Time and Energy Controls for a Dynamic World!

advertisement
GE Consumer & Industrial
Grasslin Controls Corporation
Time and Energy Controls
for a Dynamic World!
For the past 25 years Grasslin
has been on the forefront of
innovation by providing top
quality time and energy control
devices to the North American
market. Our time switches are
designed to meet today’s energy
conservation initiatives and
tomorrow’s environmental
demands. Grasslin products can
be found around the world
embedded into: Commercial
Refrigeration Equipment,
Lighting Control Panel, Pool and
Spa Controls, Gate Operators,
Residential In-Wall Timers, and
many more applications.
imagination at work
Contents
ELECTROMECHANICAL TIME CONTROLS
24 Hour Electromechanical Time Switches
TimeMaster – GM40 Series............................................... 2
TimeMaster – GMX Series ................................................. 4
Water Heater Timer ............................................................ 5
MIL 72A, E................................................................................ 6
FM/1, KM2 Models................................................................16
KM2 In-Wall ............................................................................20
7 Day Electromechanical Time Switches
TimeMaster – GM40 Series............................................... 2
TimeMaster – GMX Series ................................................. 4
MIL 72A, E................................................................................ 6
FM, FM/1 Models ..................................................................16
KM2 In-Wall ............................................................................20
1 Hour Electromechanical Time Switch
TALENTO-121 ......................................................................... 7
12 Hour Electromechanical Time Switches
FM/1 S12hu ............................................................................ 7
ELECTRONIC TIME CONTROLS
One Channel Electronic Time Switches
TimeMaster – GM40 Series............................................... 8
TimeMaster – GMX Series ................................................. 9
Digi 20A, E ...............................................................................12
Digi 42A, E ...............................................................................12
TALENTO-471 (24-hr/7-day) .............................................14
TALENTO-891 (365 day)......................................................14
FM/1 Digi 20 & 42, FM/1 Digi 14.....................................17
Two Channel Electronic Time Switches
(24-hour, 7-day, and 365-day)
TimeMaster – GMX Series .................................................15
Digi 42/2 ..................................................................................13
TALENTO-472 (24-hr/7-day) .............................................14
TALENTO-892 (365 day)......................................................14
Four Channel Electronic Time Switches
TALENTO-894 (365 day)......................................................14
Eight Channel Electronic Time Switch
SRS-3800 .................................................................................15
Electronic 24-hour/7-day In Wall Timer
ET724 ........................................................................................21
LIGHTING CONTROLS
LightMaster – LM1, LM2.....................................................22
Light Sensors .........................................................................22
Photo Controls.......................................................................24
POOL & SPA TIME CONTROLS
TimeMaster – GM Series.................................................... 2
TimeMaster – GMX Series ................................................. 4
MIL 72A, E................................................................................ 6
FM/1 ..........................................................................................16
FM/1 digi 20 & 42 .................................................................17
Digi 20/42A, E ........................................................................12
DEFROST CONTROLS–COMMERCIAL REFRIGERATION
FrostKing – DTMV40 ............................................................10
FrostKing – DT140 Electronic...........................................11
INTERVAL TIMERS
KLT – Spring-Wound............................................................18
ET616 – Electronic................................................................19
HOUR METERS—AC, DC, VIBRATORY
FWZ............................................................................................26
UWZ...........................................................................................27
GZ ...............................................................................................28
RZ................................................................................................28
PLUG-IN TIMERS...............................................................................29
SPECIAL PURPOSE TIME CONTROLS
FM/1 digi 14 Electronic Timer Module .........................21
ENCLOSURES.....................................................................................31
ACCESSORIES ....................................................................................31
MODEL CODE INDEX...................................................................... 2
REPLACEMENT CROSS REFERENCE .........................................32
COMPETITIVE CROSS REFERENCE .....................................33-34
GRASSLIN SALES REPRESENTATIVES.................................35-36
APPLICATION HINTS ................................................................37-40
GENERAL INFORMATION
AND WARRANTY ............................................ Inside Back Cover
Model Code Index
Model Code
Page
Model Code
Page
Model Code
Page
BAT-42 ............................................................................31
FM/1 SWuZ ..................................................................16
KM2STU-2G .................................................................20
BAT-Lithium .................................................................31
FWZ 36 ...........................................................................26
LM1 .................................................................................22
BEZ-55 Black ...............................................................31
FWZ 53 ...........................................................................26
LM1-digi20....................................................................23
BEZ-55 Gray ................................................................31
FWZ 55 ...........................................................................26
LM2 .................................................................................22
BEZ-72 ...........................................................................31
FWZ 55K ........................................................................26
LM2-digi30....................................................................23
BEZ-72P ........................................................................31
FWZ 72 ...........................................................................26
MB-48Y...........................................................................30
BT-120 ...........................................................................25
FWZ 72B ........................................................................26
MB-DIN ..........................................................................31
BT-287 ...........................................................................25
G-55.................................................................................31
MB-FMPC ......................................................................31
BTW-120........................................................................25
GZ-55 ..............................................................................27
MIL72AQTUZH................................................................6
CM-120 ..........................................................................24
GZ-72 ..............................................................................27
MIL72AQWUZH .............................................................6
CM-127 ..........................................................................24
GM40 .................................................................................2
MIL72ASTUZ....................................................................6
CM-287 ..........................................................................24
GM40E...............................................................................8
MIL72ASTUZH ...............................................................6
CMM-1120 ...................................................................24
GMX-digi20 ....................................................................9
MIL72ASWUZ .................................................................6
CMM-1127 ...................................................................24
GMX-digi42 ....................................................................9
MIL72ASWUZH...............................................................6
CMP-120 .......................................................................24
GMX471..........................................................................14
PC1...................................................................................22
CMP-287 .......................................................................24
GMX472..........................................................................14
PC1-digi20 ....................................................................23
CMS-120 ........................................................................24
GMX891..........................................................................14
PC2...................................................................................22
CMS-287 ........................................................................24
GMX892..........................................................................14
PC2-digi30 ....................................................................23
CP924..............................................................................30
GMX894..........................................................................14
DC-FME ..........................................................................31
GMXQT ..............................................................................4
DC-KM2 .........................................................................31
GMXQW ............................................................................4
DIGI20A .........................................................................12
GMXST...............................................................................4
DIGI20E ..........................................................................12
GMXSW ............................................................................4
DIGI42/2 .......................................................................13
GZ40A ............................................................................28
DIGI42A .........................................................................12
GZ40B .............................................................................28
DIGI42E ..........................................................................12
GZ41................................................................................28
DIN-12 ............................................................................31
GZ52A/B.........................................................................28
DIN-4...............................................................................31
KLT12H ..........................................................................18
DTMV40..........................................................................10
KLT15M...........................................................................18
DTQMV40.......................................................................10
KLT2H .............................................................................18
DT140-digi20 ..............................................................11
KLT30M...........................................................................18
E110.................................................................................31
KLT4H .............................................................................18
E150.................................................................................31
KLT5M .............................................................................18
E150C..............................................................................31
KLT60M...........................................................................18
E200.................................................................................31
KLT6H .............................................................................18
E200C..............................................................................31
KM2 STuH .....................................................................20
E300.................................................................................31
KM2 SWuH....................................................................20
ET616 .............................................................................19
KM2ST-1G ....................................................................20
TLD-1480.......................................................................25
ET724 .............................................................................21
KM2ST-2D ....................................................................20
TLD-287..........................................................................25
FM/1 Digi14 .................................................................17
KM2ST-2G ....................................................................20
UWZ 48 ..........................................................................27
FM/1 Digi20 .................................................................17
KM2ST-2R......................................................................20
UWZ 48A........................................................................27
FM/1 Digi42 .................................................................17
KM2ST-3D ....................................................................20
UWZ 48E........................................................................27
FM/1 QTuZ.....................................................................16
KM2ST-3G ....................................................................20
UWZ 48V .......................................................................27
FM/1 QWuZ .................................................................16
KM2ST-4G ....................................................................20
UWZ 52E........................................................................27
FM/1 S 12H ....................................................................7
KM2STST-2G ................................................................20
WH-4 .................................................................................5
FM/1 STuZ ....................................................................16
KM2STU-1G .................................................................20
WH-7 .................................................................................5
www.grasslin.com
201-825-9696
RCB ..................................................................................25
RZ 52 ..............................................................................28
RZ 60 ..............................................................................27
SC ....................................................................................25
SRS3800.........................................................................11
TD150..............................................................................30
T240 ...............................................................................29
T25 ..................................................................................29
T35 ..................................................................................29
TALENTO-121 ................................................................7
TALENTO-471 ..............................................................14
TALENTO-472 ..............................................................14
TALENTO-891 ..............................................................14
TALENTO-892 ..............................................................14
TALENTO-894 ..............................................................14
TAXXI-DIALOG-SET .....................................................14
TLD-1185.......................................................................25
TLD-120..........................................................................25
1
Electromechanical Time Controls
GM40 Series (24-Hour/7-Day)
Multi-Voltage General Purpose Time Switch
The GM40 Multi-Volt Series Time Controls are universal, electromechanical time switches which can be field configured for various power
supply voltages. The voltage options include 120VAC, 208/240VAC, and 277VAC, all within the same unit! Selection of the desired supply voltage is easily achieved by selecting the DIP to the corresponding input voltage. The mechanism is mounted in a compact NEMA 3R outdoor
enclosure and features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts). All GM40 models are available as “Mechanism Only” (–M) for installation in other enclosures or control panels or “Bracket Mount” (- B). The GM40 is also
available in a NEMA 1 Indoor Metal Enclosure (-IM).
APPLICATION: The GM40 is a robust time switch capable of switching high amperage. Below are samples of the many applications where
the GM40 can be used::
• Lighting Control
• Access Control
• Heating, Air-Conditioning
• Agricultural Facilities
• Pumps/Motors/Fan Control
• General Purpose Electrical Circuits
Amber and Green
LED Lights Indicate
Power and Status
Easy Multi-Voltage
Field Adjustable
DIP Switch for
120, 208/240,
or 277 VAC
Covered by U.S. Patent #6,563,237
RoHS Compliant 2002/95/EC
File #E83486 1 Year Warranty
Captive Trippers
Can’t Be Lost
Independently
Adjustable Trippers at
15 Minute Intervals
(2 hrs. for 7-day model)
True Clock Face
with ON/OFF/AUTO
Override Switch
New Compact
VALOX® NEMA 3R
Outdoor Enclosure
is Standard
NO TOOLS REQUIRED!
Our “GUTS” simply snap
into existing Grasslin or
Intermatic enclosures
40 Amp
Rated Contacts
Large Screw
Terminals for Easy Wiring
#8 AWG
Ground Lug Termination
2
Moisture Resistant
Conformal Coated Board
SPDT and DPDT
ALL-IN -ONE!
www.grasslin.com
201-825-9696
Electromechanical Time Controls
GM40 Series Ordering Data
VOLTAGE
MODEL
OUTPUT
BATTERY BACKUP
24-Hour Electromechanical, Multi-Voltage, SPDT/DPDT, NEMA 3R Outdoor Enclosure
120, 208~240, 277VAC
40A DPDT
GM40
GM40Q
120, 208~240, 277VAC
40A DPDT
—
Yes
7-Day (Skip-A-Day/Weekly) Electromechanical, Multi-Voltage, SPDT/DPDT, NEMA 3R Outdoor Enclosure
120, 208~240, 277VAC
120, 208~240, 277VAC
GM40W
GM40QW
40A DPDT
40A DPDT
—
Yes
40A DPDT
40A DPDT
—
Yes
24-Hour Electromechanical, Multi-Voltage, SPDT/DPDT, Mechanism Only
120, 208~240, 277VAC
120, 208~240, 277VAC
GM40-M
GM40Q-M
7-Day (Skip-A-Day/Weekly) Electromechanical, Multi-Voltage, SPDT/DPDT, Mechanism Only
GM40W-M
GM40QW-M
120, 208~240, 277VAC
120, 208~240, 277VAC
40A DPDT
40A DPDT
GM40 MultiVolt Cross Reference
GM40
24 Hour
Intermatic
T101
T101(B)
T102
T102(B)
T105
T185
T1905
T1906
Tork
1101
1102
8001
8004
T101P
T101R
T101(B)
T102P
T102R
T102(B)
T106R
T1905R
T1906R
1101-N
1102-N
8001-N
8004-N
T101
T102
T103
T104
T105
1101
1102
1103
1104
T103
T103P
T103R
T104
T104P
T104R
Paragon
P101
4001-00
4002-71
4005-00
P101P
4011-00(P)
GM40W
7 Day
1101-N
1102-N
1103-N
1104-N
8002N
8042N
P103
P104
4003-00
4004-71
GM40 Wiring Diagrams
Intermatic
Tork
Paragon
T171
T172
T171B
T172B
T175
T176
T1975
T1976
T2005
T2006
7100
7102
7120
7122
W100
W120
P101-S
1015-00RS
1015-00RSB
42011-00
42011-20
4005-00S
4005-00SB
4006-71S
T173
T174
T1871BR
T1872BR
T7801B
T7802B
7200
7202
7220
7222
W200
W202
W220
W222
8004
8007
8008
P103P
P104P
4011-00(P)
4013-00
4014-71
4003-00S
4003-00S
4004-71S
4013-SS0
4014-71S
P103-S
P103-PS
P104-S
P104-PS
42013-00
42013-20
7008-00
7008-71
T7401/2B
www.grasslin.com
WIRING CONNECTIONS:
Screw box lug terminals
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–40°F to 131°F (–40°C to 55°C)
Operating Humidity: 0 to 95% non-condensing
ENCLOSURE DIMENSIONS:
8.795” x 6.631” x 2.935” (H x W x D)
SHIPPING WEIGHT: 3 lbs.
ELECTRICAL LIFE:
50,000 Operations at Full Load
SWITCH CONFIGURATION:
DPDT (2-N.O. and 2-N.C. Contacts)
BATTERY BACKUP OPTION: 7 Days
201-825-9696
TIMER
T Wiring Diagram (120VAC Application)
TIMER
Typical
T
TIMER
NO
L1
L2/N
NC
NC2
NO2 COM2
COM
T
L1
L2/N
NC
NO
COM
NO2
COM2
L1
L2/N
NC
NO
NC2
NO2
COM LOAD
COM2
H
N
120VAC
H
N
120VAC
H
N
120VAC
NC2
LOAD
LOAD
Typical Wiring Diagram (240VAC Application)
TIMER
T
TIMER
T
TIMER
L2/N
L1
T
NC
NO
COM
NC2
NO2
COM2
L1
L2/N
NC
NO
COM
NC2
NO2
COM2
L1
L2/N
NC
NO
NC2
COM
LOAD
NO2
COM2
L2
L1
240VAC
L1
L2
240VAC
L1
L2
Typical
Wiring
240VAC
TIMER
T
TIMER
T
TIMER
L1
L2/N
T
LOAD
LOAD
Diagram (277VAC Application)
NC
NO
COM
NC2
NO2
COM2
L1
L2/N
NC
NO
COM
NC2
NO2
COM2
L1
L2/N
NC
NO
COM
LOAD
#1
LOAD
#1
NC2
NO2 LOAD
COM2
W400A/402A
All GM40 models are available with Battery Backup (200 hours carryover) and/or Metal Enclosure.
ELECTRICAL RATINGS:
N.O. Contacts:
40A Resistive @ 120~277VAC
1HP, 16FLA, 90LRA @ 120VAC
2HP, 12FLA, 52LRA @ 208~277VAC
30A Ballast @ 120VAC
20A Ballast @ 277VAC
15A Tungsten @ 120VAC
300VA Pilot Duty 120~240VAC
N.C. Contacts:
30A Resistive @ 120~277VAC
1HP, 12FLA, 30LRA @ 120VAC
2HP, 10FLA, 30LRA @ 240VAC
2A Tungsten @ 120VAC
10A Ballast @ 277VAC
—
Yes
H
N
277VAC
H
N
277VAC
H
N
277VAC
LOAD
#1
#2
LOAD
#2
LOAD
#2
SPECIFIERS GUIDE
Furnish and install a Grasslin GM40 _ Multi-Volt Series 24
hour or (7 day) time switch with captive trippers and quartz or
synchronous drive. Input voltage shall be 120, 208/240 or
277VAC selectable via simple to set DIP switch. All units shall
incorporate both SPDT and DPDT contacts that shall be rated
at 40A, 2 HP @ 277V. To set the starting time and to provide
time indication, the unit shall have an authentic clock face
with hour and minute hands. LED indicators shall provide
Power and Status feedback. Enclosure shall be NEMA 3R suitable for both indoor or outdoor installation. Time switch shall
contain an OFF/AUTO/ON manual override. For Carry-over:
The time switch shall have a quartz drive with 7 day reserve
carry-over.
3
Electromechanical Time Controls
GMX Series (24-Hour/7-Day)
General Purpose Time Switch
The GMX Series Time Controls are universal, electromechanical time switches. They are a low
cost alternative for applications that do not require more than 21A or 2HP @240VAC. The unit
is mounted in a NEMA 1 Indoor or NEMA 3R Outdoor enclosure.
APPLICATION: The GMX is a light duty commercial time switch ideal for 24, 120, or 277 VAC single phase applications such as:
• Access Control
• Lighting Control
• Heating, Air-Conditioning
• Agricultural Facilities
• Pumps/Motors/Fan Control
• General Electrical Circuits
ELECTRICAL RATINGS:
SPDT Contacts:
21A Resistive @ 120~250VAC
1HP @ 120VAC
2HP @ 240VAC
1,350W Tungsten @ 240VAC
WIRING CONNECTIONS:
Screw terminals accepts up to
12AWG wire
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–40°F to 180°F (–40°C to 82°C)
–40°F to 140°F w/Battery Backup
(–40°C to 60°C)
Operating Humidity: 0 to 95% non-condensing
ENCLOSURE DIMENSIONS:
10” x 6.50” x 3.75” (H x W x D)
SHIPPING WEIGHT: 2 lbs.
