Grounding & Bare Copper Proof Positive® Copper-Clad Steel CONSTRUCTION AT A GLANCE CONDUCTOR TYPE 1 Copper-clad steel Applications SPECIFICATIONS • Used as uninsulated hook ups, jumpers, and grounds in electrical and substation construction Southwire’s Proof Positive® Copper-Clad Steel Conductor meets or exceeds the following applicable ASTM specifications: • Suitable for direct burial •B 910: Annealed Copper-Clad Steel Wire • Unique serial number provides proof of ownership for traceability OPTIONS • Solid (1 strand) CONSTRUCTION DETAILS • Stranded (7 and 19 strands) •Bare copper-clad steel stranded conductor • 30% or 40% conductivity, DSA (dead soft annealed) • Low carbon (LC) steel •Center strand is tinned and has a laseretched, unique set of codes that will be visible for the life of the conductor •Code is comprised of: • A license code • A serial number unique to every foot of cable • The website URL which stores the ownership information •One strand in the outermost layer of the construction is also tinned 1 41 Section C Solid Constructions Size (AWG) 0.1285 Weight (lbs/1000 ft) Minimum Breaking Load (lbf) Short Time Fusing Current @ 30 Cycles kA Nominal DC Resistance @20ºC (Ω/1000 ft) in2 cmil 40%* COND 30%* COND 40%* COND 30%* COND 40%* COND 30%* COND 40%* COND 30%* COND 0.0130 16512 46.3 45.82 503 566 2.23 1.93 1.572 2.094 6 0.1620 0.0206 26250 73.6 72.8 800 900 3.55 3.07 0.989 1.317 4 0.2043 0.0328 41738 117.0 115.8 1272 1431 5.65 4.89 0.622 0.828 2 0.2576 0.0521 66368 186.1 184.1 2023 2275 8.98 7.77 0.391 0.521 *40% or 30% conductivity of IACS Stranded Constructions Size (AWG) # of Wires Diameter (inches) Cross Sectional Area Weight (lbs/1000 ft) Minimum Breaking Load (lbf) Short Time Fusing Current @ 30 Cycles kA Nominal DC Resistance @20ºC (Ω/1000 ft) in2 cmil 40%* COND 30%* COND 40%* COND 30%* COND 40%* COND 30%* COND 40%* COND 30%* COND 259 257 2513 2827 12.39 10.73 0.286 0.381 7 0.343 0.0720 91612 7 No. 8 7 0.386 0.0908 115586 327 324 3171 3567 15.63 13.54 0.227 0.302 2/0 7 0.410 0.1046 133115 377 373 3652 4108 18.01 15.59 0.197 0.262 7 No. 7 7 0.433 0.1145 145757 413 409 3998 4498 19.72 17.07 0.180 0.240 7 No. 6 7 0.486 0.1443 183708 520 515 5040 5670 24.85 21.52 0.143 0.190 7 No. 5 7 0.546 0.1819 231613 656 649 6354 7148 31.33 27.13 0.113 0.151 4/0 19 0.530 0.1661 211475 601 595 5801 6526 28.60 24.77 0.124 0.166 19 No. 9 19 0.572 0.1953 248660 707 700 6821 7674 33.63 29.13 0.106 0.141 19 No. 8 19 0.643 0.2464 313733 892 883 8606 9682 42.44 36.75 0.084 0.112 *40% or 30% conductivity of IACS 42 Proof PositivE® Copper-CLAD STEEL 7 No. 9 Grounding & Bare Copper 8 Diameter (inches) Cross Sectional Area