Data Sheet 2 - Carlton

advertisement
OEM LOADCENTER
INTERIOR ASSEMBLIES
CIRCUIT BREAKERS
AND ACCESSORIES
OEM Loadcenter Interior Assemblies
OEM INTERIOR
ASSEMBLIES
Page 1
Type CH Index
Type BR Index
page(s)
page(s)
Type CH OEM Loadcenter
Interior Assemblies ....................................... 4
Type BR OEM Loadcenter
Interior Assemblies ..................................... 22
Type CH Loadcenter Accessories ..................... 5
Type BR Loadcenter Accessories ................... 23
Type CH Circuit Breakers .................................. 6
Type BR Circuit Breakers ................................ 24
Plug-On .......................................................... 7
Plug-On ............................................... 25 & 30
Plug-On Special Application ................... 7-11
Plug-On Special Application ...... 26, 27, & 30
Accessories ................................................. 12
Plug-On Duplex, Quadplex .................. 28, 29
Type CH Interior Assemblies
Single-Phase, Single-Row
Copper Bus, 70 and 125 Amp .................... 13
Single-Phase, Double-Row
Copper Bus, 125, 200 and 225 Amp ..... 14-18
Three-Phase, Double-Row
Copper Bus, 125 and 225 Amp ............. 19-21
Surge Protectors ............................................. 46
Accessories ................................................. 31
Type BR Interior Assemblies
Single-Phase, Single-Row
Aluminum Bus, 70 and 125 Amp ......... 32, 33
Single-Phase, Double-Row
Aluminum Bus,
125, 200 and 225 Amp ........................... 34-39
Single-Phase, Double-Row
Copper Bus, 125 and 200 Amp ............ 40, 41
Three-Phase, Double-Row
Aluminum Bus,
125, 150, 200 and 225 Amp ................... 42-44
Three-Phase, Double-Row
Copper Bus, 125 and 200 Amp .................. 45
Surge Protectors ............................................. 46
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OEM INTERIOR
ASSEMBLIES
Page 2
General
Quality
As a leader in the electrical distribution equipment business, CutlerHammer has a unique product
offering for equipment manufacturers,
panel builders and virtually any OEM
that has a need for power distribution
within their equipment. The OEM
interior offering consists of a wide
variety of power distribution options
utilizing components from CutlerHammer’s CH and BR Loadcenter
product lines. With high-volume,
standardized products, OEMs can
expect to receive high-quality
products in configurations meeting
virtually any power distribution need.
Built in our ISO 9002 certified manufacturing facilities, customers can be
assured of the process quality in place
for the manufacture of these products.
Utilizing the latest in computercontrolled plating, painting, molding,
stamping and welding processes,
our customers have come to expect
consistent high quality from shipment
to shipment.
Coupled with Cutler-Hammer’s
expertise in circuit breaker design
and manufacturing, our OEM interiors
provide solid power distribution and
circuit protection in a compact, easyto-install package. Interiors are offered
from 2 to 42 circuits, and from 70 to
225 amperes.
Ordering Information
Cutler-Hammer OEM interiors are as
easy to order as they are to install.
Customers place orders by catalog
number in multiples of the standard
package quantities. The products are
either stocked in Cutler-Hammer
warehouses or are shipped directly
from the plant. For those panels
shipping directly from the plant,
shipping lead time is 10 working days.
Distributors should refer to VISTA or
the Cutler-Hammer Price and
Availability Digest for pricing. For
interiors not shown in this catalog,
contact your local Cutler-Hammer
sales engineer or the Customer
Support Center at 1-800-356-1243.
Two Products Offer
Design Flexibility
As a manufacturer of two lines of
loadcenters, we are in a unique
position to offer the broadest range
of interiors in the market. Each line
has its own unique characteristics
that appeal to various segments of
the market. OEM interiors are UL
recognized components and are listed
in either of the following UL files:
E8741 or E52977.
The interiors are designed for either
horizontal (single-row breaker
mounting), or vertical (double-row
breaker mounting). To comply with
National Electrical Code® (NEC)
requirements if mounted horizontally,
when the breaker is ON, the handle
should be in the UP position. When
mounted vertically, the handle toggles
from left to right, so this is not a concern.
Type CH
The CH interiors feature 100% copper
bus and use the CH 3/4-inch wide
(19.1 mm) circuit breaker, which
minimizes panel space. Recognized
by contractors for its sturdy design,
the CH interior will appeal to those
customers seeking an industrial
quality bolted bus bar and the space
saving of 1/4-inch (6.4 mm) per bus
stab. With a typical 12 circuit CH
interior, this space savings amounts
to an 1-1/2 inch (38.1 mm) savings
over its 1-inch (25.4 mm) counterparts.
The stab rating of the CH interiors is
140 amperes maximum, meaning that
the handle rating of breakers mounted
across from one another may not
exceed 140 amperes.
Type BR
The BR interiors are manufactured of
formed, plated aluminum or copper,
and use the Cutler-Hammer Type BR
1-inch wide (25.4 mm) circuit breaker.
This design affords customers the
most circuit flexibility as many of
these interiors allow the installation
of standard 1- and 2-pole breakers
as well as duplex (2 poles in a 1-inch
space, 25.4 mm), or quadplex (4 poles
in a 2-inch space, 50.8 mm) breakers.
The stab rating of the BR interiors is
200 amperes maximum, meaning that
the handle rating of the breakers that
are mounted across from one another
may not exceed 200 amperes.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OEM Loadcenter Interior Assemblies
OEM INTERIOR
ASSEMBLIES
Page 3
Specifications, Listings
Underwriters Laboratories Inc. Listing
Lighting and Appliance Panelboards
Class CTL
All grounding bars manufactured
comply with Underwriters Laboratories
Inc. standards and are listed under
Guide No. DHJR, File E31424, Volume W,
Section 17.
Lighting and appliance branch circuit
panelboards are defined in NEC Article
384 as “One having more than 10% of
its overcurrent devices rated 30
amperes or less for which neutral
connections are provided.” Article 384
also limits the number of overcurrent
devices (branch circuit poles) to a
maximum of 42 in any one cabinet.
When the 42 poles are exceeded, two
or more separate panels are required.
NEC Paragraph 384-15 requires branch
circuit panelboards to be provided
with physical means to prevent the
installation of more overcurrent
devices than the number of which the
enclosure was designed, rated and
approved. Class CTL duplex, quadplex
and twin breakers (identified by a
catalog number prefix BD, BQ, BQC
and CHT) are equipped with a UL
listed rejection tab over the line
terminal. All OEM interiors have
appropriately notched stabs to accept
these rejection tab Class CTL breakers.
Duplex, quadplex and twin breakers
manufactured without the rejection
tab (identified by a catalog number
prefix BR, BRD and CHNT) are
available for replacement purposes
in older interiors.
All circuit breakers 10 amperes and
larger comply with the Underwriters
Laboratories Inc. “Standard for Branch
Circuit and Service Circuit Breakers”
UL489, Guide No. 60 10.2 File E31424;
and “Requirements for Wire Connectors and Soldering Lugs” UL486B,
Guide No. 461 10-C File E7830.
All Cutler-Hammer breakers where
marked, are suitable for use with
60/75°C rated wire, unless otherwise
specified.
All devices comply with the 22,000 AIC
– 10,000 AIC UL series connected
components File DKSY2 of the
Recognized Components Index.
Federal Specifications
All loadcenter enclosures meet
Federal Specifications W-P-115b,
Type 1, and Class 2 requirements.
All 120/240V breakers, both 1-inch
(25.4 mm), 1/2-inch (12.7 mm) and
3/4-inch (19.1 mm) per pole meet the
requirement of Federal Specifications
W-C 375B/Gen Type 1.
Canadian Standards Association Listing
All 1-pole and 2-pole, 120/240V
breakers, both 1-inch (25.4 mm),
1/2-inch (12.7 mm) and 3/4-inch
(19.1 mm) per pole, 225 ampere
maximum, are listed as certified by
the Canadian Standards Association,
Guide No. 69-11.19, Class 1432,
File 18328.
NEC
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
5
1
4
8
3
TYPE
CH ASSEMBLIES
OEM Loadcenter Interior Assemblies
Page 4
Type CH OEM Loadcenter Interior Assemblies
Ampere
Rating
Maximum Number
1-Inch (24.5 mm)
Spaces
UL
File
Single Poles Reference
Main Terminal Wire Size Range
(Per Phase)
Cu/Al 60°C or 75°C
Standard
Package
Quantity
Catalog
Number
Diagram Reference
Number
Page
Single-Phase Single-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
70
2
2
E8741
(1) #8–#2 AWG Cu/Al
1
CH9MB270
1
13
125
2
2
E8741
(1) 2/0–#6 AWG Cu/Al
20
CH2L125INT
2
13
14
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
125
4
4
E8741
(1) 2/0–#14 AWG Cu/Al
20
CH4L125INT
3
125
8
8
E8741
(1) 2/0–#6 AWG Cu/Al
20
CH8L125INT
4
14
125
12
12
E8741
(1) 2/0–#6 AWG Cu/Al
20
CH12L125INT
5
15
125
16
16
E8741
(1) 2/0–#6 AWG Cu/Al
20
CH16L125INT
6
15
200
12
12
E8741
(1) 300 kcmil–#4 AWG Cu/Al
20
CH12L200INT
7
16
200
16
16
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH16L200INT
8
16
225
24
24
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH24L225INT
9
17
225
32
32
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH32L225INT
10
17
225
42
42
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH42L225INT
11
18
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
125
12
12
E8741
(1) 2/0–#6 AWG Cu/Al
10
CH12L3125INT
12
19
125
18
18
E8741
(1) 2/0–#6 AWG Cu/Al
10
CH18L3125INT
13
19
125
24
24
E8741
(1) 2/0–#6 AWG Cu/Al
10
CH24L3125INT
14
20
225
24
24
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH24L3225INT
15
20
225
30
30
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH30L3225INT
16
21
225
42
42
E8741
(1) 300 kcmil–#4 AWG Cu/Al
10
CH42L3225INT
17
21
Catalog Numbering System
CH 4 L 3 125 INT
Breaker Type
Maximum Single Poles
Main Lug
OEM Interior
Ampere Rating
Single-Phase: Blank / Three-Phase: 3
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
Loadcenter Accessories
CH ASSEMBLIES
Page 5
Neutral Assemblies
Ampere
Rating
UL
File
Reference
Main Incoming Terminal
Wire Size Range
60°C or 75°C
125
E52977
#6–1/0 AWG Cu
#6–2/0 AWG Al
125
E52977
125
Number of Terminals
#6–1/0 AWG Cu
#6–2/0 AWG Al
Standard
Package
Quantity
10
–
20
10NEU125B
1
5.938 (150.83)
5.400 (137.16)
#6–1/0 AWG Cu
#6–2/0 AWG Al
17
–
20
17NEU125B
1
8.388 (213.06)
7.850 (199.40)
E52977
#6–1/0 AWG Cu
#6–2/0 AWG Al
20
–
20
20NEU125B
1
9.438 (239.73)
8.900 (226.06)
225
E52977
#1–300 kcmil Cu/Al
24
1
20
24NEU225B
2
10.913 (277.19) 10.300 (261.62)
225
E52977
#1–300 kcmil Cu/Al
35
1
20
35NEU225B
2
15.813 (401.65) 15.200 (386.08)
125
—
—
4
2
1
BINA
3
2.266 (57.56)
#14–4 AWG
Cu/Al
Figure 1
Catalog
Number
Dimensions – Inches (mm)
Figure Overall Length
A
Mounting
B
0.594 (15.09)
Figure 2
A
.269
(6.83)
A
.344
(8.74)
B
.844
(21.44)
.269
(6.83)
B
.844
(21.44)
1.750
(44.45)
CL of Mounting Hole
CL of Mounting Hole
2.360
(59.94)
2.860
(72.64)
2.360
(59.94)
Figure 3
.120
(3.05)
A
.250
(6.35)
CL of Mounting Hole
1.182
(30.02)
.750
(19.05)
.688
(17.47)
CL
of
Mounting
Hole
.182 Diameter
(4.62)
.156
(3.96)
1.750
(44.45)
1.187
(30.15)
B
.344
(8.74)
2.000
(50.80)
Add-on Lugs for Neutral Assemblies
Description
Wire Size Range
Cu/Al 60°C or 75°C
Ordering
Quantity 1
Catalog
Number
Neutral/Ground Lug
Add-On Neutral or Ground Lug
#2/0 Maximum
1
#3/0 Maximum
1
300 kcmil Maximum 1
NL20
NL30
NL300
Length
Inches (mm)
Ordering
Quantity 1
Catalog
Number
2.54 (64.5)
3.59 (91.2)
4.29 (109.0)
5.34 (135.6)
4.61 (117.1)
5.69 (144.5)
6.74 (171.2)
8.14 (206.8)
9.19 (233.4)
5.78 (146.8)
1
1
1
1
1
1
1
1
1
1
GBK5 2
GBK520 2
GBK10 2
GBK1020 2
GBK13 2
GBK14 2
GBK1420 2
GBK21 2
GBK2120 2
BRGBK39512 34
GBK14
Ground Bar Kits
f
d
f
f
f
k
f
d
f
k
f
f
f
dssssds
dssssdsj
dssssdssssss
dssssdssssssj
dssssdssssssssss
dssssdssssssssssj
dssssdsssssssssssssssss
dssssdsssssssssssssssssj
ofodofooofodofooofo
1
2
3
4
Must be purchased in multiples of ordering quantities indicated.