ELECTRICAL LIFE:
6,000 Operations at Full Load
SWITCH CONFIGURATION:
SPDT (1-N.O. and 1-N.C. Contacts)
BATTERY BACKUP OPTION: 7 Days
VOLTAGE
OUTPUT
BATTERY BACKUP
24-Hour Electromechanical, SPDT, NEMA 1 Indoor Enclosure
GMXST-I-120
120VAC, 60Hz
21A SPDT
GMXQT-I-120
120VAC, 50/60Hz
21A SPDT
Yes
GMXST-I-240
240VAC, 60Hz
21A SPDT
GMXQT-I-240
240VAC, 50/60Hz
21A SPDT
Yes
GMXST-I-277
277VAC, 60Hz
21A SPDT
GMXST-I-24
24VAC, 60Hz
21A SPDT
GMXQT-I-24
24VAC, 50/60Hz; 12~24VDC
21A SPDT
Yes
7-Day (Skip-A-Day/Weekly) Electromechanical, SPDT, NEMA 1 Indoor Enclosure
GMXSW-I-120
GMXQW-I-120
GMXSW-I-240
GMXQW-I-240
GMXSW-I-277
GMXSW-I-24
GMXQW-I-24
120VAC, 60Hz
120VAC, 50/60Hz
240VAC, 60Hz
240VAC, 50/60Hz
277VAC, 60Hz
24VAC, 60Hz
24VAC, 50/60Hz; 12~24VDC
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
Yes
Yes
Yes
24-Hour Electromechanical, SPDT, NEMA 3R Outdoor Enclosure
GMXST-O-120
120VAC, 60Hz
21A SPDT
GMXQT-O-120
120VAC, 50/60Hz
21A SPDT
Yes
21A SPDT
240VAC, 60Hz
GMXST-O-240
GMXQT-O-240
240VAC, 50/60Hz
21A SPDT
Yes
277VAC, 60Hz
21A SPDT
GMXST-O-277
24VAC, 60Hz
21A SPDT
GMXST-O-24
GMXQT-O-24
24VAC, 50/60Hz; 12~24VDC
21A SPDT
Yes
7-Day (Skip-A-Day/Weekly) Electromechanical, SPDT, NEMA 3R Outdoor Enclosure
GMXSW-O-120
GMXQW-O-120
GMXSW-O-240
GMXQW-O-240
GMXSW-O-277
GMXSW-O-24
GMXQW-O-24
4
120VAC, 60Hz
120VAC, 50/60Hz
240VAC, 60Hz
240VAC, 50/60Hz
277VAC, 60Hz
24VAC, 60Hz
24VAC, 50/60Hz; 12~24VDC
File #E83486
FEATURES
GMX Series Ordering Data
MODEL
1 Year Warranty
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
21A SPDT
Yes
Yes
Yes
•
•
•
•
21 Amp. Rating
NEMA 1 Indoor or 3R Outdoor Enclosure
SPDT Switch
Captive trippers with intervals of 15 minutes on
24-hour models (2hours on 7-day models)
• True clock face, easy to set
• Finger safe terminals
• Enclosure provides space for field added
contactor or other accessories.
GMX Wiring Diagram
Typical Wiring Diagram (120VAC Application)
Timer
T
1
2
H
N
3
COM
4
N.O.
5
N.C.
LOAD
120VAC
SPECIFIERS GUIDE
Furnish and install a Grasslin GMX ___ 24 hour (7 day) time
sFurnish and install a Grasslin GMX ___ 24 hour (7 day) time
switch with captive trippers and quartz (synchronous) drive.
Input voltage shall be 120V (24V, 240V, 277V) and SPDT contacts shall be rated at 21A, 2 HP @ 240VAC. To set the starting time and to provide time indication, the unit shall have
an authentic clock face with hour and minute hands.
Enclosure to be NEMA 1 (NEMA 3R rain tight). Time switch
shall contain an OFF/AUTO/ON manual override. For Carryover: The time switch shall have a quartz drive with 7 day
minimum reserve carry-over.
www.grasslin.com
201-825-9696
Electromechanical Time Controls
WHQ Series (24-Hour/7-Day)
Water Heater Timers w/Battery Backup
The WHQ Series Water Heater Timers are designed for control of residential, commercial, or industrial electric water heaters up to 10,000 Watts capacity running at
208/240VAC. The unit is mounted in a NEMA 3R Outdoor enclosure and can be
placed in basements or mechanical rooms.
APPLICATION: This unit is designed to save energy and maximize hot water usage
throughout the day. For example, the unit could be programmed to turn ON during
periods of high usage such as in the early morning hours and OFF during low
demand periods such as late evenings.
ELECTRICAL RATINGS:
N.O. Contacts:
40A Resistive @ 250VAC
10,000 Watts
N.C. Contacts:
30A Resistive @ 250VAC
7,500 Watts
WIRING CONNECTIONS:
Screw box lug terminals
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–40°F to 131°F (–40°C to 55°C)
Operating Humidity: 0 to 95% non-condensing
ENCLOSURE DIMENSIONS:
8.795” x 6.631” x 2.935” (H x W x D)
SHIPPING WEIGHT: 3 lbs.
ELECTRICAL LIFE:
50,000 Operations at Full Load
SWITCH CONFIGURATION:
DPDT (2-N.O. and 2-N.C. Contacts)
BATTERY BACKUP: 7 Days
WHQ Series Ordering Data
MODEL
VOLTAGE
OUTPUT
24-Hour Electromechanical, DPDT, NEMA 3R Outdoor Enclosure
WHQ-4
208~240VAC, 60Hz
40A DPDT
BATTERY BACKUP
Yes
Covered by U.S. Patent #6,563,237
2 Year Warranty
File #E83486
FEATURES
• 40 Amp. Rating
• Saves energy by shutting heaters OFF during
“off-peak” periods
• Captive trippers with easy to read clock face
• Manual Override
• Power and Status LED Indicators
• Ground Lug
• Built-In Battery Backup Standard
• Raintight NEMA 3R Enclosure
• True Clock Face
7-Day (Skip-A-Day/Weekly) Electromechanical, DPDT, NEMA 3R Outdoor Enclosure
WHQ-7
208~240VAC, 60Hz
40A DPDT
Yes
WHQ Series Wiring Diagram
Typical Wiring Diagram (240VAC Application)
TIMER
T
SPECIFIERS GUIDE
L1
Furnish and install a Grasslin WHQ ___ Water Heater Time Control with captive trippers and
quartz (battery backup) drive. Input voltage shall be 208/240VAC on all models. Contacts
shall be (DPDT) rated at 40A, 10,000 Watts @ 250VAC. To set the starting time and to provide
time indication, the unit shall have an authentic clock face with hour and minute hands.
Enclosure to be NEMA 3R rain-tight. Time switch shall contain an OFF/AUTO/ON manual
override.
L2/N
NC
NO
COM
NC2
NO2
COM2
LOAD
L1
L2
240VAC
T
www.grasslin.com
201-825-9696
5
Electromechanical Time Controls
MIL72 Series (24-Hour/7-Day)
Surface or Flush Mounted Time
Switches
The MIL72 Series time switches are designed to be mounted
inside a control panel and can accommodate surface/DIN rail or
flush/panel mounting.
APPLICATION: The MIL72 Series is a light duty commercial time
switch ideal for 24, 120, or 277VAC single phase applications
such as:
MIL 72E
(Flush Mounting)
• Lighting Control
• Heating, Air-Conditioning, Refrigeration
• Pumps/Motors/Fan Control
MIL 72A
(Surface Mounting)
• Access Control
UL File #E83486
CSA File #LR52379
• Agricultural Facilities
C
• General Purpose Electrical Circuits
FEATURES
ELECTRICAL RATINGS:
SPDT Contacts:
21A Resistive @ 120~250VAC
1HP @ 120VAC
2HP @ 240VAC
1,350W Tungsten @ 240VAC
WIRING CONNECTIONS:
Screw terminals accepts up to 12AWG
wire
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–40°F to 180°F (–40°C to 82°C)
C
• Synchronous drive or quartz drive with battery backup
• 21A SPDT switch
• Captive trippers with interval as low as 15 minutes
• With or without 3-way override
• True clock face
• Surface, flush, or DIN rail mount
–40°F to 131°F w/Battery Backup
(–40°C to 55°C)
Operating Humidity: 0 to 95% non-condensing
MIL72E Cutout:
2-5/8” x 2-5/8” (66mm x 66mm)
SHIPPING WEIGHT: 1 lbs.
ELECTRICAL LIFE:
6,000 Operations at Full Load
SWITCH CONFIGURATION:
SPDT (1-N.O. and 1-N.C. Contacts)
BATTERY BACKUP OPTION: 7 Days
MIL72 Wiring Diagram
Typical Wiring Diagram (120VAC Application)
Timer
T
SPECIFIERS GUIDE
Furnish and install a Grasslin MIL 72____ 24 hour (7 day) time switch with 15 min. (2 hour) interval captive trippers and quartz (synchronous) drive. Input voltage shall be 120V (24V, 240V, 277V)
and SPDT switch contacts shall be rated at 21A, resistive, 2HP @ 250VAC. To set the starting time
and to provide time indication, the unit shall incorporate an authentic clock face. Installation for
surface, (flush, DIN rail or within indoor or outdoor enclosure) mounting. Time switch shall contain an OFF/AUTO/ON override. For Carry-over: The time controls shall have a quartz drive with
7 day reserve carry-over from a rechargeable battery.
1
2
H
N
3
COM
4
N.O.
5
N.C.
LOAD
120VAC
MIL72 Series Ordering Data
Complete Model Number = MIL 72A or E followed by suffix code and voltage Example: MIL 72A STuZ–24
Synchronous
Without
Override
Quartz–7 Day Carry-Over**
With 3 Way
Override
With 3 Way Override
Input
Voltage
Switch
Rating
250V Res.
Minimum
On/Off
Time
Event
On/Off
Time
24VAC
120VAC
208/240VAC
277VAC
SPDT 21A
SPDT 21A
SPDT 21A
SPDT 21A
15 min.
15 min.
15 min.
15 min.
ON 1/4 hr.
ON 1/4 hr.
ON 1/4 hr.
ON 1/4 hr.
24VAC
120VAC
208/240VAC
277VAC
SPDT 21A
SPDT 21A
SPDT 21A
SPDT 21A
2 hr.
2 hr.
2 hr.
2 hr.
ON 2 hr.
ON 2 hr.
ON 2 hr.
ON 2 hr.
MIL 72A–Surface Mount
MIL 72E–Flush Mount24 HOUR TIME CONTROL
STuZ–24
STuZ–120
STuZ–240
STuZH–24
STuZH–120
STuZH–240
STuZH–277
MIL 72A–Surface Mount
MIL 72E–Flush Mount
SWuZ–24
SWuZ–120
SWuZ–240
QTuZH–24
QTuZH–120
QTuZH–240
7 DAY TIME CONTROL
SWuZH–24
SWuZH–120
SWuZH–240
SWuZH–277
QWuZH–24
QWuZH–120
QWuZH–240
**Quartz 24VAC models will operate on 12~24VDC
6
www.grasslin.com
201-825-9696
Electromechanical Cycle Time Switches
Talento 121
One Hour Repeat Cycle Time Switch
FEATURES
The talento 121 is a synchronous motor driven electromechanical
one hour time switch intended as a low cost repeat cycle timer for
industrial processes and other applications. It provides continuous on
and off cycling of a load in a pattern which will repeat every hour.
Captive trippers allow setting up to 24 on and 24 off times in 1.25
minute increments over a one hour period. It may be used in conjunction with a GRASSLIN 24 hour or 7 day time switch to provide repeat
cycle timed switching only during selected periods of the day or
week. It may be surface or DIN rail mounted within panels, or may be
mounted in a GRASSLIN indoor or outdoor enclosure.
• 1.25 minute resolution
• Up to 24 ON/OFF
times per hour
• Captive trippers
• SPDT 16A switch
• Surface or DIN rail
mounting
SPECIFICATIONS
SIZE: 2.13” x 3.31” x 2.56” deep
SWITCH OUTPUT: SPDT isolated contacts
16A Resistive @ 125/250VAC
4A Inductive @ 125/250VAC
1350W Tungsten @ 240V
SHORTEST SWITCHING TIME: 1.25 Minutes
OPERATING TEMPERATURE: –13°F to 130°F
OPERATING HUMIDITY: 0 to 95%
RH non-condensing
WIRING CONNECTIONS: Screw terminals for up to #12AWG wire
talento 121 Wiring Diagram
FM/1 S 12H
12 Hour Repeat Cycle Time Switch
The FM/1 S 12H is a synchronous motor driven electromechanical 12 hour time switch
intended as a low cost repeat cycle timer for industrial processes and other applications. It provides continuous on and off cycling in a pattern which will repeat every 12
hours. Captive trippers allow setting up to 48 ON and 48 OFF times in 7.5 minute increments over a 12 hour period.
SPECIFICATIONS:
SIZE: 2.36” x 2.36” x 1.25”
SUPPLY VOLTAGE: 24, 120, 240VAC
POWER CONSUMPTION: 1VA
SWITCH RATING: SPDT
Resistive: 21A
Tungsten: 1350W
Inductive: 1HP @ 120VAC
2HP @ 240VAC
WIRING CONNECTIONS: 1/4” quick-connects
INSTALLATION:
Stand Alone: With indoor or
outdoor enclosure
Panel: Surface mounting
FEATURES
• 12 hour cycle
• 7.5 minute resolution
• Captive trippers
C
• SPDT 21A switch
• Flush, surface or DIN rail mounting
File #LR52379
File #E83486
C
talento 121 and FM/1 S 12H Ordering Data
Model
Voltage
Carryover
Switch Program
Minimum
ON/OFF Time
Switch Output
talento 121
120V or 240V
No
One Hour
1.25 minutes
SPDT 16A Res.
FM/1 S 12H
24V, 120V, 240V
No
12-Hour
7.5 minutes
SPDT 21A Res.
www.grasslin.com
201-825-9696
7
Electronic Time Controls
GM40E Series (24-Hour and/or 7-Day All-in-one)
Electronic General Purpose Time Switch
The GM40E Series Time Controls are universal, electronic time switches designed for general
purpose commercial applications. Available in voltage specific 120VAC, 208/240VAC or 277VAC
60/50Hz. The mechanism is mounted in a NEMA 3R outdoor enclosure and features a DPDT
switching configuration standard (i.e. two normally open and two normally closed contacts). .
All GM40E models are available as “Mechanism Only” ( -M) for installation in other enclosures
or control panels or “Bracket Mount” ( -B). The GM40E is also available in a NEMA 1 Indoor Metal
Enclosure ( -IM).
APPLICATION: The GM40E is a robust time switch capable of switching high amperage. Below
are samples of the many applications where the GM40E can be used:
• Lighting Control
• Access Control
• Heating, Air-Conditioning
• Agricultural Facilities
• Pumps/Motors/Fan Control
• General Electrical Circuits
ELECTRICAL RATINGS:
N.O. Contacts:
40A Resistive @ 120~277VAC
1HP, 16FLA, 90LRA @ 120VAC
2HP, 12FLA, 52LRA @ 208~277VAC
30A Ballast @ 120VAC
20A Ballast @ 277VAC
15A Tungsten @ 120VAC
300VA Pilot Duty 120~240VAC
N.C. Contacts:
30A Resistive @ 120~277VAC
1HP, 12FLA, 30LRA @ 120VAC
2HP, 10FLA, 30LRA @ 240VAC
2A Tungsten @ 120VAC
10A Ballast @ 277VAC
WIRING CONNECTIONS:
Screw box lug terminals
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–40°F to 131°F (–40°C to 55°C)
Operating Humidity: 0 to 95%
non-condensing
ENCLOSURE DIMENSIONS:
8.795” x 6.631” x 2.935” (H x W x D)
SHIPPING WEIGHT: 3 lbs.
ELECTRICAL LIFE:
50,000 Operations at Full Load
SWITCH CONFIGURATION:
DPDT (2-N.O. and 2-N.C. Contacts)
BATTERY BACKUP: 7 Days
GM40E Series Ordering Data
MODEL
VOLTAGE
OUTPUT
PROGRAMS
BATTERY BACKUP
24-Hour/7-Day Electronic, DPDT, NEMA 3R Outdoor Enclosure
GM40E-120
120VAC, 50/60Hz
40A DPDT
14
Yes
GM40E-240
240VAC, 50/60Hz
40A DPDT
20
Yes
GM40E-277
277VAC, 60Hz
40A DPDT
20
Yes
24-Hour/7-Day Electronic, DPDT, NEMA 3R Outdoor Enclosure w/Automatic Daylight
Saving Adjustment
GM40E42-120
120VAC, 50/60Hz
40A DPDT
42
Yes
GM40E42-240
240VAC, 50/60Hz
40A DPDT
42
Yes
GM40E42-277
277VAC, 60Hz
40A DPDT
42
Yes
24-Hour/7-Day Electronic, DPDT, Mechanism Only
GM40E-M-120
120VAC, 50/60Hz
40A DPDT
14
Yes
GM40E-M-240
240VAC, 50/60Hz
40A DPDT
20
Yes
20
Yes
40A DPDT
277VAC, 60Hz
GM40E-M-277
24-Hour/7-Day Electronic, DPDT, Mechanism Only w/Automatic Daylight Saving
Adjustment
GM40E42-M-120
120VAC, 50/60Hz
40A DPDT
42
Yes
GM40E42-M-240
240VAC, 50/60Hz
40A DPDT
42
Yes
GM40E42-M-277
277VAC, 60Hz
40A DPDT
42
Yes
SPECIFIERS GUIDE
Furnish and install a Grasslin GM40E ___ electronic time switch. This DPDT controller shall have
24 hour and 7 day programming and include block programs for different weekday schedules.
The LCD shall display time of day in AM/PM format and provide load status indication. A daylight
time adjustment key shall also be provided. The time switch will be programmable to the minute
and also offer a manual override for ON or OFF to the next scheduled event or for permanent
ON/AUTO/OFF. The DPDT relay output will be rated for 40A, 2HP @ 277VAC. Carry -over shall be
provided for a minimum of 7 days with a built -in rechargeable battery which need not be
replaced. Enclosure to be NEMA3R raintight.
8
Covered by U.S. Patent #6,563,237
C.E.C Certified Title 24, Par t 6 on all GM40E42 Models
File #E83486 1 Year Warranty
FEATURES
• 40 Amp. Rating
• Rechargeable battery backup
• SPDT and DPDT A-LINL-ONE !
• NEMA 3R Outdoor Enclosure is Standard
• No Tools Required—Guts Snap Easily Into
Intermatic Enclosure.
• Power and Status LED Indicators
• GM40E42 Models have automatic Daylight
Saving Time adjustment
• Ground Lug
GM40E Wiring Diagrams
Typical Wiring Diagram (120VAC Application)
TIMER
T
L1
L2/N
NC
NO
NC2
COM
NO2
COM2
LOAD
N
H
120VAC
Typical Wiring Diagram (240VAC Application)
TIMER
T
TL1
L2/N
NC
NO
COM
NC2
NO2
COM2
LOAD
L1
L2
240VAC
Typical Wiring Diagram (277VAC Application)
T
TIMER
T
L1
L2/N
N
H
277VAC
NC
NO
COM
LOAD
#1
www.grasslin.com
NC2
NO2
COM2
LOAD
#2
201-825-9696
Electronic Time Controls
GMX Digi Series
(24-Hour and/or 7-Day All-in-one)
General Purpose Time Switch
The GMX Digi Series Time Controls are universal, electronic time switches. They are a low cost
alternative for applications that do not require more than 16A. The unit is mounted in a NEMA
3R Outdoor enclosure..
