107.00 Direct 24-240V AC/DC With transformer MTCIV MRDV 2 Technical data. Type see page MTCV 12 MTCVL 12 MTCIV 13 MTCCV 14 MICV 13 METV 15 MRDV 15 Dimensions, see p.37 0.06 - 0.6 sec. 1 selectable NO-NC 0.6 - 6 sec. 2 selectable NO-NC 0.6 - 6 h. 1 selectable NO-NC 6 - 60 h. Delayed ON timer with instantaneous contact Direct 0.6 - 6 sec. 1 timed contact 24-240V AC/DC 6 - 60 sec. + 1 instant contact 0.6 - 6 min. 6 - 60 min. Delayed ON through contact Direct 0.6 - 6 sec. 1 selectable NO-NC 24-240V AC/DC 6 - 60 sec. 0.6 - 6 min. 1 selectable NO-NC With transformer 6 - 60 min. Impulse ON timer Direct 0.6 - 6 sec. 1 selectable NO-NC 24-240V AC/DC 6 - 60 sec. 2 selectable NO-NC 0.6 - 6 min. 1 selectable NO-NC With transformer 6 - 60 min. Star-delta starter timers Direct 24-240V AC/DC 1 - 10 sec. 2 timed With transformer 1 - 60 sec. 2 timed Delayed OFF timers Direct 0.5 - 6 sec. 1 selectable NO-NC 24-240V AC/DC 5 - 60 sec. 1 selectable NO-NC 50 - 600 sec. 1 selectable NO-NC 0.5 - 6 sec. 2 selectable NO-NC 5 - 60 sec. 2 selectable NO-NC 50 - 600 sec. 2 selectable NO-NC With transformer 0.5 - 6 sec. 1 selectable NO-NC (up to 440V) 5 - 60 sec. 1 selectable NO-NC 50 - 600 sec. 1 selectable NO-NC MRDV-6 MRDV-60 MRDV-600 MRDV2-6 MRDV2-60 MRDV2-600 MRDVT-6● MRDVT-60● MRDVT-600● 81.00 81.00 81.00 89.00 89.00 89.00 93.00 93.00 93.00 Contact diagrams. 1 selectable NO-NC 2 selectable NO-NC 2 timed (1) To complete the catalog number, replace the symbol ● with the code corresponding to the voltage. See p.10-11 IEC Electronic Timers & Protective Relays Multivoltage electronic timers Supply voltage MTDV MIFV MIVV MMFV MMFV2 Time range Delayed OFF through contact timer Direct 0.6 - 6 sec. 24-240V AC/DC 6 - 60 sec. With transformer 0.6 - 6 min. 6 - 60 min. Available contacts Cat. no.(1) 1 selectable NO-NC MTDV 1 selectable NO-NC MTDVT● List Price, GO-10RT $56.00 74.00 Symmetric intermittence Direct 0.6 - 6 sec. 1 selectable NO-NC MIFV 108.00 24-240V AC/DC 6 - 60 sec. 2 selectable NO-NC MIFV2 122.00 0.6 - 6 min. 1 selectable NO-NC MIFVT● 126.00 With transformer 6 - 60 min. Asymmetric intermittence, started by connection or pause (choice) Direct 0.6 - 6 sec. 1 selectable NO-NC MIVV 108.00 24-240V AC/DC 6 - 60 sec. 2 selectable NO-NC MIVV2 122.00 0.6 - 6 min. 1 selectable NO-NC MIVVT● 126.00 With transformer 6 - 60 min. Long time asymmetric intermittence, started by connection or pause (choice) 0.6 - 6 min. 1 selectable NO-NC MIVVL 110.00 Direct 24-240V AC/DC 6 - 60 min. 2 selectable NO-NC MIVVL2 125.00 130.00 With transformer 0.6 - 6 h. 1 selectable NO-NC MIVVLT● 6 - 60 h. Multifunction timer –Delayed ON timer –Impulse ON timer –Delayed ON through contact timer –Impulse ON through contact timer –Delayed OFF through contact timer –Impulse OFF through contact timer –Delayed ON and OFF through contact timer –Impulse ON and OFF through contact timer Direct 0.6 - 6 sec. 1 selectable NO-NC MMFV 120.00 24-240V AC/DC 6 - 60 sec. 0.6 - 6 min. 6 - 60 min. Multifunction timer - large 45 mm –Delayed ON timer –Impulse ON timer –Delayed ON through contact timer –Impulse ON through contact timer –Delayed OFF through contact timer –Impulse OFF through contact timer –Delayed ON and OFF through contact timer –Impulse ON and OFF through contact timer Direct 0.6 - 6 sec. 2 selectable NO-NC MMFV2 140.00 24-240V AC/DC 6 - 60 sec. 0.6 - 6 min. 2 selectable NO-NC MMFVT2● 145.00 With transformer 6 - 60 min. Contact diagrams. 1 selectable NO-NC 2 selectable NO-NC Technical data. Type see page MTDV 16 MIFV 17 MIVV 18 MIVVL 19 MMFV 20 Dimensions, see p.37 3 (1) To complete the catalog number, replace the symbol ● by the code corresponding to the voltage. See p.10-11 IEC Electronic Timers & Protective Relays Available supply voltages Legend: ●=Available ▲=Recommended stock Shaded columns indicate UL approved devices, except where marked with * Direct supply Current AC (50/60 Hz) /DC Voltage 24- Supplied with internal transformer AC (50/60Hz) 24 48 240 Cat No. Code AD AG AJ 240 230 AJ AK ● ● ▲ ● DINIL02E ● ● ▲ ● DINIL03 ● ● ▲ ● DINIL03E ● ● ▲ ● AM 400 EN AR AU ● ● ● ● ● ● ● ● ▲ ▲ ● ● ▲ ● ● ▲ ● ● MIVVLT ▲ ● ● MIVVT ▲ ● ● ▲ ● ● ▲ ● ● ▲ ● ● MTCVLT ▲ ● ● MTCVT ▲ ● ● METVT MICV ▲ MICV2 ▲ MICVT MIFV ▲ MIFV2 ● MIFVT MIVV ▲ MIVV2 ● MIVVL ▲ MIVVL2 ● MMFV ▲ MMFV2 ▲ MMFVT2 MRDV ▲ MRDV2 ▲ MRDVT MTCCV ▲ MTCCVT 10 125 DINIL02 METV None 110 110 125 200 220 240 380 MTCIV ▲ MTCV ▲ MTCV2 ▲ MTCVL ▲ MTCVL2 ▲ MTDV ▲ IEC Electronic Timers & Protective Relays METV - Star-delta starter timer MRDV - Delayed OFF timer Function Function Electronic relay timed in steps whose purpose is to control star-delta starting. When supply voltage is applied to the A1-A2 terminals, the star contact (17-18) closes for an adjustable time between 1-10 sec. or 6-60 sec. (selectable). When this time is up, it opens, there is a pause and then the delta contact connects (17-18). The standard pause time is about 100ms. Times are set by front potentiometer controlling an ASIC specially designed for this group of relays. This allows for excellent presicision and repeatability features. Electronic relay whose output contact instantly connects when supply voltage is applied to terminals A1-A2. It disconnects with an adjustable delay from the moment the relay loses supply voltage. There are several types depending on the range of timers. Diagram Us Diagram A1 Us 15 A1-A2 A1-A2 t A1 A1 17 16 18 100ms 18 A2 18 18 28 A2 Technical characteristics 1 - 10s 6 - 60s Technical characteristics Type Number of selectable NO-NC contacts Output contacts Rated insulation voltage AC DC Thermal current Ith Utilization category AC15 Rated voltage Ue Rated current Ie Utilization category DC13 Rated voltage Ue Rated current Ie Supply voltages Un AC/DC (direct) AC (with transformer) % (mA) (mA) (VA) Test voltage (between input, output and ground) Switch ON response Reset time between 2 cycles Repeat accuracy with 0.85 - 1.1 Un Weight METV METVT 2 400V 250V 6A 120/240V 2.5/1.3A 110/220V 0.2/0.1A 24-240V – – – – 110-125V 200-240V 380-440V 50/60 Hz +10 / -20 +10 / -15 50 (at 24V) – 12 (at 240V) – – 3.5 4 kV 100 ms 100 ms 2% 0.130, .28 lbs. Conformity to standards VDE 0106 VDE 0110 EN 50001 15-18 16 A2 17-28 28 Frequency Supply voltage tolerance Consumption td A2 17-18 17 A1 15 EN 50002 CSA C 22.2 N° 14 UL 94 UL 508 IEC 255.5 Type Number of selectable NO-NC contacts Output contacts Rated insulation voltage Ui AC DC Thermal current Ith Utilization category AC15 Rated voltage Ue Rated current Ie Utilization category DC13 Rated voltage Ue Rated current Ie Supply voltages (Un) AC/DC (direct) AC (with transformer) MRDV 1 MRDV2 2 MRDVT 1 400V 250V 6A 120/240V 2.5/1.3A 110/220V 0.2/0.1A 24-240V – – – 24-240V – – 110-125V – 200-240V – 380-440V 50/60 Hz Frequency +10 / -15 Supply voltage tolerance % +10 / -20 +10 / -20 – Consumption (mA) 50 (at 24V) 50 (at 24V) – (mA) 15 (at 240V) 15 (at 240V) – – 3.5 (VA) 4 kV Test voltage (between input, output and ground) 250 ms (1) Switch-ON responce time 0.5 - 600s Switch-OFF responce time 250 ms Reset time between 2 cycles 5% Repeat accuracy with 0.85 - 1.1 Un 0.130, .28 lbs. Weight Conformity to standards VDE 0106 VDE 0110 EN 50002 EN 50042 CSA C 22.2 N° 14 UL 508 (1) For 24V DC = 300 ms. For ambient conditions data, see p.36, Table 2. For ambient conditions data, see p.36, Table 1. Note: The relays have a green LED that lights when the relay is energized (flashing during the timing) and a red LED that lights when the output contact is made. IEC 255.5 IEC 947.5.1 UNE 20-119 15