Distance between mounting holes is 1-3/4 inches (44.5 mm).
For 1- and 3-phase 400 and 600 ampere applications.
Distance between mounting holes is 2-11/32 inches (59.5 mm).
BRGBK39512
Ground Bar Legend
s (3) #14 – #10 Cu/Al or (1) #14 – #4 Cu/Al
j (1) #6 – 2/0 Cu/Al
o (1) #14 – #6 Cu/Al or (2) #14 – #12 Cu/Al
(1) 1/0 – 14 or (3) #10 – 12 Cu/Al
(1) #14 – 1/0 Cu/Al or (3) #14 – #10 Cu/Al
f (1) #6 – 14 Cu/Al or (2) #1/0 – 14 Cu/Al
d Mounting Hole
fk
Description
(See Legend)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH CIRCUIT
BREAKERS
Page 6
CH Circuit Breakers
Special Application Breakers
CH-HM Breakers
Cutler-Hammer Type CH plug-on
breakers are a 3/4-inch (19.1 mm)
design with a UL listed 10 kA interrupting rating. CH breakers can be used as
main or branch disconnect devices.
Several ratings are SWD and HACR
approved. Typical ampacity range for
CH breakers is 15 to 150 amperes.
As the name implies, these devices are
designed for special applications as required by the National Electrical Code.
CH-HM breakers are designed with
high magnetic trip settings. Singleand 2-pole CH-HM breakers (“HM”
suffix) rated 15 and 20 amperes are
recommended for circuits with
inherently high inrush currents.
CH-GF People Protection Breakers
Cutler-Hammer Type CH-GF (ground
fault circuit breakers) combine stateof-the-art electronic technology with
a circuit breaker mechanism in a
compact 3/4-inch (19.1 mm) package.
The CH-GF automatically senses hot
wire-to-ground faults in a 4 to 6 mA
range and disconnects the power, thus
providing an extra margin of safety
beyond that of conventional circuit
breakers. CH-GF applications include
bathrooms, cellar outlets, swimming
pools, outdoor branch circuits and
kitchen branch circuits. Available in UL
listed 120 and 120/240V ratings. CutlerHammer also offers non-UL listed
ground fault breakers for international
applications as well as ground fault
devices for equipment protection.
CH-EPD Equipment Protection
Breakers
The Cutler-Hammer Type CH-EPD
device is similar to the CH-GP except
that it is designed to protect equipment (not people) against damage
from arcing ground faults. It is
available with a 30 mA trip level.
Applications include infrared heating
equipment, process control equipment, etc.
Neutral Switching Breaker
Primary application for the CutlerHammer switching neutral breaker is
for protection of process equipment
such as gas pumps that utilize
flammable liquids. Non-automatic
pole breaks the neutral power leg,
minimizing the danger of arc conditions.
2-Pole Breakers 120V or More to Ground
Used on Delta distribution systems,
these Type CH breakers are applied on
phase legs where voltage-to-ground is
above 120V.
Arc Fault Circuit Interrupters (AFCIs)
Reduce the risk of fire by detecting
and interrupting electrical arcing faults
which standard thermal magnetic
breakers cannot. For more information, see page 9.
Calibrated one-piece
bimetal for reliable
thermal protection.
Heavy-duty over-center
toggle spring to ensure
a quick and reliable
“make-break” action.
Unique two-position
trip. Helps to eliminate
nuisance callbacks,
breaker trips to “OFF,”
homeowner simply
turns to “ON,” no
reset required.
CH-M50 Breakers
CH-M50 breakers are designed to
operate at a maximum temperature
of 50°C. Single- and 2-pole CH-M50
breakers (“M50” suffix) rated 15 to
50 amperes are recommended for
applications where the ambient
temperatures are above 40°C.
CHP Breakers
CHP breakers are designed with a
three-position commercial trip (ontripped-off). Single-, 2- and 3-pole
CHP breakers rated 10 to 70 amperes
are recommended for applications
requiring a breaker center trip position.
Magnetic armature –
assists in the instantaneous tripping for short
circuit protection.
All internal metal
components are plated
to provide a 100% noncorrosive circuit breaker.
Magnetic armature placement spring ensures consistent low instantaneous
trip on 15 and 30 ampere
breakers.
Plated steel latch lever
provides load force for
quick and reliable tripping
during a thermal or
magnetic trip condition.
Calibration screw (under
UL label) provides for
accurate and predictable
protection every time.
Factory calibrated.
Heavy duty tin-plated
copper box lugs for load
termination. Rated for two
60/75 °C wire conductors.
Latch spring provides
consistent relatching
operation of the breaker
trip mechanism.
Large gas port allowing
short circuit gases to safely
exit the circuit breaker.
Tin-plated copper
contact stabs for
good conductivity
and quick installations.
Contact clip spring
for solid bus stab
connection. Eliminates
expansion during environmental changes.
Large silver tungsten
contacts for good
contact wear and
conductivity.
Zinc-plated magnetic
pole piece – works with
magnetic armature to
provide instantaneous
tripping for short circuit
protection.
CH Breaker Section View
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Glass polyester base and
cover for superior construction and durability.
One-piece molded base
allows for repeatable
quality every time.
Plug-On Circuit Breakers
Special Application Plug-On Circuit Breakers
TYPE
CH CIRCUIT
BREAKERS
Page 7
Plug-On Circuit Breakers, Type CH
10,000 Amperes Interrupting
Capacity 120, 120/240
or 240V AC
Plug-on Circuit Breakers
1
2
3
4
5
6
7
8
9
For 1- and 2-pole breakers.
Solid and stranded wire can be used together.
For 3-pole breakers.
Switching duty rated.
HACR rated.
1-pole 60 – 70 amperes, 2-pole 80 – 125
amperes, 3-pole 40 – 100 amperes.
1-pole 40 – 50 amperes, 2-pole 40 – 70
amperes.
2-pole 150 amperes.
CH2150 requires 4-pole spaces and is
not suitable for use on 3-phase panels,
not CSA certified.
Type CH Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AIC
Ampere
Rating
Wire Size Range
Cu/Al
60ºC or 75°C
1-Pole 120/240V AC
Requires One
3/4-inch (19.1 mm)
Space
2-Pole 120/240V AC
Common Trip
Requires Two
3/4-inch (19.1 mm)
Spaces
3-Pole 240V AC
Common Trip
Requires Three
3/4-inch (19.1 mm)
Spaces
10 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
Catalog Number
10
15
20
25
30
(1) #14 – 8 1
(2) #14 – 10 12
(1) #14 – 6 3
CH110
CH115 45
CH120 45
CH125 5
CH130 5
CH210
CH215 5
CH220 5
CH225 5
CH230 5
CH310
CH315 5
CH320 5
CH325 5
CH330 5
35
#14 – 2 1
#14 – 6 3
CH135 5
CH235 5
CH335
#10 – 1/0 6
#14 – 2 7
#3/0 8
CH140 5
CH145 5
CH150 5
CH160 5
CH170
—
—
—
—
—
—
CH240 5
CH245 5
CH250 5
CH260 5
CH270
CH280
CH290
CH2100
CH2110
CH2125
CH2150 9
CH340 5
CH345 5
CH350 5
CH360 5
CH370
CH3080
CH3090
CH3100
—
—
—
40
45
50
60
70
80
90
100
110
125
150
CH Neutral Switching Breakers — 10,000 Amperes Interrupting Capacity — 120 or 120/240V AC
Type CH Neutral Switching Breakers, 3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Used to open the neutral along power line(s) for applications of gas pumps.
Ampere
Rating
15
20
30
40
50
1
2
Wire Size
Range
Cu/Al
60ºC or
75°C
#14 – 8
2-Pole
120V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
(Hot leg)
Neutral Out
Neutral In
3-Pole
120/240V AC
Common Trip
Requires Three 3/4-inch
(19.1 mm) Spaces
1 per Individual Carton
1 per Individual Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CH215SW
CH220SW
CH230SW
CH240SW
CH250SW
1
1
1
1
1
Phase
Phase
Neutral Out
Neutral In
CH315SW 2
CH320SW 2
CH330SW 2
CH340SW 2
CH350SW 2
For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space.
Switching duty rated.
CH-HID Circuit Breakers — 10,000 Amperes Interrupting Capacity — 120, 120/240 or 240V AC
Type CH-HID Circuit Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AIC
Suitable for use in circuits for fluorescent and High Intensity Discharge lighting. Also suitable for HACR applications.
Ampere
Rating
15
20
30
1
Wire Size
Range
Cu/Al
60ºC or
75°C
#14 – 8
1-Pole
120/240V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
3-Pole
240V AC
Common Trip
Requires Three 3/4-inch
(19.1 mm) Spaces
10 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CH115HID
CH120HID
CH130HID
CH215HID
CH220HID
CH230HID
1
Catalog Number
CH315HID
CH320HID
CH330HID
CH215HID is rated for 120/240V.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH CIRCUIT
BREAKERS
Special Application Plug-On Circuit Breakers
Page 8
Plug-On Ground Fault Circuit
Breakers, Type CH 10,000 Amperes
Interrupting Capacity 120
or 120/240V AC
Type CH Ground Fault Circuit Breakers (5 Milliampere)
3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Ampere
Rating
15
20
25
30
35
40
45
50
60
1
Type CH 1-Pole
Type CH 2-Pole
Ground Fault Application Notes
Single-pole Type CHGFIs are designed
for use in 2-wire, 120V AC circuits.
Figure 4 shows a typical wiring
configuration.
Two-pole Type CHGFIs are designed
for use in 3-wire, 120/240V AC circuits,
120V AC multiwire circuits employing
common, neutral and 2-wire, 240V AC
circuits obtained from a 120/240V AC
source.
Figure 5 and Figure 6 illustrate
typical wiring configurations for
120/240V AC multiwire circuits.
Figure 7 depicts a 240V AC, 2-wire
circuit. Note the “panel neutral”
conductor connects to the neutral bar,
even though the neutral is not included
in the load circuit. This connection is
necessary to supply a 120V AC power
source to the ground fault sensing
circuit.
The figures are shown with a 120/240V
AC, single-phase, 3-wire power source,
but are also applicable to a 120/208V AC,
3-phase, 4-wire power supply. For all
figures the electrical operation of the
Type CHGFI is not affected by the
equipment ground.
Wire Size
Range
Cu/Al
60ºC or
75°C
AWG
#14 –
61
1-Pole
120V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
120/240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
1 per Shelf Carton
1 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CH115GF
CH120GF
CH125GF
CH130GF
—
—
—
—
—
CH215GF
CH220GF
CH225GF
CH230GF
CH235GF
CH240GF
CH245GF
CH250GF
CH260GF
60 ampere breaker listed for 75°C Cu wire only.
Type CH Ground Fault Equipment Protection Circuit Breakers (30 Milliampere)
3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Ampere
Rating
15
20
25
30
40
50
60
1
Wire
Size
Range
Cu/Al
60ºC or
75°C
AWG
#14 – 6 1
1-Pole
120V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
120/240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
1 per Shelf Carton
1 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CH115EPD
CH120EPD
CH125EPD
CH130EPD
—
—
—
CH215EPD
CH220EPD
—
CH230EPD
CH240EPD
CH250EPD
CH260EPD
60 ampere breaker listed for 75°C Cu wire only.
