ELECTRICAL SYMBOLS FLOOR OUTLET / DEVICES AND SHOWN SMOKE DETECTOR -RESIDENTIAL RANGE OUTLET TRACK LIGHTING UNIT RECESSED DOWNLIGHT WALLWASH / FLOOD CEILING MOUNTED EXIT SIGN WALL MOUNTED EXIT SIGN EMERGENCY LIGHTING UNIT W/ HEADS RECESSED REMOTE HEAD WALL MOUNTED REMOTE HEAD EMERGENCY LIGHTING UNIT W/O HEADS CONTROL SINGLE POLE TOGGLE SWITCH JUNCTION BOX STROBE UNIT ( VISIBLE ONLY ) HORN UNIT ( AUDIBLE ONLY ) WALL SPEAKER* RECESSED CEILING SPEAKER GUEST ROOM DEVICE - HORN / SMOKE DETECTOR VOLUME CONTROL* PULL STATION TELEVISION OUTLET* FIRE ALARM CONTROL PANEL COMMUNICATIONS* BELL / BUZZER DOUBLE POLE TOGGLE SWITCH MOMENTARY CONTACT SWITCH SPEED CONTROL SWITCH PUSH BUTTON DIMMER 3-WAY DIMMER ELECTRIC THERMOSTAT GUEST ROOM DEVICE - HORN / STROBE / SMOKE DETECTOR MICROPHONE OUTLET* 4-WAY TOGGLE SWITCH KEYED SWITCH HORN STROBE UNIT ( AUDIBLE & VISIBLE ) CLOCK OUTLET (UNLESS SPECIFIED WIRELESS) WALL MOUNTED TELEPHONE OUTLET* SWITCH WITH PILOT BEAM DETECTOR TRANSMITTER/RECEIVER WALL MOUNTED JUNCTION BOX 3-WAY TOGGLE SWITCH SWITCH WITH TIMER DUCT MOUNTED SMOKE DETECTOR / DAMPER CONTROL AUNNUNCIATOR SPRINKLER FLOW SWITCH SPRINKLER TAMPER SWITCH VICTORIA CITY HALL FFE = 974.0 MAGNETIC DOOR HOLD OPEN MISCELLANEOUS DEVICES MOUNTED IN COMMON OUTLET MOTOR CONTROLLER COMBINATION MOTOR CONTROLLER / DISCONNECT T SMOKE DAMPER CARBON MONOXIDE DETECTOR AREA OF RESCUE AIL DISCONNECT SWITCH R ET PANEL - REFER TO SCHEDULE Y NT TERMINAL CABINET CO N I P MOTOR BIK U E HE NN PROPOSED TRANSFORMER I hereby certify that this plan, specification, or report was pre-pared by me or under my direct supervision and that i am a duly registered Engineer under the laws of the state of Minnesota. Kaeko Leitch Reg. No.: ) AK RL GE TEI ANE EL Date: S 3 ( ABBREVIATIONS .N . RD CO 1 O. 1 This document is by Brunton Architects and contains privileged and confidential information intended for use by Brunton Architects personnel only. Any disclosure or distribution of this document or information contained herein, without prior written consent of Brunton Architects, is prohibited. S 1 E0.1 SITE PLAN - ELECTRICAL SCALE: 1" = 20'-0" 20 SCALE 0 20 NORTH FEET PLAN NOTES 1. PROVIDE (2) 4" SCHEDULE 40 PVC CONDUITS FROM TELEPHONE BACKBOARD TO PROPERTY LINE , CAP AND STAKE. BURY CONDUIT 30" BELOW GRADE, 3'-0" SWEEPS, NO ELECTRICAL BENDS ALLOWED. BORE CONDUITS UNDER CO. RD. 113 TO APPROXIMATE LOCATION SHOWN. FIELD VERIFY EXACT LOCATION WITH TELEPHONE UTILITY. REVISIONS: 2. NEW 800A SERVICE. E.C. TO PROVIDE CONDUITS AND CONDUCTORS AS REQUIRED. BORE FEEDERS UNDER CO. RD. 113 AS REQUIRED TO MAKE CONNECTION TO UTILITY TRANSFORMER. 3. 