APPLICATION: The GMX Digi is a light duty commercial time switch ideal for 24, 120, or 277 VAC
single phase applications such as:
• Lighting Control
• Access Control
• Heating, Air-Conditioning
• Agricultural Facilities
• Pumps/Motors/Fan Control
• General Electrical Circuits
ELECTRICAL RATINGS:
SPDT Contacts:
16A Resistive @ 120~250VAC
1,000W Tungsten @ 240VAC
WIRING CONNECTIONS:
Screw terminals accepts up to
12AWG wire
ENVIRONMENTAL RATINGS:
Operating Temperature Range:
–20°F to 140°F (–28.9°C to 60°C)
Operating Humidity: 0 to 95%
non-condensing
ENCLOSURE DIMENSIONS:
10” x 6.50” x 3.75” (H x W x D)
SHIPPING WEIGHT: 2 lbs.
ELECTRICAL LIFE:
6,000 Operations at Full Load
SWITCH CONFIGURATION:
SPDT (1-N.O. and 1-N.C. Contacts)
BATTERY BACKUP OPTION: 7 Days
SPECIFIERS GUIDE
Furnish and install a Grasslin GMX digi ___ 120 (24, 240, 277) volt electronic time
switch. This one (two) channel control shall have 24 hour and 7 day programming and include block programs for different weekday schedules. The LCD
shall display time of day in AM/PM format and provide load status indication. A
daylight time adjustment key shall also be provided. The time switch will be programmable to the minute and also offer a manual override for ON or OFF to the
next scheduled event or for permanent ON/AUTO/OFF. The SPDT relay output
will be rated for 16A @ 240VAC. Carry-over shall be provided for a minimum of
7 days with a built-in rechargeable battery which need not be replaced.
Enclosure to be NEMA 1 (NEMA 3R raintight).
C.E.C Certified Title 24, Par t 6 on all GMX Digi42 Models
File #E83486
1 Year Warranty
FEATURES
•
•
•
•
•
•
•
16 Amp. Rating
NEMA 1 Indoor or 3R Outdoor Enclosure
SPDT
24-Hour/7-Day Electronic w/Battery Backup
GMX Digi42 has automatic Daylight Saving Time adjustment
Finger safe terminals
Enclosure provides space for field added contactor or
other accessories
GMX Digi 42 Wiring Diagram
Typical Wiring Diagram (120VAC Application)
Timer
T
1
2
H
N
3
COM
4
N.O.
5
N.C.
LOAD
120VAC
GMX Digi Series Ordering Data
Enclosure Options, Substitute the Following for “X”:
“I” = NEMA 1 Indoor Enclosure, “IC” = NEMA 1 Indoor Enclosure with Clear Cover,
“O” = NEMA 3R Outdoor Enclosure, “OC” = NEMA 3R Outdoor Enclosure with Clear Cover, “IM” = NEMA 1 Indoor Metal Enclosure
Model Code
Timer Voltage
Prog.
Switch
Amps
20
20
20
20
42
42
42
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
16
16
16
16
16
16
16
Model Code
Timer Voltage
Prog.
120V 50/60Hz
208/240V 50/60Hz
24V 50/60Hz
42
42
42
Switch
Amps
Note: 6V & 12VDC Models Available
GMXdigi20-”X”-120
GMXdigi20-”X”-240
GMXdigi20-”X”-24
GMXdigi20-”X”-277
GMXdigi42-”X”-120
GMXdigi42-”X”-240
GMXdigi42-”X”-24
120V 50/60Hz
208/240V 50/60Hz
24V 50/60Hz
277V 50/60Hz
120V 50/60Hz†
208/240V 50/60Hz†
24V 50/60Hz†
www.grasslin.com
201-825-9696
Two Channel
GMX2digi42-”X”-120
GMX2digi42-”X”-240
GMX2digi42-”X”-24
(2) SPDT
(2) SPDT
(2) SPDT
16
16
16
9
Defrost Controls
DTMV40 Series
Time Initiated, Temperature, Pressure or Time
Terminated Multi-Voltage Defrost Timers
Captive Trippers
Can’t Be Lost
Independently
Adjustable Trippers
Allow For Full or
Partial Defrost Cycles
on 15 Minute Intervals
New Compact
VALOX® NEMA 3R
Outdoor Enclosure
Replaces All Metal
Enclosures
Red and Green LED
Lights Indicate
Defrost or Run Cycle
Large Screw
Terminals for Easy Wiring
#8 AWG
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
DTMV40 replaces over 40 competitive models
Multi-Voltage field adjustable for 120, or 208/240VAC
Mounts in existing enclosures, no tools required
Box lug terminals
Defrost times settable on quarter hour with captive trippers
NEMA 3R outdoor enclosure
40 Amp, 2HP Rating
Moisture resistant conformal coating
LED indications for defrost and refrigeration cycles
Compact Valox outdoor NEMA 3R enclosure
Defrost cycles are programmed independently
“Real-time” clock for quick, easy and accurate setting
Covered by U.S. Patent #6,563,237
RoHS Compliant 2002/95/EC
File #E83486 2 Year Warranty
Easy Multi-Voltage
Field Adjustable
DIP Switch for
120 or 208/240 VAC
True Clock Face
NO TOOLS
REQUIRED!
Our “GUTS” simply snap
into existing enclosure
40 Amp Rated
Contacts
Moisture Resistant
Conformal Coated Board
Ground Lug Termination
SPECIFICATIONS:
Switch Rating:
40A Resistive @ 120VAC, 208~240VAC
2HP @ 208~240VAC; 1HP @ 120VAC
16FLA, 90LRA @ 120VAC
12FLA, 52LRA @ 240VAC
“F” TERMINAL:
30A Resistive @ 120~240VAC
1HP @ 120VAC; 2HP @ 208~240VAC
WIRING CONNECTIONS:
Screw box lug terminals.
ENVIRONMENTAL RATINGS:
Operating Temperature Range: –40°F to 131°F (–40°C to 55°C)
Operating Humidity: 0 to 95% non-condensing
ELECTRICAL LIFE:
50,000 Operations at Full Load
DIMENSIONS:
8.795” x 6.631” x 2.935” (H x W x D)
SHIPPING WEIGHT: 3 lbs.
SPECIFIERS GUIDE
Furnish and install a Grasslin DTMV40 defrost control which is field adjustable for 120V or 240V operation and shall have defrost initiation times settable to the quarter hour via captive trippers at 15 minute intervals. The defrost timer shall be housed in a NEMA 3R indoor/ outdoor plastic enclosure. The relay output will be rated
for 40A Resistive, 2HP @ 250VAC. Defrost termination to be by time (and by a remote temperature or pressure switch).
10
www.grasslin.com
201-825-9696
THERMOSTAT
L1
L1
DEFROST
HEATER
LINE
TERMINATION
THERMOSTAT
W/FAN DELAY
FAN
MOTOR
240V
COMPRESSOR
OR
SOLENOID VALVE
OR
CONTACTOR COIL
120V
THERMOSTAT
TERMINATION
THERMOSTAT
W/FAN DELAY
DEFROST
HEATER
FAN
TIMER
N
L2
L2
F
COMPRESSOR
OR
SOLENOID VALVE
OR
CONTACTOR COIL
L1
1
2
3
4
N
X
Defrost
Controls
THERMOSTAT
am
DTMV Time/Temp.–Hot Gas Defrost Wiring Diagram
DTMV40
Time/Time–Electric or Air
8143
Replacement
S1 Position B with 8143
Label Applied
Diagram
Wiring
8
9
TIMER
RELEASE
RELAY
TIMER
1
N
F
L1
LINE
TERMINATION
THERMOSTAT
W/FAN DELAY
3
3
2
4
1-N
2
L1
HOT
FAN
LINE
L2
TIMER
RELEASE
RELAY
8143
LABEL
X
4
1
X
CONNECT ACROSS
COMPRESSOR
COMPRESSOR
OR
SOLENOID VALVE
THERMOSTAT
DEFROST
OR
HEATER
CONTACTOR COIL
3
N
4
2
8143
LABEL
X
L1
TERMINATION
THERMOSTAT
W/FAN DELAY
THERMOSTAT
GAS
VALVE
TIMER
TIMER
F
1
3
2
4
N
HI-LO PRESSURE SW.
SOLENOID
VALVE
OR
CONTACTOR
DEFROST
HEATER
LINE
TERMINATION
THERMOSTAT
L2
L2NOTE: Remove Bridge Between 3–4
DEFROST
HEATER
COMPRESSOR
OR
SOLENOID VALVE
OR
CONTACTOR COIL
FAN
MOTOR
TERMINATION
THERMOSTAT
W/FAN DELAY
L2
NOTE: Remove Bridge Between 3–4
NOTE: Connect Bridge Between 2–X
*See Note 1
X
THERMOSTAT
L1
LINE
8141
LABEL
FAN
MOTOR
DTMV40 Time/Temperature–Electric
Defrost Wiring Diagram
TIMER
RELEASE
RELAY
TIMER
RELEASE
RELAY
TIMER
L2
DTMV40
Time/Temperature–Electric
DTMV
Time/T
emp.–Electric Defrost Wiring Diagram
8143 Defrost
Replacement–Double
Pole Switching
Wiring Diagram
S1 Position B with 8143 Label Applied
Defrost
COMPRESSOR
OR
SOLENOID VALVE
OR
CONTACTOR COIL
DEFROST
HEATER
LINE
NOTE: Fan motor may be connected to “F” terminal instead of “4” terminal if desired.
g Diagram
DTMV Time/Pressure–Compressor Shutdown
8243 Replacement
S1 Position B with Trippers Reversed
11
DTMV Time/Pressure–Electric Defrost Wiring Diagram
8247 Replacement–Double Pole Switching
S1 Position B with 8247 Label Applied
12
Mechanism Only
MER
EASE
LAY
8245
LABEL
2
3
F
DTMV40-M
1-N
TIMER
RELEASE
RELAY
TIMER
4
Xp
p
8243
LABEL
3
2
4
DTMV40-B
N
1
L1
PRESSURE
SWITCH
LINE
Xp
p
8247
LABEL
L1
PRESSURE
SWITCH
COMPRESSOR
Fits Into
L2
Competitors
NOTE: Remove Bridge Between 1-N –2
Enclosure
*See Note 2
LINE
p
Bracket Mount
TIMER
RELEASE
RELAY
TIMER
L2
• All-in-one Assembly
DEFROST
• Identical
Footprint as Paragon
(-20B)
HEATER
PRESSURE
SWITCH
• High Impact Polystyrene
Material
NOTE:
Bridge
Between
3–4Rated
• Remove
UL94HB
Flame
Class
NOTE: Connect Bridge Between 4–Xp
• Electrically Isolated
SOLENOID
VALVE
OR
CONTACTOR
Universal Replacement
DTMV40
=
* Recommended Pressure Switches:
Johnson/Penn P170, Ranco 010 series, or
Danfoss KP1 series. Pressure range
approximately 35-110psi, Cut-in on
pressure rise.
PARAGON
PRECISION
8141-00
8143-00
8145-00
8041-00
8043-00
8045-00
8046-00
8047-00
8141-20
8143-20
8145-20
8041-20
8043-20
8045-20
8046-20
8047-20
8245-20*
8243-20*
8247-20*
6141-00
6143-00
6145-00
6041-00
6043-00
6045-00
6047-00
6141-20
6143-20
6145-20
6041-20
6043-20
6045-20
NO TOOLS REQUIRED!
Simply snaps into existing enclosure.
Wiring is identical—no need to change.
6047-20
6245-20
6243-20
6247-20
DTMV40 Series Ordering Data
Time Initiated, Remote Temperature, Pressure, or Time Terminated
Timer Type
Battery
Backup
Duration
DTMV40
DTMV40-M
DTMV40-B
DTMV40-P
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
NEMA 3R Outdoor Enclosure
Mechanism Only
Bracket Mount
Panel Mount
Synchronous
Synchronous
Synchronous
Synchronous
N/A
N/A
N/A
N/A
1 to 24
1 to 24
1 to 24
1 to 24
15-180 min.
15-180 min.
15-180 min.
15-180 min.
15 min.
15 min.
15 min.
15 min.
DTQMV40
DTQMV40-M
DTQMV40-B
DTQMV40-P
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
120V, 208/240V, 60Hz
NEMA 3R Outdoor Enclosure
Mechanism Only
Bracket Mount
Panel Mount
Quartz
Quartz
Quartz
Quartz
1 week
1 week
1 week
1 week
1 to 24
1 to 24
1 to 24
1 to 24
15-180 min.
15-180 min.
15-180 min.
15-180 min.
15 min.
15 min.
15 min.
15 min.
120V, 50/60Hz
208/240V, 50/60Hz
NEMA 3R Outdoor Enclosure
NEMA 3R Outdoor Enclosure
Electronic*
Electronic*
1 week
1 week
1 to 8
1 to 8
1-180 min.
1-180 min.
1 min.
1 min.
Model Code
DT140 Digi 20-120
DT140 Digi 20-240
*Rated aty 30 Amps
Voltage
www.grasslin.com
Mounting
201-825-9696
Defrost
Frequency
No./Day
Defrost
Duration
Minimum
Duration
Interval
11
Single Channel Electronic Time Controls
Digi 20 and Digi 42 Series
24 Hour and/or 7 Day
APPLICATION: Time based control of lighting, ventilating, heating, cooling or other electrical loads in commercial and industrial applications. These one channel time switches
are programmable for 24-hour or 7-day schedules. The Digi 42 offers an “8th day” or holiday schedule. The Digi 20A or Digi 42A are intended for either surface or DIN rail mounting. Both models are completely enclosed in a plastic housing and includes a terminal
cover and sub-base for installation and hard wiring. The Digi 20E or Digi 42E are intended for flush mounting. Both models are supplied with a clear plastic snap-on dust cover.
SPECIFICATIONS
Digi 20
Digi 42
Channels
Programs
Holiday Program
Reserve Carryover; min.
Automatic Spring/Fall Daylight Saving
Time Changeover
1
20
No
1 week
1
42
Yes
2 weeks
No
Yes
File #E83486
Digi 42A
C.E.C. CERTIFIED TITLE 24,
PART 6 ON ALL DIGI 42 MODELS
TECHNICAL DATA
OUTPUT: 1 SPDT relay with dry contacts
SWITCHING CAPACITY: 16A Resistive @ 277VAC
1000W Tungsten @ 240VAC
INPUT DRAW: 4VA
SHORTEST SWITCHING TIME: 1 minute
ACCURACY: Less than ±4 minutes per year deviation
AMBIENT TEMPERATURE: 0°F to 140°F (–18°C to 60°C)
AMBIENT HUMIDITY: 0 to 95% RH, non-condensing
Selectable AM/PM or 24 hr. (military) time LCD display
One Key Daylight Time Changeover (automatic on Digi 42)
MANUAL 3-WAY OVERRIDE: Temporary or permanent ON or
OFF status indication in LCD display.
WIRING CONNECTIONS:
“A” Models: screw terminals for
#10 to #24 AWG wire
“E” Models: 1/4” quick connects
FEATURES
•
•
•
•
•
•
•
•
•
Digi 20E
24 hour or 7 day programming with accuracy to the second
Easy programming; minimal keys and programming steps
Unique “Circular Programming” with large keys is easier to use
Selectable blocks of weekdays or weekends for quick programming on
Digi 20, any combination of days on Digi 42
Holiday program on Digi 42 may be scheduled a week in advance for
one or more days
Rechargeable battery backup with 1-4 weeks reserve carry-over
Manual override provides for either temporary or continuous ON or OFF
state, with status displayed in large LCD
Digi 42 models have automatic Daylight Saving Time changeover
24V models will operate either on AC or DC
Digi 20 or Digi 42 Wiring Diagram
SPECIFIERS GUIDE
Furnish and install a Grasslin Digi 20 (Digi 42) ___ electronic time switch. This 1 channel control shall
have 24 hour and 7 day programming and also offer 10 (21) ON and 10 (21) OFF setpoint programs
and include 4 block programs (allow selection of any combination of days) for different weekday
schedules. The LCD shall display time of day in AM/PM or military time format and provide load status indication. A Daylight Saving Time adjustment key shall also be provided. The time switch will be
programmable to the minute and also offer a manual override for ON or OFF to the next scheduled
event or for permanent ON/OFF/Automatic. (The Digi 42 shall provide a 8th day or “Holiday” program
which may be activated to begin on a specific day up to a week in advance, and continue from 1 to
99 days, selectable by the user.) The SPDT relay output will be rated for 16A Resistive @ 277VAC.
Reserve shall be provided for a minimum of 7 days with built-in rechargeable batteries which need
not be replaced. The time switch shall be surface, DIN rail or flush mountable or shall be available
with a NEMA 1 indoor or NEMA 3R outdoor enclosure.
Typical Wiring Diagram (120VAC Application)
Timer
T
1
2
H
N
3
COM
4
N.O.
5
N.C.
LOAD
120VAC
Digi 20 and Digi 42 Series Ordering Data — Digi 42A and E also available for 12VDC input.
Model Code
Digi20A – 120
Digi20A – 240
Digi20A – 24
Digi20A – 277
Digi42A – 120
Digi42A – 240
Digi42A – 24
Digi20E – 120
Digi20E – 240
Digi20E – 24
Digi20E – 277
Digi42E – 120
Digi42E – 240
Digi42E – 24
Timer Voltage
Mounting
120V, 50/60Hz
208/240V, 50/60Hz
24V, 50/60Hz
277V, 50/60Hz
120V, 50/60Hz
208/240V, 50/60Hz
24V, 50/60Hz
120V, 50/60Hz
208/240V, 50/60Hz
24V, 50/60Hz
277V, 50/60Hz
120V, 50/60Hz
208/240V, 50/60Hz
24V, 50/60Hz
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
Flush Panel
Flush Panel
Flush Panel
Flush Panel
Flush Panel
Flush Panel
Flush Panel
Setpoint
Programs
20
20
20
20
42
42
42
20
20
20
20
42
42
42
Maximum Weekly
On/Off Events
Relay Output
Resistive Rating
140
140
140
140
294
294
294
140
140
140
140
294
294
294
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
SPDT, 16A, 250V
(24V models will operate on AC or DC)
12
www.grasslin.com
201-825-9696
Dual Channel Electronic Time Controls
Digi 42/2
24 Hour and/or 7 Day
APPLICATION: This unit can be used to control 240VAC two-phase loads such as pumps,
compressors, etc. It can also be used to provide time based control of two circuit lighting, ventilating, heating, cooling or other electrical loads in commercial and industrial
applications. The Digi 42/2 time switches are programmable for 24-hour or 7-day schedules as well as an “8th day” or holiday schedule. Each channel can operate independently or combined.