Figure 4. 1-Pole
Figure 6. 2-Pole
Figure 5. 2-Pole
Figure 7. 2-Pole
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
Special Application Plug-On Circuit Breakers
CH CIRCUIT
BREAKERS
Page 9
Plug-On Arc Fault Circuit
Breakers, Type CH 10,000 Amperes
Interrupting Capacity 120
or 120/240V AC
Type CH FIRE-GUARD™ AFCI Circuit Breakers
3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Poles
Ampere
Rating
Configuration
Catalog
Number
Wire Size Range Cu/Al
60ºC or 75ºC AWG
1-Pole
10 kAIC
15
AFCI
AFCI with GFCI
CH115AF
CH115AFGF
#14 – 6
20
AFCI
AFCI with GFCI
CH120AF
CH120AFGF
#14 – 6
15
AFCI Common Trip
AFCI Independent Trip
AFCI Common Trip with GFCI
CH215AF
CH215AFIT
CH215AFGF
#14 – 6
20
AFCI Common Trip
AFCI Independent Trip
AFCI Common Trip with GFCI
CH220AF
CH220AFIT
CH220AFGF
#14 – 6
2-Pole
10 kAIC 12
1
Type CH 1- and 2-Pole
AFCI Circuit Breakers
2
Common trip refers to 2-pole 240V load application sourced by 120/240V AC (see Figure 10).
Independent trip refers to 2-pole shared neutral circuits (see Figure 9 and Figure 11).
120/240V AC
Source
N A B
120/240V AC
Source
N A B
Line B
Line B
2 Pole
1 Pole
Line A
Neutral
120V
Duplex
Receptacle
Neutral
Neutral
Equipment Ground
Equipment Ground
Figure 8. 1-Pole Single 120V Load
Application Sourced by 120/240V AC
120/240V AC
Source
N A B
240V
Duplex
Receptacle
Figure 10. 2-Pole 240V Load Application
Sourced by 120/240V AC
120/240V AC
Source
N A B
Line B
Line B
Line A
2 Pole
Neutral
Neutral
2 Pole
2-120V
Duplex
Receptacles
Neutral
Line A
Neutral
120V Duplex
Receptacle
(With Line Side
Jumper Removed)
Equipment Ground
Equipment Ground
Figure 9. 1-Pole Shared Neutral with
Multi-Duplex Receptacle Application
Figure 11. 2-Pole Shared Neutral with Duplex
Receptacle Application
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH CIRCUIT
BREAKERS
Special Application Plug-On Circuit Breakers
Page 10
CHP Commercial Breakers — 10,000 Amperes Interrupting Capacity
120, 120/240 or 240V AC
Note: CHP Breakers feature on-off and trip positions for commercial applications
Type CHP Breakers, 3/4-inch (19.1 mm) per Pole 120, 120/240 or 240V AC, 10,000 AIC
Note: CHP Breakers offer on-off and trip positions for commercial applications
Ampere
Rating
2
3
4
5
6
7
81
10 12
63
1-Pole
120/240V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
120/240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
3-Pole
240V AC
Common Trip
Requires Three 3/4-inch
(19.1 mm) Spaces
10 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
Catalog Number
CHP110
CHP115 45
CHP120 45
CHP125 5
CHP130 5
CHP210
CHP215 5
CHP220 5
CHP225 5
CHP230 5
CHP310
CHP315 5
CHP320 5
CHP325 5
CHP330 5
10
15
20
25
30
(1) #14 –
(2) #14 –
(1) #14 –
35
#14 – 2 1
#14 – 6 3
CHP135 5
CHP235 5
CHP335 5
#10 – 1/0 6
#14 – 2 7
CHP140 5
CHP145 5
CHP150 5
CHP160 5
CHP170
—
—
—
—
—
CHP240 5
CHP245 5
CHP250 5
CHP260 5
CHP270
CHP280
CHP290
CHP2100
CHP2110
CHP2125
CHP340 5
CHP345 5
CHP350 5
CHP360 5
CHP370
—
—
CHP3100
—
—
40
45
50
60
70
80
90
100
110
125
1
Wire Size Range
Cu/Al
60ºC or 75°C
AWG
For 1- and 2-pole breakers.
Solid and stranded wire can be used together.
For 3-pole breakers.
Switching duty rated.
HACR rated.
1-pole 60 – 70 amperes, 2-pole 80 – 125 amperes, 3-pole 40 – 100 amperes.
1-pole 40 – 50 amperes, 2-pole 40 – 70 amperes.
CHP-GFCI Circuit Breakers — 10,000 Amperes Interrupting Capacity
120 or 120/240V AC
Note: CHP Breakers offer on-off and trip positions for commercial applications.
Type CHP-GFCI Breakers — 5 Milliampere — 3/4-inch (19.1 mm)
per Pole 120 or 120/240V AC, 10,000 AIC
Note: CHP Breakers offer on-off and trip positions for commercial applications.
Ampere
Rating
Wire Size Range
Cu/Al
60ºC or 75°C
AWG
1-Pole
120V AC
Requires One 3/4-inch
(19.1 mm) Space
Ground Fault Application Notes
Single-pole Type CHP-GFI breakers are
designed for use in 2-wire, 120V AC
circuits. Figure 12 shows a typical
wiring configuration.
The figure is shown with a 120/240V AC,
single-phase, 3-wire power source, but
a 120/208V AC, 3-phase, 4-wire power
supply is also applicable. Electrical
operation of the Type CHPGFI is not
affected by the equipment ground.
1 per Individual Carton
10,000 AIC
Catalog Number
15
20
30
#14 – 6
#14 – 6
#14 – 6
CHP115GF
CHP120GF
CHP130GF
Figure 12. Typical 1-Pole Wiring Diagram
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Special Application Plug-On Circuit Breakers
TYPE
CH CIRCUIT
BREAKERS
Page 11
CHP Neutral Switching Breakers
10,000 Amperes Interrupting Capacity
120 or 120/240V AC
Type CHP Neutral Switching Breakers, 3/4-inch (19.1 mm)
per Pole 120 or 120/240V AC, 10,000 AIC
Used to open the neutral along power line(s) for applications of gas pumps.
Ampere
Rating
15
20
1
Wire
Size
Range
Cu/Al
60ºC or
75°C
AWG
#14 – 8
2-Pole
120V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
(Hot leg)
Neutral Out
Neutral In
3-Pole
120/240V AC
Common Trip
Requires Three 3/4-inch
(19.1 mm) Spaces
1 per Shelf Carton
1 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CHP215SW 1
CHP220SW 1
CHP315SW 1
CHP320SW 1
Phase
Phase
Neutral Out
Neutral In
For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space.
CH-M50 High Ambient Breaker
Type CH-M50 High Ambient Breakers
3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Ampere
Rating
15
20
25
30
35
40
45
50
60
70
Wire
Size
Range
Cu/Al
60ºC or
75°C
AWG
(1) #14 – 8
(2) #14 – 10
1-Pole
120/240V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
120/240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
10 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
CH115M50
CH120M50
CH125M50
CH130M50
CH135M50
CH140M50
CH145M50
CH150M50
—
—
CH215M50
CH220M50
CH225M50
CH230M50
CH235M50
CH240M50
CH245M50
CH250M50
CH260M50
CH270M50
CH-HM and CHP-HM High Magnetic Breakers
Type CH-HM and CHP-HM High Magnetic Breakers
3/4-inch (19.1 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Ampere
Rating
Wire
Size
Range
Cu/Al
60ºC or
75°C
AWG
1-Pole
120/240V AC
Requires One 3/4-inch
(19.1 mm) Space
2-Pole
120/240V AC
Common Trip
Requires Two 3/4-inch
(19.1 mm) Spaces
10 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog Number
Catalog Number
15
20
(1) #14 – 8
(2) #14 – 10
CH115HM
CH120HM
CH215HM
CH220HM
15
20
(1) #14 – 8
(2) #14 – 10
CHP115HM
CHP120HM
CHP215HM
CHP220HM
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH CIRCUIT
BREAKERS
Accessories
Page 12
Circuit Breaker Accessories
Description
Ordering
Quantity 1
Handle Ties 2
Handle tie bar for physically joining the handles of two adjacent 1-pole
Type CH Circuit Breakers. (Molded Plastic Handle Cover)
Handle Lockoffs 34
Padlockable device for locking the handle of 1-, 2-, or 3-pole
Type CH Circuit Breakers (Escutcheon Mounted) 5
Padlockable device for locking the handle of a 1-, 2- or 3-pole
Type CHGFI Circuit Breaker. (Escutcheon Mounted) 5
Catalog
Number
CHHT
25
CHHT
1
CHPL
1
CHPLGF
CHPL
46
Handle Lockdogs
Device used to secure handle in “On” or “Off” position for
1-pole Type CH Circuit Breakers. (Handle Mounted) 7
10
CHLO
Hold-Down Kits 8
Hold-down retainer kit for 1-, 2-, 3-pole Type CH Circuit Breakers. For
6 – 24 circuit 125 ampere single- and 3-phase, 12 – 42 circuit singlephase 225 ampere and 24 – 42 circuit 3-phase 225 ampere MLO
Type CH Loadcenters.
1
CH125RB
Hold-Down Kits 8
Hold-down retainer kit for 1-, 2-, 3-pole Type CH Circuit Breakers
for 2 through 4 circuit MLO CH Loadcenters.
1
CH125RB24
Mechanical Interlock
Type CH for 2-, 3- and 4-pole Breakers
Shunt Trip for CH
120V AC
CHPLGF
10
CHML
1
ST 9
CHLO
CH125RB
Main and Sub-Feed Lug Blocks
Number
of Poles
Ampere
Rating
Number of
3/4-inch (19.1 mm)
Spaces Needed
Wire Size Range
Cu/Al 60ºC or 75ºC
AWG
2
3
125
125
2
3
#1/0
#1/0
1
2
3
4
5
6
7
8
9
Ordering
Quantity
Catalog
Number
CHML
1
1
CHSF2125
CHSF3125
Must be purchased in multiples of ordering quantities indicated.
Handle Ties: Typically used to join two similar independent single-pole breakers to form a 2-pole
noncommon trip breaker.
Handle Lockoffs: Devices that use a padlock to lock the circuit breaker’s handle in the “On” or
“Off” position.
Requires one additional pole space.
Escutcheon Mounted: Device mounted semipermanently to the face of the circuit breaker and
secured by the loadcenter deadfront.
Handle Lockdogs: Devices that are used to secure a circuit breaker’s handle in the “On” or “Off”
position. Handle Lockdogs are not padlockable devices.
Handle Mounted: Device mounted above or below handle using spring pressure.
Hold-Down Kits: Devices used to secure the circuit breaker to the loadcenter for back-feed main
application. See NEC Article 384-16(g).
Add suffix indicated to end of breaker catalog number.
CHSF2125
CHSF3125
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Single-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
TYPE
CH ASSEMBLIES
Page 13
70 2
AMP
SPACES
2
SINGLE POLES
DIAGRAM 1
1.500
(38.10)
0.500
(12.70)
0.200 ± 0.005 Diameter
(5.08 ± 0.13)
1.410
(35.81)
3.850
(97.79)
2.190
(55.63)
1.680
(42.67)
0.200 ± 0.005 Diameter
(5.08 ± 0.13)
0.685
(17.40)
3.087
(78.41)
.188
(4.78)
0.750
(19.05)
3.805
(96.65) Maximum
#8 - #2 AWG (Al/Cu)
Handle
Height
0.937
(23.80)
CH9MB270
125 2
AMP
SPACES
2
SINGLE POLES
DIAGRAM 2
.297
(7.54)
#10 Mounting
Screws
.156
(3.96)
.625
(15.88)
4.588
2.844 2.250
(116.54) (72.24) (57.15)
.156 Diameter Nib
1.812
(46.02)
2.000
(50.80)
3.563
(90.50)
.031 x 45° Chamfer
1 Nib Required
.598
(15.19)
.188
(4.78)
3.000
(76.2)
3.700
(93.98) Maximum
1.063
(26.99)
2.688
(68.28)
Wire Range:
(1) 2/0 - 14 AWG (Al/Cu)
Handle
Height
.183
(4.65)
1.782
(45.26)
CH2L125INT
Legend
Dimensions – Inches (mm)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
Page 14
125 4
AMP
SPACES
4
SINGLE POLES
DIAGRAM 3
125 8
AMP
2.041
(51.84)
1.625
(41.28)
.031 x 45° Chamfer
1 Nib Required
3.125
(79.38)
.183
(4.65)
SINGLE POLES
1.439
(36.55)
Wire Range:
(1) 4/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.961
(100.61)
3.311
(84.10)
Maximum
Handle
Height
4.666
(118.52)
3.324
(84.43)
Maximum
Handle
Height
1.52
(38.61)
.188 (4.78)
.188
(4.78)
Wire Range:
(1) 2/0 - 14 AWG (Al/Cu)
6.332
(160.83)
2.000
(50.80)
6.00 (152.40)
.169 Diameter
(4.29)
2.688
(67.28)
5.56
(141.22)
.203 Diameter
(5.16)
3.125
(79.38)
.250
(6.35)
#10 Mounting
Screws
1.182
(30.02)
3.563
(90.50)
8
DIAGRAM 4
.156 Diameter Nib
.781
(19.84)
SPACES
2.172
(55.17)
CL
breaker
2.250
(57.15)
1.063
(26.99)
2.844
(72.24)
.750
(19.05)
5.00
(127.00)
.780
(19.81)
.203 Diameter
(5.16)
3.125
(79.38)
.780
(19.81)
.169 Diameter
(4.29)
CH8L125INT
CH4L125INT
Legend
Dimensions – Inches (mm)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
TYPE
CH ASSEMBLIES
Page 15
125 12
AMP
SPACES
12
SINGLE POLES
DIAGRAM 5
AMP
1.439
(36.55)
Wire Range:
2/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.961
(100.61)
3.256
(82.70)
1.610
(40.90)
Maximum
Handle
Height
1.439
(36.55)
SINGLE POLES
Wire Range:
2/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.324
(84.43)
.188 (4.78)
1.610
(40.90)
.188 (4.78)
6.249 (158.72)
3.125
(79.38)
6.249 (158.72)
.218 Diameter
(5.54)
.310
(7.87)
2.172
(55.17)
3.125
(79.38)
.218 Diameter
(5.54)
2.172
(55.17)
CL
breaker
7.750
(196.85)
16
3.961
(100.61)
3.324
(84.43)
.310
(7.87)
SPACES
DIAGRAM 6
3.125
(79.38)
Maximum
Handle
Height
125 16
CL
breaker
.750
(19.05)
.750
(19.05)
9.250
(234.95)
7.000
(177.80)
8.400
(213.36)
.218 (5.54)
.218 (5.54)
CH12L125INT
CH16L125INT
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
Page 16
200 12
AMP
SPACES
12
SINGLE POLES
DIAGRAM 7
AMP
1.451
(36.86)
3.124
(79.35)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
16
SINGLE POLES
1.451
(36.86)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
3.324
(84.43)
2.010
(51.05)
Maximum
Handle
Height
3.324
(84.43)
.188 (4.78)
2.010
(51.05)
.188 (4.78)
6.249 (158.72)
.310
(7.87)
SPACES
DIAGRAM 8
3.124
(79.35)
Maximum
Handle
Height
200 16
3.125
(79.38)
6.249 (158.72)
.218 Diameter
(5.54)
.310
(7.87)
2.797
(71.04)
3.125
(79.38)
.218 Diameter
(5.54)
2.797
(71.04)
CL
breaker
CL
breaker
.750
(19.05)
.750
(19.05)
13.625
(346.08)
13.625
(346.08)
12.875
(327.03)
12.875
(327.03)
.218 (5.54)
.218 (5.54)
CH12L200INT
CH16L200INT
Legend
Dimensions – Inches (mm)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
TYPE
CH ASSEMBLIES
Page 17
225 24
AMP
SPACES
24
SINGLE POLES
DIAGRAM 9
AMP
1.451
(36.86)
3.124
(79.35)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
32
SINGLE POLES
1.451
(36.86)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
3.961
(100.61)
3.324
(84.43)
2.010
(51.05)
Maximum
Handle
Height
3.324
(84.43)
2.010
(51.05)
.188 (4.78)
.188 (4.78)
6.249 (158.72)
6.249 (158.72)
.310
(7.87)
SPACES
DIAGRAM 10
3.124
(79.35)
Maximum
Handle
Height
225 32
3.125
(79.38)
.218 Diameter
(5.54)
.310
(7.87)
3.125
(79.38)
.218 Diameter
(5.54)
2.797
(71.04)
2.797
(71.04)
CL
breaker
CL
breaker
.750
(19.05)
.750
(19.05)
13.625
(346.08)
12.875
(327.03)
15.875
(403.23)
15.025
(381.64)
.218 (5.54)
CH24L225INT
.218 (5.54)
CH32L225INT
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
Page 18
225 42
AMP
SPACES
42
SINGLE POLES
DIAGRAM 11
3.125
(79.38)
1.451
(36.86)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
Maximum
Handle
Height
3.324
(84.43)
2.010
(51.05)
.188 (4.78)
6.249 (158.72)
.310
(7.87)
3.125
(79.38)
.218 Diameter
(5.54)
2.797
(71.04)
CL
breaker
.750
(19.05)
19.625
(498.48)
18.875
(479.43)
.218 (5.54)
CH42L225INT
Legend
Dimensions – Inches (mm)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
TYPE
CH ASSEMBLIES
Page 19
125 12
AMP
SPACES
12
SINGLE POLES
DIAGRAM 12
AMP
1.440
(36.58)
1.440
(36.58)
1.685
(42.80)
Wire Range:
2/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.324
(84.43)
1.610
(40.90)
Maximum
Handle
Height
1.440
(36.58)
1.440
(36.58)
SINGLE POLES
Wire Range:
2/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.324
(84.43)
1.610
(40.90)
.188 (4.78)
.188 (4.78)
6.249 (158.72)
6.249 (158.72)
3.125
(79.38)
.218 Diameter
(5.54)
.310
(7.87)
3.125
(79.38)
.218 Diameter
(5.54)
2.172
(55.17)
2.172
(55.17)
CL
breaker
CL
breaker
7.750
(196.85)
18
3.961
(100.61)
3.961
(100.61)
.310
(7.87)
SPACES
DIAGRAM 13
1.685
(42.80)
Maximum
Handle
Height
125 18
.750
(19.05)
.750
(19.05)
7.000
(177.80)
10.750
(273.05)
.218 (5.54)
10.000
(254.00)
CH12L3125INT
.218 (5.54)
CH18L3125INT
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
CH ASSEMBLIES
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
Page 20
125 24
AMP
SPACES
24
SINGLE POLES
DIAGRAM 14
AMP
1.440
(36.58)
1.440
(36.58)
Wire Range:
2/0 - #6 AWG (Al/Cu)
Torque Wire Screws*
3.961
(100.61)
24
SINGLE POLES
1.674
(42.52)
1.451
(36.86)
1.451
(36.86)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
3.324
(84.43)
1.610
(40.90)
Maximum
Handle
Height
3.324
(84.43)
.188 (4.78)
2.010
(51.05)
.188 (4.78)
6.249 (158.72)
.310
(7.87)
SPACES
DIAGRAM 15
1.685
(42.80)
Maximum
Handle
Height
225 24
3.125
(79.38)
6.249 (158.72)
.218 Diameter
(5.54)
.310
(7.87)
2.172
(55.17)
3.125
(79.38)
.218 Diameter
(5.54)
2.797
(71.04)
CL
breaker
CL
breaker
.750
(19.05)
.750
(19.05)
12.250
(311.15)
13.625
(346.08)
11.500
(292.10)
12.875
(327.03)
.218 (5.54)
.218 (5.54)
CH24L3125INT
CH24L3225INT
Legend
Dimensions – Inches (mm)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
TYPE
CH ASSEMBLIES
Page 21
225 30
AMP
SPACES
30
SINGLE POLES
DIAGRAM 16
AMP
1.438
(36.53)
1.438
(36.53)
1.674
(42.52)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
42
SINGLE POLES
1.451
(36.86)
1.451
(36.86)
Wire Range:
(1) 300 kcmil - #4 AWG (Al/Cu)
Torque Wire Screws: 225 lb-in
3.961
(100.61)
3.961
(100.61)
Maximum
Handle
Height
3.324
(84.43)
3.324
(84.43)
2.010
(51.05)
2.010
(51.05)
.188 (4.78)
.188 (4.78)
6.249 (158.72)
6.249 (158.72)
.310
(7.87)
SPACES
DIAGRAM 17
1.687
(42.85)
Maximum
Handle
Height
225 42
3.125
(79.38)
.218 Diameter
(5.54)
.310
(7.87)
3.125
(79.38)
.218 Diameter
(5.54)
2.797
(71.04)
2.797
(71.04)
CL
of breaker
CL
breaker
.750
(19.05)
.750
(19.05)
15.875
(403.23)
15.025
(381.64)
19.625
(498.48)
.218 (5.54)
18.875
(479.43)
CH30L3225INT
.218 (5.54)
CH42L3225INT
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
OEM Loadcenter Interior Assemblies
Page 22
Type BR Loadcenter Interior Assemblies
Ampere
Rating
Maximum Number
1-Inch (24.5 mm)
Spaces
UL
File
Single Poles Reference
Main Terminal Wire Size Range
(Per Phase)
Cu/Al 60°C or 75°C
Standard
Package
Quantity
Catalog
Number
Diagram Reference
Number
Page
Single-Phase Single-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
70
2
4
E8741
(1) #8–#2 AWG Cu/Al
20
24INT70B
18
32
125
2
4
E8741
(1) 1/0–#14 AWG Cu
2/0–12 AWG Al
20
24INT125B
19
32
125
6
12
E52977
(1) 2/0–#14 AWG Cu/Al
20
612INT125SRB
20
33
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
125
4
8
E8741
(1) 2/0–#14 AWG Cu/Al
20
48INT125B
21
34
125
6
12
E8741
(1) 2/0–#14 AWG Cu/Al
20
612INT125B
22
34
125
8
16
E8741
(1) 2/0–#14 AWG Cu/Al
20
816INT125B
23
35
125
12
12
E52977
(1) 2/0–#14 AWG Cu/Al
20
1212INT125B
24
35
125
12
24
E52977
(1) 2/0–#14 AWG Cu/Al
20
1224INT125B
25
36
125
16
24
E52977
(1) 2/0–#14 AWG Cu/Al
20
1624INT125B
26
36
125
20
24
E52977
(1) 2/0–#14 AWG Cu/Al
10
2024INT125B
27
37
125
24
24
E52977
(1) 2/0–#14 AWG Cu/Al
10
2424INT125B
28
37
200
8
16
E52977
(1) 300 kcmil –#1 AWG Cu/Al
20
816INT200B
29
38
200
12
24
E52977
(1) 300 kcmil –#1 AWG Cu/Al
20
1224INT200B
30
38
200
30
40
E52977
(1) 300 kcmil –#1 AWG Cu/Al
10
3040INT200B
31
39
225
42
42
E52977
(1) 300 kcmil –#1 AWG Cu/Al
10
4242INT225B
32
39
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
125
8
16
E52977
(1) 2/0–#14 AWG Cu/Al
20
816INT125BC
33
40
125
12
12
E52977
(1) 2/0–#14 AWG Cu/Al
20
1212INT125BC
34
40
200
12
24
E52977
(1) 300 kcmil –#1 AWG Cu/Al
20
1224INT200BC
35
41
Three-Phase Double-Row Breaker Mounting – Aluminum Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
125
12
24
E52977
(1) 2/0–#8 AWG Cu/Al
10
1224INT3125B
36
42
150
18
36
E52977
(1) 300 kcmil–#2 AWG Cu/Al
10
1836INT3150B
37
42
150
24
42
E52977
(1) 300 kcmil–#2 AWG Cu/Al
10
2442INT3150B
38
43
200
30
42
E52977
(1) 300 kcmil–#2 AWG Cu/Al
10
3042INT3200B
39
43
225
42
42
E52977
(1) 300 kcmil–#2 AWG Cu/Al
10
4242INT3225B
40
44
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
125
12
24
E52977
(1) 2/0–#8 AWG Cu/Al
10
1224INT3125BC
41
45
200
12
24
E52977
(1) 300 kcmil–#2 AWG Cu/Al
10
1224INT3200BC
42
45
Catalog Numbering System
12 24 INT 3 125 B
Maximum Spaces
Maximum Single Poles
Interior
Bulk Pack / C Indicates Copper Bus
Ampere Rating
Single-Phase: Blank / Three-Phase: 3
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
Loadcenter Accessories
BR ASSEMBLIES
Page 23
Neutral Assemblies
Ampere
Rating
UL
File
Reference
Main Incoming Terminal
Wire Size Range
60°C or 75°C
Number of Terminals
125
E52977
#6–1/0 AWG Cu
#6–2/0 AWG Al
10
–
20
10NEU125B
13
5.938 (150.83)
5.400 (137.16)
125
E52977
#6–1/0 AWG Cu
#6–2/0 AWG Al
17
–
20
17NEU125B
13
8.388 (213.06)
7.850 (199.40)
125
E52977
#6–1/0 AWG Cu
#6–2/0 AWG Al
20
–
20
20NEU125B
13
9.438 (239.73)
8.900 (226.06)
#14–4 AWG
Cu/Al
#6–1/0 AWG Cu
#6–2/0 AWG Al
Standard Catalog
Package
Number
Quantity
Dimensions – Inches (mm)
Figure Overall Length
A
Mounting
B
225
E52977
#1–300 kcmil Cu/Al
24
1
20
24NEU225B
14
10.913 (277.19) 10.300 (261.62)
225
E52977
#1–300 kcmil Cu/Al
35
1
20
35NEU225B
14
15.813 (401.65) 15.200 (386.08)
125
—
—
4
2
1
BINA
15
2.266 (57.56)
Figure 13
0.594 (15.09)
Figure 14
A
.269
(6.83)
A
.344
(8.74)
B
.844
(21.44)
.269
(6.83)
B
.844
(21.44)
1.750
(44.45)
CL of Mounting Hole
CL of Mounting Hole
2.360
(59.94)
2.860
(72.64)
2.360
(59.94)
Figure 15
.120
(3.05)
A
.250
(6.35)
CL of Mounting Hole
1.182
(30.02)
.750
(19.05)
.688
(17.47)
CL
of
Mounting
Hole
.182 Diameter
(4.62)
.156
(3.96)
1.750
(44.45)
1.187
(30.15)
B
.344
(8.74)
2.000
(50.80)
Add-on Lugs for Neutral Assemblies
Description
Wire Size Range
Cu/Al 60°C or 75°C
Ordering
Quantity 1
Neutral/Ground Lug
Add-On Neutral or Ground Lug
#2/0 Maximum
1
#3/0 Maximum
1
300 kcmil Maximum 1
NL20
NL30
NL300
Length
Inches (mm)
Ordering
Quantity 1
Catalog
Number
2.54 (64.5)
3.59 (91.2)
4.29 (109.0)
5.34 (135.6)
4.61 (117.1)
5.69 (144.5)
6.74 (171.2)
8.14 (206.8)
9.19 (233.4)
5.78 (146.8)
1
1
1
1
1
1
1
1
1
1
GBK5 2
GBK520 2
GBK10 2
GBK1020 2
GBK13 2
GBK14 2
GBK1420 2
GBK21 2
GBK2120 2
BRGBK39512 34
Catalog
Number
GBK14
Ground Bar Kits
f
d
f
f
f
k
f
d
f
k
f
f
f
dssssds
dssssdsj
dssssdssssss
dssssdssssssj
dssssdssssssssss
dssssdssssssssssj
dssssdsssssssssssssssss
dssssdsssssssssssssssssj
ofodofooofodofooofo
1
2
3
4
Must be purchased in multiples of ordering quantities indicated.
Distance between mounting holes is 1-3/4 inches (44.5 mm).
For 1- and 3-phase 400 and 600 ampere applications.
Distance between mounting holes is 2-11/32 inches (59.5 mm).
BRGBK39512
Ground Bar Legend
s (3) #14 – #10 Cu/Al or (1) #14 – #4 Cu/Al
j (1) #6 – 2/0 Cu/Al
o (1) #14 – #6 Cu/Al or (2) #14 – #12 Cu/Al
(1) 1/0 – 14 or (3) #10 – 12 Cu/Al
(1) #14 – 1/0 Cu/Al or (3) #14 – #10 Cu/Al
f (1) #6 – 14 Cu/Al or (2) #1/0 – 14 Cu/Al
d Mounting Hole
fk
Description
(See Legend)
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR CIRCUIT
BREAKERS
Page 24
BR Circuit Breakers
Cutler-Hammer Type BR plug-on
breakers in the standard 1-inch
(25.4 mm) per pole package have
unique color-coded cases that indicate
UL listed 10 kA or 22 kA interrupting
ratings and can be used as main or
branch disconnect devices. All are type
I.C. (interchangeable) devices; several
ratings are SWD and HACR approved.
Typical ampacity range for BR
breakers is 15 to 150 amperes.
GFCB® People Protection Breakers
Cutler-Hammer Type GFCBs (ground
fault circuit breakers) combine state-ofthe-art electronic technology with a
circuit breaker mechanism in a
compact 1-inch (25.4 mm) per pole
package. The GFCB automatically
senses hot wire-to-ground faults in a
4 to 6 mA range and disconnects the
power, thus providing an extra margin
of safety beyond that of conventional
circuit breakers. GFCB applications
include bathrooms, cellar outlets,
swimming pools, outdoor branch
circuits and kitchen branch circuits.
Available in UL listed 120 and 120/240V
ratings. Cutler-Hammer also offers
non-UL listed GFCBs for international
applications as well as ground fault
devices for equipment protection.
GFEP Equipment Protection
Breakers
The Cutler-Hammer Type GFEP device is
similar to the GFCB, except that it is
designed to protect equipment (not
people) against damage from arcing
ground faults. It is available with a 30 mA
trip level. Applications include infrared
heating equipment, computer equipment, process control equipment, etc.
BJ Circuit Breakers
Available in 125 through 200 ampere
frames, Cutler-Hammer Type BJ plugon breakers have 10 kA and 22 kA
interrupting ratings that can be used
as main or branch disconnect devices.
Large extruded aluminum box lugs,
complies with UL486B, provide cool
operation. Tripping mechanism has
thermal and magnetic protection for
long-life performance. Rupture gas is
safely vented into box gutter.
BD Circuit Breakers
BD plug-on breakers have the same
construction as Cutler-Hammer Type BR
1-inch (25.4 mm) per pole devices
except that two poles are in a spacesaving 1-inch (25.4 mm) package.
UL listed interrupting rating is 10 kA.
Some ratings are SWD and HACR
approved. Exclusive CTL rejection
feature allows only 42 circuits in the
panel in compliance with NEC Article
384-15.
BQ Circuit Breakers
Quadplex® construction of CutlerHammer Type BQ plug-on breakers
incorporates two duplex breakers
assembled together to provide various
combinations of 2-pole and single-pole
devices in a 2-inch (50.8 mm) package,
and allows compliance with NEC Article
240-20(b). The 2-pole combinations of
Cutler-Hammer Type BQ breakers are
marked “independent trip” meaning
that each pole of a 2-pole device trips
independently of the other, but may be
actuated jointly by means of the handle
tie. Independent trip devices may only
be used on 3-wire Edison circuits where
the neutral is present.
BQC Circuit Breakers
Quadplex construction of CutlerHammer Type BQC plug-on breakers
incorporates a special internal
common trip cam. BQC breakers are
available in several combinations of
2-pole and single-pole devices
wherein the 2-pole circuits have an
internal common trip mechanism.
These breakers are labeled “common
trip” and meet all the requirements of
UL489 paragraph 9.1 requiring
multipole breakers to have common
trip. Common trip breakers are
required on all 240V circuits where
there is no neutral present such as
water heaters, baseboard heat, air
conditioners and other motorloads.
Heavy-duty mechanism
spring for reliable
operation.
Provision for
handle tie.
Special Application Breakers
As the name implies, these devices are
designed for special applications as
required by the National Electrical Code®.
Water Heater Breaker
Some watthour meters incorporate
rate register switches used in conjunction with off-peak rates. Water heater
breakers do not derive their circuit
from the loadcenter stab. The line and
load side of the breaker are fed to
terminals on the breaker. Except for
these terminations, the device offers
normal circuit breaker protection.
Switching Neutral Breaker
Primary application for the CutlerHammer switching neutral breaker is
for protection of process equipment
such as gas pumps that utilize flammable liquids. Non-automatic pole
breaks the neutral power leg, minimizing the danger of arc conditions.
2-Pole Breakers 120V or More-to-Ground
Used on Delta distribution systems,
these Type BR breakers are applied on
phase legs where voltage-to-ground is
above 120V.
Non-Automatic Molded Case Switch
Identical to comparable circuit breaker
frames with this exception: nonautomatic molded case switches do not
have thermal or magnetic elements.
Arc Fault Circuit Interrupters (AFCIs)
Reduce the risk of fire by detecting
and interrupting electrical arcing faults
which standard thermal magnetic
breakers cannot. For more information, see page 27.
Black Molded Handle.
Hardened cradle for
positive action under
fault conditions.
Four-rivet construction
enhances strength and
structural integrity of
breaker case.
Non-abrasive integrally
molded pivot for quick
mechanism response.
Common trip cam
assures simultaneous
pole opening.
Heavy-duty multi-strand
flexible copper shunt for
cool operation.
One-piece moving
contact arm for quick
on/off response.
Heavy-duty line terminal
and spring clip for quick
load center installation
and cool operation.
Silver tungsten alloy
contacts.
One-piece frame
assembly for
dimensional stability
and reliable operation.
UL 486B approved terminal
assembly for use with
copper or aluminum wire.
Callibrated onepiece bimetal for
reliable thermal
trip function.
Unique one-piece heavy-duty De-ion
assembly for quick arc interruption.
Full width slot for
channel type lead
center hold-downs.
One-piece molded
case construction.
BR Breaker Section View
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Large gas port for venting
short circuit gases safely
into load center gutter.
Plug-On Circuit Breakers
TYPE
BR CIRCUIT
BREAKERS
Page 25
Plug-On Circuit Breakers, Types BR
10,000/22,000/42,000 Amperes
Interrupting Capacity 120, 120/240 or 240V AC
BR120
BR215
BR320
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120, 120/240 or 240V AC, 10,000, 22,000 or 42,000 AIC
Note: All Type BR 1-, 2-, and 3-pole circuit breakers carry listing for HACR application.
For circuit breakers with a shunt trip, add ST suffix.
Ampere
Rating
Wire Size
Range
Cu/Al
60°C or
75°C
AWG
1-Pole 120/240V AC
Requires One 1-Inch (25.4 mm)
Space
2-Pole 120/240V AC
Common Trip
Requires Two 1-Inch (25.4 mm) Spaces
3-Pole 240V AC
Common Trip
Requires Three 1-Inch (25.4 mm)
Spaces
10 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
10,000 AIC
22,000 AIC
10,000 AIC
22,000 AIC
42,000 AIC
10,000 AIC
22,000 AIC
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
10
15
20
25
30
#14 – 4
BR110
BR115 12
BR120 12
BR125
BR130
—
BRH115
BRH120
BRH125
BRH130
BR210
BR215 3
BR220 3
BR225 3
BR230 3
—
BRH215
BRH220
BRH225
BRH230
—
—
—
—
—
BR310
BR315 12
BR320 12
BR325
BR330
—
BRH315 12
BRH320 12
BRH325
BRH330
35
40
45
50
#14 – 4
BR135
BR140
—
BR150
BRH135
BRH140
BRH145
BRH150
BR235 3
BR240 3
BR245 3
BR250 3
BRH235
BRH240 3
BRH245
BRH250 3
—
—
—
—
BR335
BR340
BR345
BR350
BRH335
BRH340
BRH345
BRH350
55
#14 – 3
BR150
BRH155
BR255
BRH255
—
BR355
BRH355
60
70
80
90
100
110
#4 – 1/0
BR160
BR170
—
—
—
—
BRH160
BRH170
—
—
—
—
BR260
BR270
BR280
BR290
BR2100
BR2110
BRH260
BRH270
BRH280
BRH290
BRH2100
BRH2110
BRHH260
BRHH270
BRHH280
BRHH290
BRHH2100
BRHH2110
BR360
BR370
BR380
BR390
BR3100
—
BRH360
BRH370
BRH380
BRH390
BRH3100
—
125
150
#4 – 2/0
—
—
—
—
BR2125
BR2150 4
BRH2125
—
BRHH2125
—
—
—
—
—
1
2
3
4
1-pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads.
Add-suffix H to catalog number.
Switching duty rated.
On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.