200A/2P FEEDER TO BAND SHELTER, APPROXIMATELY 150 FEET. FIELD VERIFY EXACT LOCATION WITH OWNER AND OR ARCHITECT PRIOR TO INSTALLATION. BAND SHELTER PANEL PROVIDED AND INSTALLED BY OTHERS. SHEET NO. E0.1 DATE: SURFACE FLUORESCENT, NIGHT LIGHT / EMERGENCY DUCT SMOKE DETECTOR PROJECT MANAGER: SURFACE FLUORESCENT HALF SWITCHED DUPLEX RECEPTACLE GFCI PROTECTED OUTLET WEATHER PROOF & WEATHER RESISTANT OUTLET SPECIAL PURPOSE OUTLET CHECKED BY: RECESSED FLUORESCENT, NIGHT LIGHT / EMERGENCY THERMAL HEAT DETECTOR - FIXED TEMPERATURE DRAWN BY: RECESSED FLUORESCENT QUAD-PLEX RECEPTACLE THERMAL HEAT DETECTOR -RATE OF RISE FOX/BJB WALL MOUNTED FIXTURE NIGHT LIGHT / EMERGENCY DUPLEX RECEPTACLE PHOTOELECTRIC SMOKE DETECTOR SITE PLAN - ELECTRICAL WALL MOUNTED FIXTURE DEVICES CONSULTANT RECESSED DOWNLIGHT, NIGHT LIGHT / EMERGENCY FIRE ALARM PROJECT: RECESSED DOWNLIGHT PLAN NOTE PROJECT NUMBER: SURFACE FIXTURE, NIGHT LIGHT / EMERGENCY MOTOR DESIGNATION - REFER TO SCHEDULE SHEET TITLE: SURFACE FIXTURE PHOTO ELECTRIC CONTROL NURSE CALL INTERCOM CARD READER OCCUPANCY SENSOR QUAMOCLIT STREET LIGHTING FIXTURES LIGHT FIXTURE TYPE - REFER TO SCHEDULE F WORKROOM 109 LIBRARY 106 ELEC. 108 JANITOR 103 E IT 110 ELEV. EQUIP 105 MEN 102 D RECESSED LIGHT FIXTURE SUPPORT DETAIL SPRINKLER 104 NO SCALE WOMEN 101 EMERGENCY CONTROL DEVICE DETAIL LOBBY 100 WEST STAIR 107 N.T.S. STOR. 111 C BOOK DROP 112 B EAST STAIR 113 CONSULTANT A 1 2 2.9 3 3.9 4 4.6 5 6 7 I hereby certify that this plan, specification, or report was pre-pared by me or under my direct supervision and that i am a duly registered Engineer under the laws of the state of Minnesota. Kaeko Leitch Reg. No.: Date: 1 E1.1 LIGHTING CONTROL PANEL LCP-01 FIRST FLOOR PLAN - LIGHTING 8 SCALE: 1/8" = 1'-0" 0 8 NORTH This document is by Brunton Architects and contains privileged and confidential information intended for use by Brunton Architects personnel only. Any disclosure or distribution of this document or information contained herein, without prior written consent of Brunton Architects, is prohibited. N.T.S. SCALE FEET F BREAK RM. 216 CONF. RM. 202 WEST STAIR 206 UNISEX RESTROOM 215 SERVER ROOM 214 E LIGHTING CONTROL PANEL LCP-02 COUNCIL CHAMBERS 203 N.T.S. RECEPTION 212 PLAN NOTES AV RM. 201 GENERAL NOTES LOBBY 200 6. LIGHTING IN THIS AREA TO BE CONTROLLED VIA DIMMABLE DAYLIGHT HARVESTING. SUPPLIER AND/OR MANUFACTURER TO DETERMINE MOUNTING LOCATIONS AND QUANTITIES. SEE NOTE 7. OFFICE 209 OFFICE 210 ADMIN. OFFICE 211 A F. A NUMBER NEXT TO A LIGHT FIXTURE REPRESENT THE CIRCUIT NUMBER. THE LETTER NEXT TO A LIGHT FIXTURE IS THE SWITCH DESIGNATION. 1 1.2 2 2.9 3 3.9 4 4.6 5 6 6.8 7 7. LCD-203 DIMMING DAYLIGHT HARVESTING SYSTEM. BT-203 POWER PACK HAS (3) NORMALLY OPEN RELAYS, 620VA, AT 120 OR 277 VAC. POWER PACKS ARE USED TO INCREASE LOAD CAPACITY TO 20A IN EACH ZONE. VERIFY PLACEMENT OF DEVICES WITH FACTORY. MANUFACTURER - WATTSTOPPER. LS-5C SWITCH. 