SPECIFICATIONS
OUTPUT SWITCHES: Two SPDT relays with dry contacts
SWITCH CAPACITY: 16A General Purpose, 125-250VAC
1000W Tungsten, 250V
500W Tungsten, 125V
N.O. Contact:
1HP, 240VAC; 1/2HP, 120VAC
Pilot Duty: 720VA, 120-240VAC
3/4HP, 240VAC; 1/3HP, 120VAC
N.C. Contact:
Pilot Duty: 360VA, 120-240VAC
INPUT POWER: 4.4VA
SHORTEST SWITCHING TIME: 1 minute
ACCURACY: Less than ±4 minutes per year deviation
AMBIENT TEMPERATURE: 0°F to 140°F (–18°C to 60°C)
AMBIENT HUMIDITY: 0 to 95% RH, non-condensing
Selectable AM/PM or 24 hr. (military) time display
Selectable completely automatic or one key manual daylight time
changeover
MANUAL 3-WAY OVERRIDE: Temporary or permanent ON or OFF; status
indication in LCD display
WIRING CONNECTIONS: Screw terminals #12 to #24AWG
SIZE: 2.83” x 2.83” square face, x 2.28” deep
UL AND CANADIAN UL RECOGNIZED: File E83486
File #E83486
C.E.C. CERTIFIED TITLE 24,
PART 6 ON ALL DIGI 42/2 MODELS
FEATURES
• 24 hour or 7 day programming with resolution to the minute and accuracy to the second
• Large keys ease programming
• Unique circular programming pattern and minimal steps simplify programming
• Automatic Daylight Saving Time changeover in spring and fall eliminates
need to manually change the time
• Holiday, or “8th day” program may be scheduled a week in advance for
one or more days
• Each channel may be programmed separately, or both together
• Automatically recharged NiCad battery maintains program and display
for two weeks or more
• Manual override for each channel provides for either temporary or continuous ON or OFF state, with status displayed in large LCD
Digi 20 or Digi 42 Wiring Diagram
SPECIFIERS GUIDE
Furnish and install a Grasslin Digi 42/2 electronic time switch. This two channel control shall have
24 hour and 7 day programming and also offer 21 ON and 21 OFF setpoint programs and allow
selection of any combination of days for different weekday schedules. The LCD shall display time of
day in AM/PM or military time format and provide load status indication. Selectable automatic or
manual daylight time changeover shall be provided. In automatic mode, the time switch shall automatically advance the time by 1 hour at 2AM on the first Sunday of April, and set back the time 1
hour at 2AM on the last Sunday of October. The time switch shall be programmable to the minute
and also offer a manual override for ON or OFF to the next scheduled event or for permanent
ON/OFF/Auto. A 8th day or “Holiday” program shall be provided which may be activated to begin on
a specific day up to a week in advance, and continue from 1 to 99 days, selectable by the user. The
SPDT relay outputs will be rated for 16A General Purpose, 1HP at 240V, and 16A General Purpose,
1/2HP at 120V as well as pilot duty of 720VA. Reserve shall be provided for a minimum of 14 days
with a built-in rechargeable battery which need not be replaced. The time switch shall be surface or
flush panel mountable with a DIN rail mounting base optional, or shall be available with a NEMA 1
indoor or NEMA 3R outdoor enclosure.
Typical Wiring Diagram (240VAC Application)
TIMER
T
1
2
3
4
5
6
7
8
LOAD
L1
L2
240VAC
Digi 42/2 Ordering Data
Model Code
Timer Voltage
Mounting*
Digi42/2 – 120
Digi42/2 – 240
Digi42/2 – 24
120V, 50/60Hz
240V, 50/60Hz
24V, 50/60Hz
Flush or Surface
Flush or Surface
Flush or Surface
Setpoint
Programs
42
42
42
Maximum Weekly
On/Off Events
Relay Output
General Purpose Rating
294
294
294
(2) SPDT, 16A, 250VAC
(2) SPDT, 16A, 250VAC
(2) SPDT, 16A, 250VAC
*For DIN rail mounting, order: MB-DIN Rail Mounting Base
www.grasslin.com
201-825-9696
13
Advanced Electronic Time Controls 1, 2, and 4 Channels
Talento 400 & 800 Series
24 Hour, 7 Day, 365 Day Multi-Function Time Controls
APPLICATION: The Talento series electronic time switches provide time-of-day control
for lighting, heating, air conditioning, pumps, motors or general electrical circuits. The
“400” series are 24-hour/7-day controls, while the “800” series units offer 365-day
programming with holiday capability through the year 2095. All models offer automatic leap year and daylight savings adjustment. These features are activated when
the user enters the current date and respective Daylight Saving Time change-over
dates. From that point on, daylight change-over dates will never have to be entered
again. A LCD indicates the load status, time-of-day, weekday and on the “800” series,
the date. The units can be surface mounted, mounted to a standard DIN rail or within a Grasslin enclosure for stand-alone installations. Enclosure options include indoor
or outdoor plastic (with solid or clear cover) or indoor metallic. In addition to the conventional ON/OFF programming format, these units offer pulse and cycle functions. A
pulse is simply an ON or OFF event with a duration of one or more seconds. The cycle
function provides for a repeating ON event within a selectable total cycle. Both the ON
duration and the total cycle duration are independently programmable in minutes or
seconds. In addition, the cycle function can be set to repeat indefinitely or to occur
within a time and/or date range.
Talento 400 & 800 Series Cycle Programming
Start Time
End Time
On
Off
“On”
“Total”
The “On” and “Total” time are independently
programmable in minutes or seconds
Talento 800 Dimensions
File #E83486
FEATURES
• 1, 2 & 4 channels programmable
independently or simultaneously
• Automatic leap year and daylight
saving time adjustment
• Pulse programming for school bells, sirens, or
lighting contactor applications
• Cycle programming for pump or other
sequencing applications
• Lithium battery backup keeps clock running
• EEPROM Non-Volatile program memory
• Astronomical function on Talento 800 series
(Requires Software)
SPECIFIERS GUIDE
800 Series: The contractor shall furnish and install a Grasslin talento 894, 4 channel (892, 2 channel / 891, 1 channel) electronic time switch. Each channel shall be independently programmable. A total of 400 events shall be provided. The time switch shall offer daily, weekly or annual programming capability with up to 99 separate holiday periods of any duration and priority. Three types of switching commands shall be provided; on/off, pulse and cycle. Automatic or user selectable Daylight Saving
Time change-over shall be incorporated through the year 2095. An optional Windows ®-based software program shall be available for remote programming capability.
It shall provide full graphic indication of the switching schedule. It shall also include a database of fixed and floating holidays. Floating holidays will automatically repeat
each year on the correct date. An astronomical program shall be included which will automatically adjust the switch event schedule according to the changing sunrise
and sunset times. A LCD shall be provided to indicate the current time, date, switch contact status and program schedule. A replaceable lithium battery shall be provided to maintain the current time and date in the event of a power failure for up to six (6) years; the switch program shall be stored in non-volatile (EEPROM) memory. The
SPDT switch contacts shall be rated for 16A at 250VAC. Time switch supply voltage shall be 24VAC/DC or 120VAC or 240VAC. The time switch shall be capable of surface
or DIN rail mounting or it can be provided in an indoor or outdoor (NEMA 1 or 3R) enclosure. It shall be UL, C-UL recognized, and UL/C-UL listed in optional enclosure.
400 Series: The contractor shall furnish and install a Grasslin talento 472, 2 channel (471, 1 channel) electronic time switch. Each channel shall be independently programmable. A total of 40 (30, 471) events shall be provided. The time switch shall offer daily or weekly programming. Three types of switching commands shall be provided; on/off, pulse and cycle. Automatic or user selectable Daylight Saving Time change-over shall be incorporated through the year 2095. A LCD shall be provided to
indicate the current time, day, switch contact status and program schedule. A lithium battery shall be provided to maintain the current time and date in the event of a
power failure for up to three (3) years; the switch program shall be stored in non-volatile (EEPROM) memory. The SPDT switch contacts shall be rated for 16A at 250 VAC.
Time switch supply voltage shall be 24VAC/DC or 120VAC, or 240VAC. The time switch shall be capable of surface or DIN rail mounting or it can be provided in an indoor
or outdoor (NEMA 1 or 3R) enclosure. It shall be UL, C-UL recognized, and UL/C-UL listed in optional enclosure.
Remote PC Programming
The talento 800 series can be programmed from a PC utilizing the optional talento dialog set. The set
includes Windows®-based software, the taxxi hand-held programmer, CD Rom, interconnect cable
and instructions.
The software contains a schedule of fixed and floating holidays that can be selected, as required, for
the particular application. Floating holidays will automatically repeat on the correct date, year after
year. Thus, all fixed and floating holidays need only be programmed once. In addition, an astronomical
program is included which will automatically adjust the program schedule to follow the changing sunrise and sunset times.
Once the programming is completed on the PC, it is transferred to the taxxi hand programmer from
which programs are downloaded into one or more installed talento 800 series time controls. The taxxi
can store up to four independent programs and can also upload a program from the talento into a
PC for review or editing.
14
www.grasslin.com
201-825-9696
Advanced Electronic Time Controls 1, 2, and 4 Channels
Talento 400/800 Series Ordering Data
SPECIFICATIONS
Talento 800 Series
Input Voltage: 24VAC/VDC, 120VAC, 50/60 Hz
Output Rating: 16A Resistive @ 250VAC per channel
Output Configuration: SPDT dry contacts for each channel
POWER CONSUMPTION: 5 VA
BATTERY BACKUP: 6 years, replaceable
TEMPERATURE RANGE: –13°F to 131°F (–25°C to 55°C)
DISPLAY: AM/PM or Military LCD 1" x 1-11/16"
WEIGHT: 18 oz.
MOUNTING: Surface & DIN rail (NEMA 1 indoor & NEMA 3R
outdoor enclosures available)
SHORTEST SWITCHING TIME: One second
MODEL
VOLTAGE
Mechanism Only
Talento 471-24
24VAC/DC, 50/60Hz
Talento 471-120
120VAC, 50/60Hz
24VAC/DC, 50/60Hz
Talento 891-24
120VAC, 50/60Hz
Talento 891-120
Talento 472-24
24VAC/DC, 50/60Hz
Talento 472-120
120VAC, 50/60Hz
Talento 892-24
24VAC/DC, 50/60Hz
120VAC, 50/60Hz
Talento 892-120
24VAC/DC, 50/60Hz
Talento 894-24
Talento 894-120
120VAC, 50/60Hz
NEMA 1 Indoor Enclosure
GMX 471-I-24
24VAC/DC, 50/60Hz
120VAC, 50/60Hz
GMX 471-I-120
24VAC/DC, 50/60Hz
GMX 891-I-24
GMX 891-I-120
120VAC, 50/60Hz
GMX 472-I-24
24VAC/DC, 50/60Hz
120VAC, 50/60Hz
GMX 472-I-120
24VAC/DC, 50/60Hz
GMX 892-I-24
120VAC, 50/60Hz
GMX 892-I-120
GMX 894-I-24
24VAC/DC, 50/60Hz
GMX 894-I-120
120VAC, 50/60Hz
Talento 400 Series
Input Voltage: 24VAC/VDC, 120VAC, 50/60 Hz
Output Rating: 16A Resistive @ 250VAC per channel
Output Configuration: SPDT dry contacts for each channel
POWER CONSUMPTION: 5 VA
BATTERY BACKUP: 3 years
TEMPERATURE RANGE: –13°F to 131°F (–25°C to 55°C)
DISPLAY: AM/PM or Military LCD 5/8" x 13/16"
WEIGHT: 5.5 oz.
MOUNTING: Surface & DIN rail (NEMA 1 indoor & NEMA 3R
outdoor enclosures available)
SHORTEST SWITCHING TIME: One second
OUTPUT
CHANNELS
PROGRAMS
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
1
1
1
1
2
2
2
2
4
4
30
30
400
400
30
30
400
400
400
400
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
16A SPDT
1
1
1
1
2
2
2
2
4
4
30
30
400
400
30
30
400
400
400
400
Talento 400 and 800 Terminal Connections
talento 472
talento 471
CH 1
CH 2
M
~
1
CH 3
CH 4
M
~
2
3
INPUT NO
4
5
6
NC NO
7
CH 1
CH 2
8 1 9 2 10
113
12
4 13
5
146
7
8
9
NC NO
10
11
12 13
NC NO
14 1
CH 1
CH 3 CHCH
1 4 CH 2
M
~
NCINPUT
NO NC
NO NONC NC
NO
talento 894
talento 892
talento 891
CH 3 CHCH
1 4 CH 2
CH 3
CH 2
CH 3
CH 4
M
~
CH 4
M
~
2
3
NC
INPUT NO
4
5
6
NC NO
7
8
1 9 2 10
113
12
4 13
5
146
7
8
NCINPUT
NO NC
NONONC NC
NO
9
NC NO
10
11
12 13
NC NO
14
1
2
NCINPUT
3
NO
4
5
6
NC NO
7
8
9
NC NO
10
11
12 13
NC NO
14
NC
SRS 3800
7 Day, 8-Channel End Time Switches
APPLICATION: Time of day ON/OFF control of 8 circuits of HVAC systems,
zone heating, industrial processes, alarm systems, lighting, fans, pumps or
other loads in commercial, industrial, institutional, and agricultural facilities.
A simple and effective energy management system for small and mid-sized
office buildings, schools, banks, malls, and government buildings.
FEATURES
• 8 channels programmable independently or simultaneously
• 7 day programming
• 2 ON and 2 OFF settings per day
• ON-OFF-AUTO Override for each channel
• Holiday “OFF” provision
• Indoor/Outdoor enclosure w/clear door
• Battery backup for 1 month
• 10 Amp, SPDT switching
SRS 3800 Wiring Diagram
SPECIFICATIONS
INPUT VOLTAGE: 120VAC 50/60 Hz
OUTPUT RATING: 10A Resistive @ 120~240VAC per channel
OUTPUT CONFIGURATION: 6 SPDT, 2 SPST (NO)
POWER CONSUMPTION: 12VA
SHORTEST SWITCHING TIME: 1 minute
AMBIENT TEMPERATURE: 14°F to 122°F (–10°C to 50°C)
AMBIENT HUMIDITY: 0 to 95% RH, non-condensing
MANUAL 3-WAY OVERRIDE: Auto-On-Off
“ON” or “OFF” status indicator for each channel
WIRING CONNECTIONS: Screw terminals, 12-24AWG
SIZE: 8.38 (213mm) x 7.08” (180mm) x 4.5” (114mm)
SRS 3800 Ordering Data
MODEL
VOLTAGE
Plastic Clear Enclosure
120VAC, 60Hz
SRS3800-120
www.grasslin.com
201-825-9696
OUTPUT
CHANNELS
PROGRAMS
10A, 6-SPDT & 2-SPST
8
224
15
Electromechanical Timer Modules
FM/1 Series
24 Hour, 7 Day
APPLICATION: The FM/1 series electromechanical timer modules are designed to be placed inside a
machine control panel, circuit board, or other equipment. It offers up to 21A switching designed for control of heating, ventilating, air conditioning, refrigeration, lighting, security, circulating pumps, spas or any
electrical load requiring 24-hour or 7-day scheduling.
SPECIFICATIONS
SIZE: 2.36” x 2.36” x 1.25”
SUPPLY VOLTAGE: 24, 120, 240VAC
POWER CONSUMPTION: 1VA
SWITCH RATING: SPDT
Resistive: 21A
Tungsten: 1350W
Inductive: 1HP @ 120VAC
2HP @ 240VAC
WIRING CONNECTIONS: 1/4” quickconnects
INSTALLATION:
Stand Alone: With indoor or outdoor
enclosure
Panel: Surface mounting
FM/1 Wiring Diagram
File #LR52379
File #E83486
C
FEATURES
•
•
•
•
21A SPDT switch
Captive Trippers
1/4” quick terminals
Noise Immune—Ideal for
robust applications
FM/1 Series Ordering Data†
Switch
Program
Carry-Over
Program
On/Off Every
Minimum
On/Off Time
Switch Output
Type
Rating
FM/1 STuZ (synchronous)
FM/1 SWuZ (synchronous)
24 hr.
7 day
No
No
15 minutes
2 hours
15 minutes
2 hours
SPDT
SPDT
21A Res.
21A Res.
FM/1 QTuZ (quartz)
FM/1 QWuZ (quartz) 7 day
24 hr.
7 day
7 day
2 hours
15 minutes
2 hours
15 minutes
SPDT
SPDT
21A Res.
21A Res.
†For 3-way override switch: Add “H”
Available with 24V, 120V, 240V, 277VAC input
KM2 Series
24 Hour, 7 Day
APPLICATION: The KM/2 series modules are
designed to fit into tight locations. It offers up to
21A switching designed for control of heating, ventilating, air conditioning, refrigeration, lighting,
security, circulating pumps, spas or any electrical
load requiring 24-hour or 7- day scheduling.
FEATURES
•
•
•
•
Very small and compact, fits anywhere
On/Auto/Off manual switch standard
Captive trippers for easy programming
1/4” quick terminals
SPECIFICATIONS
SIZE: 1.67” x 2.64” x 1.67”
POWER CONSUMPTION: 1VA
SWITCH RATING: SPDT
Resistive: 21A @ 250V
1HP @ 125VAC
Motor:
2HP @ 250VAC
Inductive: 8A @ 250VAC
Tungsten: 1350W
WIRING CONNECTIONS: 1/4” quickconnects
KM2 Wiring Diagram
File #E83486
File #LR52379
C
KM2 Series Ordering Data
OPERATING FEATURES
Switch Program
KM2 STuH
KM2 SWuH
16
24 hr.
7 day
Program On/Off Every
20 minutes
2 hr. 20 minutes
Switch Output
Minimum On/Off Time
20 minutes
2 hr. 20 minutes
Type
SPDT
SPDT
www.grasslin.com
Rating
21A Res.
21A Res.
201-825-9696
Electronic Timer Modules
2.36” 60mm
FM/1 digi 20 24 Hour and/or 7 Day
FEATURES
FM/1 digi 20 Wiring Diagram
• 20 programs, up to 140
events per week
• Easy to program with
large keys
• 16 Amp @ 277V SPDT
switching
• Capacitor backup with 5
day carryover
• Manual override
2.44” 62mm
SPECIFICATIONS
SWITCH RATING: SPDT
16A Resistive @ 277VAC
1000W Tungsten @ 240VAC
INPUT DRAW: 4VA
INPUT FREQUENCY: 50/60Hz
SHORTEST SWITCHING TIME: 1 minute
AMBIENT TEMPERATURE: 0°F to 140°F (–18°C to 60°C)
AMBIENT HUMIDITY: 0 to 95% RH, non-condensing
WIRING CONNECTIONS: 1/4” quick connects
UL and Canadian UL File E 83486
2.12” 54mm
File #E83486
FM/1 digi 14
24 Hour and/or 7 Day
FM/1 digi 14 Wiring Diagram
SPECIFICATIONS
WIRING CONNECTION: 1/4” Quick Terminals
SUPPLY VOLTAGE: 125VAC, 60 Hz.