For use as a branch circuit breaker in 400 and 600 ampere panels only.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR CIRCUIT
BREAKERS
Special Application Plug-On Circuit Breakers
Page 26
Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP
10,000/22,000 Amperes Interrupting Capacity
120 or 120/240V AC
Type GFCB Ground Fault Circuit Breakers (5 Milliampere)
1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC, 22,000 AIC
Ampere
Rating
Wire Size Range
Cu/Al 60°C or 75°C
AWG
1-Pole
120V AC
Requires One
1-Inch
(25.4 mm)
Space
2-Pole
120/240V AC
Common Trip
Requires Two
1-Inch
(25.4 mm)
Spaces
1 per Shelf Carton
10,000 AIC
Type GFCB 1-Pole
1 per Shelf Carton
22,000 AIC
15
20
25
30
40
50
1
2
Type GFCB 2-Pole
Ground Fault Application Notes
Single-pole GFCBs are designed
for use in 2-wire, 120V AC circuits.
Figure 16 shows a typical wiring
configuration.
Two-pole GFCBs are designed for
use in 3-wire, 120/240V AC circuits,
120V AC multiwire circuits employing
common, neutral and 2-wire, 240V AC
circuits obtained from a 120/240V AC
source.
Figures 17 and 18 illustrate typical wiring configurations for 120/240V AC
multiwire circuits.
#14 – 4
GFCB115
GFCB120
GFCB125
GFCB130
GFCB140
—
10,000 AIC
GFCBH115
GFCBH120
GFCBH125
—
—
—
GFCB215
GFCB220
GFCB225
GFCB230
GFCB240 2
GFCB250 2
GFCBH215
GFCBH220
GFCBH225
GFCBH230
—
—
Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page 31.
For use with copper wire only.
Type GFEP Ground Fault Equipment Protectors (30 Milliampere)
1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Ampere
Rating
Wire Size Range
1-Pole
Cu/Al 60°C or 75°C 120V AC
AWG
Requires One
1-Inch Space
2-Pole
120/240V AC
Common Trip
Requires Two
1-Inch Spaces
1 per Shelf Carton
15
20
25
30
40
50
#14 – 4
1 per Shelf Carton
10,000 AIC
10,000 AIC
Catalog
Number
Catalog
Number
GFEP115
GFEP120
GFEP125
GFEP130
—
—
GFEP215
GFEP220
GFEP225
GFEP230
GFEP240
GFEP250
Figure 19 depicts a 240V AC, 2-wire
circuit. Note the “panel neutral”
conductor connects to the neutral
bar, even though the neutral is not
included in the load circuit. This
connection is necessary to supply a
120V AC power source to the ground
fault sensing circuit.
The figures are shown with a
120/240V AC, single-phase, 3-wire
power source, but are also applicable
to a 120/208V AC, 3-phase, 4-wire
power supply. For all figures, the
electrical operation of the GFCB is not
affected by the equipment ground.
22,000 AIC
Catalog
Number
Catalog
Number 1
Figure 16. 1-Pole
Figure 18. 2-Pole
Figure 17. 2-Pole
Figure 19. 2-Pole
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
Special Application Plug-On Circuit Breakers
BR CIRCUIT
BREAKERS
Page 27
Plug-On Arc Fault Circuit
Breakers, Type BR
10,000 Amperes
Interrupting Capacity
120 or 120/240V AC
Type BR FIRE-GUARD™ AFCI Circuit Breakers
1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC
Poles
Ampere
Rating
Configuration
Catalog
Number
Wire Size Range Cu/Al
60ºC or 75ºC AWG
1-Pole
10 kAIC
15
AFCI
AFCI with GFCI
BR115AF
BR115AFGF
#14 – 4
20
AFCI
AFCI with GFCI
BR120AF
BR120AFGF
#14 – 4
15
AFCI Common Trip
AFCI Independent Trip
AFCI Common Trip with GFCI
BR215AF
BR215AFIT
BR215AFGF
#14 – 4
20
AFCI Common Trip
AFCI Independent Trip
AFCI Common Trip with GFCI
BR220AF
BR220AFIT
BR220AFGF
#14 – 4
2-Pole
10 kAIC 12
1
Type BR 1- and 2-Pole
AFCI Circuit Breakers
2
Common trip refers to 2-pole 240V load application sourced by 120/240V AC (see Figure 22).
Independent trip refers to 2-pole shared neutral circuits (see Figure 21 and Figure 23).
120/240V AC
Source
N A B
120/240V AC
Source
N A B
Line B
Line B
2 Pole
1 Pole
Line A
Neutral
120V
Duplex
Receptacle
Neutral
Neutral
Equipment Ground
Equipment Ground
Figure 20. 1-Pole, Single 120V Load
Application Sourced by 120/240V AC
120/240V AC
Source
N A B
240V
Duplex
Receptacle
Figure 22. 2-Pole 240V Load Application
Sourced by 120/240V AC
120/240V AC
Source
N A B
Line B
Line B
Line A
2 Pole
Neutral
Neutral
2 Pole
2-120V
Duplex
Receptacles
Neutral
Neutral
120V Duplex
Receptacle
(With Line Side
Jumper Removed)
Equipment Ground
Line A
Equipment Ground
Figure 21. 1-Pole Shared Neutral with
Multi-Duplex Receptacle Application
Figure 23. 2-Pole Shared Neutral with Duplex
Receptacle Application
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR CIRCUIT
BREAKERS
Page 28
CTL Plug-On Circuit Breakers, Type BD Duplex, BQ and BQC Quadplex
10,000 Amperes Interrupting Capacity 120/240V AC
BQC230230
BQC2302115
Common Trip Quadplex Breakers
Class CTL, 1-Inch (25.4 mm) per Pole 120/240V AC, 10,000 AIC — All circuit breakers have rejection tab feature.
Type BQC Quadplex Common Trip Center Poles
(UL Type BRD)
2-Pole 1
and 1-Pole 2
Wire
Size
Range
Cu/Al
65°C or
75°C
AWG
120V AC
120/240V AC
120V AC
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton
120V AC
Catalog
Number
120/240V AC
Requires Two 1-Inch (25.4 mm) Spaces
120/240V AC
Catalog
Number
Ampere Rating
Outer Left
1-Pole
Center 2-Poles
Common Trip
Outer Right
1-Pole
15
15
15
15
15
—
—
—
20
25
30
40
50
—
—
—
15
15
15
15
15
—
—
—
BQC2202115
BQC2252115
BQC2302115
BQC2402115
BQC2502115
—
—
—
20
20
20
20
20
20
15
20
25
30
40
50
20
20
20
20
20
20
30
—
—
—
—
50
—
—
—
—
20
—
—
—
—
2
120/240V AC
10,000 AIC
120/240V AC
Ampere Rating
1
2-Pole 1
5 per Shelf Carton
10,000 AIC
120V AC
Type BQC Quadplex Common Trip Center and Outer Poles
(UL Type BRD)
Outer 2-Poles
Common Trip
Center 2-Poles
Common Trip
#14 – 4
15
15
15
20
20
20
20
20
15
20
30
15
20
30
40
50
BQC215215
BQC215220
BQC215230
BQC220215
BQC220220
BQC220230
BQC220240
BQC220250
BQC2152120
BQC2202120
BQC2252120
BQC2302120
BQC2402120
BQC2502120
#14 – 4
25
25
30
30
30
30
—
25
30
15
30
40
50
—
BQC225225
BQC225230
BQC230215
BQC230230
BQC230240
BQC230250
—
BQC2502030
—
—
—
—
#14 – 4
40
40
40
50
50
30
40
50
20
50
BQC240230
BQC240240
BQC240250
BQC250220
BQC250250
All Type BQC Quadplex circuit breakers carry listing for HACR applications.
All 15 and 20 ampere single poles are switching duty rated.
Notched
Bus Stab
CTL Circuit
Limiting
Feature
Type BR or
Type BD Duplex, (CTL),
Type BQ and BQC Quadplex
Unnotched
Bus Stab
Type BD
Duplex
Rejection
Tab
Type BR
Notched
Stab
Non-CTL
Non-Circuit
Limiting
Type BR
Figure 24. CTL and Non-CTL Breakers
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR CIRCUIT
BREAKERS
Page 29
BD2020
BQ230230
BQ2302115
Duplex and Independent Trip Quadplex Breakers
Class CTL, 1-Inch (25.4 mm) per Pole 120 or 120/240V AC, 10,000 AIC — All circuit breakers have rejection tab feature.
Type BD Duplex
(UL Type BRD)
1-Pole 1
120/240V AC
120/240V AC
Wire Size
Range
Cu/Al
65°C or 75°C
AWG
Requires One 1-Inch
(25.4 mm) Space
Type BQ Quadplex Independent Trip
(UL Type BRD)
2-Pole 2
and 1-Pole 1
Type BQ Quadplex Independent Trip
(UL Type BRD)
2-Pole
120/240V AC
120V AC
120/240V AC
120V AC
Requires Two 1-Inch
(25.4 mm) Spaces
120/240V AC
Requires Two 1-Inch
(25.4 mm) Spaces
10 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
Ampere
Rating
10,000 AIC
10,000 AIC
10 – 10
15 – 15
15 – 20
15 – 30
20 – 15
20 – 20
20 – 30
25 – 25
30 – 15
30 – 20
30 – 30
30 – 40
30 – 50
50 – 30
1
2
10,000 AIC
120V AC
120V AC
Catalog
Number
Ampere Rating
BD1010
BD1515
BD1520
BD1530
BD2015
BD2020
BD2030
BD2525
BD3015
BD3020
BD3030
BD3040
BD3050
BD5030
#14 – 4
120/240V AC
120V AC
Outer Left
1-Pole
Center
2-Poles
Independent
Trip
Outer Right
1-Pole
15
20
15
20
15
20
15
20
—
—
—
—
—
—
20
20
30
30
40
40
50
50
—
—
—
—
—
—
15
20
15
20
15
20
15
20
—
—
—
—
—
—
Catalog
Number
BQ2202115
BQ2202120
BQ2302115
BQ2302120
BQ2402115
BQ2402120
BQ2502115
BQ2502120
—
—
—
—
—
—
120/240V AC
Ampere Rating
Outer
2-Poles
Independent
Trip
Center
2-Poles
Independent
Trip
15
20
20
20
20
25
30
30
30
40
40
50
—
—
15
20
30
40
50
25
30
40
50
40
50
50
—
—
All 15 and 20 ampere single poles are switching duty rated.
All Type BD Duplex and BQ Quadplex circuit breakers carry listing for HACR applications.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Catalog
Number
BQ215215
BQ220220
BQ220230
BQ220240
BQ220250
BQ225225
BQ230230
BQ230240
BQ230250
BQ240240
BQ240250
BQ250250
—
—
TYPE
BR CIRCUIT
BREAKERS
Plug-On Circuit Breakers
Special Application Plug-On Circuit Breakers
Page 30
Plug-On Circuit Breakers, Types BJ and BJH
10,000/22,000 Amperes Interrupting Capacity
120/240 or 240V AC
For Use in 1-Phase and 3-Phase Loadcenters
150 Amperes and Above
Type BJ
Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240V AC, 10,000, 22,000 AIC
Note: If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page 31.
Ampere
Rating
2-Pole
120/240V AC
Common Trip
Requires Four 1-Inch (25.4 mm) Spaces 1
Wire Size
Range
Cu/Al
60°C or 75°C
10 per Shelf Carton
125
150
175
200
1
2
3-Pole
240V AC
Common Trip
Requires Six 1-Inch (25.4 mm) Spaces 2
5 per Shelf Carton
10,000 AIC
22,000 AIC
10,000 AIC
22,000 AIC
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
BJ2125
BJ2150
BJ2175
BJ2200
BJH2125
BJH2150
BJH2175
BJH2200
BJ3125
BJ3150
BJ3175
BJ3200
BJH3125
BJH3150
BJH3175
BJH3200
#2 AWG –
300 kcmil
Breaker uses two 1-Inch (25.4 mm) pole spaces on left side and two 1-Inch (25.4 mm) pole spaces on right side of loadcenter.
Breaker uses three 1-Inch (25.4 mm) pole spaces on left side and three 1-Inch (25.4 mm) pole spaces on right side of loadcenter.
Plug-On Special Application Circuit Breakers
10,000 Amperes Interrupting Capacity
120, 120/240 or 240V AC
BRWH215
Water Heater Breaker
BRSN220
Switching Neutral Breaker
Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole, 120, 120/240 or 240V AC
Water Heater Breakers
2-Pole
120/240V AC
Common Trip
Requires Two 1-Inch
(25.4 mm) Spaces
Switching Neutral Breakers
LINE
LOAD
2-Pole
120V AC
Common Trip
Requires Two 1-Inch
(25.4 mm) Spaces
OUT
IN
NEUTRAL
Wire Size
Range
Cu/Al
60°C
or 75°C
AWG
240V Breakers
Non-Automatic
Molded Case Switches
2-Pole
240V AC
Common Trip
Requires Two 1-Inch
(25.4 mm) Spaces
2-Pole
240V AC
Requires Two 1-Inch
(25.4 mm) Spaces
With Isolated Line Terminals
for Separately Metered
Water Heaters
With Switching Neutral
Pole for Gasoline Pump
Applications
Where Voltage to
Ground is 240V AC
For Use as Disconnect
Contains No Magnetic or
Thermal Trip Properties
5 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
5 per Shelf Carton
10,000 AIC
10,000 AIC
10,000 AIC
Ampere
Rating
Catalog
Number
Ampere
Rating
Catalog
Number
Ampere
Rating
15
20
30
—
—
—
—
—
—
—
BRWH215
BRWH220
BRWH230
—
—
—
—
—
—
—
15
20
25
30
—
—
—
—
—
—
BRSN215
BRSN220
BRSN225
BRSN230
—
—
—
—
—
—
#14 – 4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
#4 – 1/0
5,000 AIC
Catalog
Number
Ampere
Rating
Catalog
Number
10
15
20
25
30
35
40
45
50
55
BR210H
BR215H
BR220H
BR225H
BR230H
BR235H
BR240H
BR245H
BR250H
BR255H
—
—
—
—
—
—
—
—
50
—
—
—
—
—
—
—
—
—
BR250NA
—
60
70
80
90
100
BR260H
BR270H
BR280H
BR290H
BR2100H
60
—
—
—
100
BR260NA
—
—
—
BR2100NA
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Accessories
TYPE
BR CIRCUIT
BREAKERS
Page 31
Circuit Breaker Accessories
Ordering Catalog
Quantity Number
Description
1
Handle Ties 2
Handle tie bar for physically joining the handles of two adjacent 1-pole
Type BR Circuit Breakers. (Metal Cylinder Pin Type)
Handle tie bar for joining two independent outside poles of Types BQ and
BQC Quadplex and outside poles of two Type BD Duplex Circuit Breakers.
Handle tie bar for joining two adjacent outside poles of Types BQ and BQC
Quadplex and outside poles of two Type BD Duplex Circuit Breakers.
Handle Lockoffs 3
Padlockable device for locking the handle of 1-, 2-, or 3-pole Type BR
Circuit Breakers and 1-pole of a Type BD Duplex or one independent outside
pole of a Type BQ or BQC Quadplex Circuit Breaker. (Escutcheon Mounted) 4
Padlockable device for locking the handle of a 1-pole Type BR Circuit Breaker.
(Handle Mounted) 5
Padlockable device for locking the handle of a 2- and 3-pole Type BR
Circuit Breaker. (Handle Mounted) 5
Padlockable device for locking the handle of a 1-pole Type BD Duplex,
BQ or BQC Quadplex Circuit Breaker. (Handle Mounted) 5
Padlockable device for locking the handle of the two center poles and the
two outer poles of a 2-pole Type BQ and BQC of Type BQ and BQC
Quadplex Circuit Breakers. (Escutcheon Mounted) 4
Handle Lockdogs 6
Device used to secure handle in “On” or “Off” position for 1-, 2-, or 3-pole Type
BR Circuit Breakers and 1-pole of Type BD Duplex and one independent outside
pole of Type BQ or BQC Quadplex Circuit Breakers. (Escutcheon Mounted) 4
Device used to secure handle in “On” or “Off” position for 1-pole
Type BR Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for 2- and 3-pole
Type BR Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for 1-pole Type GFCB
Ground Fault Circuit Breakers. (Handle Mounted) 5
Device used to secure handle in “On” or “Off” position for one independent
outside pole of Types BQ and BQC Quadplex or 1-pole Type BD Duplex
Circuit Breakers. (Handle Mounted) 5
Hold-Down Kits 7
Hold-down screw kit for 2-pole Type BR Circuit Breakers in 1-phase MLO
Loadcenters through 125 amperes.
Hold-down screw kit for 2-pole Type BR Circuit Breakers in MLO Loadcenters 150
through 225 amperes (1-phase only).
Hold-down screw kit for 2-pole Types BJ and BJH Circuit Breakers in MLO
Loadcenters 125 through 225 amperes.
Hold-down screw kit for 3-pole Types BJ and BJH Circuit Breakers in MLO
Loadcenters 125 through 225 amperes.
Mechanical Interlocks
Types BR for 2-, 3- and 4-pole Breakers
10
BHT
10
THOW
10
THS1
BHLW2
THS1
BRLW2
10
BRLW
10
BRLW1
10
BRLW2
10
BRDL1
10
BRQLW
BREQS125
BRHDK125
BRQLW
10
BHLW
10
BHLW1
10
BHLW2
10
BHGW
10
HLW1
1
BREQS125
1
BRHDK125
1
BJHDS
1
BJHDS3P
10
BRML
Shunt Trips for BR
120V
1
ST 8
Alarm Contacts for Type GFCB (1-Pole)
Alarm Contact for GFCB (1-Pole)
(1) N.O. and (1) N.C.
1
1
W1 8
W2 8
BHLW
THOW (Installed)
BRML
BRSF125
FIeld Installation Kits and Parts
Number
of Poles
Ampere
Rating
Number of
1-inch (25.4 mm)
Spaces Needed
Wire Size Range
Cu/Al 60°C or 75°C
Ordering Catalog
Quantity Number
1
Main and Sub-Feed Lug Blocks
2
125
150
225
2
2
2
#8 – 2/0 AWG
#8 – 2/0 AWG
#2 AWG – 300 kcmil
1
1
1
BRSF125
BRSF150
BRS225
3
150
225
3
3
#8 – 2/0 AWG
#2 AWG – 300 kcmil
1
1
3BRSF150
3BRS225
1
2
3
4
5
6
7
8
3BRS225
Must be purchased in multiples of ordering quantities indicated.
Handle Ties: Typically used to join two similar independent single-pole breakers to form a 2-pole noncommon trip breaker.
Handle Lockoffs: Devices that use a padlock to lock the circuit breaker’s handle in the “On” or “Off” position.
Escutcheon Mounted: Device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.
Handle Mounted: Device mounted directly to the handle by the use of a set screw.
Handle Lockdogs: Devices that are used to secure a circuit breaker’s handle in the “On” or “Off” position. Handle Lockdogs are not padlockable devices.
Hold-Down Kits: Devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384-16(g).
Add suffix indicated to end of breaker catalog number.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Single-Phase Single-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
Page 32
70 2
AMP
4
SPACES
SINGLE POLES
DIAGRAM 18
.703
(17.86)
#10 Mounting
Screws
4.359
(110.72)
.297
.625 (7.54)
(15.88)
.156
(3.96)
1.625
(41.28)
2.250
(57.15)
1.063
(26.99)
.156 Diameter Nib
1.812
(30.02)
.031 x 45° Chamfer
1 Nib Required
2.000
(50.80)
3.563
(90.50)
.625
(15.88)
.187
(4.75)
3.000
(76.2)
3.345
(84.96) Maximum
1.063
(27.00)
2.688
(68.28)
Handle
Height
#14 - 2 AWG (Al/Cu)
1.782
(45.26)
24INT70B
125 2
AMP
SPACES
4
SINGLE POLES
DIAGRAM 19
.703
(17.86)
#10 Mounting
Screws
.297
.625 (7.54)
(15.88)
.156
(3.96)
1.625
(41.28)
2.250
(57.15)
4.359
(110.72)
1.063
(26.99)
.156 Diameter Nib
1.812
(46.02)
.031 x 45° Chamfer
1 Nib Required
2.000
(50.80)
3.563
(90.50)
.625
(15.88)
.187
(4.75)
3.000
(76.20)
3.545
(90.04) Maximum
1.063
(26.99)
2.688
(68.28)
#2/0 to 12 AWG (Al)
Handle
Height
.183
(4.65)
1.782
(45.26)
24INT125B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Single-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
TYPE
BR ASSEMBLIES
Page 33
125 6
AMP
SPACES
12
SINGLE POLES
DIAGRAM 20
(
)
Wire Range:
(1) 2/0 - 14 AWG (Al/Cu)
2.146
(54.51)
4.152
(105.46)
.218 (5.54)
2.868
(72.85)
1.795
(45.59)
3.110
(78.99)
3.655
(92.84)
Maximum
Handle
Height
.187 (4.75)
2.388
(60.66)
1.000
(25.40)
8.500
(215.90)
.310
(7.87)
9.250
(235.00)
612INT125SRB
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
Page 34
125 4
AMP
SPACES
8
125 6
SINGLE POLES
AMP
DIAGRAM 21
12
SINGLE POLES
DIAGRAM 22
1.795
(45.59)
.156 Diameter Nib
.625
(15.88)
SPACES
XXXX
(XXXX)
XXXX
(XXXX)
.031 x 45° Chamfer
1 Nib Required
2.146
(54.51)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
3.000
(76.20)
Maximum
Handle
Height
1.389
(35.28)
3.110
(78.99)
3.545
(90.04)
Maximum
Handle
Height
.187 (4.75)
.187
(4.75)
5.736 (145.69)
2.250
(57.15)
1.812
(46.02)
.703
(17.86)
.310
(7.87)
2.388
(60.66)
2.688
(68.28)
2.000
(50.80)
7.249
(184.12)
1.782
(45.26)
1.063
(26.99)
.220 Diameter
(5.59)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
#10 Mounting
Screws
3.563
(90.50)
2.868
(72.85)
CL
breaker
1.000
6.401 (25.40)
(162.59)
1.063
(26.99)
5.874
(149.20)
.218 (5.54)
612INT125B
48INT125B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
TYPE
BR ASSEMBLIES
Page 35
125 8
AMP
SPACES
16
SINGLE POLES
DIAGRAM 23
AMP
2.146
(54.51)
1.795
(45.59)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
1.389
(35.28)
Maximum
Handle
Height
2.146
(54.51)
SINGLE POLES
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
1.389
(35.28)
3.110
(78.99)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
2.868
(72.85)
5.736 (145.69)
.220 Diameter
(5.59)
.310
(7.87)
2.388
(60.66)
7.249
(184.12)
12
3.655
(92.84)
3.110
(78.99)
.310
(7.87)
SPACES
DIAGRAM 24
1.795
(45.59)
Maximum
Handle
Height
125 12
2.868
(72.85)
.220 Diameter
(5.59)
2.388
(60.66)
CL
breaker
CL
breaker
1.000
6.401 (25.40)
(162.59)
1.000
(25.40)
9.250
(235.00)
8.500
(215.90)
.218 (5.54)
816INT125B
.218 (5.54)
1212INT125B
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
Page 36
125 12
AMP
SPACES
24
SINGLE POLES
DIAGRAM 25
AMP
2.146
(54.51)
1.795
(45.59)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
24
SINGLE POLES
2.146
(54.51)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
3.655
(92.84)
1.389
(35.28)
3.110
(78.99)
Maximum
Handle
Height
1.389
(35.28)
3.110
(78.99)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
5.736 (145.69)
.310
(7.87)
SPACES
DIAGRAM 26
1.795
(45.59)
Maximum
Handle
Height
125 16
2.868
(72.85)
.310
(7.87)
.220 Diameter
(5.59)
2.868
(72.85)
.220 Diameter
(5.59)
2.388
*(70.15)
2.388
(60.66)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
9.250
(235.00)
8.500
(215.90)
11.250
(285.75)
10.500
(266.70)
.218 (5.54)
.218 (5.54)
1224INT125B
1624INT125B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
BR ASSEMBLIES
TYPE
Page 37
125 20
AMP
SPACES
24
SINGLE POLES
DIAGRAM 27
AMP
2.146
(54.51)
1.795
(45.59)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
24
2.146
(54.51)
SINGLE POLES
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
1.389
(35.28)
3.110
(78.99)
Maximum
Handle
Height
1.389
(35.28)
3.110
(78.99)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
5.736 (145.69)
.310
(7.87)
SPACES
DIAGRAM 28
1.795
(45.59)