8. ROUTE HOME RUN THRU LIGHTING CONTROL LCP-01. SEE DETAIL THIS SHEET. 9. RECESSED GROUND MOUNTED FLAG FLOOD LIGHT. MOUNT FLOOD 36" FROM FLAG POLE. 10. ROUTE HOME RUN THRU LIGHTING CONTROL PANEL LCP-02. SEE DETAIL THIS SHEET. 2 E1.1 SECOND FLOOR PLAN - LIGHTING SCALE: 1/8" = 1'-0" 8 SCALE 0 8 FEET NORTH SHEET NO. E1.1 DATE: OFFICE 208 CONF. RM. 207 PROJECT MANAGER: B CHECKED BY: E. CONCEAL RACEWAY WHERE EVER POSSIBLE. WHEN EXPOSED RACEWAY MUST BE USED IN FINISHED AREAS, IT SHALL BE A SURFACE RACEWAY SYSTEM SUCH AS PANDUIT OR WIREMOLD, PER SPEC SECTION 26 05 33. C FOX/BJB 5. LIGHTING IN THIS AREA TO BE CONTROLLED VIA COMBINATION OCCUPANCY SENSOR(S), WALL SWITCH AND DIMMABLE DAYLIGHT HARVESTING. SUPPLIER AND/OR MANUFACTURER TO DETERMINE MOUNTING LOCATIONS AND QUANTITIES. SEE NOTE 7. D. WHEN NOTED "EQUAL MANUFACTURE", "OR EQUAL", "APPROVED EQUAL", OR OTHER SIMILAR TERMS, IT IS UNDERSTOOD TO MEAN THE ENGINEER'S AND ARCHITECT'S APPROVAL. HAVING PRIOR APPROVAL ON A MANUFACTURE ONLY, DOES NOT RELIEVE THE MANUFACTURE OF MEETING WHAT IS SPECIFIED. THE FINAL ACCEPTANCE OR REJECTION WILL BE BASED ON REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER AND ARCHITECT. DRAWN BY: 4. 2000W, 120V EMERGENCY LIGHTING INVERTER PROVIDED AND INSTALLED BY DIV. 26. SURE-LITES CFMT020. REVISIONS: C. ELECTRICAL CONTRACTOR TO UPDATE PANEL INDEXES UPON COMPLETION. FIRST AND SECOND FLOOR LIGHTING 3. THIS LIGHT CONNECTED THRU WATTSTOPPER ELCU EMERGENCY CONTROL DEVICE. SEE DETAIL THIS SHEET. SUPPLIER AND/OR MANUFACTURER TO DETERMINE MOUNTING LOCATIONS AND QUANTITIES ROOF ACCESS 205 B. REUSE EXISTING RACEWAY WHENEVER POSSIBLE. PROJECT NUMBER: 2. LIGHTING IN THIS ROOM TO BE CONTROLLED VIA COMBINATION OCCUPANCY SENSOR(S) AND LIGHT SWITCHES. SUPPLIER AND / OR MANUFACTURE TO DETERMINE MOUNTING LOCATIONS & QUANTITIES. A. PROVIDE A CONSTANT HOT TO ALL NIGHT LIGHTS, EXIT SIGNS, & EMERGENCY LIGHTS. SHEET TITLE: 1. LIGHTING IN THIS ROOM TO BE CONTROLLED BY OCCUPANCY SENSOR(S). SUPPLIER AND/ OR MANUFACTURE TO DETERMINE MOUNTING LOCATIONS & QUANTITIES. PROJECT: EAST STAIR 213 GENERAL NOTES PLAN NOTES A. COORDINATE RECEPTACLE HEIGHTS ABOVE OR IN CABINETS WITH ARCHITECTURAL PLANS. 1. DUAL CHANNEL ALUMINUM POWER POLE, PANDUIT PCPA. E.C. TO PROVIDE AND INSTALL POLE AND MAKE 120V CONNECTION TO OWNER SUPPLIED FURNITURE. B. ELECTRICAL CONTRACTOR TO UPDATE PANEL INDEXES UPON COMPLETION. 2. MULTI-SERVICE FLUSH FLOOR BOX PROVIDED AND INSTALLED BY E.C. WITH DEVICES AS INDICATED. WIREMOLD RFB4. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. D. AMOUNT AND PLACEMENT OF NAC PANELS ARE TO BE DETERMINED BY THE FIRE ALARM EQUIPMENT SUPPLIER. EACH NAC PANEL IS TO HAVE A SMOKE DETECTOR WITHIN 5' OF THE PANEL. E. REMOTE TEST SWITCHES FOR DUCT SMOKE DETECTORS ARE TO BE GROUPED IN A READILY ACCESSIBLE LOCATION IN EACH AREA. F. MAKE 120V CONNECTION TO SMOKE FIRE DAMPERS. DAMPERS TO LOOSE POWER UPON ACTIVATION OF FIRE ALARM SYSTEM. DAMPERS TO BE POWERED OPEN WHEN FIRE ALARM PANEL HAS BEEN RESET. G. WHEN NOTED "EQUAL MANUFACTURE", "OR EQUAL", "APPROVED EQUAL" OR OTHER SIMILAR TERMS, IT IS UNDERSTOOD TO MEAN THE ENGINEER'S AND ARCHITECT'S APPROVAL. HAVING PRIOR APPROVAL ON A MANUFACTURE ONLY, DOES NOT RELIEVE THE MANUFACTURE OF MEETING WHAT IS SPECIFIED. THE FINAL ACCEPTANCE OR REJECTION WILL BE BASED ON REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER AND ARCHITECT. H. CONCEAL RACEWAY WHERE EVER POSSIBLE. WHEN EXPOSED RACEWAY MUST BE USED IN FINISHED AREAS, IT SHALL BE A SURFACE RACEWAY SYSTEM SUCH AS PANDUIT OR WIREMOLD, PER SPEC SECTION 26 05 33. 4. FIELD VERIFY EXACT TV DEVICE AND RECEPTACLE MOUNTING HEIGHT AND LOCATION WITH OWNER PRIOR TO INSTALLATION. E 6. E.C. TO PROVIDE AND INSTALL SWITCHED GFCI RECEPTACLE UNDER SINK FOR DISPOSAL. DISPOSAL PROVIDED AND INSTALLED BY OTHERS. WORKROOM 109 ELEV. EQUIP 105 ELEC. 108 7. MULTI-OUTLET ASSEMBLY (PANDUIT T-70) MOUNTED AT APPROXIMATELY 18" A.F.F. WITH DEVICES AS INDICATED, UNLESS NOTED OTHERWISE. DEVICES AND COVERPLATES TO BE OF SAID MANUFACTURER SO THAT COLOR OF DEVICES AND RACEWAY MATCH. MEN 102 D STOR. 111 WOMEN 101 WEST STAIR 107 9. 12"L, 4"H, 1/4" THICK COPPER BUS BAR WITH (1) #6 BARE GROUND BACK TO MDP-1. PROVIDED AND INSTALLED BY E.C. J. CHECKOUT & START UP OF VFD'S ARE BY DIV. 23. 11. DEVICES TO BE MOUNTED IN BACK OF CABINET. FIELD VERIFY EXACT MOUNTING REQUIREMENTS WITH CABINET SUPPLIER. 12. E.C. TO PROVIDE AND INSTALL (2) 4" EMT CONDUITS FROM SERVER ROOM 214 TO CEILING SPACE IN IT 110 FOR COMMUNICATIONS CABLES. STUB CONDUITS 4" A.F.F. PROVIDE BUSHINGS ON BOTH ENDS. CONCEAL ALL CONDUITS. 13. E.C. TO MAKE 120V POWER CONNECTION TO AUTO DOOR. DOOR PROVIDED AND INSTALLED BY OTHERS. IT 110 SPRINKLER 104 8. ALL 120V, 20A DUPLEX RECEPTACLES IN BREAK ROOM TO BE GFCI MOUNTED AT 44" A.F.F. UNLESS OTHERWISE NOTED. 10. FLOOR BOX PROVIDED AND INSTALLED BY E.C. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. STEEL CITY 665-AV2 FLOOR BOX. L. ELECTRICAL CONTRACTOR SHALL SIZE CONDUCTORS AS REQUIRED BY N.E.C. FOR VOLTAGE DROP COMPENSATION. JANITOR 103 5. MAKE 120V CONNECTION TO DISHWASHER, CORD PROVIDED WITH UNIT INSTALLED BY E.C. I. IN RACEWAYS WITH MULTIPLE CIRCUITS, THE NUMBER NEXT TO THE RECEPTACLE INDICATES THE CIRCUIT NUMBER. A SEPARATE NEUTRAL IS TO BE INSTALLED FOR EACH HOMERUN. K. ALL SPECIAL SYSTEM CABLES TO BE RAN IN A RACEWAY UNLESS INSTALLED ABOVE ACCESSIBLE CEILINGS. LIBRARY 106 3. E.C. TO MAKE 120V POWER CONNECTION TO HAND DRYER. DRYER PROVIDED AND INSTALLED BY OTHERS. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT PRIOR TO INSTALLATION. LOBBY 100 C BOOK DROP 112 B EAST STAIR 113 A CONSULTANT C. EACH RECEPTACLE DESIGNATED GFCI IS TO HAVE A TEST & RESET BUTTON WITHIN SIGHT OF THE RECEPTACLE. F 14. E.C. TO PROVIDE AND INSTALL (1) 3/4" CONDUIT BETWEEN COMMUNICATIONS PORTIONS OF FLOOR BOXES. 1. INSTALL SWITCH, LIGHT AND GFCI RECEPTACLE IN ELEVATOR PIT NEAR ACCESS. 2. 60A, 1 PH. PANEL ELEV-1 FOR ELEVATOR RELATED ELECTRICAL DEVICES. SEE PANEL SCHEDULE. 16. E.C. TO PROVIDE AND INSTALL (2) 4" EMT CONDUITS FROM TELEPHONE BOARD TO SERVER ROOM 214 FOR COMMUNICATIONS CABLES. STUB CONDUITS 4" A.F.F. PROVIDE BUSHINGS ON BOTH ENDS. CONCEAL ALL CONDUITS. 3. INSTALL 120V FROM LIGHTED KEYED SWITCH AT FIRST LEVEL UP TO MOTORIZED DAMPER AT TOP OF ELEVATOR SHAFT ABOVE ROOF. VERTICAL DISTANCE APPROXIMATELY 40'-0". E.C. TO INTERLOCK FIRE DAMPER AT TOP OF ELEVATOR SHAFT WITH LIGHTED SWITCH AT ELEVATOR LOBBIES SO THAT INDICATOR LIGHT COMES ON WHEN DAMPER REACHES 80% OPEN. FLUSH MOUNTED SWITCH PROVIDED AND INSTALLED BY E.C., DAMPER BY OTHERS. 17. E.C. TO PROVIDE AND INSTALL 4' x 4' x 3/4" AD PLYWOOD BACKBOARD PAINTED WITH 3 COATS FIRE RETARDANT PAINT. DOUBLE DUPLEX RECEPTACLE FOR EQUIPMENT POWER, GROUND AS REQUIRED. (2) 4" SCHEDULE 40 PVC CONDUITS FROM TELEPHONE BACKBOARD TO LOCATION SHOWN ON SHEET E0.1, CAP AND STAKE. BURY CONDUIT 30" BELOW GRADE, 3'-0" SWEEPS, NO ELECTRICAL BENDS ALLOWED. 4. ADDRESSABLE SMOKE DETECTOR W/ ADDRESSABLE BASE AT THE ELEVATOR LOBBIES. CONNECT TO FIRE ALARM CONTROL PANEL. 18. FLOOR BOX PROVIDED AND INSTALLED BY E.C. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. STEEL CITY 665-AV2 FLOOR BOX. E.C. TO MAKE 120V CONNECTION TO OWNER SUPPLIED FURNITURE. 5. ELEVATOR CONTROLLER. 6. ELEVATOR MACHINE - 208V, 3-PHASE, 25 HP. 7. 200A FUSIBLE ELEVATORBDISCONNECT SWITCH W/ AUXILIARY CONTACTS. FUSE SIZE TO BE COORDINATED W/ FEEDER OVERCURRENT DEVICE SO AS TO TRIP BEFORE FEEDER PROTECTION. COORDINATE W/ EQUIPMENT SUPPLIER REGARDING NAMEPLATE REQUIREMENTS. AUXILIARY CONTACTS ARE FOR CONNECTING THE EMERGENCY BATTERY LOWERING IF SUPPLIED W/ELEVATOR. 8. EXTEND CIRCUITS TO ELECTRIC PANEL IN THE ELEVATOR EQUIPMENT ROOM, INSTALL (4) 20A, SINGLE-POLE CIRCUIT BREAKERS FOR THE FAN AND LIGHTING, RECEPTACLE IN THE ELEVATOR PIT, RECEPTACLE IN THE ELEVATOR ROOM, AND FOR THE LIGHTS IN THE ELEVATOR CAR. PROVIDE (1) 110A, 3-POLE CIRCUIT BREAKER FOR ELEVATOR MACHINE. 9. INSTALL INSIDE OF CONTROL PANEL DISCONNECT LOCKABLE IN "OFF" POSITION FOR CAR/FAN LIGHT CIRCUIT. 