LED EXIT SIGN/EMERGENCY LIGHT WITH - E

advertisement
LED EXIT SIGN/EMERGENCY LIGHT
WITH BATTERY BACKUP
(E-XMD SERIES)
Applications: For general purpose emergency lighting in commercial, retail or industrial applications.
16-5/16"
15-5/8"
4/5/8"
5-7/8"
10-1/8"
21-5/8"
1"
Canopy
Red Letters
Green Letters
Letters on sign face are 6" high
Catalog #
Description
Input
Voltage
Ambient
Temperature
Rating
Weight
Lamp (included)
E-XMDRB2W
LED Exit sign/emergency light
w/battery backup
(red letters)
120- or 277-volt
50˚F to 104˚F
8.6 lbs
Two 180-degree adjustable T5
wedge base lighting heads,
6-volts, 5.4 watts each
E-XMDGB2W
LED Exit sign/emergency light
w/battery backup (green letters)
120- or 277-volt
50˚F to 104˚F
8.6 lbs
Two 180-degree adjustable T5
wedge base lighting heads,
6-volts, 5.4 watts each
E-XMDRB2RCW
LED Exit sign/emergency light
w/battery backup/remote capable
(red letters)
120- or 277-volt
50˚F to 104˚F
10.2 lbs
Two 180-degree adjustable T5
wedge base lighting heads,
6-volts, 5.4 watts each
E-XMDGB2RCW
LED Exit sign/emergency light
w/battery backup/remote capable
(green letters)
120- or 277-volt
50˚F to 104˚F
10.2 lbs
Two 180-degree adjustable T5
wedge base lighting heads,
6-volts, 5.4 watts each
Performance
Electrical
• 1-year limited warranty
•
•
•
•
•
•
•
•
•
•
•
•
Construction & Materials
White housing
Single/Double face easily converts from double to single face.
Blank face included for single face installations
Sealed, maintenance-free lead-calcium battery provides (90 min.)
of emergency operation
Easy to remove and replace chevrons
Wall mountable/includes canopy for top mounting
Push-to-test switch
Charge/power-on indicator light
Long Life LED
Remote capable models can accommodate up to 12 watts, 6-volts
Automatic low-voltage disconnect and brownout protection
Injection molded, UL94V-0 flame retardant, ABS virgin plastic housing
Labor saving AC line latching
Regulatory
• Listed and complies with UL924
• Complies with NFPA 101 Life Safety Code
• Suitable for use in damp locations
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
LED EXIT SIGN/EMERGENCY LIGHT
WITH BATTERY BACKUP
(E-XMD SERIES)
Accessories (for remote capable only)
6-V Single Remote heads:*
6-V Dual Remote heads:*
5.4-watt (dry listed)
• White
CAT.# E-XHS0506DW
5.4-watt (dry listed, 10.8-watts total)
• White
CAT.# E-XH20506W
9-watt (dry listed)
• White
CAT.# E-XHS0906DW
5.4-watt (wet listed)
• White
CAT.# E-XHS0506WW
5.4-watt (wet listed, 10.8-watts total)
• White
CAT.# E-XHD0506WW
9-watt (wet listed)
• White
CAT.# E-XHS0906WW
*For voltage drop information see www.e-conolight.com/pdf/Instructions/VOLTCHART.PDF
Due to continuous product improvement, information in this document is subject to change. All published photometric testing performed to IESNA LM-79-08
standards by a NVLAP certified laboratory. Fixture photometry was completed on a single representative fixture. Actual production units may vary up to
±10% of initial delivered lumens. Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ fixture testing.
1501 96th Street, Sturtevant, WI 53177 | Phone (888)243-9445 | Fax (262)504-5409 | www.e–conolight.com
Download