SWITCH OUTPUT: SPDT (Form C Relay Contacts)
Switch Rating: 15A General Purpose/Resistive @125VAC
1000W Tungsten @125VAC
1/2HP @125VAC
BATTERY BACK-UP: Rechargeable Ni-MH (Holds program
and keeps time for up to 60 days)
OPERATING TEMPERATURE: –10°C to + 55°C
ACCURACY: ± 1 sec/day at 20°C
NUMBER OF PROGRAMS: 7 ON, 7 OFF
BLOCK PROGRAMMING: MON-SUN, MON-FRI, SAT-SUN,
MON-SAT, MON-WED-FRI
SHORTEST SWITCHING TIME: 1 Minute
DISPLAY: Backlit LCD (Illuminates in the dark)
PROTECTION: MOV and Thermal Fuse
APPROVALS: UL &cUL
FM/1 Digi 14
File #E149422
M
COM
1
2
3
NO
4
FEATURES
NC
5
• Integrated MOV surge
protection assures reliable operation
• Thermal fuse protects unit in the event of overload
• 1/4” quick terminals for easy wiring connection
• Rechargeable Ni-MH battery holds program and
keeps time for up to 60 days
• Block programming reduces number of events:
MON-SUN, MON-FRI, SAT-SUN, MON-SAT, MONWED-FRI
• Backlit LCD illuminates in the dark
• 14 programs for maximum 98 weekly ON/OFF
events
LOAD
120VAC
HOT
NEUTRAL
FM/1 digi 42 24 Hour and/or 7 Day
SPECIFICATIONS
SWITCH RATING: SPDT
16A Resistive @ 277VAC
1000W Tungsten @ 240VAC
INPUT DRAW: 4VA
INPUT FREQUENCY: 50/60Hz
SHORTEST SWITCHING TIME: 1 minute
AMBIENT TEMPERATURE: 0°F to 140°F (–18°C to 60°C)
AMBIENT HUMIDITY: 0 to 95% RH, non-condensing
WIRING CONNECTIONS: 1/4” quick connects
UL and Canadian UL File E 83486
FEATURES
• Automatic Daylight Saving Time
Changeover
• 42 programs, up to 294 events per
week
• Holiday programming
• 16 Amp @ 277V SPDT switching
• Rechargeable battery backup with carryover of over 4 weeks
C.E.C Certified Title 24, Par t 6 on
all Digi 42 Models
File #E83486
FM/1 Series Ordering Data – FM/1 digi 42 also available for 12VDC input, 24V models are AC/DC.
Model
Input Voltage
FM/1 digi 14–120
FM/1 digi 20–120
FM/1 digi 20–240
FM/1 digi 20–24
FM/1 digi 20–277
FM/1 digi 42–120
FM/1 digi 42–240
FM/1 digi 42–24
120V 50/60Hz
120V 50/60Hz
240V 50/60Hz
24V 50/60Hz
277V 50/60Hz
120V 50/60Hz
240V 50/60Hz
24V 50/60Hz
www.grasslin.com
Switch
Program
Programs
Max. Weekly
On/Off Events
24 hr./7 day
24 hr./7 day
24 hr./7 day
24 hr./7 day
24 hr./7 day
14
20
20
20
20
98
140
140
140
140
24 hr./7 day
24 hr./7 day
24 hr./7 day
42
42
42
294
294
294
201-825-9696
Holiday
Program
Reserve
Carryover
Relay Output
No
No
No
No
No
60 days
1 week
1 week
1 week
1 week
SPDT 15A
SPDT 16A
SPDT 16A
SPDT 16A
SPDT 16A
Yes
Yes
Yes
2 weeks
2 weeks
2 weeks
SPDT 16A
SPDT 16A
SPDT 16A
17
In-Wall Mechanical Count Down Timer
KLT Series
Spring Wound Interval
Countdown Time Switch
KLT can be wired into new or existing standard wall box as a replacement to a toggle
switch. It provides temporary timed power to loads such as lighting, heat lamps,
exhaust fans, heaters, air conditioners, pumps, and other equipment. Spring operated
interval/countdown timer. Completely mechanical; does not require input power.
Automatically turns OFF the load at end of the time interval, saving energy and extending equipment life. May be used in Energy Management Systems as an override to temporarily turn loads ON that have been turned OFF by the system.
File #E13151
FEATURES
• Timing ranges from 5 minutes to 12 hours
• Heavy Duty 20A@125VAC SPST (N.O. and N.C.)
• SPST 20A, 1HP switch
• Decorator style dial plate fits both standard and
decorator wallplates
• Aluminum wallplate available
• Fits in single or multigang wallboxes
• May be flush panel mounted
• Normally open and closed standard connection
(except 5 min.)
• Hold models available
SPECIFICATIONS
SPST Switch Contact Ratings (50/60Hz):
20A@125VAC (Resistive/Inductive)
1HP@125VAC (Inductive)
7A@125VAC (Tungsten)
10A@250VAC (Resistive/Inductive)
10A@277VAC (Resistive/Inductive)
WIRING CONNECTIONS: Screw Terminals
OPERATING TEMPERATURE: –20°F to 185°F
N.O. and N.C. Terminals
SPECIFIERS GUIDE
Furnish and install a Grasslin ___ mechanical spring wound timer which requires no electricity to
operate the timing mechanism. The time switch must be capable of fitting a standard 2-1/2” deep
single or multigang wallbox and a decorator wallplate or standard toggle switch wallplate. Knob
and scaleplate shall be available in ivory (white) or with an aluminum wallplate and plastic knob.
The device must also be capable of flush panel mounting. The SPST switch shall close when manually activated and automatically open at the end of the time interval (units with “Hold” option will
remain permanently closed if the hold mode is selected). Normally closed versions shall open
when manually activated and automatically close at the end of the time interval. The switch contact shall be rated 20A (inductive).
KLT Series Ordering Data
Time Cycle
0-5 Minutes
0-15 Minutes
0-30 Minutes
0-60 Minutes
0-2 Hours
0-4 Hours
0-6 Hours
0-12 Hours
Example: KLT-30M-W
Example: KLT-30MH-A
18
No-Hold Models with IVORY Knob & Plate
Hold Models with IVORY Knob & Plate
KLT-5M
KLT-15M
KLT-30M
KLT-60M
KLT-2H
KLT-4H
KLT-6H
KLT-12H
Add “-W” to above for white knob & plate
Add “-A” to above for aluminum plate & plastic knob
KLT-5MH
KLT-15MH
KLT-30MH
KLT-60MH
KLT-2HH
KLT-4HH
KLT-6HH
KLT-12HH
www.grasslin.com
201-825-9696
In-Wall Electronic Count Down Timer
ET616
Electronic Interval Countdown Timer
The ET 616 is a wall mounted Electronic Time Switch which automatically turns lights
or other loads OFF after a preset time period. When used for control of lights in a conference room, rest room, or similar temporary use room, it functions like a standard
light switch, turning the lights ON when the button is pressed, and OFF when pressed
again. If left ON, it will automatically turn OFF after a time period settable from 5 minute
to 12 hours via tamper-proof dip switches. It is also suitable for the control of tanning
beds, fans, heaters, chemical pumps, laboratory apparatus, and other applications
requiring a preset ON time and automatic shutoff.
FEATURES
Green
Black
• Operates on 120V or 277VAC
File #E210523
• Mounts in standard wallbox
• Single button ON/OFF operation
• Backlighted LCD display
• Preset time adjustments; 5, 15, 30, 60 minutes, 3,
6, 9, 12 hours
• Switch holds position during a power failure (on
or off), restarts at preset time when power is
restored
Hot
• UL and cUL Listed
• Clamshell packaging available
277V Ground
Red
• Wall plate included
Green/Yellow
SPECIFICATIONS
INPUT: 120V or 277VAC 50/60 Hz
SWITCH RATING:
1000W Tungsten, 800W Ballast Switch Rating @ 120VAC
1500W Tungsten, 1200W Ballast Switch Rating @ 277VAC
8.3A Resistive @120VAC
5.4A Resistive @277VAC
OPERATING TEMPERATURE: 0° to 100°F (–18° to 38°C)
OPERATING HUMIDITY: 0-95% RH Non-Condensing
FACEPLATE COLOR: White
TIMING ACCURACY: Less Than 1% Deviation
WIRING CONNECTIONS: 6” Leadwires
120V Ground
Load
Neutral
ET616 Wiring Diagram
120V Hot
Green
Typical Wiring
(120VAC):
Black
Furnish and install a Grasslin Model ET616 Electronic Interval Timer. The timer shall fit a standard 2-1/2”
deep single or multigang wall box and decorator style wall plate. It shall be capable of being powered by
120 or 277 volts without a neutral connection. The unit shall offer preset time intervals of 5, 15, 30 or 60minutes and 3, 6, 9 or 12- hours set with “DIP” switches. Operation shall be via a single push button located on the front of the time switch. The push button shall operate as a standard on/off switch as well as to
initiate the selected countdown interval. The time switch shall incorporate a “scroll-up” or “scroll-down”
feature that allows the preset time to be adjusted up or down. The timer shall provide a “beep” and “flash”
mode to indicate the last minute of operation. If activated, the unit shall flash once at the one-minute mark
or beep once every 5 seconds from the one-minute mark to the shutdown point. The unit shall provide a
reset feature, activated by pressing the push button once during the last minute of operation, to reinitiate
the selected countdown interval. The time switch shall incorporate a backlighted LCD to display the countdown time. The unit shall contain a capacitor to retain the switch position during a power failure for up to
10 hours.
Green/Yellow
SPECIFIERS GUIDE
Red
Load
Neutral
ET616 Ordering Data
Model
ET616
www.grasslin.com
Voltage
Timing Interval
120 or 277 VAC
5, 15, 30, 60 Min.
50/60 Hz
3, 6, 9, 12 Hr.
201-825-9696
Switch Rating
1000 W (Tungsten) @ 120V
800W (Ballast) @ 120V
1500W (Tungsten) @ 277V
1200W(Ballast) @ 277V
19
In-Wall Electromechanical Timer
KM2 In-Wall Timer
24 Hour, 7 Day
Replaces standard wall switch (toggle) to provide automatic control of outdoor or
indoor lighting, fans, pumps, office machines, and other types of circuits. Captive trippers are easy to set, can’t be lost. 72 trippers provide up to 36 ON/OFF events in 24
hour period. Three way, OFF/AUTO/ON override switch provides continuous ON or OFF
positions. UL Listed. Easy wiring and installation.
SPECIFICATIONS
SWITCH RATING:
20A @ 120VAC, 60Hz
2400W Resistive
8A Inductive
1HP @ 120VAC
1350W Tungsten
ENVIRONMENTAL RATINGS:
Operating Temperature Range: –40°F to 180°F (–40°C to 85°C)
Operating Humidity: 0 to 95% non-condensing
WIRING CONNECTIONS:
(3) #14AWG color coded lead wires
Hot – Black
Switched – Red
Neutral – White
File #E83486
KIM2 Wiring Diagrams
Standard Installation
HOT (BLACK)
LOAD (RED)
LOAD
Dual Timer
(2-gang with 2 KM2’s)
• Captive trippers with 20 minute switching interval (2-1/3 hr. for 7 day)
• SPST 20A, 1HP @ 120V switch
• Replaces standard wall switches
• Multiple plates available
• Reliable synchronous timer motor
• Easy wiring and installation
3-Way Switch
HOT (BLACK)
NEUTRAL (WHITE)
NEUTRAL (WHITE)
FEATURES
3-Way Installation
(RED)
(BLUE)
2-gang/decorator
LOAD
4-gang/toggle
KM2 Ordering Data
20
2-gang/toggle
SPECIFIERS GUIDE
24 Hour
7 Day
Wallplate Configuration
Switch
KM2 ST-1G
KM2 STu-1G
KM2 ST-2G
KM2 STu-2G
KM2 ST-3G
KM2 ST-4G
KM2 ST-2D
KM2 ST-3D
KM2 ST-2R
KM2 STST-2G
KM2 SW-1G
KM2 SWu-1G
KM2 SW-2G
—
KM2 SW-3G
KM2 SW-4G
KM2 SW-2D
KM2 SW-3D
KM2 SW-2R
KM2 SWSW-2G
1 Gang
1 Gang, 3 Way
2 Gang, Toggle
2 Gang Toggle, 3 Way
3 Gang, Toggle
4 Gang, Toggle
2 Gang, Decorator
3 Gang, Decorator
2 Gang, Receptacle
2 Gang, Dual Timers
SPST
SPDT
SPST
SPDT
SPST
SPST
SPST
SPST
SPST
(2) SPST
Furnish and install a Grasslin KM2 ST
24 hour (SW, 7 day) “In-Wall” time
switch with 20 minute (2-1/3 hr.) interval captive trippers. Input voltage shall
be 120V and SPST (SPDT) contacts shall
be rated at 20A, 1HP @ 120VAC. Time
switch shall contain an OFF/AUTO/ON
manual switch.
www.grasslin.com
201-825-9696
In-Wall Electronic Timer
ET724 Electronic
In-Wall Timer
24 Hour and/or 7 Day
Replaces standard wall switch (toggle) to provide automatic control of
outdoor or indoor lighting, fans, pumps, office machines, and other
types of circuits. The unit can be programmed for 7-ON and 7-OFF
events daily or weekly. Large clear LCD display indicates the time of
day and ON/OFF status. The ET724 is designed to be mounted in a
standard decorator plate for a sleek modern look.
SPECIFICATIONS
INPUT: 120VAC, 60 Hz
SWITCH RATING:
15A Ballast @ 120VAC
15A Tungsten @ 120VAC
1800W Resistive
1HP Motor
OPERATING TEMPERATURE: 32° to 122°F (0° to 50°C)
FACEPLATE COLOR: White or Light Almond
TIMING ACCURACY: Less Than 1% Deviation
WIRING CONNECTIONS: 6” Leadwires
Profile
FEATURES
ET724 Wiring Diagram
Typical Wiring
(120VAC):
RED
BLACK
120VAC HOT
LIGHTS/
FAN/ETC.
WHITE
NEUTRAL
• Sleek profile
File #E149422
• Easy to program
• Single push-button control
• Mounts in standard wallbox
• Built-in rechargeable battery never needs replacement
• LCD display
• Flush mounted design
• Non-volatile memory
• Captive cover plate
• UL Listed and CSA Approved
• Wall plate included
SPECIFIERS GUIDE
Ground
(GRN/YEL)
Furnish and install a Grasslin model ET724 electronic in-wall 7 day time control. The timer shall fit into a standard 2-1/2” deep single or multigang wall
box and decorator style wallplate. It shall not protrude from the wall more
than 1/8” and have a captive cover plate over the programming keys. The
unit shall be capable of switching a 15 amp ballast or general purpose load
or 1 HP motor and have seven independently programmable events. The
battery backup will be a rechargeable NiMh type that does not require
replacement.
ET724 Ordering Data
Color
Voltage
Programs
Blocks
Battery Backup
White
Light Almond
120VAC, 60Hz
120VAC, 60Hz
7-ON and 7-OFF
7-ON and 7-OFF
MON~SUN, MON~FRI, SAT~SUN
MON~SUN, MON~FRI, SAT~SUN
30 Days
30 Days
Model Code
ET724
ET724-A
www.grasslin.com
201-825-9696
21
Lighting Controller 1 and 2 Channels
LightMaster
3”
PC Series
Light Sensor Controller
3/4 inch
conduit
fitting
The PC and LM series are one or two channel electronic lighting controls.They are provided with a waterproof light level sensor that can
be remotely mounted up to 330 feet away. For large installations, up
to 10 units (20 channels) can be connected to a single sensor. The
integral light sensitivity adjustment provides a wide range of settings,
making these units applicable for control of indoor and outdoor lighting as well as automatic awnings or shades. The PC1 and PC2 operate strictly via a light level adjustment. The PC2 unit has an independent light level setting for each channel. Either unit can be connected
in series with any Grasslin Time Switch to provide time-of-day control.
LS1 Transparent Sensor
Sensitivity: 0.2 to 50 Foot-Candles
Case: Transparent (IP65)
Application: Dusk to Dawn
APPLICATIONS:
• Parking Lights
• Warehouses
• Perimeter Lighting
• Schools
• Retail Stores
• 24-Hour Convenience Stores
SPECIFICATIONS
INPUT VOLTAGE: Separate models available for 120V or 277VAC;
50/60 Hz
RESISTIVE RATING: 10A @ 277VAC per Channel
BALLAST RATING: 8A @ 277VAC per Channel
OUTPUT RELAY: SPDT “dry” contacts for each channel
POWER CONSUMPTION: 2.5VA
TEMPERATURE RANGE:
Control Unit –4°F to 131°F (–20°C to 55°C)
Sensor –22°F to 158°F (–30°C to 70°C)
HUMIDITY RANGE:
Control Unit 0 to 95% RH non-condensing
Sensor 0 to 100% RH
WEIGHT: 8.5 oz.
MOUNTING: Surface & DIN rail
(NEMA 1 & 3R enclosures available)
LIGHT SENSITIVITY ADJ.: .2 to 50 Foot Candles
(10 to 1000 F.C. w/ optional sensor)
Time Delay Before
Switching Adjustable, 0 to 100 sec.
TIME SWITCH ACCURACY: ± 2.5 seconds per day @ 68°F (20°C)
LS2 Dark Sensor
Sensitivity: 10 to 1,000 Foot-Candles
Case: Dark UV Filter (IP65)
Application: Cloudy Environment
C.E.C Certified Title 24, Part 6 on all Models
File #E83486
FEATURES
•
•
•
•
•
•
Single channel (PC1) or Dual channel (PC2) models available
Single channel unit for 1 light level set point
Dual channel for 2 separate light level set points
Adjustable dial for foot-candle settings
Includes remote light sensor with lifetime warranty
DIN Rail/Surface mount or in our NEMA 3R Outdoor Enclosure
PC Series Wiring Diagram
3-4 and 6-7 closes on light level decreasing below setpoint
CH 1
CH 2
M
~
SENSOR
{
1
Dusk to Dawn Control
Interior Lighting Control
(Daylight Harvesting)
Wall
Wall
2
3
INPUT NO
4
5
6
7
NC NO
8
9
10
11
NC
Jumper required
between 9 and 10
PC Series Ordering Data
Model Code
Position sensor
w/arrow facing
wall
Position sensor
w/arrow facing
sunlight
SPECIFIERS GUIDE
Furnish and install a Grasslin, Model PC1, single (PC2, two) channel photo-electric
switch. The controller shall provide an integral light sensitivity adjustment, selectable from 0.2 to 1000 footcandles for low or high light level control (two channel
units shall have independent adjustments for each channel). A LED indication of
relay status shall be provided. The unit shall be provided with a remotely mounted
light level sensor, in weather proof housing, capable of being located up to 300 feet
from the control. The SPDT switch contact( s) shall be rated 10A @ 277VAC. The controller shall be surface, DIN rail or enclosure mounted.
22
Voltage
Channels
Mounting
PC1-120
PC1-240
PC1-277
120V
240V
277V
1
1
1
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
PC2-120
PC2-240
PC2-277
120V
240V
277V
2
2
2
Surface or DIN Rail
Surface or DIN Rail
Surface or DIN Rail
LM1-”X”-120
LM1-”X”-277
120V
277V
1
1
Substitute the Following for “X”:
LM2-”X”-120
LM2-”X”-277
120V
277V
2
2
Enclosure Options
“I” = NEMA 1 Indoor Enclosure
“IC” = NEMA 1 Indoor Enclosure
with Clear Cover
“O” = NEMA 3R Outdoor
Enclosure
“OC” = NEMA 3R Outdoor Enclosure
with Clear Cover
www.grasslin.com
201-825-9696
LightMaster Lighting Controller w/Electronic Time Switch 1 and 2 Channels
PC Digi Series
24 Hour and 7 Day Combination
Light Sensor Controller &
Time Switch
3”
3/4 inch
conduit
fitting
The PC Digi and LM Digi series are one or two channel electronic
lighting controls and time switch combination.They are provided
with a waterproof light level sensor that can be remotely mounted up to 330 feet away. For large installations, up to 10 units (20
channels) can be connected to a single sensor. The integral light
sensitivity adjustment provides a wide range of settings, making
these units applicable for control of indoor and outdoor lighting
as well as automatic awnings or shades. The PC “Digi” models
incorporate an integral one or two channel electronic timer with
automatic “Day Light Savings Time” changeover.
SPECIFICATIONS
INPUT VOLTAGE: Separate models available for 120V or 277VAC; 50/60 Hz
RESISTIVE RATING: 10A @ 277VAC per Channel
BALLAST RATING: 8A @ 277VAC per Channel
OUTPUT RELAY: SPDT “dry” contacts for each channel
POWER CONSUMPTION: 2.5VA
TEMPERATURE RANGE:
Control Unit –4°F to 131°F (–20°C to 55°C)
Sensor –22°F to 158°F (–30°C to 70°C)
HUMIDITY RANGE:
Control Unit 0 to 95% RH non-condensing
Sensor 0 to 100% RH
WEIGHT: 8.5 oz.
MOUNTING: Surface & DIN rail
(NEMA 1 & 3R enclosures available)
LIGHT SENSITIVITY ADJ.: .2 to 50 Foot Candles
(10 to 1000 F.C. w/ optional sensor)
Time Delay Before
Switching Adjustable, 0 to 100 sec.
TIME SWITCH ACCURACY: ± 2.5 seconds per day @ 68°F (20°C)
LS1 Transparent Sensor
Sensitivity: 0.2 to 50 Foot-Candles
Case: Transparent (IP65)
Application: Dusk to Dawn
LS2 Dark Sensor
Sensitivity: 10 to 1,000 Foot-Candles
Case: Dark UV Filter (IP65)
Application: Cloudy Environment
C.E.C Certified Title 24, Part 6 on all Models
File #E83486
FEATURES
• Single or two channel
• 10A switch rating
• Battery backup
• Delay Adjustment Potentiometer prevent nuisance activation
• Remote sensor
• Automatic Daylight Saving time changeover
PC Digi Series Ordering Data
Dusk to Dawn Control
Interior Lighting Control
(Daylight Harvesting)
Wall
Wall
Position sensor
w/arrow facing
wall
Position sensor
w/arrow facing
sunlight
Voltage
Channels
PC1-digi 20-120
PC1-digi 20-277
120V
277V
1
1
Surface or DIN Rail
Surface or DIN Rail
PC2-digi 30-120
PC2-digi 30-277
120V
277V
2
2
Surface or DIN Rail
Surface or DIN Rail
LM1-digi 20-”X”-120
LM1-digi 20-”X”-277
120V
277V
1
1
Substitute the Following for “X”:
LM2-digi 30-”X”-120
LM2-digi 30-”X”-277
120V
277V
2
2
Model Code
Mounting
Enclosure Options
“I” = NEMA 1 Indoor Enclosure
“IC” = NEMA 1 Indoor Enclosure
with Clear Cover
“O” = NEMA 3R Outdoor
Enclosure
“OC” = NEMA 3R Outdoor Enclosure
with Clear Cover
SPECIFIERS GUIDE
Furnish and install a Grasslin, Model PC1-digi 20, single (PC2-digi 30, two) channel combination photo-electric/time switch. The time/day will be stored in the event of a
power failure by a Lithium battery. The program schedule shall be stored in EEPROM. The controller shall provide an integral light sensitivity adjustment, selectable from
0.2 to 1000 foot-candles for low or high light level control. A LCD display shall provide indication of the time, day and status of each channel. A LED shall be provided to
indicate photoelectric output. The unit shall be provided with a remotely mounted light level sensor, in weather proof housing, capable of being located up to 300 feet
from the control. The SPDT switch contact(s) shall be rated 10A @ 277VAC. The controller shall be surface, DIN rail or enclosure mounted.
www.grasslin.com
201-825-9696
23
Photoelectric Controls
Conduit Mounting Series
These units are designed to provide “dusk-to-dawn” lighting control.
The dome and base are ultrasonically welded for added strength and
weather resistance (CM, CMS, CMP). The CMM Series features a gasketed heavy duty die-cast zinc housing. The units are easy to adjust
via a “slide” selector. They are available in non-swivel, swivel, “pencil”
swivel, and metallic versions. All units incorporate a built-in time
delay function designed to eliminate nuisance switching.
CMS Series
CM Series
SPECIFICATIONS
CELL: Cadmium Sulphide
CELL SIZE: 1/2” – CM, CMS, CMP
1” – CMM
TEMPERATURE RANGE: –40°F to 140°F
ACTIVATION:
Turn-on: .75 to 2.5FC – CM, CMS, CMP
1.5 to 5.5FC – CMM
Turn-off: Approximately 3 times turn-on
CM, CMS, CMP, CMM
For voltages and switch ratings, see chart below.
FEATURES
• 1/2” conduit mounting
• SPST, normally closed switch
• Built-in time delay
®
LISTED
®
C
LISTED
CMP Series
Conduit Mounting Series Wiring Diagrams
120/277V Models
Photoelectric
Switch
120V Models
Photoelectric
Switch
Spec Grade
5 year warranty
CMM Series
Line (Black)
(Red)
Neutral (White)
Load
(Black)
Line
120
VAC
(Red)
(Blue)
(White)
Neutral
208-277V Models
SPECIFIERS GUIDE
Furnish and install a Grasslin CM__ Series photo control.
Switch rating shall be 2000W Tungsten, 1800VA Ballast at
____ volts (50/60Hz). The unit shall be suitable for outdoor
installation via 1/2” conduit mounting. Temperature range
shall be –40°F to 140°F. A built-in time delay shall be incorporated to prevent nuisance switching. The SPST normally
closed switch shall provide fail “on” operation. Turn-on
shall be at .75 to 2.5FC (1.5 to 5.5FC for CMM Series) and
turn-off shall be at approximately 3 times turn-on.
For 277VAC:
L1 - Line
L2 - Neutral
L1
L2
Photoelectric
Switch
Photoelectric
Switch
(Black)
Line
(Red)
240V
(White)
Load
(Red)
277
VAC (White)
(Blue)
Neutral
Conduit Mounting Series Ordering Data
Models
Standard
24
Tungsten
Ballast
CMP-120
120
2000W
1800VA
CMP-287
208-277
2000W
1800VA
120/277
2000W
1800VA
“Pencil”
CM-120
CMS-120
CM-287
CMS-287
CMM-1127
Rating
Voltage
50/60 Hz
Swivel
CM-127
Metallic
www.grasslin.com
201-825-9696
Photoelectric Controls
Button Type Series
These units are designed to provide “dusk-to-dawn” lighting control.
The seems (BT Series) are ultrasonically welded for added strength
and weather resistance. The BT-120 and 287 mount through
11/16~13/16” hole with 3/4” threaded stem. The BTW-120 mounts
into standard outdoor junction box with stainless steel plate and gasket (included). The TL Series features locking type prongs that meet
ANSI C136.10-1988 and uses standard gap type or MOV surge
arrestor..
BT Series
FEATURES
• Flush mounting
• SPST, normally closed switch
• Built-in time delay
BTW
®
LISTED
®
C
LISTED
Turn-Lock Mounting Series
FEATURES
• Low profile design with locking-type prongs
• SPST, normally closed switch
• Built-in time delay
TL Series
SPECIFIERS GUIDE
SPECIFICATIONS
“BT” Series
CELL:
Cadmium Sulphide
CELL SIZE:
1/2”
TEMPERATURE RANGE:
–40°F to 140°F
ACTIVATION:
Turn-on:
3 to 5FC
Turn-off:
Approx. 3x turn-on
For voltages and switch ratings, see charts below.
“TL” Series
Cadmium Sulphide
1/2” or 1”
–40°F to 140°F
1FC, Avg.
3x turn-on, avg.
Furnish and install a Grasslin ____ Series photo control. Switch rating shall be ____
Tungsten, ____ Ballast at ____ volts. The unit shall be suitable for outdoor installation and temperature ranges of –40°F to 140°F. Mounting shall be via locking type
prongs (through 11/16” - 13/16” hole or flush in outdoor junction box). A built-in
time delay shall be incorporated to prevent nuisance switching (response time
shall be instant). The SPST normally closed switch shall provide fail “on” operation.
Turn-on shall be at ____ FC. Turn-off shall be approximately 3 times turn-on.
Button Type and Turn-Lock Ordering Data
Standard
Model
BT-120
BT-287
BTW-120
TLD-1185
TLD-1480*
TLD-120
TLD-287
RCB
SC
Rating
Voltage 50/60 Hz
Tungsten
Ballast
Cell Size
Response
Time
120
208-277
120
105-285
480
105-130
208-277
Receptacle w/Bracket
Shorting Cap
1500W
1500W
1500W
1200-2850W
1000W
1200W
2080-2770W
1200VA
1200VA
1200VA
1800-2800VA
1800VA
1800VA
2100-2800VA
1/2”
1/2”
1/2”
1”
1”
1/2”
1/2”
Delay
Delay
Delay
Delay
Delay
Delay
Delay
*Not UL/CSA
www.grasslin.com
201-825-9696
25
AC Hour Meter (Non-Reset Type)
FWZ Series
Dimensions in inches (mm)
File #E86119
C
FWZ 55
FWZ 53
• Weight: 1.2oz
• Flush panel retainer
mounted with wire
spring clip retainer
• Panel Opening: 1.36” x
0.90” rectangular (34.5
x 23mm)
Ordering Information
FWZ36 – voltage/freq.
*Rear access screw
terminals
File #LR44080
C
FWZ 36
• Bezel: 1.42” x 0.95”
(36 x 24mm)
• Capacity: 99.999.99 hours
• Digits: 7
• Voltage: 24, 120, 240, 50
or 60Hz models
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination: Combination
1/4” spade and screw
clamp. Rear access screw
terminals available
(model “K”)
FWZ 36, 53, and 55 Hour Meters are rectangular flush panel
mount designed to fit into tight locations. All can withstand
IP54 environmental rating (requires use of gasket).
• Bezel: 1.42” x 0.95”
(36 x 24mm)
• Capacity: 99.999.99
hours
• Digits: 7
• Voltage: 24, 120, 240, 50
or 60Hz models
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination:
Combination 1/4” spade
and screw clamp. Rear
• Bezel: 2.36” x 1.36”
(60 x 34.5mm)
• Capacity: 99.999.99
hours
• Digits: 7 – 0.16” high
numerals
• Voltage: 24, 120, 240, 50
or 60Hz models
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination:
Combination 1/4” spade
and screw clamp. Rear
access screw terminals
available (model “K”)
• Weight: 1.2oz
• Flush panel retainer
mounted with wire
spring clip retainer
• Panel Opening: 1.36” x
0.90” rectangular (34.5 x
23mm)
Ordering Information
FWZ36 – voltage/freq.
*Rear access screw
terminals
access screw terminals
available (model “K”)
• Weight: 1.8oz
• Flush panel retainer
mounted with slip-on
plastic retaining bracket
• Panel Opening: 2.06” x
1.08” rectangular (52 x
27.5mm)
Ordering Information
FWZ55 – voltage/freq.
FWZ55K* – voltage/freq.
*Rear access screw
terminals
Dimensions in inches (mm)
Dimensions in inches (mm)
All models also available with 1/4” spade terminals without screw clamp.
FWZ 72
Black Polycarbonate
• Bezel: 2.83” round (72mm)
3-hole
• Capacity: 99.999.99 hours
• Digits: 7 – 0.16” high
numerals
• Voltage: 24, 120, 240, 50 or
60Hz models
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination:
Combination 1/4” spade
and screw clamp. Rear
access screw terminals
available (model “K”)
• Weight: 1.8oz
• Flush panel mounted
with (3) 0.185” holes for
#8 screws
• Panel Opening: 1.75”
round (44.5mm) or 1.50” x
1.00” rectangular (38 x
25mm)
Ordering Information
FWZ72 – voltage/freq.
FWZ72B – voltage/freq.
FWZ72K* – voltage/freq.
*Rear access screw
terminals
FWZ 72B
Blue-Silver on Colorless
Frosted Polycarbonate
Dimensions in inches (mm)
26
www.grasslin.com
201-825-9696
AC Hour Meter (Non-Reset Type)
UWZ Series
UWZ 48A
UWZ 48
Enclosed Surface
Mount
Surface Mount
The UWZ 48 Series is designed to
meet IP20 environmental rating
for indoor applications. All models
are light grey color with white
numerals on black background.
Tenths and hundreths numerals
are yellow. An orange dial adjacent to the hundreths digit provides running indication.
• Bezel: 1.89” x 1.89” (48 x
48mm)
• Capacity: 99,999.99 hours
• Mounting: Surface
• Digits: 7 – 0.16” high
• Voltage: 24, 120, 240, 50
or 60Hz
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination: Screw Lugs
• Weight: 2.5oz.
Surface mounted type. The
UWZ 48 unit with plug-in
base where terminal
protection is not
necessary. The socket
base is easy to install and
connect. The meter is
simply plugged into the
base and secured by one
screw.
Ord. Info.: UWZ 48 –
voltage/freq.
• Bezel: 1.89” x 1.89”
(48 x 48mm)
• Capacity: 99,999.99 hours
• Mounting: Surface
• Digits: 7 – 0.16” high
• Voltage: 24, 120, 240, 50
or 60Hz
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination: Screw Lugs
• Weight: 2.5oz.
Dimensions in inches (mm)
File #LR44080
Wall mounted type. Used
in conjunction with a
terminal cover for added
safety, the UWZ 48A is
surface mounted.
Installation merely requires
fixing the base to wall or
panel with two screws,
wiring the base, and
plugging in the meter with
the terminal cover.
Ord. Info.: UWZ 48A –
voltage/freq.
Dimensions in inches (mm)
File #E86119
C
C
UWZ 48E
Flush Mount
• Bezel: 1.89” x 1.89”
(48 x 48mm)
• Capacity: 99,999.99 hours
• Mounting: Flush
• Digits: 7 – 0.16” high
numerals
• Voltage: 24, 120, 240, 50
or 60Hz
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination: Combination
1/4” spade and screw
clamp
• Weight: 2.1oz.
Flush mounted with
bracket. The UWZ 48E unit
fits into a 1.79 x 1.79in.
(45.5 x 45.5mm) cut-out.
The thickness of the panel
for flush mounting can be
up to 0.35in. (9mm). The
unit is secured in position
by a plastic slip-on
retaining bracket. Also fits
square or round openings
for 72mm meters with
optional 72mm bezel.
Ord. Info.: UWZ 48E –
voltage/freq.
Dimensions in inches (mm)
UWZ
48V
UWZ
52E
DIN Rail Mount
Flush Mount
• Bezel: 1.89” x 1.89”
(48 x 48mm)
• Capacity: 99,999.99 hours
• Mounting: DIN Rail
• Digits: 7 – 0.16” high
numerals
• Voltage: 24, 120, 240, 50
or 60Hz
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination:
Combination 1/4” spade
and screw clamp
• Weight: 2.5oz.
DIN rail mounting. A
special snap-on socket
base enables the unit to
be quickly and simply
fitted on DIN rail.
Ord. Info.: UWZ 48V –
voltage/freq.
Dimensions in inches (mm)
• Bezel: 2.28” round (58mm)
• Capacity: 99,999.99 hours
• Mounting: Flush
• Digits: 7 – 0.16” high
numerals
• Voltage: 24, 120, 240, 50
or 60Hz
• Power Consumption: 1VA
• Temperature: –40° to
160°F (–40° to 72°C)
• Termination: Combination
1/4” spade and screw
clamp
• Weight: 2.1oz.
Flush mounted with
bracket. The UWZ 52E
with round face is
fastened with a plastic
slip-on retaining bracket.
For larger cutouts up to a
60mm diameter, a slip-on
65mm ø bezel is available.
Ord. Info.: UWZ 52E –
voltage/freq.
Dimensions in inches (mm)
Panel
Cutout 2.0”
(50.5mm)
www.grasslin.com
201-825-9696
27
DC Hour Meter (Non-Reset Type)
GZ Series
GZ 40A
GZ 40B
GZ 41
• Bezel: 2.12” x 1.25” (54 x
32mm)
• Capacity: 99.999.9
hours
• Digits: 6 – 0.125 high
numerals
Hours: white on black
Tenths: red on white
• Voltage: 10-80VDC
• Power Consumption:
.03W @ 12VDC
.70W @ 48VDC
• Temperature: –22° to
150°F (–30° to 65°C)
Special Model Temp:
–40° to 185°F
(–40° to 85°C)
• Vibration Resistance: 10
to 75Hz @ 1-8g’s
• Termination: 1/4” spade
terminals
• Protected From: reverse
polarity, inductive
switch
• Weight: 2oz
• SAE Bezel: 2.31” dia.
(59mm)
• Capacity: 99.999.9
hours
• Digits: 6 – 0.125 high
numerals
Hours: white on black
Tenths: red on white
• Voltage: 4-40VDC and
10-80VDC
• Power Consumption:
.03W @ 12VDC
.70W @ 48VDC
• 3-Hole Bezel: 2.80” dia.
(72mm)
• Totally sealed case
• Capacity: 99.999.9
hours
• Digits: 6 – 0.125 high
numerals
Hours: white on black
Tenths: red on white
• Voltage: 4-40VDC and
10-80VDC
• Power Consumption:
.03W @ 12VDC
.70W @ 48VDC
• Temperature: –22° to
150°F (–30° to 65°C)
Special Model Temp:
–40° to 185°F
(–40° to 85°C)
• Vibration Resistance: 10
to 75Hz @ 1-8g’s
• Termination: 1/4” spade
terminals
• Protected From: reverse
polarity, inductive
switch
• Weight: 2oz
• Temperature: –22° to
150°F (–30° to 65°C)
Special Model Temp:
–40° to 185°F
(–40° to 85°C)
• Vibration Resistance: 10
to 75Hz @ 1-8g’s
• Termination: 1/4” spade
terminals
• Protected From: reverse
polarity, inductive
switch
• Weight: 2oz
Dimensions in inches (mm)
Dimensions in inches (mm)
GZ 40B
3-Hole Bezel
GZ 40A SAE Bezel
GZ 52A/B
The Hour Meter Without
Electrical Connection
RZ Series
The RZ hour meter records the
running time of machines,
vehicles, etc. which vibrate
during operation.
Operating Voltage
Current Consumption
Accuracy
Mechanical Movement
Display
Operation Indicator
Bezel
Electrical Connection
Polarity Protection
Mounting
Operating Temperature
Storage Temperature
Environmental Rating
Shock Resistance
Vibration Resistance
Approvals
28
GZ52A
8-30VDC
<3mA @12VDC
±0.5sec/day@20°C
2-Phase Step Motor
6 Digits (99999.9 Hours)
LED
Metal (Chrome) Circular
1/4” Quick Connectors
Diode
Flush (screw adj.)
–40°C - 85°C
–40°C - 90°C
IP 65
DIN EN60068-2-27
DIN EN60068-2-64
CE
GZ52B
8-30VDC
<3mA @12VDC
±0.5sec/day@20°C
2-Phase Step Motor
6 Digits (99999.9 Hours)
LED
Black (Plastic) Circular
1/4” Quick Connectors
Diode
Flush (screw adj.)
–40 C - 85°C
–40 C - 90°C
IP 65
DIN EN60068-2-27
DIN EN60068-2-64
CE
The automatic mechanism in
this meter converts vibrations
into energy which drives the
hour meter and minute sweep
hand. It is so sensitive, it is
capable of operating from the
slight vibration of a moving car.
LEGEND RZ52/RZ60
RZ52
D
h
v
RZ60
Bezel: 2.28”
= Model reference
= Rubber mounting assembly
= Horizontal installation
= Vertical installation
= With adapter ring for 60mm diameter cut-out
round (58mm)
ORDERING EXAMPLE:
RZ 52h
Vibratory hour meter for horizontal installation
www.grasslin.com
201-825-9696
Electromechanical Plug-In Timers
T25 Plug-in Timer
T35 Plug-in Timer
FEATURES
FEATURES
• 24 hour electromechanical plug-in timer
• Captive trippers
• Programming resolution
of 15 minutes
• Easy to program
• Manual override
• 24 hour electromechanical plug-in
timer
• Captive trippers
• Programming resolution of 15 minutes
• Easy to program
• Manual override
SPECIFICATIONS
INPUT VOLTAGE: 120VAC
SWITCH RATING: 15A @ 125VAC
Tungsten: 1250W, TV-4
1/3HP
Polarized 2-conductor plug and receptacle
SPECIFICATIONS
VOLTAGE: 110-120VAC
SWITCH RATING: 15A Resistive
AMBIENT TEMPERATURE RANGE: 14°F to 122°F
Grounded 3-conductor plug and receptacle
T240 Plug-in Timer
FEATURES
• 240VAC Plug
• 24 hour electromechanical plug-in timer
• Captive trippers
• Programming resolution of 15 minutes
• Heavy Duty 20A, 4800W
• Manual override
SPECIFICATIONS
VOLTAGE: 240VAC, 60Hz
SWITCH RATING: 20A Resistive
AMBIENT TEMPERATURE RANGE: 14°F to 122°F
Grounded 3-conductor plug and receptacle
Plug-in Timer Ordering Data
OPERATING FEATURES
Model
T25
T35
T240
www.grasslin.com
Switch Program
Reserve
Program On/Off Every
Shortest Switching Time
24 hour
24 hour
24 hour
No
No
No
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
201-825-9696
29
Electronic Plug-In Timers
CP924 Plug-in Timer
FEATURES
• 24 hour and 7 day electronic plug-in timer
• 12 programs
• Built-in battery for reserve carry-over
• Manual switch
• One minute interval
• Programming resolution of 1 minute
SPECIFICATIONS
INPUT VOLTAGE: 120VAC
SWITCH RATING: 15A Res. @ 120VAC
TIME BASE: Quartz Stabilized
AMBIENT TEMPERATURE RANGE: 14°F to 122°F
PROGRAMS: 12 (6 on; 6 off)
TD150 Plug-in Timer
FEATURES
• 24-Hour and 7-Day Electronic Plug-In timer
• Large LCD display and keys
• 16 programs (8 on, 8 off)
• One minute interval
• AA size battery (+100 hours carryover)
• Manual override button
• Countdown Timer Function (up to 10 hours)
• Convenient receptacle on side (maintains low profile)
• 24-Hour Military Time Format
SPECIFICATIONS
INPUT VOLTAGE: 120VAC 60Hz
SWITCH RATING: 15A Res.@ 120VAC, 1800W
2-prong polarized plug and receptacle
AMBIENT TEMPERATURE RANGE: 14°F to 122°F
PROGRAMS: 16 (8 on; 8 off)
Plug-in Timer Ordering Data
OPERATING FEATURES
Model
TD150
CP924
30
Switch Program
Reserve
Program On/Off Every
Shortest Switching Time
24 hour/7 day
24 hour/7 day
Yes
Yes
1 minute
1 minute
1 minute
1 minute
www.grasslin.com
201-825-9696
Accessories
E300 Compact
Plastic Outdoor
Enclosure
E200 Plastic
Outdoor
Enclosure
Plastic NEMA 3R raintight enclosure
with hinged door and latch.
Provisions for mounting Grasslin
timer modules. Five combination
1/2”-3/4” knockouts: In bottom, sides
and back. Exterior Size: 8.795” x
6.631” x 2.935” deep. Dark grey plastic finish.
E300
E150 Plastic
Indoor
Enclosure
E200
E110
Metal Indoor
Enclosure
Plastic NEMA 1 enclosure with hinged
door and latch. Provisions for mounting ANY Grasslin time control. Five
combination 1/2”-3/4” knockouts: In
bottom, sides and back. Exterior Size:
6.5” x 10” x 3.75” deep. Interior Size:
4.75” x 7.75” x 3” deep. Pale grey plastic finish.
E150C and E200C same as
E150/200 except with clear
see-thru cover
Plastic NEMA 3R raintight
enclosure with hinged door
and latch. Provisions for
mounting ANY Grasslin time
control. Five combination 1/2”3/4” knockouts: In bottom,
sides and back.Exterior Size:
6.5” x 10” x 3.75” deep. Interior
Size: 4.75” x 7.75” x 3” deep.
Dark grey plastic finish.
Steel NEMA 1 enclosure. Size:
5-1/8” x 7-7/8” x 3”; Grey
painted finish.
E110
E150
Miscellaneous Accessories
DIN-4
4” Metal Rail
DIN-12
12” Metal Rail
MB-DIN
DIN Rail Mounting Subbase for Digi 42/2
REPLACEMENT BATTERIES
Battery for Digi 42/2
BAT-42
BAT-Lithium Battery for Talento 800 Series
DC-FME
Clear Plastic Cover FM/1 Electronic
DC-FME-A Clear Plastic Cover FM/1 Electromechanical
HOUR METER ACCESSORIES
BEZ-55G
55mm Sq. Bezel Adapter, Grey, UWZ 48E
BEZ-55B
55mm Sq. Bezel Adapter, Black, UWZ 48E
BEZ-72
72mm Sq. Bezel Adapter, Grey, UWZ 48E
BEZ-72P
72mm Sq. Bezel Adapter w/pins for 3-Hole Pattern, Grey,
UWZ 48E
MB-48V
Mounting Base for UWZ 48V
MP-RZ60
60mm Steel Mounting Bracket, RZ Series
G55
Gasket for FWZ55 Models
G72
Gasket for FWZ72 Models
GRASSLIN 4 IN. SCREWDRIVER
55mm Bezel for UWZ 48E
Ord. Info.:
BEZ-55G
Grey
BEZ-55B
Black
www.grasslin.com
72mm Bezel for UWZ 48E
Ord. Info.:
BEZ-72
Grey
201-825-9696
72mm Bezel w/3 pins for round
3-bolt hole openings for UWZ 48E
Ord. Info.:
BEZ-72P
Grey
60mm steel mounting
bracket for RZ Series
Ord. Info.: MP-RZ60
31
REPLACEMENT CROSS REFERENCE
Discontinued Time Switches
The following time switches, which were discontinued, are shown below with their replacements. In all cases, the size and physical configuration of the replacement is identical, and in most cases the mounting holes are the same.
Discontinued Models
Discontinued
Models
Model -- Voltage
Voltage
Model
Recommended
Recommended
Replacement
Replacement
Electromechanical Single Pole
MIL 2008 SFTu-120
MIL 2008 SFTu-240
MIL 2008 SFTu-24
MIL 2008 SFWu-120
MIL 2008 SFWu-240
MIL 2008 SFWu-24
MIL 2008 QFRTu-120
MIL 2008 QFRTu-240
MIL 2008 QFRTu-24
MIL 2008 QFRWu-120
MIL 2008 QFRWu-240
MIL 2008 QFRWu-24
V86 S1hu
32
MIL 72A STuZH-120
MIL 72A STuZH-240
MIL 72A STuZH-24
MIL 72A SWuZH-120
MIL 72A SWuZH-240
MIL 72A SWuZH-24
MIL 72A QTuZH-120
MIL 72A QTuZH-240
MIL 72A QTuZH-24
MIL 72A QWuZH-120
MIL 72A QWuZH-240
MIL 72A QWuZH-24
talento 121
Electromechanical
Single or Double Pole
GM1ST
GMDST
GM1QT
GMDQT
GM1SW
GMDSW
GM1QW
GM1QW
Electromechanical
Double Pole
GM40
GM40
GM40Q
GM40Q
GM40W
GM40W
GM40QW
GM40QW
Defrost Timers
DTMV
DTQMV
DTMV-M
DTQMV-M
DTMV-IM
DTQMV-IM
DTMV40
DTQMV40
DTMV40-M
DTQMV40-M
DTMV40-IM
DTQMV40-IM
Electronic Two Channel
Digi 32-72/2-120
Digi 32-72/2-240
Digi 32-72/2-24
Digi 56-72/2-120
Digi 56-72/2-240
Digi 56-72/2-24
Digi 322-45/2Y-120V
Digi 322-45/2Y-24V
GMX2 digi 32-I-120
GMX2 digi 32-I-240
GMX2 digi 32-I-24
GMX2 digi 32-O-120
GMX2 digi 32-O-240
GMX2 digi 32-O-24
Digi 42/2-120
Digi 42/2-240
Digi 42/2-24
Digi 42/2-120
Digi 42/2-240
Digi 42/2-24
talento 892-120V
talento 892-24V
GMX2 digi 42-I-120
GMX2 digi 42-I-240
GMX2 digi 42-I-24
GMX2 digi 42-O-120
GMX2 digi 42-O-240
GMX2 digi 42-O-24
Discontinued Models
Model - Voltage
Recommended
Replacement
Electronic One Channel
Digi 322-45/1Y-120V
Digi 322-45/1Y-240V
Digi 322-45/1Y-24V
FM/1 digi 12-12
FM/1 digi 16-12DC
FM/1 digi 16-120
FM/1 digi 16-240
FM/1 digi 16-24
GM1 digi 20-I
GMD digi 20-I
GM1 digi 42
GMD digi 42
GMX digi 12-I-120
GMX digi 12-I-240
GMX digi 12-I-24
GMX digi 12-I-12DC
GMX digi 12-O-120
GMX digi 12-O-240
GMX digi 12-O-24
GMX digi 12-O-12DC
GMX digi 16-I-120
GMX digi 16-I-240
GMX digi 16-O-120
GMX digi 16-O-240
MIL 72A digi 16-120
MIL 72A digi 16-240
MIL 72A digi 16-24
MIL 72E digi 16-120
MIL 72E digi 16-240
MIL 72E digi 16-24
talento 891-120V
talento 891-240V
talento 891-24V
FM/1 digi 42-12
FM/1 digi 42-12DC
FM/1 digi 20-120
FM/1 digi 20-240
FM/1 digi 20-24
GM40E
GM40E
GM40E42
GM40E42
GMX digi 20-I-120
GMX digi 20-I-240
GMX digi 20-I-24
GMX digi 42-I-12DC
GMX digi 20-O-120
GMX digi 20-O-240
GMX digi 20-O-24
GMX digi 42-O-12DC
GMX digi 20-I-120
GMX digi 20-I-240
GMX digi 20-O-120
GMX digi 20-O-240
Digi 20A-120
Digi 20A-240
Digi 20A-24
Digi 20E-120
Digi 20E-240
Digi 20E-24
Electronic Multi-Channel
Digi 127 (4 channel)
Digi 127-9 (9 channel)
Digi 128 (4 channel)
Digi 322-45/4-120V
Digi 322-45/4Y-120V
Digi 322-45/4Y-240V
Digi 322-45/4Y-24V
talento 894-120V
SRS-3800 (8 Channel)
talento 894-120V
talento 894-120V
talento 894-120V
talento 894-240V
talento 894-24V
www.grasslin.com
201-825-9696
COMPETITIVE CROSS REFERENCE
Competitive model numbers are provided as a general reference and do not imply exact equals as some features may vary.
Electronic Time Switches
24 Hour Time Switches
Grasslin
Intermatic
T101
T101(B)
T1906
T101P
T101(B)
T1905-R
T104
T101
T101(B)
T102
T102(B)
T105
T185
T1905
T1906
T101P
T101R
T101(B)
T102P
T102R
T102(B)
T106R
T1905R
T1906R
T101
T102
T103
T104
T105
T103
T103P
T103R
T104
T104P
T104R
GM40
Tork
1101
8001
Paragon
P101
1015-00RS
1101-N
8001-N
P101P
42011-00
1104
4004-20
P104
P101
4001-00
4002-71
4005-00
1015-00RS
1101
1102
8001
8004
1101-N
1102-N
8001-N
8004-N
1101
1102
1103
1104
1101-N
1102-N
1103-N
1104-N
8002N
8042N
P101P
4011-00(P)
42011-00
24011-20
P103
P104
4003-00
4004-71
1015-00RS
P103P
P104P
4011-00(P)
4013-00
4014-71
42013-00
42013-20
Universal Replacement
Defrost Timers
Grasslin
DTMV40
www.grasslin.com
Paragon
Precision
8041-00
8141-00
8143-00
8145-00
8041-00
8043-00
8045-00
8046-00
8047-00
8141-20
8143-20
8145-20
8041-20
8043-20
8045-20
8046-20
8047-20
8245-20
8243-20
8247-20
6041-00
6141-00
6143-00
6145-00
6041-00
6043-00
6045-00
6047-00
6141-20
6143-20
6145-20
6041-20
6043-20
6045-20
6047-20
6245-20
6243-20
6247-20
201-825-9696
Grasslin
Single Channel 24 Hour
Paragon
Intermatic
Tork
GMX digi 20-I-120
GMX digi 20-OC-120
GMX digi 20-I-240
GM40E-120
GM40E-120
GM40E-240
GM40E-120
GM40E-240
EC4000/120V
EC4000PC/120V
EC4000/208-277V
EC4004/120V
EC4004PC/120V
EC4004/208-277V
EC4005PC/120, 208-240V
EC4005PC/120, 208-240V
ET100C
ET101C
ET103C
ET103C
E120
E120-2
E101
E101-2
E103
ET715C
ET715C
ET171C
ET171C
ET173C
ET173C
ET715C
-
EW120
EW120-2/-3
EW101
EW101-2
EW103
EW103-2/-3
DIN101A
DIN100
-
DIN200
1 and 2 Channel 24 Hour / 7 Day
GMX digi 20-I-24
GMX digi 20-I-120
GMX digi 20-I-240
GMX digi 20-OC-120
GM40E-120
GM40E-240
GM40E-120
GM40E-240
GMX digi 42-I-120
Digi 20A-120
Digi 42A-24
Digi 42A-120
Digi 42A-240
Digi 42/2-120
EC7000/24V
EC7000/120V
EC7000/208-277V
EC7000PC/120V
EC7004/120V
EC7004/208-277V
EC7005PC/120,208-240V
EC7005PC/120,208-240V
EC71/30S/120
EC71D/30S/24
EC71D/30S/120
EC71D/30S/240
-
One, Two, Four & Eight Channel Electronic
GMX 891-I-120
EC71/18S/120
ET70115C
talento 891-120
EC71D/18S/120
talento 891-24
EC71D/18S/24
GMX 892-I-24
EC72/24
ET70215CR24
GMX 892-I-120
EC72/120
ET70215C
talento 892-24
EC72D/24
talento 892-120
EC72D/120
GMX 894-I-24
EC74/50S/24V
ET70415CR24
GMX 894-I-120
EC74/50S/120V
ET70415CR
talento 894-24
EC74/120D/24V
EC74/120D/120V
talento 894-120
SRS 3800
EC77/120, 240
All talento 800 series units are available with or without an enclosure
DTS100A
DTS100A-24
DTS200A-24
DTS200A
DZS400A-24
DZS400A
-
7 Day Electromechanical Time Switches
Grasslin
GM40W
Intermatic
Tork
Paragon
T171
T172
T171B
T172B
T175
T176
T1975
T1976
T2005
T2006
7100
7102
7120
7122
W100
W120
8001
8004
8007
8008
P101-S
1015-00RS
1015-00RSB
42011-00
42011-20
4005-00S
4005-00SB
4006-71S
T173
T174
T1871BR
T1872BR
T7801B
T7802B
7200
7202
7220
7222
W200
W202
W220
W222
8042N
4003-00S
4003-00S
4004-71S
4013-SS0
4014-71S
P103-S
P103-PS
P104-S
P104-PS
42013-00
42013-20
7008-00
7008-71
33
COMPETITIVE CROSS REFERENCE
Spring Wound Interval Timers
MINUTE INTERVALS
Grasslin
KLT5M
KLT5M-W
KLT5MH
KLT5MH-W
KLT5M-A
KLT5MH-A
KLT15M
KLT15M-W
KLT15MH
KLT15MH-W
KLT15MC
KLT15MC-W
KLT15M-A
KLT15MH-A
KLT15MC-A
KLT30M
KLT30M-W
KLT30MH
KLT30MH-W
KLT30MC
KLT30MC-W
KLT30M-A
KLT30MH-A
KLT30MC-A
KLT60M
KLT60M-W
KLT60MH
Paragon
SWP5M
SWPD15M
SWPD15M-W
SWPD15MH
SWPD15MH-W
SWP15M
SWP15MH
SWPD30M
SWPD30M-W
SWPD30MH
SWPD30MH-W
SWP30M
SWP30MH
SWPD60M
SWPD60M-W
SWPD60MH
Intermatic
FD5M
FG5MH
FF5M
FF5MH
FD15M
FD15MH
FF15M
FF15MH
FD30M
FD30MH
FF30M
FF30MH
FD60M
FD60MH
HOUR INTERVALS
Tork
A505M
A505MW
A515M
A515MW
A515MH
A515MHW
A530M
A530MW
A530MH
A530MHW
A560M
A560MW
A560MH
Rhodes
9304M
9304MH
9315MI
9315MH
9315MHI
9315MHW
9315MH
9330MI
9330MW
9330MHI
9330M
9330MH
90011
9360MI
9360MW
9360MHI
Grasslin
KLT60MH-W
KLT60M-A
KLT60MH-A
KLT2H
KLT2H-W
KLT2HH
KLT2HH-W
KLT2H-A
KLT2HH-A
KLT4H
KLT4H-W
KLT4HH
KLT4HH-W
KLT4H-A
KLT4HH-A
KLT6H
KLT6H-W
KLT6HH
KLT6HH-W
KLT6H-A
KLT6HH-A
KLT12H
KLT12H-W
KLT12HH
KLT12HH-W
KLT12H-A
KLT12HH-A
Paragon
SWPD60MH-W
SWP60M
SWP60MH
SWP2H
SWP2HH
SWP4H
SWP4HH
SWPD6H
SWP6H
SWP6HH
SWPD12H
SWPD12H-W
SWPD12HH
SWPD12HH-W
SWP12H
SWP12HH
Intermatic
FF60M
FF60MH
FD6H
FD6HH
FF6H
FF5HH
FD12H
FD12HH
FF12H
FF12HH
Tork
A560MHW
A502H
A502HW
A502HH
A502HHW
A504H
A504HW
A504HH
A504HHW
A506H
A505HW
A506HH
A506HHW
A512H
A512HW
A512HH
A512HHW
-
Rhodes
9360M
9360MH
9302H
9302HH
9304H
9304HH
9306HI
9306H
9306HH
9312HI
9312HW
9312HHI
9312HHW
9312H
9312HH
Photo Controls
GRASSLIN
CM-120
CM-287
CM-127
CMS-120
CMS-287
CMP-120
CMP-287
CMM-1120
CMM-1287
CMM-1127
BT-120
BT-287
BTW-120
TLD-1120
TLDV-1120
TLD-1287
TLDV-1287
TLD-1185
TLDV-1185
TLD-1480
TLDV-1480
TLD-120
TLDV-120
TLD-287
TLDV-287
TLI-1120
TLI-1185
TLI-1480
RG
RB
RCB
SC
34
PARAGON
CW201-00
CW201-71
CW201-70
CW201S-00
PN201-00
CW201-00
CW201-71
CW201-70
LB201-00
LB201-71
LB201W-00
TL201-00
TL201-71
TL201-70
TL201-71
TB201-99
SC201-99
INTERMATIC
K4121
K4124
K4221
K4224
K4021
K4022, 4, 33
K4321
LC4521
K4524
K4535
K4535
LC4521
LC4523
K1221
K122
K4500
TORK
2000
2000-2
2000-7
2001
2002
2021
2022
2101
2104
2107
3000
3002
3010
5001S
5001M
5004S
5004M
5007S
5007M
5008S*
5008M*
5021S
5021M
5024S
5024M
2005
2007
2008*
2223
2224
2421
5500
ALR
PT-15
PT-168
PT-20
SPT-15
SPT-168
TL-115
TL-1168
AT-15
AT-168
AT-20
AA-105
AA-1068
AA-105W
M-120
BF-208
M-208-277
BF-PV
M-PV
M480
M-480
LC-120
BF-120
LC-208-277
BF-208-277
AM-1-A-NB
AM-1-A
AM-2-A
SC-10
FISHER PIERCE
FT-15
FT-168
SFT-15
SFT-168
FL-115
FA-105
FA-1068
FA-105W
NFP-120
NFP-120E
FP-208-277
NFP-277E
NFP-480
NFP-120
NFP-208-277
7760
7790
7794
S476-81
S476-81
S-476-71
NS1038-1
www.grasslin.com
PRECISION
T-15
T-168
ST-15
ST-168
ET-15
ET-168
A-105
A-1068
A-105W
LM-2275
LM-58275
P-26275
P7275
LM-7275MOV
P-2275
LM-2275MOV
P-68275
LM-68275MOV
8660
8690
8694
603
M-2A
JP-275
201-825-9696
GRASSLIN HVAC/R SALES REPRESENTATIVES
State
City
Agency Name
Phone
Fax
Alabama
Alabama - S
Alaska
Arizona
Arkansas
California - N
California - S
Colorado
Connecticut
Delaware-N
Delaware-S
Florida
Georgia
Hawaii
Idaho - N
Idaho - S
Illinois - N
Illinois - S
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississipi
Missouri
Montana
Nebraska
Nevada - N
Nevada - S
New Hampshire
New Jersey
New Mexico
New York - N
New York - S
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania - E
Pennsylvania - W
Rhode Island
South Carolina
South Dakota
Tennessee - E
Tennessee-W
Texas
Utah
Vermont
Virginia
Washington
Washington D.C.
West Virginia
Wisconsin
Wyoming
Puerto Rico
Conyers, GA
Seminole, FL
Redmond, WA
Laguna Beach, CA
Baton Rouge, LA
Sacramento, CA
Laguna Beach, CA
Lakewood, CO
Ballston Spa, NY
Ho-Ho-Kus, NJ
Millersville, MD
Seminole, FL
Conyers, GA
Laguna Beach, CA
Redmond, WA
Salt Lake City, UT
Fort Wayne, IN
Hazelwood, MO
Fort Wayne, IN
Omaha, NE
Olathe, KS
Chagrin Falls, OH
Baton Rouge, LA
Ballston Spa, NY
Millersville, MD
Ballston Spa, NY
Holland, MI
Wausau, WI
Laurel, MS
Hazelwood, MO
Lakewood, CO
Omaha, NE
Sacramento, CA
Laguna Beach, CA
Ballston Spa, NY
Ho-Ho-Kus, NJ
El Paso, TX
Ballston Spa, NY
Ho-Ho-Kus, NJ
Matthews, NC
Wausau, WI
Chagrin Falls, OH
Fort Worth, TX
Redmond, WA
Ho-Ho-Kus, NJ
Chagrin Falls, OH
Ballston Spa, NY
Matthews, NC
Wausau, WI
Conyers, GA
Laurel, MS
Fort Worth, TX
Salt Lake City, UT
Ballston Spa, NY
Millersville, MD
Redmond, WA
Millersville, MD
Chagrin Falls, OH
Wausau, WI
Lakewood, CO
Southland Marketing
Ron McLaughlin & Assoc
Pacific NW Reps
The John Albritton Co.
Lobell-McCarthy
D-Tech Sales
The John Albritton Co.
Vista Sales Associates
Gimper IV, LLC
United Components, Inc.
Preferred Sales
Ron McLaughlin & Assoc
Southland Marketing
The John Albritton Co.
Pacific NW Reps
GSC/Northwest & Co.
Refrigeration Solutions Inc
Meglio-ESI
Refrigeration Solutions Inc
Davidson Rep Co.
Meglio-ESI
TradRep
Lobell-McCarthy
Gimper IV, LLC
Preferred Sales
Gimper IV, LLC
Pro Sales Inc
BP Marketing
Lobell-McCarthy
Meglio-ESI
Vista Sales Associates
Davidson Rep Co.
D-Tech Sales
The John Albritton Co.
Gimper IV, LLC
United Components, Inc.
Danko Sales Co LLC
Gimper IV, LLC
United Components, Inc.
Midsouth Marketing
BP Marketing
TradRep
Hill & Associates
Pacific NW Reps
United Components, Inc.
TradRep
Gimper IV, LLC
Midsouth Marketing
BP Marketing
Southland Marketing
Lobell-McCarthy
Hill & Associates
GSC/Northwest & Co.
Gimper IV, LLC
Preferred Sales
Pacific NW Reps
Preferred Sales
TradRep
BP Marketing
Vista Sales Associates
Grasslin Controls Corp.
770-760-0627
727-320-0981
425-836-0907
949-494-7030
214-704-1119
888-999-8445
949-494-7030
303-989-7636
518-885-8901
201-612-9119
410-987-1425
727-320-0981
770-760-0627
949-494-7030
425-836-0907
801-288-1000
260-486-3076
314-524-4424
260-486-3076
402-738-8705
913-397-6000
440-247-3880
225-751-8760
518-885-8901
410-987-1425
518-885-8901
616-399-1816
414-469-7446
601-310-5134
314-524-4424
303-989-7636
402-738-8705
888-999-8445
949-494-7030
518-885-8901
201-612-9119
915-855-7545
518-885-8901
201-612-9119
704-814-9372
414-469-7446
440-247-3880
972-869-1200
425-836-0907
201-612-9119
440-247-3880
518-885-8901
704-814-9372
414-469-7446
770-760-0627
601-310-5134
972-869-1200
801-288-1000
518-885-8901
410-987-1425
425-836-0907
410-987-1425
440-247-3880
414-469-7446
303-989-7636
201-825-9696
770-760-0727
727-320-0973
425-868-0920
949-494-7602
972-530-7633
800-877-3001
949-494-7602
303-989-7912
518-885-8904
201-612-8736
410-987-1727
727-320-0973
770-760-0727
949-494-7602
425-868-0920
801-288-1085
260-486-3076
314-524-6447
260-486-3076
402-502-2342
913-397-7003
888-326-1828
225-751-8762
518-885-8904
410-987-1727
518-885-8904
616-399-5310
800-280-0977
225-751-8762
314-524-6447
303-989-7912
402-505-2342
800-877-3001
949-494-7602
518-885-8904
201-612-8736
602-298-9365
518-885-8904
201-612-8736
704-814-9403
800-280-0977
888-326-1828
972-869-0066
425-868-0920
201-612-8736
888-326-1828
518-885-8904
704-814-9403
800-280-0977
770-760-0727
225-751-8762
972-869-0066
801-288-1085
518-885-8904
410-987-1727
425-868-0920
410-987-1727
888-326-1828
800-280-0977
303-989-7912
201-825-8694
www.grasslin.com
201-825-9696
35
GRASSLIN ELECTRICAL SALES REPRESENTATIVES
36
State
City
Agency Name
Phone
Fax
Alabama
Alaska
Arizona
Arkansas
California - N
California - S
Colorado
Connecticut
Delaware
Florida
Florida Panhandle
Georgia
Idaho - N
Idaho - S
Illinois - N
Illinois - S
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi - N
Mississippi - S
Missouri
Montana
Nebraska
Nevada - N
Nevada - S
New Hampshire
New Jersey - N
New Jersey - S
New Mexico
New York - N
New York - S
North Carolina
North Dakota
Ohio - N
Ohio - S
Oklahoma
Oregon
Pennsylvania - E
Pennsylvania - W
Rhode Island
South Carolina
South Dakota
Tennessee - E
Tennessee - W
Texas - N
Texas - S
Utah
Vermont
Viginia
Washington
Washington D.C.
West Virginia - N
West Virginia - S
Wisconsin-E, U.P.
Wisconsin - W
Wyoming - E
Wyoming - W
Puerto Rico
Birmingham, AL
Glenn & Assoc.
Grasslin Controls Corp.
Grasslin Controls Corp.
Parr-Park & Associates, Inc.
Century Sales
E. R. I.
TKI (Tim Kaylor Inc.)
Electra Spec Inc.
Fitzgerald Spector Inc.
Dynamic Sales Assoc.
Glenn & Assoc.
Glenn & Assoc.
Grasslin Controls Corp.
Wilson Sales
M & M Electrical Sales
Meglio-ESI
GES/Goldschmidt
Current Solutions Inc
Meglio-ESI
GES/Goldschmidt
Grasslin Controls Corp.
Electra Spec Inc.
One Source
Electra Spec Inc.
Day Sales
Fruen’s Sales Company
Parr-Park & Assoc.
Grasslin Controls Corp.
Meglio-ESI
Grasslin Controls Corp.
Current Solutions Inc
Century Sales
E. R. I.
Electra Spec Inc.
SDM Metro
Fitzgerald Spector Inc.
Grasslin Controls Corp.
RD Wright Inc
SDM Metro
McNeill & Co.
Fruen’s Sales Company
Westwood Electrical Sales Corp.
GES/Goldschmidt
Geo. E. Anderson Co-No.
Grasslin Controls Corp.
Fitzgerald Spector Inc.
Five Star Sales
Electra Spec Inc.
McNeill & Co.
Fruen’s Sales Company
Electrical Sales Assoc.
Parr-Park & Associates, Inc.
Geo. E. Anderson Co-No.
Geo. E. Anderson Co-So.
Wilson Sales
Electra Spec Inc.
One Source
Grasslin Controls Corp.
One Source
Five Star Sales
GES/Goldschmidt
M & M Electrical Sales
Fruen’s Sales Company
TKI (Tim Kaylor Inc.)
Wilson Sales
Glenn International
205-322-8501
201-825-9696
201-825-9696
901-454-0115
925-609-9488
714-434-9008
303-451-9200
508-946-4070
215-887-9744
813-242-8222
205-322-8501
205-322-8501
201-825-9696
801-292-4867
920-766-7703
314-524-4424
513-641-1708
402-333-6535
913-397-6000
513-641-1708
201-825-9696
508-946-4070
410-309-4900
508-946-4070
616-794-1481
763-546-7173
901-454-0115
201-825-9696
314-524-4424
201-825-9696
402-333-6535
925-609-9488
714-434-9008
508-946-4070
516-536-2600
215-887-9744
201-825-9696
518-966-5980
516-536-2600
704-375-7900
763-546-7173
440-835-9960
513-641-1708
214-428-3731
201-825-9696
215-887-9744
866-885-0648
508-946-4070
704-375-7900
763-546-7173
615-242-2774
901-454-0115
214-428-3731
713-461-6400
801-292-4867
508-946-4070
410-309-4900
201-825-9696
410-309-4900
866-885-0648
513-641-1708
920-766-7703
763-546-7173
303-451-9200
801-292-4867
787-757-6000
205-322-6115
201-825-8694
201-825-8694
901-454-9703
925-609-9661
714-434-9260
303-451-9300
866-946-4070
215-887-6724
813-242-8224
205-322-6115
205-322-6115
201-825-8694
801-292-4636
920-766-0524
314-524-6447
513-641-2144
402-334-6863
913-397-7003
513-641-2144
201-825-8694
866-946-4070
410-309-4910
866-946-4070
616-794-1499
763-546-7024
901-454-9703
201-825-8694
314-524-6447
201-825-8694
402-334-6863
925-609-9661
714-434-9260
866-946-4070
516-764-0755
215-887-6724
201-825-8694
518-966-5985
516-764-0755
704-375-6447
763-546-7024
440-835-3588
513-641-2144
214-428-6111
201-825-8694
215-887-6724
866-885-5770
866-946-4070
704-375-6447
763-546-7024
615-242-2791
901-454-9703
214-428-6111
713-461-8155
801-292-4636
866-946-4070
410-309-4910
201-825-8694
410-309-4910
866-885-5770
513-641-2144
920-766-0524
763-546-7024
303-451-9300
801-292-4636
787-769-1851
Memphis, TN
Concord, CA
Santa Ana, CA
Castle Rock, CO
Middleboro, MA
Jenkintown, PA
Tampa, FL
Birmingham, AL
Birmingham, AL
Bountiful, UT
Kaukauna,WI
Hazelwood, MO
Cincinnati, OH
Marion, IA
Olathe, KS
Cincinnati, OH
Middleboro, MA
Columbia, MD
Middleboro, MA
Belding, MI
Plymouth, MN
Memphis, TN
Hazelwood, MO
Omaha, NE
Concord, CA
Santa Ana, CA
Middleboro, MA
Rockville Center, NY
Jenkintown, PA
Greenville, NY
Rockville Center, NY
Charlotte, NC
Plymouth, MN
Westlake, OH
Cincinnati, OH
Dallas, TX
Jenkintown, PA
Pittsburgh, PA
Middleboro, MA
Charlotte, NC
Plymouth, MN
Nashville, TN
Memphis, TN
Dallas, TX
Houston, TX
Bountiful, UT
Middleboro, MA
Columbia, MD
Columbia, MD
Pittsburgh, PA
Cincinnati, OH
Kaukauna, WI
Plymouth, MN
Castle Rock, CO
Bountiful, UT
Carolina, PR
www.grasslin.com
201-825-9696
Application Hint
KLT Twist Timers Technical Information Bulletin
(Switch Configuration)
The KLT Series spring wound timers incorporate a normally open and normally
closed switch contact. Both can be used independently or simultaneously as
illustrated below.
www.grasslin.com
201-825-9696
37
Application Hint
Grasslin PC Series Wiring
38
www.grasslin.com
201-825-9696
Application Hint
DTMV40 Installation into
Existing Enclosure
SETUP PROCEDURE
1. Disconnect power.
2. Disconnect wiring from existing defrost timer.
3. Remove Paragon mechanism from enclosure.
4. Remove Grasslin DTMV40 printed circuit board from it’s enclosure (gray plastic).
5. If necessary, adjust DIP switches and apply terminal identification label as indicated in the
DTMV40 operating instructions.
6. Engage tabs on left side of printed circuit board into enclosure, and swing PCB into place.
7. Apply extra DTMV40 label to existing enclosure door.
8. Reconnect wires to DTMV40.
9. Attach gray faceplate over PCB and secure using existing enclosure locking latch as illustrated.
10. Reapply power.
www.grasslin.com
201-825-9696
39
Application Hint
RZ Vibratory Hour Meter
Response Plot
Orientation
40
www.grasslin.com
201-825-9696
Grasslin... the Global Leader in Time and Energy Controls for OEMs,
Distributors, Contractors and Users of Time Controls.
Today, Grasslin is one of the world's leading time control producers with
a product range of approximately 2,000 timing devices. Grasslin's products have set the standards for quality and innovation in technology
and design. Our three modern manufacturing locations are ISO 9001
registered. Grasslin products are sold in over 50 countries throughout
the world. They carry the UL and CE mark as well as numerous other
approbations. We look forward to serving your time control requirements with quality products and service second to none.
Warranty
Grasslin Controls’ products are warranted to be free from defects in workmanship or material under normal use and service for a period of
one year from date of purchase by the user.
Grasslin’s obligation under this Warranty is limited to replacing, without charge, any part or parts of a defective unit which shall, within the
time limit set forth above, be received at Grasslin Controls Corporation, Mahwah, New Jersey provided that transportation charges are prepaid. Grasslin will pay return charges.
This Warranty will not apply if, in the judgment of Grasslin Controls, damage or failure has resulted from accident, alteration, misuse, abuse
or operation in an incorrect power supply.
Any adjustment or replacement of defective parts made under this Warranty does not void the Warranty, nor does it extend the original
Warranty period.
Under no circumstances shall Grasslin Controls be liable to purchaser or any third party for any loss of profits or other direct or indirect
costs, expenses, losses or consequential damages arising out of or as a result of any defects in or failure of Grasslin Products or any part
or parts thereof.
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EITHER EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY,
MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR ANY OTHER MATTER.
Grasslin Controls reserves the right under its product improvement policy to change construction or design details, and specifications without notification or obligation. Photographs and product descriptions in this catalog are not binding in detail.
www.grasslin.com
201-825-9696
41
Grasslin Controls Corporation
31 Industrial Avenue
Mahwah, New Jersey 07430 USA
Tel: 201-825-9696
www.grasslin.com
Fax: 201-825-8694
©2006 Grasslin Controls Corporation All Rights Reserved
Specifications and other information in this catalog are subject to change without notice.
Download