10. EXHAUST FAN CONTROLLED BY REVERSE ACTING T'STAT. 11. E.C. TO PROVIDE AND INSTALL RACEWAY AND CAT 5E CABLE FROM ELEVATOR CONTROL PANEL BACK TO TELEPHONE BACKBOARD. 12. ADDRESSABLE SMOKE DETECTOR W/ ADDRESSABLE & W/ RELAY BASE IN ELEVATOR EQUIPMENT ROOM. CONNECT TO 120V LEG OF SMOKE/FIRE DAMPERS IN ELEVATOR EQUIPMENT ROOM AND TO FIRE ALARM CONTROL PANEL. 13. ADDRESSABLE CONTROL MODULE WITHIN 36" OF ELEVATOR SHUNT TRIP CIRCUIT BREAKER. CONNECT TO FIRE ALARM CONTROL PANEL AND TO ELEVATOR SHUNT TRIP CIRCUIT BREAKER. I hereby certify that this plan, specification, or report was pre-pared by me or under my direct supervision and that i am a duly registered Engineer under the laws of the state of Minnesota. 15. E.C. TO PROVIDE AND INSTALL (1) 2" EMT CONDUITS FROM SERVER ROOM 214 TO CEILING SPACE IN IT 110 FOR COMMUNICATIONS CABLES. STUB CONDUITS 4" A.F.F. PROVIDE BUSHINGS ON BOTH ENDS. CONCEAL ALL CONDUITS. 1 2 2.9 3 3.9 4 4.6 5 6 7 Kaeko Leitch Reg. No.: FIRST FLOOR PLAN - POWER 1 E2.1 Date: 8 SCALE: 1/8" = 1'-0" 0 SCALE 8 NORTH This document is by Brunton Architects and contains privileged and confidential information intended for use by Brunton Architects personnel only. Any disclosure or distribution of this document or information contained herein, without prior written consent of Brunton Architects, is prohibited. FEET 19. (1) 2" CONDUIT FROM FLOOR BOX TO BACKBOARD LOCATED IN IT ROOM. CONCEAL ALL CONDUIT, PROVIDE AND INSTALL BUSHINGS AS REQUIRED. STUB CONDUITS UP 4" A.F.F. FLOOR BOX PROVIDED AND INSTALLED BY E.C. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. STEEL CITY 665-AV2 FLOOR BOX. 20. CEILING FAN PROVIDED AND INSTALLED BY DIV. 26. BIG ASS FANS ISIS IS08, 120V, SINGLE-PHASE, 10A WITH CONTROLLER. 21. PROVIDE RECEPTACLE FOR MICROWAVE. VERIFY EXACT MOUNTING HEIGHT WITH ARCHITECT AND OR OWNER PRIOR TO INSTALLATION. F CONF. RM. 202 22. E.C. TO PROVIDE AND INSTALL FLIP UP, TABLETOP UNIT. ELECTI- CABLE ASSEMBLIES INTERACT JR, BRUSH ALUMINUM FINISH. VERIFY EXACT LOCATION WITH ARCHITECT AND OR OWNER PRIOR TO INSTALLATION. (2) POWER,(2) DATA, 72" POWER CORD PROVIDED WITH UNIT. BREAK RM. 216 WEST STAIR 206 UNISEX RESTROOM 215 23. E.C. TO PROVIDE AND INSTALL (1) 1" CONDUIT FROM FLOOR BOX TO TV BOX. CONCEAL ALL CONDUIT, PROVIDE AND INSTALL BRUSHING AS REQUIRED. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. CONCEAL ALL CONDUIT. 