Maximum
Handle
Height
125 24
2.868
(72.85)
.220 Diameter
(5.59)
.310
(7.87)
2.868
(72.85)
.220 Diameter
(5.59)
2.388
(60.66)
2.388
(60.66)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
13.250
(336.55)
12.500
(317.50)
15.250
(387.35)
14.500
(368.30)
.218 (5.54)
2024INT125B
.218 (5.54)
2424INT125B
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
Page 38
200 8
AMP
SPACES
16
SINGLE POLES
DIAGRAM 29
AMP
SPACES
24
2.954
(75.03)
1.391
(35.33)
Wire Range:
(1) 300 kcmil - #6 AWG (Al/Cu)
2.954
(75.03)
Wire Range:
300 kcmil - #1 AWG (Al/Cu)
3.655
(92.84)
3.655
(92.84)
3.110
(78.99)
1.500
(38.10)
Maximum
Handle
Height
3.110
(78.99)
1.500
(38.10)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
5.736 (145.69)
.310
(7.87)
SINGLE POLES
DIAGRAM 30
1.391
(35.33)
Maximum
Handle
Height
200 12
2.868
(72.85)
.310
(7.87)
.220 Diameter
(5.59)
2.868
(72.85)
.220 Diameter
(5.59)
2.762
(70.15)
2.762
(70.15)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
9.625
(244.48)
9.625
(244.48)
8.875
(225.43)
8.875
(225.43)
.218 (5.54)
.218 (5.54)
.187 (4.75)
1224INT200B
3.655
(92.84)
2.671
(67.84)
Wire Range:
300 kcmil - #6 AWG (Al/Cu)
3.110
(78.99)
2.100
(53.34)
Maximum
Handle
Height
1.530
(38.86)
816INT200B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Aluminum Bus
120/240V AC, 3-Wire
TYPE
BR ASSEMBLIES
Page 39
200 30
AMP
SPACES
40
SINGLE POLES
DIAGRAM 31
AMP
2.954
(75.03)
1.391
(35.33)
Wire Range:
300 kcmil - #1 AWG (Al/Cu)
42
2.954
(75.03)
SINGLE POLES
Wire Range:
300 kcmil - #1 AWG (Al/Cu)
3.655
(92.84)
3.655
(92.84)
3.110
(78.99)
1.500
(38.10)
Maximum
Handle
Height
3.110
(78.99)
1.500
(38.10)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
5.736 (145.69)
.310
(7.87)
SPACES
DIAGRAM 32
1.391
(35.33)
Maximum
Handle
Height
225 42
2.868
(72.85)
.220 Diameter
(5.59)
.310
(7.87)
2.868
(72.85)
.220 Diameter
(5.59)
2.762
(70.15)
2.762
(70.15)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
19.625
(498.48)
18.875
(479.43)
.218 (5.54)
25.625
(650.88)
3040INT200B
24.875
(631.83)
.218 (5.54)
4242INT225B
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
Page 40
125 8
AMP
SPACES
16
SINGLE POLES
DIAGRAM 33
AMP
2.146
(54.51)
1.795
(45.59)
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
3.655
(92.84)
1.389
(35.28)
Maximum
Handle
Height
2.146
(54.51)
SINGLE POLES
Wire Range:
(1) 2/0 - #14 AWG (Al/Cu)
1.389
(35.28)
3.110
(78.99)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
2.868
(72.85)
5.736 (145.69)
.310
(7.87)
.220 Diameter
(5.59)
2.388
(60.66)
7.249
(184.12)
12
3.655
(92.84)
3.110
(78.99)
.310
(7.87)
SPACES
DIAGRAM 34
1.795
(45.59)
Maximum
Handle
Height
125 12
2.868
(72.85)
.220 Diameter
(5.59)
2.388
(60.66)
CL
breaker
CL
breaker
1.000
6.401 (25.40)
(162.59)
1.000
(25.40)
9.250
(235.00)
8.500
(215.90)
.218 (5.54)
816INT125BC
.218 (5.54)
1212INT125BC
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Single-Phase Double-Row Breaker Mounting – Copper Bus
120/240V AC, 3-Wire
TYPE
BR ASSEMBLIES
Page 41
200 12
AMP
SPACES
24
SINGLE POLES
DIAGRAM 35
1.391
(35.33)
2.954
(75.03)
Wire Range:
300 kcmil - #1 AWG (Al/Cu)
3.655
(92.84)
Maximum
Handle
Height
3.110
(78.99)
1.500
(38.10)
.187 (4.75)
5.736 (145.69)
.310
(7.87)
2.868
(72.85)
.220 Diameter
(5.59)
2.762
(70.15)
CL
breaker
1.000
(25.40)
9.625
(244.48)
8.875
(225.43)
.218 (5.54)
1224INT200BC
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Three-Phase Double-Row Breaker Mounting – Aluminum Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
Page 42
125 12
AMP
SPACES
24
SINGLE POLES
DIAGRAM 36
150 18
AMP
SPACES
36
DIAGRAM 37
1.570
(39.88)
Wire Range:
#8 - 2/0 AWG (Al/Cu)
1.500
(38.10)
1.500
(38.10)
Wire Range:
300 kcmil - #2 AWG (Al/Cu)
3.655
(92.84)
2.811
(71.40)
1.612
(40.94)
Maximum
Handle
Height
2.572
(65.33)
3.110
(78.99)
.187 (4.75)
Unuseable
Space
5.736 (145.69)
.310
(7.87)
SINGLE POLES
2.868
(72.85)
5.736 (145.69)
.310
(7.87)
.220 Diameter
(5.59)
2.388
(60.66)
2.868
(72.85)
.220 Diameter
(5.59)
3.760
(95.50)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
13.250
(336.55)
13.625
(346.08)
12.500
(317.50)
12.875
(327.03)
.218 (5.54)
.218 (5.54)
1224INT3125B
1836INT3150B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Three-Phase Double-Row Breaker Mounting – Aluminum Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
TYPE
BR ASSEMBLIES
Page 43
150 24
AMP
SPACES
42
SINGLE POLES
DIAGRAM 38
AMP
1.500
(38.10)
1.500
(38.10)
1.570
(39.88)
Wire Range:
300 kcmil - #2 AWG (Al/Cu)
3.655
(92.84)
2.572
(65.33)
3.110
(78.99)
42
1.500
(38.10)
1.500
(38.10)
SINGLE POLES
Wire Range:
300 kcmil - #2 AWG (Al/Cu)
3.655
(92.84)
Maximum
Handle
Height
2.572
(65.33)
3.110
(78.99)
.187 (4.75)
.187 (4.75)
5.736 (145.69)
.310
(7.87)
SPACES
DIAGRAM 39
1.570
(39.88)
Maximum
Handle
Height
200 30
2.868
(72.85)
5.736 (145.69)
.220 Diameter
(5.59)
.310
(7.87)
3.760
(95.50)
2.868
(72.85)
.220 Diameter
(5.59)
3.760
(95.50)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
19.625
(498.48)
19.625
(498.46)
18.875
(479.43)
18.875
(479.43)
.218 (5.54)
.218 (5.54)
2442INT3150B
3042INT3200B
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
TYPE
BR ASSEMBLIES
Three-Phase Double-Row Breaker Mounting – Aluminum Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
Page 44
225 42
AMP
SPACES
42
SINGLE POLES
DIAGRAM 40
1.570
(39.88)
1.500
(38.10)
1.500
(38.10)
Wire Range:
300 kcmil - #2 AWG (Al/Cu)
3.655
(92.84)
Maximum
Handle
Height
2.572
(65.33)
3.110
(78.99)
.187 (4.75)
5.736 (145.69)
.310
(7.87)
2.868
(72.85)
.220 Diameter
(5.59)
3.760
(95.50)
CL
breaker
1.000
(25.40)
25.625
(650.88)
24.875
(631.83)
.218 (5.54)
4242INT3225B
Legend
Dimensions – Inches (mm)
Notched Bus Stab
Solid Bus Stab
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
Three-Phase Double-Row Breaker Mounting – Copper Bus
208Y/120V AC, 4-Wire – 240V AC, 3-Wire – 120/240V AC, 4-Wire Delta
TYPE
BR ASSEMBLIES
Page 45
125 12
AMP
SPACES
24
SINGLE POLES
DIAGRAM 41
200 12
AMP
SPACES
24
SINGLE POLES
DIAGRAM 42
1.570
(39.88)
1.500
(38.10)
1.500
(38.10)
Wire Range:
300 kcmil - #2 AWG (Al/Cu)
Wire Range:
#8 - 2/0 AWG (Al/Cu)
3.655
(92.84)
Maximum
Handle
Height
2.811
(71.40)
2.572
(65.33)
3.110
(78.99)
1.612
(40.94)
.187 (4.75)
Unuseable
Space
5.736 (145.69)
5.736 (145.69)
.310
(7.87)
2.868
(72.85)
.310
(7.87)
2.868
(72.85)
.220 Diameter
(5.59)
.220 Diameter
(5.59)
3.760
(95.50)
2.388
(60.66)
CL
breaker
CL
breaker
1.000
(25.40)
1.000
(25.40)
13.250
(336.55)
13.625
(346.08)
12.500
(317.50)
12.875
(327.03)
.218 (5.54)
.218 (5.54)
1224INT3125BC
1224INT3200BC
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OTHER
OEM PRODUCTS
Surge Protectors
Page 46
Surge Protectors
CHSA Surge Protector
CHSA — For use on single-phase,
120/240V AC systems. This easily
plugs into a single-phase Type CH
loadcenter and occupies two 3/4-inch
(19.1 mm) pole spaces similar to a
2-pole Type CH breaker. When plugged
into the first two stabs at the top of
the loadcenter just below the main
breaker or main lug, it provides surge
protection for the entire loadcenter. If
internal components are damaged, the
CHSA LED visual indicators will signal
the need for replacement. This device
is suitable for service entry locations
installed in accordance with NEC
Article 280. The CHSA is ideal for
protecting sensitive appliances and
electronics, such as refrigerators,
microwave ovens, and home
computers.
BRSURGE — For use on single-phase,
120/240V AC systems. This easily
plugs into a single-phase Type BR
loadcenter and occupies two 1-inch
(25.4 mm) pole spaces similar to a
2-pole Type BR breaker. When plugged
into the first two stabs at the top of
the loadcenter just below the main
breaker or main lug, it provides surge
protection for the entire loadcenter. If
internal components are damaged, the
BRSURGE LED visual indicators will
signal the need for replacement. This
device is suitable for service entry
locations installed in accordance with
NEC Article 280. The BRSURGE is ideal
for protecting sensitive appliances
and electronics, such as refrigerators,
microwave ovens, and home
computers.
BRSURGE Surge Protector
Surge Products
Product
Catalog Number
Stage 1 Protection
CHSP Micro™
CHSPMICRO
CHSPMICRO230INT 1
CHSP Max™
CHSPMAX
CHSPMAX230INT 1
CHSP 3-Way™
CHSPCHSR4P
CHSP Ultra™
CHSPULTRA
CHSP (Cutler-Hammer
Surge Protector)
Primary Protection for Service Entrance
The best place to install surge protection is at the electrical entrance point.
The service entrance (loadcenter
or breaker panel) is often where AC
power, telephone lines and cable lines
are located. Applying a CHSP product
to your service entrance will reduce
a voltage surge to an acceptable level
for appliances and surge strips. For
added protection, it is recommended
that you install surge protection for
your cable and telephone lines (see
accessories) at the service entrance.
The benefit of installing these products is that your AC, cable and telephone lines will all have the same
ground potential, in one common
location, for passing the surge
away from your equipment.
Accessories
SurgeTel™
DHW4PT
SurgeCable™
DCXCAB2
SurgeEthernet™
DRJ45D30R
Flushmount Kit™
CHSPFMKIT
1
230V, 50 Hz international applications.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OTHER
OEM PRODUCTS
Page 47
Notes
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
OTHER
OEM PRODUCTS
Page 48
Notes
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
For more information on Cutler-Hammer products, call 1-800-525-2000 or
1-616-982-1059, for engineering services call 1-800-498-2678, or visit our
website at www.cutlerhammer.eaton.com
Publication No. B.31.02.S.E
February 2001
Printed in U.S.A. / CMS 7402
B3102SE
Cutler-Hammer, a part of Eaton Corporation, is a worldwide leader
providing customer-driven solutions. From power distribution and electrical
control products to industrial automation, Cutler-Hammer utilizes advanced
product development, world-class manufacturing, and offers global
engineering services and support.
Download