24. E.C. TO PROVIDE AND INSTALL (1) 3" EMPTY CONDUIT FROM LOCATION SHOWN TO AV ROOM 201. STUB CONDUITS UP 4" AF.F. FIELD VERIFY EXACT LOCATIONS WITH OWNER PRIOR TO INSTALLATION. SERVER ROOM 214 E COUNCIL CHAMBERS 203 25. E.C. TO MAKE 120V POWER CONNECTION TO EXTERIOR CABINET. CABINET PROVIDED AND INSTALLED BY OTHERS. ROUTE HOME FUN THRU LCP-01. FIELD VERIFY EXACT LOCATION, MOUNTING HEIGHT, AND POWER REQUIREMENTS WITH OWNER AND OR ARCHITECT. EAST STAIR 213 AV RM. 201 LOBBY 200 PROJECT: ELEVATOR PLAN NOTES RECEPTION 212 14. ADDRESSABLE PRIMARY AND ALTERNATE CONTROL MODULES WITHIN 36" OF ELEVATOR CONTROLLER. CONNECT TO FIRE ALARM CONTROL PANEL AND TO THE ELEVATOR CONTROLLER. CONNECTIONS TO ELEVATOR CONTROLLER BY ELEVATOR INSTALLER. REVISIONS: ROOF ACCESS 205 1 3 E2.1 SPECIAL SYSTEMS OUTLET ENLARGED ELEVATOR PLAN - ELECTRICAL SCALE: 1/4" = 1'-0" 4 SCALE 0 4 FEET NORTH 1.2 2 2.9 3 3.9 2 E2.1 4 4.6 5 SECOND FLOOR PLAN - POWER SCALE: 1/8" = 1'-0" 8 SCALE 0 8 NORTH 6 6.8 7 FEET SHEET NO. NO SCALE E2.1 DATE: CHECKED BY: DRAWN BY: A FOX/BJB CONF. RM. 207 OFFICE 210 FIRST AND SECOND FLOOR POWER AND SPECIAL SYSTEMS B OFFICE 209 PROJECT NUMBER: OFFICE 208 SHEET TITLE: ADMIN. OFFICE 211 PROJECT MANAGER: C CONSULTANT I hereby certify that this plan, specification, or report was pre-pared by me or under my direct supervision and that i am a duly registered Engineer under the laws of the state of Minnesota. Kaeko Leitch Reg. No.: Date: This document is by Brunton Architects and contains privileged and confidential information intended for use by Brunton Architects personnel only. Any disclosure or distribution of this document or information contained herein, without prior written consent of Brunton Architects, is prohibited. ELECTRICAL POWER RISER DIAGRAM N.T.S. FIRE ALARM RISER DIAGRAM N.T.S. PLAN NOTES PROJECT: 1. CABLE TRAY. SEE SPECIFICATIONS FOR REQUIREMENTS. CABLE TRAY PROVIDED AND INSTALLED BY DIV. 26. REVISIONS: F D C C B A B A 1 1.2 2 2.9 3 3.9 4 5 6 6.8 2 2.9 3 3.9 4 4.6 5 6 7 DOOR ENTRY DETAIL 7 N.T.S. 1 E3.1 ROOF PLAN - ELECTRICAL SCALE: 1/16" = 1'-0" 16 SCALE 0 16 FEET NORTH 2 E3.1 FIRST FLOOR PLAN - CABLETRAY SCALE: 1/16" = 1'-0" 16 SCALE SHEET TITLE: 1 ELECTRICAL POWER RISER DIAGRAM FIRE ALARM RISER DIAGRAM ROOF PLAN - ELECTRICAL D SHEET NO. 0 16 FEET NORTH E3.1 DATE: PROJECT MANAGER: CHECKED BY: E DRAWN BY: E FOX/BJB PROJECT NUMBER: F CONSULTANT I hereby certify that this plan, specification, or report was pre-pared by me or under my direct supervision and that i am a duly registered Engineer under the laws of the state of Minnesota. Kaeko Leitch Reg. No.: Date: PROJECT: This document is by Brunton Architects and contains privileged and confidential information intended for use by Brunton Architects personnel only. Any disclosure or distribution of this document or information contained herein, without prior written consent of Brunton Architects, is prohibited. SHEET NO. E3.2 DATE: PROJECT MANAGER: CHECKED BY: DRAWN BY: FOX/BJB ELECTRICAL SCHEDULES SHEET TITLE: PROJECT NUMBER: REVISIONS: